Wire mesh grips provide ? and absorb ? .
a.stress / leverage
b.support / stress
c.vibration / pull
d.weight / pull
The correct answer is: support / stress
Strain relief grips differ from support grips in that they have ? attachments that are easily attached to a junction box or panel.
a.bushing
b.fitting
c.locknut
d.union
The correct answer is: fitting
Mechanically interlocked receptacles allow for the safe connection of power to permanently installed electrical equipment.
Select one:
True
False
The correct answer is 'False'.
What method of overload protection for equipment at the source of power access is
employed within selected Pass & Seymour Legrand switches and interlocked receptacles?
a.Circuit breakers
b.Emergency stop button
c.Fusing
d.Overload relay
The correct answer is: Fusing
The UL 508 listing on non-fusible safety switches allows these products to be used for ? .
a.the avoidance of machine downtime due to the integral blown fuse indication function
b.the overload protection of portable equipment at the source of power access
c.the purpose of a manual motor controller that can be additionally used as a disconnect
switch
The correct answer is: the purpose of a manual motor controller that can be additionally
used as a disconnect switch
The IEC 309 clocking system prevents the mating of plugs and receptacles of different ? and ? ratings.
a.current / resistance
b.current / voltage
c.impedance / resistance
d.impedance / voltage
The correct answer is: current / voltage
The acronym IEC stands for ? .
a.Industrial Electrical Contractor
b.Instrumentation Engineering Consultant
c.International Electrotechnical Commission
d.International Electrical Committee
The correct answer is: International Electrotechnical Commission
The IEC 309 clocking system dictates that the ground contact position for all female connectors and receptacles is based upon a clock face, with the keyway always being located at ? .
a.12:00
b.3:00
c.6:00
d.9:00
The correct answer is: 6:00
Locking plugs and connectors are used in applications where ? is a primary concern.
a.assured/consistent connections
b.child safety
c.environmental conditions
d.high voltage
The correct answer is: assured/consistent connections
Straight blade plugs and connectors come in what two primary amperage ratings?
a.15 A and 20 A
b.16 A and 29 A
c.100 A and 125 A
d.White and ivory
The correct answer is: 15 A and 20 A
What should be done before preparing to install an industrial wiring device?
a.Meet the lockout/tagout requirements of OSHA and NFPA 70E
b.Remove all the light bulbs
c.Strip the wire
d.Tighten the terminal screws of the device
The correct answer is: Meet the lockout/tagout requirements of OSHA and NFPA 70E
Which of the following describes a wiring device utilizing blades that when inserted into
a receptacle establishes a connection between the conductors of the attached flexible cord and the conductors connected to the receptacle?
a.Connector
b.IEC
c.Plug
d.Receptacle
The correct answer is: Plug
Common elements in the construction of an industrial wiring device include ? .
a.assembly screws
b.back body
c.cord grip
d.terminals
e.all of the above
The correct answer is: all of the above
Watertight plugs and connectors are designed for ? environments.
a.cold and exposed
b.dry and hot
c.dusty and splashproof
d.wet and damp
The correct answer is: wet and damp
The maximum voltage and amperage that a wiring device will withstand describes the ? .
a.ideal conditions of installation
b.NEMA rating
c.service rating
d.temperature rating
The correct answer is: service rating