Florida Building Code Online BCIS Home Log In User Registration Page 1 of 2 Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL5680-R15 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (973) 872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley (current) Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert J.M. Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/06/2017 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL5680_R15_COI_2015_01_COI_Nieminen.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D6162 2000 ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2008 FM 4470 1992 FM 4474 2004 TAS 114 2011 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt45H1a2AP3I... 11/19/2015 Florida Building Code Online Product Approval Method Page 2 of 2 Method 1 Option D Date Submitted 04/06/2015 Date Validated 04/08/2015 Date Pending FBC Approval 04/12/2015 Date Approved 06/23/2015 Summary of Products FL # Model, Number or Name 5680.1 GAF Modified Bitumen Roof Systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-465 Other: 1.) The DP noted herein pertains to one specific system. Refer to the ER Appendix for all systems and max. design pressures. 2.) Refer to ER Section 5 for Limits of Use. Back Description SBS and APP Modified Bitumen Roof Systems Installation Instructions FL5680_R15_II_2015_04_FINAL_A1_ER_GAF_MB_FL5680-R15.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL5680_R15_AE_2015_04_FINAL_ER_GAF_MB_FL5680-R15.pdf Created by Independent Third Party: Yes Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt45H1a2AP3I... 11/19/2015 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street, Unit 13 Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF 1 Campus Drive Parsippany, NJ 07054 Evaluation Report 01506.11.05-R15 FL5680-R15 Date of Issuance: 11/07/2005 Revision 15: 04/06/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “TRINITY|ERD Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 76-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facimilie seal appearing was authorized by Robert Nieminen, P.E. on 04/06/2015. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: Modified Bitumen Roof Systems, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. 3. STANDARDS: Section Property Standard Year 1504.3.1 1515.1.1 1504.7 1507.11.2 1507.11.2 1507.11.2 1507.11.2 Wind Wind Impact Physicals Physicals Physicals Physicals FM 4474 TAS 114 FM 4470 ASTM D6162 ASTM D6163 ASTM D6164 ASTM D6222 2004 2011 1992 2000 2000 2005 2008 Entity Examination Reference Date ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) Florida TEC (TST7393) Florida TEC (TST7393) TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114/FM4474 TAS 114/FM4474 TAS 114/FM4474 TAS 114/FM4474 Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties TAS 114/FM4474 Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties TAS 114 TAS 114 ACRC 06-041 ACRC 06-042 ACRC 06-043 ACRC 006-044 ACRC 06-048 ACRC 06-049 ACRC 06-050 ACRC 07-006 ACRC 07-018 ACRC 07-028 ACRC 07-030 ACRC 07-032 ACRC 07-033 ACRC 07-041 ACRC 07-044 ACRC 07-047 ACRC 07-081 ACRC 07-082 ACRC 08-024 ACRC 08-034 ACRC 08-044 ACRC 11-043 ACRC 11-046 ACRC 11-048 ACRC 11-049 ACRC 11-050 ACRC 11-051 ACRC 11-052 ACRC 11-053 ACRC 11-054 ACRC 12-015 ACRC 12-026 ACRC 12-034 ACRC 12-035 01880.09.03 01516.04.06 4482.10.97-1 G4280LAB.10.06-R1 G6850.08.08 G6850.08.08-1 G6850.10.08 G6850.11.08 G12210.06.09 G12210.01.10 G31360.03.10 G33470.01.11 G36780.07.11-R1 G40620.07.12-2 G43190.11.13-1 G40630.01.14-1 G40630.01.14-2A G40630.01.14-2A-1 G40630.01.14-2B G40630.01.14-2C G43180.01.14-1 08-050187 08-050188 11/10/2006 11/14/2006 11/16/2006 11/16/2006 12/21/2006 12/22/2006 12/28/2006 01/17/2007 04/20/2007 05/08/2007 05/09/2007 05/10/2007 05/10/2007 08/31/2007 09/05/2007 09/07/2007 01/10/2008 01/11/2008 04/18/2008 05/19/2008 07/01/2008 08/08/2011 08/09/2011 08/10/2011 08/10/2011 08/11/2011 08/11/2011 08/12/2011 08/17/2011 08/17/2011 04/24/2012 05/10/2012 08/10/2012 08/13/2012 09/10/2003 04/20/2006 12/02/2006 12/06/2007 08/01/2008 08/29/2008 10/06/2008 11/05/2008 08/03/2009 01/08/2010 03/31/2010 01/13/2011 07/18/2011 07/17/2012 11/15/2013 01/06/2014 01/07/2014 01/07/2014 01/07/2014 01/07/2014 01/10/2014 04/28/2008 04/28/2008 REFERENCES: Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.11.04-R15 FL5680-R15 Revision 15: 04/06/2015 Page 2 of 6 Entity Examination Reference Date Florida TEC (TST7393) Florida TEC (TST7393) Florida TEC (TST7393) Florida TEC (TST7393) Florida TEC (TST7393) Florida TEC (TST7393) Florida TEC (TST7393) Florida TEC (TST7393) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 08-070077 08-070084 08-050181R 08-050186 08-070126 08-070122 08-070127 08-080077 1B9A8.AM 3007500 3005640 3008178 3010215 3009788 3011140 3013614 3013788 3014547 3014692 3014960 3017250 3022139 3022508 3025023 797-02095-267 3023458 3028039 3024805 3032388 3032695 3032943 3032811 3033719 3035864 3032172 3035140 3036225 3034978 797-05447-267 797-05487-267 797-05550-267 797-05538-267 797-05594-267 797-05695-267 797-05683-267 797-05687-267 797-05748-267 3040738 3036960 797-06129-267 797-06177-267 797-06540-267 797-06800-267 797-07038-267 797-07073-267 3038128 3040738 3041535 3044688 797-07198-267 3044688 (Re-Issue) 3044541 3044862 3043900 3046280 3046388 3041769 3046403 3046054 3046081 797-08216-267 3048122 3047104 797-08263-267 797-08264-267 3047237 797-08670-267 797-08873-267 3048871 3048066 797-09016-267 3048496 3049601 797-09984-267 07/25/2008 07/25/2008 04/01/2009 10/14/2008 10/14/2008 10/14/2008 10/14/2008 11/17/2008 09/04/1997 06/15/2000 11/09/2000 12/27/2000 03/01/2001 03/28/2001 08/14/2001 05/06/2002 01/10/2003 05/22/2003 08/05/2003 03/05/2004 04/05/2004 05/26/2005 07/20/2005 12/14/2005 04/26/2006 07/18/2006 09/11/2006 11/20/2006 10/30/2008 10/30/2008 11/06/2008 12/11/2008 01/16/2009 06/03/2009 06/12/2009 08/10/2009 08/10/2009 09/17/2009 04/13/2010 05/12/2010 05/25/2010 05/25/2010 06/01/2010 07/15/2010 07/21/2010 07/21/2010 08/10/2010 11/16/2010 11/30/2010 01/13/2011 03/16/2011 06/21/2011 09/29/2011 01/10/2012 01/19/2012 07/26/2010 11/16/2010 06/08/2011 03/01/2012 03/01/2012 03/16/2012 04/04/2012 05/11/2012 08/16/2012 08/22/2012 09/24/2012 09/27/2012 09/28/2012 12/21/2012 02/13/2013 04/11/2013 04/29/2013 05/10/2013 05/23/2013 05/23/2013 07/15/2013 09/16/2013 11/26/2013 12/11/2013 12/13/2013 12/17/2013 12/19/2013 01/29/2014 10/28/2014 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.11.04-R15 FL5680-R15 Revision 15: 04/06/2015 Page 3 of 6 4. Entity Examination Reference Date FM Approvals (TST1867) FM Approvals (TST1867) IRT (TST7408) IRT (TST7408) IRT (TST7408) IRT (TST7408) IRT (TST7408) IRT (TST7408) IRT (TST7408) IRT (TST7408) Miami-Dade (CER1592) MTI (TST2508) MTI (TST2508) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) UL, LLC (QUA9625) FM 4470/4474 FM 4470/4474 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 Various Physical Properties Physical Properties Physical Properties FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Quality Assurance 797-09987-267 797-10017-267 00001 00002 01-039 02-005 02-014 03-003 03-004 04-008 Current NOAs AX04C9A RX30C9C GAF-027-02-01 GAF-434-02-01 GAF-434-02-03 GAF-434-02-04 GAF-436-02-02 GAF-436-02-03 GAF-436-02-04 GAF-436-02-05 GAF-436-02-08 GAF-436-02-09 GAF-549-02-01 GAF-549-02-02 GAF-559-02-01 GAF-559-02-04 GAF-559-02-05 GAF-559-02-06 GAF-559-02-07 GAF-559-02-08 GAF-559-02-09 GAF-559-02-11 GAF-559-02-12 GAF-559-02-13 GAF-559-02-14 GAF-559-02-15 GAF-559-02-16 GAF-559-02-17 GAF-559-02-18 Inspection Report, R1306 10/28/2014 11/06/2014 03/30/2000 03/30/2000 01/24/2002 01/24/2002 03/26/2002 04/21/2003 04/21/2003 01/26/2004 Current 06/05/2009 07/09/2009 03/26/2002 09/16/2013 09/16/2013 09/16/2013 03/06/2014 03/06/2014 03/06/2014 03/06/2014 03/06/2014 03/06/2014 08/08/2014 08/08/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 10/16/2014 01/06/2015 PRODUCT DESCRIPTION: This Evaluation Report covers GAF Modified Bitumen Roof Systems installed in accordance with GAF published installation instructions and the Limitations / Conditions of Use herein. The following products make up the subject systems. TABLE 1: ROLL-GOODS FOR GAF MODIFIED BITUMEN ROOF SYSTEMS Type Base Sheet Product Type Grade GAFGLAS® #75 Base Sheet ASTM D4601 II N/A Tri-Ply® #75 Base Sheet ASTM D4601 II N/A GAFGLAS® #80 Ultima™ Base Sheet ASTM D4601 II N/A StormSafe™ Anchor Sheet Proprietary N/A N/A ASTM D4897 II N/A ASTM D4897 II N/A N/A N/A GAFGLAS® Stratavent® Nailable Venting Base Sheet (formerly GAFGLAS® Stratavent® Eliminator™ Nailable Venting Base Sheet) GAFGLAS® Stratavent® Perforated Venting Base Sheet (formerly GAFGLAS® Stratavent® Eliminator™ Perforated Venting Base Sheet) Liberty™ SBS Mechanically Attached Base Sheet (formerly Liberty™ MA Mechanically-Attached Base Sheet) Ply Sheet Specification Reference Proprietary GAFGLAS® Ply 4 ASTM D2178 IV N/A Tri-Ply® Ply 4 ASTM D2178 IV N/A GAFGLAS® FlexPly™ 6 ASTM D2178 VI N/A Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.11.04-R15 FL5680-R15 Revision 15: 04/06/2015 Page 4 of 6 TABLE 1 (CONTINUED): ROLL-GOODS FOR GAF MODIFIED BITUMEN ROOF SYSTEMS Type Smooth Surfaced Membranes: Type Grade Liberty™ SBS Self-Adhering Base/Ply Sheet ASTM D1970 N/A N/A UnderRoof™ 2 Polyester-Surfaced Leak Barrier ASTM D1970 N/A N/A UnderRoof™ HT High Temperature Leak Barrier ASTM D1970 N/A N/A WeatherWatch® XT Mat Surfaced Leak Barrier ASTM D1970 N/A N/A Ruberoid® 20 Smooth (formerly Ruberoid® 20) ASTM D6163 I S Ruberoid® HW 25 Smooth (formerly Ruberoid® SBS Heat-Weld 25) ASTM D6163 I S Ruberoid® HW Smooth (formerly Ruberoid® SBS Heat-Weld Smooth) ASTM D6164 I S Ruberoid® Mop Smooth ASTM D6164 I S Ruberoid® Mop Smooth 1.5 ASTM D6164 I S Ruberoid® Mop Plus Smooth ASTM D6164 II S Ruberoid® Torch Smooth ASTM D6222 I S Tri-Ply® APP Smooth (formerly Tri-Ply® TP-4) ASTM D6222 I S Ruberoid® 30 Granule (formerly Ruberoid® 30) ASTM D6163 I G Ruberoid® 30 Granule FR (formerly Ruberoid® 30 FR) ASTM D6163 I G ASTM D6163 I G Liberty™ SBS Self-Adhering Cap Sheet ASTM D6164 I G Ruberoid® Mop Granule FR (formerly Ruberoid® Mop 170 FR) ASTM D6164 I G Ruberoid® Mop Granule ASTM D6164 I G Intec Flex PRF ASTM D6164 I G Tri-Ply® SBS Granule (formerly Tri-Ply® SBS Modified Bitumen Membrane) ASTM D6164 I G Ruberoid® HW Granule (formerly Ruberoid® SBS Heat-Weld Granule) ASTM D6164 I G Ruberoid® HW Granule FR (formerly Ruberoid® SBS Heat-Weld 170 FR) ASTM D6164 I G Ruberoid® Mop Plus Granule FR (formerly Ruberoid® Mop FR) ASTM D6164 II G Ruberoid® Mop Plus Granule (formerly Ruberoid® Mop Plus) ASTM D6164 II G ASTM D6164 II G Ruberoid® HW Plus Granule (formerly Ruberoid® SBS Heat-Weld Plus) ASTM D6164 II G Ruberoid® HW Plus Granule FR (formerly Ruberoid® SBS Heat-Weld Plus FR) ASTM D6164 II G ASTM D6164 II G Ruberoid® Torch Granule ASTM D6222 I G Tri-Ply® APP Granule (formerly Tri-Ply® TP-4G) ASTM D6222 I G Ruberoid® Torch Plus Granule FR (formerly Ruberoid® Torch FR) ASTM D6222 II G Ruberoid® EnergyCap™ Torch Granule FR ASTM D6222 I G ASTM D6222 II G Ruberoid® EnergyCap™ 30 Granule FR (formerly Ruberoid® EnergyCap™ 30 FR SBS Membrane) Granule Surfaced Membranes: Ruberoid® EnergyCap™ Mop Plus Granule FR (formerly Ruberoid® EnergyCap™ Mop FR) Ruberoid® EnergyCap™ HW Plus Granule FR (formerly Ruberoid® EnergyCap™ SBS Heat-Weld Plus FR) Ruberoid® EnergyCap™ Torch Plus Granule FR (formerly Ruberoid® EnergyCap™ Torch Plus FR) 5. Specification Product Reference LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.11.04-R15 FL5680-R15 Revision 15: 04/06/2015 Page 5 of 6 6. 7. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.8 For fully-adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. INSTALLATION: 6.1 GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF’s published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC – QUA9625; (847) 664-3281 - THE 76-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.11.04-R15 FL5680-R15 Revision 15: 04/06/2015 Page 6 of 6 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description 1A Wood New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 1B-1 Wood New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-8 1B-2 Wood New, Reroof (Tear-Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 9-11 1C Wood New, Reroof (Tear-Off), Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 1D Wood New, Reroof (Tear-Off), Recover C Mech. Attached Insulation, Bonded Roof Cover 12 1E Wood New, Reroof (Tear-Off), Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 1F-1 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-14 1F-2 Wood New, Reroof (Tear-Off), Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 15 2A-1 Steel or Conc. New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 2A-2 Steel or Conc. New, Reroof (Tear-Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 2B-1A Steel or Conc. New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 2B-1B Steel or Conc. New, Reroof (Tear-Off), Recover C-1A Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover 2B-2 Steel or Conc. New, Reroof (Tear-Off), Recover C-2 Bonded and Mech. Attached Insulation, Bonded Roof Cover 2C Steel or Conc. New, Reroof (Tear-Off), Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 34-37 3A-1 Concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 38-40 3A-2 Concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 41-49 3A-3 Concrete New, Reroof (Tear-Off) A-1a Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 50-52 3B Concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 4A LWIC New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 4B LWIC New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4C LWIC New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 4D LWIC New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 59 5A CWF New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 60 5B CWF New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 61 5C CWF New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 62 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 63 6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 6C Gypsum Reroof (Tear-Off) C Mech. Attached Insulation, Bonded Roof Cover 6D Gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 64-65 7A-1 Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 66-69 7A-2 Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 70-76 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Page 4 13 16-22 23 24-32 33 33 53 54-55 56 57-59 64 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 1 of 76 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: Wood: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. Steel: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener - Insulation. