FTA902, 903, 952, 953 Separately Mounted Power Transfer Switch Model Number Selection Guide SEPARATELY MOUNTED FIRE PUMP POWER TRANSFER SWITCH FTA902, 903, 952, 953 (Ex..FTA902-AL100B-75HP-E) FTA ___ -A___ ___ ___ - ___HP-___ Options and Modifications (See Back) Transfer Switch Type 902 - Separately Mounted for generator alternate source. Required disconnecting means and overcurrent protective devices for normal (utility) source supplied by others. 903 - Separately mounted for generator alternate source. Required disconnecting means and overcurrent protective devices for normal (utility) source are supplied and integrally installed by Firetrol. 952 - Separately mounted for second utility alternate source. Required disconnecting means and overcurrent protective devices for normal (utility) source supplied by others. 953 - Separately mounted for second utility alternate source. Required disconnecting means and overcurrent protective devices for normal (utility) source are supplied and integrally installed by Firetrol. See Back Page Fire Pump Horsepower Rating 03 05 07(7.5) 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 Three Phase Operating Voltage A = 220-240V, 60Hz (230V) AZ = 220-240V, 50Hz B = 440-480V, 60Hz (460V) BZ = 415V, 50Hz C = 550-600V, 60Hz (575V) F = 380V, 60Hz FZ = 380V, 50Hz H = 208V, 60Hz HH = 200V, 60Hz Transfer Switch Single Motor Continuous Current Rating* 100 = 100A 150 = 150A 260 = 260A 400 = 400A 600 = 600A 800 = 800A 1000 = 1000A *Sized based on motor FLA x 1.15 Type 902 903 952 953 Code L M N P Q R M N P Q R M N P Q R Short Circuit Rating Normal Alternate See Table 1 L M N P Q R See Table 1 See Table 1 See Table 1 See Table 1 See Table 1 M N P Q R Table 1 Transfer Switch Rating Amps 100, 150 260, 400 600, 800 L L L L L M N P Q R M N P Q R Generator Service L - Standard short circuit rating 100-150A Transfer Switch 22,000A RMS Sym., 200-480V 250-400A Transfer Switch 35,000A RMS Sym., 200-480V 600-800A Transfer Switch 50,000A RMS Sym., 200-480V 100-800A Transfer Switch 10,000A RMS Sym., 550-600V Utility Service M - Standard short circuit rating 100,000A RMS Sym., 200-600V N - Intermediate short circuit rating 150,000A RMS Sym., 200-600V P - High short circuit rating 200,000A RMS Sym., 200-480V Q - Standard Intermediate short circuit rating 65,000A RMS Sym., 200-480V R - Standard Low short circuit rating 42,000A RMS Sym., 550-600V UL1008 Withstand and Close-On Ratings @ 480VAC “Any” Breaker Current-Limiting Max. Fuse Size Specific Breaker Rating ** Fuse Rating Rating ** Amps Types 200,000 ** J, L 22,000 10,000 200,000 ** J, L 42,000 35,000 200,000 ** J, L 65,000 50,000 ** Overcurrent protection must be selected by fuses (or set by circuit breakers) to indefinitely carry the lockedrotor current of the fire pump motor per NFPA20, NPFA70 and UL218. For more information on transfer switch withstand and close-on ratings, see ASCO publication 1128. Options and Modifications Special Enclosures -T NEMA Type 3R (IEC IP22), Painted Steel -E NEMA Type 4 (IEC IP66), Painted Steel -F NEMA Type 4X (IEC IP66), #304 Stainless Steel, Natural Finish** -FXP NEMA Type 4X (IEC IP66), #304 Stainless Steel, Painted Finish -FD NEMA Type 4X (IEC IP66), #316 Stainless Steel,Natural Finish** -FDB NEMA Type 4X (IEC IP66), 12 Gauge, Seam Welded, #316 Stainless Steel, Polished and Brushed Finish -FDP NEMA Type 4X (IEC IP66), #316 Stainless Steel Painted Finish -G NEMA Type 12 (IEC IP54), Painted Steel ** Natural Finish (Not painted, polished, or brushed). Anti-Condensation Space Heaters -H 120 Volt Space Heater -J 120 Volt Space Heater with Thermostat -K 120 Volt Space Heater with Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater with Thermostat -N 240 Volt Space Heater with Humidistat Miscellaneous -EC Extra contacts for remote indication, transfer switch position -S Tropicalization Emerson Network Power - Global Headquarters 1050 Dearborn Drive Columbus, OH 43085 Tel +1 614 888 0246 ASCO Power Technologies - Firetrol Brand Products 111 Corning Road, Suite 120 Cary, NC 27518 Tel +1 1 460 5200 FaY +1 1 460 5250 EmersonNetworkPower.com Firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, ASCO assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Information and specifications are subject to change without notice. Emerson, Consider It Solved., Emerson Network Power, the Emerson Network Power Logo, ASCO, Firetrol and the Firetrol Logo are trademarks or registered trademarks of Emerson Electric Co. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. ©2013 Emerson Electric Co. SD901-50 (A)