SECTION 07 95 13 EXPANSION JOINT COVER ASSEMBLIES

SECTION 07 95 13
EXPANSION JOINT COVER ASSEMBLIES
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2003 - 2015 ARCAT, Inc. - All rights reserved
PART 1 GENERAL
1.1
1.2
1.3
SECTION INCLUDES
A.
Interior and exterior foam systems for floors, walls, and ceilings.
B.
Interior joint systems for floors, walls, and ceilings.
C.
Exterior systems.
D.
Compression seals.
E.
Fire barrier systems.
F.
Fire blanket systems.
RELATED SECTIONS
A.
Section 03 30 00 - Cast-in-Place Concrete.
B.
Section 04 22 00.16 - Surface-Bonded Concrete Unit Masonry.
C.
Section 05 21 23 - Steel Joist Girder Framing.
D.
Section 07 62 00 - Sheet Metal Flashing and Trim.
E.
Section 07 90 00 - Joint Protection.
F.
Section 09 26 13 - Gypsum Veneer Plastering.
G.
Section 09 21 16.23 - Gypsum Board Shaft Wall Assemblies.
H.
Section 09 51 00 - Acoustical Ceilings.
I.
Section 09 65 13 - Resilient Base and Accessories.
J.
Section 09 72 23 - Wallpapering.
REFERENCES
A.
Underwriters Laboratories:
1.
UL 2079 - Tests for Fire Resistance of Building Joint Systems.
2.
UL 263 - Fire Tests of Building Construction and Materials.
B.
ASTM International:
1.
ASTM A 176 - Standard Specification for Stainless and Heat-Resisting Chromium
07 95 13-1
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
1.4
Steel Plate, Sheet, and Strip.
ASTM B 209 - Standard Specification for Aluminum and Aluminum Alloy Sheet and
Plate.
ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded
Bars, Rods, Wire, Shapes, and Tubes.
ASTM C177 - Standard Test Method for Steady-State Heat Flux Measurements and
Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus.
ASTM D 624 - Standard Test Method for Tear Strength of Conventional Vulcanized
Rubber and Thermoplastic Elastomers.
ASTM D 1056 - Standard Specification for Flexible Cellular Materials Sponge of
Expanded Rubber.
ASTM D 2000 - Standard Classification System for Rubber Products in Automotive
Applications.
ASTM D 2240 - Standard Test Method for Rubber Property - Durometer Hardness.
ASTM D 3575 - Standard Test Methods for Flexible Cellular Made from Olefin
Polymers.
ASTM E119 - Standard Test Methods for Fire Tests of Building Construction and
Materials.
ASTM E 814 - Standard Test Method for Fire Tests of Penetration Firestop Systems.
ASTM E1399 - Cyclic Movement and Measuring of Minimum/Maximum Joint Widths
of Architectural Joint Systems.
ASTM E 1966 - Standard Test Method for Fire Resistive Joint Systems.
SUBMITTALS
A.
Submit under provisions of Section 01 30 00 - Administrative Requirements.
B.
Product Data: For each type of expansion joint cover assembly, provide the following.
1.
Manufacturer's technical data sheets and product specifications.
2.
Installation instructions.
3.
Detail drawings
C.
Shop Drawings:
1.
Shop drawing submittal should include Placement drawings which show line
diagrams, elevations, sections, details and layout for each joint length.
2.
These drawings must include a Joint System Schedule which denotes specific
information for each joint system in tabular form.
3.
The tables should include the model number for each joint system item, location as
cross-referenced in the drawings, nominal joint width and system movement
capability, material colors and finishes, fire-resistive ratings, design loading criteria
and any other options.
D.
Samples for Verification: 2 samples, minimum 5 inch (127 mm) long, of each type of product,
system and assembly specified herein.
E.
Product Test Reports:
1.
Manufacturer will provide independent evaluations by a recognized testing agency.
2.
In the case of fire-rated applications, the Test Reports should include Fire Test
Certification Listing Documents.
F.
Fire-Rated Joint Assemblies: Where indicated in the drawings, provide architectural joint
system and fire-barrier assemblies identical to those depicted and tested for fire resistance
per ASTM E 1966 or UL 2079. The following are some of the recognized independent
laboratories conducting tests of fire-resistive systems:
1.
Underwriters Laboratories Inc., Northbrook, IL; (847) 272-8800; www.ul.com.
2.
Omega Point Laboratories, Elmendorf, TX; (210) 635-8100; www.opl.com.
3.
Southwest Research Institute, San Antonio, TX; (210) 522-2311; www.swri.com.
07 95 13-2
4.
5.
6.
1.5
1.6
1.7
Factory Mutual, Norwood, MA; (781) 762-4300; www.fmglobal.com.
Intertek Testing Services, Antioch, CA; (925) 756-6606;www.itsqs.com.
Guardian Fire Testing Laboratories, Tonawanda, NY; (716) 835-6880;
gfli@earthlink.net
QUALITY ASSURANCE
A.
Manufacturer Qualifications: Company with not less than 5 years of experience in the
design, engineering, and fabrication of expansion joint cover assemblies.
B.
Installer Qualifications: Firm acceptable to manufacturer and with not less than 3 years of
successful experience in the installation of systems similar to those required for this project.
C.
Single Source Requirements:
1.
To the greatest extent possible, architectural joint systems are to be supplied from a
single manufacturer.
2.
Where fire-rated joint systems are required, both the joint system and fire barrier
assembly must be obtained from a single manufacturer.
3.
The total system, mechanical joint and fire barrier, must be as shown in the Fire Test
Certification Listing Documents.
DELIVERY, STORAGE, AND HANDLING
A.
Protect finished metal surfaces with temporary protective covering.
B.
Deliver assemblies to project site in manufacturer's clean, unopened cartons or crates.
C.
Store components in original containers in a clean, dry location until installed. Protect from
weather, constructions activities and damage.
WARRANTY
A.
Manufacturer's Standard Warranty: For architectural joint system products.
1.
Warranty Period: 5 years.
2.
Warranty Period: Extended warranty.
PART 2 PRODUCTS
2.1
2.2
MANUFACTURERS
A.
Acceptable Manufacturer: Inpro, which is located at: S80 W18766 Apollo Dr.; Muskego, WI
53150; Toll Free Tel: 800-222-5556; Tel: 262-679-9010; Fax: 262-679-9127; Email:request
info (jjohnson@inprocorp.com); Web:www.inprocorp.com
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section 01 60
00 - Product Requirements.
EXPANSION JOINT COVER ASSEMBLIES - GENERAL
A.
Joint Movement: Design and fabricate expansion joint cover assemblies to permit the
following amount of movement without disengagement or other damage:
1.
Horizontal: Maximum x-axis joint movement of _____ inches (____ mm).
2.
Vertical: Maximum y-axis joint movement of _____ inches (___ mm).
3.
Lateral: Maximum z-axis joint movement of _____ inches (____ mm).
B.
Allowable Loading: Design and fabricate expansion joint cover assemblies to accommodate
07 95 13-3
the following loading without distortion or damage:
1.
Uniform Loading: Maximum 50 psf (2394 Pa).
2.
Uniform Loading: Maximum 100 psf (4788 Pa).
3.
Uniform Loading: Maximum 200 psf (9576 Pa).
4.
Concentrated Loading: Maximum 300 pounds (1334 N)
5.
Concentrated Loading: Maximum 2,000 pounds (8896 N).
6.
Maximum Allowable Stress:
a.
Aluminum Extrusions: 12,000 psi (82.7 MPa).
b.
Aluminum Plate: 28,000 psi (193 MPa).
c.
Aluminum Sheet: 16,000 psi (110.3 MPa).
d.
Stainless Steel Plate: 36,000 psi (248 MPa).
7.
Maximum Deflection: 1/16 inch (1.6 mm).
8.
Maximum Deflection: 1/8 inch (3.2 mm).
2.3
C.
Expansion Joint Fire Barrier Assemblies:
1.
Compliance: Rated architectural joint systems and fire-barrier assemblies must
comply with applicable requirements of UL 2079 and ASTM E 1966.
a.
Provide minimum 2 hour rating, or not less than fire rating of adjacent
construction.
b.
Hose Stream Test: Wall/wall and wall/ceiling fire-barrier assemblies shall be
subjected to hose stream testing.
2.
Compliance: Rated architectural joint systems and fire-barrier assemblies must
comply with applicable requirements of ANSI/UL 263, ASTM E 119 and ASTM E 814.
a.
Hose Stream Test: Provide 950 or F520 Fire Blanket System to UL2079.
Wall/wall and wall/ceiling fire-barrier assemblies shall be subjected to hose
stream testing.
D.
Factory fabricate special transitions and corner fittings as required by project conditions.
Miter and weld elastomeric seals as applicable.
E.
Aluminum: Alloy 6063-T6, in accordance with ASTM B 221; mill finish.
F.
Aluminum: Alloy 5052-H32, in accordance with ASTM B 221; mill finish.
G.
Stainless Steel: ASTM A 176, Type 430, 16 gage, satin finish.
H.
Stainless Steel: Type 304, 2B finish.
