Page 1 of 2 Florida Building Code Online

advertisement
Florida Building Code Online
BCIS Home
Log In
User Registration
Page 1 of 2
Hot Topics
Submit Surcharge
Stats & Facts
Publications
FBC Staff
BCIS Site Map
Links
Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL5680-R15
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
GAF
Address/Phone/Email
1 Campus Drive
Parisppany, NJ 07054
(973) 872-4421
lindareith@trinityerd.com
Authorized Signature
Beth McSorley
lindareith@trinityerd.com
Technical Representative
Beth McSorley (current)
Address/Phone/Email
1 Campus Drive
Parsippany, NJ 07054
(973) 872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Modified Bitumen Roof System
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer

Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Robert J.M. Nieminen
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
01/06/2017
Validated By
John W. Knezevich, PE

Validation Checklist - Hardcopy Received
Certificate of Independence
FL5680_R15_COI_2015_01_COI_Nieminen.pdf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D6162
2000
ASTM D6163
2000
ASTM D6164
2005
ASTM D6222
2008
FM 4470
1992
FM 4474
2004
TAS 114
2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt45H1a2AP3I...
11/19/2015
Florida Building Code Online
Product Approval Method
Page 2 of 2
Method 1 Option D
Date Submitted
04/06/2015
Date Validated
04/08/2015
Date Pending FBC Approval
04/12/2015
Date Approved
06/23/2015
Summary of Products
FL #
Model, Number or Name
5680.1
GAF Modified Bitumen Roof Systems
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-465
Other: 1.) The DP noted herein pertains to one specific system. Refer to
the ER Appendix for all systems and max. design pressures. 2.) Refer to
ER Section 5 for Limits of Use.
Back
Description
SBS and APP Modified Bitumen Roof Systems
Installation Instructions
FL5680_R15_II_2015_04_FINAL_A1_ER_GAF_MB_FL5680-R15.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5680_R15_AE_2015_04_FINAL_ER_GAF_MB_FL5680-R15.pdf
Created by Independent Third Party: Yes
Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt45H1a2AP3I...
11/19/2015
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 Christian Street, Unit 13
Oxford, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
Evaluation Report 01506.11.05-R15
FL5680-R15
Date of Issuance: 11/07/2005
Revision 15: 04/06/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: GAF Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “TRINITY|ERD Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 76-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facimilie seal appearing was authorized by Robert Nieminen, P.E.
on 04/06/2015. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in
any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1.
SCOPE:
Product Category:
Roofing
Sub-Category:
Modified Bitumen Roof Systems
Compliance Statement: Modified Bitumen Roof Systems, as produced by GAF, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2.
3.
STANDARDS:
Section
Property
Standard
Year
1504.3.1
1515.1.1
1504.7
1507.11.2
1507.11.2
1507.11.2
1507.11.2
Wind
Wind
Impact
Physicals
Physicals
Physicals
Physicals
FM 4474
TAS 114
FM 4470
ASTM D6162
ASTM D6163
ASTM D6164
ASTM D6222
2004
2011
1992
2000
2000
2005
2008
Entity
Examination
Reference
Date
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
Florida TEC (TST7393)
Florida TEC (TST7393)
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114/FM4474
TAS 114/FM4474
TAS 114/FM4474
TAS 114/FM4474
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
TAS 114/FM4474
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
TAS 114
TAS 114
ACRC 06-041
ACRC 06-042
ACRC 06-043
ACRC 006-044
ACRC 06-048
ACRC 06-049
ACRC 06-050
ACRC 07-006
ACRC 07-018
ACRC 07-028
ACRC 07-030
ACRC 07-032
ACRC 07-033
ACRC 07-041
ACRC 07-044
ACRC 07-047
ACRC 07-081
ACRC 07-082
ACRC 08-024
ACRC 08-034
ACRC 08-044
ACRC 11-043
ACRC 11-046
ACRC 11-048
ACRC 11-049
ACRC 11-050
ACRC 11-051
ACRC 11-052
ACRC 11-053
ACRC 11-054
ACRC 12-015
ACRC 12-026
ACRC 12-034
ACRC 12-035
01880.09.03
01516.04.06
4482.10.97-1
G4280LAB.10.06-R1
G6850.08.08
G6850.08.08-1
G6850.10.08
G6850.11.08
G12210.06.09
G12210.01.10
G31360.03.10
G33470.01.11
G36780.07.11-R1
G40620.07.12-2
G43190.11.13-1
G40630.01.14-1
G40630.01.14-2A
G40630.01.14-2A-1
G40630.01.14-2B
G40630.01.14-2C
G43180.01.14-1
08-050187
08-050188
11/10/2006
11/14/2006
11/16/2006
11/16/2006
12/21/2006
12/22/2006
12/28/2006
01/17/2007
04/20/2007
05/08/2007
05/09/2007
05/10/2007
05/10/2007
08/31/2007
09/05/2007
09/07/2007
01/10/2008
01/11/2008
04/18/2008
05/19/2008
07/01/2008
08/08/2011
08/09/2011
08/10/2011
08/10/2011
08/11/2011
08/11/2011
08/12/2011
08/17/2011
08/17/2011
04/24/2012
05/10/2012
08/10/2012
08/13/2012
09/10/2003
04/20/2006
12/02/2006
12/06/2007
08/01/2008
08/29/2008
10/06/2008
11/05/2008
08/03/2009
01/08/2010
03/31/2010
01/13/2011
07/18/2011
07/17/2012
11/15/2013
01/06/2014
01/07/2014
01/07/2014
01/07/2014
01/07/2014
01/10/2014
04/28/2008
04/28/2008
REFERENCES:
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.11.04-R15
FL5680-R15
Revision 15: 04/06/2015
Page 2 of 6
Entity
Examination
Reference
Date
Florida TEC (TST7393)
Florida TEC (TST7393)
Florida TEC (TST7393)
Florida TEC (TST7393)
Florida TEC (TST7393)
Florida TEC (TST7393)
Florida TEC (TST7393)
Florida TEC (TST7393)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
08-070077
08-070084
08-050181R
08-050186
08-070126
08-070122
08-070127
08-080077
1B9A8.AM
3007500
3005640
3008178
3010215
3009788
3011140
3013614
3013788
3014547
3014692
3014960
3017250
3022139
3022508
3025023
797-02095-267
3023458
3028039
3024805
3032388
3032695
3032943
3032811
3033719
3035864
3032172
3035140
3036225
3034978
797-05447-267
797-05487-267
797-05550-267
797-05538-267
797-05594-267
797-05695-267
797-05683-267
797-05687-267
797-05748-267
3040738
3036960
797-06129-267
797-06177-267
797-06540-267
797-06800-267
797-07038-267
797-07073-267
3038128
3040738
3041535
3044688
797-07198-267
3044688 (Re-Issue)
3044541
3044862
3043900
3046280
3046388
3041769
3046403
3046054
3046081
797-08216-267
3048122
3047104
797-08263-267
797-08264-267
3047237
797-08670-267
797-08873-267
3048871
3048066
797-09016-267
3048496
3049601
797-09984-267
07/25/2008
07/25/2008
04/01/2009
10/14/2008
10/14/2008
10/14/2008
10/14/2008
11/17/2008
09/04/1997
06/15/2000
11/09/2000
12/27/2000
03/01/2001
03/28/2001
08/14/2001
05/06/2002
01/10/2003
05/22/2003
08/05/2003
03/05/2004
04/05/2004
05/26/2005
07/20/2005
12/14/2005
04/26/2006
07/18/2006
09/11/2006
11/20/2006
10/30/2008
10/30/2008
11/06/2008
12/11/2008
01/16/2009
06/03/2009
06/12/2009
08/10/2009
08/10/2009
09/17/2009
04/13/2010
05/12/2010
05/25/2010
05/25/2010
06/01/2010
07/15/2010
07/21/2010
07/21/2010
08/10/2010
11/16/2010
11/30/2010
01/13/2011
03/16/2011
06/21/2011
09/29/2011
01/10/2012
01/19/2012
07/26/2010
11/16/2010
06/08/2011
03/01/2012
03/01/2012
03/16/2012
04/04/2012
05/11/2012
08/16/2012
08/22/2012
09/24/2012
09/27/2012
09/28/2012
12/21/2012
02/13/2013
04/11/2013
04/29/2013
05/10/2013
05/23/2013
05/23/2013
07/15/2013
09/16/2013
11/26/2013
12/11/2013
12/13/2013
12/17/2013
12/19/2013
01/29/2014
10/28/2014
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.11.04-R15
FL5680-R15
Revision 15: 04/06/2015
Page 3 of 6
4.
Entity
Examination
Reference
Date
FM Approvals (TST1867)
FM Approvals (TST1867)
IRT (TST7408)
IRT (TST7408)
IRT (TST7408)
IRT (TST7408)
IRT (TST7408)
IRT (TST7408)
IRT (TST7408)
IRT (TST7408)
Miami-Dade (CER1592)
MTI (TST2508)
MTI (TST2508)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
UL, LLC (QUA9625)
FM 4470/4474
FM 4470/4474
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
Various
Physical Properties
Physical Properties
Physical Properties
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
Quality Assurance
797-09987-267
797-10017-267
00001
00002
01-039
02-005
02-014
03-003
03-004
04-008
Current NOAs
AX04C9A
RX30C9C
GAF-027-02-01
GAF-434-02-01
GAF-434-02-03
GAF-434-02-04
GAF-436-02-02
GAF-436-02-03
GAF-436-02-04
GAF-436-02-05
GAF-436-02-08
GAF-436-02-09
GAF-549-02-01
GAF-549-02-02
GAF-559-02-01
GAF-559-02-04
GAF-559-02-05
GAF-559-02-06
GAF-559-02-07
GAF-559-02-08
GAF-559-02-09
GAF-559-02-11
GAF-559-02-12
GAF-559-02-13
GAF-559-02-14
GAF-559-02-15
GAF-559-02-16
GAF-559-02-17
GAF-559-02-18
Inspection Report, R1306
10/28/2014
11/06/2014
03/30/2000
03/30/2000
01/24/2002
01/24/2002
03/26/2002
04/21/2003
04/21/2003
01/26/2004
Current
06/05/2009
07/09/2009
03/26/2002
09/16/2013
09/16/2013
09/16/2013
03/06/2014
03/06/2014
03/06/2014
03/06/2014
03/06/2014
03/06/2014
08/08/2014
08/08/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
10/16/2014
01/06/2015
PRODUCT DESCRIPTION:
This Evaluation Report covers GAF Modified Bitumen Roof Systems installed in accordance with GAF published installation
instructions and the Limitations / Conditions of Use herein. The following products make up the subject systems.
TABLE 1: ROLL-GOODS FOR GAF MODIFIED BITUMEN ROOF SYSTEMS
Type
Base Sheet
Product
Type
Grade
GAFGLAS® #75 Base Sheet
ASTM D4601
II
N/A
Tri-Ply® #75 Base Sheet
ASTM D4601
II
N/A
GAFGLAS® #80 Ultima™ Base Sheet
ASTM D4601
II
N/A
StormSafe™ Anchor Sheet
Proprietary
N/A
N/A
ASTM D4897
II
N/A
ASTM D4897
II
N/A
N/A
N/A
GAFGLAS® Stratavent® Nailable Venting Base Sheet (formerly
GAFGLAS® Stratavent® Eliminator™ Nailable Venting Base Sheet)
GAFGLAS® Stratavent® Perforated Venting Base Sheet (formerly
GAFGLAS® Stratavent® Eliminator™ Perforated Venting Base Sheet)
Liberty™ SBS Mechanically Attached Base Sheet (formerly Liberty™ MA
Mechanically-Attached Base Sheet)
Ply Sheet
Specification
Reference
Proprietary
GAFGLAS® Ply 4
ASTM D2178
IV
N/A
Tri-Ply® Ply 4
ASTM D2178
IV
N/A
GAFGLAS® FlexPly™ 6
ASTM D2178
VI
N/A
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.11.04-R15
FL5680-R15
Revision 15: 04/06/2015
Page 4 of 6
TABLE 1 (CONTINUED): ROLL-GOODS FOR GAF MODIFIED BITUMEN ROOF SYSTEMS
Type
Smooth Surfaced
Membranes:
Type
Grade
Liberty™ SBS Self-Adhering Base/Ply Sheet
ASTM D1970
N/A
N/A
UnderRoof™ 2 Polyester-Surfaced Leak Barrier
ASTM D1970
N/A
N/A
UnderRoof™ HT High Temperature Leak Barrier
ASTM D1970
N/A
N/A
WeatherWatch® XT Mat Surfaced Leak Barrier
ASTM D1970
N/A
N/A
Ruberoid® 20 Smooth (formerly Ruberoid® 20)
ASTM D6163
I
S
Ruberoid® HW 25 Smooth (formerly Ruberoid® SBS Heat-Weld 25)
ASTM D6163
I
S
Ruberoid® HW Smooth (formerly Ruberoid® SBS Heat-Weld Smooth)
ASTM D6164
I
S
Ruberoid® Mop Smooth
ASTM D6164
I
S
Ruberoid® Mop Smooth 1.5
ASTM D6164
I
S
Ruberoid® Mop Plus Smooth
ASTM D6164
II
S
Ruberoid® Torch Smooth
ASTM D6222
I
S
Tri-Ply® APP Smooth (formerly Tri-Ply® TP-4)
ASTM D6222
I
S
Ruberoid® 30 Granule (formerly Ruberoid® 30)
ASTM D6163
I
G
Ruberoid® 30 Granule FR (formerly Ruberoid® 30 FR)
ASTM D6163
I
G
ASTM D6163
I
G
Liberty™ SBS Self-Adhering Cap Sheet
ASTM D6164
I
G
Ruberoid® Mop Granule FR (formerly Ruberoid® Mop 170 FR)
ASTM D6164
I
G
Ruberoid® Mop Granule
ASTM D6164
I
G
Intec Flex PRF
ASTM D6164
I
G
Tri-Ply® SBS Granule (formerly Tri-Ply® SBS Modified Bitumen Membrane)
ASTM D6164
I
G
Ruberoid® HW Granule (formerly Ruberoid® SBS Heat-Weld Granule)
ASTM D6164
I
G
Ruberoid® HW Granule FR (formerly Ruberoid® SBS Heat-Weld 170 FR)
ASTM D6164
I
G
Ruberoid® Mop Plus Granule FR (formerly Ruberoid® Mop FR)
ASTM D6164
II
G
Ruberoid® Mop Plus Granule (formerly Ruberoid® Mop Plus)
ASTM D6164
II
G
ASTM D6164
II
G
Ruberoid® HW Plus Granule (formerly Ruberoid® SBS Heat-Weld Plus)
ASTM D6164
II
G
Ruberoid® HW Plus Granule FR (formerly Ruberoid® SBS Heat-Weld Plus FR)
ASTM D6164
II
G
ASTM D6164
II
G
Ruberoid® Torch Granule
ASTM D6222
I
G
Tri-Ply® APP Granule (formerly Tri-Ply® TP-4G)
ASTM D6222
I
G
Ruberoid® Torch Plus Granule FR (formerly Ruberoid® Torch FR)
ASTM D6222
II
G
Ruberoid® EnergyCap™ Torch Granule FR
ASTM D6222
I
G
ASTM D6222
II
G
Ruberoid® EnergyCap™ 30 Granule FR (formerly Ruberoid® EnergyCap™ 30
FR SBS Membrane)
Granule Surfaced
Membranes:
Ruberoid® EnergyCap™ Mop Plus Granule FR (formerly Ruberoid®
EnergyCap™ Mop FR)
Ruberoid® EnergyCap™ HW Plus Granule FR (formerly Ruberoid®
EnergyCap™ SBS Heat-Weld Plus FR)
Ruberoid® EnergyCap™ Torch Plus Granule FR (formerly Ruberoid®
EnergyCap™ Torch Plus FR)
5.
Specification
Product
Reference
LIMITATIONS:
5.1
This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design
guidance unless retained specifically for that purpose.
5.2
This Evaluation Report is not for use in HVHZ jurisdictions.
5.3
Refer to a current Roofing Materials Directory for fire ratings of this product.
5.4
For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC
2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5
The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be
in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be
documented through proper codified and/or FBC Approval documentation.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.11.04-R15
FL5680-R15
Revision 15: 04/06/2015
Page 5 of 6
6.
7.
