400 Series 440 Surge Protective Device – Discrete 10-Mode Submittal Specification General Specifications Maximum Continuous Operating Voltage Short Circuit Current Rating (SCCR) Maximum Surge Current Rating 120VAC 150%, all others 115% 200kAIC 50kA Per Mode/150kA Per Phase 100kA Per Mode/300kA Per Phase 47-63Hz 40dB Max (Type 1), 60dB Max (Type 2) Type 1 / Type 2 20kA Green/Red LED, Audible Alarm, Alarm Test/Silence Feature, & Relay Alarm Contacts N-G Indication, Surge LED, Surge Counter, ATDS ANSI/UL 1449 Third Edition Type 1 or Type 2; cUL CE, IEC61643-11 Class I/II NEMA Type 4X Optional: NEMA 12, 4 (Steel) Standard Non-Metallic Enclosure- 3.8 lbs (1.8 kg); Optional NEMA 12 or 4 Enclosure- 12.7 lbs (7.8 kg) 10 Year Replacement Operating Frequency Range EMI/RFI Noise Rejection UL1449 Location Type UL1449 Nominal Discharge Current (In) Status Indication (Standard) Status Indication (Optional) Certifications IEC Class Standard Enclosure Discrete 10-Mode Option The 440 offers a Discrete “10-Mode” protection option, (up to 100kA/mode, 300kA/phase when adding L-N+L-G+L-L modes). This may be a requirement on some commercial projects based on performance advantage claims; including increased operational life, enhanced durability due to lower component stress, improved transient response and increased surge current sharing. We have a long history of achieving those same results with our standard mode/connection methods and configurations. However, for those projects that are specified with this requirement, the 440 is available in a Discrete 10-Mode construction format. Weights Warranty ANSI/UL 1449 Third Edition, Type 1 VPR’s Source Configuration SA, YA YC YD DB / DF / DG Model Number Configurator L-N 800V 1200V 1500V N/A L-G 800V 1200V 1500V 1200V / 1800V / 2000V _____________ 4 4 0 L N Configuration & Voltage SA Single Phase, 3W+G (L1, L2, N, G) YA Three Phase WYE, 4W+G (L1, L2, L3, N, G) Three Phase WYE, 4W+G (L1, L2, L3, N, G) Three Phase WYE, 4W+G (L1, L2, L3, N, G) YC YD DB DF DG Three Phase Delta, 3W+G (L1, L2, L3, G) Three Phase Delta, 3W+G (L1, L2, L3, G) Three Phase Delta, 3W+G (L1, L2, L3, G) 120/240 VAC 120/208 VAC, 127/220 VAC 05 10 277/480 VAC, 254/440 VAC 220 VAC, 230 VAC, 240 VAC 480 VAC 1 Replace the “J” in the standard model number (11th digit) with an “L” or “G” as shown below for an optional steel enclosure. S Standard X Consult Factory for additional source configurations, Surge Ratings, Monitoring Options, Enclosure Ratings, Etc. For a unit with the RJ-45 Ethernet port accessible on the front cover, change the enclosure rating from NEMA 4X (440xxxxxxxTJxx) to NEMA 1 (440xxxxxxxTCxx) 100 Emerson Parkway Binghamton, NY 13905 P (607) 721 8840 P (800) 288 6169 F (607) 722 8713 E contactsurge@emerson.com 4.9” [124] * Model Number 440xxxxxxALxx 440xxxxxxAGxx 10” x 8” x 4” [254] x [203] x [102] * Steel enclosure units require the “A” monitoring option. “A” option plus N-G LEDs & Surge LED “A” option plus N-G LEDs & Surge Counter CUL Approvals Advanced Transient Detection System See publication SL-70109, TS-70109 For all applications requiring CUL approvals, change the SPD model number from a UL Type 1 (440xxxxxxxx1x) to a UL Type 2 (440xxxxxxxx2x) Advanced Transient Detection System NEMA 4X (“J”) Dimensional Information 9.6” [244] Enclosure Type NEMA 12 Steel NEMA 4 Steel Monitoring Option Red & Green LEDs, Relay Alarm Contacts & Audible Alarm 600 VAC External Ethernet Port Option N-G 800V 1200V 1500V N/A Optional Steel Enclosures NEMA 4 or NEMA 12 S Additional Accessories Surge Rating 50kA Per Mode 150kA Per Phase 100kA Per Mode 300kA Per Phase A L C T 346/600 VAC J L-L 1200V 2000V 2500V 2000V / 2000V / 3000V A Web-Based Power Quality Monitor Integrated within a Surge Protection Device ½” NPT FLEXIBLE CONDUIT ½” NPT FLEXIBLE CONDUIT (24”) AND CONNECTOR ASSEMBLY 4.0” [102] Real-Time Measurements Event Logging with Time/Date Stamp Embedded Web Page Ethernet, MODBUS, RS-485 Communications SPD Health Status - % Protection remaining LCD Display 2.1” [53] 1.7” [44] SS-70112 Rev 2 1-15