Project Data Collection Information Required for Lighting Calculations LED Lighting Calculation The following information is required to complete a lighting calculation and determine what Bill of Material and other equipment is needed to complete a floodlighting installation according to the indicated requirements. Complete the yellow highlighted fields in Table 1 with the required data to complete the calculations. Use Table 2 as reference for an example of a completed data requirements table. Location of Project o Input Voltage o Drawing should show a clear definition of the areas that have to be illuminated (either shown on the drawing or provide dimensions of the area to light with a clear reference point or otherwise defining the aircraft stand type according to ICAO). Illumination Standards o o o Used to validate the product models required for the project. Main input voltage supported is 120-277V at 50/60 Hz. AutoCAD .dwg or .dxf file of the area to be lite o This information is needed to analyze and define the applicable voltage and current feeds that will be present for the project along with organizing the lighting calculations This information will be used in the lighting calculations to determine equipment required and validate pole/mast height and locations Lux Level and Uniformity standards provide guidance on specific illumination requirements. If compliance with a standard is required, indicate the standard (ICAO, FAA, IES Military etc.). Use of the illuminated area affects the lighting calculations and material required. Aircraft stands require higher illumination standards then general operations areas. Indicate the use in the table. Pole / Mast Information o Retrofitting existing installations: Indicate on the provided drawings the exact position of the poles. Also required is the height of the existing poles and whether there position and heights are already defined or can they be changed. If it can be changed, define the new location and pole height options. o New installations: Indicate on the provided drawings the exact position of the new poles. Also required is the height and type of poles and whether there position and heights are already defined or can it be changed. If it can be changed, define the new location and pole height options. 1|Page Table 1. Data Requirements for Lighting Calculation Project Information & Drawings Illumination Standards Project location Input Voltage AutoCAD drawing Lux Level and uniformity standard Use of Lighted Area Location of poles / masts Indicate the exact location on existing poles/masts on the provided drawing Height / Type Existing pole / mast information Can Pole / Mast Height be changed (Yes / No) If Yes, indicate maximum Height Can Pole / Mast Location be moved (Yes / No) Location of any new poles / masts If yes, indicate on the drawing the range the pole locations can be moved Indicate the location off any new poles/masts on the provided drawing Height / Type New pole / mast information Can new Pole / Mast Height be changed (Yes / No) If Yes, indicate maximum Height Can new Pole / Mast Location be moved Yes or No If yes, indicate on the drawing the range the pole locations can be moved Table 2. Example of Completed Lighting Calculation Table Project Information & Drawings Project location Input Voltage AutoCAD drawing Lux Level and uniformity standard Illumination Standards Use of Lighted Area Location of poles / masts Height / Type Existing pole / mast information Can Pole / Mast Height be changed (Yes / No) 277V, 50Hz Please see provided AutoCAD .dwg file Follow ICAO Annex 14 Aircraft Stands and General Aircraft Operations Areas Shown on provided drawings 20m (60 feet), High Mast with mobile ring No If Yes, indicate maximum Height Can Pole / Mast Location be moved (Yes / No Location of any new poles / masts Height / Type New pole / mast information Airport International, Newtown, City Can new Pole / Mast Height be changed (Yes / No) If Yes, indicate maximum Height Can new Pole / Mast Location be moved Yes Yes, If required to meet ICAO specification See new pole location on provided drawings 20m (60 feet), High Mast with mobile ring Yes 30m (90 feet) No If yes, indicate on the drawing the range the pole locations can be moved 2|Page Table 3. Project Contact Information If you would like the Project Manager to contact customers directly to help expedite resolution of questions and if additional information is needed, please complete contact information table below. Name Contact Name Title Company Email Contact Information Business Phone Mobile Phone Table 4. Freight Estimating Deliveries of the LED Apron Lights are always FCA Cortaccia. Free Carrier means buyer is responsible for transport and expenses from Exworks location. If customer wants to also get estimates on freight costs, please complete the information below. Ship to Location Street Address Ship to Address City State / Province Country ZIP Air Freight [1-2 week delivery estimate] Shipping Preference FCA Carrier Options Ocean Freight [2-4 weeks delivery estimate] Other [Please specify] 3|Page