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. Concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate. Minimum 1-inch embedment into pilot hole in accordance with the fastener manufacturer’s published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. VersaShield® Solo™ Fire-Resistant Slip Sheet may be used as a non-load-bearing, fire-barrier slip-sheet component within any system outlined herein. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. Hot asphalt (HA): Full coverage at 25-30 lbs/square OMG OlyBond 500 (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used where OlyBond 500 is referenced. GAF LRF Adhesive M (LRF-M): Continuous 1-inch wide ribbons, 12-inch o.c ADCO Millennium One-Step Foamable Adhesive (M-OSFA): Continuous 1-inch wide ribbons, 12-inch o.c. GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Note: 3M CR-20 may be used where GAF 2-Part is referenced. Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. Hot asphalt (HA): MDP -240.0 psf (Min. 0.5-inch thick) OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN) OMG OlyBond 500 (OB500): MDP -485.0 psf (Min. 0.5-inch thick EnergyGuard RA) GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 2 of 76 11. For existing substrates in a bonded recover installation, the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or ANSI/SPRI IA-1. 12. For Recover Applications using System Type D, the insulation is optional. Alternatively, min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, Structodek High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board may be used as a separator board prior to base sheet installation. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover in Recover applications. 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Reference Layer Material Base: BP-AA (Base/ Ply sheets, Asphalt-Applied) Ply: Application GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet Hot asphalt at 25 lbs/square. One or more plies GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6 BP-CA (Base/ Ply sheets, Cold-Applied) Base: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Matrix™ 102 SBS Membrane Adhesive (formerly known as TOPCOAT MATRIX 102 SBS Membrane Adhesive) at 1.5 gal/sq. B-LL (Base sheet, Loose-Laid) Base: GAFGLAS Stratavent Perforated Venting Base Sheet Loose laid Base or Ply: SBS-AA (SBS, Asphalt-Applied) SBS-CA (SBS, Cold-Applied, Matrix™ 102 SBS Membrane Adhesive) Cap: Base or Ply: Cap: Base: SBS-CA-1 (SBS, Cold-Applied, Matrix™ 101 Premium SBS Membrane Adhesive) SBS-TA (SBS, Torch-Applied) APP-TA (APP, Torch-Applied) SBS-SA (self-adhering) Cap: Base or Ply: Cap: Base or Ply: Cap: Base or Ply: Cap One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule, Intec Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus Granule FR Hot asphalt at 25 lbs/square. Ruberoid 20 Smooth Matrix™ 102 SBS Membrane Adhesive (formerly known as TOPCOAT MATRIX 102 SBS Membrane Adhesive) at 1.5 gal/sq. Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR Matrix™ 101 Premium SBS Membrane Adhesive (formerly known as TOPCOAT MATRIX Majorbond Modified Bitumen Membrane Adhesive) at 1.5 – 2.0 gal/square One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth Torch applied Ruberoid Torch Granule, Tri-Ply APP Granule, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch Granule FR, Ruberoid EnergyCap Torch Plus Granule FR Liberty SBS Self-Adhering Base/Ply Sheet Self-adhered Liberty SBS Self-Adhering Cap Sheet 14. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 3 of 76 TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Attach Type GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 GAF 2-Part BP-AA, SBS-AA, SBSTA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 GAF 2-Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -52.5 W-1. Min. 19/32-inch plywood or OSB at max. 24-inch span Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN W-2. Min. 19/32-inch plywood or OSB at max. 24-inch span Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board W-3. Min. 19/32-inch plywood or OSB at max. 24-inch span Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Roof Cover Attach Base Ply Cap MDP (psf) Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 4 of 76 TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Anchor Sheet Deck (See Note 1) Type Base Insulation Fasteners Attach Type Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN Top Insulation Attach Type Roof Cover Attach MDP (psf) Base Ply Cap HA BP-AA, SBSAA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 HA BP-AA, SBSAA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 HA BP-AA, SBSAA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 HA BP-AA, SBSAA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 CONVENTIONAL SYSTEMS: W-4. W-5. W-6. W-7. Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 5 of 76 TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. W-8. W-9. W-10. W-11. Anchor Sheet Deck (See Note 1) Type Fasteners Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch diameter tin caps with 12 ga. annular ring shank nails Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch diameter tin caps with 12 ga. annular ring shank nails Min. 19/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch diameter tin caps with 12 ga. annular ring shank nails GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch diameter tin caps with 12 ga. annular ring shank nails Min. 19/32inch plywood at max. 24inch span Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Base Insulation Attach Type 6-inch o.c. at the 4-inch lap and 6inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN 6-inch o.c. at the 4-inch lap and 6inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN 8-inch o.c. at the 4-inch lap and 8inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN 8-inch o.c. at the 4-inch lap and 8inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN Top Insulation Attach Type HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board Roof Cover Attach MDP (psf) Base Ply Cap HA BP-AA, SBSAA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 HA BP-AA, SBSAA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 HA BP-AA, SBSAA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 HA BP-AA, SBSAA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 6 of 76 TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. W-12. W-13. Anchor Sheet Deck (See Note 1) Base Insulation Type Fasteners Attach Type Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Top Insulation Attach Type Roof Cover Attach MDP (psf) Base Ply Cap HA BP-AA, SBSAA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 HA BP-AA, SBSAA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 SBS-SA, SBS-TA or APPTA -45.0 SBS-TA, APP-TA -45.0 HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA SBS-SA (Optional) SBS-SA, SBS-TA or APP-TA Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5inch EnergyGuard RA or EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA Weather Watch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SELF-ADHERING SYSTEMS: W-14. W-15. Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 VENTING SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 7 of 76 TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Anchor Sheet Deck Base Insulation Top Insulation Roof Cover MDP (psf) (See Note 1) Type Fasteners Attach Type W-16. Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation HA B-LL (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-17. Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation HA B-LL (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-18. Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation HA B-LL (Optional) BP-AA, SBS-AA SBS-AA -52.5 W-19. Min. 19/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 15/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation HA B-LL (Optional) BP-AA, SBS-AA SBS-AA -52.5 W-20. Min. 19/32inch plywood at max. 24inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 15/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation HA B-LL (Optional) BP-AA, SBS-AA SBS-AA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Attach Type Attach Base Ply Cap Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 8 of 76 TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Anchor Sheet Type Fasteners Base Insulation Attach Type See Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN Top Insulation Attach Type Roof Cover Attach Base MDP (psf) Ply Cap SBS-AA, SBS-TA, APP-TA -45.0 CONVENTIONAL SYSTEMS: W-21. W-22. W-23. W-24. Min. 19/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 19/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 HA BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 9 of 76 TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. W-25. W-26. W-27. W-28. Deck (See Note 1) Anchor Sheet Type Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 19/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 19/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Fasteners Base Insulation Attach Type See Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN Top Insulation Attach Type HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board Roof Cover Attach Base MDP (psf) Ply Cap SBS-AA, SBS-TA, APP-TA -60.0 HA BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 HA BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 10 of 76 TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Anchor Sheet Type Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth W-31. Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth W-32. Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth W-33. Min. 15/32inch plywood at max. 24inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth W-29. W-30. Fasteners Base Insulation Attach Type Attach Type HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA (Optional) Additional layer(s) base insulation Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso HA (Optional) Additional layer(s) base insulation 8-inch o.c. at the 4-inch lap and 8inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5-inch EnergyGuard RA or EnergyGuard RN See Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso See Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows See Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8inch o.c. in three staggered center rows See Note 2 (#14 ONLY) Top Insulation Roof Cover Attach Base MDP (psf) Ply Cap SBS-AA, SBS-TA, APP-TA -75.0* HA BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 B-LL One or more BPAA, SBSAA SBS-AA, SBS-TA, APP-TA -52.5 HA B-LL One or more BPAA, SBSAA SBS-AA, SBS-TA, APP-TA -60.0 HA B-LL One or more BPAA, SBSAA SBS-AA, SBS-TA, APP-TA -82.5* VENTING SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 HA Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 11 of 76 TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover Deck (See Note 1) Type Fasteners Attach W-34. Min. 19/32-inch plywood at max. 24-inch span Min. 1-inch EnergyGuard RN Drill-Tec #12 Fastener with Drill-Tec AccuTrac Flat Plate or AccuTrac Recessed Plate 1 per 1.78 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 W-35. Min. 19/32-inch plywood at max. 24-inch span Min. 1-inch EnergyGuard RN Drill-Tec #12 Fastener with Drill-Tec AccuTrac Flat Plate or AccuTrac Recessed Plate 1 per 1.78 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 System No. Type Attach Base Ply Cap MDP (psf) TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Roof Cover Fasteners Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: W-36. Min. 19/32-inch plywood at max. 24-inch span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Composite or EnergyGuard RA Composite See Note 2 1 per 3 ft2 BP-AA, SBSAA (Optional) BPAA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-37. Min. 19/32-inch plywood at max. 24-inch span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75inch EnergyGuard Perlite Roof Insulation (homogeneous) See Note 2 1 per 2 ft2 BP-AA, SBSAA (Optional) BPAA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-38. Min. 19/32-inch plywood at max. 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board See Note 2 (#14 only) 1 per 1.78 ft2 BP-AA, SBSAA, SBS-TA, APP-TA (Optional) BPAA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 (HD Fasteners only) 1 per 2 ft2 SBS-SA (Optional) SBSSA SBS-SA -45.0 SELF-ADHERING SYSTEMS: W-39. Min. 15/32-inch plywood at max. 24-inch span Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 12 of 76 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Insulation Layer(s) Type Base or Anchor Sheet Attach Base Fasteners Roof Cover Cap MDP (psf) Attach Ply See Note 2 12-inch o.c. at min. 2-inch laps and 12inch o.c. in two, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 See Note 2 12-inch o.c. at min. 2-inch laps and 12inch o.c. in three, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 See Note 2 8-inch o.c. at min. 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -75.0 CONVENTIONAL SYSTEMS: W-40. Min. 19/32-inch plywood at max. 24-inch span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth W-41. Min. 19/32-inch plywood at max. 24-inch span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth W-42. Min. 19/32-inch plywood at max. 24-inch span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth TABLE 1F-1: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Base Sheet Deck (See Note 1) Type Roof Cover Faster Attachment Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: W-43. Min. 15/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -45.0 W-44. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -45.0 W-45. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-46. Min. 15/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 13 of 76 TABLE 1F-1: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Base Sheet Deck (See Note 1) Type Roof Cover Faster Attachment Ply Cap MDP (psf) W-47. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -52.5 W-48. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0 W-49. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. at three, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -75.0 W-50. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -82.5 SELF-ADHERING SYSTEMS: W-51. Min. 19/32-inch plywood at max. 24-inch span Liberty SBS Mechanically Attached Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, SBS-TA or APP-TA -37.5 W-52. Min. 15/32-inch plywood at max. 24-inch span Liberty SBS Mechanically Attached Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 3-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, SBS-TA or APP-TA -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 14 of 76 TABLE 1F-2: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Base Sheet Deck (See Note 1) Type Roof Cover Faster Attachment Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: W-53. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth See Note 2 12-inch o.c. at 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-54. Min. 15/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth See Note 2 (#14 ONLY) 16-inch o.c. at 4-inch laps and 16-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -52.5 W-55. Min. 15/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth See Note 2 (#14 ONLY) 12-inch o.c. at 4-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -60.0 W-56. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth See Note 2 12-inch o.c. at 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-57. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #80 Ultima Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 See Note 2 9-inch o.c. at 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA (polyester only) -60.0 W-58. Min. 15/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth See Note 2 (#14 ONLY) 8-inch o.c. at 4-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA -97.5 W-59. Min. 19/32-inch plywood at max. 24-inch span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth See Note 2 8-inch o.c. at 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA, SBS-TA, SBS-CA, APP-TA -105.0 W-60. Min. 19/32-inch plywood at max. 24-inch span StormSafe Anchor Sheet See Note 2 (DrillTec AccuTrac Flat Plate only) 9-inch o.c. at 4-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA Note: Seams sealed with TOPCOAT SB900 or Flexseal W-61. Min. 15/32-inch plywood at max. 24-inch span Liberty SBS Mechanically Attached Base Sheet See Note 2 (HD Fasteners only) 8-inch o.c. at 3-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, SBS-TA or APP-TA SELF-ADHERING SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 SBS-SA -60.0 -60.0 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 15 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: SC-1 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -37.5* SC-2 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 Min. 1.5-inch EneryGuard followed by min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA APP-TA (Optional) APPTA APP-TA -45.0* SC-3 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 0.5-inch Dens Deck Prime See Note 2 1 per 2.67 ft2 Min. 1.5-inch EneryGuard followed by min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA APP-TA (Optional) APPTA APP-TA -45.0* SC-4 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.67 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-5 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-6 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum Fiber Roof Board HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-7 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-8 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-9 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 16 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Roof Cover Attach Base Ply Cap MDP (psf) SC-10 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2.2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-11 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.45 ft2 Min. 1.0-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA or SBS-TA -60.0 HA BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-12 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.33 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board SC-13 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.45 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA or SBS-TA -67.5 SC-14 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers of base insulation; Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA, GAF 2-Part, OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-15 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Optional additional layers of base insulation; Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA, GAF 2-Part, OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-16 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 2 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA, GAF 2-Part or OB500 BP-AA, SBS-AA None SBS-CA -45.0* SC-17 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board HA, GAF 2-Part, OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 17 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. SC-18 Deck (See Note 1) Min. 22 ga., type B, Grade 33 steel or structural concrete Base Insulation Layer Top Insulation Layer Type Roof Cover Type Fasten Attach Attach Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, OB500 or GAF 2-Part Min. 1.5-EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation 1 per 2.9 ft2 Base MDP (psf) Ply Cap BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 OB500, LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -37.5* Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -37.5* SELF-ADHERING SYSTEMS: SC-19 Min. 22 ga., Type B, Grade 33 steel or structural concrete SC-20 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 2-EnergyGuard RH See Note 2 SC-21 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-22 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-23 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layer(s), min. 1.5-inch thick base insulation OB500, LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-24 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers of base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-25 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch thick base insulation; Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M-OSFA SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 18 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Roof Cover Attach Base Ply Cap MDP (psf) SC-26 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1-nich thick base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M-OSFA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-27 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation; Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M-OSFA SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-28 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M-OSFA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-29 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBSSA SBS-SA -45.0* SC-30 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Optional additional layers of base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-31 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation; Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M-OSFA SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-32 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M-OSFA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-33 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-34 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-35 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, GAF 2-Part SBS-SA (Optional) SBSSA SBS-SA -45.0* SC-36 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers of base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA, GAF 2-Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 19 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Fasten Attach Type Roof Cover Attach Base Ply Cap MDP (psf) SC-37 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Optional additional layers of base insulation; Min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA, GAF 2-Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-38 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board HA, GAF 2-Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-39 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA, GAF 2-Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layer of base insulation Hot asphalt B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* VENTING SYSTEMS: SC-40 Min. 22 ga., type B, Grade 33 steel or structural concrete COLD-APPLIED SYSTEMS: SC-41 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 1.5-EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M-OSFA SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -37.5* SC-42 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 2-EnergyGuard RH See Note 2 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M-OSFA SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -37.5* SC-43 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -45.0* SC-44 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -45.0* HYBRID HOT/COLD-APPLIED SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 20 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Fasten Top Insulation Layer Roof Cover Attach Type Attach Base HA BP-AA or SBS-AA Cap MDP (psf) (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* Ply SC-45 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board SC-46 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.67 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* SC-47 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min.0.5-inch EnergyGuard Perlite Recover Board, min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* 1 per 4 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* HA BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* HA BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* SC-48 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 SC-49 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board SC-50 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 21 of 76 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Fasten Top Insulation Layer Roof Cover Attach Type HA BP-AA or SBS-AA See Note 2 1 per 1.33 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Attach Base Cap MDP (psf) (Optional) BPAA or SBS-AA SBS-CA-1 -60.0 Ply SC-51 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN SC-52 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* SC-53 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 22 of 76 TABLE 2A-2: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Thermal Barrier Type Fastener Attach Temp Roof Insulation Layer(s) Type Roof Cover Attach Base Ply Cap MDP (psf) SELF-ADHERING SYSTEMS: SC-54 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board SC-55 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board SC-56 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board SC-57 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board SC-58 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board SC-59 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA None SBS-SA -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA None SBS-SA -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBSCA-1 None SBS-CA or SBSCA-1 -45.0* See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) COLD-APPLIED SYSTEMS: SC-60 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 23 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Roof Cover Fasteners Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: SC-61 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 4 ft2 SBS-TA or APP-TA (Optional) SBSTA or APP-TA SBS-TA or APP-TA -30.0* SC-62 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBSTA or APP-TA SBS-TA or APP-TA -37.5* SC-63 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 SBS-TA or APP-TA (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* SC-64 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2.13 ft2 SBS-TA or APP-TA (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* SC-65 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* SC-66 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck, Dens Deck Prime See Note 2 1 per 4 ft2 BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA, SBS-TA, APP-TA -45.0* SC-67 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Fiber Base HD1 or Fiber Base HD6 See Note 2 1 per 2.9 ft2 SBS-AA (Optional) SBSAA SBS-AA, SBS-TA -45.0* SC-68 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Structodek High Density Fiberboard Roof Insulation See Note 2 1 per 2 ft2 SBS-AA (Optional) SBSAA SBS-AA, SBS-TA -45.0* SC-69 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BPAA, SBS-AA, SBS-TA or APPTA SBS-AA, SBS-TA or APP-TA -45.0* SC-70 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 4 ft2 BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBS-TA SBS-AA, SBS-TA -45.0* SC-71 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.6 ft2 SBS-AA, SBS-TA, APP-TA (Optional) SBSAA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 24 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Deck (See Note 1) Base Insulation Layer SC-72 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-73 Min. 22 ga., type B, Grade 33 steel or structural concrete System No. Top Insulation Layer Cap MDP (psf) Fasteners Attach Base Ply Min. 0.25-inch Dens Deck Prime See Note 2 1 per 1.45 ft2 SBS-AA, SBS-TA, APP-TA (Optional) SBSAA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.78 ft2 SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -52.5 SC-74 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (#14 only) 1 per 1.78 ft2 BP-AA, SBS-AA (Optional) BPAA, SBS-AA, SBS-TA or APPTA SBS-AA, SBS-TA or APP-TA -60.0 SC-75 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-76 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-77 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation See Note 2 1 per 1 ft2 SBS-AA (Optional) SBSAA or SBS-TA SBS-AA, SBS-TA -67.5 SC-78 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -67.5 SC-79 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBS-TA SBS-AA, SBS-TA -82.5 SC-80 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBS-TA SBS-AA, SBS-TA -90.0 SC-81 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1 ft2 SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -97.