SECTION ____________ WET WELL PART 1 GENERAL 1.01 SUMMARY A. This Section includes all Wet Well required for the complete installation of the work. 1.02 REFERENCES A. Design, fabricate Wet Well and materials in accordance with manufacturer’s recommended procedures and the following codes and standards: 1. ASTM A193 - Stainless Steel Anchor Bolts 2. ASTM D 256 - Izod Impact Strength 3. ASTM D 570 - Water Absorption Rate 4. ASTM D 638 - Tensile Strength 5. ASTM D695 - Compressive Properties of Rigid Plastic 6. ASTM D 696 - Coefficient of Linear Expansion 7. ASTM D 790 - Flexural Properties 8. ASTM D792 - Density and Specific Gravity at 230 C 9. ASTM D2563-0 - Visual Defects 10. ASTM D 2583 - Indentation Hardness 11. ASTM D2584 - Resin, Glass & Filler Content 12. ASTM D3753-12 - Polyester Manholes 13. ISO1438/1-1980 - Open Channel Flow Measurement 15. OSHA 1910.27 - Fixed Ladders B. Composition of the Wet Well laminate shall be in accordance with the recommendations shown in the Quality Assurance Report for Reinforced Thermoset Plastic (RTP) Corrosion Resistant Equipment prepared under the sponsorship of the Society of the Plastics Industry, Inc. (SPI), and the Material Technology Institute (MTI) of the Chemical Process Industry for “Hand Lay-Up Laminates,” and shall meet the specifications for Type I, Grade 10 laminates shown in Appendix M-1 of said report. C. Manufacturer shall be experienced in the design and manufacture of specific Wet Well and accessories for a minimum period of 20 years. D. Manufacturer must provide warranty for 25 years against failure due to corrosion. 1.03 SUBMITTALS A. Submit the following for acceptance: 1. Approval Drawings PHONE - 503.692.5460 | FAX - 503.210.0602 | E-MAIL - sales@plasti-fab.com | WEB - www.plasti-fab.com ADDRESS - P.O. Box 100 9665 SW Tualatin-Sherwood Rd. Tualatin, Oregon 97062 1 a. Showing all critical dimensions. b. Showing principal parts and materials. 2. Spare parts list (when applicable). 1.04 DELIVERY, STORAGE AND HANDLING A. Ship all Wet Well with suitable packaging to protect products from damage. B. Protect Wet Well flanges, tabs and accessories from damage. C. The Wet Well shall be stored on a smooth flat surface, free of sharp objects, and if laid horizontally, shall be placed in such a way as to avoid structural damage. PART 2 PRODUCTS 2.01 MATERIALS A. Wet Well body shall be: 1. Engineered composite fiberglass reinforced plastic (FRP). a. Molded in one piece to create a seamless corrosion barrier impervious to moisture. b. FRP resin shall be Choose a material Wet Well Hardware (when applicable): Choose a material 2.02 WET WELL A. Acceptable Manufacturers: 1. Plasti-Fab Inc. a. Shall be Model Wet Well as shown on the contract drawings. 2. The Wet Well fabrication, engineering and customer support shall all be provided by the same company. Outsourcing any of these components is not acceptable. 3. To assure quality control and single source accountability the same manufacturer shall fabricate and fully assemble the Wet Well and all components. 4. Or approved equal. Pre-approved by Engineer at least 10 business days prior to bid date. a. Manufacturer must have a qualified Engineer on staff with at least 5 years experience with FRP 2.03 DESIGN CRITERIA A. Wet Well shall conform to ASTM D3753-12. B. Composition of the Wet Well laminate shall be in accordance with the recommendations shown in the Quality Assurance Report for Reinforced Thermostat Plastic (RTP) Corrosion Resistant Equipment prepared under the sponsorship the Society of the Plastics Industry, Inc. (SPI) and the Material Technology Institute of the Chemical Process Industries, Inc. (MTI) for “Hand Lay-up Laminates” and shall meet the specifications for Type 1, Grade 10 laminates shown in Appendix M-1 of said report. 1. Visual inspection for defects shall be made without the aid of magnification and defects shall be classified as to type and level as shown in Table 1 of ANSI/ASTM D2563-0, approved 1977, (or any subsequent revision). Allowable surface tolerances are as follows DEFECTS ALLOWABLE TOLERANCE Cracks Crazing Blisters None PHONE - 503.692.5460 | FAX - 503.210.0602 | E-MAIL - sales@plasti-fab.com | WEB - www.plasti-fab.com ADDRESS - P.O. Box 100 9665 SW Tualatin-Sherwood Rd. Tualatin, Oregon 97062 2 Chips Pits Dry Spots Fish Eyes Burned Areas Entrapped Air Wrinkles and solid blisters, not to exceed 1/8” Surface porosity (pinholes or pores in the laminate surface) Exposed Glass Exposure of cut edges Scratches Foreign Matter Maximum Deviation: 10% of thickness None None None more than .002” deep (.05mm) None 2.04 CONSTRUCTION 2. Wet Well Each Wet Well shall be a complete integral unit consisting of: a corrosion resistant fiberglass reinforced plastic (FRP) manhole with sealed fiberglass bottom, fiberglass access ladder, sump and accessories as required. 