DC Power for Business-Critical Continuity™ Rectifier R48-3200 Key Features n3200 watt rectifier designed for -48V DC power applications nOptimized depth – reduced footprint allows installation in short-depth racks and cabinets nDSP (Digital Signaling Processor) means fewer components, optimized operation and active load sharing for increased reliability The reliable and efficient R48-3200 rectifier reduces power consumption, lowering operating cost. Description The 3200 watt rectifier (R48-3200) is designed to convert standard AC supply voltages into stable nominal -48V DC voltage that is adjustable to application needs. The R48-3200 is a constant power rectifier designed with the latest patented switch-mode technology using DSP (Digital Signaling Processor) functionality for efficient operation. For a higher load capacity, rectifiers can be connected in parallel, and intelligent control can be added with the help of a separate controller. nCompliant with global standards – delivers quality, performance and reliability no matter what the application or location demands nHigh efficiency, up to 92%, reduces power consumption for lower operating costs nHot pluggable – facilitates future extensions nWide input voltage range – operates in the most demanding environments where input voltage changes nWide temperature operating range (-40°C / -40°F to +75°C / 167°F) meets the harshest climatic environment requirements 2012.09 1 Rectifier R48-3200 Psophometric Noise (system) Temperature Derating Control and Monitoring Rectifier Alarm and Signaling Visual Indications Environmental Temperature Range, Operating Temperature Range, Storage Relative Humidity Altitude 45 50 55 120 70 80 60 40 20 0 -40 -20 0 20 40 60 80 100 Temperature (°C) Output Power vs. Input Voltage at Temp <45°C See diagram 67A 0 to 67A 92% <1 mV <32 dBrnc (See diagram) 65 100 -42 to -58 V DC 3200W@Vout >48VDC 85 120 176 290 100 80 60 40 20 0 0 50 100 150 200 250 300 350 Input Voltage (VAC) Alarm and status reported via CAN bus to system controller Green LED: Normal Operation Yellow LED: Alarm Red LED: Failure Flashing Red LED: Fan Failure Safety -40 to +75°C, -40 to +167°F -40 to +75°C, -40 to +167°F 0 to 95% 2000 m, 6560 ft at full power ETSI EN 300 386 class B, FCC CFR 47 Part 15 class B, Telcordia GR-1089-CORE class B IEC 60950, EN 60950, UL 60950 Mechanics Dimensions (H x W x D) Weight 132 x 85.3 x 287mm / 5.2 x 3.36 x 11.3 inches 3.5kg / 7.7Ibs Other Parts Controller Units See separate ACU/ACU+ and SCU/SCU+ datasheets EMC Output Power vs. Temperature 264V ≥ Vin ≥ 176VAC % of max output power DC Output Output Voltage, Adjustment Range Output Power Output Power, Derated for Input Voltage Output Current Output Current Limit Set Point Efficiency 200 to 250 V AC 85 to 290 V AC 45 to 55 Hz 20A 0.99 <5% from 50 to 100% of rated load Output voltage vs. Output current, max. output power 3200 W Output Voltage (V) AC Input Input Voltage, Nominal Input Voltage, Permitted Variation Line Frequency Max Input Current Power Factor THD (Total Harmonic Distortion) Diagrams % of max output power Technical Specifications 70 60 50 40 30 20 10 0 0 55A 10 15 20 25 30 35 40 45 50 55 67A 60 65 70 75 Output Current (A) Ordering Information Model Number 1R483200XXX Description Rectifier 48V, 3200W EmersonNetworkPower.com/EnergySystems (North America) EmersonNetworkPower.eu/EnergySystems (EMEA) © Emerson Network Power Energy Systems North America 2012. Business-Critical Continuity™, Emerson Network Power™, the Emerson Network Power logo, Emerson® and Consider it Solved are service marks and trademarks of Emerson Electric Co. EnergyMaster™, eSure™, NetPerform™, NetReach™, NetSpan™, NetSure® and NetXtend™ are trademarks of Emerson Network Power Energy Systems North America. 2 2012.09