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Type Roof Cover Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 25 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Deck (See Note 1) Base Insulation Layer SC-82 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-83 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-84 System No. SC-85 Top Insulation Layer Type Roof Cover Base Ply Cap MDP (psf) Fasteners Attach Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.45 ft2 BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBS-TA SBS-AA, SBS-TA -97.5 (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime See Note 2 (#14 only) 1 per 1 ft2 SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -105.0 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (#14 only) 1 per 1 ft2 APP-TA (Optional) APPTA APP-TA -105.0 Min. 22 ga., type B, Grade 33 steel or structural concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (#14 only) 1 per 1 ft2 SBS-TA (Optional) SBSTA SBS-TA, APP-TA -120.0 SELF-ADHERING SYSTEMS: SC-86 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBSSA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -30.0* SC-87 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 3.2 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -30.0* SC-88 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 4 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -30.0* SC-89 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -37.5* SC-90 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 4 ft2 SBS-SA (Optional) SBSSA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -37.5* SC-91 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -37.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 26 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Deck (See Note 1) Base Insulation Layer SC-92 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-93 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-94 System No. Top Insulation Layer Base Ply Cap MDP (psf) Fasteners Attach Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBSSA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -45.0* (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2.7 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-95 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2.13 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* SC-96 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* SC-97 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -45.0* SC-98 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-99 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 2 ft2 SBS-SA (Optional) SBSSA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -45.0* SC-100 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-101 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* SC-102 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Type Roof Cover Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 27 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer SC-103 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-104 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-105 Top Insulation Layer Roof Cover Cap MDP (psf) (Optional) SBSSA SBS-SA -45.0* WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -52.5 1 per 1.6 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -52.5 See Note 2 1 per 1.78 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -52.5 Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 1.33 ft2 SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.33 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 1.45 ft2 SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-110 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.45 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-111 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 1.78 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -60.0 SC-112 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -60.0 SC-113 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (#14 only) 1 per 1.78 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -60.0 Fasteners Attach Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra See Note 2 1 per 2 ft2 SBS-SA (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime See Note 2 1 per 1.45 ft2 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 SC-106 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board SC-107 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-108 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-109 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Type Base Ply Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 28 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer SC-114 Min. 22 ga., Type B, Grade 33 steel or structural concrete SC-115 Top Insulation Layer Roof Cover Cap MDP (psf) Type Fasteners Attach Base Ply (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 1.33 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -67.5 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -67.5 SC-116 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -97.5 SC-117 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 (#14 only) 1 per 1 ft2 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -105.0 VENTING SYSTEMS: SC-118 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -37.5* SC-119 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-120 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-121 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RH See Note 2 1 per 2.9 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-122 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Ultra See Note 2 1 per 3.2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-123 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2.5-inch EnergyGuard RA See Note 2 1 per 4 ft2 B-LL BP-AA, SBS-AA SBS-AA -45.0* SC-124 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 29 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer SC-125 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-126 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-127 Top Insulation Layer Roof Cover Cap MDP (psf) (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* B-LL One or more BP-AA, SBS-AA SBS-AA -45.0* 1 per 2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 See Note 2 1 per 2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 Min. 2.0-inch EnergyGuard Ultra See Note 2 1 per 2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.45 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-132 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.6 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-133 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 1.45 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 SC-134 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra See Note 2 1 per 1.45 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 SC-135 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA (ASTM D6164, polyester only) -82.5 Fasteners Attach Min. 3-inch EnergyGuard Polyiso Insulation See Note 2 1 per 3.2 ft2 B-LL (Optional for recover) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 SC-128 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH SC-129 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-130 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-131 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Type Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH See Note 2 1 per 1.45 ft2 Base Ply Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 30 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer SC-136 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-137 Min. 22 ga., type B, Grade 33 steel or structural concrete SC-138 Min. 22 ga., type B, Grade 33 steel or structural concrete Top Insulation Layer Type Roof Cover Cap MDP (psf) (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 1 per 1 ft2 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -97.5 Fasteners Attach Base Min. 3-inch EnergyGuard Polyiso Insulation See Note 2 1 per 1.6 ft2 B-LL (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck See Note 2 1 per 1 ft2 (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 Ply COLD-APPLIED SYSTEMS: SC-139 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation See Note 2 1 per 2 ft2 BP-CA None SBS-CA -45.0* SC-140 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 4 ft2 SBS-CA None SBS-CA -45.0* SC-141 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RH or EnergyGuard RN See Note 2 1 per 2 ft2 SBS-CA-1 None SBS-CA-1 -45.0* SC-142 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH or EnergyGuard RN See Note 2 1 per 2.9 ft2 SBS-CA-1 None SBS-CA-1 -45.0* SC-143 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 SBS-CA-1 None SBS-CA-1 -45.0* SC-144 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, min. 1.5-inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 SBS-CA or SBS-CA-1 None SBS-CA or SBS-CA-1 -45.0* SC-145 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (AccuTrac Flat Plates only) 1 per 1.33 ft2 SBS-CA-1 None SBS-CA-1 -52.5 SC-146 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 1.33 ft2 SBS-CA-1 None SBS-CA-1 -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 31 of 76 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer SC-147 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid SC-148 Min. 22 ga., Type B, Grade 33 steel or structural concrete Top Insulation Layer Type Roof Cover Cap MDP (psf) None SBS-CA-1 -67.5 SBS-CA-1 None SBS-CA-1 -67.5 Fasteners Attach Base Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 1.78 ft2 SBS-CA-1 One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 Ply HYBRID HOT/COLD-APPLIED SYSTEMS: SC-149 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 4 ft2 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -45.0* SC-150 Min. 22 ga., Type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (AccuTrac Flat Plates) 1 per 1.33 ft2 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -52.5 SC-151 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -60.0 SC-152 Min. 22 ga., type B, Grade 33 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -82.5 SC-153 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -90.0 SC-154 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or structural concrete (Optional for recover) One or more layers, any combination, loose laid Min. 0.5-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.45 ft2 BP-AA or SBS-AA (Optional) BPAA or SBS-AA SBS-CA-1 -97.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 32 of 76 TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Top Insulation Layer Base Insulation Layer Type Roof Cover Fasten Attach Base Ply Cap MDP (psf) SELF-ADHERING SYSTEMS: SC-155 Min. 22 ga., Type B, Grade 33 steel or structural concrete Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 SBS-CA or SBS-CA-1 None SBS-CA or SBSCA-1 -45.0* COLD-APPLIED SYSTEMS: SC-156 Min. 22 ga., Type B, Grade 33 steel or structural concrete TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: BONDED AND MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Roof Cover Adhesive & Fasteners Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: SC-157 Min. 22 ga., type B, Grade 33 steel or structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, Loose-Laid Min. 0.25inch Dens Deck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill-Tec #14 HD (concrete ony) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.33 ft2 SBS-TA or APP-TA (Optional) SBSTA or APP-TA SBS-TA or APPTA -97.5 Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, Loose-Laid Min. 0.25inch Dens Deck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill-Tec #14 HD (concrete ony) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.33 ft2 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APPTA -97.5 SELF-ADHERING SYSTEMS: SC-158 Min. 22 ga., type B, Grade 33 steel or structural concrete Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 33 of 76 TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Insulation Layer(s) Base or Anchor Sheet Base Fasteners Roof Cover Attach Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: SC-159 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 24-inch o.c. at min. 2-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA -30.0* SC-160 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA -37.5* SC-161 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBSAA SBS-AA -45.0* SC-162 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 12-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-163 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 12-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -45.0* SC-164 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation. Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth See Note 2 18-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -45.0* SC-165 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 See Note 2 18-inch o.c. at min. 3.5-inch laps BP-AA, SBSAA SBS-AA -45.0* SC-166 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5inch towards the sheet-edge and spaced 18-inch o.c. within the min. 4-inch wide, heatwelded laps (Optional) SBS-TA SBS-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 34 of 76 TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Base or Anchor Sheet Insulation Layer(s) Base Fasteners Roof Cover Attach Ply Cap MDP (psf) SC-167 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill-Tec #12 (steel only) or #14 18-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-168 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid HW Smooth Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-169 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth See Note 2 12-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -52.5 SC-170 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5inch towards the sheet-edge and spaced 12-inch o.c. within the min. 4-inch wide, heatwelded laps (Optional) SBS-TA SBS-TA -52.5 SC-171 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2-3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates with Drill-Tec XHD Off-centered in the lap by 0.25inch towards the sheet-edge and spaced 12-inch o.c. within the min. 5-inch wide, heatwelded laps (Optional) SBS-TA SBS-TA -67.5 SC-172 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill-Tec XHD 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-173 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -82.5 SC-174 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet See Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP-TA SBS-TA, APP-TA -82.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 35 of 76 TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Base or Anchor Sheet Insulation Layer(s) Base Fasteners Roof Cover Attach MDP (psf) Ply Cap 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP-TA SBS-TA, APP-TA -82.5 BP-AA, SBSAA SBS-AA -105.0 See Note 2 (Drill-Tec 3” Standard Steel Plate; DrillTec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) SC-175 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination SC-176 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 See Note 2 18-inch o.c. at min. 3.25-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows SC-177 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth See Note 2 6-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -112.5 SC-178 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet See Note 2 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA -150.0 SC-179 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec #14 Fasteners with Drill-Tec 2 3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates 6-inch o.c. at min. 3.25-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows SBS-TA SBS-TA -150.0 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) Ruberoid HW Smooth SBS-TA -150.0 GAFGLAS #75 See Note 2 (Drill-Tec 3” SC-180 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Standard Steel Plate; DrillTec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) SELF-ADHERING SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 36 of 76 TABLE 2C: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Base or Anchor Sheet Insulation Layer(s) Base Fasteners Roof Cover Attach Ply Cap MDP (psf) SC-181 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet See Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA, SBS-TA or APP-TA SBS-SA, SBS-TA or APP-TA -30.0* SC-182 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet See Note 2 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -37.5 SC-183 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Self-Adhering Base/Ply Sheet See Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in one center row (Optional) SBS-SA SBS-SA -45.0* COLD-APPLIED SYSTEMS: SC-184 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 See Note 2 18-inch o.c. at min. 3-inch laps None SBS-CA or SBS-CA-1 -30.0* SC-185 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid 20 Smooth See Note 2 12-inch o.c. at min. 3-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA-1 -45.0* SC-186 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet See Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows None SBS-CA -45.0* SC-187 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 See Note 2 24-inch o.c. at min. 3-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA-1 -45.0 SC-188 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet See Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-CA at 2.0 gal/sq. SBS-CA at 2.0 gal/sq. -82.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 37 of 76 TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Base Insulation Layer Deck (See Note 1) Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY C-1. Primed concrete Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -140.0 C-2. Primed concrete Min. 0.5-inch EnergyGuard Perlite Recover Board HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-3. Primed concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-4. Primed concrete Min. 1.5-inch EnergyGuard Composite HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -270.0 C-5. Concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-6. Concrete Min. 0.25-inch Dens Deck Prime OB500 SBS-TA (Optional) One or more SBS-TA SBS-TA -300.0 C-7. Concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-8. Concrete Min. 0.25-inch Dens Deck Prime GAF 2Part SBS-TA (Optional) One or more SBS-TA SBS-TA -245.0 SELF-ADHERING SYSTEMS WITH BASE INSULATION LAYER ONLY C-9. Primed concrete Min. 1.5-inch EnergyGuard Ultra HA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APPTA -90.0 C-10. Primed concrete Min. 1.5-inch EnergyGuard RN HA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-11. Primed concrete Min. 1.5-inch EnergyGuard RN HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-12. Primed concrete Min. 1.5-inch EnergyGuard RA HA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-13. Primed concrete Min. 1.5-inch EnergyGuard RA HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-14. Concrete Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 C-15. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-16. Concrete Min. 0.25-inch Dens Deck OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -122.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 38 of 76 TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Base Insulation Layer Deck (See Note 1) Type Roof Cover Attach Base Ply Cap MDP (psf) C-17. Concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-18. Concrete Min. 1-inch EnergyGuard RN OB 500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -162.5 C-19. Concrete Min. 0.25-inch Dens Deck primed with ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5 C-20. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-21. Concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with ASTM D41 primer OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 C-22. Concrete Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA SBS-TA -300.0 C-23. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-24. Concrete Min. 1.5-inch EnergyGuard RN GAF 2Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-25. Concrete Min. 1.5-inch EnergyGuard RN GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-26. Concrete Min. 1.5-inch EnergyGuard RA GAF 2Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-27. Concrete Min. 1.5-inch EnergyGuard RA GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-28. Concrete Min. 0.25-inch Dens Deck Prime GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA SBS-TA -245.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY C-29. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 C-30. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 C-31. Primed concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra HA B-LL (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-32. Primed concrete Min. 0.5-inch EnergyGuard RN HA B-LL SBS-AA SBS-AA -172.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 39 of 76 TABLE 3A-1: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Base Insulation Layer Deck (See Note 1) Type Roof Cover Attach Base Ply Cap MDP (psf) C-33. Primed concrete Min. 1.5-inch EnergyGuard Ultra HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 C-34. Primed concrete Min. 1.5-inch EnergyGuard Ultra HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5 C-35. Primed concrete Min. 1-inch EnergyGuard RN HA B-LL One or more BP-AA, SBS-AA SBS-AA -292.5 OB500 SBS-CA-1 None SBS-CA-1 -60.0 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY C-36. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 40 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-37. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA (Optional) BP-AA SBS-AA or SBS-TA -112.5 C-38. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck Prime HA APP-TA (Optional) APP-TA APP-TA -127.5 HA BP-AA, SBS-AA (Optional) BP-AA, SBSAA SBS-AA -150.0 C-39. Primed concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum Fiber Roof Board C-40. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -172.5 C-41. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.5-inch EnergyGuard Perlite Recover Board HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 C-42. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-43. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-44. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA APP-TA (Optional) APP-TA APP-TA -240.0 C-45. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck or Dens Deck Prime HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -255.0 C-46. Primed concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 41 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-47. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 1.5-inch EnergyGuard Composite HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -270.0 C-48. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -307.5 C-49. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -150.0 C-50. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-51. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 C-52. Concrete Min. 1-inch EnergyGuard RH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix™ 307 Premium Asphalt Primer OB500 SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-53. Concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-54. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APPTA SBS-TA, APP-TA -240.0 C-55. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-TA (Optional) SBS-TA SBS-TA -300.0 C-56. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-57. Concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA or SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 42 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-58. Concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part SBS-TA or APPTA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -232.5 C-59. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck or Dens Deck Prime GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 SELF-ADHERING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER C-60. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA SBS-TA -232.5 C-61. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) APP-TA APP-TA -240.0 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -120.0 C-62. Concrete Min. 1.5-inch EnergyGuard RH C-63. Concrete Min. 1-inch EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board C-64. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck OB500 SBS-SA (Optional) SBS-TA, APPTA SBS-TA, APP-TA -122.5 C-65. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -127.5 C-66. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -150.0 C-67. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-68. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck; surface shall be primed with ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APPTA SBS-TA, APP-TA -167.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 43 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Ply (Optional) SBS-TA, APPTA SBS-TA, APP-TA -232.5 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier Cap MDP (psf) Base C-69. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra C-70. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -232.5 C-71. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -240.0 C-72. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APPTA SBS-TA, APP-TA -270.0 C-73. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APPTA SBS-TA, APP-TA -285.0 C-74. Concrete Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-75. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch Dens Deck Prime LRF-M WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -127.5 C-76. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-M SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -232.5 C-77. Concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation LRF-M SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APPTA SBS-TA, APP-TA -232.5 C-78. Concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -225.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 44 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-79. Concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-80. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck Prime GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -240.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-81. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 C-82. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -90.0 C-83. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 C-84. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -90.0 C-85. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA (Optional) EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 C-86. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA (Optional) EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 C-87. Primed concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra HA (Optional) EnergyGuard Polyiso Insulation, EnergyGuard Ultra HA B-LL (Optional) BP-AA, SBSAA SBS-AA -150.0 C-88. Primed concrete Min. 1.5-inch EnergyGuard Ultra HA (Optional) EnergyGuard Ultra HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 C-89. Primed concrete Min. 1.5-inch EnergyGuard Ultra HA (Optional) EnergyGuard Ultra HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5 C-90. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck or Dens Deck Prime HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -240.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 45 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-91. Primed concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck or Dens Deck Prime HA B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -240.0 C-92. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 C-93. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -90.0 C-94. Concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) EnergyGuard Ultra OB500 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 C-95. Concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) EnergyGuard Ultra OB500 B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 C-96. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 C-97. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 C-98. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 C-99. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 C-100. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 C-101. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -90.0 C-102. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part (Optional) EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 C-103. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part (Optional) EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 46 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-104. Concrete Min. 1.5-inch EnergyGuard Ultra GAF 2Part (Optional) EnergyGuard Ultra GAF 2Part B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 C-105. Concrete Min. 1.5-inch EnergyGuard Ultra GAF 2Part (Optional) EnergyGuard Ultra GAF 2Part B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5 C-106. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch Dens Deck or Dens Deck Prime GAF 2Part B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -240.0 C-107. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch Dens Deck or Dens Deck Prime GAF 2Part B-LL One or more BP-AA, SBS-AA SBS-TA or APP-TA -240.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-108. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 C-109. Concrete Min. 1.5-inch EnergyGuard RH OB500, LRF-M, M-OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M-OSFA SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -97.5 C-110. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-CA-1 None SBS-CA-1 -127.5 C-111. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -172.5 C-112. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck Prime GAF 2Part SBS-CA-1 None SBS-CA-1 -127.5 C-113. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part SBS-CA-1 None SBS-CA-1 -172.5 HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -255.0 OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -127.5 HYBRID COLD/HOT-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-114. Primed concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogenenous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board C-115. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 47 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-116. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -172.5 C-117. Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -240.0 CONVENTIONAL SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER: C-118. Concrete Min. 1.0-inch Foamular 250 or 2.0-inch STYROFOAM Deckmate Plus FA OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APPTA SBS-TA, APP-TA -240.0 C-119. Concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -277.5 C-120. Concrete Min. 1.5-inch, min. 1.25 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -87.5 C-121. Concrete Min. 1.5-inch, min. 1.25 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -87.5 C-122. Concrete Min. 1.5-inch, min. 1.5 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-123. Concrete Min. 1.5-inch, min. 1.5 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-124. Concrete Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-125. Concrete Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 Min. 0.25-inch Dens Deck Prime GAF 2Part SBS-SA (Optional) SBS-SA SBS-SA -87.5 SELF-ADHERING SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER: C-126. C-127. Concrete Min. 1.0-inch Foamular 250 OB500 Concrete Min. 1.5-inch, min. 1.25 pcf ASTM C578 expanded polystyrene GAF 2Part Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 48 of 76 TABLE 3A-2: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) C-128. Concrete Min. 1.5-inch, min. 1.25 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2Part SBS-SA (Optional) SBS-SA SBS-SA -87.5 C-129. Concrete Min. 1.5-inch, min. 1.5 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck Prime GAF 2Part SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-130. Concrete Min. 1.5-inch, min. 1.5 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2Part SBS-SA (Optional) SBS-SA SBS-SA -180.0 C-131. Concrete Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2Part SBS-SA (Optional) SBS-SA SBS-SA -240.0 A. The following are options for installation of a vapor barrier / temporary roof on the concrete deck prior to insulation placement. If asphaltic vapor barrier / temp roof is installed, concrete deck shall be primed with Matrix™ 307 Premium Asphalt Primer or ASTM D41 primer prior to its installation. Unless otherwise noted, system Maximum Design Pressure (MDP) is unaffected. If noted, maximum design pressure (MDP) shall be the lesser of that for the system in Table 3A, and that for the vapor barrier / insulation adhesive noted below: 1. For use with asphalt-applied insulation: One or two plies BP-AA One BP-AA base or ply sheet with SBS-AA, SBS-TA or APP-TA base or cap membrane One or two plies SBS-AA, SBS-TA or APP-TA base and/or cap membrane 2. For use with OB500 applied insulation: One or two plies BP-AA: MDP -352.5 psf Ruberoid 20 Smooth in Matrix™ 102 SBS Membrane Adhesive in full coverage: MDP -202.5 psf One ply Ruberoid Torch Smooth, Tri-Ply APP Smooth, Ruberoid HW 25 Smooth or Ruberoid HW Smooth: MDP -165.0 psf Deck primed with ASTM D41 primer followed by Liberty SBS Self-Adhering Base/Ply Sheet. The installed sheet is then heated with a torch to burn-off any poly-film on the top surface MDP -240.0 psf UnderRoof HT High Temperature Leak Barrier, self-adhered: MDP -37.5 psf UnderRoof 2 Polyester-Surfaced Leak Barrier, self-adhered: MDP -127.5 psf 3. For use with GAF 2-Part applied insulation: One or two plies BP-AA: MDP -262.5 psf Optional BP-AA or SBS-AA with SBS-AA cap membrane: MDP -270.0 psf Optional BP-AA or SBS-AA, SBS-TA or APP-TA base membrane with SBS-TA or APP-TA cap membrane: MDP -169.0 psf Optional SBS-SA base membrane with SBS-SA cap membrane: MDP -250.0 psf Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 49 of 76 TABLE 3A-3: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Temp Roof Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: C-132. Primed conc. One or two plies of GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 in hot Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 1.4-inch EnergyGuard Composite HA BP-AA or SBS-AA BP-AA or SBS-AA SBS-AA -202.5 C-133. Primed conc. One or two plies of GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 in hot Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board HA SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -232.5 C-134. Primed conc. SBS-CA, SBS-AA, SBS-TA or APP-TA base ply Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APPTA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -165.0 C-135. Primed conc. Liberty SA Self-Adhering Base/Ply Sheet; poly-film burned off Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APPTA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -240.0 SELF-ADHERING SYSTEMS: C-136. Primed conc. One or two plies of GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 in hot Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -232.5 C-137. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1-inch EnergyGuard RA, RH, RN OB500 (Optional) Additional layers base insulation OB500 SBS-SA None SBS-SA -37.5 C-138. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1-inch EnergyGuard RA, RH, RN OB500 (Optional) Additional layers base insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5 C-139. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1-inch EnergyGuard RA, RH, RN OB500 Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 SBS-SA None SBS-SA -37.5 C-140. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1-inch EnergyGuard RA, RH, RN OB500 Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5 C-141. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1-inch EnergyGuard RA, RH, RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 50 of 76 TABLE 3A-3: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Temp Roof Type Top Insulation Layer Attach Type Roof Cover Ply Cap MDP (psf) Attach Base OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5 C-142. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation C-143. Primed conc. UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered Min. 1-inch EnergyGuard RA, RH, RN OB500 (Optional) Additional layers base insulation OB500 SBS-SA None SBS-SA -45.0 C-144. Primed conc. UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered Min. 1-inch EnergyGuard RA, RH, RN OB500 Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0 C-145. Primed conc. UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-146. Primed conc. UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered Min. 1-inch EnergyGuard RA, RH, RN OB500 (Optional) Additional layers base insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -127.5 C-147. Primed conc. UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered Min. 1-inch EnergyGuard RA, RH, RN OB500 Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -127.5 C-148. Primed conc. SBS-CA, SBS-AA, SBS-TA or APP-TA base ply Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -165.0 C-149. Primed conc. Liberty SA Self-Adhering Base/Ply Sheet; poly-film burned off Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -240.0 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -37.5 COLD-APPLIED SYSTEMS: C-150. Primed conc. UnderRoof HT High Temperature Leak Barrier, self-adhered Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 1.5-inch EnergyGuard RH Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 51 of 76 TABLE 3A-3: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER Deck (See Note 1) Temp Roof C-151. Conc. (optional primer) C-152. Primed conc. System No. Base Insulation Layer Top Insulation Layer Type Roof Cover Attach Base Ply Cap MDP (psf) Type Attach Ruberoid 20 Smooth applied in Matrix™ 102 SBS Membrane Adhesive at 1.52.0 gal/sq. Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 SBS-CA None SBS-CA -45.0 UnderRoof 2 PolyesterSurfaced Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -97.5 Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -232.5 HYBRID HOT/COLD-APPLIED SYSTEMS: C-153. Primed conc. One or two plies of GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS FlexPly 6 in hot Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 52 of 76 TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Deck (See Note 1) System No. Roof Cover Primer Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: C-154. Concrete ASTM D41 APP-TA (Optional) APP-TA APP-TA -90.0 C-155. Concrete ASTM D41 BP-AA, SBS-AA BP-AA, SBS-AA SBS-AA -442.5 C-156. Concrete (Optional) ASTM D41 SBS-TA (Optional) SBS-TA SBS-TA -465.0 SELF-ADHERING SYSTEMS: C-157. Concrete ASTM D41 SBS-SA (Optional) SBS-SA SBS-SA -72.5 C-158. Concrete ASTM D41 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -140.0 Matrix™ 307 Premium Asphalt Primer B-LL BP-AA, SBS-AA SBS-AA -185.0 VENTING SYSTEMS: C-159. Concrete Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 53 of 76 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Struct. Base Insulation Layer LWC Type Coverboard Attach Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -155.0 OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -225.0 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -225.0 Min. 2.0-inch, min. 1.0 pcf, ASTM C578 expanded polystyrene OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -120.0 Elastizell (min. 200 psi) Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime or SECUROCK GypsumFiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -225.0 Concrete Elastizell (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -180.0 Concrete Elastizell (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -180.0 LWC-8. Concrete Elastizell (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -222.5 LWC-9. Concrete Elastizell (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -222.5 Concrete Min. 200 psi Mearlcrete LWIC (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -240.0 Concrete Mearlcrete (min. 300 psi) Min. 0.5-inch Structodek TD Concrete Elastizell (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra LWC-3. Concrete Elastizell (min. 200 psi) LWC-4. Concrete LWC-5. LWC-6. LWC-1. LWC-2. LWC-7. LWC-10. OB500 None OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Elastizell (min. 200 psi) Concrete Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 N/A Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 54 of 76 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck (See Note 1) Base Insulation Layer Coverboard System No. Struct. LWC-11. Concrete Mearlcrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board Concrete Elastizell, Celcore or Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf ASTM C578 expanded polystyrene GAF 2Part LWC-13. Concrete Elastizell, Celcore or Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf ASTM C578 expanded polystyrene LWC-14. Concrete Elastizell, Celcore or Mearlcrete (min. 200 psi) LWC-15. Type Attach Type Roof Cover Attach MDP (psf) Base Ply Cap GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBSAA, SBS-TA or APPTA SBS-AA, SBSTA or APP-TA -240.0 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -87.5 GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -87.5 Min. 1.5-inch, min. 1.5 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -180.0 Concrete Elastizell, Celcore or Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -180.0 LWC-16. Concrete Celcore (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -222.5 LWC-17. Concrete Celcore (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -222.5 LWC-18. Concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -240.0 LWC-19. Concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK GypsumFiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBSTA or APP-TA -240.0 Mearlcrete (min. 300 psi) Min. 0.5-inch Structodek TD OB500 None N/A SBS-SA (Optional) SBS-SA SBS-SA -122.5 LWC-12. LWC SELF-ADHERING SYSTEMS: LWC-20. Concrete Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 55 of 76 TABLE 1B-1: LIGHTWEIGHT INSULATING CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Struct Deck Anchor Sheet Fasteners Base Insulation LWC Type Attach Type LWC-21. