Dear prospective customer
This prestentation is a showcase for batch operation with LabVision
the leading process control management system. LabVision is known
for its visualization and automation capabilites in laboratories, pilot
and mini plant around the world.
To gain a quick overview please click on "short version". For further
reaching information please click on "full version".
We will be glad to present our products to you during a personal
conversation or in a live-internet-presentation.
Recipe Control with HiBatch
Dialogue and display boxes
may be changed to your
purposes.
A recipe parameter set may
be saved and loaded
anytime.
Press  to continue
Press  to go back
The recipe control system HiBatch is designed
according to NAMUR specifications and will reduce
costs, improve quality and helps to meet GLPstandards in your laboratory.
Automated process execution guarantees optimal
reproducibility and documentation.
The recipe module HiBatch allows the creation of
recipe flow diagrams in minutes without programming
knowledge.
Unit Operations Library
Press  to continue
Press  to go back
In the unit operations library you find pre-programmed
operations for dosing, tempering, pH - control, distillation
etc.
All these To
functions
been
programmed
create have
a recipe
program,
simplywith
dragHiText.
the
You mayneeded
modify these
functions
to your
and
function
blocks from
thepurposes
unit
expand the
library to your
requirements.
operations
library
to the recipe flow chart.
Intuitive Operability
0,00
Press  to continue
Press  to go back
To parameterise a function block you just need to
By
clicking
oropen
“OK” the
a routine
will verify
click
on it in“apply”
order to
initialisation
form.
your
input
on plausibility.
This is
where
you may enter e.g. a new quantity.
Flexibility and Ease of Use
Press  to continue
Press  to go back
During the recipe’s execution the active function block is
A
special
control
may be
to each
unitisto
dyed
yellow
and ainstance
control form
withadded
relevant
values
You
may
change
parameters
during
runtime
by
using
stop
and
continue
its
operation
at
definable
conditions.
shown.
the
Online
form.
In
this
example,
if the
inside
The
execution
ofDosing1
the stepwill
andbe
itsinterrupted
result will be
saved
in
At
the
Online
form
all
parameters
for
which
changes
temperature
exceeds
90
degrees
and
will
be
continued
the monitoring report and optionally documented in aare
impossible
or85unsuitable
areform.
blocked.
iffree
it declines
degrees.
composeable
protocol
Automatic Creating of Documentations
Press  to continue
Press  to go back
With the (WYSIWYG) form editor you may create
sheets with user-defined combinations of indicating
and input fields, diagrams, designs and pictures in
minutes.
Accumulated and computed data will be inserted
into the sheet at run-time. All sheets may be printed
and saved.
Thereby you receive a clear and significant
documentation with little effort.
Production of Self-Describing Programs with HiText
With HiText you may drag instructions
simply from a library on the working sheet.
The syntax is examined during the input.
Errors are underlined in red and announced
in the status bar.
Press  to continue
Press  to go back
HiText is a language for multitasking control, online evaluation and
communication.
HiText was developed in co-operation with users from the chemical
industry. The ambition was to create a self-describing and
documenting language for non experts. The module contains a
comfortable editor with a set of auxiliary functions and error search
assistance.
Automatic production of laboratory journals
Press  to continue
Press  to go back
Theyour
All
Your
With
laboratory
the
selection
worksheets
Labvision
of
journal
values
modul
will
can
will
be
Laborjournal
be
presented
beprinted
storedand
periodically
in
you
aexported
clearly
may adjust
and
and
as freely
pdf
eventthator
configurable
controlled
laboratory
editable
rtfand
journal
file.
tables
cantobe
and
ones
supplemented
xy/xt
you–might
diagrams.
already
with comments.
use.
Recipe control with EasyBatchTM
Beside the commands Set, Wait till, If etc.
EasyBatch can call HiText programs.
Thereby the possibilites are almost
unlimited.
EasyBatch provides a new way of recipe creation for
small to medium complex processes. EasyBatch enables
the user to create a table based, self documenting recipe.
It distinguished it self due to easy and intuitive usage.
EasyBatch can be used in combination with manual
operation.
Press  to continue
Press  to go back
Consistent Representation of Values, Events and Phases
The event plotter for visualisation of events
(e.g. alarm messages, user comments).
The analog plotter shows the curves’
shape.
The phase plotter for visualisation of
operational sequences as a bar chart,
here the procedure of the recipe
control.
Press  to continue
Press  to go back
LabVision ensures gapless (compressed!) recording of
all data in a database.
In the Multiplotter you may view current and historical
data.
In addition to the measured and computed values,
events and phases will be visualised by symbols and
bars. Thus the values, events and phases are shown
in their most consistent and clear form.
Multiple Reading Utilities
Various measurement functions will assist you
for reading and analysing purposes. Trend,
gradient, integral and statistical values may also
be read directly. All values may be exported to
different file formats.
You may select directly a representation time
period, zoom in time intervals or choose a
historical batch process from a list.
Press  to continue
Press  to go back
The symbols shown by the event plotter will explain
their cause when hovering your mouse above them.
