Columbine Hall - Third Floor Classrooms AV Upgrade 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918 Vicinity Map ABBREVIATIONS INSTALL COMMON WORK CONDUIT SLEEVES EC EC 1 PENETRATION GC GC 5,7 HANGER SUPPORTS FOR CONDUITS EC EC 1 HANGER SUPPORTS FOR CABLE SUPPORTS TC TC 2 WIDE BASE CABLE SUPPORTS (J-HOOKS) TC TC 2 STRAPS/SLINGS TC TC 2 ELECTRICAL FOR COMMUNICATIONS SYSTEMS CONDUIT, FITTINGS, PULL STRINGS EC EC 1 JUNCTION BOXES EC EC 1 DEVICE BOXES EC EC 1 PULL BOXES EC EC 1 TABLE-TOP INTERFACE (ROUGH IN) AVC AVC 4 TABLE-TOP INTERFACE (DEVICE) AVC AVC TC TC TELECOMMUNICATIONS (COMMUNICATIONS CABLING SYSTEM) AUDIOVISUAL SYSTEM(S) A. LOUDSPEAKERS AVC AVC HANGER WIRE SUPPORTS FOR LOUDSPEAKERS WITHIN LAYING CEILINGS AVC AVC MICROPHONES AVC AVC EQUIPMENT RACKS AVC AVC ANTENNA AVC AVC PROJECTION SCREEN AVC AVC INTERFACE PLATES AVC AVC PROJECTORS AVC AVC CAMERAS AVC AVC PODIUM AVC AVC VOLUME CONTROL AVC AVC CONTROL PANEL AVC AVC SCREEN SWITCH AVC AVC STRUCTURAL SUPPORTS FOR AV EQUIPMENT GC GC 9 GENERAL NOTES COMPONENTS, ENTITY, AND FURNISH AND INSTALL RESPONSIBILITIES INDICATED ARE RECOMMENDATIONS ONLY AND PROVIDED AS A COURTESY TO CONTRACTOR. B. SOME COMPONENTS AND ASSOCIATED FURNISH AND INSTALL RESPONSIBILITIES MAY NOT BE INDICATED ON THIS MATRIX. C. THE DETAIL FURNISH / INSTALL CALLOUT ANNOTATION PROVIDES SPECIFIC RECOMMENDATIONS THAT SUPERSEDE GENERAL RECOMMENDATIONS FOUND IN THE TECHNOLOGY RESPONSIBILITY MATRIX. D. EQUIPMENT SCHEDULES MAY CONTAIN ADDITIONAL FURNISH OR INSTALL RESPONSIBILITY RECOMMENDATIONS. THESE SUPERSEDE RECOMMENDATIONS FOUND IN DETAIL ANNOTATIONS AND THE TECHNOLOGY RESPONSIBILITY MATRIX. E. CONTRACTOR IS RESPONSIBLE FOR FINAL DETERMINATION OF ALL COMPONENTS AND ASSOCIATED FURNISH AND INSTALL RESPONSIBILITIES REQUIRED FOR PROVISION OF COMPLETE TECHNOLOGY SYSTEMS READY FOR OWNER'S USE. DETERMINATION OF SUCH SHALL OCCUR PRIOR TO BID. F. DETERMINATION AND EXECUTION OF ALL NECESSARY COMPONENTS AND ASSOCIATED FURNISH AND INSTALL RESPONSIBILITIES SHALL CONFORM TO PROJECT SCHEDULE. G. CABLING FOR COMPONENTS SHALL BE PROVIDED BY ENTITY INSTALLING COMPONENT UNLESS OTHERWISE INDICATED. H. EACH TRADE SHALL COORDINATE ROUGH-IN REQUIREMENTS (INCLUDING SLEEVES) WITH ELECTRICAL CONTRACTOR PRIOR TO ROUGH-IN. I. DEVICES AND HORIZONTAL CABLING OF DEVICES (INCLUDING CABLE TERMINATIONS) WITHIN ASSEMBLIES (FLOOR BOXES, POKE-THROUGHS, TABLE TOP INTERFACES, WALL BOXES, FURNITURE FEEDS, UTILITY POLES, SURFACE RACEWAYS, ETC.) SHALL BE BY RESPECTIVE TRADES. 1. 2. MATRIX NOTES EACH RESPECTIVE TRADE SHALL COORDINATE EXTENT OF WORK WITH ELECTRICAL CONTRACTOR PRIOR TO ROUGH IN. EACH TRADE SHALL COORDINATE PROVISION OF THIS COMPONENT WITH TELECOMMUNICATIONS CONTRACTOR. TELECOMMUNICATIONS CONTRACTOR SHALL PROVIDE THIS COMPONENT UNLESS DETERMINED OTHERWISE IN CONJUNCTION WITH TELECOMMUNICATIONS CONTRACTOR. 4. FURNISHING CONTRACTOR TO PROVIDE ROUGH IN DIMENSIONS / TEMPLATE AND DESIRED LOCATION FOR TABLE TOP INTERFACE. INSTALLING CONTRACTOR SHALL CUT-OUT SURFACE OF TABLE, IDENTIFYING AND COORDINATING ANY POTENTIAL CONFLICTS WITH DESIRED LOCATION PRIOR TO PERFORMING ANY WORK. 5. EACH TRADE SHALL COORDINATE PROVISION OF THIS COMPONENT WITH GENERAL CONTRACTOR. GENERAL CONTRACTOR SHALL PROVIDE THIS COMPONENT UNLESS DETERMINED OTHERWISE IN CONJUNCTION WITH GENERAL CONTRACTOR. 7. ELECTRICAL CONTRACTOR SHALL COORDINATE EXTENT OF WORK WITH GENERAL CONTRACTOR. 9. AUDIOVISUAL CONTRACTOR SHALL COORDINATE EXTENT OF WORK WITH GENERAL CONTRACTOR. ABBREV. DEFINITION ABBREV. DEFINITION AC ACEG ACLGS ACP ACS ACT AFF AHJ AO AOC APC APP APPROX AR ARCH ATEL AV AVC AWG BAS BB BC BEP BI BLDG BO C CAB CAN CAT3 CAT5E CAT6 CAT6A CATV CC CCTV CER CLG CNL CO COAX COM COMM CON CPU CPV CR CT CV DB (D) DD DEA DGCB DIA DM DP DPDT DPS DS DVI DVR DWG (E) EB EC ECL ECP EF EIB EL ELEC ELM ELR ELV EMT ENCL EQPMT ER ES ESO EXIST (F) FAC FACP FB FD FL FLEX FPA FPD FS FSD G GC HB HC HD HDBT HDMI HO ID IDS IF IG IMC IP IR ISP IVW IWC KIT LAB LC LL LM LPS LR MAG MECH MED MFR MIC MIN ABOVE COUNTER ALTERNATING CURRENT ELECTRICAL GROUND ACCESSIBLE CEILING SPACE ACCESS CONTROL PANEL ACCESS CONTROL SYSTEM ACOUSTIC CEILING TILE ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION AUTOMATIC OPERATOR AUTOMATIC OPENER CONTROLLER ANGLE POLISHED CONNECTOR AUDIO PATCH PANEL APPROXIMATELY AUXILIARY RELAY ARCHITECT ADMINISTRATIVE TELEPHONE AUDIOVISUAL AUDIOVISUAL CONTRACTOR AMERICAN WIRE GAUGE BUILDING AUTOMATION SYSTEM BACKBONE BARE COPPER BUILDING ENTRANCE PROTECTOR BIOMETRIC INTERFACE BUILDING BY OTHERS CONDUIT CABINET CONTROLLED AREA NETWORK CATEGORY 3 COPPER CABLE CATEGORY 5E COPPER CABLE CATEGORY 6 COPPER CABLE CATEGORY 6 AUGMENTED COPPER CABLE CABLE TELEVISION CONTACT CLOSURE CLOSED CIRCUIT TELEVISION CYLINDER ELECTRIC RETRACTION CEILING COULD NOT LOCATE CONDUIT ONLY (NO CABLE) COAX CABLE COMMON COMMUNICATION CONDUCTOR COMPUTER PROCESSING UNIT COMPONENT VIDEO CARD READER COUNT COMPOSITE VIDEO DIRECT BURIAL DEMOLISH DEAD DELAYED EGRESS ALARM DATA-GRADE COPPER BACKBONE DIAMETER DIGITAL MULTIMEDIA (SIGNAL) DISPLAYPORT DOUBLE POLE DOUBLE THROW DOOR POSITION SWITCH DIGITAL SIGNAGE DIGITAL VIDEO INTERFACE DIGITAL VIDEO RECORDER DRAWING EXISTING TO REMAIN EXIT BUTTON ELECTRICAL CONTRACTOR ELECTRIC CYLINDER LOCK ELEVATOR CONTROL PANEL ENTRANCE FACILITY (DEMARC) EMERGENCY INFORMATION BOARD ELECTRIC LATCH ELECTRICAL ELECTRIC LATCH WITH LATCH MONITOR SWITCH ELECTRICAL LATCH RETRACTION ELEVATOR ELECTRICAL METALLIC TUBING ENCLOSURE EQUIPMENT EQUIPMENT ROOM ELECTRIC STRIKE ELECTRICAL SOLENOID EXISTING FUTURE FIRE ALARM CONTRACTOR FIRE ALARM CONTROL PANEL FIBER BACKBONE, FLOOR BOX FLOOR DISTRIBUTOR FLUSH FLEXIBLE CONDUIT FLOOR PENETRATION ASSEMBLY FLAT PANEL DISPLAY FURNITURE SUPPLIER FIRE STOP DEVICE GROUND GENERAL CONTRACTOR HANDICAP BUTTON HORIZONTAL CABLE HIGH DEFINITION HDBASET (AV SIGNALS OVER TP) HIGH DEFINITION MULTIMEDIA INTERFACE HOLD OPEN INSIDE DIAMETER OR IDENTIFIER INTRUSION DETECTION SYSTEM INTERFACE PLATE ISOLATED GROUND INTERMEDIATE METAL CONDUIT INTERNET PROTOCOL INFRARED INSIDE PLANT IN VARIANCE WITH IN-BUILDING WIRELESS CONTRACTOR KITCHEN EQUIPMENT LABORATORY EQUIPMENT LOW VOLTAGE/SPECIALITY CONTRACTOR LINE LEVEL LEFT CHANNEL AUDIO LINE LEVEL MONO AUDIO LOCK POWER SUPPLY LINE LEVEL RIGHT CHANNEL AUDIO MAGNETIC LOCK MECHANICAL MEDICAL EQUIPMENT MANUFACTURER MICROPHONE (CONNECTION) MINIMUM ML MM MREX MS (N) (NL) NA