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso LWC-22. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Top Insulation Attach Type Roof Cover Attach Base MDP (psf) Ply Cap SBS-AA, SBS-TA, APP-TA -75.0 CONVENTIONAL SYSTEMS: HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board HA BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 HA (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA B-LL BP-AA, SBS-AA SBS-AA, SBS-TA, APP-TA -75.0* VENTING SYSTEMS: LWC-23. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or structural concrete Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 56 of 76 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Structural Base LWC Roof Cover Attachment Ply Cap MDP (psf) Membrane Faster Ruberoid Mop Plus Granule (granules down) Drill-Tec Locking Impact Nail 6-inch o.c. at min. 4-inch side laps and 9-inch o.c. in two, equally spaced staggered center rows. (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 Fasten through LWC to structural deck 6-inch o.c. within 4-inch heat welded side laps (Optional) SBS-TA SBS-TA -52.5 CONVENTIONAL SYSTEMS: Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2inch thick top coat LWC-25. Min. 22 ga. type B, Grade 33 steel; 6’-6”spans or structural concrete Min 250-300 psi Approved cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Smooth #14 HD DrillTec fasteners and 2” Drill-Tec Double-Barbed Round Steel Plates LWC-26. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) BP-AA, SBSAA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 LWC-27. Structural concrete Mearlcrete (min. 300 psi) with optional min. 1 pcf Corrugated EPS Holey Board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 4-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -52.5 LWC-28. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or structural concrete Mearlcrete (min. 742 psi) min. 2inch thick top coat GAFGLAS FlexPly 6 Drill-Tec Base Sheet Fastener (1.2) 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. (Optional) BP-AA, SBSAA SBS-AA (polyester reinforced, D6164 only) -52.5 LWC-29. Min. 22 ga. type B, Grade 33 steel; 6 ft spans or structural concrete Min 250-300 psi Approved cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS FlexPly 6 See Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) BP-AA, SBSAA SBS-AA, SBS-TA -67.5 LWC-30. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Granule, Tri-Ply SBS Granule (granules down) Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -75.0 LWC-24. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 57 of 76 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Base Roof Cover Cap MDP (psf) Two plies BP-AA or SBS-AA SBS-AA -75.0 See Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) SBS-TA SBS-TA (polyester, D6164 only) -97.5 GAFGLAS FlexPly 6 Drill-Tec Base Sheet Fastener (1.2 in.) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBSAA SBS-AA (polyester, D6164 only) -127.5 Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2inch thick top coat StormSafe Anchor Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5 LWC-35. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 12-inch o.c. at min. 2-inch side laps and 12-inch o.c. at three equally spaced staggered center rows. BP-AA or SBS-AA SBS-CA-1 -45.0 LWC-36. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 2-inch side laps and 9-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS-AA SBS-CA-1 -45.0 LWC-37. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7.5-inch o.c. at min. 2-inch side laps and 7.5-inch o.c. at one center row. BP-AA or SBS-AA SBS-CA-1 -45.0 Structural LWC Membrane Faster LWC-31. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. LWC-32. Min. 22 ga. type B, Grade 33 steel; 5-ft spans or structural concrete Min 250 psi Approved cellular LWC with optional min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid HW Granule (granules down) Min. 22 ga. type B, Grade 33 steel; 6-ft spans or structural concrete Mearlcrete (min. 300 psi) with no EPS board. Note: To qualify the Mearlcrete under this assembly, a Drill-Tec Base Sheet Fastener (1.2 in.) shall achieve an average withdrawal of 146 lbf or greater when tested per TAS105 or ANSI/SPRI FX-1 LWC-33. Attachment Ply SELF-ADHERING SYSTEMS: LWC-34. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or structural concrete HYBRID HOT/COLD-APPLIED SYSTEMS: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 58 of 76 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Base Roof Cover Attachment Ply Cap MDP (psf) Structural LWC Membrane Faster LWC-38. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 3-inch side laps and 18-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS-AA SBS-CA-1 -45.0 LWC-39. Min. 22 ga., type B, Grade 33 steel; 5 ft spans or structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS-AA SBS-CA-1 -75.0 TABLE 4D: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (See Note 1) Structural Primer LWC Roof Cover Base Ply Cap MDP (psf) SELF-ADHERING SYSTEMS: LWC-40. Concrete Min. 250-300 psi Celcore LWIC ASTM D41 SBS-SA None SBS-TA -52.5 LWC-41. Concrete Min. 250-300 psi Celcore LWIC TOPCOAT PRECOTE SBS-SA None SBS-TA -100.0 LWC-42. Concrete Min. 250-300 psi Elastizell LWIC ASTM D41 SBS-SA None SBS-SA -137.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 59 of 76 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: CWF-1. Tectum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 CWF-2. Tectum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 CWF-3. Tectum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CWF-4. Tectum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 SELF-ADHERING SYSTEMS: CWF-5. Tectum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APPTA SBS-TA or APP-TA -45.0 CWF-6. Tectum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APPTA SBS-TA or APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 60 of 76 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Anchor Sheet Base Insulation Type Fasteners Attach Tectum GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail Tectum GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3inch lap and 18-inch o.c. in two, equally spaced, staggered center rows GAFGLAS #75 Base Sheet, TriPly #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Type Attach Top Insulation Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: CWF-7. CWF-8. 9-inch o.c. at the 3inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard (Optional) Min. 1-inch EnergyGuard HA Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBSAA, SBS-TA, APP-TA SBS-TA, APP-TA -82.5 HA BP-AA, SBS-AA (Optional) BP-AA, SBSAA, SBS-TA, APP-TA SBS-TA, APP-TA -82.5 HA Weather Watch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -82.5 SELF-ADHERING SYSTEMS: CWF-9. Tectum Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 (Optional) Min. 1-inch EnergyGuard Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 61 of 76 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Base Sheet Deck (See Note 1) Type Roof Cover Faster Attachment Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: CWF-10. Tectum GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 CWF-11. Tectum Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 CWF-12. Tectum Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12inch o.c. in two, equally spaced, staggered center rows (Optional) SBSTA SBS-TA -60.0 CWF-13. Tectum GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 CWF-14. Tectum Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7inch o.c. in two, equally spaced, staggered center rows (Optional) SBSTA SBS-TA -67.5 CWF-15. Tectum GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3-inch lap and 18inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -82.5 Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2-inch lap and 9inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA-1 -45.0* HYBRID HOT/COLD-APPLIED SYSTEMS: CWF-16. Tectum GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 62 of 76 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Deck (See Note 1) System No. Type Top Insulation Layer Attach Roof Cover Type Attach Base Ply Cap MDP (psf) G-1. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard RH OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA None SBS-SA -87.5 G-2. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -105.0 G-3. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard RN OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -147.5 G-4. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard RH OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBSTA SBS-TA -190.0 Cap MDP (psf) TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Anchor Sheet Type Fasteners Base Insulation Attach Type Top Insulation Attach Type Roof Cover Attach Base Ply VENTING SYSTEMS: G-5. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet G-6. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 1.8-inch Drill-Tec Locking Impact Nail or Drill-Tec Base Sheet Fastener (1.2 in) 9-inch o.c. at the 2inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA or SBSAA BP-AA, SBS-AA SBS-AA or SBSTA -45.0* HA None N/A B-LL Two plies SBS-AA SBS-AA -45.0* Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 63 of 76 TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. G-7. Deck (See Note 1) Base Insulation Layer Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Top Insulation Layer Type Fasteners Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Drill-Tec Polymer Gyptec Fastener with Drill-Tec Gyptec Plate Roof Cover Attach 1 per 1.3 ft2 Base Ply Cap (Optional) BPAA, SBS-AA or SBS-TA BP-AA or SBS-AA SBS-AA or SBS-TA MDP (psf) -62.5* TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Base Sheet Deck (See Note 1) Type Faster Roof Cover Attachment Ply Cap MDP (psf) CONVENTIONAL SYSTEMS: G-8. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 G-9. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBSTA or APP-TA -45.0* G-10. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -45.0* G-11. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA, SBSTA or APP-TA SBS-AA, SBSTA or APP-TA -50.0* G-12. Existing sound gypsum or gypsum plank Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 G-13. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBSTA SBS-TA -60.0 G-14. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) BPAA, SBS-AA, SBSTA or APP-TA SBS-AA, SBSTA or APP-TA -57.5* G-15. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, Tri-Ply Ply 4, GAFGLAS FlexPly 6, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BPAA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 G-16. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBSTA SBS-TA -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 64 of 76 TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Base Sheet Deck (See Note 1) Type Faster Roof Cover Attachment Ply Cap MDP (psf) HYBRID HOT/COLD-APPLIED SYSTEMS: G-17. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA-1 -45.0* G-18. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 7.5-inch o.c. at min. 2-inch laps and 7.5-inch o.c. at one center rows BP-AA or SBS-AA SBS-CA-1 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 65 of 76 TABLE 7A-1: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (See Notes 1 & 11) Base Insulation Layer Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY R-1. Existing asphaltic roof cover Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -140.0 R-2. Existing asphaltic roof cover Min. 0.5-inch EnergyGuard Perlite Recover Board HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 R-3. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 R-4. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Composite HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -240.0 R-5. Existing granule surface cap sheet Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-6. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 R-7. Existing asphaltic roof cover Min. 0.25-inch Dens Deck Prime OB500 SBS-TA (Optional) One or more SBS-TA SBS-TA -120.0 R-8. Existing granule surface cap sheet Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-9. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 R-10. Existing asphaltic roof cover Min. 0.25-inch Dens Deck Prime GAF 2Part SBS-TA (Optional) SBS-TA SBS-TA -245.0 SELF-ADHERING SYSTEMS WITH BASE INSULATION LAYER ONLY R-11. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra HA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -90.0 R-12. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN HA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-13. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-14. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA HA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-15. