Avtron LCV Resistive/Reactive Load Bank - 3125 to 6250 KVA Testing Your Emergency Standby Generator with a Load Bank Means Reliability When it Matters Most. Key Features •Highest Capacity in the Industry •Provides Resistive and Reactive Loading •Rugged ISO Style Container •PLC Based Load Control •Local and Remote Load Control The Avtron Model LCV Load Bank is used for high power resistive/reactive testing of AC generating systems. The Avtron LCV load bank is designed to provide high capacity resistive and reactive loading of AC power systems such as diesel generator sets, turbines, or Uninterruptible Power Supplies (UPS). Many specifications and local codes demand that such testing be performed at less than unity power factor, typically 0.8 p.f. lagging. The LCV load bank is ideal for high power resistive and reactive testing of AC generating systems in factory production lines or in the field after installation. The LCV load bank combines resistive load (KW) with reactive load (KVAR) to achieve a 0.8 p.f. This combination provides a true test of the actual generator or UPS nameplate rating (KVA) and simulates a “real-world” load. The LCV incorporates state-of-the-art load bank design features with the highest capacity in the industry (20' [6096] container). The resistor elements, iron-core reactors, blowers, and controls are all manufactured from the highest quality components available. •Easy Interconnection and Operation Superior Avtron quality combined with simple operation and maintenance will provide years of trouble free service. Avtron’s extensive line of Load Bank and Industrial Resis­tor Products are solid performers used throughout the world. For total technical support or additional information, please contact Avtron at (216) 573-7600 or LBsales@Emerson.com. Quality System Certified to ISO 9001 LCV 3750 KVA Resistive/ Reactive Avtron Load Bank. Avtron LCV Resistive/Reactive Load Bank - 3125 to 6250 KVA LOAD CONNECTION COMPARTMENT Specifications subject to change without notice. Construction The load bank consists of a rugged ISO style container housing the resistive and reactive components, blowers, associated controls, and interconnections. The container features air intakes on the sides of the container with vertical exhaust through the roof. Typical Capacity Ratings C BKVAR A Available Load Step Resolution: 25KW, 18.75 Total Load KVA at 0.8 p.f. Resistive Load KW Reactive Load KVAR 3125 2500 1875 3750 3000 2250 5000 4000 3000 Options 6250 5000 3750 •SIGMA™ Network Control Resistor Elements The resistive elements are manufactured of a corrosion resistant chromium alloy wire and are fully supported with stainless steel rods for long life. Reactive Elements Load Bank Weight (approx.) 3125 or 3750 KVA: 28,600 lbs. [13,000 kg] 5000 KVA: 32,700 lbs. [14,800 kg] 6250 KVA: 36,300 lbs. [16,500 kg] •Heavy Duty Dual Axle Trailer NOTE Standard voltage is 480 VAC, 3 phase, 60 Hz. Other voltages and frequencies are available. Consult factory. •Cable Reels The reactive elements are of non-saturating single and 3 phase iron-core construction impregnated with high dielectric varnish. 96.00 [2438.00] 17.00 MAX [432.00] Control Power 120 VAC, single phase, 60 Hz provided by an integral control transformer. Metering Digital metering with data logging is provided to measure voltage, current, frequency, KW, KVAR, and power factor. BOLTED & HINGED ENTRY DOOR FOR SERVICE/ACCESS Cooling The resistive elements are cooled by integrally mounted blower motors each rated 10 HP, 460 VAC, 3 phase, 60 Hz. Controls The LCV load bank features both local and remote load control. The remote hand held controller is rugged and compact (7"x 7"x 2"). The controller is easy to operate and load values are activated by pressing a membrane style keypad. All resistive and reactive functions are displayed on a LCD display. A hard wired E-stop push button is also provided. The remote controller communicates with the Load Bank PLC via 200' of control cable in (2) 100' increments with MS style connectors. 102.00 [2591.00] CONTROL COMPARTMENT 238.50 [6058.00] VERTICAL EXHAUST AIR VERTICAL EXHAUST AIR EXHAUST HATCHES (MAY BE REMOVED FOR SHIPPING) BOLT-ON ACCESS PANELS EXTERNAL BLOWER CONTROL POWER CONNECTION BOX AIR INTAKE (TYPICAL) Protection This load bank features branch circuit fusing on all load steps and overtemperature protection. Air switches on the blowers are electrically interlocked to remove load if the airflow is not sufficient to provide proper cooling. Emerson Network Power Avtron • 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A. 216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com EmersonNetworkPower.com/loadbank FORKLIFT POCKETS All dimensions are in inches [millimeters]. Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. All the other marks are the property of their respective owners. Communicator EXT™ is a trademark of Electro Industries/GaugeTech. ADMS™ is a trademark of Avtron. SIGMA™ is a trademark of NJ Froment & Co. Ltd. Specifications subject to change without notice. ©2015 Emerson Network Power Bulletin 432• Rev. D