I.
EPDM: ASTM D 2000.
J.
Vapor Barrier/Backseal: 40 mils thick PVC or 45 mils thick Fabric Reinforced EPDM.
K.
Provide appropriate fasteners, adhesives, and accessories as required to properly complete
expansion joint cover installation, prepackaged with expansion joint covers in maximum
lengths possible.
INTERIOR AND EXTERIOR FOAM SYSTEMS FOR FLOORS, WALLS, AND CEILINGS
A.
Materials:
1.
Open Cell Foam (1200 or 1175): Pre-compressed, impregnated, polyurethane foam.
2.
Closed Cell Foam (1100, 1150, or 1250): Low density, impermeable, ethylene vinyl
acetate (EVA)(1150 only), nitrogen blown (1100 only), polyethylene, or stabilized
polymer (1250 only) material.
3.
Epoxy: High Strength two-part 100% solid, moisture insensitive epoxy.
4.
Paint (1100 and 1150 only): Acrylic, elastomeric, non-cracking interior and exterior
grade.
5.
Face Sealant (1175, 1200, and 1250): Color matched silicone based (pick resistant
07 95 13-4
6.
7.
8.
where required).
Adhesive Sealant (1200 and 1250): Construction grade silicone sealant, supplied by
others.
Silicone Coating (1200 and 1250): Applied on exposed surface(s) of foam.
Urethane Coating (1175, 1200, and 1250): Pick resistant optional coating applied on
exposed surface of foam.
B.
Product: JointMaster's 1100 Series - Closed Cell Foam:
1.
Pre-formed, cross linked nitrogen blown expansion joint foam.
2.
High heat resistance with a UV inhibitor.
3.
Inherent sound attenuation qualities.
4.
Suitable for horizontal and vertical seismic conditions.
5.
ColorMatch (JPR007) paint available.
6.
Available in continuous, uninterrupted lengths of 40 lf (12 lm) minimum.
7.
Beveled edges standard for joint widths 4 inches and up, installed with epoxy.
8.
DOT approved conforming to ASTM D-1056, Type 2, Class B, Grade 3.
9.
Foam seal shall meet the following requirements:
a.
Nominal Density ASTM D3575-W: 2.0 pcf +/- 0.3.
b.
Compressive (+/-1) ASTM D3575-D: 11.5 psi @ 25% and 22 psi @ 50%.
c.
Elongation ASTM D3575-T: 200% +/- 10%.
d.
Tensile Strength ASTM D3575-T: 125 psi +/- 12 psi.
e.
Tear Strength ASTM D3575-G: 17.5 pli +/- 3 pli.
f.
Compression Set (22 hr @ 50%) ASTM D3575-B: 9% @ 24 hr rcvy.
g.
Water Absorption ASTM D3575-L: < 0.003 lb/ft2 3% vol/vol.
C.
Product: JointMaster's 1150 Series - Closed Cell Foam:
1.
Pre-formed, cross linked polyethylene with EVA.
2.
Chemical and solvent resistant foam seal with a UV inhibitor.
3.
Inherent sound attenuation qualities.
4.
Suitable for horizontal and vertical seismic conditions.
5.
ColorMatch (JPR007) paint available.
6.
Available in continuous, uninterrupted lengths of 40 lf (12 lm) minimum.
7.
Beveled edges standard for joint widths 4 inches and up, installed with epoxy.
8.
DOT approved conforming with ASTM D-1056, Type 2, Class B, Grade 2 and
NYSDOT 705.08 TYPE I and TYPE II.
9.
Foam seal shall meet the following requirements:
a.
Nominal Density ASTM D3575-W: 3.0 pcf max.
b.
Compressive (+/-1): ASTM D3575-D: 5 psi @ 25% and 14 psi @ 50%.
c.
Elongation ASTM D3575-T: 275% +/- 10%.
d.
Tensile Strength ASTM D3575-T: 70 psi +/- 12 psi.
e.
Tear Strength ASTM D3575-G: 12 pli +/- 3 pli.
f.
Compression Set (22 hr @ 50%) ASTM D3575-B: 14.5% @ 24 hr rcvy.
g.
Water Absorption ASTM D3575-L: < 0.003 lb/ft2 3% vol/vol max.
D.
Product: JointMaster's 1175 Series - Open Cell Foam:
1.
Pick resistant urethane joint sealant on the exterior face, offered in gray only.
2.
Intended for horizontal seismic applications.
3.
State and Federal DOT approved.
4.
Foam seal shall meet the following requirements:
a.
Density: 10 lb/cu. Ft (160 kg/cubic meters).
b.
Thermal Resistance (ASTM C518): 3.3 hr - degree F-ft2/Btu.
c.
UV Resistance: Excellent.
d.
Temperature Stability Range: -40 degree F to 185 degree F.
e.
Resistance to Compression Set (ASTM 3574): Max 2.5%.
f.
Shear Strength: Min. 8N/cm2.
g.
Thermal Conductivity: 0.05W/m. degree C.
07 95 13-5
h.
i.
j.
2.4
Tensile Strength (ASTM 3574): Meets 21 psi min.
Ultimate Elongation (ASTM 3574): 125% +/- 20%.
Mildew Resistance: Excellent.
E.
Product: JointMaster's1200 Series - Open Cell Foam:
1.
Foam joint sealant comes pre-compressed and is non-drying, non-shrinking, selfhealing, and self-expanding.
2.
Exposed surface(s) is silicone coated with single, double, or triple faced configurations
available.
3.
Excellent sound attenuation qualities (STC Rating = 52).
4.
Suitable for vertical seismic applications.
5.
Available in thirteen standard colors, custom color available.
6.
Foam seal shall meet the following requirements:
a.
Density: 10 lbs per cubic foot (130 to 160 Kg per cubic meter).
b.
Thermal Conductivity: 0.05 w per square meter degree C.
c.
Temperature Stability Range: Short term: Minus 40 degrees F to 185 degrees F
(Minus 40 C to 85 degrees C).
d.
Tensile Strength: 21 PSI minimum per ASTM 3574.
e.
Elongation: 125 percent plus or minus 20 percent per ASTM 3574.
f.
Compression Set: 2.5 percent maximum.
g.
Resistance to Aging: Excellent.
h.
Staining: None.
i.
Mildew Resistance: Excellent.
j.
Outdoor Exposure: Excellent.
k.
Shelf Life: 2 years.
l.
Thickness: 1 inch to 8 inches).
m.
Color: Dow 790 silicone colors.
F.
Product: JointMaster's1250 Series - Closed Cell Foam:
1.
Foam joint sealant is field compressed and is non-drying, non-shrinking, self-healing,
and self-expanding.
2.
Exposed surface(s) is silicone coated with single faced configuration only.
3.
Excellent sound attenuation qualities (STC Rating = 48).
4.
Suitable for vertical seismic applications.
5.
Available in thirteen standard colors, custom color available.
6.
Foam seal shall meet the following requirements:
a.
Density: 10 lbs per cubic foot (160 Kg per cubic meter).
b.
Thermal Conductivity: R-4 ASTM C177.
c.
Water Absorption: < .02lbs/cubic feet ASTM D3575.
d.
Tensile Strength: 120 PSI minimum per ASTM 3575.
e.
Elongation: 250 percent ASTM 3575.
f.
Tear Resistance: 21.5 lbs/in. ASTM D624.
g.
Resistance to Aging: Excellent.
h.
Staining: None.
i.
Mildew Resistance: Excellent.
j.
Outdoor Exposure: Excellent.
k.
Shelf Life: 2 years.
l.
Thickness: 1 inch to 12 inches).
m.
Durometer Hardness: Shore A 15pts. ASTM D2240.
n.
Color: Dow 790 silicone colors.
INTERIOR JOINT SYSTEMS FOR FLOORS, WALLS, AND CEILINGS
A.
Expansion Joint Cover Assemblies: JointMaster 100 Series; aluminum frame with
continuous dual durometer or pleated Santoprene seal.
1.
Elastomeric Seal: Dual durometer santoprene with 60 Shore A and 90 Shore A or
07 95 13-6
2.
3.
4.
5.
pleated santoprene seal with durometer of 70 shore A including a UV inhibitor. No
neoprene substitutions allowed to reduce negative environmental impacts. Colors
shall be selected from manufacturer's standard range - Black, Gray, Beige, Off-White
and Bright White. Custom colors as scheduled or required as noted on the drawings.
Design: Dual durometer flat seal shall maintain inherent dimensional stability and
include structural spine inserts (where applicable) allowing for additional load
resistance. Bellows depth not to exceed 5/8 inch (16 mm). Wall thickness not less
than 1/8 inch (3 mm).
Application: Floor Systems - Recessed/Flush Mount, Floor/Floor or Floor/Wall.
a.
Frame Type: Recessed frame, flush mount floor.
1)
Product: JointMaster-101-A01 (floor/floor) as manufatured by Inpro.
Accepts all floor finishes.
2)
Product: Combination Recessed and Flush Frame; JointMaster-120-A01
(floor/floor) as manufatured by Inpro. Accepts all floor finishes.
3)
Frame Height: 1 inch (25 mm).