NACLGS NC NEC NO NS NTS NVR O OB OC OD OFCI OFOI OHM OPE OR ORI OSP OXY PA PDS POE PP PR PRJ PS PWR (RL) (RE) R REV REX RF RFG RI RM RMC RNC RS-232 S SATV SC SCC SCHED SCNS SCP SCPP SCPS SH SM SMR SMT SN SP SPEC SPKR SPR SR SRR STP SUS SV TB TBB TBD TC TCP TEL TGB TMGB TP TR TYP U UGND UON UPP UPS USB UTP VB VE VGA VGA+A VGCB VLAN VMS VOIP VSS VTC VW W WM WP WAP MONITORED LATCH MULTIMODE FIBER OPTIC CABLE MOTION REQUEST TO EXIT MONITORED STRIKE NEW NEW LOCATION NOT APPLICABLE NON ACCESSIBLE CEILING SPACE NORMALLY CLOSED CONTACT NATIONAL ELECTRIC CODE NORMALLY OPEN CONTACT NETWORK SWITCH NOT TO SCALE NETWORK VIDEO RECORDER OWNER OVERRIDE BUTTON ON CENTER OUTSIDE DIAMETER OWNER FURNISHED, CONTRACTOR INSTALLED OWNER FURNISHED, OWNER INSTALLED RESISTIVE NETWORK OWNER PROVIDED EQUIPMENT OPERATING ROOM OPERATING ROOM INTEGRATION OUTSIDE PLANT OXYGEN PUBLIC ADDRESS PROTECTIVE DISTRIBUTION SYSTEM POWER OVER ETHERNET PATCH PANEL(S) PAIR PROJECTOR POWER SUPPLY POWER REMOVE AND RELOCATE REMOVE RISER REVISION REQUEST TO EXIT SWITCH RADIO FREQUENCY RAISED FLOOR GROMMET READER INTERFACE ROOM RIGID METALLIC CONDUIT RIGID NONMETALLIC CONDUIT TWO WAY SERIAL DATA STREAM STATION SATELLITE TELEVISION SECURITY CONTRACTOR SECURITY CAMERA SCHEDULE SECURITY CAMERA NETWORK SWITCH SECURITY CONTROL PANEL SECURITY CAMERA PATCH PANEL SECURITY CAMERA POWER SUPPLY SURFACE HOUSING SINGLEMODE FIBER OPTIC CABLE SURFACE METAL RACEWAY SURFACE MOUNT SERIAL NETWORK MODULE SURGE PROTECTOR SPECIFICATION LOUDSPEAKER LEVEL AUDIO SURFACE PLASTIC RACEWAY SURFACE RACEWAY SERVER ROOM SHIELDED TWISTED PAIR SUSPENDED S-VIDEO TERMINATION BLOCK(S) TELECOMMUNICATIONS BONDING BACKBONE TO BE DETERMINED TELECOMMUNICATIONS CONTRACTOR TEMPERATURE CONTROL PANEL TELEPHONE TELECOMMUNICATIONS GROUNDING BUSBAR TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TWISTED PAIR TELECOMMUNICATIONS ROOM (IDF, FD) TYPICAL UNIT UNDERGROUND UNLESS OTHERWISE NOTED UNSHIELDED TWISTED PAIR PATCH PANEL UNINTERRUPTIBLE POWER SUPPLY UNIVERSAL SERIAL BUS UNSHIELDED TWISTED PAIR VOICE BACKBONE VOICE HD ANALOG VIDEO TYP 15 PIN D-SUB HD ANALOG VIDEO TYP 15 PIN D-SUB & 3.5MM TRS VOICE-GRADE COPPER BACKBONE VIRTUAL LOCAL AREA NETWORK VIDEO MANAGEMENT STATION VOICE OVER INTERNET PROTOCOL VIDEO SURVEILLANCE SYSTEM VIDEO TELE-CONFERENCING VIDEO WALL WALL TELEPHONE WALL MOUNTED WEATHER PROOF WIRELESS ACCESS POINT AUDIOVISUAL SYMBOL AE DESCRIPTION SYMBOL COMMON WORK / ELECTRICAL SHEET# TITLE DESCRIPTION T0.00 T0.01 T0.02 T2.01 T4.01 T4.02 T5.01 T5.02 TECHNOLOGY TITLE SHEET TECHNOLOGY PROJECT NOTES TECHNOLOGY SCHEDULES TECHNOLOGY PLAN - LEVEL 03 TECHNOLOGY SPACE PLANS TECHNOLOGY SPACE PLANS TECHNOLOGY DETAILS TECHNOLOGY DETAILS STRUCTURAL BLOCKOUT AUDIOVISUAL EQUIPMENT LOCATION WxH A LOUDSPEAKER FSD CABLE PATHWAY FIRESTOPPING DEVICE FPA FIRE-RATED FLOOR PENETRATION ASSEMBLY VIDEO DISPLAY PROJECTION SCREEN CP CONTROL PANEL IF INTERFACE PLATE GROUND CONDUIT WITH BUSHING CONDUIT WITH CAP PROJECTOR A FIXED CAMERA A PAN - TILT - ZOOM CAMERA CONDUIT UP CONDUIT DOWN CONDUIT / CABLE HOME RUN LECTERN SR A AUDIOVISUAL DEVICE A AUDIOVISUAL CEILING DEVICE A SURFACE RACEWAY CONDUIT UNDERGROUND / FLOOR / SLAB AUDIOVISUAL FIELD LOCATED DEVICE OSP OSP UNDERGROUND DUCTBANK P PULL BOX U UTILITY POLE CS CABLE SUPPORT PATHWAY (J-HOOKS / STRAPS / SLINGS) CT CABLE TRAY GROUNDING BUSBAR DRAWING ANNOTATIONS DEVICE BOX EMPTY SYMBOL DESCRIPTION DEVICE BOX EMPTY (CEILING) FLOOR BOX XX## OR # POKE THRU E ENCLOSURE KEYNOTE # DRAWING NOTE XX### OR (XX###) WALL BOX # EQUIPMENT RACK * EQUIPMENT SCHEDULE ID REVISION NUMBER ENLARGED FLOOR PLAN, SCHEDULE, OR DETAIL CALLOUT REFERENCE INDICATOR * # REFERENCE SHEET NUMBER # MAINTENANCE HOLE SECTION OR ELEVATION CALLOUT * # A D REFERENCE INDICATOR REFERENCE SHEET NUMBER * # ROOM WALL ELEVATION CALLOUT # A,B,C,D # B WALL ELEVATION REFERENCE REFERENCE SHEET NUMBER C BREAK LINE CONTINUANCE LINE X DETAIL FURNISH / INSTALL CALLOUT (ON DETAILS WHERE CALLOUTS ARE USED, ASSUME EC FOR X AND Y WHERE NOT INDICATED FOR COMPONENTS) UON IN TECHNOLOGY RESPONSIBILITY MATRIX) Y X INDICATES ENTITY (ABBREVIATED) RIMROCK RECOMMENDS BE RESPONSIBLE FOR FURNISHING Y INDICATES ENTITY (ABBREVIATED) RIMROCK RECOMMENDS BE RESPONSIBLE FOR INSTALLING TELECOM AREA BOUNDARY LINE COMMUNICATIONS TELECOM ROOM BOUNDARY LINE SYMBOL DESCRIPTION FUTURE EQUIPMENT, RACK, OR ENCLOSURE OUTLINE TE COMMUNICATIONS EQUIPMENT LOCATION SYMBOL CR TYPICAL WALL MOUNTED DEVICE NOTATION. EXAMPLE: CABLE RUNWAY A CEILING-MOUNTED SPEAKER A WALL-MOUNTED SPEAKER CABLE - END LOOP CABLE - CONTINUOUS LOOP TYPICAL POLE OR BOOM MOUNTED DEVICE NOTATION. EXAMPLE: SYMBOL TELECOM OUTLET TELECOM OUTLET (CEILING) T COMMUNICATIONS DEVICE T COMMUNICATIONS CEILING DEVICE T COMMUNICATIONS FIELD LOCATED DEVICE S WALL-MOUNTED SECURITY CAMERA S POLE-MOUNTED SECURITY CAMERA TYPICAL DEVICE OR EQUIPMENT NON-STANDARD HEIGHT (TELECOM OUTLET EXAMPLE SHOWN) +H H INDICATES DIMENSION OF DEVICE OR EQUIPMENT CENTERLINE (UON) ABOVE FINISHED FLOOR TYPICAL STATION CALLOUT XY X INDICATES NUMBER OF VOICE/DATA PORTS/CABLES Y INDICATES NUMBER OF COAX PORTS/CABLES (ASSUME 0 IF BLANK) AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 FURNISH NOTES APPLY TO ALL ENTITIES COLOMBINE HALL AUDIOVISUAL UPGRADES ENTITY COMPONENT SHEET LIST LEGEND UNIVERSITY OF COLORADO COLORADO SPRINGS TECHNOLOGY RESPONSIBILITY MATRIX TYPICAL ASSEMBLY NOTATION, INCLUDES: 2 - INFRASTRUCTURE: FLOOR BOX, POKE-THRU, WALL BOX, SURFACE RACEWAY, ENCLOSURE, HOUSING, RACK, ETC. IF - SERVICES: DEVICES AND/OR CABLING AS SHOWN ASSOCIATED WITH INFRASTRUCTURE. (FLOORBOX WITH INTERFACE PLATE AND TELECOM OUTLET EXAMPLE SHOWN). SYMBOL/DEVICE CONGESTION NOTATION INCLUDES: LEGEND NOTES ISSUE RECORD No 2 2. SUBSCRIPTS ADJACENT SYMBOLS ELSEWHERE ON DRAWINGS INDICATE ADDITIONAL INFORMATION REGARDING APPLICATION OF DEVICE OR EQUIPMENT. REFER TO ABBREVIATIONS, DRAWING ANNOTATIONS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL SYMBOL SUBSCRIPT INFORMATION. 3. MULTIPLE SUBSCRIPTS ADJACENT A SYMBOL SIGNIFY MULTIPLE DEVICE TYPES OR MULTIPLE INSTALLATION REQUIREMENTS FOR ONE OR MORE DEVICES. MULTIPLE SUBSCRIPTS REPRESENTING DIFFERENT DEVICE TYPES ADJACENT A SYMBOL IS EQUIVALENT TO MULTIPLE DEVICES LOCATED AT THE SAME OR APPROXIMATE PLAN LOCATION, BUT AT DIFFERENT ELEVATIONS. THE FIRST SUBSCRIPTS (STARTING FROM THE LEFT OR TOP) IS ASSOCIATED WITH THE DEVICE AT THE HIGHEST ELEVATION, THE SECOND SUBSCRIPT IS ASSOCIATED WITH THE DEVICE AT THE NEXT HIGHEST ELEVATION, ETC. Description Date LEADER INDICATOR: USED TO IDENTIFY INTENDED LOCATION OF SYMBOL(S) THAT WOULD OTHERWISE OVERLAP OR CREATE CONGESTION WITH OTHER SYMBOLOGY. 