5.6
For recover installations, the existing roof shall be examined in accordance with FBC 1510.
5.7
For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16.
Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated
pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry
the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
5.8
For fully-adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design
pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems
5.9
For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck
for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
5.10
For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing
deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface
conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS
1-52 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly.
5.11
For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be
capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field
uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124.
5.12
Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter
16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be
determined from FBC Figure 1609.
5.13
All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3.
INSTALLATION:
6.1
GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF’s published installation instructions,
subject to the Limitations / Conditions of Use noted herein.
6.2
System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design
Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind loads.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8.
MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9.
QUALITY ASSURANCE ENTITY:
UL, LLC – QUA9625; (847) 664-3281
- THE 76-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.11.04-R15
FL5680-R15
Revision 15: 04/06/2015
Page 6 of 6
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
1A
Wood
New, Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
1B-1
Wood
New, Reroof (Tear-Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-8
1B-2
Wood
New, Reroof (Tear-Off), Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
9-11
1C
Wood
New, Reroof (Tear-Off), Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
12
1D
Wood
New, Reroof (Tear-Off), Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12
1E
Wood
New, Reroof (Tear-Off), Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
1F-1
Wood
New, Reroof (Tear-Off)
E
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
13-14
1F-2
Wood
New, Reroof (Tear-Off), Recover
E
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
15
2A-1
Steel or Conc.
New, Reroof (Tear-Off), Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
2A-2
Steel or Conc.
New, Reroof (Tear-Off), Recover
B-2
Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover
2B-1A
Steel or Conc.
New, Reroof (Tear-Off), Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
2B-1B
Steel or Conc.
New, Reroof (Tear-Off), Recover
C-1A
Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover
2B-2
Steel or Conc.
New, Reroof (Tear-Off), Recover
C-2
Bonded and Mech. Attached Insulation, Bonded Roof Cover
2C
Steel or Conc.
New, Reroof (Tear-Off), Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
34-37
3A-1
Concrete
New, Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only)
38-40
3A-2
Concrete
New, Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers)
41-49
3A-3
Concrete
New, Reroof (Tear-Off)
A-1a
Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover
50-52
3B
Concrete
New, Reroof (Tear-Off)
F
Non-Insulated, Bonded Roof Cover
4A
LWIC
New, Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
4B
LWIC
New or Reroof (Tear-Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4C
LWIC
New, Reroof (Tear-Off)
E
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
4D
LWIC
New, Reroof (Tear-Off)
F
Non-Insulated, Bonded Roof Cover
59
5A
CWF
New, Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
60
5B
CWF
New, Reroof (Tear-Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
61
5C
CWF
New, Reroof (Tear-Off)
E
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
62
6A
Gypsum
Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
63
6B
Gypsum
Reroof (Tear-Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
63
6C
Gypsum
Reroof (Tear-Off)
C
Mech. Attached Insulation, Bonded Roof Cover
6D
Gypsum
Reroof (Tear-Off)
E
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
64-65
7A-1
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only)
66-69
7A-2
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers)
70-76
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Page
4
13
16-22
23
24-32
33
33
53
54-55
56
57-59
64
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 1 of 76
The following notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2.
Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
 Wood:
Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation
only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank
embedment.
 Steel:
Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac
Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener - Insulation.
Minimum 0.75-inch steel penetration and engage the top flute of the steel deck.
 Concrete:
Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only) or
Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate. Minimum 1-inch embedment into pilot hole in accordance with the fastener manufacturer’s published
installation instructions.
3.
Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. VersaShield® Solo™ Fire-Resistant Slip Sheet may be
used as a non-load-bearing, fire-barrier slip-sheet component within any system outlined herein.
4.
Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
5.
Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
 Hot asphalt (HA):
Full coverage at 25-30 lbs/square
 OMG OlyBond 500 (OB500):
Continuous 0.75-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used
where OlyBond 500 is referenced.
 GAF LRF Adhesive M (LRF-M):
Continuous 1-inch wide ribbons, 12-inch o.c
 ADCO Millennium One-Step Foamable Adhesive (M-OSFA):
Continuous 1-inch wide ribbons, 12-inch o.c.
 GAF 2-Part Roofing Adhesive (GAF 2-Part):
Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Note: 3M CR-20 may be used where GAF 2-Part is referenced.
 Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing.
 Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6.
Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table.
 Hot asphalt (HA):
MDP
-240.0 psf (Min. 0.5-inch thick)
 OMG OlyBond 500 (OB500):
MDP
-315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN)
 OMG OlyBond 500 (OB500):
MDP
-485.0 psf (Min. 0.5-inch thick EnergyGuard RA)
 GAF 2-Part Roofing Adhesive (GAF 2-Part):
MDP
-117.5 psf (Min. 1.0-inch thick)
7.
Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
8.
For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
9.
For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 2 of 76
11. For existing substrates in a bonded recover installation, the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or ANSI/SPRI IA-1.
12. For Recover Applications using System Type D, the insulation is optional. Alternatively, min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra,
Structodek High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board may be used as a separator board prior to base sheet installation. The existing roof system shall be suitable for a recover application. The
separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover in Recover applications.
13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
Reference
Layer
Material
Base:
BP-AA
(Base/ Ply sheets, Asphalt-Applied)
Ply:
Application
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet
Hot asphalt at 25 lbs/square.
One or more plies GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6
BP-CA
(Base/ Ply sheets, Cold-Applied)
Base:
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet
Matrix™ 102 SBS Membrane Adhesive
(formerly known as TOPCOAT MATRIX 102
SBS Membrane Adhesive) at 1.5 gal/sq.
B-LL
(Base sheet, Loose-Laid)
Base:
GAFGLAS Stratavent Perforated Venting Base Sheet
Loose laid
Base or Ply:
SBS-AA
(SBS, Asphalt-Applied)
SBS-CA
(SBS, Cold-Applied, Matrix™ 102 SBS
Membrane Adhesive)
Cap:
Base or Ply:
Cap:
Base:
SBS-CA-1
(SBS, Cold-Applied, Matrix™ 101
Premium SBS Membrane Adhesive)
SBS-TA
(SBS, Torch-Applied)
APP-TA
(APP, Torch-Applied)
SBS-SA (self-adhering)
Cap:
Base or Ply:
Cap:
Base or Ply:
Cap:
Base or Ply:
Cap
One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth
Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid Mop
Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule, Intec
Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus Granule FR
Hot asphalt at 25 lbs/square.
Ruberoid 20 Smooth
Matrix™ 102 SBS Membrane Adhesive
(formerly known as TOPCOAT MATRIX 102
SBS Membrane Adhesive) at 1.5 gal/sq.
Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule FR,
Ruberoid EnergyCap Mop Plus Granule FR
Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5
Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop
Plus Granule FR
Matrix™ 101 Premium SBS Membrane
Adhesive (formerly known as TOPCOAT
MATRIX Majorbond Modified Bitumen
Membrane Adhesive) at 1.5 – 2.0
gal/square
One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth
Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid
EnergyCap HW Plus Granule FR
One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth
Torch applied
Ruberoid Torch Granule, Tri-Ply APP Granule, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch Granule FR,
Ruberoid EnergyCap Torch Plus Granule FR
Liberty SBS Self-Adhering Base/Ply Sheet
Self-adhered
Liberty SBS Self-Adhering Cap Sheet
14. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 3 of 76
TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Attach
Type
GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-TA or
APP-TA
-52.5
GAF 2-Part
BP-AA, SBS-AA, SBSTA or APP-TA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-TA or
APP-TA
-52.5
GAF 2-Part
WeatherWatch XT
Mat Surfaced Leak
Barrier
(Optional) SBS-TA, APPTA
SBS-TA, APP-TA
-52.5
W-1.
Min. 19/32-inch
plywood or OSB at max.
24-inch span
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
W-2.
Min. 19/32-inch
plywood or OSB at max.
24-inch span
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
GAF 2-Part
Min. 0.25-inch Dens Deck,
Dens Deck Prime or
SECUROCK Gypsum-Fiber
Roof Board
W-3.
Min. 19/32-inch
plywood or OSB at max.
24-inch span
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
GAF 2-Part
Min. 0.25-inch Dens Deck,
Dens Deck Prime or
SECUROCK Gypsum-Fiber
Roof Board
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Roof Cover
Attach
Base
Ply
Cap
MDP (psf)
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 4 of 76
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Anchor Sheet
Deck
(See Note 1)
Type
Base Insulation
Fasteners
Attach
Type
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
Top Insulation
Attach
Type
Roof Cover
Attach
MDP
(psf)
Base
Ply
Cap
HA
BP-AA, SBSAA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
HA
BP-AA, SBSAA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
HA
BP-AA, SBSAA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
HA
BP-AA, SBSAA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
CONVENTIONAL SYSTEMS:
W-4.
W-5.
W-6.
W-7.
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
8-inch o.c. at
min. 4-inch laps
and 8-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
8-inch o.c. at
min. 4-inch laps
and 8-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
HA
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 5 of 76
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
W-8.
W-9.
W-10.
W-11.
Anchor Sheet
Deck
(See Note 1)
Type
Fasteners
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
Min. 19/32inch
plywood at
max. 24inch span
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Base Insulation
Attach
Type
6-inch o.c. at the
4-inch lap and 6inch o.c. in two
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
6-inch o.c. at the
4-inch lap and 6inch o.c. in two
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
8-inch o.c. at the
4-inch lap and 8inch o.c. in two
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
8-inch o.c. at the
4-inch lap and 8inch o.c. in two
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
Top Insulation
Attach
Type
HA
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
Roof Cover
Attach
MDP
(psf)
Base
Ply
Cap
HA
BP-AA, SBSAA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
HA
BP-AA, SBSAA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
HA
BP-AA, SBSAA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
HA
BP-AA, SBSAA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 6 of 76
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
W-12.
W-13.
Anchor Sheet
Deck
(See Note 1)
Base Insulation
Type
Fasteners
Attach
Type
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 9-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 9-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 2-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 2-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Top Insulation
Attach
Type
Roof Cover
Attach
MDP
(psf)
Base
Ply
Cap
HA
BP-AA, SBSAA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
HA
BP-AA, SBSAA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
SBS-SA,
SBS-TA
or APPTA
-45.0
SBS-TA,
APP-TA
-45.0
HA
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
SBS-SA
(Optional)
SBS-SA,
SBS-TA or
APP-TA
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso or min. 1.5inch EnergyGuard RA
or EnergyGuard RN
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
Weather
Watch XT
Mat Surfaced
Leak Barrier
(Optional)
SBS-TA,
APP-TA
SELF-ADHERING SYSTEMS:
W-14.
W-15.
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
VENTING SYSTEMS:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 7 of 76
TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Anchor Sheet
Deck
Base Insulation
Top Insulation
Roof Cover
MDP
(psf)
(See Note 1)
Type
Fasteners
Attach
Type
W-16.
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
8-inch o.c. at
min. 4-inch laps
and 8-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base
insulation
HA
B-LL
(Optional)
BP-AA,
SBS-AA
SBS-AA
-45.0
W-17.
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base
insulation
HA
B-LL
(Optional)
BP-AA,
SBS-AA
SBS-AA
-45.0
W-18.
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
6-inch o.c. at
min. 4-inch laps
and 6-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base
insulation
HA
B-LL
(Optional)
BP-AA,
SBS-AA
SBS-AA
-52.5
W-19.
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 15/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
8-inch o.c. at the
4-inch lap and 8inch o.c. in two
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base
insulation
HA
B-LL
(Optional)
BP-AA,
SBS-AA
SBS-AA
-52.5
W-20.
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 15/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 9-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation,
EnergyGuard Ultra
Polyiso Insulation or
EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base
insulation
HA
B-LL
(Optional)
BP-AA,
SBS-AA
SBS-AA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Attach
Type
Attach
Base
Ply
Cap
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 8 of 76
TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note
1)
Anchor Sheet
Type
Fasteners
Base Insulation
Attach
Type
See Note
2
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2 (#14
ONLY)
16-inch o.c. at the
min. 4-inch lap
and 16-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2 (#14
ONLY)
16-inch o.c. at the
min. 4-inch lap
and 16-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
Top Insulation
Attach
Type
Roof Cover
Attach
Base
MDP
(psf)
Ply
Cap
SBS-AA,
SBS-TA,
APP-TA
-45.0
CONVENTIONAL SYSTEMS:
W-21.
W-22.
W-23.
W-24.
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
HA
Min. 0.5-inch
Structodek High Density
Fiberboard Roof
Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
Min. 0.5-inch
Structodek High Density
Fiberboard Roof
Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
HA
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 9 of 76
TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
W-25.
W-26.
W-27.
W-28.
Deck
(See Note
1)
Anchor Sheet
Type
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 19/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Fasteners
Base Insulation
Attach
Type
See Note
2 (#14
ONLY)
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2 (#14
ONLY)
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2
12-inch o.c. at the
min. 2-inch lap
and 12-inch o.c. in
three, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2
12-inch o.c. at the
min. 2-inch lap
and 12-inch o.c. in
three, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
Top Insulation
Attach
Type
HA
Min. 0.5-inch
Structodek High Density
Fiberboard Roof
Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
Min. 0.5-inch
Structodek High Density
Fiberboard Roof
Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
Roof Cover
Attach
Base
MDP
(psf)
Ply
Cap
SBS-AA,
SBS-TA,
APP-TA
-60.0
HA
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
HA
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 10 of 76
TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note
1)
Anchor Sheet
Type
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
W-31.
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
W-32.
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
W-33.
Min. 15/32inch
plywood at
max. 24inch span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
W-29.
W-30.
Fasteners
Base Insulation
Attach
Type
Attach
Type
HA
Min. 0.5-inch
Structodek High Density
Fiberboard Roof
Insulation or
EnergyGuard Perlite
Recover Board or Min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK GypsumFiber Roof Board
HA
(Optional) Additional
layer(s) base insulation
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base insulation
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso
HA
(Optional) Additional
layer(s) base insulation
8-inch o.c. at the
4-inch lap and 8inch o.c. in three
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2 (#14
ONLY)
8-inch o.c. at the
4-inch lap and 8inch o.c. in three
staggered center
rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso or min. 1.5-inch
EnergyGuard RA or
EnergyGuard RN
See Note
2 (#14
ONLY)
16-inch o.c. at the
min. 4-inch lap
and 16-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra Polyiso Insulation
or EnergyGuard RH
Polyiso
See Note
2 (#14
ONLY)
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
See Note
2 (#14
ONLY)
8-inch o.c. at the
4-inch lap and 8inch o.c. in three
staggered center
rows
See Note
2 (#14
ONLY)
Top Insulation
Roof Cover
Attach
Base
MDP
(psf)
Ply
Cap
SBS-AA,
SBS-TA,
APP-TA
-75.0*
HA
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-82.5
B-LL
One or
more BPAA, SBSAA
SBS-AA,
SBS-TA,
APP-TA
-52.5
HA
B-LL
One or
more BPAA, SBSAA
SBS-AA,
SBS-TA,
APP-TA
-60.0
HA
B-LL
One or
more BPAA, SBSAA
SBS-AA,
SBS-TA,
APP-TA
-82.5*
VENTING SYSTEMS:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
HA
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 11 of 76
TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
Roof Cover
Deck
(See Note 1)
Type
Fasteners
Attach
W-34.
Min. 19/32-inch plywood
at max. 24-inch span
Min. 1-inch
EnergyGuard RN
Drill-Tec #12 Fastener with
Drill-Tec AccuTrac Flat
Plate or AccuTrac
Recessed Plate
1 per 1.78
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500
SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-52.5
W-35.
Min. 19/32-inch plywood
at max. 24-inch span
Min. 1-inch
EnergyGuard RN
Drill-Tec #12 Fastener with
Drill-Tec AccuTrac Flat
Plate or AccuTrac
Recessed Plate
1 per 1.78
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500
WeatherWatch XT
Mat Surfaced Leak
Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-52.5
System No.
Type
Attach
Base
Ply
Cap
MDP
(psf)
TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Roof Cover
Fasteners
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
W-36.
Min. 19/32-inch plywood at
max. 24-inch span
Min. 0.75-inch, one or more
layers, any combination, loose
laid
Min. 1.5-inch EnergyGuard Composite or
EnergyGuard RA Composite
See Note 2
1 per 3 ft2
BP-AA, SBSAA
(Optional) BPAA, SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-37.
