NetXtend Cell Site Series Integrated Enclosure Solution Outside Plant for

advertisement
Outside Plant for
Business-Critical Continuity™
NetXtend™ Cell Site Series
Integrated Enclosure Solution
Features & Benefits
Positive pressure airflow
design — maintains a clean and
safe environment for network
electronics
A quick and cost-effective way to deploy and protect the latest mobile networking technology
Single, configurable platform
design — meets all your DC
power, radio and battery
requirements
In the race to attract customers by providing more mobile services and greater
data transfer, wireless carriers must
quickly embrace and deploy ever-more
sensitive networking technology at their
cell sites. As the industry moves steadily
toward LTE (Long Term Evolution) and
other 4th generation mobile broadband
standards, both carriers and OEMs are
looking for the fastest ways to get this
equipment up and running, and keep it at
peak performance to maintain customer
satisfaction and protect their revenue
streams.
n
n
Unique temperature controlled zones — individual
compartments provide optimal,
Freon-free cooling with long
term utility savings
n
Adjustable multi-chamber
design — internal panels enable
custom thermal solutions while
maximizing rack space
n
Single-point control system —
combines thermal control,
power access and alarm
monitoring
n
Reversible chamber doors —
provide easy access in stringent
deployment areas
n
Low maintenance — maximizes
reliability, minimizes utility costs
n
360° top cable access with
Roxtec® entrance boots —
optimizes site cabling and
prevents water intrusion
n
Multiple cabinet deployment —
minimizes site lease costs and
maximizes configuration flexibility
n
GR-487 and Seismic Zone
4 tested — to meet industry
safety standards
n
2
NetXtend™ Cell Site Enclosures —
Emerson’s NetXtend™ Cell Site Series of
integrated enclosures provides custom
cell site deployment solutions for electronic equipment by utilizing common
structures and components. This unique
series of cabinets offers multiple, fieldconfigurable chambers and temperature
controlled environmental zones within
a single enclosure to provide the ideal
environment for each piece of equipment. Battery backup assures continued
operation when commercial power is
interrupted.
By eliminating the need for permitting
and construction of shelters, fieldconfigurable NetXtend™ Cell Site Series
enclosures reduce deployment cycles and
also provide flexibility for the inevitable
configuration changes that next-generation mobile broadband technology
demands.
Easily configurable, these enclosures support
distributed BTS applications, as well as power and battery
back-up deployments.
8
3
1
9
4
2
5
10
1
1
6
7
Battery Cabinet (front)
1
2
3
Thermoelectric Cooler
Forced Air Ventilator
RF Equipment Racks (19-in.)
Power Cabinet (back)
4
5
6
7
DC-DC Converter Shelf
8
9
Battery Shelf
10 Removable Access Panel
-48V Distribution Panel
Exhaust Vent
Removable Access Panel
Mounting Plinth (optional)
3
Enclosure Flexibility
NetXtend™ Cell Site Series enclosures enable you to quickly and economically create
the ideal operating environment for each sensitive electronic component — without
designing and fabricating a unique enclosure for every site and every application.
Plus, once an enclosure is deployed, it can be reconfigured in the field to accommodate new equipment and new requirements.
Roof Panel
Walls, Panels & Doors
Racks and Accessories
The roof panel is removable to provide
access to internals for cabling and
maintenance. The panel is alarmed to
prevent unknowingly leaving the panel
open after servicing the equipment. An
audible alarm alerts the technician on
the site, and the alarm is also communicated to the NOC (Network Operations
Center), should the technician leave the
site without securing the panel.
Modular panels and doors are combined
to create divided chambers within
the enclosure that provide different
thermal zones to satisfy OEM equipment environmental needs. After initial
deployment, as technology evolves and
equipment changes, chambers can be
expanded or decreased in the field by
moving partitions, rather than requiring
complete enclosure replacement.
NetXtend™ Cell Site enclosures are built
with 23" equipment racks. 23" to 19"
adapters are available to support different OEM equipment such as RxAIT
(Receive Antenna Interface Tray) equipment, distributed BTS systems, and other
RF and power distribution components.
Doors with gaskets are designed to
hinge from either side and can be
changed from one side to the other in
the field to accommodate the space
requirements of the installation.
Exterior panels are aluminum. The inner
frame--the main structural component-is steel. All surfaces are protected with
our patented multistage powder finishing process to meet EPA standards.
The finish meets GR-487 requirements,
including salt fog.
4
Mounting
NetXtend™ Cell Site Series enclosures are
designed for pad or grate mounting. An
optional mounting plinth is available with
six bolt locations. Installation of bolts in
all six positions meets requirements for
Zone 4 seismic applications.
Climate Control Solutions
Whatever climate or heat dissipation requirements may arise, there is a climate control solution available to keep your equipment operating within its
optimum temperature range. Options include a variety of environmentally
friendly solutions such as positive-pressure forced air cooling, Freon-free
thermoelectric coolers, heat exchangers, fan cooling, convection cooling and
combinations of the above to meet more dynamic requirements.