1. NOT ALL ITEMS LISTED IN THIS LEGEND ARE USED ON TECHNOLOGY DRAWINGS. A TARGET INDICATOR: USED TO IDENTIFY INTENDED LOCATION OF LEADER ARROWHEAD TERMINATION THAT WOULD OTHERWISE OVERLAP OR CREATE CONGESTION WITH OTHER SYMBOLOGY. A X WALL X CONGESTION INDICATOR: USED TO IDENTIFY ARRANGEMENT OF CONGESTED DEVICES. X INDICATES CONGESTION TYPE: H HORIZONTAL V VERTICAL (ALONG SAME STUD OR STUD CAVITY) B BOTH HORIZONTAL AND VERTICAL -- SINGLE ITEM (NOT ALIGNED) Client: RIMROCK CONTACTS Arvada Office 5420 Ward Road, Suite 200 Arvada, CO 80002 Phone: 303.422.7400 Colorado Springs Office 10807 New Allegiance Drive, Suite 400 Colorado Springs, CO, CO 80921 Phone: 719.533.1112 PROJECT MANAGER Andy Burkart 719.886.2459 andy.burkart@rimrockgroup.com CONSTRUCTION ADMINISTRATOR Andy Burkart 719.886.2459 andy.burkart@rimrockgroup.com UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: NONE TECHNOLOGY TITLE SHEET 100% CONSTRUCTION DOCUMENTS 10/23/2015 T0.00 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. GENERAL NOTES GENERAL AUDIOVISUAL A PROJECT NOTES INDICATE GENERAL REQUIREMENTS FOR WORK INDICATED ON THE DRAWINGS. APPLICABLE PROJECT NOTES SHALL BE CONSIDERED PART OF GENERAL NOTES FOR EACH SHEET. A PROJECT NOTES INDICATE GENERAL REQUIREMENTS FOR WORK INDICATED ON THE DRAWINGS. APPLICABLE PROJECT NOTES SHALL BE CONSIDERED PART OF GENERAL NOTES FOR EACH SHEET. B UNLESS OTHERWISE NOTED IN THE PROJECT NOTES, THE GENERAL REQUIREMENTS OF THE PROJECT NOTES SHALL GOVERN WORK INDICATED ON THE DRAWINGS, UNLESS SPECIFIC NOTATION ELSEWHERE ON THE DRAWINGS INDICATES DIFFERENT REQUIREMENTS, IN WHICH CASE THE DIFFERENT REQUIREMENTS INDICATED ELSEWHERE SHALL GOVERN. B REVIEW ALL NOTES FOR ALL TRADES TO ASSURE FULL COORDINATION BETWEEN ALL TRADES. C SPEAKER LOCATIONS SHOWN ARE APPROXIMATE. COORDINATE SPEAKER LOCATIONS WITH OTHER CEILING DEVICES. ENSURE THAT FINAL SPEAKER LOCATIONS MEET THE SOUND REINFORCEMENT INTENT FOR THE TARGET AREA. WORK SHALL COMPLY WITH THE GOVERNING REQUIREMENTS LISTED IN THE SPECIFICATIONS. E IF DISCREPANCIES OR CONFLICTS ARE DISCOVERED IN THE CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING AND WAIT FOR INSTRUCTION PRIOR TO PROCEEDING WITH WORK RELATED TO DISCREPANCIES OR CONFLICTS. F SUBSTITUTIONS OF PRODUCT AND DEVIATIONS FROM METHODS OF CONSTRUCTION SPECIFIED SHALL BE CONSIDERED AT SUBMITTAL REVIEW. SUCH SUBSTITUTIONS USED FOR BID SHALL BE AT THE SOLE RISK OF CONTRACTOR, AND AS SUCH ARE SUBJECT TO REJECTION WITHOUT CONSIDERATION. G RECORD DRAWINGS SHALL BE MAINTAINED ON SITE PER SPECIFICATIONS SHOWING ADDITIONS, CHANGES, DELETIONS THROUGHOUT CONSTRUCTION. H I PROVIDE SEISMIC BRACING AS REQUIRED BY THE GOVERNING REQUIREMENTS. DRAWING ELEMENTS SHOWN IN GRAY ARE TO BE INSTALLED AS PART OF A DIFFERENT BID PACKAGE OR PROVIDED BY OTHERS. WHERE SUCH ELEMENTS AFFECT THE CONTRACTORS WORK, COORDINATE DEPENDENCIES WITH APPLICABLE OTHERS IN A TIMELY MANNER, BEFORE SUCH DEPENDENCIES ARISE IN THE FIELD. J THIS PROJECT SHALL BE ACTIVELY MANAGED BY THE CONTRACTOR'S PROJECT MANAGER WHICH SHALL NOT ALSO BE THE CONTRACTOR'S FOREMAN OR BE INVOLVED IN TECHNICAL WORK IN THE FIELD. DOWNTIME, DELAYS OR NON-SCHEDULED OUTAGES DUE TO THE CONTRACTOR'S FAILURE TO ACTIVELY MANAGE THE WORK, INCLUDING BUT NOT LIMITED TO EFFECTIVELY PLANNING, SEQUENCING, SCHEDULING, AND EXECUTING THE WORK WILL NOT BE ACCEPTABLE AT ANY TIME. K WORK REQUIRING UTILITY AND/OR TECHNOLOGY SYSTEM OUTAGES SHALL BE COORDINATED WITH THE OWNER IN ADVANCE AND PRE-APPROVED IN WRITING. L COORDINATION IS REQUIRED PRIOR TO ROUGH-IN. DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED FOR BOX, DEVICE AND/OR EQUIPMENT LOCATIONS. LOCATIONS INDICATED ARE APPROXIMATE AND DO NOT REPRESENT THE ACTUAL FIELD CONDITION OR FINAL LOCATION. FURTHERMORE, REQUIREMENTS FOR ROUGH-IN BOXES, EQUIPMENT DIMENSIONS, MOUNTING/HEIGHTS, SUPPORTS, FACEPLATES, CONDUIT ROUTING, AND/OR INTERFACES MAY VARY. COORDINATE FINAL LOCATIONS AND REQUIREMENTS WITH ACTUAL FIELD CONDITIONS, SHOP DRAWINGS, RESPECTIVE TRADE(S), ARCHITECT, AND/OR OWNER PRIOR TO ROUGH-IN. M WHERE COORDINATION DICTATES THAT FINAL LOCATIONS VARY SIGNIFICANTLY FROM THAT SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND AWAIT APPROVAL PRIOR TO ELECTRICAL ROUGH-IN. N IDENTIFY AND COORDINATE WITH OTHER TRADES LOCATION AND SIZE OF REQUIRED OPENINGS IN NEW CONCRETE OR MASONRY PRIOR TO THE FORMING AND POURING OF CONCRETE OR CONSTRUCTION OF MASONRY. OPENINGS MAY NOT BE INDICATED ON DRAWINGS. O CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, OPENINGS, FASTENERS, CONNECTIONS, HANGERS, AND SUPPORTS WITH STRUCTURAL DRAWINGS AND ENGINEER PRIOR TO COMMENCEMENT OF WORK. WHEN LOCATING AND SIZING ALL PENETRATIONS THROUGH THE STRUCTURAL SLABS REFER TO THE STRUCTURAL DETAILS DEPICTING ALLOWABLE LOCATIONS AND OPENINGS. THE CONTRACTOR SHALL PREPARE A DRAWING(S) OF ALL PENETRATIONS AND COORDINATE THIS DRAWING(S) WITH THE GENERAL CONTRACTOR AND ALL OTHER TRADES TO VERIFY THAT THE LOCATIONS OF TECHNOLOGY REQUIRED PENETRATIONS DO NOT CONFLICT WITH PENETRATIONS REQUIRED BY ALL OTHER TRADES. P PENETRATION OF CONCRETE AND STRUCTURAL ELEMENTS SHALL BE AVOIDED WHERE POSSIBLE. OBTAIN WRITTEN APPROVAL FROM STRUCTURAL ENGINEER/ARCHITECT PRIOR TO SUCH NECESSARY PENETRATIONS. Q PROVIDE SLEEVES FOR LOCATIONS WHERE CABLE PASSES THROUGH WALLS, FLOORS, OR FOUNDATIONS. SLEEVES SHALL BE SIZED TO SUPPORT CABLES PER NEC FILL RATIOS AND TIA/EIA 569 CABLE CAPACITY STANDARDS PLUS <25 PERCENT> FUTURE EXPANSION. R PROVIDE CABLE PATHWAY FIRESTOPPING DEVICES FOR LOCATIONS WHERE CABLE WILL PENETRATE FIRE RATED BARRIERS. REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPE INFORMATION. PROVIDE CABLE PATHWAY FIRESTOPPING DEVICE(S) IN SUFFICIENT QUANTITY SUCH THAT THE COMBINED USEABLE CROSS SECTIONAL AREA OF THE DEVICE(S) MATCHES OR EXCEEDS THE CROSS SECTIONAL AREA OF CABLE TRAY TO BE SERVED. S FOR EACH CABLE PATHWAY FIRESTOPPING LOCATION SHOWN FEEDING CABLE TRAY, PROVIDE CABLE PATHWAY FIRESTOP DEVICE(S) IN SUFFICIENT QUANTITY SUCH THAT THE COMBINED USEABLE CROSS-SECTIONAL AREA OF THE DEVICE(S) IS GREATER THAN OR EQUAL TO THE CROSS-SECTIONAL AREA OF CABLE