Min. 19/32-inch plywood at
max. 24-inch span
Min. 0.75-inch, one or more
layers, any combination, loose
laid
Min. 1-inch Structodek High Density
Fiberboard Roof Insulation or min. 0.75inch EnergyGuard Perlite Roof Insulation
(homogeneous)
See Note 2
1 per 2 ft2
BP-AA, SBSAA
(Optional) BPAA, SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-38.
Min. 19/32-inch plywood at
max. 24-inch span
(Optional) One or more layers,
any combination, loose laid
Min. 0.25-inch SECUROCK Gypsum Fiber
Roof Board
See Note 2 (#14
only)
1 per 1.78
ft2
BP-AA, SBSAA, SBS-TA,
APP-TA
(Optional) BPAA, SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
(Optional) One or more layers,
any combination, loose laid
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
See Note 2 (HD
Fasteners only)
1 per 2 ft2
SBS-SA
(Optional) SBSSA
SBS-SA
-45.0
SELF-ADHERING SYSTEMS:
W-39.
Min. 15/32-inch plywood at
max. 24-inch span
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 12 of 76
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Insulation Layer(s)
Type
Base or Anchor Sheet
Attach
Base
Fasteners
Roof Cover
Cap
MDP
(psf)
Attach
Ply
See Note 2
12-inch o.c. at min. 2-inch laps and 12inch o.c. in two, equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-45.0
See Note 2
12-inch o.c. at min. 2-inch laps and 12inch o.c. in three, equally spaced,
staggered center rows
BP-AA, SBSAA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-60.0
See Note 2
8-inch o.c. at min. 2-inch laps and 8-inch
o.c. in three, equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-75.0
CONVENTIONAL SYSTEMS:
W-40.
Min. 19/32-inch
plywood at max.
24-inch span
Min. 1-inch, one or
more layers, any
combination
Prelim
attach
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, #80 Ultima Base Sheet,
Stratavent Nailable Venting Base Sheet,
Ruberoid 20 Smooth
W-41.
Min. 19/32-inch
plywood at max.
24-inch span
Min. 1-inch, one or
more layers, any
combination
Prelim
attach
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, #80 Ultima Base Sheet,
Stratavent Nailable Venting Base Sheet,
Ruberoid 20 Smooth
W-42.
Min. 19/32-inch
plywood at max.
24-inch span
Min. 1-inch, one or
more layers, any
combination
Prelim
attach
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, #80 Ultima Base Sheet,
Stratavent Nailable Venting Base Sheet,
Ruberoid 20 Smooth
TABLE 1F-1: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER
System
No.
Base Sheet
Deck (See Note 1)
Type
Roof Cover
Faster
Attachment
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
W-43.
Min. 15/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
8-inch o.c. at min. 4-inch laps and 8-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-45.0
W-44.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth,
Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia. tin
caps with 12 ga. annular
ring shank nails
9-inch o.c. at min. 4-inch laps and 9-inch
o.c. at two, equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-45.0
W-45.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
9-inch o.c. at min. 4-inch laps and 12-inch
o.c. in two, equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-45.0
W-46.
Min. 15/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
6-inch o.c. at min. 4-inch laps and 6-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 13 of 76
TABLE 1F-1: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER
System
No.
Base Sheet
Deck (See Note 1)
Type
Roof Cover
Faster
Attachment
Ply
Cap
MDP
(psf)
W-47.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
9-inch o.c. at min. 4-inch laps and 9-inch
o.c. in two, equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-52.5
W-48.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth,
Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
9-inch o.c. at min. 4-inch laps and 9-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
APP-TA
APP-TA
-60.0
W-49.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth,
Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia. tin
caps with 12 ga. annular
ring shank nails
8-inch o.c. at min. 4-inch laps and 8-inch
o.c. at three, equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-75.0
W-50.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth,
Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
7-inch o.c. at min. 4-inch laps and 7-inch
o.c. in three, equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-82.5
SELF-ADHERING SYSTEMS:
W-51.
Min. 19/32-inch
plywood at max.
24-inch span
Liberty SBS Mechanically Attached Base Sheet
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
9-inch o.c. at min. 4-inch laps and 9-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
SBS-SA
SBS-SA,
SBS-TA or
APP-TA
-37.5
W-52.
Min. 15/32-inch
plywood at max.
24-inch span
Liberty SBS Mechanically Attached Base Sheet
32 ga., 1-5/8-inch dia. tin
caps with 11 ga. annular
ring shank nails
8-inch o.c. at min. 3-inch laps and 8-inch
o.c. in three, equally spaced, staggered
center rows
(Optional)
SBS-SA
SBS-SA,
SBS-TA or
APP-TA
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 14 of 76
TABLE 1F-2: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER
System
No.
Base Sheet
Deck (See Note 1)
Type
Roof Cover
Faster
Attachment
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
W-53.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
See Note 2
12-inch o.c. at 2-inch laps and 12-inch
o.c. in two, equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA, SBS-TA,
SBS-CA, APP-TA
-45.0
W-54.
Min. 15/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
See Note 2 (#14
ONLY)
16-inch o.c. at 4-inch laps and 16-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-52.5
W-55.
Min. 15/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
See Note 2 (#14
ONLY)
12-inch o.c. at 4-inch laps and 12-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-60.0
W-56.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
See Note 2
12-inch o.c. at 2-inch laps and 12-inch
o.c. in three, equally spaced,
staggered center rows
BP-AA, SBSAA
SBS-AA, SBS-TA,
SBS-CA, APP-TA
-60.0
W-57.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #80 Ultima Base Sheet, Ruberoid 20 Smooth, Ruberoid
Mop Smooth, Ruberoid Mop Smooth 1.5
See Note 2
9-inch o.c. at 4-inch laps and 9-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
SBS-TA
SBS-TA (polyester
only)
-60.0
W-58.
Min. 15/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
See Note 2 (#14
ONLY)
8-inch o.c. at 4-inch laps and 8-inch
o.c. in three, equally spaced,
staggered center rows
(Optional)
BP-AA, SBSAA
SBS-AA
-97.5
W-59.
Min. 19/32-inch
plywood at max.
24-inch span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base
Sheet, Ruberoid 20 Smooth
See Note 2
8-inch o.c. at 2-inch laps and 8-inch
o.c. in three, equally spaced,
staggered center rows
BP-AA, SBSAA
SBS-AA, SBS-TA,
SBS-CA, APP-TA
-105.0
W-60.
Min. 19/32-inch
plywood at max.
24-inch span
StormSafe Anchor Sheet
See Note 2 (DrillTec AccuTrac Flat
Plate only)
9-inch o.c. at 4-inch laps and 9-inch
o.c. in three, equally spaced,
staggered center rows
(Optional)
SBS-SA
Note: Seams sealed
with TOPCOAT SB900
or Flexseal
W-61.
Min. 15/32-inch
plywood at max.
24-inch span
Liberty SBS Mechanically Attached Base Sheet
See Note 2 (HD
Fasteners only)
8-inch o.c. at 3-inch laps and 8-inch
o.c. in two, equally spaced, staggered
center rows
(Optional)
SBS-SA
SBS-SA, SBS-TA or
APP-TA
SELF-ADHERING SYSTEMS:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
SBS-SA
-60.0
-60.0
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 15 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
SC-1
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per 4
ft2
Min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous) or min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-37.5*
SC-2
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 0.625-inch Dens
Deck Prime
See
Note 2
1 per 4
ft2
Min. 1.5-inch EneryGuard followed by min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
HA
APP-TA
(Optional) APPTA
APP-TA
-45.0*
SC-3
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 0.5-inch Dens Deck
Prime
See
Note 2
1 per
2.67 ft2
Min. 1.5-inch EneryGuard followed by min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
HA
APP-TA
(Optional) APPTA
APP-TA
-45.0*
SC-4
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per
2.67 ft2
Min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous) or min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-5
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per 4
ft2
Min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous) or min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-6
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per 4
ft2
Min. 0.5-inch EnergyGuard Perlite Recover Board or
min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum Fiber Roof Board
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-7
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 0.5-inch EnergyGuard Perlite Recover Board or
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous) or Structodek High Density
Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-8
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Min. 0.5-inch EnergyGuard Perlite Recover Board or
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous) or Structodek High Density
Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-9
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN followed by min. 0.75-inch
EnergyGuard Perlite Roof Insulation
(homogeneous)
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 16 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
SC-10
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2.2-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 0.5-inch Structodek High Density Fiberboard
Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-11
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per
1.45 ft2
Min. 1.0-inch EnergyGuard Perlite Roof Insulation
(homogeneous)
HA
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA or
SBS-TA
-60.0
HA
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA
-60.0
SC-12
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
RH, EnergyGuard RN
See
Note 2
1 per
1.33 ft2
Optional additional layers base insulation followed
by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
SC-13
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per
1.45 ft2
Min. 0.5-inch Structodek High Density Fiberboard
Roof Insulation
HA
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA or
SBS-TA
-67.5
SC-14
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Optional additional layers of base insulation; Min.
0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA, GAF
2-Part,
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
SC-15
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Optional additional layers of base insulation; Min.
0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA, GAF
2-Part,
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
SC-16
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN or
EnergyGuard Ultra
See
Note 2
1 per 2
ft2
Min. 0.5-inch Structodek High Density Fiberboard
Roof Insulation
HA, GAF
2-Part or
OB500
BP-AA, SBS-AA
None
SBS-CA
-45.0*
SC-17
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board
HA, GAF
2-Part,
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 17 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
SC-18
Deck
(See Note 1)
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Base Insulation Layer
Top Insulation Layer
Type
Roof Cover
Type
Fasten
Attach
Attach
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per
1.6 ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
HA,
OB500
or GAF
2-Part
Min. 1.5-EnergyGuard RH
See
Note 2
1 per 2
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
1 per
2.9 ft2
Base
MDP
(psf)
Ply
Cap
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
OB500,
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-37.5*
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500,
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-37.5*
SELF-ADHERING SYSTEMS:
SC-19
Min. 22 ga., Type B,
Grade 33 steel or
structural concrete
SC-20
Min. 22 ga., Type B,
Grade 33 steel or
structural concrete
Min. 2-EnergyGuard RH
See
Note 2
SC-21
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per 2
ft2
Additional layer(s), min. 0.5-inch thick base
insulation
OB500,
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-22
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per
2.9 ft2
Additional layer(s), min. 0.5-inch thick base
insulation
OB500,
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-23
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per 4
ft2
Additional layer(s), min. 1.5-inch thick base
insulation
OB500,
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-24
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Optional additional layers of base insulation; Min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-25
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch thick base
insulation; Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500,
LRF-M,
M-OSFA
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 18 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
SC-26
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per 2
ft2
Optional additional layers, min. 1-nich thick base
insulation; Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
LRF-M,
M-OSFA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-27
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per
2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation; Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500,
LRF-M,
M-OSFA
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-28
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per
2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation; Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
LRF-M,
M-OSFA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-29
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-SA
(Optional) SBSSA
SBS-SA
-45.0*
SC-30
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Optional additional layers of base insulation; Min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-31
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation; Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500,
LRF-M,
M-OSFA
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-32
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
See
Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation; Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
LRF-M,
M-OSFA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-33
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-34
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per
1.6 ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-35
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
HA, GAF
2-Part
SBS-SA
(Optional) SBSSA
SBS-SA
-45.0*
SC-36
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Optional additional layers of base insulation; Min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
HA, GAF
2-Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 19 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
SC-37
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Optional additional layers of base insulation; Min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
HA, GAF
2-Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-38
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board
HA, GAF
2-Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-39
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per
1.6 ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
HA, GAF
2-Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
See
Note 2
1 per 4
ft2
Additional layer of base insulation
Hot
asphalt
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
VENTING SYSTEMS:
SC-40
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
COLD-APPLIED SYSTEMS:
SC-41
Min. 22 ga., Type B,
Grade 33 steel or
structural concrete
Min. 1.5-EnergyGuard RH
See
Note 2
1 per 2
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500,
LRF-M,
M-OSFA
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-37.5*
SC-42
Min. 22 ga., Type B,
Grade 33 steel or
structural concrete
Min. 2-EnergyGuard RH
See
Note 2
1 per
2.9 ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500,
LRF-M,
M-OSFA
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-37.5*
SC-43
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-45.0*
SC-44
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-45.0*
HYBRID HOT/COLD-APPLIED SYSTEMS:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 20 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Fasten
Top Insulation Layer
Roof Cover
Attach
Type
Attach
Base
HA
BP-AA or SBS-AA
Cap
MDP
(psf)
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
Ply
SC-45
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Optional additional layers base insulation followed
by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
SC-46
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation
See
Note 2
1 per
2.67 ft2
Optional additional layers base insulation followed
by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous) or min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
HA
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
SC-47
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation
See
Note 2
1 per
3.2 ft2
Optional additional layers base insulation followed
by min.0.5-inch EnergyGuard Perlite Recover Board,
min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
HA
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
1 per 4
ft2
Optional additional layers base insulation followed
by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
HA
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
HA
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
HA
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
SC-48
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation
See
Note 2
SC-49
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RH, EnergyGuard RN
See
Note 2
1 per
3.2 ft2
Optional additional layers base insulation followed
by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
SC-50
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Min. 0.25-inch Dens Deck, Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 21 of 76
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Fasten
Top Insulation Layer
Roof Cover
Attach
Type
HA
BP-AA or SBS-AA
See
Note 2
1 per
1.33 ft2
Optional additional layers base insulation followed
by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof Insulation
or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
Attach
Base
Cap
MDP
(psf)
(Optional) BPAA or SBS-AA
SBS-CA-1
-60.0
Ply
SC-51
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard Polyiso
Insulation, EnergyGuard
RH, EnergyGuard RN
SC-52
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2
ft2
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
SC-53
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 4
ft2
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 22 of 76
TABLE 2A-2: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Thermal Barrier
Type
Fastener
Attach
Temp Roof
Insulation Layer(s)
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
SELF-ADHERING SYSTEMS:
SC-54
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
SC-55
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
SC-56
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
SC-57
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
SC-58
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
SC-59
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
SBS-SA
None
SBS-SA
-45.0*
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-45.0*
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
followed by min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500
SBS-SA
None
SBS-SA
-45.0*
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
followed by min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500
SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-45.0*
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber
Roof Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-45.0*
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RH
followed by Min. 0.5-inch EnergyGuard
RH HD Polyiso Insulation, EnergyGuard
HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-45.0*
1 per
2.7 ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak
Barrier, self-adhered
Min. 1.5-inch EnergyGuard RH
followed by Min. 0.5-inch EnergyGuard
RH HD Polyiso Insulation, EnergyGuard
HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
SBS-CA or SBSCA-1
None
SBS-CA
or SBSCA-1
-45.0*
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
COLD-APPLIED SYSTEMS:
SC-60
Min. 22 ga.,
Type B, Grade 33
steel or
structural
concrete
Min. 0.625-inch min.
0.5-inch SECUROCK
Gypsum Fiber Roof
Board
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
See Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 23 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Roof Cover
Fasteners
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
SC-61
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 4 ft2
SBS-TA or APP-TA
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-30.0*
SC-62
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 3.2
ft2
SBS-TA or APP-TA
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-37.5*
SC-63
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.625-inch Dens Deck Prime
See Note 2
1 per 4 ft2
SBS-TA or APP-TA
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
SC-64
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2.13
ft2
SBS-TA or APP-TA
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
SC-65
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime
See Note 2
1 per 3.2
ft2
SBS-TA or APP-TA
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
SC-66
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck, Dens Deck Prime
See Note 2
1 per 4 ft2
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-67
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Fiber Base HD1 or Fiber Base
HD6
See Note 2
1 per 2.9
ft2
SBS-AA
(Optional) SBSAA
SBS-AA,
SBS-TA
-45.0*
SC-68
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or Structodek High
Density Fiberboard Roof Insulation
See Note 2
1 per 2 ft2
SBS-AA
(Optional) SBSAA
SBS-AA,
SBS-TA
-45.0*
SC-69
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 2 ft2
BP-AA, SBS-AA, SBS-TA
or APP-TA
(Optional) BPAA, SBS-AA,
SBS-TA or APPTA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
SC-70
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 4 ft2
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA
-45.0*
SC-71
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 1.6
ft2
SBS-AA, SBS-TA, APP-TA
(Optional) SBSAA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 24 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
Deck
(See Note 1)
Base Insulation Layer
SC-72
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-73
Min. 22 ga., type B, Grade
33 steel or structural
concrete
System
No.
