geniovent.uno

advertisement
ENERGENIO
®
geniovent.uno
technical data & information
plus
ENERGENIO
®
geniovent.unoplus
Die Marke für Lüftung
Decentralized ventilation system
The geniovent.unoplus is an innovative decentralized ventilation unit with heat
recovery and sound insulation. The installation requires only one hour and does
not cause dust or dirt. The ventilation unit is designed for the needs of property
developers and the housing industry for both new construction and in the case of
renovation.
Controlled ventilation is effective against building physical problems, such as mold.
The unit acts as a problem solver with comfort features.
Due to its air-flow rate of up to 60m ³/h the ventilation system can also be used in
larger rooms.
efficiency
The innovative porcelain heat storage provides up to 90% heat recovery. In
addition to efficient energy saving, the device offers best room hygiene by mold
prevention, reduction of indoor air pollutants, pollen, dust, insects and noise
pollution.
airflow
up to 60 m³/h
fan
The built-in fan with the latest EC technology operates nearly silent with very low
energy consumption. For this reason, the geniovent.unoplus is a super quiet
energy saving ventilation.
air exchange
a device max. 30 m³/h
kitchen & bath
possible with passive element or
Maico ECA ipro, ECA piano
heat exchanger
porcelain heat storage to 90% heat recovery
fan
energy saving and noiseless
DC motor
filter
2 filter G3, each inside and outside
antifreeze
unnecessary
maintenance
easy filter replacement without tools
filter
The geniovent.unoplus has two coarse dust filter (G3). The use of fine dust filter
(M6) on the inside is optional.
The pollen and coarse dust filters usually have to be changed once a year. The
control panel displays the need for a filter change. Changing the filter requires the
opening of the front cover so that the device can be extracted. The filters can be
easily removed.
antifreeze
Because of its special porcelain heat storage the geniovent.unoplus does not need
a frost protection, so that it can be used all year round. The low water absorption of
the memory makes this possible.
operation
The geniovent.unoplus can be set via the external controller. Three modes and five
ventilation levels are preinstalled. The modes in detail:
D:
. manual setting of fan speeds. The units are in heat recovery mode.
Q: cross ventilation with preset ventilation levels. Devices, which are mutually
directed (always two) move in one direction only, there is no heat recovery.
E: dehumidification program: the space is dehumidified as efficiently as possible.
2
www.energenio.de
ENERGENIO
®
geniovent.unoplus
Die Marke für Lüftung
Installation
Wartung
The geniovent.unoplus can be easily integrated into the wall. The inconspicuous inner element fits almost
invisible to the wall. The drilling template specifies the drilling and connection dimensions.
assembly:
Attaching the template
Mark the hole and cable entry
Drill or lift hole
Sliding the mounting sleeve and secure it with not oppressive construction foam
Placing the inner panel cover and connecting the cables
Insert and connect the ventilation unit
Wartung
For maintenance of the geniovent.unoplus only a regular filter change is required. The filter
should be replaced at least once a year. The heat accumulator is set between the filters, so its
maintenance-free.
technical data
device type
units
geniovent.uno W
geniovent.uno L
airflow
[m³/h]
17,5 - 55
17,5 - 55
amount of air
[m³/h]
9 - 27,5
9 - 27,5
efficiency
[%]
80 - 90
wall thickness min.
[mm]
265
diameter of device
[mm]
200
diameter borehole min.
[mm]
210
[kg]
8
Merkmale
weight
shell-set (hood or soffit channel with wall spacer)
Wartung
installation-set
www.energenio.de
3
ENERGENIO
®
geniovent.unoplus
Die Marke für Lüftung
benefits
Easy to install
High efficiency up to 90%
geniovent.unoplus capacity up to 55 m³ / h for living rooms
EC motor technology with low power consumption
Easy and space-saving installation in the wall
Elegant, stylish and simple design
Humidity control in the room due to ceramic heat exchanger
100% on-demand control - 5-stage integrated controlt
secifications
Wartung
geniovent.duo
level 1 (min.)
amount of air
power
[m³/h]
[W]
sound power level
LwA 7
exhaust air
[dB(A)]
LwA 8 supply
air
[dB(A)]
17,5
2
31
29
level 2
20
2,3
35
32
level 3
30
2,9
41
38
level 4
45
3,7
49
46
level 5 (max.)
55
4,8
52
51
Presure dPst [Pa]
Pressure-flow rate characteristic curve
exsample:
Calculation of the sound pressure level at a supply air
volume of 30 m³/h
LpA7, 30 = LwA7, 30 - 11 dB = 27 dB(A)
Information
The dimensioned drawing contains the information
about the positioning of the connections.
40
For specifications, please visit our Homepage www.energenio.de - in the download section for
planner.
35
30
25
20
15
10
5
5
10 15 20 25 30 35 40 45 50 55 60
flow rate [m3/h]
Wg
4
the sound power level is directly measured on the
device in the openings of air connections
For the calculation of the sound pressure level can be
accepted a value of 11 dB for a normal living room:
www.energenio.de
ENERGENIO
®
geniovent.unoplus
Die Marke für Lüftung
insideview device
operator panel control
porcelain heat storage
shutter motor
EC-fan
cover (Berker S1 | standard)
display ventilation level
selector button ventilation level
selector button ventilation program
internal filter G3 (M6 optional)
fan connector board
Version W (wall) - Installation in the outer wall
plastic cover | white (inside)
insertion ventilation unit (wall)
exterior hood | polished stainless steel or white RAL 9010
(on the outer wall)
display ventilation program
Version L (soffit; germ. Laibung) - Installation in the outer wall
Kunststoffabdeckung | weiß (Innen)
insertion ventilation unit (wall)
soffit channel | aluminium sheet with mounting tabs |
grid outside in polished stainless steel (on and in outer wall)
www.energenio.de
5
EG.GVU+ | w-1.8 | 201312
ENERGENIO
®
Industriestraße 10
D- 35232 Dautphetal
Deutschland
T: +49-6466-89797-0
F: +49-6466-89797-15
info@energenio.de
www.energenio.de
Download