4)
Frame Height: 1-1/2 inches (38 mm).
5)
Frame Height: 2 inches (50 mm).
b.
Frame Type: Recessed frame, corner.
1)
Product: JointMaster-101-A02 (floor/wall) as manufatured by Inpro.
Accepts all floor finishes.
2)
Product: Combination Recessed and Flush Frame: JointMaster-120-A02
(floor/wall) as manufatured by Inpro. Accepts all floor finishes.
3)
Recessed Depth of Wall Frame: 3/8 inch (9.5 mm).
4)
Recessed Depth of Wall Frame: 5/8 inch (16 mm).
5)
Recessed Depth of Wall Frame: 1 inch (25 mm).
6)
Frame Height: 1 inch (25 mm).
7)
Frame Height: 1-1/2 inches (38 mm).
8)
Frame Height: 2 inches (50 mm).
Application: Floor Systems - Surface Mount, Floor/Floor or Floor/Wall
a.
Frame Type: Surface mounted frame; JointMaster-103-A01 (floor/floor) as
manufatured by Inpro. Accepts 1/8 inch (3 mm) VCT flooring.
b.
Frame Type: Surface mounted frame; JointMaster-103-A02 (floor/wall) as
manufatured by Inpro. Accepts 1/8 inch (3 mm) VCT flooring.
c.
Frame Type: Surface mounted frame; JointMaster-104-A01 (floor/floor) as
manufatured by Inpro.Accepts all floor finishes.
d.
Frame Type: Surface mounted frame; JointMaster-104-A02 (floor/wall) as
manufatured by Inpro. Accepts all floor finishes.
e.
Frame Type: Surface mounted frame; JointMaster-105-A01 (floor/floor) as
manufatured by Inpro.
f.
Frame Type: Surface mounted frame; JointMaster-105-A02 (floor/wall) as
manufatured by Inpro.
g.
Frame Type: Surface mounted frame; JointMaster-106-A01 (floor/floor) as
manufatured by Inpro. Accepts 1/4 inch (6 mm) carpet flooring.
h.
Frame Type: Surface mounted frame; JointMaster-106-A02 (floor/wall) as
manufatured by Inpro. Accepts 1/4 inch (6 mm) carpet flooring.
1)
Joint Width: 1 inch (25 mm).
2)
Joint Width: 2 inches (50 mm).
3)
Joint Width: 3 inches (75 mm).
Application: Tile Joint Movement System.
a.
Frame Type: Floor Systems: Recessed mount frame with integral seal for
tile/terrazzo floors, floor/floor - JointMaster J55 - Continuous aluminum sides
with integral movement seal. Mill finish.
1)
J55-10/XX. Sightline: 10 mm. Height: 15 mm, 20 mm, 25 mm, 30 mm, 35
mm and 40 mm. Provide as scheduled or required. Refer to drawings.
b.
Frame type: Wall Systems: Recessed mount frame with integral seal for tile
walls, wall/wall - JointMaster J55 - Continuous aluminum sides with integral
07 95 13-7
6.
7.
8.
9.
10.
11.
movement seal. Mill finish.
1)
J55-10/XX. Sightline: 10 mm. Height: 15 mm, 20 mm, 25 mm, 30 mm, 35
mm and 40 mm. Provide as scheduled or required. Refer to drawings.
Application: Floor Systems - New to Existing (Renovation), Floor/Floor or Floor/Wall.
a.
Frame Type: New floor to old floor, combination recessed and surface mounted
frame; JointMaster-107-A01 as manufatured by Inpro. Accepts all floor finishes.
b.
Frame Type: Combination recessed and surface mounted frame; JointMaster108-A01 as manufatured by Inpro.
c.
Frame Type: New floor to old floor; combination recessed and surface mounted
frame; JointMaster-109-A01 as manufatured by Inpro. Accepts 1/4 inch (6 mm)
minimum depth carpet flooring.
d.
Joint Width: 1 inch (25 mm).
e.
Joint Width: 2 inches (50 mm).
f.
Joint Width: 3 inches (75 mm).
g.
Joint Width: 1 inch (25 mm).
h.
Joint Width: 2 inches (50 mm).
i.
Joint Width: 3 inches (75 mm).
j.
Provide optional stainless steel decorative caps.
k.
Provide optional brass decorative caps.
l.
Provide optional integral vinyl vapor barrier.
Application: Drywall finish, exposed frame, natural anodized finish.
a.
Frame Type: Flat; JointMaster-112-A07 (wall/wall and ceiling/ceiling) as
manufatured by Inpro. Accepts 5/8 inch (16 mm) drywall finish.
b.
Frame Type: Corner; JointMaster-112-A09 (wall/corner and wall/ceiling) as
manufatured by Inpro. Accepts 5/8 inch (16 mm) drywall finish.
c.
Joint Width: 1 inch (25 mm).
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
Application: Drywall finish; concealed frame, concealed by joint compound.
a.
Frame Type: Flat: JointMaster-113-A07 (wall/wall and ceiling/ceiling) as
manufatured by Inpro. Accepts drywall finish.
b.
Frame Type: Corner; JointMaster-113-A09 (wall/corner and wall/ceiling) as
manufatured by Inpro. Accepts drywall finish.
c.
Joint Width: 1 inch (25 mm).
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
Application: Wall/ceiling, surface mounted exposed frame.
a.
Frame Type: Flat: JointMaster-104-A07 (wall/wall and ceiling/ceiling) as
manufatured by Inpro. Accepts all floor finishes.
b.
Frame Type: Corner: JointMaster-104-A09 (wall/corner and wall/ceiling) as
manufatured by Inpro. Accepts all floor finishes.
c.
Joint Width: 1 inch (25 mm).
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
Application: Acoustic ceiling, concealed frame, designed for installation in suspended
acoustical ceiling.
a.
Frame Type: JointMaster-115-A24 (ceiling/ceiling) as manufatured by Inpro.
Accepts acoustical ceiling tile only.
b.
Frame Type: JointMaster-115-A18 (ceiling/wall) as manufatured by Inpro.
Accepts acoustical ceiling tile only.
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 3 inches (75 mm).
e.
Joint Width: 4 inches (100 mm).
f.
Joint Width: 5 inches (125 mm).
g.
Joint Width: 6 inches (150 mm).
Application: Wall/ceiling, recessed frame, flat, frame recessed 5/8 inch (16 mm);
07 95 13-8
a.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
B.
Frame Type: JointMaster-101-A07 (wall/wall and ceiling/ceiling) as
manufatured by Inpro. Accepts 5/8 inch (16 mm) finishes.
b.
Joint Width: 1 inch (25 mm).
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 3 inches (75 mm).
e.
Provide optional stainless steel decorative caps.
f.
Provide optional brass decorative caps.
Application: Wall/ceiling, recessed frame, corner.
a.
Frame Type: One flush wall frame; JointMaster-101-A09 (wall/corner and
wall/ceiling) as manufatured by Inpro. accepts 1/4 inch (6 mm) minimum depth
carpet flooring.
b.
Joint Width: 1 inch (25 mm).
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 3 inches (75 mm).
Application: Interior Wall Systems - Recessed/Flush Mount, Wall/Wall (and
Ceiling/Ceiling) or Wall/Corner (and Ceiling/Wall).
a.
Elastomeric seal, continuous Santoprene seal retained by continuous aluminum
frame at each side of joint.
b.
Product: JointMaster-611-A07 or A09 as manufatured by Inpro. Pleated seal
system suitable for all wall finishes.
c.
Product: JointMaster-612-A07 or A09 as manufatured by Inpro. Pleated seal
with intermediate frame and center bar system suitable for all wall finishes.
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
f.
Joint Width: 4 inches (100 mm).
g.
Joint Width: 6 inches (150 mm).
h.
Joint Width: 8 inches (200 mm).
i.
Joint Width: 12 inches (300 mm).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Expansion Joint Cover Assemblies: JointMaster 200 Series Recessed Modular Floor
System.
1.
Elastomeric Seal: Dual durometer santoprene with 60 Shore A and 90 Shore A or
pleated santoprene seal with durometer of 70 shore A including a UV inhibitor. No
neoprene substitutions allowed to reduce negative environmental impacts. Colors to
be selected from manufacturer's standard range - Black, Gray, Beige, Off-White and
Bright White. Custom colors available.
2.
Design: Dual durometer flat seal shall maintain inherent dimensional stability and
include structural spine inserts (where applicable) allowing for additional load
resistance. Bellows depth not to exceed 5/8 inch (16 mm). Wall thickness not less
than 1/8 inch (3 mm).
a.
Allowable load on floor joint cover plate shall be 500 lb (227 kg) for standard
07 95 13-9
3.
4.
loads, 1000 lb (454 kg) for moderate loads, and 2000 lb (907 kg) for heavy duty
loads.
b.
Centering Bars, where applicable on systems 4 inches (102 mm) and larger,
shall be fabricated from zinc coated steel.
c.
Spring Clips, where applicable in 2 inches (51 mm) systems, shall be formed
from spring steel.
d.
Floor/Floor: JointMaster-221-A01 as manufatured by Inpro.