Top Insulation Layer
Cap
MDP
(psf)
Fasteners
Attach
Base
Ply
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 1.45
ft2
SBS-AA, SBS-TA, APP-TA
(Optional) SBSAA, SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 1.78
ft2
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-52.5
SC-74
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
(#14 only)
1 per 1.78
ft2
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA or APPTA
SBS-AA,
SBS-TA or
APP-TA
-60.0
SC-75
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.33
ft2
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-76
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 2 ft2
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA
-60.0
SC-77
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
See Note 2
1 per 1 ft2
SBS-AA
(Optional) SBSAA or SBS-TA
SBS-AA,
SBS-TA
-67.5
SC-78
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber
Roof Board
See Note 2
1 per 1.33
ft2
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-67.5
SC-79
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.6
ft2
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA
-82.5
SC-80
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or
structural concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.6
ft2
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA
-90.0
SC-81
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1 ft2
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-97.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Type
Roof Cover
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 25 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
Deck
(See Note 1)
Base Insulation Layer
SC-82
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or
structural concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-83
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-84
System
No.
SC-85
Top Insulation Layer
Type
Roof Cover
Base
Ply
Cap
MDP
(psf)
Fasteners
Attach
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.45
ft2
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA
-97.5
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime
See Note 2
(#14 only)
1 per 1 ft2
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-105.0
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
(#14 only)
1 per 1 ft2
APP-TA
(Optional) APPTA
APP-TA
-105.0
Min. 22 ga., type B, Grade
33 steel or structural
concrete
Optional BP-AA or SBS-AA
vapor barrier over
concrete deck.
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
(#14 only)
1 per 1 ft2
SBS-TA
(Optional) SBSTA
SBS-TA,
APP-TA
-120.0
SELF-ADHERING SYSTEMS:
SC-86
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 3.2
ft2
SBS-SA
(Optional) SBSSA, SBS-TA,
APP-TA
SBS-SA,
SBS-TA,
APP-TA
-30.0*
SC-87
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 3.2
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-30.0*
SC-88
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 4 ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-30.0*
SC-89
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 3.2
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-37.5*
SC-90
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2.0-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or EnergyGuard Ultra
See Note 2
1 per 4 ft2
SBS-SA
(Optional) SBSSA, SBS-TA,
APP-TA
SBS-SA,
SBS-TA,
APP-TA
-37.5*
SC-91
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 4 ft2
SBS-SA or
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-37.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 26 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
Deck
(See Note 1)
Base Insulation Layer
SC-92
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-93
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-94
System
No.
Top Insulation Layer
Base
Ply
Cap
MDP
(psf)
Fasteners
Attach
Min. 0.375-inch SECUROCK Gypsum-Fiber
Roof Board
See Note 2
1 per 2.7
ft2
SBS-SA
(Optional) SBSSA, SBS-TA,
APP-TA
SBS-SA,
SBS-TA,
APP-TA
-45.0*
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 2 ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber
Roof Board
See Note 2
1 per 2.7
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-95
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2.13
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
SC-96
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime
See Note 2
1 per 3.2
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
SC-97
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.625-inch Dens Deck Prime
See Note 2
1 per 4 ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-45.0*
SC-98
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
See Note 2
1 per 2 ft2
SBS-SA or
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-99
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or EnergyGuard Ultra
See Note 2
1 per 2 ft2
SBS-SA
(Optional) SBSSA, SBS-TA,
APP-TA
SBS-SA,
SBS-TA,
APP-TA
-45.0*
SC-100
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2 ft2
SBS-SA or
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-101
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2.0-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
See Note 2
1 per 3.2
ft2
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
SC-102
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 3.2
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Type
Roof Cover
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 27 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
SC-103
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-104
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-105
Top Insulation Layer
Roof Cover
Cap
MDP
(psf)
(Optional) SBSSA
SBS-SA
-45.0*
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-52.5
1 per 1.6
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-52.5
See Note 2
1 per 1.78
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-52.5
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or EnergyGuard Ultra
See Note 2
1 per 1.33
ft2
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 1.33
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2.0-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or EnergyGuard Ultra
See Note 2
1 per 1.45
ft2
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-110
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 1.45
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-111
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 1.78
ft2
SBS-SA or
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-60.0
SC-112
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.33
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-60.0
SC-113
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
(#14 only)
1 per 1.78
ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-60.0
Fasteners
Attach
Min. 2.0-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or EnergyGuard Ultra
See Note 2
1 per 2 ft2
SBS-SA
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 1.45
ft2
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
SC-106
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof
Board
SC-107
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-108
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-109
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Type
Base
Ply
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 28 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
SC-114
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
SC-115
Top Insulation Layer
Roof Cover
Cap
MDP
(psf)
Type
Fasteners
Attach
Base
Ply
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 1.33
ft2
SBS-SA or
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-67.5
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber
Roof Board
See Note 2
1 per 1.33
ft2
SBS-SA or
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-67.5
SC-116
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1 ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-97.5
SC-117
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
(#14 only)
1 per 1 ft2
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-105.0
VENTING SYSTEMS:
SC-118
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 4 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-37.5*
SC-119
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 2 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-120
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-121
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2.0-inch EnergyGuard RH
See Note 2
1 per 2.9
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-122
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Ultra
See Note 2
1 per 3.2
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
SC-123
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2.5-inch EnergyGuard RA
See Note 2
1 per 4 ft2
B-LL
BP-AA, SBS-AA
SBS-AA
-45.0*
SC-124
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 3-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 3.2
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 29 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
SC-125
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-126
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-127
Top Insulation Layer
Roof Cover
Cap
MDP
(psf)
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-45.0*
B-LL
One or more
BP-AA, SBS-AA
SBS-AA
-45.0*
1 per 2 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-52.5
See Note 2
1 per 2 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-52.5
Min. 2.0-inch EnergyGuard Ultra
See Note 2
1 per 2 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-60.0
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 2 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-60.0
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 1.45
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-67.5
SC-132
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 3-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 1.6
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-67.5
SC-133
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 1.45
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-75.0
SC-134
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2.0-inch EnergyGuard Ultra
See Note 2
1 per 1.45
ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-75.0
SC-135
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
(ASTM
D6164,
polyester
only)
-82.5
Fasteners
Attach
Min. 3-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 3.2
ft2
B-LL
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 3-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 4 ft2
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation
See Note 2
SC-128
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard RH
SC-129
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-130
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-131
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Type
Min. 2-inch EnergyGuard Polyiso Insulation or
EnergyGuard RH
See Note 2
1 per 1.45
ft2
Base
Ply
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 30 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
SC-136
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-137
Min. 22 ga., type B, Grade
33 steel or structural
concrete
SC-138
Min. 22 ga., type B, Grade
33 steel or structural
concrete
Top Insulation Layer
Type
Roof Cover
Cap
MDP
(psf)
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-82.5
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-82.5
1 per 1 ft2
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-97.5
Fasteners
Attach
Base
Min. 3-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 1.6
ft2
B-LL
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck
See Note 2
1 per 1 ft2
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
Ply
COLD-APPLIED SYSTEMS:
SC-139
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
See Note 2
1 per 2 ft2
BP-CA
None
SBS-CA
-45.0*
SC-140
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
1 per 4 ft2
SBS-CA
None
SBS-CA
-45.0*
SC-141
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard RH or EnergyGuard
RN
See Note 2
1 per 2 ft2
SBS-CA-1
None
SBS-CA-1
-45.0*
SC-142
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 2-inch EnergyGuard RH or EnergyGuard
RN
See Note 2
1 per 2.9
ft2
SBS-CA-1
None
SBS-CA-1
-45.0*
SC-143
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 2 ft2
SBS-CA-1
None
SBS-CA-1
-45.0*
SC-144
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, min. 1.5-inch
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
See Note 2
1 per 2 ft2
SBS-CA or SBS-CA-1
None
SBS-CA or
SBS-CA-1
-45.0*
SC-145
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
(AccuTrac
Flat Plates
only)
1 per 1.33
ft2
SBS-CA-1
None
SBS-CA-1
-52.5
SC-146
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN, EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 1.33
ft2
SBS-CA-1
None
SBS-CA-1
-67.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 31 of 76
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
SC-147
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
SC-148
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
Top Insulation Layer
Type
Roof Cover
Cap
MDP
(psf)
None
SBS-CA-1
-67.5
SBS-CA-1
None
SBS-CA-1
-67.5
Fasteners
Attach
Base
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 1.78
ft2
SBS-CA-1
One or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber
Roof Board
See Note 2
1 per 1.33
ft2
Ply
HYBRID HOT/COLD-APPLIED SYSTEMS:
SC-149
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 4 ft2
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-45.0*
SC-150
Min. 22 ga., Type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
See Note 2
(AccuTrac
Flat Plates)
1 per 1.33
ft2
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-52.5
SC-151
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 2 ft2
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-60.0
SC-152
Min. 22 ga., type B, Grade
33 steel or structural
concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.6
ft2
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-82.5
SC-153
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or
structural concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.6
ft2
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-90.0
SC-154
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or
structural concrete
(Optional for recover) One
or more layers, any
combination, loose laid
Min. 0.5-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
See Note 2
1 per 1.45
ft2
BP-AA or SBS-AA
(Optional) BPAA or SBS-AA
SBS-CA-1
-97.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 32 of 76
TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Top Insulation Layer
Base Insulation Layer
Type
Roof Cover
Fasten
Attach
Base
Ply
Cap
MDP
(psf)
SELF-ADHERING SYSTEMS:
SC-155
Min. 22 ga., Type B,
Grade 33 steel or
structural concrete
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board, loose-laid,
covered with WeatherWatch XT Mat Surfaced Leak
Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier
or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RH, loose
laid, followed by min. 0.5-inch
EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
See
Note 2
1 per 2
ft2
SBS-SA or
WeatherWatch XT
Mat Surfaced Leak
Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-45.0*
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board, loose-laid,
covered with WeatherWatch XT Mat Surfaced Leak
Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier
or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RH, loose
laid, followed by min. 0.5-inch
EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
See
Note 2
1 per 2
ft2
SBS-CA or SBS-CA-1
None
SBS-CA
or SBSCA-1
-45.0*
COLD-APPLIED SYSTEMS:
SC-156
Min. 22 ga., Type B,
Grade 33 steel or
structural concrete
TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-2: BONDED AND MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Roof Cover
Adhesive & Fasteners
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
SC-157
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra, Loose-Laid
Min. 0.25inch Dens
Deck Prime
Adhesive: OB500
Fasteners: Drill-Tec XHD (steel
only) or Drill-Tec #14 HD
(concrete ony) & Drill-Tec Plates
Adhesive: 12-inch o.c.
Fasteners: 1 per 1.33 ft2
SBS-TA or APP-TA
(Optional) SBSTA or APP-TA
SBS-TA
or APPTA
-97.5
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra, Loose-Laid
Min. 0.25inch Dens
Deck Prime
Adhesive: OB500
Fasteners: Drill-Tec XHD (steel
only) or Drill-Tec #14 HD
(concrete ony) & Drill-Tec Plates
Adhesive: 12-inch o.c.
Fasteners: 1 per 1.33 ft2
SBS-SA or
WeatherWatch XT
Mat Surfaced Leak
Barrier
(Optional) SBSTA or APP-TA
SBS-TA
or APPTA
-97.5
SELF-ADHERING SYSTEMS:
SC-158
Min. 22 ga., type B,
Grade 33 steel or
structural concrete
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 33 of 76
TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Insulation Layer(s)
Base or Anchor Sheet
Base
Fasteners
Roof Cover
Attach
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
SC-159
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
24-inch o.c. at min. 2-inch laps
and 24-inch o.c. in two, equally
spaced, staggered center rows
BP-AA, SBSAA
SBS-AA
-30.0*
SC-160
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
18-inch o.c. at min. 2-inch laps
and 18-inch o.c. in two, equally
spaced, staggered center rows
BP-AA, SBSAA
SBS-AA
-37.5*
SC-161
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
18-inch o.c. at min. 2-inch laps
and 18-inch o.c. in three,
equally spaced, staggered
center rows
BP-AA, SBSAA
SBS-AA
-45.0*
SC-162
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
12-inch o.c. at min. 2-inch laps
and 18-inch o.c. in three,
equally spaced, staggered
center rows
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-45.0*
SC-163
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
12-inch o.c. at min. 3.5-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
SBS-AA
SBS-AA,
SBS-TA
-45.0*
SC-164
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Optional BP-AA or
SBS-AA vapor
barrier over
concrete deck.
One or more
layers, any
combination
insulation.
Ruberoid Mop Smooth, Ruberoid Mop Smooth
1.5, Ruberiod Mop Plus Smooth
See Note 2
18-inch o.c. at min. 3.5-inch laps
(Optional)
SBS-TA
SBS-TA
-45.0*
SC-165
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
See Note 2
18-inch o.c. at min. 3.5-inch laps
BP-AA, SBSAA
SBS-AA
-45.0*
SC-166
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
Drill-Tec 2 in. Barbed
Plates with Drill-Tec
#12 (steel only) or #14
Off-centered in the lap by 0.5inch towards the sheet-edge
and spaced 18-inch o.c. within
the min. 4-inch wide, heatwelded laps
(Optional)
SBS-TA
SBS-TA
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 34 of 76
TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base or Anchor Sheet
Insulation Layer(s)
Base
Fasteners
Roof Cover
Attach
Ply
Cap
MDP
(psf)
SC-167
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
Drill-Tec Batten Bar
with Drill-Tec #12
(steel only) or #14
18-inch o.c. within min. 4-inch
wide, heat-welded laps
(Optional)
SBS-TA
SBS-TA
-45.0*
SC-168
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid HW Smooth
Drill-Tec 2 in. Barbed
Plates with Drill-Tec
#12 (steel only) or #14
12-inch o.c. within min. 4-inch
wide, heat-welded laps
(Optional)
SBS-TA
SBS-TA
-45.0*
SC-169
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Optional BP-AA or
SBS-AA vapor
barrier over
concrete deck.
One or more
layers, any
combination
insulation
Ruberoid Mop Smooth, Ruberoid Mop Smooth
1.5, Ruberiod Mop Plus Smooth
See Note 2
12-inch o.c. at min. 3.5-inch laps
(Optional)
SBS-TA
SBS-TA
-52.5
SC-170
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
Drill-Tec 2 in. Barbed
Plates with Drill-Tec
#12 (steel only) or #14
Off-centered in the lap by 0.5inch towards the sheet-edge
and spaced 12-inch o.c. within
the min. 4-inch wide, heatwelded laps
(Optional)
SBS-TA
SBS-TA
-52.5
SC-171
Min. 22 ga., type B, Grade
33 steel
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
Drill-Tec 2-3/8 in.
Barbed XHD Plates or
Drill-Tec Eyehook
AccuSeam Plates with
Drill-Tec XHD
Off-centered in the lap by 0.25inch towards the sheet-edge
and spaced 12-inch o.c. within
the min. 5-inch wide, heatwelded laps
(Optional)
SBS-TA
SBS-TA
-67.5
SC-172
Min. 22 ga., type B, Grade
33 steel
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
Drill-Tec Batten Bar
with Drill-Tec XHD
12-inch o.c. within min. 4-inch
wide, heat-welded laps
(Optional)
SBS-TA
SBS-TA
-67.5
SC-173
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
6-inch o.c. at min. 3.5-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
SBS-AA
SBS-AA,
SBS-TA
-82.5
SC-174
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #80 Ultima Base Sheet
See Note 2
6-inch o.c. at min. 3.5-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-82.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 35 of 76
TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base or Anchor Sheet
Insulation Layer(s)
Base
Fasteners
Roof Cover
Attach
MDP
(psf)
Ply
Cap
6-inch o.c. at min. 3.5-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-82.5
BP-AA, SBSAA
SBS-AA
-105.0
See Note 2 (Drill-Tec 3”
Standard Steel Plate; DrillTec ASAP 3S (steel) or
Drill-Tec Heavy Duty ASAP
Roofing Fastener
Assembled with a 3”
Metal Plate only)
SC-175
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
SC-176
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
See Note 2
18-inch o.c. at min. 3.25-inch
laps and 18-inch o.c. in two,
equally spaced, staggered
center rows
SC-177
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Optional BP-AA or
SBS-AA vapor
barrier over
concrete deck.
