AC Power Protection for Business-Critical Continuity Liebert ITON CX Line-Interactive UPS Performance Power Protection for PC’s and Office Equipment The Liebert ITON CX is an economical line-interactive UPS that offers full-featured power protection for small office computers and electronic equipment. With it’s unique features and extraordinary performance not normally found in similar products in range. Designed with simple controls for easy operation, the Liebert ITON CX provides up to four minutes of back-up time at full load...more than enough time to Save work in process and shut down your connected equipment. ITON CX 1000 VA Liebert ITON CX UPS Supports your sensitive electronics with these standard Features Flexibility: • Available in 1000 VA @230 Vac • Four Battery Backed outlets, depending on model size • Buck and Boost Mode AVR for Voltage stabilization • Auto Restart while AC is recovering • OFF mode charging • Cold Start Function • Generator Compatible • User Replaceable batteries ® Reliability: • Excellent microprocessor control guarantees high reliability • Up to five minutes of battery backup time at half load • Advance early warning of UPS shutdown • Two Year Replacement warranty The Liebert ITON CX is ideally suited for: • Professional Desktop PC’s • Professional Workstations • Small Routers, Bridges And Hubs • Point-of-Sale Terminals • Other Sensitive Electronics Technical Specifications COUNTRY OFFICE MODEL Specification ITON CX 1000 VA. CAPACITY VA/W 1000 VA/600 Watt. 220/230/240 VAC Voltage INPUT 140-300 VAC Voltage Range 50 Hz (Auto Sensing) Frequency Range ±10% AC Voltage Regulation (Batt. Mode) 50 Hz ±1 Hz Frequency Range (Batt. Mode) OUTPUT Emerson Network Power (India) Private Ltd. Plot No. C-20, Road No. 19, Wagle Estate, Thane (W), Maharashtra - 400 604. India. Tel.: 91-22-33154400 Fax: 91-22-25828358 Email: marketing.india@emerson.com Toll Free No: 1800 209 6070 Typical 4-8 ms Transfer Time Simulated Sine Wave Waveform (Batt. Mode) 110% +/-10% Shutdown after 5 mins Overload Battery Type & Number 12 V/7 Ah x 2 Typical Recharge Time 4-6 hours up to 90% capacity Voice of Customers UPS Awards 2004-05 for Product Line & Customer Service Awards in IT, Telecom, Large Enterprise & Hospitals and Customer Service Leadership Award in BFSI 120 Watt SPS load 30 Min. BATTERY 180 Watt SPS load 20 Min. Battery Back up 2005 240 Watt SPS load 10 Min. 300 Watt SPS load 5 Min. TRANSFER TIME Typical Minimum line break without transfer to battery 4 msec Minimum line break for transfer to battery 4-13 msec. INDICATORS AC Mode Green lighting Battery Mode Green flashing Fault Red lighting Sounding every 10 seconds Battery Mode Sounding every second Low Battery ALARM Overload Sounding every 0.5 second Battery Replacements Sounding every 2 second Fault Continuously sounding PROTECTION Full Protection PHYSICAL Dimension, D X W X H (mm) Overload, discharge, and overcharge protection 320x130x182 7.8 kG Net Weight (kgs) ENVIRONMENT Best IT Hardware Company Maharashtra IT Award 2005-06 0-40 Deg C. Operating Environment Storage Temp -15° C to 50° C 0-90 % RH @ 0- 40°C (non-condensing) Humidity Less than 40dB Noise Level * Product specification are subjected to change without further notice. ** De-rating of the UPS need to be consider according to the input voltage condition. Emerson Network Power. EmersonNetworkPower.com The global leader in enabling business-critical continuity. AC Power Embedded Computing Outside Plant Racks & Integrated Cabinets Connectivity Embedded Power Power Switching & Controls Services DC Power Infrastructure Management & Monitoring Precision Cooling Surge Protection While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2013 Emerson Electric Co.