1)
Plates: Flush aluminum plates suitable for all floor finishes.
2)
Seals: Santoprene seals.
e.
Floor/Floor: JointMaster-222-A01 as manufatured by Inpro.
1)
Pans: 1/8 inch (3 mm) recessed aluminum pans to accept 1/8 inch (3
mm) floor finishes..
2)
Seals: Dual Santoprene seals.
f.
Floor/Floor: JointMaster-223-A01 as manufatured by Inpro.
1)
Pans: 3/8 inch (9.5 mm) recessed aluminum pans to accept 3/8 inch (9.5
mm) floor finishes.
2)
Seals: Dual Santoprene seals.
3)
Provide optional stainless steel decorative caps.
4)
Provide optional brass decorative caps.
g.
Floor/Wall: JointMaster-223-A02 as manufatured by Inpro.
1)
Pans: 3/8 inch (9.5 mm) recessed aluminum half pans.
2)
Seals: Single Santoprene seal.
3)
Provide optional stainless steel decorative caps.
4)
Provide optional brass decorative caps.
4 inch (100 mm) Joint Width: Frame height 5/8 inch (16 mm) with steel centering bar:
a.
Floor/Floor: JointMaster-221-A01 as manufatured by Inpro.
1)
Plates: Flush aluminum plates suitable for all floor finishes.
2)
Seals: Dual Santoprene seals.
b.
Floor/Floor: JointMaster-222-A01 as manufatured by Inpro.
1)
Pans: 1/8 inch (3 mm) recessed aluminum pans to accept 1/8 inch (3
mm) floor finishes..
2)
Seals:: Dual Santoprene seals.
c.
Floor/Floor: JointMaster-223-A01 as manufatured by Inpro.
1)
Pans: 3/8 inch (9.5 mm) recessed aluminum pans to accept 3/8 inch (9.5
mm) floor finishes.
2)
Seals: Dual Santoprene seals.
3)
Provide optional stainless steel decorative caps.
4)
Provide optional brass decorative caps.
d.
Floor/Wall: JointMaster-223-A02 as manufatured by Inpro.
1)
Pans: 3/8 inch (9.5 mm) recessed aluminum half pans to accept 3/8 inch
(9.5 mm) floor finishes.
2)
Seals: Single Santoprene seal.
3)
Provide optional stainless steel decorative caps.
4)
Provide optional brass decorative caps.
6 inch (150 mm) Joint Width: With steel centering bar.
a.
Floor/Floor: JointMaster-221-A01 as manufatured by Inpro.
1)
Plates: Flush aluminum plates suitable for all floor finishes.
2)
Seals: Dual Santoprene seals.
b.
Floor/Floor: JointMaster-222-A01 as manufatured by Inpro.
1)
Pans: 1/8 inch (3 mm) recessed aluminum pans to accept 1/8 inch (3
mm) floor finishes..
2)
Seals: Dual Santoprene seals.
c.
Floor/Floor: JointMaster-223-A01 as manufatured by Inpro.
1)
Pans: 3/8 inch (9.5 mm) recessed aluminum pans to accept 3/8 inch (9.5
mm) floor finishes.
2)
Seals: Dual Santoprene seals.
07 95 13-10
5.
6.
7.
8.
9.
10.
11.
12.
13.
C.
3)
Provide optional stainless steel decorative caps.
4)
Provide optional brass decorative caps.
d.
Floor/Wall: JointMaster-223-A02 as manufatured by Inpro.
1)
Pans: 3/8 inch (9.5 mm) recessed aluminum half pans.
2)
Seals: Single Santoprene seal.
3)
Provide optional stainless steel decorative caps.
4)
Provide optional brass decorative caps.
e.
Provide optional continuous EPDM vapor barrier.
f.
Provide optional Reactofire fire blanket system.
Wall/Ceiling Systems - Recessed/Flush Mount, Wall/Wall (and Ceiling/Ceiling) or
Wall/Corner (and Ceiling/Wall).
a.
221-A07 or A09, flush plate.
b.
223-A07 or A09, center pan recessed to accept 3/8 inch (9.5 mm) drywall.
c.
233-A07 or A09, center pan recessed to accept 3/8 inch (9.5 mm) drywall,
spring reset.
d.
243-A07 or A09, pleated seal, center pan recessed to accept 3/8 inch (9.5 mm)
drywall, spring reset.
e.
253-A07 or A09, frame depth 5/8 inch (16 mm), flush plate with no seals, spring
reset.
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Expansion Joint Cover Assemblies: JointMaster 800 Series.
1.
Design: Standard cover plate system profiles.
a.
Allowable load on floor joint cover plate shall be 500 lb (227 kg) for standard
loads, 1000 lb (454 kg) for moderate loads, and 2000 lb (907 kg) for heavy duty
loads.
b.
Spring Clips (804 only): Stainless steel required.
c.
Gaskets (811 only): Vinyl gasket required.
2.
Application: Floor Cover Plate, continuous aluminum plate fastened on one side of
joint.
a.
Product: JointMaster-801-A01 (floor/floor) as manufatured by Inpro. Cover plate
with beveled edges, suitable for all floor finishes.
b.
Product: JointMaster-801-A02 (floor/wall) as manufatured by Inpro. Cover plate
with beveled edges, suitable for all floor finishes.
c.
Joint Width: 1 inch (25 mm).
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
f.
Application: Floor plate to floor covering, continuous aluminum plate fastened
on one side of joint and designed to accommodate flooring on opposite side.
g.
Product: JointMaster-802-A01 (floor/floor) as manufatured by Inpro. Cover plate
with minimal sightline, accepts 1/8 inch (3 mm), 1/4 inch (6 mm) and 3/8 inch
(9.5 mm) floor finishes.
07 95 13-11
3.
4.
5.
6.
7.
8.
h.
Joint Width: 2 inches (50 mm).
i.
Frame Flooring Thickness: 1/8 inch (3 mm).
j.
Frame Flooring Thickness: 1/4 inch (6 mm).
k.
Frame Flooring Thickness: 3/8 inch (10 mm).
Application: Spring clip floor cover plate, continuous aluminum plate held in place by
stainless steel spring clips concealed within joint.
a.
Product: JointMaster-804-A01 (floor/floor) as manufatured by Inpro. Suitable for
all floor finishes.
b.
Product: JointMaster-804-A02 (floor/wall) as manufatured by Inpro. Suitable for
all floor finishes.
c.
Product: JointMaster-804-A07 (wall/wall and ceiling/ceiling) as manufatured by
Inpro. Suitable for all floor finishes.
d.
Product: JointMaster-804-A09 (wall/corner and wall/ceiling) as manufatured by
Inpro. Suitable for all floor finishes.
e.
Joint Width: 1 inch (25 mm).
f.
Joint Width: 1-1/2 inches (38 mm).
g.
Joint Width: 2 inches (50 mm).
Application: Surface mount variable degree plate for walls/ceilings, continuous
aluminum variable degree plate with continuous vinyl gasket and adjustable retainer.
a.
Product: JointMaster-811-A07 (wall/wall and ceiling/ceiling) as manufatured by
Inpro.
b.
Product: JointMaster-811-A09 (wall/corner or wall/ceiling) as manufatured by
Inpro.
c.
Joint Width: 1 inch (25 mm).
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
f.
Joint Width: 4 inches (100 mm).
Application: Acoustical ceilings, variable degree, continuous dual durometer pleated
vinyl seal designed for pop riveting to acoustical ceiling tees and fastening to wall.
a.
Product: JointMaster-821-V24 (ceiling/ceiling) as manufatured by Inpro.
b.
Product: JointMaster-821-V23 (ceiling/wall) as manufatured by Inpro.
c.
Joint Width: 1 inch (25 mm).
d.
Joint Width: 2 inches (50 mm).
Application: Floor cover plate, hinged aluminum plate fastened on one side of joint.
a.
Product: JointMaster 806-A01 (floor/floor) as manufatured by Inpro. Serrated
and hinged cover plate with leading edge ratio not to exceed 1:8 (7 degrees),
suitable for all floor finishes.
b.
Product: JointMaster 806-A02 (floor/wall) as manufatured by Inpro. Serrated
and hinged cover plate with leading edge ratio not to exceed 1:8 (7 degrees),
suitable for all floor finishes.
c.
Product: JointMaster 807-A01 as manufatured by Inpro. Hinged cover plate
with minimal sightline, accepts 1/8 inch (3mm) or 3/8 inch (9.5 mm).
d.
Product: JointMaster 808-A01 as manufatured by Inpro. Serrated cover plate
with beveled edges, suitable for all floor finishes.
e.
Joint Width: 2 inches (50 mm).
f.
Joint Width: 3 inches (76 mm).
g.
Joint Width: 4 inches (100 mm).
h.
Joint Width: 6 inches (152 mm)
i.
Joint Width: 8 inches (204 mm) (806 only).
j.
Joint Width: 10 inches (254 mm) (806 only).
k.
Joint Width: 12 inches (306 mm) (806 only).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
07 95 13-12
9.
10.
11.
12.
13.
14.