One or more
layers, any
combination
insulation
Ruberoid Mop Smooth, Ruberoid Mop Smooth
1.5, Ruberiod Mop Plus Smooth
See Note 2
6-inch o.c. at min. 3.5-inch laps
(Optional)
SBS-TA
SBS-TA
-112.5
SC-178
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #80 Ultima Base Sheet
See Note 2
6-inch o.c. at min. 3.5-inch laps
and 6-inch o.c. in three, equally
spaced, staggered center rows
(Optional)
SBS-TA
SBS-TA
-150.0
SC-179
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
Drill-Tec #14 Fasteners
with Drill-Tec 2 3/8 in.
Barbed XHD Plates or
Drill-Tec Eyehook
AccuSeam Plates
6-inch o.c. at min. 3.25-inch laps
and 6-inch o.c. in three, equally
spaced, staggered center rows
SBS-TA
SBS-TA
-150.0
6-inch o.c. at min. 3.5-inch laps
and 6-inch o.c. in three, equally
spaced, staggered center rows
(Optional)
Ruberoid
HW
Smooth
SBS-TA
-150.0
GAFGLAS #75
See Note 2 (Drill-Tec 3”
SC-180
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75
Standard Steel Plate; DrillTec ASAP 3S (steel) or
Drill-Tec Heavy Duty ASAP
Roofing Fastener
Assembled with a 3”
Metal Plate only)
SELF-ADHERING SYSTEMS:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 36 of 76
TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base or Anchor Sheet
Insulation Layer(s)
Base
Fasteners
Roof Cover
Attach
Ply
Cap
MDP
(psf)
SC-181
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Liberty SBS Mechanically Attached Base Sheet
See Note 2
12-inch o.c. at min. 3.5-inch laps
and 18-inch o.c. in two, equally
spaced, staggered center rows
(Optional)
SBS-SA,
SBS-TA or
APP-TA
SBS-SA,
SBS-TA or
APP-TA
-30.0*
SC-182
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Liberty SBS Mechanically Attached Base Sheet
See Note 2
9-inch o.c. at min. 4-inch laps
and 9-inch o.c. in two, equally
spaced, staggered center rows
(Optional)
SBS-SA
SBS-SA
-37.5
SC-183
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Liberty SBS Self-Adhering Base/Ply Sheet
See Note 2
12-inch o.c. at min. 3.5-inch laps
and 18-inch o.c. in one center
row
(Optional)
SBS-SA
SBS-SA
-45.0*
COLD-APPLIED SYSTEMS:
SC-184
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
See Note 2
18-inch o.c. at min. 3-inch laps
None
SBS-CA or
SBS-CA-1
-30.0*
SC-185
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid 20 Smooth
See Note 2
12-inch o.c. at min. 3-inch laps
and 12-inch o.c. in two, equally
spaced, staggered center rows
None
SBS-CA or
SBS-CA-1
-45.0*
SC-186
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet
See Note 2
12-inch o.c. at min. 2-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
None
SBS-CA
-45.0*
SC-187
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
Ruberoid Mop Smooth 1.5
See Note 2
24-inch o.c. at min. 3-inch laps
and 24-inch o.c. in two, equally
spaced, staggered center rows
None
SBS-CA or
SBS-CA-1
-45.0
SC-188
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more
layers, any
combination
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
See Note 2
6-inch o.c. at min. 3.5-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
SBS-CA at
2.0 gal/sq.
SBS-CA at
2.0 gal/sq.
-82.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 37 of 76
TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY
C-1.
Primed
concrete
Min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous)
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-TA or
APP-TA
-140.0
C-2.
Primed
concrete
Min. 0.5-inch EnergyGuard Perlite Recover Board
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-TA or
APP-TA
-165.0
C-3.
Primed
concrete
Min. 0.5-inch Structodek High Density Fiberboard Roof
Insulation
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-TA or
APP-TA
-165.0
C-4.
Primed
concrete
Min. 1.5-inch EnergyGuard Composite
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA, SBS-AA
SBS-AA, SBS-TA or
APP-TA
-270.0
C-5.
Concrete
Min. 0.5-inch Structodek High Density Fiberboard Roof
Insulation
OB500
BP-AA, SBS-AA
(Optional) One or more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-TA or
APP-TA
-165.0
C-6.
Concrete
Min. 0.25-inch Dens Deck Prime
OB500
SBS-TA
(Optional) One or more SBS-TA
SBS-TA
-300.0
C-7.
Concrete
Min. 0.5-inch Structodek High Density Fiberboard Roof
Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-TA or
APP-TA
-165.0
C-8.
Concrete
Min. 0.25-inch Dens Deck Prime
GAF 2Part
SBS-TA
(Optional) One or more SBS-TA
SBS-TA
-245.0
SELF-ADHERING SYSTEMS WITH BASE INSULATION LAYER ONLY
C-9.
Primed
concrete
Min. 1.5-inch EnergyGuard Ultra
HA
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-SA, SBS-TA, APPTA
-90.0
C-10.
Primed
concrete
Min. 1.5-inch EnergyGuard RN
HA
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-TA, APP-TA
-210.0
C-11.
Primed
concrete
Min. 1.5-inch EnergyGuard RN
HA
WeatherWatch XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-210.0
C-12.
Primed
concrete
Min. 1.5-inch EnergyGuard RA
HA
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-TA, APP-TA
-217.5
C-13.
Primed
concrete
Min. 1.5-inch EnergyGuard RA
HA
WeatherWatch XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-217.5
C-14.
Concrete
Min 0.5-inch Structodek High Density Fiberboard Roof
Insulation
OB500, 6inch o.c.
SBS-SA
(Optional) SBS-SA
SBS-SA
-110.0
C-15.
Concrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
SBS-SA
(Optional) SBS-SA
SBS-SA
-120.0
C-16.
Concrete
Min. 0.25-inch Dens Deck
OB500
SBS-SA
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-122.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 38 of 76
TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-17.
Concrete
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-137.5
C-18.
Concrete
Min. 1-inch EnergyGuard RN
OB 500
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-162.5
C-19.
Concrete
Min. 0.25-inch Dens Deck primed with ASTM D41 primer
OB500
SBS-SA
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-167.5
C-20.
Concrete
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
OB500
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-232.5
C-21.
Concrete
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
primed with ASTM D41 primer
OB500
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-285.0
C-22.
Concrete
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA
SBS-TA
-300.0
C-23.
Concrete
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-232.5
C-24.
Concrete
Min. 1.5-inch EnergyGuard RN
GAF 2Part
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-TA, APP-TA
-210.0
C-25.
Concrete
Min. 1.5-inch EnergyGuard RN
GAF 2Part
WeatherWatch XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-210.0
C-26.
Concrete
Min. 1.5-inch EnergyGuard RA
GAF 2Part
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-TA, APP-TA
-217.5
C-27.
Concrete
Min. 1.5-inch EnergyGuard RA
GAF 2Part
WeatherWatch XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-217.5
C-28.
Concrete
Min. 0.25-inch Dens Deck Prime
GAF 2Part
WeatherWatch XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA
SBS-TA
-245.0
VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY
C-29.
Primed
concrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
HA
B-LL
(Optional) One or more BP-AA, SBS-AA
SBS-AA
-150.0
C-30.
Primed
concrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
HA
B-LL
One or more BP-AA, SBS-AA
SBS-TA or APP-TA
-150.0
C-31.
Primed
concrete
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
HA
B-LL
(Optional) BP-AA, SBS-AA
SBS-AA
-150.0
C-32.
Primed
concrete
Min. 0.5-inch EnergyGuard RN
HA
B-LL
SBS-AA
SBS-AA
-172.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 39 of 76
TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-33.
Primed
concrete
Min. 1.5-inch EnergyGuard Ultra
HA
B-LL
(Optional) One or more BP-AA, SBS-AA
SBS-AA
-172.5
C-34.
Primed
concrete
Min. 1.5-inch EnergyGuard Ultra
HA
B-LL
One or more BP-AA, SBS-AA
SBS-TA or APP-TA
-172.5
C-35.
Primed
concrete
Min. 1-inch EnergyGuard RN
HA
B-LL
One or more BP-AA, SBS-AA
SBS-AA
-292.5
OB500
SBS-CA-1
None
SBS-CA-1
-60.0
COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY
C-36.
Concrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or
EnergyGuard RN
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 40 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-37.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
HA
BP-AA
(Optional) BP-AA
SBS-AA or
SBS-TA
-112.5
C-38.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck Prime
HA
APP-TA
(Optional) APP-TA
APP-TA
-127.5
HA
BP-AA, SBS-AA
(Optional) BP-AA, SBSAA
SBS-AA
-150.0
C-39.
Primed
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation, EnergyGuard
Perlite Recover Board, min. 0.75-inch
EnergyGuard Perlite Roof Insulation, min.
0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum Fiber Roof Board
C-40.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-172.5
C-41.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.5-inch EnergyGuard Perlite Recover
Board
HA
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-187.5
C-42.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
HA
BP-AA or SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-43.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
SBS-TA
(Optional) SBS-TA
SBS-TA
-232.5
C-44.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
HA
APP-TA
(Optional) APP-TA
APP-TA
-240.0
C-45.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck or Dens Deck
Prime
HA
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof
Insulation or EnergyGuard Perlite Recover
Board, min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
BP-AA or SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
SBS-AA,
SBS-TA
-255.0
C-46.
Primed
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 41 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-47.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 1.5-inch EnergyGuard Composite
HA
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-270.0
C-48.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-307.5
C-49.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck or Dens Deck
Prime
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-150.0
C-50.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-165.0
C-51.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-187.5
C-52.
Concrete
Min. 1-inch EnergyGuard RH
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board, primed with Matrix™ 307
Premium Asphalt Primer
OB500
SBS-TA
(Optional) SBS-TA
SBS-TA
-210.0
C-53.
Concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-54.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
SBS-TA, APP-TA
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-240.0
C-55.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime
OB500
SBS-TA
(Optional) SBS-TA
SBS-TA
-300.0
C-56.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
C-57.
Concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
BP-AA or SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 42 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-58.
Concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
SBS-TA or APPTA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-232.5
C-59.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck or Dens Deck
Prime
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
SELF-ADHERING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER
C-60.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA
SBS-TA
-232.5
C-61.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
HA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) APP-TA
APP-TA
-240.0
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA or
APP-TA
SBS-TA or
APP-TA
-97.5
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-120.0
C-62.
Concrete
Min. 1.5-inch EnergyGuard RH
C-63.
Concrete
Min. 1-inch EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
C-64.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck
OB500
SBS-SA
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-122.5
C-65.
Concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-127.5
C-66.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-150.0
C-67.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
SBS-SA
(Optional) SBS-SA
SBS-SA
-152.5
C-68.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck; surface shall be
primed with ASTM D41 primer
OB500
SBS-SA
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-167.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 43 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Ply
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-232.5
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board (optional Matrix 307 Premium
Asphalt Primer)
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
Cap
MDP
(psf)
Base
C-69.
Concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
C-70.
Concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
(Optional) Additional layer(s) base
insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-232.5
C-71.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-240.0
C-72.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
SBS-SA
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-270.0
C-73.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board; surface shall be primed with
ASTM D41 primer
OB500
SBS-SA
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-285.0
C-74.
Concrete
Min. 1.5-inch EnergyGuard RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA or
APP-TA
SBS-TA or
APP-TA
-97.5
C-75.
Concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-127.5
C-76.
Concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board (optional Matrix 307 Premium
Asphalt Primer)
LRF-M
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-232.5
C-77.
Concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
(Optional) Additional layer(s) base
insulation
LRF-M
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-232.5
C-78.
Concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA or
APP-TA
SBS-TA or
APP-TA
-225.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 44 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-79.
Concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA or
APP-TA
SBS-TA or
APP-TA
-232.5
C-80.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck Prime
GAF 2Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBS-TA or
APP-TA
SBS-TA or
APP-TA
-240.0
VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-81.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-90.0
C-82.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-90.0
C-83.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
HA
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-90.0
C-84.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
HA
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-90.0
C-85.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
(Optional) EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
HA
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-150.0
C-86.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
(Optional) EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
HA
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-150.0
C-87.
Primed
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
HA
(Optional) EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
HA
B-LL
(Optional) BP-AA, SBSAA
SBS-AA
-150.0
C-88.
Primed
concrete
Min. 1.5-inch EnergyGuard Ultra
HA
(Optional) EnergyGuard Ultra
HA
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-172.5
C-89.
Primed
concrete
Min. 1.5-inch EnergyGuard Ultra
HA
(Optional) EnergyGuard Ultra
HA
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-172.5
C-90.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck or Dens Deck
Prime
HA
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-240.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 45 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-91.
Primed
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck or Dens Deck
Prime
HA
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-240.0
C-92.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-90.0
C-93.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-90.0
C-94.
Concrete
Min. 1.5-inch EnergyGuard Ultra
OB500
(Optional) EnergyGuard Ultra
OB500
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-150.0
C-95.
Concrete
Min. 1.5-inch EnergyGuard Ultra
OB500
(Optional) EnergyGuard Ultra
OB500
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-150.0
C-96.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck or Dens Deck
Prime
OB500
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-150.0
C-97.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck or Dens Deck
Prime
OB500
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-150.0
C-98.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
OB500
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-150.0
C-99.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
OB500
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-150.0
C-100.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-90.0
C-101.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-90.0
C-102.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
(Optional) EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
GAF 2Part
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-150.0
C-103.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
(Optional) EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
GAF 2Part
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-150.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 46 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-104.
Concrete
Min. 1.5-inch EnergyGuard Ultra
GAF 2Part
(Optional) EnergyGuard Ultra
GAF 2Part
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-172.5
C-105.
Concrete
Min. 1.5-inch EnergyGuard Ultra
GAF 2Part
(Optional) EnergyGuard Ultra
GAF 2Part
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-172.5
C-106.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch Dens Deck or Dens Deck
Prime
GAF 2Part
B-LL
(Optional) One or more
BP-AA, SBS-AA
SBS-AA
-240.0
C-107.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch Dens Deck or Dens Deck
Prime
GAF 2Part
B-LL
One or more BP-AA,
SBS-AA
SBS-TA or
APP-TA
-240.0
COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-108.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
SBS-CA
None
SBS-CA
-45.0
C-109.
Concrete
Min. 1.5-inch EnergyGuard RH
OB500,
LRF-M,
M-OSFA
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
OB500,
LRF-M,
M-OSFA
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-97.5
C-110.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
SBS-CA-1
None
SBS-CA-1
-127.5
C-111.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-172.5
C-112.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck Prime
GAF 2Part
SBS-CA-1
None
SBS-CA-1
-127.5
C-113.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
SBS-CA-1
None
SBS-CA-1
-172.5
HA
BP-AA or SBS-AA
(Optional) BP-AA or
SBS-AA
SBS-CA-1
-255.0
OB500
BP-AA or SBS-AA
(Optional) BP-AA or
SBS-AA
SBS-CA-1
-127.5
HYBRID COLD/HOT-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-114.
Primed
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogenenous), min. 0.5-inch
Structodek High Density Fiberboard Roof
Insulation or EnergyGuard Perlite Recover
Board, min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
C-115.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 47 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-116.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA or
SBS-AA
SBS-CA-1
-172.5
C-117.
Concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
BP-AA or SBS-AA
(Optional) BP-AA or
SBS-AA
SBS-CA-1
-240.0
CONVENTIONAL SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER:
C-118.
Concrete
Min. 1.0-inch Foamular 250 or 2.0-inch
STYROFOAM Deckmate Plus FA
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
SBS-TA, APP-TA
(Optional) SBS-TA, APPTA
SBS-TA,
APP-TA
-240.0
C-119.
Concrete
Min. 1.0-inch Foamular 250
OB500
Min. 0.25-inch Dens Deck or Dens Deck
Prime
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-277.5
C-120.
Concrete
Min. 1.5-inch, min. 1.25 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-87.5
C-121.
Concrete
Min. 1.5-inch, min. 1.25 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-87.5
C-122.
Concrete
Min. 1.5-inch, min. 1.5 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
C-123.
Concrete
Min. 1.5-inch, min. 1.5 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
C-124.