TRAY TO BE SERVED. FOR ALL OTHER FIRESTOP LOCATIONS, PROVIDE CABLE PATHWAY FIRESTOP DEVICE(S) IN SUFFICIENT QUANTITY SUCH THAT THE COMBINED USEABLE CROSS-SECTIONAL AREA OF THE DEVICE(S) IS GREATER THAN THE CROSS-SECTIONAL AREA OF ALL CABLES TO PASS THROUGH THE DEVICES, PLUS THE ADDITIONAL AMOUNT (PERCENTAGE) REQUIRED BY THE SPECIFICATIONS OR ELSEWHERE FOR FUTURE EXPANSION. T PER NEC REQUIREMENTS, TECHNOLOGY ITEMS SHALL NOT BE SECURED TO OR SUPPORTED BY SUSPENDED CEILING SYSTEM (INCLUDING SUPPORTS WIRES), HANGERS FOR CABLE SUPPORTS SHALL BE INDEPENDENT (DEDICATED). PER NEC REQUIREMENTS, WIRE HANGERS SHALL BE SUPPORTED AT BOTH ENDS AND DISTINGUISHABLE FROM SUSPENDED CEILING SYSTEM SUPPORT WIRE. IN EXPOSED STRUCTURAL CEILING SPACES, WIRE SHALL NOT BE USED AS A HANGER FOR SUPPORT. U HANGERS AND SUPPORTS SHALL BE PROVIDED AT INTERVALS PER THE NEC, SHALL BE ATTACHED TO STRUCTURE AND NOT BE ATTACHED TO OTHER BUILDING SYSTEMS AND THEIR ASSOCIATED SUPPORTS. CABLE SUPPORTS SHALL BE MOUNTED AT VARYING INTERVALS NOT TO EXCEED 5 FEET AND ROUTED PARALLEL AND PERPENDICULAR TO BUILDING LINES. CABLE SUPPORTS SHALL NOT SHARE CABLES OF DIFFERENT TECHNOLOGY SYSTEMS OR EXCEED 50 PERCENT OF THE MANUFACTURER'S RECOMMENDED FILL. INCLUDE CABLE SUPPORT ROUTING ON RECORD DRAWINGS. V CABLE DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR WITHIN 4 HOURS OF THE DAMAGING EVENT, AT NO ADDITIONAL COST TO THE OWNER. W COORDINATE WITH AUDIOVISUAL EQUIPMENT SUPPLIER AND SHOP DRAWINGS TO FINALIZE ALL STRUCTURAL SUPPORT REQUIREMENTS AND LOCATIONS FOR DISPLAYS, PROJECTORS AND PROJECTION SCREENS PRIOR TO ROUGH-IN. X SPEAKER LOCATIONS SHOWN ARE APPROXIMATE. COORDINATE SPEAKER LOCATIONS WITH OTHER CEILING DEVICES. ENSURE THAT FINAL SPEAKER LOCATIONS MEET THE SOUND REINFORCEMENT INTENT FOR THE TARGET AREA. COMMON WORK / ELECTRICAL A PROJECT NOTES INDICATE GENERAL REQUIREMENTS FOR WORK INDICATED ON THE DRAWINGS. APPLICABLE PROJECT NOTES SHALL BE CONSIDERED PART OF GENERAL NOTES FOR EACH SHEET. B EVERY CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE GENERAL NOTES - GENERAL SECTION FOR PROJECT NOTES THAT APPLY TO MORE THAN ONE TRADE AS WELL AS ALL OTHER NOTES PROVIDED FOR OTHER TRADES FOR FULL COORDINATION BETWEEN ALL TRADES. AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 D COLOMBINE HALL AUDIOVISUAL UPGRADES EXAMINE THE CONTRACT DOCUMENTS IN THEIR ENTIRETY, INCLUDING BUT NOT LIMITED TO GENERAL AND SUPPLEMENTAL REQUIREMENTS, DRAWINGS AND SPECIFICATIONS OF OTHER DIVISIONS, AND ADDENDA, FOR EQUIPMENT OR WORK WHICH MAY AFFECT WORK UNDER THIS SECTION, REGARDLESS OF WHETHER SUCH REQUIREMENTS OR WORK ARE SPECIFICALLY INDICATED IN THIS SECTION. UNIVERSITY OF COLORADO COLORADO SPRINGS C ISSUE RECORD No Description Client: Date UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: NONE TECHNOLOGY PROJECT NOTES 100% CONSTRUCTION DOCUMENTS 10/23/2015 T0.01 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. DETAIL INDEX ACCESSIBLE: EASY ACCESS. ACCESS ATTAINED WITHOUT REQUIRING EXTENSIVE REMOVAL OF OTHER MATERIALS TO GAIN ACCESS. B ACCESSIBLE CEILING: ACOUSTICAL TILE HANGING CEILINGS (“HARD-LID” CEILINGS (CONCEALED SPINE OR SHEETROCK/GYPSUM CEILINGS), EVEN WHEN PROVIDED WITH ACCESS PANELS, ARE NOT CONSIDERED AN ACCESSIBLE CEILING.) C BY OTHERS: A PARTY OR ENTITY OTHER THAN THE CONTRACTOR. THE CONTRACTOR SHALL ENGAGE THE GENERAL CONTRACTOR, ARCHITECT, AND/OR OWNER TO DETERMINE THIS PARTY OR ENTITY FOR CONSIDERATION OF PRICING AND/OR EXECUTION OF THE WORK. D COMMUNICATIONS (OR TECHNOLOGY) GROUNDING SYSTEM: INCLUDES (BUT IS NOT LIMITED TO) PROVIDING A PERMANENT GROUNDING AND BONDING INFRASTRUCTURE FOR THE COMMUNICATIONS CABLING SYSTEM. E ELECTRICAL FOR COMMUNICATIONS SYSTEMS ALSO REFERED TO AS COMMUNICATIONS (OR TECHNOLOGY) PATHWAY SYSTEM: INCLUDES (BUT IS NOT LIMITED TO) DEVICE BOXES, PULL BOXES, CONDUIT, CABLE TRAY, DUCT/DUCTBANK, AND OTHER PATHWAY AND RACEWAY COMPONENTS NECESSARY TO PROVIDE PATHWAY FOR, SUPPORT, AND ROUTE COMMUNICATIONS CABLES. F G H SHEET TA-CRS - CEILING RECESSED SCREEN DETAIL TA-CSD - CEILING SPEAKER DETAILS TA-IFB - BACK BOX DETAIL FOR AV WALL INTERFACE REQUIRING BACKING TA-IFER - BACK BOX DETAIL FOR AV EQUIPMENT RACK TA-IFW - BACK BOX DETAIL FOR AV WALL INTERFACE TA-PMD - PROJECTOR MOUNT DETAILS TA-TTIF - TABLE TOP INTERFACE DETAIL TA-VCW - BACK BOX DETAIL FOR AV DEVICE CONTROL T5.01 T5.01 T5.01 T5.01 T5.01 T5.02 T5.01 T5.01 AUDIOVISUAL SYMBOL AE A SUBSCRIPT AUDIOVISUAL EQUIPMENT LOCATION SHARED RACK SPACE (TYP TR) CONCEALED: HIDDEN FROM SIGHT IN INTERSTITIAL BUILDING SPACES, CHASES, FURRED SPACES, SHAFTS, CRAWL SPACES, ETC. STANDARD (WALL) TYPE A TYPE B TYPE C LOUDSPEAKER (CEILING) STANDARD ACT (REPLACEMENT OR CUT-IN) N NON-ACCESSIBLE CEILING P PENDANT S SUB-WOOFER DS VIDEO DISPLAY (CEILING) PLENUM ACT CEILING A ACT CEILING DS DIGITAL SIGNAGE E EXPOSED N NON-ACCESSIBLE CEILING K GOVERNING AUTHORITY: ENTITIES OR THEIR REPRESENTATIVES CHARGED WITH FORMATION AND/OR ENFORCEMENT OF GOVERNING REQUIREMENTS, SUCH AS THE AUTHORITY HAVING JURISDICTION (AJH). PROJECTION SCREEN STANDARD (WALL) L M INSTALL: TO PLACE IN FINAL POSITION IN FULLY OPERABLE, TESTED CONDITION. PROVIDE: TO FURNISH AND INSTALL, COMPLETE, TESTED AND READY FOR INTENDED USE. N ROUGH-IN: PROVIDE THE COMMUNICATIONS PATHWAY SYSTEM, INCLUDING (BUT NOT LIMITED TO) DEVICE BOXES, PULL BOXES, WALL BOXES, FLOOR BOXES, POKE-THROUGH DEVICES, CONDUIT, ENCLOSURES, CABLE TRAY, DUCTS/DUCTBANKS, MAINTENANCE HOLES, HAND HOLES, AND OTHER PATHWAYS AND ITEMS INDICATED (OR AS REQUIRED) FOR ROUTING, SUPPORTING, AND INSTALLING COMMUNICATIONS CABLES, DEVICES, OR EQUIPMENT WHICH SHALL BE PROVIDED BY OTHERS OR PROVIDED UNDER A SUBSEQUENT SET OF CONTRACT DOCUMENTS. PROJECTION SCREEN (CEILING) RECESSED C SUSPENDED CP PHASING SCHEDULE 317 3/21/16 THRU 3/27/16 322, 325 NOTES SCD 3/23/16 4PM 3 5/16/16 THRU 6/12/16 323, 324, 333 3A 5/16/16 THRU 5/21/16 334 SCD 5/18/16 4PM 3B 6/6/16 THRU 6/11/16 329 SCD 6/8/16 4PM DETAILS ID TA-IFWB FSD CABLE PATHWAY FIRESTOPPING DEVICE TE-WFS FS102 FPA FIRE-RATED FLOOR PENETRATION ASSEMBLY TE-FFS FS110 GROUND CONDUIT WITH BUSHING CONDUIT WITH CAP TA-CSD TA-CSD CONDUIT UP CONDUIT / CABLE HOME RUN SURFACE RACEWAY OSP TA-PMD TA-PMD TA-WMS CONTROL PANEL STANDARD (BACKBOX) A TYPE A T TABLE TOP / TOUCH PANEL INTERFACE PLATE STANDARD (WALL) B TYPE B C TYPE C F STANDARD, FLOOR T TABLE TOP / FURNITURE OSP UNDERGROUND