An Application Guide From the Experts in Business-Critical Continuity™ Full Facility Surge Protection – Specialty Surge and Filter Application Application Guide Broadcast Transmitter Protection In a nanosecond, power surges, spikes and transients can compromise the quality of broadcasts, or worse, knock them off the air. Don’t allow ‘Dirty Power’ to put your transmitters and studio equipment at risk, safeguard broadcast operations from ‘Dead Air’ occurrences with Islatrol™ BC Series Active Tracking Filters™. Broadcast transmitter performance is enhanced with the installation of an upstream series filter. The Emerson Islatrol™ BC Series Active Tracking Filters™ are world class filters with a long history of providing the last line of defense ahead of the broadcast transmitter. These filters prevent the damage which can be caused by large surge events, but most importantly clean up the dirty power before it has a detrimental effect on the quality of the sound or picture quality resulting from high frequency noise. Type of Device 120/240V Single Phase 15 Amp 120/240V Single Phase 50 Amp 120/240V Single Phase 100 Amp 208Y/120V 100 Amp 208Y/120V 200 Amp 480Y/277V 100 Amp 480Y/277V 200 Amp 480Y/277V 400 Amp Part Number BC-2-215 BC-2-250 BC-2-2100 BC-3-2100WYE BC-3-2200WYE BC-3-4100WYE BC-3-4200WYE BC-3-4400WYE Low voltage noise from everyday events, such as turning on appliances or motors, causes long-term degradation of equipment Islatrol BC Series Telecommunications Shelters (Motorola R-56 Compliant) – 500 Series Telephone shelters, including 911 Shelters, require a higher level of surge protection. Motorola has a standard (R56) which has rigorous testing requirements designed to test for this type of installation. Emerson Network Power 570/560 Surge Protective Device offers a true, coordinated multi-stage system of suppression. It utilizes advanced SAD/MOV array technology, along with an active switch to share the surge and retain protective characteristics for industry leading transient suppression voltages up to 160kA surge current capacity, all for increased reliability. The 570/560 Surge Protective Device is Motorola compliant with the Motorola R56 standard and backed by a worry-free 10-year parts and 5 year labor warranty. Voltage 120/240V 208Y/120 V 480Y/277V Type 1 (SAD & MOV) Part Number 570SA16FNRJ1S 570YA16FNRJ1S 570YC16FNRJ1S Type 2 (MOV Only) Part Number 560SA16FNRJ1S 560YA16FNRJ1S 560YC16FNRJ1S Typical Applications Include: •Cell sites •Communication shelters •AC main and distribution panels •Load centers •Transmitters •Base Stations IEEE Standard IEEE Standard 1100 - 4.4.5 Potential impact of EMI: “Depending on the severity of the surge and the susceptibility of the equipment, three types of occurrences are possible… : data disruption, hardware stress, and hardware destruction.” IEEE Standard 1100 - 9L.1.6.3 “if surge protection is required for a building or factory, parallel-connected devices may be sufficient to proactively stop high-energy transients from mitigating downstream. On the contrary, if a susceptible or critical piece of equipment needs to be protected from transients or isolated from induced high frequency, than a series connected filter may be the better choice.” 100 Emerson Parkway Binghamton, NY 13905 P (607) 721 8840 P (800) 288 6169 F (607) 722 8713 E contactsurge@emerson.com AG-22019 Rev. 1 1/13 EMERSON NETWORK POWER SURGE PROTECTION INC MAY UPDATE OR REVISE PRICING AND PRODUCT INFORMATION AT ANY TIME PRIOR TO RECEIPT AND ACCEPTANCE OF A CUSTOMER ORDER. SUCH UPDATES OR REVISIONS SHALL BE COMMUNICATED ELECTRONICALLY TO CURRENT REPRESENTATIVES. DAYS TO SHIP MAY VARY DUE TO SIZE OF ORDER. ADDITIONAL PRODUCT DESIGNS ARE AVAILABLE, PLEASE CONTACT THE FACTORY FOR ASSISTANCE.