Concrete
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
C-125.
Concrete
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA, SBSAA, SBS-TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
Min. 0.25-inch Dens Deck Prime
OB500
SBS-SA
(Optional) SBS-SA
SBS-SA
-152.5
Min. 0.25-inch Dens Deck Prime
GAF 2Part
SBS-SA
(Optional) SBS-SA
SBS-SA
-87.5
SELF-ADHERING SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER:
C-126.
C-127.
Concrete
Min. 1.0-inch Foamular 250
OB500
Concrete
Min. 1.5-inch, min. 1.25 pcf ASTM C578
expanded polystyrene
GAF 2Part
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 48 of 76
TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
C-128.
Concrete
Min. 1.5-inch, min. 1.25 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board primed with D41 primer
GAF 2Part
SBS-SA
(Optional) SBS-SA
SBS-SA
-87.5
C-129.
Concrete
Min. 1.5-inch, min. 1.5 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck Prime
GAF 2Part
SBS-SA
(Optional) SBS-SA
SBS-SA
-152.5
C-130.
Concrete
Min. 1.5-inch, min. 1.5 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board primed with D41 primer
GAF 2Part
SBS-SA
(Optional) SBS-SA
SBS-SA
-180.0
C-131.
Concrete
Min. 1.5-inch, min. 2.0 pcf ASTM C578
expanded polystyrene
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board primed with D41 primer
GAF 2Part
SBS-SA
(Optional) SBS-SA
SBS-SA
-240.0
A.
The following are options for installation of a vapor barrier / temporary roof on the concrete deck prior to insulation placement. If asphaltic vapor barrier / temp roof is installed, concrete deck shall be primed with
Matrix™ 307 Premium Asphalt Primer or ASTM D41 primer prior to its installation. Unless otherwise noted, system Maximum Design Pressure (MDP) is unaffected. If noted, maximum design pressure (MDP) shall be
the lesser of that for the system in Table 3A, and that for the vapor barrier / insulation adhesive noted below:
1. For use with asphalt-applied insulation:
One or two plies BP-AA
One BP-AA base or ply sheet with SBS-AA, SBS-TA or APP-TA base or cap membrane
One or two plies SBS-AA, SBS-TA or APP-TA base and/or cap membrane
2. For use with OB500 applied insulation:
One or two plies BP-AA:
MDP -352.5 psf
Ruberoid 20 Smooth in Matrix™ 102 SBS Membrane Adhesive in full coverage:
MDP -202.5 psf
One ply Ruberoid Torch Smooth, Tri-Ply APP Smooth, Ruberoid HW 25 Smooth or Ruberoid HW Smooth:
MDP -165.0 psf
Deck primed with ASTM D41 primer followed by Liberty SBS Self-Adhering Base/Ply Sheet. The installed sheet is then heated
with a torch to burn-off any poly-film on the top surface
MDP -240.0 psf
UnderRoof HT High Temperature Leak Barrier, self-adhered:
MDP -37.5 psf
UnderRoof 2 Polyester-Surfaced Leak Barrier, self-adhered:
MDP -127.5 psf
3. For use with GAF 2-Part applied insulation:
One or two plies BP-AA:
MDP -262.5 psf
Optional BP-AA or SBS-AA with SBS-AA cap membrane:
MDP -270.0 psf
Optional BP-AA or SBS-AA, SBS-TA or APP-TA base membrane with SBS-TA or APP-TA cap membrane:
MDP -169.0 psf
Optional SBS-SA base membrane with SBS-SA cap membrane:
MDP -250.0 psf
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 49 of 76
TABLE 3A-3: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1A: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
System No.
Deck
(See
Note 1)
Base Insulation Layer
Temp Roof
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
C-132.
Primed
conc.
One or two plies of
GAFGLAS Ply 4, Tri-Ply Ply 4
or GAFGLAS FlexPly 6 in hot
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 1.4-inch EnergyGuard
Composite
HA
BP-AA or SBS-AA
BP-AA or
SBS-AA
SBS-AA
-202.5
C-133.
Primed
conc.
One or two plies of
GAFGLAS Ply 4, Tri-Ply Ply 4
or GAFGLAS FlexPly 6 in hot
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
HA
SBS-TA, APP-TA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-232.5
C-134.
Primed
conc.
SBS-CA, SBS-AA, SBS-TA or
APP-TA base ply
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-TA or APPTA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-165.0
C-135.
Primed
conc.
Liberty SA Self-Adhering
Base/Ply Sheet; poly-film
burned off
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-TA or APPTA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-240.0
SELF-ADHERING SYSTEMS:
C-136.
Primed
conc.
One or two plies of
GAFGLAS Ply 4, Tri-Ply Ply 4
or GAFGLAS FlexPly 6 in hot
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
HA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-232.5
C-137.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
(Optional) Additional layers base
insulation
OB500
SBS-SA
None
SBS-SA
-37.5
C-138.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
(Optional) Additional layers base
insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-37.5
C-139.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
SBS-SA
None
SBS-SA
-37.5
C-140.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-37.5
C-141.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-37.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 50 of 76
TABLE 3A-3: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1A: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
System No.
Deck
(See
Note 1)
Base Insulation Layer
Temp Roof
Type
Top Insulation Layer
Attach
Type
Roof Cover
Ply
Cap
MDP
(psf)
Attach
Base
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-37.5
C-142.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
C-143.
Primed
conc.
UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
(Optional) Additional layers base
insulation
OB500
SBS-SA
None
SBS-SA
-45.0
C-144.
Primed
conc.
UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-45.0
C-145.
Primed
conc.
UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-97.5
C-146.
Primed
conc.
UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
(Optional) Additional layers base
insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-127.5
C-147.
Primed
conc.
UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered
Min. 1-inch EnergyGuard RA, RH,
RN
OB500
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-127.5
C-148.
Primed
conc.
SBS-CA, SBS-AA, SBS-TA or
APP-TA base ply
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-165.0
C-149.
Primed
conc.
Liberty SA Self-Adhering
Base/Ply Sheet; poly-film
burned off
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA
-240.0
OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-37.5
COLD-APPLIED SYSTEMS:
C-150.
Primed
conc.
UnderRoof HT High
Temperature Leak Barrier,
self-adhered
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Min. 1.5-inch EnergyGuard RH
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 51 of 76
TABLE 3A-3: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1A: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
Deck
(See
Note 1)
Temp Roof
C-151.
Conc.
(optional
primer)
C-152.
Primed
conc.
System No.
Base Insulation Layer
Top Insulation Layer
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
Type
Attach
Ruberoid 20 Smooth
applied in Matrix™ 102 SBS
Membrane Adhesive at 1.52.0 gal/sq.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
SBS-CA
None
SBS-CA
-45.0
UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-97.5
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
HA
BP-AA or SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA-1
-232.5
HYBRID HOT/COLD-APPLIED SYSTEMS:
C-153.
Primed
conc.
One or two plies of
GAFGLAS Ply 4, Tri-Ply Ply 4
or GAFGLAS FlexPly 6 in hot
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 52 of 76
TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
Deck
(See Note 1)
System No.
Roof Cover
Primer
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
C-154.
Concrete
ASTM D41
APP-TA
(Optional) APP-TA
APP-TA
-90.0
C-155.
Concrete
ASTM D41
BP-AA, SBS-AA
BP-AA, SBS-AA
SBS-AA
-442.5
C-156.
Concrete
(Optional) ASTM D41
SBS-TA
(Optional) SBS-TA
SBS-TA
-465.0
SELF-ADHERING SYSTEMS:
C-157.
Concrete
ASTM D41
SBS-SA
(Optional) SBS-SA
SBS-SA
-72.5
C-158.
Concrete
ASTM D41
SBS-SA
(Optional) SBS-TA or APP-TA
SBS-TA or APP-TA
-140.0
Matrix™ 307 Premium Asphalt
Primer
B-LL
BP-AA, SBS-AA
SBS-AA
-185.0
VENTING SYSTEMS:
C-159.
Concrete
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 53 of 76
TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Struct.
Base Insulation Layer
LWC
Type
Coverboard
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-155.0
OB500
BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-225.0
OB500
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-225.0
Min. 2.0-inch, min. 1.0 pcf, ASTM
C578 expanded polystyrene
OB500
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
OB500
BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-120.0
Elastizell (min.
200 psi)
Min. 1.0-inch Foamular 250
OB500
Min. 0.25-inch Dens Deck or Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-225.0
Concrete
Elastizell (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-180.0
Concrete
Elastizell (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-180.0
LWC-8.
Concrete
Elastizell (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-222.5
LWC-9.
Concrete
Elastizell (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-222.5
Concrete
Min. 200 psi
Mearlcrete
LWIC
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-240.0
Concrete
Mearlcrete
(min. 300 psi)
Min. 0.5-inch Structodek TD
Concrete
Elastizell (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
LWC-3.
Concrete
Elastizell (min.
200 psi)
LWC-4.
Concrete
LWC-5.
LWC-6.
LWC-1.
LWC-2.
LWC-7.
LWC-10.
OB500
None
OB500
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
Elastizell (min.
200 psi)
Concrete
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
N/A
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 54 of 76
TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Deck (See Note 1)
Base Insulation Layer
Coverboard
System
No.
Struct.
LWC-11.
Concrete
Mearlcrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
Concrete
Elastizell,
Celcore or
Mearlcrete
(min. 200 psi)
Min. 1.5-inch, min. 1.25 pcf ASTM
C578 expanded polystyrene
GAF 2Part
LWC-13.
Concrete
Elastizell,
Celcore or
Mearlcrete
(min. 200 psi)
Min. 1.5-inch, min. 1.25 pcf ASTM
C578 expanded polystyrene
LWC-14.
Concrete
Elastizell,
Celcore or
Mearlcrete
(min. 200 psi)
LWC-15.
Type
Attach
Type
Roof Cover
Attach
MDP
(psf)
Base
Ply
Cap
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One or
more BP-AA, SBSAA, SBS-TA or APPTA
SBS-AA, SBSTA or APP-TA
-240.0
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-87.5
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-87.5
Min. 1.5-inch, min. 1.5 pcf ASTM
C578 expanded polystyrene
GAF 2Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-180.0
Concrete
Elastizell,
Celcore or
Mearlcrete
(min. 200 psi)
Min. 1.5-inch, min. 1.5 pcf ASTM
C578 expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-180.0
LWC-16.
Concrete
Celcore (min.
200 psi)
Min. 1.5-inch, min. 2.0 pcf ASTM
C578 expanded polystyrene
GAF 2Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-222.5
LWC-17.
Concrete
Celcore (min.
200 psi)
Min. 1.5-inch, min. 2.0 pcf ASTM
C578 expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-222.5
LWC-18.
Concrete
Mearlcrete
(min. 200 psi)
Min. 1.5-inch, min. 2.0 pcf ASTM
C578 expanded polystyrene
GAF 2Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-240.0
LWC-19.
Concrete
Mearlcrete
(min. 200 psi)
Min. 1.5-inch, min. 2.0 pcf ASTM
C578 expanded polystyrene
GAF 2Part
Min. 0.25-inch Dens Deck, Dens
Deck Prime or SECUROCK GypsumFiber Roof Board
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBSTA or APP-TA
-240.0
Mearlcrete
(min. 300 psi)
Min. 0.5-inch Structodek TD
OB500
None
N/A
SBS-SA
(Optional) SBS-SA
SBS-SA
-122.5
LWC-12.
LWC
SELF-ADHERING SYSTEMS:
LWC-20.
Concrete
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 55 of 76
TABLE 1B-1: LIGHTWEIGHT INSULATING CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Struct Deck
Anchor Sheet
Fasteners
Base Insulation
LWC
Type
Attach
Type
LWC-21.
Min. 22 ga.
type B,
Grade 33
vented
steel; 5-ft
spans or
structural
concrete
Celcore Cellular
Concrete (min.
300 psi) with
min. 1 pcf EPS
board and min.
2-inch thick top
coat
GAFGLAS #75
Base Sheet, TriPly #75 Base
Sheet, GAFGLAS
#80 Ultima Base
Sheet, Stratavent
Nailable Venting
Base Sheet
Drill-Tec
Base Sheet
Fastener
(1.7 in.)
7-inch o.c. at
the 3-inch lap
and 7-inch o.c.
in two equally
spaced,
staggered
center rows
Min. 1.5-inch
EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Polyiso Insulation
or EnergyGuard RH
Polyiso
LWC-22.
Min. 22 ga.
type B,
Grade 33
vented
steel; 5-ft
spans or
structural
concrete
Celcore Cellular
Concrete (min.
300 psi) with
min. 1 pcf EPS
board and min.
2-inch thick top
coat
GAFGLAS #75
Base Sheet, TriPly #75 Base
Sheet, GAFGLAS
#80 Ultima Base
Sheet, Stratavent
Nailable Venting
Base Sheet
Drill-Tec
Base Sheet
Fastener
(1.7 in.)
7-inch o.c. at
the 3-inch lap
and 7-inch o.c.
in two equally
spaced,
staggered
center rows
Min. 1.5-inch
EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Polyiso Insulation
or EnergyGuard RH
Polyiso
Celcore Cellular
Concrete (min.
300 psi) with
min. 1 pcf EPS
board and min.
2-inch thick top
coat
GAFGLAS #75
Base Sheet, TriPly #75 Base
Sheet, GAFGLAS
#80 Ultima Base
Sheet, Stratavent
Nailable Venting
Base Sheet
Drill-Tec
Base Sheet
Fastener
(1.7 in.)
7-inch o.c. at
the 3-inch lap
and 7-inch o.c.
in two equally
spaced,
staggered
center rows
Min. 1.5-inch
EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Polyiso Insulation
or EnergyGuard RH
Polyiso
Top Insulation
Attach
Type
Roof Cover
Attach
Base
MDP
(psf)
Ply
Cap
SBS-AA,
SBS-TA,
APP-TA
-75.0
CONVENTIONAL SYSTEMS:
HA
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous),
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board
HA
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
HA
Min. 0.25-inch Dens
Deck Prime or
SECUROCK
Gypsum-Fiber Roof
Board
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-75.0
HA
(Optional) Min.
0.25-inch
SECUROCK
Gypsum-Fiber Roof
Board
HA
B-LL
BP-AA,
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-75.0*
VENTING SYSTEMS:
LWC-23.
Min. 22 ga.
type B,
Grade 33
vented
steel; 5-ft
spans or
structural
concrete
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 56 of 76
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Structural
Base
LWC
Roof Cover
Attachment
Ply
Cap
MDP
(psf)
Membrane
Faster
Ruberoid Mop Plus Granule (granules
down)
Drill-Tec
Locking Impact
Nail
6-inch o.c. at min. 4-inch side
laps and 9-inch o.c. in two,
equally spaced staggered
center rows.
(Optional)
BP-AA, SBSAA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
Fasten through LWC to
structural deck 6-inch o.c.
within 4-inch heat welded side
laps
(Optional)
SBS-TA
SBS-TA
-52.5
CONVENTIONAL SYSTEMS:
Min. 22 ga. type B, Grade
33 vented steel; 6 ft spans
or structural concrete
Mearlcrete (min. 300 psi) with
min. 1 pcf EPS board and min. 2inch thick top coat
LWC-25.
Min. 22 ga. type B, Grade
33 steel; 6’-6”spans or
structural concrete
Min 250-300 psi Approved
cellular LWC with min. 1 pcf EPS
board and min. 2-inch thick top
coat
Ruberoid Mop Smooth
#14 HD DrillTec fasteners
and 2” Drill-Tec
Double-Barbed
Round Steel
Plates
LWC-26.
Min. 22 ga. type B, Grade
33 vented steel; 6 ft spans
or structural concrete
Mearlcrete (min. 300 psi) with
min. 1 pcf EPS board and min. 2inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.2 in.)
7.5-inch o.c. at min. 4-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
(Optional)
BP-AA, SBSAA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-27.
Structural concrete
Mearlcrete (min. 300 psi) with
optional min. 1 pcf Corrugated
EPS Holey Board and min. 2-inch
thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
4-inch o.c. at min. 4-inch laps
and 7-inch o.c. in two, equally
spaced, staggered center rows
SBS-TA
SBS-TA
-52.5
LWC-28.