DUCTBANK P PULL BOX U UTILITY POLE CS SHORT THROW (INTERACTIVE) SHORT THROW (PRESENTATION) TYPE B TA-CRS TA-CSS PROJECTOR (CEILING) PLENUM ACT CEILING A ACT CEILING E EXPOSED N NON-ACCESSIBLE CEILING 2) SIGNIFICANT COMPLETION DATE (SCD) SHALL BE 5 BUSINESS DAYS PRIOR TO END OF GIVEN PROJECT PHASE UNLESS OTHERWISE NOTED. PROJECTOR LIFT CEILING MOUNTED A FIXED CAMERA (CEILING) (NO SUBSCRIPT) A TYPE A A PAN - TILT - ZOOM CAMERA (NO SUBSCRIPT) A TYPE A A PAN - TILT - ZOOM CAMERA (CEILING) (NO SUBSCRIPT) A TYPE A CABLE TRAY (DEPTH x WIDTH) (NO SUBSCRIPT) TA-IFCP TA-IFCP TA-IFW DEVICE BOX EMPTY (NO SUBSCRIPT) AV AUDIOVISUAL TA-FIF TA-TIF FF S SEP TA-WPD FURNITURE FEED SECURITY SITE EMERGENCY PHONE DEVICE BOX EMPTY (CEILING) (NO SUBSCRIPT) AV AUDIOVISUAL TA-PMD TA-PMD TA-PMD TA-PMD S JS001 JS010 TE-BJ, TE-CT, TE-CTUB, TE-CR CT201 SECURITY GB020 GB010 TE-CR TE-CR, TA-DETAILS TE-CR TS-SD TE-CR TA-IFB TE-CR, TA-DETAILS TS-SD FLOOR BOX FB4 FB6 FB8 FB10 FBF TA-PL POKE THRU PT6 PT8 PTF TA-IFB TA-IFB E (NO SUBSCRIPT) 4-GANG 6-GANG 8-GANG 10-GANG FURNITURE FEED TE-FB TE-FB TE-FB TE-FB TE-FB TE-FB 6-INCH 8-INCH FURNITURE FEED CB001 CB004 CB006 CB008 CB010 CB015 CB023 CB025 ENCLOSURE S LECTERN AUDIOVISUAL CEILING BOX SECURITY CEILING ENCLOSURE TA-PE TS-SD WALL BOX (NO SUBSCRIPT) A TE-CR GROUNDING BUSBAR TGB GROUND BUS TMBG MAIN GROUND BUS NOTES: 1) CONFIRM ALL DATES WITH UCCS PROJECT MANAGEMENT. MH400 CABLE SUPPORT PATHWAY (NO SUBSCRIPT) J J-HOOKS PROJECTOR A B SR100 CONDUIT UNDERGROUND / FLOOR / SLAB TA-PMD TA-PMD CT-DxW IF 12/21/15 THRU 1/8/16 DESCRIPTION WxH TC SERIES SR EXPOSED: NOT CONCEALED AND NOT INSTALLED UNDERGROUND. FURNISH: TO PURCHASE, SUPPLY, AND DELIVER TO THE PROJECT MATERIALS IN NEW AND OPERABLE CONDITION, READY FOR INSTALLATION. 2 SUBSCRIPT STRUCTURAL BLOCKOUT (WIDTH x HEIGHT) STANDARD (WALL) DIGITAL SIGNAGE I J 1 SYMBOL VIDEO DISPLAY CONTRACT DOCUMENTS: THE AGREEMENT (INCLUDING OTHER DOCUMENTS LISTED IN THE AGREEMENT), CONDITIONS OF THE CONTRACT (GENERAL, SUPPLEMENTARY AND OTHER CONDITIONS), AND THE CONSTRUCTION DOCUMENTS. PHASE ID CONDUIT DOWN CONSTRUCTION DOCUMENTS: COLLECTIVE TERM FOR THE ENTIRE SET OF BOUND OR UNBOUND MATERIAL DESCRIBING THE CONSTRUCTION AND SERVICES REQUIRED, INCLUDING ALL DRAWINGS, SPECIFICATIONS, ADDENDA ISSUED PRIOR TO EXECUTION OF THE CONTRACT, AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT (SUCH AS CHANGE ORDERS, CONSTRUCTION CHANGE DIRECTIVES, SUPPLEMENTAL INSTRUCTIONS, ETC.). PROJECT PHASING SCHEDULE DATES ROOMS DETAILS LOUDSPEAKER A B C A DESCRIPTION COMMON WORK / ELECTRICAL VIDEO DISPLAY AUDIOVISUAL DEVICE ALS ASSISTIVE LISTENING AP WIRELESS ACCESS POINT TRANSCEIVER S SCREEN SWITCH VC VOLUME CONTROL WM WIRELESS MIC ANTENNA A AUDIOVISUAL CEILING DEVICE ALS ASSISTIVE LISTENING AP WIRELESS ACCESS POINT TRANSCEIVER M MICROPHONE WM WIRELESS MIC ANTENNA A AUDIOVISUAL FIELD LOCATED DEVICE DM DUAL-ELEMENT BOUNDARY MICROPHONE M MICROPHONE TM TRI-ELEMENT BOUNDARY MICROPHONE WC WEB CAM EQUIPMENT RACK AUDIOVISUAL (FLOOR) W AUDIOVISUAL (WALL) TA-DWB TA-IFER TA-IFWR HAND HOLE (NO SUBSCRIPT) MAINTENANCE HOLE (NO SUBSCRIPT) TE-MH, TE-MHCE MH100 DETAILS ID COMMUNICATIONS SYMBOL T E CR-X SUBSCRIPT DESCRIPTION COMMUNICATIONS EQUIPMENT LOCATION (NO SUBSCRIPT) CABLE RUNWAY (X INDICATES MINIMUM WIDTH IN INCHES) (NO SUBSCRIPT) TC-CR, TC-CRAD A ALTERNATE SPACING TC-CR, TC-CRAD ER200 ER201 AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 A DETAIL COLOMBINE HALL AUDIOVISUAL UPGRADES GENERAL DEVICE SCHEDULE UNIVERSITY OF COLORADO COLORADO SPRINGS TERMS AND DEFINITIONS CABLE - END LOOP (NO SUBSCRIPT) CABLE - CONTINUOUS LOOP (NO SUBSCRIPT) TELECOM OUTLET (NO SUBSCRIPT) AC ABOVE COUNTER AV AUDIOVISUAL DS E ELEC ELV EP F FACP K LCP MECH POS S SR VND W WAP DIGITAL SIGNAGE EMERGENCY INFORMATION BOARD ELECTRICAL EQUIPMENT ELEVATOR EQUIPMENT EMERGENCY BLUE PHONE FURNITURE MOUNTED FIRE ALARM CONTROL PANEL KIOSK LIGHTING CONTROL PANEL MECHANICAL/HVAC EQUIPMENT POINT OF SALE SECURITY CAMERA SURFACE RACEWAY VENDING MACHINE WALL TELEPHONE WIRELESS ACCESS POINT TELECOM OUTLET (CEILING) (NO SUBSCRIPT) AV AUDIOVISUAL DS E S WAP DIGITAL SIGNAGE EMERGENCY INFORMATION BOARD SECURITY CAMERA WIRELESS ACCESS POINT TE-CR TE-CR TE-CR, TA-DETAILS TE-CR, TA-DETAILS TE-CR ISSUE RECORD No Description Date TE-CR TE-CR TE-CR TE-CR TE-CR TE-CR TE-CR TE-CR TS-CD TE-CR TE-CR TE-CR TE-CR TE-CR, TA-DETAILS TE-CR, TA-DETAILS TE-CR Client: UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: NONE TS-CD TE-CR TECHNOLOGY SCHEDULES T COMMUNICATIONS DEVICE (NO SUBSCRIPT) T COMMUNICATIONS CEILING DEVICE (NO SUBSCRIPT) 100% CONSTRUCTION DOCUMENTS 10/23/2015 T COMMUNICATIONS FIELD LOCATED DEVICE (NO SUBSCRIPT) T0.02 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. DEMOLITION NOTES A ABANDON ALL EXISTING COPPER AND FIBER AUDIOVISUAL CABLING. PROVIDE STAINLESS STEEL BLANK COVER FOR OUTLET BOX AT LECTERN. REMOVE CABLING FROM EXISTING PROJECTOR POLE MOUNT AND AMX TELEVISION MANAGER AND LEAVE NEATLY COILED AT PROJECTOR LOCATION ABOVE CEILING. REMOVE AND RETURN AUDIO AMPLIFIER (LOCATED NEAR PROJECTOR ABOVE CEILING), CEILING SPEAKERS, AMX TELEVISION MANAGER, PROJECTOR, AND SCREEN TO OWNER. REUSE EXISTING PROJECTOR POLE AND PROJECTOR MOUNTING HARDWARE. REMOVE AND DISPOSE OF PODIUM. KEYNOTES 313 UP 314 316B 312B 312A 316 UNIVERSITY OF COLORADO COLORADO SPRINGS 316A 312 315 312C 312D 312E 312F 304 317 T-4.02 307 304A T4.02 DN 308 320 312H 303 318 1 312G 305 301 300A 302 UP 310 321 335 1 1 1 T4.01 T4.01 T4.01 1 T4.01 TE04 TE04 T-4.01 TE04 T-4.01 TE04 T-4.01 T-4.01 333 334 323 322 328 1 T4.01 325 324 T-4.01 T-4.01 TE04 331 329 1 AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 337 PROVIDE OUTLET BOXES FOR AUDIOVISUAL, TELECOMMUNICATIONS, AND ELECTRICAL SERVICES TO LECTERN AT THIS LOCATION. REFER TO DETAIL TA-IFER FOR RECOMMENDED LAYOUT AND ASSUMED TELECOMMUNICATION AND ELECTRICAL REQUIREMENTS TO BE CONFIRMED BY OWNER. REFER TO RISER DIAGRAM ON TECHNOLOGY SPACE PLAN FOR ADDITIONAL INFORMATION AND REQUIREMENTS FOR AUDIOVISUAL OUTLET BOXES. COLOMBINE HALL AUDIOVISUAL UPGRADES DN TE04 1 T4.01 T4.01 T-4.01 TE04 ISSUE RECORD 326 DN TE04 330 No 327 Description Date 338 Client: N 1 TECHNOLOGY PLAN - LEVEL 03 T2.01 8' 4' 0 1/8" = 1'-0" 8' UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: As indicated TECHNOLOGY PLAN LEVEL 03 100% CONSTRUCTION DOCUMENTS 10/23/2015 T2.01 