3. Wet Well body shall be totally manufactured of fiberglass reinforced polyester. 4. Each Wet Well shall be molded individually to the exact dimensions specified. 5. The thickness of the walls and floor of the Wet Well shall be not less than 1/2" (12mm) thick. 6. Wet Well shall be manufactured of reinforced thermoset plastic in one integral piece that is structurally strong, lightweight, watertight and corrosion resistant to salt water, ground water, corrosive soil conditions and many commonly encountered industrial chemicals. 7. Wet Well shall have UV Stabilizing pigment in the Resin to provide longterm protection from UV. 8. Wet Well inside surface shall be smooth, isophthalic gelcoat of 10 - 20 mil (0.25 - 0.51mm) thickness. Exterior Surface shall be grey gel coat 15-20 mil (0.25 – 0.51mm) thickness. 9. The surface shall be free of exposed reinforcing fibers. 10. The minimum glass content shall be 30% exclusive of gelcoat surfaces. 11. The manhole sides, bottom and external pipe stubs shall be designed to withstand a static load of 150 lb/ft per foot (68 kg/305mm) of depth with less than l/4" (6mm) deflection. 12. There shall be no light duty angles of flanges protruding beyond the manhole that can be damaged by shear or load forces. 13. Inlet and Outlet Pipes: The FRP manhole shall be provided with pipe stubs to match connection to I.D. and O.D. of incoming and outgoing pipe. a. Two neoprene boots with stainless steel clamping bands shall be supplied and sized to connect inlet and outlet pipe stubs to the pipeline. b. Pipe stubs shall have slip flanges for connection to existing line. PHONE - 503.692.5460 | FAX - 503.210.0602 | E-MAIL - sales@plasti-fab.com | WEB - www.plasti-fab.com ADDRESS - P.O. Box 100 9665 SW Tualatin-Sherwood Rd. Tualatin, Oregon 97062 3 14. Cover a. The Wet Well will be furnished with a fiberglass cover equipped with heavy duty stainless steel hinges having l/2" (12mm) diameter hinge pins and stainless steel hasp for locking. The cover shall be sufficient strength to withstand 1000 lbs. (454kg) top load. The cover shall overlap the manhole and seat on a neoprene seal to prevent dirt, rain and debris from getting into the manhole. b. The Wet Well shall have a gastight aluminum lid for non-traffic loads mounted with a 20" / 24" (508mm / 610mm) concentric manway. c. The Wet Well shall have a concentric manway designed to withstand a 16,000 lb. (7257kg) vertical dynamic wheel load (H-20), plus lateral forces from earth loading, ground water and frozen soil. The manhole opening shall be a (4' (1219mm) diameter barrel use: 221/2" (572mm) I.D or 28" (711mm) I.D. - 5' (1524mm) diameter barrel use 22-1/2" (572mm) I.D., 28" (711mm) I.D. or 36" (914mm) I.D.) manway for use with a cast iron cover, suitable for H-20 highway loading. d. The Wet Well shall have aluminum hatch access as shown on the contract drawings 15. Internal Ladder: The ladder rungs shall have a non-slip traction surface and internal stainless steel safety bar. The ladder shall meet or exceed OSHA General Industry Standards, Part 1910.27 for "Fixed Ladders". 16. A l/2” (12mm) thick expanded polystyrene bead board will be supplied for placement on the concrete slab under the manhole. 17. Options a. Utility Tap: The manhole barrel shall be fitted with a 2" (51mm) FRP through-wall utility tap(s) having threaded connections to permit sub-grade entrance for power, sample or recording lines without damaging the watertight integrity of the manhole. b. Head deflector / lid warning sign / ladder up with safety track. 2.03 PHYSICAL PROPERTIES A. Structural characteristics for a 1/8” (3mm) glass mat laminate shall meet the following minimum physical properties: Tensile strength Flexural Modulus Flexural Strength Compressive Strength Impact Strength Water absorption 15,000 psi (1034 ksc) 1,000,000 psi (70307 ksc) 20,000 psi (1406 ksc) 22,000 psi (1547 ksc) 9.0 ft-lbs/in. (1.24 kgf.m/25mm) 0.13% (in 24 hours) PHONE - 503.692.5460 | FAX - 503.210.0602 | E-MAIL - sales@plasti-fab.com | WEB - www.plasti-fab.com ADDRESS - P.O. Box 100 9665 SW Tualatin-Sherwood Rd. Tualatin, Oregon 97062 4 2.04 DIMENSIONS A. Fiberglass barrel shall be Choose Size diameter. B. Manhole invert to grade as shown on the contract drawings. The fiberglass Wet Well height from the outlet pipe invert to the top cover (shoulder of the concentric reducer) as shown on the contract drawings. PART 3 EXECUTION 3.01 INSTALLATION A. Verify that dimensions are correct and project conditions are suitable for installation. Do not