DC Power for Business-Critical Continuity™ Solar Sub Rack Key Features nAdd solar energy to an existing -48V DC power system nEasy deployment in existing cabinets nCompatible with existing batteries nReduces expenses related to electricity and/or diesel fuel Solar Sub Racks from Emerson Network Power enable NetSure™ DC power systems and existing -48V DC power systems to operate on solar energy. Description Add solar energy to an existing -48V DC power system by integrating the Solar Sub Rack into the existing cabinet. The desired output voltage from the sub rack is set in the controller and is independent from the DC power supply system controller. The Solar Sub Rack exists in two versions: • Main unit with controller and space for one 3 kW solar converter module • Extension unit with space for two 3 kW solar converter modules Extension sub racks are connected to the main sub rack via CAN bus, allowing communication between the solar converters in the extension sub rack and the controller in the main sub rack. Extension sub racks can also be connected directly to NetSure™ DC power systems equipped with ACU+ controller. Application The Solar Sub Rack is intended for telecom sites in the access and transmission network, providing an alternative energy source (solar energy) to the existing grid connection or battery/diesel generator hybrid. Savings in electricity and diesel fuel costs can be achieved by operating on solar energy during the daylight hours. Main Sub Rack Extension Sub Rack EN604DRA-SolarRack / 1012 1 Solar Sub Rack Technical Specifications Main Sub Rack Input Voltage Range Max Static Input Voltage Configuration Interface From Solar Array Output Voltage Range Output Power Max Output Current Interface to -48 DC Power System Temperature Range, Operational Relative Humidity Safety Dimensions (H x W X D) Weight 58 to 150 VDC 165 VDC 1 solar converter (S48-3000) Terminal block, 2 x 16 mm2, rear connected -48 to 58 VDC 3 kW 61 A Terminal block, 2 x 16 mm2, rear connected -20 to +55 °C ≤ 95 % EN62109-1:2010 and EN50178:1997 44 x 440 x 355 mm (1.73 x 17.32 x 13.97 in.) < 8 kg (17.63 lb.) with solar converter installed Extension Sub Rack Input Voltage Range Max Static Input Voltage Configuration Interface From Solar Array Output Voltage Range Output Power Max Output Current Interface To -48 DC Power System Temperature Range, Operational Relative Humidity Safety Dimensions (H X W X D) Weight 58 to 150 VDC 165 VDC 2 solar converters (S48-3000) Terminal block, 4 x 16 mm2, rear connected -48 to 58 VDC 2 x 3 kW 2 x 61 A Terminal block, 4 x 16 mm2, rear connected -20 to +55 °C ≤ 95 % EN62109-1:2010 and EN50178:1997 44 x 440 x 355 mm (1.73 x 17.32 x 13.97 in.) < 11 kg (24.25 lb.) with two solar converters installed Solar Converter S48-3000 For information regarding the solar converter, refer to the separate data sheet. Ordering Information Description Solar sub rack Solar sub rack extension Accessories 19" mounting kit for 1 sub rack 19" mounting kit for 2 sub racks 19" mounting kit for 3 sub racks 23" mounting kit for 1 sub rack 23" mounting kit for 2 sub racks 23" mounting kit for 3 sub racks 3 kW MPPT solar converter (S48-3000) EmersonNetworkPower.com/EnergySystems (North America) EmersonNetworkPower.eu/EnergySystems (EMEA) © Emerson Network Power Energy Systems North America 2012. Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson® and Consider it Solved are service marks and trademarks of Emerson Electric Co. EnergyMaster™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure® and NetXtend™ are trademarks of Emerson Network Power Energy Systems North America. 2 EN604DRA-SolarRack / 1012