By clicking at a symbol the monitoring report will be
opened.
Online Measured-Value-Analysis
Press  to continue
Press  to go back
The time axis of the online diagram shows either
batch or the general time.
You may fade in historical values for comparison.
The diagram may be parameterised by menu or
HiText - programs.
Thereby the online diagram is especially suitable
for batch work.
Process Report
Press  to continue
Press  to go back
You may also
Selection
filtersselect
will help
a filter
youfor
to batch
retainoperation
the overview
to
even withallmany
highlight
appropriate
entries. messages.
Monitoring and Messaging
In the message report all warning and alert messages as well as
acknowledgement-requiring conditions are listed. Each data point may be
provided with several monitoring conditions.
For the treatment of the monitoring events you may plan various reactions:
text messages, starting a control program, alarm calls by E-Mail, SMS or
by telephone announcement.
Press  to continue
Press  to go back
Connecting Sensors, Actuators and Devices
T_RI_X
Connecting sensors, actuators and devices is of
great ease:
• choose a desired name,
• choose an automation unit and the data point type,
Press  to continue
Press  to go back
• select a projected connector by clicking or
choose the blinking one by clicking OK.
Creation of Flow Charts
This library includes all elements of the DIN/EN 28004
catalogue.
A special library with glass apparatus and laboratory
devices is available optionally.
Press  to continue
Press  to go back
You may already use the integrated RI flow sheet editor at your
prearrangements.
Standard drawings based on DIN/EN 28004 and administration
of additional technical apparatus are only a few of his strengths.
Process Pictures for Visualising and Manual Intervention.
Press  to continue
Press  to go back
The worksheets may be dynamized by indicating and controlling elements,
process dependent texts and pictures up to online rendered digital photos.
Here you may observe the current plant condition and make control
interferences.
No programming knowledge is needed to create a worksheet. The user
administration and access monitoring protect against unauthorised control
changes.
Micro Reactions Technology
Press  to continue
Press  to go back
LabVision is also suitable for micro reaction systems and
parallel reactor systems. To design your plant’s worksheet
drag the needed components from the library onto the
worksheet.
Device Components
Press  to continue
Press  to go back
Realisation
of these functionalities
with
conventional
Device components
with application
oriented,
controlling
systems
requires
extensive
controlling
knowledge
and
and communication functions are available. Thereby
an
much
time
to
establish
the
controller
parameters.
With
easy
realisation
of
automation
and
central
engineering
Attaching
balances,
thermostats
or agitators
to a
the
LabManager
it is simple,
the
application
asserial
dosing-,
temperature
-, with
pHsince
or
vacuum
control
is
interface,
is
easy
the
help
of
the
orientated
device components parameterise themselves.
possible.
communication components.
Serial Port Devices
Press  to continue
Press  to go back
Devices with serial interface, whose parameters aren’t
preset in LabVision, are easily integrated by means of the
NAMUR interface device. Different values and parameters
may be sent and received over one interface.
HiSim - Simulation
HiSim allows you to reproduce the
process itself. This may be done by
assigning the process values to the
data points of the inputs, e.g. 99 degr.
to a temperature sensor input. Those
values may be calculated from the
data point values of the outputs.
Press  to continue
Press  to go back
A newThe
project
integrated
may be
PNK
developed
simulator
and
simulates
tested without
functionalities
a PNK connected
of the PNKto
the computer
includingthereby
the measured
makingvalues,
it possible
controllers,
to simulate
monitoring
the LabManager
conditionsas
well as
etc..
theAwhole
project
process
createdorwith
plant.
theThe
helpneeded
of HiSim
programming
may be transferred
language
to
HiSimthe
is LabManager
in major partswithout
similar changes.
to HiText.
HiTune
Press  to continue
Press  to go back
HiTune
After successful
calculates the
determination
controller parameters
of the parameters
from the
controlled
HiTune system.
adjusts the
So controller
this time consuming
with the determined
step-by-step
P, I
task
and
is D
just
parameters,
a matter oftype
minutes.
and sample rate.
A complete Project Documentation in a Hand‘s Turn
Press  to continue
Press  to go back
With LabVision you enjoy the comfort of creating a
documentation in seconds. Instead of working on details
project
documentations
be
for days you The
just need
a mouse-click
now.may
Unnecessary
exported
to
Excel
for
further
processing
or
documentation parts may be deselected with a mouse
to
HTML,
e.g.
for
a
company‘s
intranet.
click.
The Maximum Automation,
with the Minimum Engineering
Thank you for your interest!
We would be pleased, if this presentation could
convince you. This presentation showed batch
operating. LabVision is evenly qualified for continuous
processes!
With the LabVision Demo version on this CD, you may
explore the program on your own. We would be glad to
demonstrate LabVision to you in person.
You may have special questions afterwards. For
further information on this as to any other of our
products we will be at your service under
+49 (0) 2407 91010-10 or
info@hitec-zang.de.
Best regards,
HiTec Zang GmbH
www.hitec-zang.com
Download