proceed with installation until unsatisfactory conditions have been corrected. B. Thoroughly clean and remove all shipping materials prior to setting. C. Install products in accordance with engineer’s specifications, local codes, general comments below and the Manufacturer’s recommendations. D. Care shall be taken in the handling, storage and placement of the Wet Well in preparation for installation. The contractor shall become familiar with the recommended handling and installation procedures used with fiberglass Wet Well to insure that the manhole is not damaged, and is installed in a manner that is consistent with obtaining good sediment, trash and oil retention results. E. Slinging will be accomplished using nylon or other fabric material. Under no circumstances shall cable or chain slings be used in direct contact with fiberglass surfaces F. The Wet Well shall be installed level end-to-end and side-to-side, and must remain level throughout installation. G. The site shall be excavated wide enough to accommodate the manhole and to provide a safe working environment for workers. H. The contractor shall provide a level concrete slab with a smooth troweled surface. Pad elevation shall be as shown on the drawings, and positioned so that the invert of manhole piping matches that of the pipeline. Prior to manhole placement the slab shall be cleaned of all sharp objects and debris. I. The foam pad supplied with the manhole shall be placed in the proper position. J. If the pipe is already in place the neoprene boots and s/s bands shall be slipped onto the pipe ends before lowering manhole onto concrete slab. The neoprene boots can be slipped over pipe ends and the stainless steel clamps tightened securely. Under no circumstances shall petroleum lubricants of any type be used to install neoprene boots. K. Wet Well shall be lowered onto pad in accordance with the manufacturer's written recommendations. L. After the level is confirmed all anchor bolts shall be securely tightened. M. Backfill 1. Care shall be taken to avoid uneven backfill loads on the FRP manhole. 2. Groundwater or surface water runoff shall not be allowed to accumulate in the open excavation around a manhole that has not been completely backfilled. 3. Backfill materials shall be placed evenly around the packaged manhole in approximately 12” (305mm) lifts. PHONE - 503.692.5460 | FAX - 503.210.0602 | E-MAIL - sales@plasti-fab.com | WEB - www.plasti-fab.com ADDRESS - P.O. Box 100 9665 SW Tualatin-Sherwood Rd. Tualatin, Oregon 97062 5 4. If materials other than pea gravel or sand are to be used as fill there shall be no soil lumps or sharp objects such as rocks or concrete, or other debris larger than 1” (25mm) in size. 5. All fill work will be in compliance with local codes, and shall meet the inspection standards established by the engineer. 6. Stable Soils: Bearing capacity greater than 2000 lbs/ft 2 (186 kg/m2). Native soil, 1/4" x 3/8" (6mm x 9.5mm) round aggregate gravel or sand shall be used as backfill material, and placed in accordance with the above specifications. 7. Unstable Soils and High Water Tables: Bearing capacity less than 2000/lbs/ft2 (186 kg/m2). Sand or 1/4" x 3/8" (6mm x 9.5mm) rounded aggregate, compacted, shall be used in unstable soils such as expansive clays, marsh and/or where the water table may be less than 5’ (1524mm). from finished grade. Selected backfill shall be placed in maximum 12” (305mm) lifts, a minimum of 24” (610mm) surrounding the manhole, and compacted to 85% Standard Proctor Density. 8. Finish to Grade: For concentric top, contractor shall finish to grade using brick and mortar or precast concrete rings to construct chimney of required height. Mortar bed and first grade ring shall be firmly supported on flat, bearing shoulder of the packaged manhole. 3.02 ADJUSTMENT AND START UP A. Check Wet Well for being level both directons and for meeting dimensional requirements and cleaned per manufacture’s instructions. B. Site to be left clean and free of any debris. C. Representative shall complete a Certification of Proper Installation and provide copies to the Owner, Engineer, Contractor and Manufacturing Facility. (When applicable) 3.02 FIELD TESTING (OPTIONAL) A. Qualified Factory representative shall provide (8) hours of training for facility employees. (Optional) B. Representative shall complete a Certification of Proper Installation and provide copies to the Owner, Engineer, Contractor and Manufacturing Facility. (When applicable) END OF SECTION PHONE - 503.692.5460 | FAX - 503.210.0602 | E-MAIL - sales@plasti-fab.com | WEB - www.plasti-fab.com ADDRESS - P.O. Box 100 9665 SW Tualatin-Sherwood Rd. Tualatin, Oregon 97062 6