Master Flow EmberShield Color Data Sheet

advertisement
Master Flow® EmberShield®
Color Data Sheet
Updated: 11/15
MASTER FLOW
®
EMBERSHIELD
®
CLOSEABLE SOFFIT VENT 16.5" x 9" (419 mm x 229 mm)
• Intelligent Design… The vent openings go
from black to silver, identifying when the vents
are fully closed.
• E asy to Install… With just four screws (included).
They can be installed in new construction or retrofit
applications by removing existing soffit vents (up
to 16” x 8” [406 mm x 203 mm]).
Vent Opened
•S
imple to Operate… Vents slide open and closed
with anything long enough to reach them (extension
poles, broom handles, etc.).
•G
ood Ventilator… Provides 56 sq. in. (36,131 mm2)
of NFA for critical attic intake airflow when vent
is open.²
Vent Closed
Specifications
SOFFIT VENTS
CLOSEABLE
Helps prevent wildfire embers from
being drawn into the attic
gaf.com
•1
6.5” x 9” x 5/8”
(419 mm x 229 mm x 15.9 mm)
• P aintable finish
Extreme Weather & Wildfires
As extreme weather conditions around
the country persist and the threat of wildfires
continues to grow, more and more property
owners are becoming susceptible to the loss
of property due to wildfires.¹ Airborne embers
often pose one of the greatest threats to
homes and properties in the vicinity of
a wildfire because they can be carried by
the wind and cause new wildfires to erupt.
•5
6 sq. in. (36,131 mm2) of NFA
• Integral screen
Description
EmberShield® Closeable Soffit Vents are
manufactured with heavy-duty materials at
the GAF Burgaw, NC, plant using the latest
technology in manufacturing to provide a
product of the highest quality and performance.
Features & Benefits
•M
aximum Protection… During wildfire
conditions, homeowners or first responders
can close the EmberShield® Closeable Soffit
Vents, helping prevent dangerous embers
from entering the attic.
¹ GAF's limited product warranty does not cover damage caused by fire, including
wildfire embers. See Master Flow® Ventilation Products Limited Warranty for complete coverage and restrictions.
For technical information, contact GAF Master Flow®
products at 1-800-211-9612.
² Always have a balanced attic ventilation system. Balanced ventilation requires
an equal amount of intake ventilation and exhaust ventilation. GAF recommends
at minimum providing 1 square foot of net free ventilation for every 300 square
feet of attic floor space. In no case should the amount of exhaust ventilation
exceed the amount of intake ventilation. Always consult local building codes
for other ventilation requirements.
®