Liebert Power Meters

advertisement

Liebert

®

Power Meters

Improve Thermal Unit Performance and Visibility with a Simple Factory Install, or a Hassle-free Upgrade

HVAC energy costs are a signifi cant expense in datacenter operations. Liebert Power Meters provide an easy-to-use solution to cut costs, through increased unit visibility, and fi ne tuning of the control to optimize unit performance.

Liebert Power Meters allow you to proactively monitor power quality issues.

These compact, intelligent power meters are available on new equipment at time of order and are retrofi table on existing Liebert equipment with AM/AG and

Liebert iCOM controls.

Factory programmed power meters are easily integrated into existing Liebert Thermal equipment with AM/AG or

Why do you need a Liebert Power Meter?

Hassle-free:

Easy integration to remote monitoring using the Liebert IntelliSlot Unity Communications Interface Card.

All meters are factory programmed, requiring no fi eld confi guration.

Application-specifi c design cuts down on site integration time.

Information is easy to read on the Liebert iCOM local display.

Easy to install plug-and-play retrofi t kits for existing Liebert iCOM and AM/AG controls.

The meter is DIN-rail mounted for fi eld retrofi ts. DIN-rail and other mounting hardware included with the meter.

Improves Visibility:

Line voltage and device current.

Accurately calculate data center cooling effi ciency.

Monitor power consumption before and after making changes to your control setup to pinpoint the highest payback strategy for your data center.

Provides a tool to identify issues with installed components such as motors and compressors.

Real Cost Savings Through

Optimized Performance:

You may qualify for energy rebates – check with your local electric company.

Minimize downtime by proactively monitoring power quality issues that could negatively impact unit performance, and taking corrective action.

Monitor real time power consumption to calculate ROI on energy saving upgrades such as EC or VFD upgrades, Liebert iCOM control enhancements and Optimized Aisle. Useful tool to improve facility power factor.

IT

IL

Y

V

EFFICIENCY

DEPLOYMENT

Device Name

Device Connection State

Phase Current

Y

AV

A

IL

Power Meter Options:

Analog Power Meter – Provides remote monitoring of kW. These devices can be connected to existing equipment with

AM/AG controls. One meter may be installed to monitor total kW or up to four meters may be installed to monitor individual component consumption.

Modbus Power Meter – Up to six meters may be installed on Liebert iCOM controlled equipment with 416761G3 control boards and later. These meters provide local and remote monitoring of:

Liebert iCOM to meter connectivity status.

Input under voltage event notifi cation.

Input RMS voltage leg to leg and leg to ground Input current for each phase.

Energy consumption in kilowatt hours (kWH).

Instantaneous power in watts (W).

Unit shutdown protection if a phase is lost.

The addition of a Liebert ® Power Meter to existing or new Liebert Thermal Management systems enhances the visibility of your data center thermal systems, and allows optimization of efficiency and availability.

Emerson Network Power

Global Headquarters

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

800 877 9222 Phone (U.S. & Canada Only)

614 888 0246 Phone (Outside U.S.)

Contact@EmersonNetworkPower.com

Voltage L1-L2, L2-L3 and L3-L1

Incoming Voltage Type

Total Watts

Power Consumed in kWh

Voltage L1-N, L2-N and L3-N

Total Watts Measured by

All Connected Devices

Total Power Used in kWh by

All Connected Devices

Liebert iCOM™

Current

Voltage

Time

Power factor is a way of measuring how effi ciently electrical power is being used within a facility’s electrical system. The Liebert power meter provides users an easy way to determine power factor when integrated to building management systems using the

IS-UNITY-DP.

Additional remote monitoring points are available with

Power Meter including:

System Input RMS A-B

System Input RMS A-N

System Input RMS

Current Phase A

System Input RMS B-C

System Input RMS B-N

System Input RMS

Current Phase B

System Input RMS C-A

System Input RMS C-N

System Input RMS

Current Phase C

Energy Consumption

Instantaneous Power

Input Under Voltage

Power Measurement

Description

Modbus Power Meter

Communication Lost

Emerson Network Power

Caribbean and Latin America

Office – United States of America

+1-954-984-3452 Phone

Ask.Cala@Emerson.com

Emerson Network Power Canada

3580 Laird Rd Unit 1

Mississauga

Ontario L5L 5Z7

+1 905 569 8282

Ask@EmersonNetworkPower.com

liebert.com

24 x 7 Tech Support

800 222 5877 Phone

614 841 6755 (outside U.S.)

EmersonNetworkPower.com

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. All rights reserved throughout the world. Specifications subject to change without notice.

All names and logos referred to herein are trade names, trademarks or registered trademarks of their respective owners. ® Liebert is a registered trademark of the

Liebert Corporation.

Emerson, Consider it Solved, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.

©2014 Emerson Electric Co.

AP-20041 (11/14) Printed in USA