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -217.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 66 of 76 TABLE 7A-1: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (See Notes 1 & 11) Base Insulation Layer Type Roof Cover Attach Base Ply Cap MDP (psf) R-16. Existing granule surface cap sheet Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-17. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APPTA -97.5 R-18. Existing asphaltic roof cover Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-19. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-20. Existing asphaltic roof cover Min. 0.25-inch Dens Deck OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APPTA -120.0 R-21. Existing asphaltic roof cover Min. 0.25-inch Dens Deck primed with ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APPTA -120.0 R-22. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APPTA -120.0 R-23. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APPTA -120.0 R-24. Existing asphaltic roof cover Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA SBS-TA -120.0 R-25. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 R-26. Existing granule surface cap sheet Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6inch o.c. WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-27. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, MOSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -75.0 R-28. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, MOSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA or APP-TA SBS-TA or APPTA -75.0 R-29. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, MOSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 67 of 76 TABLE 7A-1: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (See Notes 1 & 11) Base Insulation Layer Type Roof Cover Attach Base Ply Cap MDP (psf) R-30. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN GAF 2Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-31. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-32. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA GAF 2Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-33. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-34. Existing asphaltic roof cover Min. 0.25-inch Dens Deck Prime GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBS-TA SBS-TA -245.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY R-35. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-36. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA B-LL One or more BP-AA, SBS-AA SBS-TA or APPTA -150.0 R-37. Existing smooth- or granule-surface BUR, granule-surface modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-38. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-39. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra HA B-LL One or more BP-AA, SBS-AA SBS-TA or APPTA -172.5 R-40. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -225.0 R-41. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, MOSFA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 R-42. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, MOSFA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -225.0 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-CA-1 None SBS-CA-1 -127.5 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-43. Existing mineral surface cap or asphalt BUR Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 68 of 76 TABLE 7A-1: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Roof Cover Attach Base Ply Cap MDP (psf) R-44. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA SBS-CA-1 None SBS-CA-1 -172.5 R-45. Existing smooth APP, mineral surface cap or asphaltic BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-CA-1 None SBS-CA-1 -60.0 R-46. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA-1 None SBS-CA or SBSCA-1 -97.5 R-47. Existing asphalt BUR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -120.0 R-48. Existing smooth APP or mineral surface cap Min. 0.25-inch Dens Deck Prime OB500 SBS-CA-1 None SBS-CA-1 -127.5 R-49. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -165.0 R-50. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -172.5 R-51. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, MOSFA SBS-CA or SBS-CA-1 None SBS-CA or SBSCA-1 -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-52. Existing mineral surface cap or asphalt BUR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -127.5 R-53. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -172.5 R-54. Existing asphalt BUR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -120.0 R-55. Existing smooth APP or mineral surface cap Min. 0.25-inch Dens Deck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -127.5 R-56. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -165.0 R-57. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -172.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 69 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) CONVENTIONAL SYSTEMS (BASE AND TOP LAYER INSULATION): R-58. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA (Optional) BP-AA SBS-AA or SBS-TA -112.5 R-59. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -127.5 R-60. Existing smooth- or granulesurface BUR, granule-surface modified bitumen or smoothsurface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum Fiber Roof Board HA BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA -150.0 R-61. Existing granule surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-TA, APP-TA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -172.5 R-62. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -172.5 R-63. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.5-inch EnergyGuard Perlite Recover Board HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -187.5 R-64. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBSTA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 R-65. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-TA (Optional) SBSTA SBS-TA -232.5 R-66. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board HA APP-TA (Optional) APPTA APP-TA -240.0 R-67. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Min. 1.5inch EnergyGuard Composite or min. 0.25-inch Dens Deck Prime HA BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 70 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 OB500 Min. 0.25-inch Dens Deck or Dens Deck Prime OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -150.0 OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA -150.0 OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 R-74. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6-inch o.c. Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6-inch o.c. BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 R-75. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M-OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M-OSFA BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA -75.0 R-76. Existing granule-surface BUR or modified bitumen or smoothsurface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M-OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M-OSFA BP-AA, SBS-AA (Optional) BPAA, SBS-AA SBS-AA -150.0 R-68. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN R-69. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN R-70. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN R-71. Existing smooth- or granulesurface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN R-72. R-73. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 71 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) R-77. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-78. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part BP-AA or SBS-AA (Optional) BPAA, SBS-AA, SBSTA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 R-79. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part SBS-TA or APPTA (Optional) BPAA, SBS-AA, SBSTA or APP-TA SBS-AA, SBS-TA or APP-TA -232.5 Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck or Dens Deck Prime GAF 2Part BP-AA, SBS-AA, SBS-TA or APPTA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 R-80. SELF-ADHERING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER R-81. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -127.5 R-82. Existing granule surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -172.5 R-83. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA, APP-TA SBS-TA, APP-TA -240.0 R-84. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -97.5 R-85. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBSSA SBS-TA or APP-TA -120.0 R-86. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -120.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 72 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) R-87. Existing smooth- or granulesurface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -127.5 R-88. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -150.0 R-89. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBSSA SBS-SA -152.5 R-90. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck; surface shall be primed with ASTM D41 primer OB500 SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -165.0 R-91. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -165.0 R-92. Existing smooth- or granulesurface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board OB500 SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -225.0 R-93. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (primer optional) OB500, 6-inch o.c. SBS-SA (Optional) SBSTA, APP-TA SBS-TA, APP-TA -240.0 R-94. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6-inch o.c. Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6-inch o.c. WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -240.0 R-95. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M-OSFA Min. 0.25-inch Dens Deck Prime LRF-M, M-OSFA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -75.0 R-96. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M-OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -75.0 R-97. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M-OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -75.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 73 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Top Insulation Layer Type Attach Type Roof Cover Attach Base Ply Cap MDP (psf) R-98. Existing granule-surface BUR or modified bitumen or smoothsurface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M-OSFA Min. 0.25-inch Dens Deck Prime LRF-M, M-OSFA WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -127.5 R-99. Existing granule-surface BUR or modified bitumen or smoothsurface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M-OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M-OSFA SBS-SA or WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -225.0 R-100. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -232.5 R-101. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Min. 0.25-inch Dens Deck Prime GAF 2Part WeatherWatch XT Mat Surfaced Leak Barrier (Optional) SBSTA or APP-TA SBS-TA or APP-TA -240.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-102. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-103. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) HA B-LL One or more BPAA, SBS-AA SBS-TA or APP-TA -90.0 R-104. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-105. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation HA B-LL One or more BPAA, SBS-AA SBS-TA or APP-TA -90.0 R-106. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA (Optional) EnergyGuard HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-107. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA (Optional) EnergyGuard HA B-LL One or more BPAA, SBS-AA SBS-TA or APP-TA -150.0 R-108. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra HA (Optional) EnergyGuard Ultra HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 74 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) R-109. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra HA (Optional) EnergyGuard Ultra HA B-LL One or more BPAA, SBS-AA SBS-TA or APP-TA -172.5 R-110. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck or Dens Deck Prime HA B-LL (Optional) One or more BP-AA, SBS-AA SBS-AA -240.0 R-111. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra HA Min. 0.25-inch Dens Deck or Dens Deck Prime HA B-LL One or more BPAA, SBS-AA SBS-TA or APP-TA -240.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-112. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-CA-1 None SBS-CA-1 -120.0 R-113. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA SBS-CA-1 None SBS-CA-1 -127.5 R-114. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 R-115. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -97.5 R-116. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -120.0 R-117. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-CA-1 None SBS-CA-1 -127.5 R-118. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -165.0 R-119. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA-1 None SBS-CA-1 -172.5 R-120. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M-OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M-OSFA SBS-CA or SBSCA-1 None SBS-CA or SBS-CA-1 -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 75 of 76 TABLE 7A-2: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) System No. Base Insulation Layer Substrate (See Notes 1 & 11) Type Top Insulation Layer Attach Type Roof Cover Attach Base Ply Cap MDP (psf) R-121. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -120.0 R-122. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN HA Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board HA BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -127.5 R-123. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -120.0 R-124. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -127.5 R-125. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -165.0 R-126. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA-1 -172.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.11.04-R15 for FL5680-R15 Revision 15: 04/06/2015 Appendix 1, Page 76 of 76