APPENDIX 3. Lead Acid battery testing, charging and maintenance equipment and corresponding NSNs.
Pallet Charger
NSN: 6130-01-532-7711
The Pallet Charger is a 12V, 6.5 amp per channel, 12station charging unit. It uses universal electrical
input (110Vac – 250Vac). The charger can be
connected to any type or size of 12V lead acid
battery (AGM, GEL or flooded cell). Charge stations
1-12 each operate in isolation from one another,
allowing any combination of batteries to be
recharged at the same time.
Example: Pallet Charger in use.
Pro HD
NSN: 6130-01-500-3401
The Pro HD is an auto sensing 12/24V, 50 Amp
charger designed to charge any type of lead acid
battery (AGM, GEL, or flooded cell) using the
supplied clamps or NATO connector. It uses
universal electrical input (110Vac – 250Vac).
Smart charging with one-switch operation
minimizes operator training requirements.
Example: ProHD Charger servicing all
batteries (24V mode) on an FMTV.
Battery Service and Maintenance System (BSES)
NSN: 6130 01 541 9731
•
•
•
•
•
Kit Includes:
1 – HD Pallet Charger
1 – Redi-Pulse Pro-HD 12/24V Charger
1– Redi-Pulse Pro-12 Maintainer
10 – MBT-1 Battery Testers
1 – 490PT Battery Analyzer
Example: ProHD Charger recovering back
2 batteries (12V mode) on an FMTV.
APPENDIX 3. Lead Acid battery testing, charging and maintenance equipment and corresponding NSNs.
12 Station Bench Top Charger
Part No: 746-850
NSN: Pending; Can be ordered
via part# and cage code, or credit card
The 12 station Bench Top Charger is a 12V, 6.5 amp
per channel, 12-station charging unit. It uses
universal electrical input (110Vac – 250Vac). The
charger can be connected to any type or size of 12V
lead acid battery (AGM, GEL or flooded cell). Charge
stations 1-12 each operate in isolation from one
another, allowing any combination of batteries to be
recharged at the same time.
Example: 12 Station Bench Top Charger in use.
Dual 24V Charger
NSN: 6130-01-609-9818
The Dual 24V Charger is a 24V, 3.5 amp per
channel, 2-station charging unit. It uses
universal electrical input (110Vac – 250Vac) .
The charger can be connected to any type or
size of 24V lead acid battery (AGM, GEL or
flooded cell). The 2 charge channels operate in
isolation from one another, allowing any
combination of batteries to be recharged at the
same time.
Example: Dual 24V Charger in use.
12V World Charger
NSN: 6130-01-477-4703
The 12V World Charger is a 12V, 20 amp per
channel. It uses universal electrical input
(110Vac – 250Vac) . The charger can be
connected to any type or size of 12V lead acid
battery (AGM, GEL or flooded cell).
Example: 12V World Charger in use.
APPENDIX 3. Lead Acid battery testing, charging and maintenance equipment and corresponding NSNs.
Dual Extreme 12V Charger
NSN: 6130-01-458-0984
The Dual 12V Charger is a 12V, 2.5 amp per channel, 2station charging unit. It uses universal electrical input
(110Vac – 250Vac) . The charger can be connected to any
type or size of 12V lead acid battery (AGM, GEL or
flooded cell). The 2 charge channels operate in isolation
from one another, allowing any combination of batteries
to be recharged at the same time.
Example: Extreme Dual 12V Charger in use.
Pro-12 Battery Maintainer
NSN: 6130-01-535-2718
The RediPulse Pro-12® keeps new or recovered
batteries from discharging while they are waiting to
be used. 12 separate channels each capable of
maintaining any type 12V lead acid battery (AGM, GEL
and flooded). It uses universal electrical input (110Vac
– 250Vac) . Reverses the normal discharge rate and
optimized high frequency patented pulsing reduces
sulfation buildup. Reverse polarity protected. LED
lights indicate the status of each individual battery.
Example: Pro-12 maintaining
recovered 12V batteries.
APPENDIX 3. Lead Acid battery testing, charging and maintenance equipment and corresponding NSNs.
Battery Analyzers
NSN 6130-01-510-9594
Digital Battery Analyzers perform analysis of 12-Volt battery and electrical
system. The above testers are the most prevalent in the military. They are
all classified under the same NSN, and are shown with the oldest model on
the left and newest on the right. The testing algorithms differentiate
battery configurations of AGM (flat and spiral plates), flooded cell and gel
cell batteries and quickly display battery voltage, cold cranking amps,
condition of the battery (Good & Pass, Good & Charge, Charge & Retest)
and state of charge. The new 490PT+ has a built-in printer which can
preserve a written description of the battery's condition. The replacement
paper is available under NSN is 7530-01-357-6852.
Example: 490PT+ being used to analyze a 12 battery.
Mini Battery Load Tester
NSN: 6625-01-463-8499.
The MBT-1 makes checking for good and
bad 12-Volt lead-acid batteries quick and
easy. This weather resistant, mini battery
load tester is small enough to slip in a
pocket. It's simple to use with a fixed post
positive connector and a coil-corded
moveable negative connector. Easy to read
color coded LEDs. Reverse polarity and over
voltage protected
Example: MBT-1 being used
for a 12V battery quick check
APPENDIX 3. Lead Acid battery testing, charging and maintenance equipment and corresponding NSNs.
24-Volt 6.3 Watt
Pulse Solar Charger
NSN 6130-01-487-0035
24-Volt 6.3 Watt - Pulse
Charge Monitor System
NSN: 6130-01-497-0964
24-V 6.3 Watt Pulse Charge system:
Solar or AC charge system.
System NSN: 6130-01-521-1387
AC charge Only NSN: 6130-01-521-1329
Solar Pulse Charge
12 V - 5-Watt Solar
Pulse Charger
NSN 6130-01-446-7154
Monitor System 6.3 Watt.
Plugs into NATO Slave.
NSN: 6130-01-558-5371
12-V PULSE CHARGE SYSTEM:
Solar or AC charge system.
System NSN 6130-01-521-1317
AC charge Only NSN: 6130-01-521-1765