D.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Seismic Joint Cover Assemblies: Glide plate type; JointMaster 300 Series.
1.
Design: Thermoplastic vinyl gaskets provided to reduce wear on the underside of the
glide plate and act as a sound dampener. Vinyl Gasket (Series 300, 304 and 312).
Color - Black.
a.
Allowable load on floor joint cover plate shall be 500 lb (227 kg) for standard
loads, 1000 lb (454 kg) for moderate loads, and 2000 lb (907 kg) for heavy duty
loads.
2.
Application: Floor, "No Bump" glide plate, aluminum frame and continuous aluminum
glide plate with crenellated surface.
a.
Frame Types: Recessed frame, JointMaster-300-A01 (floor/floor) as
manufatured by Inpro. Suitable for all floor finishes.
b.
Frame Types: Recessed frame, JointMaster-300-A02 (floor/wall) as
manufatured by Inpro. Suitable for all floor finishes.
c.
Frame Types: Recessed frame, JointMaster-304-A01 (floor/floor) as
manufatured by Inpro. Accepts 1/8 inch (3 mm) floor finishes.
d.
Frame Types: Recessed frame, JointMaster-304-A02 (floor/wall) as
manufatured by Inpro. Accepts 1/8 inch (3 mm) floor finishes.
e.
Frame Types: Surface mounted frame, JointMaster-312-A01 (floor/floor) as
manufatured by Inpro. System does not install flush, suitable for all floor
finishes.
f.
Frame Types: Surface mounted frame, JointMaster-312-A02 (floor/wall) as
manufatured by Inpro. System does not install flush, suitable for all floor
finishes.
g.
Frame Types: New to old floor, JointMaster-320-A01 combination recessed and
surface mounted aluminum frame as manufatured by Inpro.
h.
Joint Width: 1 inch (25 mm).
i.
Joint Width: 2 inches (50 mm).
j.
Joint Width: 3 inches (75 mm).
k.
Joint Width: 4 inches (100 mm).
l.
Joint Width: 6 inches (150 mm).
3.
Application: Recessed frame/flush frame for use with vinyl wall covering.
a.
Product: JointMaster 318-A07 (wall/wall) as manufatured by Inpro.
b.
Product: JointMaster 318-A09 (wall/corner) as manufatured by Inpro.
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 3 inches (75 mm).
4.
Application: Carpeted floors, recessed aluminum frame with continuous aluminum
pivot and spring steel support plate designed for minimum visual impact in carpeted
areas;
a.
Product: JointMaster-316-A01 (floor/floor) as manufatured by Inpro.
b.
Product: JointMaster-316-A02 (floor/wall) as manufatured by Inpro.
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 3 inches (75 mm).
5.
Walls/Ceilings: Recessed drywall aluminum frame with vinyl gaskets, with continuous
aluminum center plate; JointMaster-300-A07 (wall/wall) and -300-A09 (wall/corner).
a.
Joint Width: 1 inch (25 mm).
07 95 13-13
6.
7.
8.
9.
10.
11.
12.
13.
E.
b.
Joint Width: 2 inches (50 mm).
c.
Joint Width: 3 inches (75 mm).
d.
Joint Width: 4 inches (100 mm).
e.
Joint Width: 6 inches (150 mm).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Seismic Joint Cover Assemblies: Center plate type; JointMaster 400 Series.
1.
Design: aluminum or stainless steel frame with continuous tapered plate held in place
by steel centering bar with compression spring assembly.
a.
Centering Bars (where required) shall be fabricated from zinc coated steel.
b.
Allowable load on floor joint cover plate shall be 500 lb (227 kg) for standard
loads, 1000 lb (454 kg) for moderate loads, and 2000 lb (907 kg) for heavy duty
loads.
2.
Application: Recessed/Flush Mount, Floor/Floor or Floor/Wall.
a.
A01 (floor/floor) as manufatured by Inpro.
b.
A02 (floor/wall) as manufatured by Inpro.
c.
Product: JointMaster-430-A01 or A02, dual tapered plate and sloped frame
(height 1-1/2 inches (38mm)) vertical change-in-plane not to exceed 3/16 inch
(4.76 mm) (or 10% slope) at any point, suitable for all finishes, hidden fastener.
d.
Product: JointMaster-432-A01 or A02, dual tapered plate and sloped frame
(height 1-1/2 inches (38mm)) vertical change-in-plane not to exceed 3/16 inch
(4.76 mm) (or 10% slope), suitable for all finishes, exposed fastener.
e.
Product: JointMaster-441-A01 or A02, frame height 1 inch (25mm), beveled
plate suitable for all finishes, exposed fastener.
f.
Product: JointMaster-421-A01 or A02, aluminum frame and wing height 1-5/8
inches (41.3mm) or 1-7/8 inches (47.6mm), beveled aluminum plate suitable for
all floor finishes, exposed fastener.
g.
Product: JointMaster-423-A01 or A02, aluminum frame and wing height 1-5/8
inches (41.3mm) or 1-7/8 inches (47.6mm), stainless steel beveled plate
suitable for all floor finishes, exposed fastener.
h.
Product: JointMaster-425-A01 or A02, aluminum frame and stainless steel wing
height 1-5/8 inches (41.3mm) or 1-7/8 inches (47.6mm), stainless steel beveled
plate suitable for all floor finishes, exposed fastener.
i.
Product: JointMaster-426-A01 or A02, frame and wing height 1-5/8 inches
(41.3mm) or 1-7/8 inches (47.6mm), beveled plate suitable for all floor finishes,
exposed fastener.
1)
Plate Materials: Aluminum.
2)
Plate Materials: Stainless steel.
j.
Product: JointMaster-427-A01 or A02, frame and wing height 1-5/8 inches
(41.3mm) or 1 7/8 inches (47.6mm), beveled plate accepts 1/8 inch (3 mm)
floor finishes, fastener hidden under floor finish.
k.
Product: JointMaster-428-A01 or A02, frame and wing height 1-5/8 inches
07 95 13-14
3.
4.
5.
(41.3mm) or 1-7/8 inches (47.6mm), beveled plate accepts 3/8 inch (9.5 mm)
floor finishes, fastener hidden under floor finish.
l.
Joint Width: 2 inches (50 mm).
m.
Joint Width: 3 inches (75 mm).
n.
Joint Width: 4 inches (100 mm).
o.
Joint Width: 6 inches (150 mm).
p.
Joint Width: 8 inches (200 mm).
Application: Floor Systems - Surface Mount, Floor/Floor or Floor/Wall.
a.
A01 (floor/floor) as manufatured by Inpro.
b.
A02 (floor/wall) as manufatured by Inpro.
c.
Product: JointMaster-471-A01 or A02, tapered frame accepts 1/8 inch (3 mm)
floor finish but suitable for any floor finish, double tapered plate with hidden
fastener.
1)
A01: Surface mounted aluminum frame with continuous tapered
aluminum center plate held in place by steel centering bar with
compression spring assembly.
2)
A02: Surface mounted aluminum floor and wall frame with continuous
tapered aluminum half plate;
d.
Product: JointMaster-472-A01 or A02, tapered frame accepts 1/8 inch (3 mm)
floor finish but suitable for any floor finish, double tapered plate with exposed
fastener.
e.
Product: JointMaster-401-A01 or A02, frame suitable for all finishes, beveled
plate, exposed fastener.
1)
Plate Materials: Aluminum.
2)
Plate Materials: Stainless steel.
f.
Frame Type: Flat.
1)
Product: JointMaster-471-A01 (floor/floor) as manufatured by Inpro.
g.
Frame Type: Corner.
1)
Product: JointMaster-471-A02 (floor/wall) as manufatured by Inpro.
2)
Surface mounted aluminum floor and wall frame with continuous tapered
aluminum half plate;
h.
Joint Width: 2 inches (50 mm).
i.
Joint Width: 3 inches (75 mm).
j.
Joint Width: 4 inches (100 mm).
k.
Joint Width: 6 inches (150 mm).
l.
Joint Width: 8 inches (200 mm).
Application: Floor Systems - New to Existing (Renovation), Floor/Floor.
a.
Product: JointMaster-461-A01, surface mounted tapered frame accepts 1/8
inch floor finish and recessed frame (height 1-1/2 inches (38mm)) with double
tapered plate, hidden fastener.
1)
Combination recessed and surface mounted aluminum frame with
continuous tapered aluminum center plate held in place by steel
centering bar with compression spring assembly.
b.
Joint Width: __ inches (__ mm).
c.
Joint Width: As inidcated or required.
Application: Wall/ceiling.
a.
Frame Type: Flat.
1)
Product: JointMaster-481-A07 (wall/wall and ceiling/ceiling) as
manufatured by Inpro.
2)
Semi-recessed continuous aluminum drywall frame with elevated
aluminum plate.
b.
Frame Type: Flat.
1)
Product: JointMaster-491-A07 (wall/wall and ceiling/ceiling) as
manufatured by Inpro.
2)
Surface mounted continuous aluminum frame with elevated aluminum
plate.
07 95 13-15
c.
6.
7.
8.
9.
10.
11.
12.
13.