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. GENERAL NOTES A TE03 TA02 REVIEW ALL CONTRACT DOCUMENTS FOR PROJECT REQUIREMENTS. TECHNOLOGY SPACE PLANS MAY NOT BE PROVIDED FOR ALL SYSTEMS AND ARE NOT EXHAUSTIVE. INFORMATION PROVIDED IS PROGRAMMATIC; SOME ANCILLARY EQUIPMENT MAY BE SHOWN HEREIN FOR CLARITY, BUT NOT ALL ANCILLARY EQUIPMENT IS SPECIFIED. PROVIDE ALL COMPONENTS NECESSARY FOR A FULLY FUNCTIONAL SYSTEM(S) READY FOR THE OWNERS USE. REQUIREMENTS FOR POWER, MOUNTING, CABLE MANAGEMENT, COOLING, AND OTHER MISCELLANEOUS COMPONENTS REQUIRED FOR A FULLY FUNCTIONING SYSTEM ARE ASSUMED AND SHALL BE PROVIDED BY THE CONTRACTOR. SA 1 W 6 TE05 A IF IF B TE03 PROVIDE EMPTY 4 11/16" DEVICE BOX WITH SINGLE GANG MUD RING AND BLANK COVER PLATE FOR FUTURE CAMERA INTERFACE ADJACENT TO SCREEN. LOCATE IMMEDIATELY ABOVE WRITING SURFACE APPROXIMATELY (7) SEVEN FEET (6) SIX INCHES AFF. LOCATE TO SIDE OF SCREEN NEAREST LECTERN APPROXIMATELY (1) ONE FOOT FROM EDGE OF SCREEN. TE05 AS ROOM LAYOUTS VARY, LOCATIONS SHALL BE REVIEWED AND CONFIRMED DURING THE MANDATORY CONSTRUCTION KICKOFF MEETING PRIOR TO PERFORMING ANY WORK. REFER TO RISER DIAGRAM ON TECHNOLOGY SPACE PLAN AND DETAIL TA-IFER FOR GENERAL INFORMATION AND REQUIREMENTS. THE TYPICAL ORDER OF OUTLET BOXES FROM FRONT TO BACK OF THE ROOM SHALL BE: SCREEN SWITCH, TELEPHONE OUTLET, DATA OUTLET, AV INTERFACE PLATES, THEN ELECTRICAL OUTLET. T4.01 A 2 TOUCHPANEL 7" * TSW-752 POE CC CC 16:10 ELECTRIC RECESSED SCREEN * 60" x 96" TENSIONED ADVANTAGE 113" DIAGONAL CC SCREEN SWITCH * AS REQUIRED TABLE STAND KIT FOR TSW-750 TSW-750-TTK-X-S TO NETWORK BY OTHERS POE SWITCH 5 PORT CEN-SW-POE-5 IP HDBT HDBT TO NETWORK BY OTHERS IP PROJECTOR * G6470WU IP TO NETWORK BY OTHERS VGA LL LR HDMI N 1 CLASSROOM ENLARGED FLOOR PLAN SMART LECTURN CABLE POCKET T4.01 4' 2' 0 1/4" = 1'-0" 4' MIC LM LM DETAIL AV-D1 SPKR 8 OHM DIGITALMEDIA PRESENTATION SYSTEM * DMPS3-4k-150-C CV LL LR ASSISTED LISTENING SYSTEM (OFOI) AUDIO AMPLIFIER * DCi 2 | 300 LM INTERFACE PLATE CUSTOM As Required HDMI DA & EXTRACTOR HDMI * HD-DA-2 WALL SURFACE LOUDSPEAKER * CDD5x HDMI TO NETWORK BY OTHERS IP COMPUTER (OFCI) USB TO NETWORK BY OTHERS IP TO NETWORK BY OTHERS IP DOCUMENT CAMERA * VZ-3 APPLE TV * APPLE TV HDMI HDMI SMART LECTERN MT-400-UCCS-MAPLE-NATURAL -7302 2 CLASSROOM PRESENTATION WALL ELEVATION 5 T4.01 CLASSROOM AUDIOVISUAL ONE-LINE DIAGRAM T4.01 4' 2' 0 1/4" = 1'-0" 4' CEILING AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 CENTER PROJECTOR SCREEN AND SPEAKER ON EXISTING PROJECTOR MOUNT LOCATION. AS ROOM LAYOUTS VARY, LOCATIONS SHALL BE REVIEWED AND CONFIRMED DURING THE MANDATORY CONSTRUCTION KICKOFF MEETING PRIOR TO PERFORMING ANY WORK. TYPICAL LOCATION SHALL BE APPROXIMATELY FIVE FEET FROM PRESENTATION WALL. USE CEILING MOUNT WITH TILE BRIDGE AND SAFETY CABLE AS REQUIRED. COLOMBINE HALL AUDIOVISUAL UPGRADES TA02 UNIVERSITY OF COLORADO COLORADO SPRINGS KEYNOTES 2 BASE BID: PROVIDE FLEX CONDUITS FOR NEW AV, TELECOM AND POWER OUTLETS +90" (2) 1-INCH CONDUITS ADD ALTERNATE #1 (2) 1-INCH CONDUITS A S +48" (2) 1 1/4-INCH CONDUITS PROVIDE HARD CONDUITS FOR NEW AV, TELECOM AND POWER OUTLETS ISSUE RECORD (2) 1 1/4-INCH CONDUITS No (REF. DETAIL TA-IFER) +18" IF FLOOR RISER GENERAL NOTES C. ADDITIONAL CONDUITS FOR TELECOMM OR POWER MAY BE REQUIRED. REFERENCE DEVICE DETAILS AND TELECOMM AND ELECTRICAL PLANS. RISER DRAWING NOTES 1. REFERENCE DETAIL TA-IFER FOR GENERAL LAYOUT INFORMATION AND ASSUMED ELECTRICAL AND TELECOMM REQUIREMENTS TO BE CONFIRMED BY OWNER. LOCATE OUTLET BOXES SERVING LECTERN LOCATION PER KEYNOTE ON TECHNOLOGY FLOOR PLANS. PROVIDE A BLANK PLATE FOR ONE OF THE BOXES TO BE LEFT AS SPARE FOR FUTURE USE. DESCRIPTION TYPE A A. ALL MEASUREMENTS ARE TO CENTER UNLESS OTHERWISE NOTED. B. STUB ALL CONDUITS TO ACCESSIBLE CEILING SPACE OF SAME ROOM UNLESS OTHERWISE ILLUSTRATED/NOTED IN RISER DIAGRAM. S MANUFACTURER PART NUMBER SPECIAL RQMTS 2 CHANNEL AUDIO AMPLIFIER CROWN DCi 2 | 300 WALL SURFACE LOUDSPEAKER MARTIN CDD5x DOCUMENT CAMERA WOLFVISION VZ-3 DIGITALMEDIA PRESENTATION SYSTEM CRESTRON DMPS3-4k-150-C HDMI DA & EXTRACTOR CRESTRON HD-DA-2 PROJECTOR EPSON G6470WU APPLE TV APPLE APPLE TV 16:10 ELECTRIC RECESSED SCREEN DA-LITE 60" x 96" TENSIONED ADVANTAGE 113" DIAGONAL SCREEN SWITCH DA-LITE AS REQUIRED TOUCHPANEL 7" CRESTRON TSW-752 TABLE STAND KIT FOR TSW-750 CRESTRON TSW-750-TTK-X-S POE SWITCH 5 PORT CRESTRON CEN-SW-POE-5 SMART LECTERN ATF MT-400-UCCS-MAPLE-NATURAL-7302 POWER CONDITIONER FURMAN P-8 PRO II INTERFACE PLATE CUSTOM RCI CUSTOM As Required SPEAKON NEUTRIK As Required ETHERCON CAT6A SHIELDED NEUTRIK As Required For Digital Media Net Connect Cable XG620 4pr 23 AWG CMP Yellow Jacket AMP 4-1499416-7 For Digital Media DISPLAY POLE MOUNTING HARDWARE CHIEF AS REQUIRED REUSE EXISTING PROJECTOR MOUNT CHIEF RPAU (5) REUSE EXISTING, (2) NEW MOUNTING BRACKET AS REQ. Client: AS REQUIRED T4.01 UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: 3 Date EQUIPMENT SCHEDULE +18" IF 1 Description As indicated CLASSROOM RISER DIAGRAM TECHNOLOGY SPACE PLANS 100% CONSTRUCTION DOCUMENTS 10/23/2015 T4.01 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. GENERAL NOTES A A A W TE02 B 1 6 IF IF IF TE02 REVIEW ALL CONTRACT DOCUMENTS FOR PROJECT REQUIREMENTS. TECHNOLOGY SPACE PLANS MAY NOT BE PROVIDED FOR ALL SYSTEMS AND ARE NOT EXHAUSTIVE. INFORMATION PROVIDED IS PROGRAMMATIC; SOME ANCILLARY EQUIPMENT MAY BE SHOWN HEREIN FOR CLARITY, BUT NOT ALL ANCILLARY EQUIPMENT IS SPECIFIED. PROVIDE ALL COMPONENTS NECESSARY FOR A FULLY FUNCTIONAL SYSTEM(S) READY FOR THE OWNERS USE. REQUIREMENTS FOR POWER, MOUNTING, CABLE MANAGEMENT, COOLING, AND OTHER MISCELLANEOUS COMPONENTS REQUIRED FOR A FULLY FUNCTIONING SYSTEM ARE ASSUMED AND SHALL BE PROVIDED BY THE CONTRACTOR. TE05 TE01 A TE03 KEYNOTES TA01 CENTER SPEAKER ON SCREEN AND LOCATE SPEAKER OUT OF LINE OF SIGHT FROM SEATED POSITION IN BACK ROW TO THE TOP OF PROJECTION SCREEN. TA03 PROJECTOR SCREEN AND SWITCH ARE EXISTING TO REMAIN. TE01 PROVIDE SPEAKER OUTLET BOXES WITH APPROPRIATE BACKING (AS REQUIRED) FOR CEILING SURFACE MOUNTED SPEAKERS. CENTER MIDDLE OUTLET BOX HORIZONTALLY ON SCREEN. LOCATE ALL THREE OUTLET BOXES (4) FOUR FEET FROM WEST (PRESENTATION) WALL. LOCATE LEFT AND RIGHT OUTLET BOXES (4) FOUR FEET FROM SIDE WALL. PROVIDE BACKING (AS REQUIRED) IMMEDIATELY ADJACENT TO BOX AND EXTEND EAST (TOWARD CENTER OF ROOM) AS FAR AS DRYWALL SLOPE