Min. 22 ga. type B, Grade
33 vented steel; 6 ft spans
or structural concrete
Mearlcrete (min. 742 psi) min. 2inch thick top coat
GAFGLAS FlexPly 6
Drill-Tec Base
Sheet Fastener
(1.2)
7-inch o.c. at min. 4-inch side
laps and 7-inch o.c. in two,
equally spaced staggered
center rows.
(Optional)
BP-AA, SBSAA
SBS-AA
(polyester
reinforced,
D6164
only)
-52.5
LWC-29.
Min. 22 ga. type B, Grade
33 steel; 6 ft spans or
structural concrete
Min 250-300 psi Approved
cellular LWC with min. 1 pcf EPS
board and min. 2-inch thick top
coat
GAFGLAS FlexPly 6
See Note 2
Fasten through LWC to
structural deck 12-inch o.c. at
4-inch side laps and 12-inch
o.c. in two, equally spaced
staggered center rows.
(Optional)
BP-AA, SBSAA
SBS-AA,
SBS-TA
-67.5
LWC-30.
Min. 22 ga. type B, Grade
33 vented steel; 5-ft spans
or structural concrete
Celcore Cellular Concrete (min.
200 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
Ruberoid Mop Granule, Tri-Ply SBS
Granule (granules down)
Drill-Tec
Locking Impact
Nail
7-inch o.c. at min. 4-inch side
laps and 7-inch o.c. in two,
equally spaced staggered
center rows.
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-75.0
LWC-24.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 57 of 76
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Base
Roof Cover
Cap
MDP
(psf)
Two plies
BP-AA or
SBS-AA
SBS-AA
-75.0
See Note 2
Fasten through LWC to
structural deck 12-inch o.c. at
4-inch side laps and 12-inch
o.c. in two, equally spaced
staggered center rows.
(Optional)
SBS-TA
SBS-TA
(polyester,
D6164
only)
-97.5
GAFGLAS FlexPly 6
Drill-Tec Base
Sheet Fastener
(1.2 in.)
7-inch o.c. at min. 4-inch laps
and 7-inch o.c. in two, equally
spaced, staggered center rows
(Optional)
BP-AA, SBSAA
SBS-AA
(polyester,
D6164
only)
-127.5
Mearlcrete (min. 300 psi) with
min. 1 pcf EPS board and min. 2inch thick top coat
StormSafe Anchor Sheet
Drill-Tec Base
Sheet Fastener
(1.2 in.)
7.5-inch o.c. at min. 4-inch laps
and 12-inch o.c. in three,
equally spaced, staggered
center rows
(Optional)
SBS-SA
SBS-SA
-52.5
LWC-35.
Min. 22 ga., type B, Grade
33 steel; 6 ft spans or
structural concrete
Celcore Cellular Concrete (min.
300 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
12-inch o.c. at min. 2-inch side
laps and 12-inch o.c. at three
equally spaced staggered
center rows.
BP-AA or
SBS-AA
SBS-CA-1
-45.0
LWC-36.
Min. 22 ga., type B, Grade
33 steel; 6 ft spans or
structural concrete
Celcore Cellular Concrete (min.
300 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
9-inch o.c. at min. 2-inch side
laps and 9-inch o.c. at two
equally spaced staggered
center rows.
BP-AA or
SBS-AA
SBS-CA-1
-45.0
LWC-37.
Min. 22 ga., type B, Grade
33 steel; 6 ft spans or
structural concrete
Celcore Cellular Concrete (min.
300 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
7.5-inch o.c. at min. 2-inch side
laps and 7.5-inch o.c. at one
center row.
BP-AA or
SBS-AA
SBS-CA-1
-45.0
Structural
LWC
Membrane
Faster
LWC-31.
Min. 22 ga. type B, Grade
33 vented steel; 5-ft spans
or structural concrete
Celcore Cellular Concrete (min.
300 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
7-inch o.c. at min. 3-inch side
laps and 7-inch o.c. in two,
equally spaced staggered
center rows.
LWC-32.
Min. 22 ga. type B, Grade
33 steel; 5-ft spans or
structural concrete
Min 250 psi Approved cellular
LWC with optional min. 1 pcf EPS
board and min. 2-inch thick top
coat
Ruberoid HW Granule (granules
down)
Min. 22 ga. type B, Grade
33 steel; 6-ft spans or
structural concrete
Mearlcrete (min. 300 psi) with no
EPS board. Note: To qualify the
Mearlcrete under this assembly, a
Drill-Tec Base Sheet Fastener (1.2
in.) shall achieve an average
withdrawal of 146 lbf or greater
when tested per TAS105 or
ANSI/SPRI FX-1
LWC-33.
Attachment
Ply
SELF-ADHERING SYSTEMS:
LWC-34.
Min. 22 ga. type B, Grade
33 vented steel; 6 ft spans
or structural concrete
HYBRID HOT/COLD-APPLIED SYSTEMS:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 58 of 76
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Base
Roof Cover
Attachment
Ply
Cap
MDP
(psf)
Structural
LWC
Membrane
Faster
LWC-38.
Min. 22 ga., type B, Grade
33 steel; 6 ft spans or
structural concrete
Celcore Cellular Concrete (min.
300 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
9-inch o.c. at min. 3-inch side
laps and 18-inch o.c. at two
equally spaced staggered
center rows.
BP-AA or
SBS-AA
SBS-CA-1
-45.0
LWC-39.
Min. 22 ga., type B, Grade
33 steel; 5 ft spans or
structural concrete
Celcore Cellular Concrete (min.
300 psi) with min. 1 pcf EPS board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Drill-Tec Base
Sheet Fastener
(1.7)
7-inch o.c. at min. 3-inch side
laps and 7-inch o.c. at two
equally spaced staggered
center rows.
BP-AA or
SBS-AA
SBS-CA-1
-75.0
TABLE 4D: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System No.
Deck (See Note 1)
Structural
Primer
LWC
Roof Cover
Base
Ply
Cap
MDP
(psf)
SELF-ADHERING SYSTEMS:
LWC-40.
Concrete
Min. 250-300 psi Celcore LWIC
ASTM D41
SBS-SA
None
SBS-TA
-52.5
LWC-41.
Concrete
Min. 250-300 psi Celcore LWIC
TOPCOAT PRECOTE
SBS-SA
None
SBS-TA
-100.0
LWC-42.
Concrete
Min. 250-300 psi Elastizell LWIC
ASTM D41
SBS-SA
None
SBS-SA
-137.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 59 of 76
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
CWF-1.
Tectum
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
CWF-2.
Tectum
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
OB500
BP-AA, SBS-AA, SBS-TA or
APP-TA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
CWF-3.
Tectum
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
CWF-4.
Tectum
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
BP-AA, SBS-AA, SBS-TA or
APP-TA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
SELF-ADHERING SYSTEMS:
CWF-5.
Tectum
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
OB500
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA or APPTA
SBS-TA or
APP-TA
-45.0
CWF-6.
Tectum
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck, Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA or APPTA
SBS-TA or
APP-TA
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 60 of 76
TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note
1)
Anchor Sheet
Base Insulation
Type
Fasteners
Attach
Tectum
GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, #80
Ultima Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking
Impact Nail
Tectum
GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, #80
Ultima Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking
Impact Nail
9-inch o.c. at the 3inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, #80
Ultima Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking
Impact Nail
9-inch o.c. at the 3inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
Type
Attach
Top Insulation
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
CWF-7.
CWF-8.
9-inch o.c. at the 3inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
(Optional)
Min. 1-inch
EnergyGuard
(Optional)
Min. 1-inch
EnergyGuard
HA
Min. 0.25-inch Dens
Deck, Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
HA
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
HA
Min. 0.25-inch Dens
Deck, Dens Deck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
HA
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBSAA, SBS-TA,
APP-TA
SBS-TA,
APP-TA
-82.5
HA
BP-AA,
SBS-AA
(Optional)
BP-AA, SBSAA, SBS-TA,
APP-TA
SBS-TA,
APP-TA
-82.5
HA
Weather
Watch XT
Mat
Surfaced
Leak
Barrier
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA
-82.5
SELF-ADHERING SYSTEMS:
CWF-9.
Tectum
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
(Optional)
Min. 1-inch
EnergyGuard
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 61 of 76
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Base Sheet
Deck
(See Note 1)
Type
Roof Cover
Faster
Attachment
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
CWF-10.
Tectum
GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6, GAFGLAS #80 Ultima
Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet
Drill-Tec LD Fasteners and
Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12inch o.c. in two, equally spaced,
staggered center rows
(Optional) BPAA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA
-30.0
CWF-11.
Tectum
Ruberoid 20 Smooth
Drill-Tec LD Fasteners and
Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12inch o.c. in two, equally spaced,
staggered center rows
(Optional) BPAA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA
-60.0
CWF-12.
Tectum
Ruberoid HW 25 Smooth
Drill-Tec LD Fasteners and
Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12inch o.c. in two, equally spaced,
staggered center rows
(Optional) SBSTA
SBS-TA
-60.0
CWF-13.
Tectum
GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6, GAFGLAS #80 Ultima
Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or
Ruberoid 20 Smooth
Drill-Tec LD Fasteners and
Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7inch o.c. in two, equally spaced,
staggered center rows
(Optional) BPAA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA
-67.5
CWF-14.
Tectum
Ruberoid HW 25 Smooth
Drill-Tec LD Fasteners and
Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7inch o.c. in two, equally spaced,
staggered center rows
(Optional) SBSTA
SBS-TA
-67.5
CWF-15.
Tectum
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base
Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth,
Mop Smooth
Min. 1.8-inch Drill-Tec
Locking Impact Nail
9-inch o.c. at the 3-inch lap and 18inch o.c. in two, equally spaced,
staggered center rows
BP-AA, SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-82.5
Min. 1.8-inch Drill-Tec
Locking Impact Nail
9-inch o.c. at the 2-inch lap and 9inch o.c. at two, equally spaced,
staggered center rows
BP-AA or SBS-AA
SBS-CA-1
-45.0*
HYBRID HOT/COLD-APPLIED SYSTEMS:
CWF-16.
Tectum
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80
Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 62 of 76
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Deck
(See Note 1)
System
No.
Type
Top Insulation Layer
Attach
Roof Cover
Type
Attach
Base
Ply
Cap
MDP
(psf)
G-1.
Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard
RH
OB500
(Optional) Additional layer(s) of base
insulation
OB500
SBS-SA
None
SBS-SA
-87.5
G-2.
Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard
RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-105.0
G-3.
Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard
RN
OB500
(Optional) Additional layer(s) of base
insulation
OB500
SBS-SA or WeatherWatch XT
Mat Surfaced Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-147.5
G-4.
Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard
RH
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
SBS-TA
(Optional) SBSTA
SBS-TA
-190.0
Cap
MDP
(psf)
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Anchor Sheet
Type
Fasteners
Base Insulation
Attach
Type
Top Insulation
Attach
Type
Roof Cover
Attach
Base
Ply
VENTING SYSTEMS:
G-5.
Existing sound
gypsum or
gypsum plank
GAFGLAS #75 Base
Sheet, Tri-Ply #75 Base
Sheet, GAFGLAS #80
Ultima Base Sheet,
GAFGLAS Stratavent
Nailable Venting Base
Sheet
G-6.
Existing sound
gypsum or
gypsum plank
GAFGLAS Stratavent
Nailable Venting Base
Sheet
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Min. 1.8-inch
Drill-Tec Locking
Impact Nail or
Drill-Tec Base
Sheet Fastener
(1.2 in)
9-inch o.c. at the 2inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Min. 1.8-inch
Drill-Tec Locking
Impact Nail
9-inch o.c. at the 2inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
HA
Min. 0.5-inch
EnergyGuard Perlite
Recover Board or
min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
HA
BP-AA
or SBSAA
BP-AA,
SBS-AA
SBS-AA
or SBSTA
-45.0*
HA
None
N/A
B-LL
Two
plies
SBS-AA
SBS-AA
-45.0*
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 63 of 76
TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
G-7.
Deck
(See Note 1)
Base Insulation Layer
Existing sound gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Top Insulation Layer
Type
Fasteners
Min. 0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Drill-Tec Polymer Gyptec
Fastener with Drill-Tec
Gyptec Plate
Roof Cover
Attach
1 per 1.3 ft2
Base
Ply
Cap
(Optional) BPAA, SBS-AA or
SBS-TA
BP-AA or
SBS-AA
SBS-AA or
SBS-TA
MDP
(psf)
-62.5*
TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Base Sheet
Deck
(See Note 1)
Type
Faster
Roof Cover
Attachment
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS:
G-8.
Existing sound gypsum
or gypsum plank
GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BPAA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA
-30.0
G-9.
Existing sound gypsum
or gypsum plank
GAFGLAS Stratavent Nailable Venting Base Sheet
Drill-Tec Locking Impact
Nail
9-inch o.c. at min. 2-inch laps and 18-inch o.c. in
two, equally spaced, staggered center rows
BP-AA, SBS-AA
SBS-AA, SBSTA or APP-TA
-45.0*
G-10.
Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet
Drill-Tec Base Sheet
Fastener (1.2 in.)
9-inch o.c. at min. 2-inch laps and 18-inch o.c. in
two, equally spaced, staggered center rows
SBS-TA
SBS-TA
-45.0*
G-11.
Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Base Sheet
Fastener (1.2 in.)
9-inch o.c. at min. 2-inch laps and 12-inch o.c. in
two, equally spaced, staggered center rows
(Optional) BPAA, SBS-AA, SBSTA or APP-TA
SBS-AA, SBSTA or APP-TA
-50.0*
G-12.
Existing sound gypsum
or gypsum plank
Ruberoid 20 Smooth
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BPAA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA
-60.0
G-13.
Existing sound gypsum
or gypsum plank
Ruberoid HW 25 Smooth
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) SBSTA
SBS-TA
-60.0
G-14.
Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Base Sheet
Fastener (1.2 in.)
9-inch o.c. at min. 2-inch laps and 9-inch o.c. in
three, equally spaced, staggered center rows
(Optional) BPAA, SBS-AA, SBSTA or APP-TA
SBS-AA, SBSTA or APP-TA
-57.5*
G-15.
Existing sound gypsum
or gypsum plank
GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS
Stratavent Nailable Venting Base Sheet or
Ruberoid 20 Smooth
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BPAA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA
-67.5
G-16.
Existing sound gypsum
or gypsum plank
Ruberoid HW 25 Smooth
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered center rows
(Optional) SBSTA
SBS-TA
-67.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 64 of 76
TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Base Sheet
Deck
(See Note 1)
Type
Faster
Roof Cover
Attachment
Ply
Cap
MDP
(psf)
HYBRID HOT/COLD-APPLIED SYSTEMS:
G-17.
Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Locking Impact
Nail
9-inch o.c. at min. 2-inch laps and 18-inch o.c. at
two, equally spaced, staggered center rows
BP-AA or SBS-AA
SBS-CA-1
-45.0*
G-18.
Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Locking Impact
Nail
7.5-inch o.c. at min. 2-inch laps and 7.5-inch o.c. at
one center rows
BP-AA or SBS-AA
SBS-CA-1
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 65 of 76
TABLE 7A-1: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(See Notes 1 & 11)
Base Insulation Layer
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY
R-1.
Existing asphaltic roof cover
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA,
SBS-AA, SBS-TA or APP-TA
SBS-AA, SBS-TA
or APP-TA
-140.0
R-2.
Existing asphaltic roof cover
Min. 0.5-inch EnergyGuard Perlite Recover
Board
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA,
SBS-AA, SBS-TA or APP-TA
SBS-AA, SBS-TA
or APP-TA
-165.0
R-3.
Existing asphaltic roof cover
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA,
SBS-AA, SBS-TA or APP-TA
SBS-AA, SBS-TA
or APP-TA
-165.0
R-4.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard Composite
HA
BP-AA, SBS-AA
(Optional) One or more BP-AA,
SBS-AA
SBS-AA, SBS-TA
or APP-TA
-240.0
R-5.
Existing granule surface cap sheet
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
HA
SBS-TA, APP-TA
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-240.0
R-6.
Existing asphaltic roof cover
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
BP-AA, SBS-AA
(Optional) One or more BP-AA,
SBS-AA, SBS-TA or APP-TA
SBS-AA, SBS-TA
or APP-TA
-120.0
R-7.
Existing asphaltic roof cover
Min. 0.25-inch Dens Deck Prime
OB500
SBS-TA
(Optional) One or more SBS-TA
SBS-TA
-120.0
R-8.