F.
Frame Type: Corner.
1)
Product: JointMaster-481-A09 (wall/corner and wall/ceiling) as
manufatured by Inpro.
2)
Semi-recessed continuous aluminum drywall frame with elevated bent
aluminum plate.
d.
Frame Type: Corner.
1)
Product: JointMaster-491-A09 (wall/corner and wall/ceiling) as
manufatured by Inpro.
2)
Surface mounted continuous aluminum frame with elevated bent
aluminum plate.
e.
Joint Width: 2 inches (50 mm).
f.
Joint Width: 3 inches (75 mm).
g.
Joint Width: 4 inches (100 mm).
h.
Joint Width: 6 inches (150 mm).
i.
Joint Width: 8 inches (200 mm).
j.
Joint Width: 12 inches (300 mm).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Seismic Floor Joint Cover Assemblies: "Pop-Up" type; JointMaster 500 Series.
1.
Design: Recessed aluminum frame with tapered central pan held in place by steel
centering bar and compression spring assembly, designed to pop up under seismic
movement.
a.
Blockout required on one side only for both floor to floor and floor to wall
conditions
b.
Centering Bars (where required) shall be fabricated from zinc plated steel.
c.
Spring pack (where required) by manufacturer.
d.
Wire pack (where required) by manufacturer. High tensile 1/8 inch (3 mm)
Marine Grade Stainless Steel.
e.
Allowable load on floor joint cover plate shall be 500 lb (227 kg) for standard
loads, 1000 lb (454 kg) for moderate loads, and 2000 lb (907 kg) for heavy duty
loads.
2.
Product: JointMaster-501-A01 (floor/floor) as manufatured by Inpro. Frame height 2
inches (51 mm), recessed pan of 1-1/2 inches (38 mm) suitable for all floor finishes,
sightline not to exceed 1 inch (25 mm), spring reset.
3.
Product: JointMaster-501-A02 (floor/wall) as manufatured by Inpro. Frame height 2
inches (51mm), recessed pan of 1-1/2 inches (38 mm) suitable for all floor finishes,
sightline not to exceed 2-1/4 inches (57 mm), hinge reset.
4.
Product: JointMaster-502-A01 (floor/floor), frame height 2 inches (51 mm), recessed
pan of 1-1/2 inches (38 mm) suitable for all floor finishes, sightline not to exceed 2-1/4
inches (57.15 mm), hinge reset. Blockout required on one side for both floor to floor
and floor to wall conditions.
5.
Product: JointMaster-502-A02 (floor/wall), frame height 2 inches (51 mm), recessed
07 95 13-16
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
G.
pan of 1-1/2 inches (38 mm) suitable for all floor finishes, sightline not to exceed 2-1/4
inches (57.15 mm), hinge reset. Blockout required on one side for floor to wall
conditions.
Joint Width: 2 inches (50 mm).
Joint Width: 3 inches (75 mm).
Joint Width: 4 inches (100 mm).
Joint Width: 6 inches (150 mm).
Joint Width: 8 inches (200 mm).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Seismic Floor Joint Cover Assemblies: Heavy Duty Glide Plate JointMaster 700 Series;
recessed heavy duty aluminum frame.
1.
Allowable load on floor joint cover plate shall be 500 lb (227 kg) for standard loads,
1000 lb (454 kg) for moderate loads, and 2000 lb (907 kg) for heavy duty loads.
2.
System Type: Heavy duty center bar system, continuous aluminum plate with steel
centering bar mechanism.
a.
Product: JointMaster-721-A01 (floor/floor) as manufatured by Inpro. Frame and
wing height 1-5/8 inches (41mm) with aluminum beveled plate.
b.
Product: JointMaster-721-A02 (floor/wall) as manufatured by Inpro. Frame and
wing height 1-5/8 inches (41mm) with aluminum beveled plate.
c.
Product: JointMaster-723-A01 or A02 as manufatured by Inpro. Frame and
wing height 1-5/8 inches (41 mm) with stainless steel beveled plate.
d.
Product: JointMaster-725-A01 or A02 as manufatured by Inpro. Frame and
stainless steel wing height 1-5/8 inches (41 mm) with stainless steel beveled
plate.
e.
Joint Width: 2 inches (50 mm).
f.
Joint Width: 4 inches (100 mm).
g.
Joint Width: 6 inches (150 mm).
h.
Joint Width: 8 inches (200 mm).
i.
Joint Width: 12 inches (306 mm).
3.
Recessed Mount Heavy Duty Center Bar System:
a.
Product: JointMaster 741-A01 (floor/floor) as manufatured by Inpro. Frame
height 1 inch (25 mm) flush mount with cover plate surface mount.
b.
Product: JointMaster 741-A02 (floor/wall) as manufatured by Inpro. Frame
height 1 inch (25 mm) flush mount with cover plate surface mount.
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 4 inches (101 mm).
e.
Joint Width: 6 inches (152 mm).
4.
Surface Mount Heavy Duty Center Bar System:
a.
Product: JointMaster 757-A01 (floor/floor) as manufatured by Inpro. Dual
tapered plate and sloped frame (height 2 inches (51 mm) Vertical change-inplane not to exceed 1/4 inch (6 mm) (or 8% slope) at any point.
07 95 13-17
b.
5.
6.
7.
8.
9.
10.
11.
12.
2.5
Product: JointMaster 757-A02 (floor/wall) as manufatured by Inpro. Dual
tapered plate and sloped frame (height 2 inches (51 mm) Vertical change-inplane not to exceed 1/4 inch (6 mm) (or 8% slope) at any point.
c.
Product: JointMaster 767-A01 (floor/floor) as manufatured by Inpro. Dual
tapered plate and sloped frame (height 2 inches (51 mm) Vertical change-inplane not to exceed 1/4 inch (6 mm) (or 8% slope) at any point with additional
frame anchoring.
d.
Product: JointMaster 787-A01 or A02 as manufatured by Inpro. Serrated plate
with a dual tapered profile. Vertical change in plane not to exceed 1/4 inch (6
mm) (or 8% slope) at any point. Tapered frame with a depth not to exceed 1
inch (25mm). System includes vehicular grade center bar and sound
dampener/water barrier seal.
e.
Joint Width: 4 inches (101 mm).
f.
Joint Width: 6 inches (152 mm).
g.
Joint Width: 8 inches (203 mm).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
EXTERIOR SYSTEMS
A.
Seismic Joint Cover Assemblies: JointMaster 600 Series.
1.
Elastomeric Seal: Dual durometer santoprene with 60 Shore A and 90 Shore A or
pleated santoprene seal with durometer of 70 shore A including a UV inhibitor. No
neoprene substitutions allowed to reduce negative environmental impacts. Colors
shall be selected from manufacturer's standard range.
2.
Design: Dual durometer flat seal shall maintain inherent dimensional stability and
include structural spine inserts (where applicable) allowing for additional load
resistance. Bellows depth not to exceed 5/8 inch (16 mm). Wall thickness not less
than 1/8 inch (3 mm). Centering bars (where required) shall be fabricated from zinc
coated steel.
3.
Application: Exterior Wall Systems - Recessed/Flush Mount, Wall/Wall (and
Ceiling/Ceiling) or Wall/Corner (and Ceiling/Wall).
a.
Elastomeric seal, continuous Santoprene seal and continuous integral backseal
retained by continuous aluminum frame at each side of joint.
b.
Product: JointMaster-615-A07 (wall/wall and ceiling/ceiling) as manufatured by
Inpro. Pleated seal system with back seal suitable for all wall finishes.
c.
Product: JointMaster-615-A09 (wall/corner and wall/ceiling) as manufatured by
Inpro. Pleated seal system with back seal suitable for all wall finishes.
d.
Joint Width: 2 inches (50 mm).
e.
Joint Width: 3 inches (75 mm).
f.
Joint Width: 4 inches (100 mm).
g.
Joint Width: 5 inches (125 mm).
h.
Joint Width: 6 inches (150 mm).
07 95 13-18
4.
5.
6.
i.
Joint Width: 8 inches (200 mm).
Application: Exterior Wall Systems - Recessed/Flush Mount, Wall/Wall (and
Ceiling/Ceiling) or Wall/Corner (and Ceiling/Wall).
a.
Walls and ceilings, 12 Inch (305 mm) wide, continuous Santoprene seal
retained by continuous aluminum frame at each side of joint and continuous
center frame assembly mounted on expandable pantograph assembly.
b.
Product: JointMaster-616-A07 (wall/wall and ceiling/ceiling) as manufatured by
Inpro. Pleated seal with intermediate frame and center bar system with back
seal suitable for all wall finishes.
c.
Product: JointMaster-616-A09 (wall/corner and wall/ceiling) as manufatured by
Inpro. Pleated seal with intermediate frame and center bar system with back
seal suitable for all wall finishes.
d.
Joint Width: 8 inches (200 mm).
e.
Joint Width: 10 inches (250 mm).
f.
Joint Width: 12 inches (300 mm).
g.
Joint Width: 18 inches (450 mm).
h.
Joint Width: 24 inches (600 mm).