The integrated Environmental Control Unit (ECU) monitors conditions in
each chamber and provides power controls and alarms to/from the applicable thermal components. Climate control systems are integrated into
the door or panels at the factory and are field configurable by adjusting the
software in the ECU to accommodate changes in thermal requirements of
contained equipment.
Battery Choices
Battery backup assures continued operation during loss of commercial
power, keeping your cell site up and running and keeping your revenue
stream flowing. NetXtend™ Cell Site Series enclosures are available with -48V
and +24V battery shelf options. Cabinets can hold up to 20 batteries by combining chambers, while still meeting Seismic Zone 4 requirements. Battery
shelf compartments are isolated from electronics compartments to allow for
optimum thermal zones for each type of equipment in the cabinet.
5
Power Cabinet
NetXtend™ Cell Site Power Cabinets offer
three sealed chambers for DC power,
ancillary equipment and batteries. The DC
power chamber is configured with either
a +24V NetSure® 700 system or a -48V
NetSure® 701 system. The center and bottom chambers can be combined to house
additional batteries, if desired. The cabinet comes equipped with a 10-position
ground bar and 50-pair Phoenix® terminal
block. Two optional 200/200A automatic
transfer switches can be mounted to the
side of this cabinet.
Specifications — Power Cabinet
Thermal Solutions
Power Chamber
Forced Air – Positive Pressure
11-22 RU available space
Ancillary Equipment Chamber
Thermoelectric Cooler – 200W
0-18 RU available space
Battery Chamber
Thermoelectric Cooler – 200W
0-21 RU available space
NOTE: Combine the center and bottom chamber to house up to 3 shelves of batteries.
Equipment
Optional Auto Transfer Switch
Generator Connection
Ground Bar
Terminal Block
200/200 A
Micrin® Cam-Lok
10 positions
50-pair Phoenix® block
Ordering Information — Power Cabinet
6
Emerson
Part No.
Description
DC Power System
Rack Space
Dimensions
(H x W x D)
F2009270
+24V Power Cabinet
NetSure® 700 DC Power System
42 RU
86" x 32" x 31"
F2008213
+24V Power Cabinet e/w ATS
NetSure 700 DC Power System
42 RU
86" x 32" x 31"
F2009274
-48V Power Cabinet
NetSure 701 DC Power System
42 RU
86" x 32" x 31"
F2009275
-48V Power Cabinet e/w ATS
NetSure® 701 DC Power System
42 RU
86" x 32" x 31"
®
®
Battery Cabinet
NetXtend™ Cell Site Battery Cabinets are
equipped with five battery shelves. This
cabinet houses up to (10) +24V or (5)
-48V battery strings. The cabinet includes
a 10-position ground bar and 12-pair
Phoenix® terminal block. Two 200 watt
thermoelectric coolers are mounted on
the exterior.
Specifications — Battery Cabinet
Battery String Capacity
(10) +24V Strings Max
or (5) -48V Battery Strings
(2) 200 Watt Thermoelectric Coolers
Thermal Solution
Ground Bar
Terminal Block
10 positions
12-pair Phoenix® block
Ordering Information — Battery Cabinet
Emerson
Part No.
Description
Rack Space
Dimensions
(H x W x D)
F2008214
+24V Battery Cabinet e/w 5 battery shelves
42 RU
86" x 32" x 31"
F2008250
-48V Battery Cabinet e/w 5 battery shelves
42 RU
86" x 32" x 31"
7
Distributed BTS Site Support Cabinet
The Distributed BTS Site Support Cabinet
is designed with a reversible front/back
door for easy access in stringent deployment areas. This cabinet can be equipped
with DC-DC converters, power distribution, battery shelves and a mounting
plinth. Also included are a 10-position
ground bar and a 12-pair Phoenix®
terminal block. Two optional 200 watt
thermoelectric coolers are mounted on
the exterior. Converters are easily accommodated but must be ordered separately.
Specifications — Distributed BTS Site Support Cabinet
Reversible Front/Back Door
Weight Battery String Capacity
Thermal Solution
Ground Bar
Terminal Block
Converters
Yes
990 lbs.
(4) +24V Strings Max
(2) 200 Watt Thermoelectric Coolers 10 positions
12-pair Phoenix® block
Order separately
Ordering Information — Distributed BTS Site Support Cabinet
Emerson
Part No.
8
Description
Rack Space
Dimensions
(H x W x D)
F2008242
+24V Distributed BTS Site Support Cabinet e/w DC-DC converter shelf, 42 RU
-48V distribution panel, battery shelf and mounting plinth
90" x 32" x 31"
F2009280
-48V Distributed BTS Site Support Cabinet, e/w distribution panel,
battery shelf and mounting plinth
90" x 32" x 31"
42 RU
Distributed BTS Cabinet (front)
Distributed BTS Cabinet (back)
9
DC Power Integration
NetXtend™ Cell Site Series enclosures utilize Emerson Network Power’s NetSure®
DC power technology platform to
ensure the reliability of every active OSP
enclosure. Emerson Network Power has
been an industry leader in power solutions since 1909, with real-world, global
knowledge of all types of telecom DC
power needs.