Existing granule surface cap sheet
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500, 6inch o.c.
SBS-TA, APP-TA
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-240.0
R-9.
Existing asphaltic roof cover
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One or more BP-AA,
SBS-AA, SBS-TA or APP-TA
SBS-AA, SBS-TA
or APP-TA
-165.0
R-10.
Existing asphaltic roof cover
Min. 0.25-inch Dens Deck Prime
GAF 2Part
SBS-TA
(Optional) SBS-TA
SBS-TA
-245.0
SELF-ADHERING SYSTEMS WITH BASE INSULATION LAYER ONLY
R-11.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard Ultra
HA
SBS-SA
(Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, SBS-TA,
APP-TA
-90.0
R-12.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RN
HA
SBS-SA
(Optional) SBS-SA, SBS-TA,
APP-TA
SBS-TA, APP-TA
-210.0
R-13.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RN
HA
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-210.0
R-14.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA
HA
SBS-SA
(Optional) SBS-SA, SBS-TA,
APP-TA
SBS-TA, APP-TA
-217.5
R-15.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA
HA
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-217.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 66 of 76
TABLE 7A-1: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(See Notes 1 & 11)
Base Insulation Layer
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-16.
Existing granule surface cap sheet
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
HA
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-240.0
R-17.
Existing smooth surfaced BUR / APP
modified bitumen or granule surface
roof cover over structural concrete deck
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
SBS-SA or WeatherWatch
XT Mat Surfaced Leak
Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APPTA
-97.5
R-18.
Existing asphaltic roof cover
Min 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500, 6inch o.c.
SBS-SA
(Optional) SBS-SA
SBS-SA
-110.0
R-19.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
OB500
SBS-SA
(Optional) SBS-SA
SBS-SA
-120.0
R-20.
Existing asphaltic roof cover
Min. 0.25-inch Dens Deck
OB500
SBS-SA
(Optional) SBS-TA or APP-TA
SBS-TA or APPTA
-120.0
R-21.
Existing asphaltic roof cover
Min. 0.25-inch Dens Deck primed with ASTM
D41 primer
OB500
SBS-SA
(Optional) SBS-TA or APP-TA
SBS-TA or APPTA
-120.0
R-22.
Existing asphaltic roof cover
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-SA or WeatherWatch
XT Mat Surfaced Leak
Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APPTA
-120.0
R-23.
Existing asphaltic roof cover
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board primed with ASTM D41 primer
OB500
SBS-SA
(Optional) SBS-TA or APP-TA
SBS-TA or APPTA
-120.0
R-24.
Existing asphaltic roof cover
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA
SBS-TA
-120.0
R-25.
Existing smooth- or granule-surface BUR
or modified bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
OB500
SBS-SA or WeatherWatch
XT Mat Surfaced Leak
Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-225.0
R-26.
Existing granule surface cap sheet
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500, 6inch o.c.
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-240.0
R-27.
Existing smooth-surface BUR over
concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, MOSFA
SBS-SA or WeatherWatch
XT Mat Surfaced Leak
Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-75.0
R-28.
Existing smooth surfaced BUR or granule
surface roof cover
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M, MOSFA
SBS-SA or WeatherWatch
XT Mat Surfaced Leak
Barrier
(Optional) SBS-TA or APP-TA
SBS-TA or APPTA
-75.0
R-29.
Existing granule-surface BUR or modified
bitumen or smooth-surface SBS modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, MOSFA
SBS-SA or WeatherWatch
XT Mat Surfaced Leak
Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-225.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 67 of 76
TABLE 7A-1: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(See Notes 1 & 11)
Base Insulation Layer
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-30.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RN
GAF 2Part
SBS-SA
(Optional) SBS-SA, SBS-TA,
APP-TA
SBS-TA, APP-TA
-210.0
R-31.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RN
GAF 2Part
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-210.0
R-32.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA
GAF 2Part
SBS-SA
(Optional) SBS-SA, SBS-TA,
APP-TA
SBS-TA, APP-TA
-217.5
R-33.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA
GAF 2Part
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA, APP-TA
SBS-TA, APP-TA
-217.5
R-34.
Existing asphaltic roof cover
Min. 0.25-inch Dens Deck Prime
GAF 2Part
WeatherWatch XT Mat
Surfaced Leak Barrier
(Optional) SBS-TA
SBS-TA
-245.0
VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY
R-35.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
HA
B-LL
(Optional) One or more BP-AA,
SBS-AA
SBS-AA
-150.0
R-36.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
HA
B-LL
One or more BP-AA, SBS-AA
SBS-TA or APPTA
-150.0
R-37.
Existing smooth- or granule-surface BUR,
granule-surface modified bitumen or
smooth-surface SBS modified bitumen
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
HA
B-LL
(Optional) One or more BP-AA,
SBS-AA
SBS-AA
-150.0
R-38.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard Ultra
HA
B-LL
(Optional) One or more BP-AA,
SBS-AA
SBS-AA
-172.5
R-39.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard Ultra
HA
B-LL
One or more BP-AA, SBS-AA
SBS-TA or APPTA
-172.5
R-40.
Existing smooth- or granule-surface BUR
or modified bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
OB500
B-LL
(Optional) One or more BP-AA,
SBS-AA
SBS-AA
-225.0
R-41.
Existing smooth-surface BUR over
concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, MOSFA
B-LL
(Optional) One or more BP-AA,
SBS-AA
SBS-AA
-75.0
R-42.
Existing granule-surface BUR or modified
bitumen or smooth-surface SBS modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, MOSFA
B-LL
(Optional) One or more BP-AA,
SBS-AA
SBS-AA
-225.0
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
HA
SBS-CA-1
None
SBS-CA-1
-127.5
COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY
R-43.
Existing mineral surface cap or asphalt
BUR
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 68 of 76
TABLE 7A-1: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-44.
Existing mineral surface cap
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
HA
SBS-CA-1
None
SBS-CA-1
-172.5
R-45.
Existing smooth APP, mineral surface cap
or asphaltic BUR
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
OB500
SBS-CA-1
None
SBS-CA-1
-60.0
R-46.
Existing smooth surfaced BUR / APP
modified bitumen or granule surface
roof cover over structural concrete deck
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
SBS-CA or SBS-CA-1
None
SBS-CA or SBSCA-1
-97.5
R-47.
Existing asphalt BUR
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-120.0
R-48.
Existing smooth APP or mineral surface
cap
Min. 0.25-inch Dens Deck Prime
OB500
SBS-CA-1
None
SBS-CA-1
-127.5
R-49.
Existing smooth APP
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-CA-1
None
SBS-CA-1
-165.0
R-50.
Existing mineral surface cap
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-CA-1
None
SBS-CA-1
-172.5
R-51.
Existing smooth surfaced BUR or granule
surface roof cover
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M, MOSFA
SBS-CA or SBS-CA-1
None
SBS-CA or SBSCA-1
-75.0
HYBRID HOT/COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY
R-52.
Existing mineral surface cap or asphalt
BUR
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
HA
BP-AA or SBS-AA
(Optional) BP-AA or SBS-AA
SBS-CA-1
-127.5
R-53.
Existing mineral surface cap
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
HA
BP-AA or SBS-AA
(Optional) BP-AA or SBS-AA
SBS-CA-1
-172.5
R-54.
Existing asphalt BUR
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA or SBS-AA
SBS-CA-1
-120.0
R-55.
Existing smooth APP or mineral surface
cap
Min. 0.25-inch Dens Deck Prime
OB500
BP-AA or SBS-AA
(Optional) BP-AA or SBS-AA
SBS-CA-1
-127.5
R-56.
Existing smooth APP
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA or SBS-AA
SBS-CA-1
-165.0
R-57.
Existing mineral surface cap
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA or SBS-AA
SBS-CA-1
-172.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 69 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
CONVENTIONAL SYSTEMS (BASE AND TOP LAYER INSULATION):
R-58.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof
Board
HA
BP-AA
(Optional) BP-AA
SBS-AA or
SBS-TA
-112.5
R-59.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-127.5
R-60.
Existing smooth- or granulesurface BUR, granule-surface
modified bitumen or smoothsurface SBS modified bitumen
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation, EnergyGuard
Perlite Recover Board, min. 0.75-inch
EnergyGuard Perlite Roof Insulation, min.
0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum Fiber Roof Board
HA
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA
-150.0
R-61.
Existing granule surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
SBS-TA, APP-TA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-172.5
R-62.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-172.5
R-63.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.5-inch EnergyGuard Perlite
Recover Board
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-187.5
R-64.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
HA
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA, SBSTA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
R-65.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
SBS-TA
(Optional) SBSTA
SBS-TA
-232.5
R-66.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
HA
APP-TA
(Optional) APPTA
APP-TA
-240.0
R-67.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or Min. 1.5inch EnergyGuard Composite or min.
0.25-inch Dens Deck Prime
HA
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 70 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
OB500
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
OB500
Min. 0.25-inch Dens Deck or Dens Deck
Prime
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-150.0
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation, min. 0.25-inch
Dens Deck, Dens Deck Prime, SECUROCK
Gypsum Fiber Roof Board
OB500
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA
-150.0
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-165.0
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-165.0
R-74.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA or
EnergyGuard RN
OB500,
6-inch
o.c.
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
6-inch
o.c.
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
R-75.
Existing smooth-surface BUR
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M,
M-OSFA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation, min. 0.25-inch
Dens Deck, Dens Deck Prime, SECUROCK
Gypsum Fiber Roof Board
LRF-M,
M-OSFA
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA
-75.0
R-76.
Existing granule-surface BUR or
modified bitumen or smoothsurface SBS modified bitumen
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M,
M-OSFA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation, min. 0.25-inch
Dens Deck, Dens Deck Prime, SECUROCK
Gypsum Fiber Roof Board
LRF-M,
M-OSFA
BP-AA, SBS-AA
(Optional) BPAA, SBS-AA
SBS-AA
-150.0
R-68.
Existing asphalt BUR or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
R-69.
Existing asphalt BUR or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
R-70.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
R-71.
Existing smooth- or granulesurface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
R-72.
R-73.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
OB500
Min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 71 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-77.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2Part
BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
R-78.
Existing asphaltic roof cover
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
BP-AA or SBS-AA
(Optional) BPAA, SBS-AA, SBSTA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
R-79.
Existing asphaltic roof cover
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
SBS-TA or APPTA
(Optional) BPAA, SBS-AA, SBSTA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-232.5
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck or Dens Deck
Prime
GAF 2Part
BP-AA, SBS-AA,
SBS-TA or APPTA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
R-80.
SELF-ADHERING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER
R-81.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-127.5
R-82.
Existing granule surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-172.5
R-83.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-240.0
R-84.
Existing smooth surfaced BUR /
APP modified bitumen or
granule surface roof cover over
structural concrete deck
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-97.5
R-85.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck, Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500
SBS-SA
(Optional) SBSSA
SBS-TA or
APP-TA
-120.0
R-86.
Existing asphalt BUR or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-120.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 72 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-87.
Existing smooth- or granulesurface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-127.5
R-88.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-150.0
R-89.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
SBS-SA
(Optional) SBSSA
SBS-SA
-152.5
R-90.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck; surface shall be
primed with ASTM D41 primer
OB500
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-165.0
R-91.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-165.0
R-92.
Existing smooth- or granulesurface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch SECUROCK Gypsum Fiber
Roof Board
OB500
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-225.0
R-93.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA or
EnergyGuard RN
OB500,
6-inch
o.c.
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board (primer optional)
OB500,
6-inch
o.c.
SBS-SA
(Optional) SBSTA, APP-TA
SBS-TA,
APP-TA
-240.0
R-94.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA or
EnergyGuard RN
OB500,
6-inch
o.c.
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
6-inch
o.c.
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-240.0
R-95.
Existing smooth-surface BUR
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M,
M-OSFA
Min. 0.25-inch Dens Deck Prime
LRF-M,
M-OSFA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-75.0
R-96.
Existing smooth-surface BUR
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M,
M-OSFA
Min. 0.25-inch SECUROCK Gypsum Fiber
Roof Board
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-75.0
R-97.
Existing smooth surfaced BUR or
granule surface roof cover
Min. 1.5-inch EnergyGuard RH
LRF-M,
M-OSFA
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-75.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 73 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Top Insulation Layer
Type
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-98.
Existing granule-surface BUR or
modified bitumen or smoothsurface SBS modified bitumen
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M,
M-OSFA
Min. 0.25-inch Dens Deck Prime
LRF-M,
M-OSFA
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-127.5
R-99.
Existing granule-surface BUR or
modified bitumen or smoothsurface SBS modified bitumen
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M,
M-OSFA
Min. 0.25-inch SECUROCK Gypsum Fiber
Roof Board
LRF-M,
M-OSFA
SBS-SA or
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-225.0
R-100.
Existing asphaltic roof cover
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
GAF 2Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
GAF 2Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-232.5
R-101.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Min. 0.25-inch Dens Deck Prime
GAF 2Part
WeatherWatch
XT Mat Surfaced
Leak Barrier
(Optional) SBSTA or APP-TA
SBS-TA or
APP-TA
-240.0
VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
R-102.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-90.0
R-103.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
HA
B-LL
One or more BPAA, SBS-AA
SBS-TA or
APP-TA
-90.0
R-104.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
HA
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-90.0
R-105.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
HA
B-LL
One or more BPAA, SBS-AA
SBS-TA or
APP-TA
-90.0
R-106.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
(Optional) EnergyGuard
HA
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-150.0
R-107.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
(Optional) EnergyGuard
HA
B-LL
One or more BPAA, SBS-AA
SBS-TA or
APP-TA
-150.0
R-108.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard Ultra
HA
(Optional) EnergyGuard Ultra
HA
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-172.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 74 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-109.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard Ultra
HA
(Optional) EnergyGuard Ultra
HA
B-LL
One or more BPAA, SBS-AA
SBS-TA or
APP-TA
-172.5
R-110.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck or Dens Deck
Prime
HA
B-LL
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA
-240.0
R-111.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
or EnergyGuard Ultra
HA
Min. 0.25-inch Dens Deck or Dens Deck
Prime
HA
B-LL
One or more BPAA, SBS-AA
SBS-TA or
APP-TA
-240.0
COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
R-112.
Existing asphalt BUR
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
SBS-CA-1
None
SBS-CA-1
-120.0
R-113.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
SBS-CA-1
None
SBS-CA-1
-127.5
R-114.
Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500
SBS-CA
None
SBS-CA
-45.0
R-115.
Existing smooth surfaced BUR /
APP modified bitumen or
granule surface roof cover over
structural concrete deck
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
OB500
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-97.5
R-116.
Existing asphalt BUR
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-120.0
R-117.
Existing smooth APP or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
SBS-CA-1
None
SBS-CA-1
-127.5
R-118.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-165.0
R-119.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
SBS-CA-1
None
SBS-CA-1
-172.5
R-120.
Existing smooth surfaced BUR or
granule surface roof cover
Min. 1.5-inch EnergyGuard RH
LRF-M,
M-OSFA
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso
Insulation
LRF-M,
M-OSFA
SBS-CA or SBSCA-1
None
SBS-CA or
SBS-CA-1
-75.0
HYBRID HOT/COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 75 of 76
TABLE 7A-2: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 11)
Type
Top Insulation Layer
Attach
Type
Roof Cover
Attach
Base
Ply
Cap
MDP
(psf)
R-121.
Existing asphalt BUR
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
BP-AA or SBS-AA
(Optional) BP-AA
or SBS-AA
SBS-CA-1
-120.0
R-122.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
HA
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
HA
BP-AA or SBS-AA
(Optional) BP-AA
or SBS-AA
SBS-CA-1
-127.5
R-123.
Existing asphalt BUR
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA
or SBS-AA
SBS-CA-1
-120.0
R-124.
Existing smooth APP or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
BP-AA or SBS-AA
(Optional) BP-AA
or SBS-AA
SBS-CA-1
-127.5
R-125.
Existing smooth APP
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA
or SBS-AA
SBS-CA-1
-165.0
R-126.
Existing mineral surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board
OB500
BP-AA or SBS-AA
(Optional) BP-AA
or SBS-AA
SBS-CA-1
-172.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.11.04-R15 for FL5680-R15
Revision 15: 04/06/2015
Appendix 1, Page 76 of 76
Download