Application: Walls, surface mounted center bar system, continuous surface mounted
aluminum frame with elevated continuous aluminum plate retained by centering bar
mechanism;
a.
Product: JointMaster-651-A07 (wall/wall) as manufatured by Inpro. Cover plate
system with back seal suitable for all finishes.
b.
Product: JointMaster-651-A09 (wall/corner) as manufatured by Inpro.
c.
Product: JointMaster-620-A07 or A09 as manufatured by Inpro. Pleated seal
system with back seal suitable for all finishes.
d.
Product: JointMaster-621-A07 or A09 as manufatured by Inpro. Pleated seal
system with intermediate frame and center bar with back seal suitable for all
finishes.
e.
Joint Width: 1 inch (25 mm).
f.
Joint Width: 2 inches (50 mm).
g.
Joint Width: 4 inches (100 mm).
h.
Joint Width: 5 inches (125 mm).
i.
Joint Width: 6 inches (150 mm).
j.
Joint Width: 8 inches (200 mm).
k.
Joint Width: 12 inches (300 mm).
Application: Roof joints, continuous surface mounted aluminum frame with elevated
continuous aluminum plate retained by centering bar mechanism.
a.
Product: JointMaster-661-A01 (roof/roof) as manufatured by Inpro. Bent metal
frame plate system, suitable for 45 degree angled curb conditions, back seal
standard.
b.
Product: JointMaster-661-A02 (roof/wall) as manufatured by Inpro. Bent metal
frame plate system, suitable for 45 degree angled curb conditions, back seal
standard.
c.
Product: JointMaster-691-A01 (roof/roof) as manufatured by Inpro. Bent metal
frame plate system, suitable for 90 degree angled curb conditions, back seal
standard.
d.
Product: JointMaster-691-A02 (roof/wall) as manufatured by Inpro. Bent metal
frame plate system, suitable for 90 degree angled curb conditions, back seal
standard.
e.
Product: JointMaster-651-A01 (roof/roof) as manufatured by Inpro. Metal frame
plate system, suitable for all flat curb conditions, back seal standard.
f.
Product: JointMaster-651-A02 (roof/wall) as manufatured by Inpro. Metal frame
plate system, suitable for all flat curb conditions, back seal standard.
g.
Vapor Barrier: Continuous EPDM sheet.
h.
Joint Width: 1 inch (25 mm).
i.
Joint Width: 2 inches (50 mm).
07 95 13-19
7.
8.
9.
j.
Joint Width: 4 inches (100 mm).
k.
Joint Width: 6 inches (150 mm).
l.
Joint Width: 8 inches (200 mm).
m.
Joint Width: 12 inches (300 mm).
Applictation: Roof joints, elastomeric bellows.
a.
Roof Cants: 4 inches (102 mm) metal flanges bellow system for setting in
mastic. Suitable for canted curb conditions. System can be surface mounted
without cants.
1)
Product: JointMaster-672-A01 (cant/cant) as manufatured by Inpro.
2)
Product: JointMaster-672-A02 (cant/wall) as manufatured by Inpro.
b.
Roof Curbs: 4 inches (102 mm) preformed bent metal curb flanges for setting in
mastic. Suitable for various curb conditions.
1)
Product: JointMaster-674-A01 (curb/curb) as manufatured by Inpro.
2)
Product: JointMaster-674-A02 (curb/wall) as manufatured by Inpro.
c.
Joint Width: 2 inches (50 mm).
d.
Joint Width: 3 inches (75 mm).
e.
Joint Width: 4 inches (100 mm).
f.
Joint Width: 6 inches (150 mm).
g.
Joint Width: 8 inches (200 mm).
h.
Roof Bellows: Black EPDM bellows with closed cell foam backer and
galvanized flanges.
i.
Roof Bellows: Custom White EPDM bellows with closed cell foam backer and
galvanized flanges.
j.
Aluminum Flanges.
k.
Stainless Steel Flanges.
l.
Copper Flanges.
m.
EPDM Flanges.
n.
Provide factory preformed intersections and transitions for bellows and flanges
as shown on drawings.
Application: Exterior Wall/wall.
a.
Design: Minimal sightline pan system suitable for all wall finishes. Depth of pan
shall accommodate varying finishes from 1/2 inch (13 mm) to 2 inches (51 mm).
b.
Product: JointMaster 601-A07-300 (wall/wall) as manufatured by Inpro.
c.
Product: JointMaster 601-A07-600 (wall/wall) as manufatured by Inpro.
d.
Product: JointMaster 601-A07-450 (wall/wall) as manufatured by Inpro.
e.
Product: JointMaster 601H-A07-300 (wall/wall) as manufatured by Inpro.
f.
Product: JointMaster 601H-A07-450 (wall/wall) as manufatured by Inpro.
g.
Product: JointMaster 601H-A07-600 (wall/wall) as manufatured by Inpro.
h.
Compliance: Signed and sealed structural calculations by a Licensed Engineer
as provided by manufacturer.
i.
Design:
1)
Hinged cover plate or pan to be infilled with adjacent architectural
systems to disguise expansion joint; compatible with materials including
but not limited to glazing, metal panels and masonry units.
2)
Compression springs correctly reposition pan to nominal position after
system movment.
3)
Sightlines: 1-3/16 inches (27 mm) and 3-1/16 inches (78 mm).
4)
Height: 1-1/2 inches (38 mm).
Application: Wall/corner.
a.
Design: Minimal sightline pan system suitable for all wall finishes. Depth of pan
shall accommodate varying finishes from 1/2 inch (13 mm) to 2 inches (51 mm).
b.
Product: JointMaster 601-A09-300 (wall/corner) as manufatured by Inpro.
c.
Product: JointMaster 601-A09-600 (wall/corner) as manufatured by Inpro.
d.
Product: JointMaster 601-A09-450 (wall/corner) as manufatured by Inpro.
e.
Product: JointMaster 601H-A09-300 (wall/corner) as manufatured by Inpro.
f.
Product: JointMaster 601H-A09-450 (wall/corner) as manufatured by Inpro.
07 95 13-20
g.
h.
10.
11.
12.
13.
14.
15.
16.
17.
18.
2.6
Product: JointMaster 601H-A09-600 (wall/corner) as manufatured by Inpro.
Compliance: Signed and sealed structural calculations by a Licensed Engineer
as provided by manufacturer.
i.
Design:
1)
Hinged cover plate or pan to be infilled with adjacent architectural
systems to disguise expansion joint; compatible with materials including
but not limited to glazing, metal panels and masonry units.
2)
Compression springs correctly reposition pan to nominal position after
system movment.
3)
Sightlines: 1-3/16 inches (27 mm) and 3-1/16 inches (78 mm).
4)
Height: 1-1/2 inches (38 mm).
Finishes:
a.
Aluminum: Standard Mill finish for 611/612, 615/616, 651, 620/621 and 601.
b.
Aluminum: Color Anodized.
c.
Aluminum: Kynar Painted.
d.
Aluminum: Custom Color Painted.
e.
Stainless Steel: 2B (optional for 651 cover plate).
Integral Vinyl Vapor Barrier. 45 mils thick fabric reinforced EPDM or extruded integral
PVC.
Insulated Vapor Barrier: Owens Corning EcoTouch Batt insulation sandwiched by an
adhered and pinned 45 mil fabric reinforced EPDM meeting ASTM E 1399
requirements.
Drainage Fittings for horizontal and vertical applications (as required).
Fire Barrier: 925 Mineral Wool and Sealant Fire Barrier System to UL2079.
Fire Barrier: 935 Textiled Wool and Sealant Fire Barrier System to UL2079 required
for indicated fire resistance rating.
Fire Barrier: 950 Blanket Fire Barrier System to UL2079 with hose stream test to walls
required for indicated fire resistance rating.
Fire Barrier: F520 Blanket System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
Fire Barrier: 990/995 Foam System to UL2079 with hose stream test to walls required
for indicated fire resistance rating.
COMPRESSION SEALS
A.
Compression Seals: 1000 Series as manufactured by Inpro.
B.
Materials:
1.
Santoprene or Thermoplastic Elastomer (TPE) (AR/CR Series only): 65 shore A
hardness.
2.
Lubricant Adhesive (BR/DR Series only): Single component, moisture curing
polyurethane lubricant.
3.
Epoxy (AR Series): High strength two-part 100% solid, moisture insensitive epoxy.
4.
Elastomeric Concrete Header (CR Series only): Two-component 100% solid, modified
polyurethane elastomeric header.
5.
Elastomeric Tack Coat (CR Series only): Two-component, low-viscosity modified
elastomeric priming agent.
6.
Neoprene (BR/DR Series only): Delastic neoprene with 55 shore A hardness.
C.
Compression Seals for Interior and Exterior Floors:
1.
JointMaster 1000 Series Compression Seals - Santoprene Seal (TPE):
a.
Visible face holds linear lines during expansion and compression.
b.
Webbing profile to provide a uniform horizontal and vertical load resistance.
c.
Material is heat weld-able allowing for watertight seams and transitions.
d.
Highly resistant to UV degradation, extreme temperatures, and chemicals.
2.