Compact, modular, NetSure® DC power
systems provide more space for revenuegenerating equipment in the enclosure
and can be configured for 19" or 23" rack
mounting. They deliver constant power
to meet load or recharge demand, and
comply with global standards.
Units are available to provide -48V and
+24V power. They operate on 120 or
220V single-phase AC power, 50 or 60
Hz, to accommodate global differences.
Remote access options allow users to
view, control and interact with installations where suitable communication links
are available.
AC Distribution / ATS
To assure reliable transfer of business-critical loads to emergency sources
and provide over-current protection and surge protection, an Automatic
Transfer Switch (ATS) can be mounted directly on the enclosure or separately
mounted on an H frame or other arrangement at the cell site.
Emerson’s ASCO® 7000 Series switches combine best-in-class technology
from world-class manufacturers with a comprehensive offering of options
and capabilities. Key features include commercial and generator power
breakers, a 42-position Square D load center, customer-specified TVSS
(Transient Voltage Surge Suppression) and a generator receptacle or cam-lok
assembly for engine-generator connections.
If cabinet mounting is specified, the ATS is mounted on the cabinet at the
factory. ASCO® ATS units are UL 1008 certified and meet NFPA and NEC
requirements for emergency and standby power systems.
10
Emerson Network Power
provides a complete range of communications
network infrastructure solutions and services
built on an industry-leading reputation for
quality, reliability and value
Enclosure Assembly, Integration and Testing
Emerson Network Power has the industry
experience and in-house product knowledge to recommend, engineer, integrate,
implement and support NetXtend™ Cell
Site Series enclosures that you can confidently deploy as your network grows.
When we configure a new Cell Site Series
enclosure in one of our regional configuration centers, we integrate the climate
control, DC power and backup, alarms,
accessories and customer equipment.
Prior to production, a skilled test team
operates the completed enclosure in our
thermal and acoustic chambers. If necessary, we modify the configuration to
reduce the chance of encountering any
unexpected glitches once the units are
installed in the field.
The local presence of a global organization
To be profitable, your wireline and wireless networks must be properly deployed
and individual sites must perform reliably,
night and day. Emerson Network Power
understands this and offers a wide array of
global installation and support services.
Our experienced technicians will conduct
site surveys of your current installations,
and recommend and engineer the necessary enclosure and power solutions to
accomplish your goals. We will prepare
prints and other documentation and
pre-stage and configure all equipment to
assure efficient installation. We will install
and test enclosures and power systems
prior to going on line. And we will provide
post-installation maintenance contracts
and emergency services to keep all systems running efficiently.
In short, you can focus on keeping your
customers connected, knowing you have
Emerson Network Power global service
coverage, with over 150 service locations
worldwide and 2,000 certified professionals with local knowledge behind you.
11
Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering
together to provide innovative solutions for customers in industrial, commercial, and consumer markets through its
network power, process management, industrial automation, climate technologies, and appliance and tools businesses.
For more information, visit: Emerson.com.
Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™
from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network
Power provides innovative solutions and expertise in areas including AC and DC power, precision cooling, embedded
computing and power, integrated racks and enclosures, power switching and controls, infrastructure management, and
connectivity. All solutions are supported globally by local Emerson Network Power service technicians. For more
information on Emerson Network Power’s full suite of solutions specifically supporting the communications network
infrastructure, including NetSpan™, NetReach™ and NetXtend™ outside plant enclosures and equipment, NetSure® DC
power systems, and NetPerform™ Optimization, Design & Deployment services, visit:
EmersonNetworkPower.com/EnergySystems.
Learn more about Emerson Network Power products and services at: EmersonNetworkPower.com.
This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be
used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson
Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service.
Emerson®, Emerson Network Power™, Business-Critical Continuity™, ASCO®, NetSpan™, NetReach™, NetXtend™ and NetSure® are trademarks of Emerson Electric Co.
and/or one of its subsidiaries.
Additionally, this brochure references the following company trademarks: Phoenix®, Micrin® and Roxtec®. Names of companies and products are trademarks or registered
trademarks of the respective companies. Any questions regarding usage of trademark names should be directed to the original manufacturer.
Emerson Network Power
Energy Systems, World Headquarters
4350 Weaver Parkway, Warrenville, IL 60555 USA
Toll Free: 800-800-1280 (USA and Canada)
Telephone: 440-246-6999 Fax: 440-246-4876
Web: EmersonNetworkPower.com/EnergySystems
Emerson Network Power.
The global leader in enabling Business-Critical Continuity™.
AC Power
Connectivity
DC Power
EmersonNetworkPower.com
Embedded Computing
Embedded Power
Outside Plant
Power Switching & Controls
Racks & Integrated Cabinets
Services
Infrastructure Management & Monitoring
Precision Cooling
Surge Protection
© 2010 Emerson Network Power Energy Systems, North America, Inc. All rights reserved.
Code: OSP-128650
June 2010
Download