CONTINUES, APPROXIMATELY (7) SEVEN FEET FROM WEST (PRESENTATION) WALL. TE02 LOCATE OUTLET BOX AS HIGH AS POSSIBLE ON WALL. COORDINATE LOCATION WITH AV CONTRACTOR PRIOR TO PERFORMING ANY WORK. TE03 PROVIDE EMPTY 4 11/16" DEVICE BOX WITH SINGLE GANG MUD RING AND BLANK COVER PLATE FOR FUTURE CAMERA INTERFACE ADJACENT TO SCREEN. LOCATE IMMEDIATELY ABOVE WRITING SURFACE APPROXIMATELY (7) SEVEN FEET (6) SIX INCHES AFF. LOCATE TO SIDE OF SCREEN NEAREST LECTERN APPROXIMATELY (1) ONE FOOT FROM EDGE OF SCREEN. TE05 AS ROOM LAYOUTS VARY, LOCATIONS SHALL BE REVIEWED AND CONFIRMED DURING THE MANDATORY CONSTRUCTION KICKOFF MEETING PRIOR TO PERFORMING ANY WORK. REFER TO RISER DIAGRAM ON TECHNOLOGY SPACE PLAN AND DETAIL TA-IFER FOR GENERAL INFORMATION AND REQUIREMENTS. THE TYPICAL ORDER OF OUTLET BOXES FROM FRONT TO BACK OF THE ROOM SHALL BE: SCREEN SWITCH, TELEPHONE OUTLET, DATA OUTLET, AV INTERFACE PLATES, THEN ELECTRICAL OUTLET. S A T4.02 A 2 TE01 TE01 A TE02 S TA03 A A TE02 A TOUCHPANEL 7" * TSW-752 N 1 POE CC CC FILM SCREENING CLASSROOM ENLARGED FLOOR PLAN TABLE STAND KIT FOR TSW-750 TSW-750-TTK-X-S T4.02 4' 2' 0 1/4" = 1'-0" 4' CC (EXISTING) TO NETWORK BY OTHERS IP SCREEN SWITCH * AS REQUIRED (EXISTING) POE SWITCH 5 PORT CEN-SW-POE-5 HDBT HDBT TO NETWORK BY OTHERS 16:10 ELECTRIC RECESSED SCREEN * 57.5" x 92" TENSIONED ADVANTAGE 109" DIAGONAL IP PROJECTOR * G6470WU IP TO NETWORK BY OTHERS VGA LL LR HDMI SMART LECTURN CABLE POCKET SPKR 8 OHM TA01 CV LL LR MIC ASSISTED LISTENING SYSTEM (OFOI) LM (FROM HD-XSP) LM DETAIL AV-D1 DIGITALMEDIA PRESENTATION SYSTEM * DMPS3-4k-150-C HDMI SURROUND SOUND PROCESSOR * HD-XSP LM (QTY. 8) 8 CHANNEL AUDIO AMPLIFIER * DCi 8 | 300 L/R/C & SURROUND (QTY. 7) HDMI TO NETWORK BY OTHERS IP WALL SURFACE LOUDSPEAKER * CDD5x SPKR COMPUTER (OFCI) 8 OHM USB TO NETWORK BY OTHERS DOCUMENT CAMERA * VZ-3 IP INTERFACE PLATE CUSTOM As Required HDMI CEILING SUBWOOFER * CONTROL 312CS CEILING SUB WOOFER BACKBOX MTC-300BB12 CEILING SUB WOOFER GRILLE MTC-300SG12 RS232 2 BLU-RAY PLAYER * DN-500BD FILM SCREENING CLASSROOM PRESENTATION WALL ELEVATION T4.02 4' 2' 0 1/4" = 1'-0" HDMI 4' HDMI SWITCHER 4K * HD-MD4X1-4K-3 HDMI HDMI TO NETWORK BY OTHERS IP IP APPLE TV * APPLE TV CEILING (1) 3/4-INCH CONDUIT A (1) 3/4-INCH CONDUIT A 1 +90" SMART LECTERN MT-400-UCCS-MAPLE-NATURAL -7302 BASE BID: PROVIDE FLEX CONDUITS FOR NEW AV, TELECOM AND POWER OUTLETS 4 (2) 1-INCH CONDUITS AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 2 A COLOMBINE HALL AUDIOVISUAL UPGRADES TA03 UNIVERSITY OF COLORADO COLORADO SPRINGS TA01 FILM SCREENING CLASSROOM ONE-LINE DIAGRAM T4.02 (2) 1 1/4-INCH CONDUITS ADD ALTERNATE #1 PROVIDE HARD CONDUITS FOR NEW AV, TELECOM AND POWER OUTLETS (2) 1 1/4-INCH CONDUITS (2) 1 1/4-INCH CONDUITS (REF. DETAIL TA-IFER) +18" IF FLOOR +18" IF +18" IF ISSUE RECORD 2 No Description Date EQUIPMENT SCHEDULE DESCRIPTION TYPE RISER GENERAL NOTES A. ALL MEASUREMENTS ARE TO CENTER UNLESS OTHERWISE NOTED. S B. STUB ALL CONDUITS TO ACCESSIBLE CEILING SPACE OF SAME ROOM UNLESS OTHERWISE ILLUSTRATED/NOTED IN RISER DIAGRAM. C. ADDITIONAL CONDUITS FOR TELECOMM OR POWER MAY BE REQUIRED. REFERENCE DEVICE DETAILS AND TELECOMM AND ELECTRICAL PLANS. RISER DRAWING NOTES 1. REFER TO ENLARGED FLOOR PLAN AND RELEVENT KEYNOTES FOR SPEAKER OUTLET BOX QUANTITY AND LOCATION INFORMATION. AUDIOVISUAL CONTRACTOR SHALL REVIEW SPEAKER MOUNTING BRACKET AND WIRE MANAGEMENT AND COORDINATE EXACT REQUIREMENTS WITH OWNER. 2. REFERENCE DETAIL TA-IFER FOR GENERAL LAYOUT INFORMATION AND ASSUMED ELECTRICAL AND TELECOMM REQUIREMENTS TO BE CONFIRMED BY OWNER. PROVIDE A BLANK PLATE FOR ONE OF THE BOXES TO BE LEFT AS SPARE FOR FUTURE USE. 3 T4.02 FILM SCREENING CLASSROOM RISER DIAGRAM A MANUFACTURER PART NUMBER SURROUND SOUND PROCESSOR CRESTRON HD-XSP 8 CHANNEL AUDIO AMPLIFIER CROWN DCi 8 | 300 CEILING SUBWOOFER JBL CONTROL 312CS CEILING SUB WOOFER - BACKBOX JBL MTC-300BB12 CEILING SUB WOOFER - GRILLE JBL MTC-300SG12 WALL SURFACE LOUDSPEAKER MARTIN CDD5x DOCUMENT CAMERA WOLFVISION VZ-3 BLU-RAY PLAYER DENON DN-500BD HDMI SWITCHER - 4K CRESTRON HD-MD4X1-4K-3 DIGITALMEDIA PRESENTATION SYSTEM CRESTRON DMPS3-4k-150-C PROJECTOR EPSON G6470WU APPLE TV APPLE APPLE TV TOUCHPANEL 7" CRESTRON TSW-752 TABLE STAND KIT FOR TSW-750 CRESTRON TSW-750-TTK-X-S POE SWITCH 5 PORT CRESTRON CEN-SW-POE-5 SPECIAL RQMTS MOUNTING BRACKET AS REQ. Client: SMART LECTERN ATF MT-400-UCCS-MAPLE-NATURAL-7302 POWER CONDITIONER FURMAN P-8 PRO II INTERFACE PLATE CUSTOM RCI CUSTOM As Required SPEAKON NEUTRIK As Required ETHERCON CAT6A SHIELDED NEUTRIK As Required For Digital Media Net Connect Cable XG620 4pr 23 AWG CMP Yellow Jacket AMP 4-1499416-7 For Digital Media DISPLAY POLE MOUNTING HARDWARE CHIEF AS REQUIRED REUSE EXISTING PROJECTOR MOUNT CHIEF RPAU REUSE EXISTING AS REQUIRED UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: As indicated TECHNOLOGY SPACE PLANS 100% CONSTRUCTION DOCUMENTS 10/23/2015 T4.02 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. BASE BID: PROVIDE FLEX CONDUITS FOR NEW AV, TELECOM AND POWER OUTLETS ADD ALTERNATE #1 PROVIDE HARD CONDUITS FOR NEW AV, TELECOM AND POWER OUTLETS INSULATED THROAT BUSHING INSULATED THROAT BUSHING AV CABLING STUB CONDUIT 6-INCHES INTO ACCESSIBLE CEILING UNLESS OTHERWISE NOTED INSULATED THROAT BUSHING AV CABLING AVC AVC AVC AVC BEND RADIUS = 6 x INTERNAL DIAMETER BEND RADIUS = 6 x INTERNAL DIAMETER BEND RADIUS = 6 x INTERNAL DIAMETER CEILING LEVEL (REF: ARCHITECTURAL) STUB CONDUIT 6-INCHES INTO ACCESSIBLE CEILING UNLESS OTHERWISE NOTED STUB CONDUIT 6-INCHES INTO ACCESSIBLE CEILING UNLESS OTHERWISE NOTED CEILING LEVEL (REF: ARCHITECTURAL) CEILING LEVEL (REF: ARCHITECTURAL) WALL (REF: ARCHITECTURAL) WALL (REF: ARCHITECTURAL) # TELECOM OUTLET BOX 4 11/16 - INCH SQUARE MIN 2 1/8 - INCH DEEP BOX FRAMING MUDRING (REF: TABLE FOR SIZE) FRAMING (REF: ARCHITECTURAL) AV OUTLET BOX 4 11/16 - INCH SQUARE MIN 2 1/8 - INCH DEEP BOX FLOOR (REF: ARCHITECTURAL) SEE AV RISER DIAGRAM TELECOM OUTLET BOX 4 11/16 - INCH SQUARE MIN 2 1/8 - INCH DEEP BOX SEE AV RISER DIAGRAM TYPE BOX MUDRING -- 2 2 A 2 1 -- -- -- BACK BOX DETAIL FOR AV WALL INTERFACE REQUIRING BACKING A SCALE: NONE FLOOR (REF: ARCHITECTURAL) MATCH TO LIGHT SWITCH MOUNTING HEIGHT 2 GANG MUDRING GANG SIZE TA-IFB # FLOOR (REF: ARCHITECTURAL) 16" O.C. TYP. DUPLEX POWER RECEPTACLE (REF: ELECTRICAL) AV OUTLET BOX 4 11/16 - INCH SQUARE MIN 2 1/8 - INCH DEEP BOX 16" O.C. TYP. SEE AV RISER DIAGRAM DETAIL GENERAL NOTES 1 GANG MUDRING A A TA-IFW BACK BOX DETAIL FOR AV WALL INTERFACE IF SCALE: NONE TA-IFER 2 GANG MUDRING A. LOCATIONS SHALL BE REVIEWED AND CONFIRMED DURING THE MANDATORY CONSTRUCTION KICKOFF MEETING. REFER TO RISER DIAGRAM AND TECHNOLOGY FLOOR PLAN FOR ADDITIONAL INFORMATION AND REQUIREMENTS. BACK BOX DETAIL FOR AV LECTERN LOCATIONS SCALE: NONE CONDUIT EC EC TO STRUCTURE INSULATED THROAT BUSHING HANGER WIRE TILE BRIDGE AVC AVC LOUDSPEAKER CABLE LOUDSPEAKER CUTOUT AREA AVC AVC 4" x 4" ELECTRICAL BOX AVC AVC AIRCRAFT CABLE TO STRUCTURE EC EC BEND RADIUS = 6 x INTERNAL DIAMETER AVC AVC LOUDSPEAKER CABLE TRIM RING AVC AVC AVC AVC AV CABLING STUB CONDUIT 6-INCHES INTO ACCESSIBLE CEILING UNLESS OTHERWISE NOTED CEILING LEVEL (REF: ARCHITECTURAL) LOUDSPEAKER CUTOUT AREA EXTRON AAP SCHEDULE Qty 1 1 1 1 TA-TTIF Part # Model Name 60-300-02 70-103-18 60-1346-02 70-092-72 AAP 102 One XLR 3-pin Male to Solder Cups, One XLR 3-pin Female to Solder Cups - Neutrik USB PowerPlate 200 AAP (Single-space) Three RCA Female to Solder Cup (Silkscreen) LOUDSPEAKER ACCESSIBLE CEILING (REF: ARCHITECTURAL) AVC AVC TABLE TOP INTERFACE DETAIL LOUDSPEAKER AVC AVC NON-ACCESSIBLE CEILING (REF: ARCHITECTURAL) WALL (REF: ARCHITECTURAL) N A A ACCESSIBLE CEILING NON-ACCESSIBLE CEILING AV OUTLET BOX 4 11/16 - INCH SQUARE MIN 2 1/8 - INCH DEEP BOX IF T SCALE: NONE ATTACH TO STRUCTURE THREADED ROD UNISTRUT STRUCTURAL SUPPORT ONE FOOT LONGER THAN CASE CEILING FAN TYPE DEVICE BOX THREADED ROD CONDUIT 1 GANG MUDRING EC EC CONNECT POWER TO SCREEN OR LOW VOLTAGE CONTROLLER AS REQUIRED (REF: ELECTRICAL) MOUNT TO UNISTRUT SUPPORT AVC AVC CEILING (REF: ARCHITECTURAL) LOUDSPEAKER CABLE AVC AVC FACEPLATE AIRCRAFT CABLE AVC AVC FORGED EYE BOLT AVC AVC CEILING (REF: ARCHITECTURAL) CEILING RECESSED SCREEN DTL. SCALE: NONE DETAIL GENERAL NOTES MATCH TO LIGHT SWITCH MOUNTING HEIGHT A. LOCATE ELECTRICAL BOX AND CONDUIT OUTSIDE OF LOUDSPEAKER CUTOUT AREA. COORDINATE WITH AUDIO VISUAL CONTRACTOR PRIOR TO CONDUIT INSTALLATION. AVC AVC SCREEN BOTTOM OF VIEWABLE AREA SHALL BE 48" AFF UON. PROVIDE EXTRA DROP AS REQUIRED. B. MOUNT EYE BOLT ONTO CUSTOM MANUFACTURED DEVICE BOX FACEPLATE. FACEPLATE MADE OF 1/8-INCH ALUMINUM WITH 1/2-INCH PASS THRU HOLE FOR CABLE SET OFF CENTER. ISSUE RECORD LOUDSPEAKER A AVC AVC AVC AVC TA-CRS FLOOR (REF: ARCHITECTURAL) AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 WALL (REF: ARCHITECTURAL) GC GC UNIVERSITY OF COLORADO COLORADO SPRINGS BACKING BOARD COLOMBINE HALL AUDIOVISUAL UPGRADES AV OUTLET BOX MIN 2 1/8 - INCH DEEP BOX P PENDANT CEILING TA-CSD CEILING SPEAKER DETAILS SCALE: NONE C. UTILIZE THEATER GRADE RIGGING HARDWARE INCLUDING BUT NOT LIMITED TO: AIRCRAFT CABLE, CABLE CLIPS, CABLE THIMBLES AND EYE BOLTS. A A N A No P TA-VCW BACK BOX DETAIL FOR AV DEVICE CONTROL SCALE: NONE A S Description Date A VC Client: UCCS Project #: 81515004 Designed By: RIMROCK Drawn By: RIMROCK Approved By: RIMROCK Scale: As indicated TECHNOLOGY DETAILS 100% CONSTRUCTION DOCUMENTS 10/23/2015 T5.01 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent. 1 ATTACH TO STRUCTURE PLENUM ENCLOSURE (REF AV TECHNOLOGY PLANS) EC EC AVC AVC ATTACH TO STRUCTURE ATTACH TO STRUCTURE THREADED ROD EDGE-PROTECTED BUNDLED CABLE INLET CAVITY ON EACH SIDE OF BOX, FILLED WITH FLAME RETARDANT FOAM SEAL KNOCKOUT # FOR TELECOM ATTACH TO STRUCTURE AV CABLING ATTACH TO STRUCTURE DUPLEX POWER RECEPTACLE (REF: ELECTRICAL) C. USE RIGID CONDUIT FOR ALL OUTLET BOXES. D. MOUNT PROJECTOR IN SUCH A WAY AS NOT TO BE OBSTRUCTED BY LIGHT FIXTURES, SPRINKLER HEADS, ETC. POLE MOUNT UNI-STRUT STRUCTURAL SUPPORT FRAME AVC AVC POLE MOUNT UNI-STRUT STRUCTURAL SUPPORT FRAME AVC AVC UNI-STRUT STRUCTURAL SUPPORT FRAME AV CABLING AVC AVC TELECOM OUTLET BOX 4 11/16 - INCH SQUARE # 1 GANG MUD RING MIN 2 1/8 - INCH DEEP BOX POLE MOUNT CEILING TILE (REF: ARCHITECTURAL) DUPLEX POWER RECEPTACLE (REF: ELECTRICAL) CEILING GRID (REF: ARCHITECTURAL) DUPLEX POWER RECEPTACLE (REF: ELECTRICAL) FIXED CEILING (REF: ARCHITECTURAL) TELECOM OUTLET BOX 4 11/16 - INCH SQUARE # 1 GANG MUD RING MIN 2 1/8 - INCH DEEP BOX CEILING TILE (REF: ARCHITECTURAL) ESCUTCHEON RING POLE ESCUTCHEON RING TELECOM OUTLET BOX 4 11/16 - INCH SQUARE # 1 GANG MUD RING MIN 2 1/8 - INCH DEEP BOX AVC AVC AVC AVC POLE PROJECTOR MOUNT AVC AVC AVC AVC PROJECTOR B. COORDINATE WITH ARCHITECT AND AUDIOVISUAL CONTRACTOR FOR PROJECTOR PLACEMENT PRIOR TO INSTALLING PROJECTOR STRUCTURAL SUPPORT. THREADED ROD CEILING GRID (REF: ARCHITECTURAL) POWER (REF: ELECTRICAL) ATTACH TO STRUCTURE FRONT VIEW AVC AVC # AVC AVC AV OUTLET BOX 4 11/16 - INCH SQUARE 2 GANG MUD RING MIN 2 1/8 - INCH DEEP BOX POLE FRONT VIEW # A FRONT VIEW PROJECTOR MOUNT NOT SHOWN N F. MOUNT PROJECTOR AS CLOSE TO THE CEILING AS POSSIBLE. REFER TO GENERAL NOTES D AND E AND ARCHITECTURAL DRAWINGS. DETAIL DRAWING NOTES 1. REUSE EXISTING PROJECTOR MOUNTING STRUCTURE. PROVIDE NEW TELECOM OUTLET BOX. # NON-ACCESSIBLE CEILING ACCESSIBLE CEILING AV OUTLET BOX 4 11/16 - INCH SQUARE 2 GANG MUD RING MIN 2 1/8 - INCH DEEP BOX POLE AVC AVC AVC AVC PROJECTOR MOUNT NOT SHOWN AVC AVC E. DIGITAL KEYSTONE CORRECTION SHALL NOT BE USED. PROJECTOR SHALL BE LOCATED AND ADJUSTED FIRST BY MOUNT THEN BY OPTICAL ADJUSTMENT(S) SO THE IMAGE IS FREE OF ANY KEYSTONING OR OTHER DISTORTION AND FILLS PROJECTION SCREEN/AREA. PROJECTOR MOUNT NOT SHOWN E EXPOSED CEILING FRONT VIEW CEILING PLATE # AVC AVC PLENUM CEILING BOTTOM VIEW TA-PMD PROJECTOR MOUNT DETAILS SCALE: NONE SCREEN BOTTOM VIEW SCREEN BOTTOM VIEW SCREEN # # A # N # E AUSTIN BLUFFS PKWY, COLORADO SPRINGS, CO 80918 THREADED ROD MOUNTING KIT THREADED ROD A. UNI-STRUT FRAMEWORK SHOULD BE PROVIDED TO ALLOW PROJECTOR TO BE MOUNTED ANYWHERE IN FRONT HALF OF THROW RANGE OF SPECIFIED PROJECTOR AND LENS. COLOMBINE HALL AUDIOVISUAL UPGRADES THREADED ROD DETAIL GENERAL NOTES ATTACH TO STRUCTURE UNIVERSITY OF COLORADO COLORADO SPRINGS ATTACH TO STRUCTURE ISSUE RECORD No Description Client: Project #: Designed By: Drawn By: Approved By: Scale: Date UCCS 81515004 Designer Author Approver NONE TECHNOLOGY DETAILS 100% CONSTRUCTION DOCUMENTS 10/23/2015 T5.02 © Copyright BCER Engineering Inc. Copyright reserved. All parts of this drawing are the exclusive property of BCER Engineering and shall not be used or reproduced in any manner without express written consent.