Miami Dade Building Code Compliance Office Notice of Acceptance Product Certification Updated: 6/09 Quality You Can Trust Since 1886... From North America’s Largest Roofing Manufactur Quality You Can Trust Since 1886... From North America’s Largest Roofing Manufacturer ™ I i I MIA M I'~~'~ MIAMI-DADECOUNTY, FLORIDA ...i_' METRO-DADE FLAGLER BUll..DING BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE GAF Materials Corporation 1361Alps Road. Wayne, NJ 07470 140WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 (NOA) SCOPE: This NOA is being issuedunderthe applicablerules andregulationsgoverningthe useof constructionmaterials. The documentationsubmittedhasbeenreviewedby Miami-DadeCountyProductControl Division andaccepted by the Board of RulesandAppeals(BORA) to be usedin Miami DadeCounty andother areaswhereallowedby the Authority Having Jurisdiction(AlD). This NOA shall not be valid after the expirationdatestatedbelow. The Miami-DadeCounty ProductControl Division (In Miami DadeCounty)and/orthe AHJ (in areasother thanMiami DadeCounty) reservethe right to havethis productor materialtestedfor quality assurancepurposes.If this productor materialfails to perfonn in the acceptedmanner,the manufacturerwill incur the expenseof suchtestingandthe AHJ may immediately revoke, modify, or suspendthe useof suchproductor materialwithin their jurisdiction. BORA reservesthe right to revoke this acceptance, if it is determinedby Miami-DadeCountyProductControl Division that this productor materialfails to meetthe requirementsof the applicablebuilding code. This productis approvedasdescribedherein,andhasbeendesignedto comply with the Florida Building Code, including the High Velocity HurricaneZone. DESCRIPTION: GAF Grand TimberlineTMShingle LABELING: Eachunit shall beara pennanentlabel with the manufacturer'snameor logo, city, stateand following statement:"Miami-DadeCounty ProductControl Approved",unlessotherwisenotedherein. RENEWAL of this NOA shall be consideredafter a renewalapplicationhasbeenfiled and therehasbeenno changein the applicablebuilding codenegativelyaffecting the perfonnanceof this product. TERMINATION of this NOA will occur after the expirationdateor if therehasbeena revision or changein the materials,use,and/ormanufactureof the productor process.Misuseof this NOA as an endorsementof any product,for sales,advertisingor any other purposesshall automaticallyterminatethis NOA. Failure to comply with any sectionof this NOA shall be causefor terminationand removalof NOA. ADVERTISEMENT: The NOA numberprecededby the words Miami-DadeCounty, Florida, and followed by the expiration datemay be displayedin advertisingliterature. If any portion of the NOA is displayed,then it shall be donein its entirety. INSPECTION: A copy of this entireNOA shall be providedto the userby the manufactureror its distributors and shall be availablefor inspectionat thejob site at the requestof theBuilding Official. This NOA consistsof pagesI through4. The submitteddocumentationwasreviewedby Mark A. Zehnal,CPRC 9 z :- .:;,-r ..: - . NOA No.:05-0426.02 Expiration Date: 08/17/10 Approval Date: 08/17/05 -;:40'" Page1 of4 .~':i\ ,cO!:!}i. ROOFING ASSEMBLY ApPROVAL Cateeorv: Sub-Cateeorv: Roofing 07310AsphaltShingles Materials Deck Type: Dimensional Wood 1. SCOPE This approvesGAF Grand TimberlineTMShingle as manufacturedby GAF Materials Corp describedin Section2 of this Notice of Acceptance. 2. PRODUCT DESCRIPTION Product Dimensions GAF GrandTimberlineTM 17" x 40" ~ Soecifications TAS 110 Product Description Fiberglasreinforcedheavy weight asphalt roof shingle,with a laminateprofile 3. EVffiENCE SUBMITTED: Test A!!ency Test Identifier ~ Test Name/Report PRI Asphalt Technologies TAS-100 GAF-058-02-01 10/24/04 PRI Asphalt Technologies ASTM D3462 GAF-059-02-01 09/02/04 TAS-107 04NK30546 03/10/05 UnderwritersLaboratories,Inc. 4. LIMITATIONS 4.1 Fire classificationis not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratingsof this product. 4.2 Shall not be installedon roof meanheightsin excessof 33 ft. 4.3 All productslisted herein shall have a quality assuranceaudit in accordancewith the Florida Building CodeandRule 9B-72 of the Florida AdministrativeCode. 5. INSTALLATION 5.1 Shinglesshall be installedin compliancewith RoofingApplication StandardRAS 115. 5.2 Flashingshall be in accordancewith Roofing ApplicationStandardRAS 115 5.3 The manufacturershallprovide clearly written applicationinstructions. 5.4 Exposureand courselayout shall be in compliancewith Detail' A " attached. 5.5 Nailing shall be in compliancewith Detail 'B', attached. 6. LABELING 6.1 Shingles shall be labeled with the Miami-Dade Logo or the wording "Miami-Dade County ProductControl Approved". 7. BUILDING PERMIT REQUIREMENTS 7.1 Application for building permit shall be accompanied by copiesof the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documentsrequiredby the Building Official or the applicablecodein order to properlyevaluatethe installationof this system. 9 , o~-< -- . - Expiration NOA No.:05-0426.02 Date: 08/17/10 Approval Date: 08/17/05 Page2 of 4 I 8. MANUFACTURINGPLANTS 8.1 Mt. Vernon,IN. DETAIL A 40" 7.6" typo NAILS 1" 1" r 17"" NAIL GUIDELINE - -.- - - - .- - -- - 9-1/8" - =t 7-1/2"EXPOSURE ~ GRANDTIMBERLINETM 9-"" "" -< .: ApprovalDate:08/17/05 -;:~ , I I' . Expiration NOA No.:05-0426.02 Date:08/17/10 '" Page30f4 DETAILB FULL SHINGLE FIFTH COURSE "" "" "" "" "" "" ( "" ,, /' "" "" J """ FOURTH COURSE '"" TRIM 22" 'v j "" "" ",," '"" TRIM is" THIRD COURSE , "'" "" 'v \ "" FULL SHINGLE TRIM 7-1/2" SECOND COURSE END OF TmS ACCEPTANCE 8 ::: : CO' , '" . Co - -;;J.,--< NOA No.:05-0426.02 ExpirationDate:08/17/10 Approval Date: 08/17/05 Page4 of 4