JointMaster 1000 Series Compression Seals - Neoprene Seal:
07 95 13-21
3.
D.
2.7
a.
Highly resistant to virtually all abrasive chemicals and liquids.
JointMaster 1000 Series Compression Seals - System Profiles:
a.
Floor Systems - Flush Mount, Floor/Floor and Floor/Wall
1)
AR, suitable for heavy pedestrian and moderate vehicle loadings and
installed with two-part epoxy. Incorporation of sidewall ribs to pool epoxy
and add surface area for increased adhesion to deck.
2)
CR, suitable for heavy duty and vehicular loadings, installed with tack
coat and elastomeric header. Dual barbed wings and header keyway
required for secure placement of system.
3)
BR, suitable for heavy duty and vehicular loadings at smaller joint widths,
installed with two-component epoxy or single component lubricant
adhesive.
4)
DR, suitable for heavy duty and vehicular loadings at smaller joint widths.
UV, temperature, and chemical resistant, installed with two-component
epoxy or single component lubricant adhesive.
Fabrication:
1.
Field assemble seals provided in longest length available with adhesives and
accessories.
2.
Fabricate special transitions and corner fittings as required. Miter and weld
elastomeric seal as applicable.
FIRE BARRIER SYSTEMS
A.
Fire Barrier Systems: 900 Series as manufatured by Inpro.
B.
Materials:
1.
Mineral Wool (925): Preformed, semi rigid, non-combustible mineral/rock wool.
2.
Insulated Wool (935): Non-combustible, semi rigid, textile fiberglass with fiberglass
matt facing.
3.
Silicone Sealant: Non-slumping single component smoke resistant silicone sealant.
4.
Insulation: Ceramic blanket (950) or intumescent ceramic blanket (900).
5.
Foam (990/995): Open cell polyurethane.
6.
Galvanized Steel: 20 gauge (900) or 24 gauge (950) and 22 gauge (chase cover
only).
7.
Stainless Steel Foil (where applicable): 304 0.2 mils.
8.
Shear Screen (optional, 900 and 950): Stainless steel mesh.
C.
Fire Barrier Systems For Horizontal And Vertical Applications
1.
JointMaster 925 Series - Mineral Wool and Sealant:
a.
Mineral Wool: Preformed, semi rigid, non-combustible mineral/rock wool.
b.
Water based fire caulk for horizontal and vertical conditions.
2.
JointMaster 935 Series - Textiled Wool and Sealant:
a.
Non-combustible, semi rigid, textile fiberglass with fiberglass matt facing.
b.
Silicone based fire caulk for horizontal and vertical conditions.
3.
JointMaster 950 Series - Fire Blanket:
a.
Ceramic blanket insulation encapsulated with stainless steel foil and stainless
steel shear screen optional.
b.
24 gauge flanges are pre-attached for joint widths eight inches and up, offered
in surface mounted or concealed profile as required.
c.
No caulk required.
4.
JointMaster 990/995 Series - Fire Rated Foam:
a.
990 2 Hr. Fire Rated Foam Seal - 25% Movement:
1)
Foam joint impregnated with a fire-retardant agent and a UV resistant
compound.
2)
System rating is not compromised due to vandalism or damage to the
face seal.
07 95 13-22
3)
5.
D.
2.8
System composed of a monolithically poured body to eliminate
delamination of elements.
4)
Exposed surface can be uncoated, single side coated to enhance
waterproofing, and double side coated with pick resistant sealant
available on one side.
b.
990 3 Hr. Fire Rated Foam Seal - 25% Movement:
1)
Foam joint impregnated with a fire-retardant agent and a UV resistant
compound.
2)
System rating is not compromised due to vandalism or damage to the
face seal.
3)
System composed of a monolithically poured body to eliminate
delamination of elements.
4)
Exposed surface can be uncoated, single side coated to enhance
waterproofing, and double side coated with pick resistant sealant
available on one side.
c.
995 2 Hr. Fire Rated Foam Seal - 50% Movement:
1)
Foam joint impregnated with a fire-retardant agent and a UV resistant
compound.
2)
System rating is not compromised due to vandalism or damage to the
face seal.
3)
System composed of a monolithically poured body to eliminate
delamination of elements.
4)
Exposed surface can be uncoated, single side coated to enhance
waterproofing, and double side coated with pick resistant sealant
available on one side.
d.
995 3 Hr. Fire Rated Foam Seal - 50% Movement:
1)
Foam joint impregnated with a fire-retardant agent and a UV resistant
compound.
2)
System rating is not compromised due to vandalism or damage to the
face seal.
3)
System composed of a monolithically poured body to eliminate
delamination of elements.
4)
Exposed surface can be uncoated, single side coated to enhance
waterproofing, and double side coated with pick resistant sealant
available on one side.
JointMaster 900/950 Series - System Accessories:
a.
Chase Covers.
Fabrication:
1.
Mineral Wool & Sealant Fire Barrier Systems - None required.
2.
Fire Blanket Systems:
a.
Fire Blanket System may be field-cut, spliced and transitioned according to
manufacturer recommendations.
b.
Galvanized Mounting Flanges may be field-cut and spliced according to
manufacturer instructions.
3.
990/995 Fire Rated Foam Seal Systems may be field-cut, spliced and transitioned
according to manufacturer recommendations.
FIRE BLANKET SYSTEMS
A.
Fireline 520 Series as manufatured by Inpro.
B.
Materials:
1.
Ceramic Cloth: Treated insulated glass textile.
2.
Aluminum Foil: Jacketed aluminum foil, 1 mil thick.
3.
Ceramic Fiber: Ceramic blanket with density no less than 8 pcf.
07 95 13-23
4.
5.
6.
7.
8.
9.
Expanded Metal Flanges: 18 gauge galvanized steel.
Solid Metal Flanges: 20 gauge galvanized steel.
Silicone Membrane: Silicone coated fiberglass fabric, 18 mils thick (Waterguard only).
Silicone Caulk: Clear silicone (Waterguard only).
Galvanized Steel: 22 gauge (chase cover only).
Stainless Steel Foil (where applicable): 304 0.2 mils.
C.
Fire Barrier Systems For Horizontal And Vertical Applications:
1.
Fireline 520 Series - Standard Fire Blanket:
a.
Factory pre-assembled splices required.
b.
1, 2, and 3 hour blanket where required.
c.
Surface mount, inside mount and bottom mount flanges available as project
conditions dictate.
d.
No fire caulk required.
2.
Fireline 520 Series - Waterguard Fire Blanket:
a.
Factory pre-assembled splices required.
b.
Water resistant.
c.
Surface mount, inside mount and bottom mount flanges available as project
conditions dictate.
d.
Silicone caulk required at splices.
3.
Fireline 520 Series - Fire Blanket System Accessories:
a.
Chase Covers.
b.
Drainage fittings (optional for Waterguard only).
D.
Fabrication:
1.
Fire Blanket Systems:
a.
Fire Blanket System may be field-cut and transitioned according to
manufacturer recommendations.
b.
Fire Blanket System may be installed utilizing male/female splice and factory
transitions.
PART 3 EXECUTION
3.1
EXAMINATION
A.
3.2
PREPARATION
A.
3.3
Verify that substrates are in proper condition to receive installation of expansion joint covers.
1.
Confirm that blockout dimensions are appropriate for recessed systems.
2.
Confirm that selected expansion joint covers are appropriate for actual joint
dimensions.
Clean substrate before installation to remove dust, debris, and loose particles.
INSTALLATION
A.
General: Install expansion joint covers in strict accordance with manufacturer's instructions.
Align work level and flush with adjacent surfaces, and rigidly anchor to substrate. Make
allowances for structural gap that varies at time of installation from nominal design gap.
B.
Metal Frames: Perform cutting and fitting required to install the joint system. All frames must
be set on, and in continuous contact with solid substrate. Anchor at internvals as required by
Manufactureris systems.
C.
Fire Rated Assemblies: Where expansion joint covers are required in fire rated construction,
install fire rated systems to comply with manufacturer's requirements and in strict
conformance with tested assemblies.
07 95 13-24
D.
3.4
3.5
Vapor Barriers: Where required, install in strict accordance with manufacturer's instructions
to assure continuous protection. Install drainage fittings where required by project
circumstances.
INSPECTION
A.
Prior to payment by the general contractor, a designated inspector will select a random 10
percent of the joint systems and have the assembly covers removed for inspection. The
purpose of this will be to inspect the concrete substrates, filler materials, anchorage of the
joint assembly and fire barrier systems that are hidden from view.
B.
Corrective action will be designated as required. Should a majority of the 10 percent scope
be deemed as unacceptable, the Inspector will require that additional lengths be opened for
inspection. This process will continue until the Inspector and general contractor are satisfied
and the Manufactureris warranties are secured.
ADJUSTING AND CLEANING
A.
Verify that expansion joint covers are plumb and level and are rigidly secured to substrate;
make any adjustments required.
B.
Clean expansion joint covers and immediate areas of installation, using materials and
methods recommended by manufacturer. Remove from project site packaging and debris
caused by installation.
END OF SECTION
07 95 13-25