"LongLifeSwitching" Technology Is switching in the data center risky? No, switching functions protect your service and increase availability! 1. Disconnected, unused outlets prevent unintentional overloading. 2. Selective emergency shutdown saves your business in the worst-case scenario 3. Almost powerless switching protects your data center equipment. Are the points listed above important to you? Then please read on... If so, then you should be using the MPH2™ Rack PDU (Power Distribution Unit) with its unique "LongLifeSwitching" technology to prevent failure of your power supply. What does "LongLifeSwitching" mean exactly? "Bi-stable relays" with high-quality switching contacts ensure the basic supply of power even in the event of disturbances elsewhere. "Bi-stable relays" do not use power when they are in an ON or OFF state and can therefore achieve energy savings of up to 75 %. Powerless, zero-crossing switching protects the relay contacts, failures are avoided, and the life cycle of the data center equipment (servers, PDUs, etc.) is extended. In the event of a power failure, the outlets are automatically set to "OFF". This prevents high inrush currents when the power supply is resumed. Circuit breakers – upstream or in the PDU – are not tripped. Furthermore, it also offers you additional functions in combination with the switching function: When a pre-set, adjustable threshold value is exceeded, pre-defined outlets are switched off. This leaves more power for the critical power consumers in the data center. As a result, critical IT services "survive" the worst-case scenario. Temperature sensors can be configured in such a way that pre-defined outlets switch off automatically at high temperatures. The switching status can be freely configured for each outlet in the event of a power failure (ON, OFF, "as before"). "LongLifeSwitching" Technology The MPH2™ PDUs listed below are available immediately! Locations By increasing the stock at our site in Germany, we are in a position to deliver the following MPH2™ models quickly. Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA T +1 614 8880246 MPH2™ types: MPH2™ B – input measurement MPH2™ C – input measurement and output switching MPH2™ M – input measurement and output measurement MPH2™ R – input measurement, output measurement, and output switching Type Input Values Input Plug Voltage Current B 230 V 16 A B 230 V 32 A Outlets Lengths Order Number C13 C19 (mm) C20 inlet 17 2 916.5 MPHB3241 IEC 60309 32 A 1P+N+G 30 6 1736.5 MPHB1243 B 230/400 V 3 x 16 A IEC 60309 16 A 3P+N+G 30 6 1736.5 MPHB1244 B 230/400 V 3 x 32 A IEC 60309 32 A 3P+N+G 30 6 1826.5 MPHB1245 C 230 V 16 A C20 inlet 16 1004 MPHC3141 C 230 V 32 A IEC 60309 32 A 1P+N+G 18 6 1736.5 MPHC1143 C 230/400 V 3 x 16 A IEC 60309 16 A 3P+N+G 24 1736.5 MPHC1244 C 230/400 V 3 x 32 A IEC 60309 32 A 3P+N+G 18 M 230 V 16 A C20 inlet 16 M 230 V 32 A IEC 60309 32 A 1P+N+G 18 M 230/400 V 3 x 16 A IEC 60309 16 A 3P+N+G 24 M 230/400 V 3 x 32 A IEC 60309 32 A 3P+N+G 18 R 230 V 16 A C20 inlet 16 R 230 V 32 A IEC 60309 32 A 1P+N+G 18 R 230/400 V 3 x 16 A IEC 60309 16 A 3P+N+G 24 R 230/400 V 3 x 32 A IEC 60309 32 A 3P+N+G 18 6 6 736.5 MPHC1145 1004 MPHM3141 1736.5 MPHM1143 1736.5 MPHM1244 6 1736.5 MPHM1145 1004 MPHR3141 6 1736.5 MPHR1143 1736.5 MPHR1244 6 1736.5 MPHR1145 Emerson Network Power Europe Middle East And Africa Mariakirchener Strasse 38 94424 Arnstorf Germany T +49 8723 27 0 F +49 8723 27 154 knuerr@emerson.com Emerson Network Power United Kingdom George Curl Way Southampton SO18 2RY, UK T +44 (0)23 8061 0311 F +44(0)23 8061 0852 UK.Enquiries@Emerson.com While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. INFO Follow us on: You can find further product information and components on the Internet at: www.EmersonNetworkPower.eu Emerson. Consider it Solved, InstaRack, and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. All the other marks are the property of their respective owners. ©2015 Emerson Electric Co. 1101.150.132 MPH2