LP Series U Uninterruptible Power Supply Technical Specification & Features LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE Key Features & Benefits • True On-Line Double Conversion … provides highest level of power reliability • Fully isolated output … additional power fault protection • Power factor corrected input (>0.99) … clean input • Scalable Using GEDE’s Unique “Redundant Parallel Architecture (RPA) … maximum reliability • Superior battery management … enhanced battery life time • ECO-mode … energy savings for less critical loads e.g., during off hours, emergency lights etc • Small Footprint … easy to place Key Features & Benefits (continued) • Excellent inrush current handling… prevents tripping protection devices • Superior overload handling … protection against unplanned overloads • Minimal Output Voltage Distortion of <3% … stable power for the load • Multi-functional LCD screen … easy to operate • Multi language display … Spanish etc • Automatic battery testing – every 500 hrs. … no “surprises” • Cold start … unit can be started with no AC present • No load shutdown … prevents unnecessary discharging of batteries Key Features & Benefits (continued) • Backfeed relay … maximum safety • EPO- Emergency Power Off… maximum safety • Multiple I/O voltages … 120,240, 208 VAC • Alarm interface : RS 232 and OC contacts … easy to integrate with existing systems • Redundant power supply for critical functions (LCD, Bypass) … increased reliability • UL, C-UL and CE markings for worldwide applications ...fits to many different mains Product Specifications LP Series 5-11U LP Series 6-11U 5 kVA- 4 kW 6 kVA - 4.8 kW LP Series 8-11U 8 kVA - 6.4 kW LP Series 10-11U 10 kVA - 8 kW Voltages and Frequencies Input Voltage • 208 – 230/240 • 120 V option (for 5/6 kVA only in additional transformer cabinet; Input Frequency • 45-65 Hz Output Voltage • 120 + 208 + 230/240 • Fully isolated, even in bypass mode Output Frequency • 50 or 60 Hz • (Front Panel Selectable) Flexible input and output voltages and frequency Operating Mode True On-Line - double conversion • Bypass enable / disable … in frequency conversion mode no alarms … in case of weak mains protects the equipment against operations on mains • Programmable frequency tracking range (2%, 4%, 6%) … compatible with gen-sets with wider frequency range • HF PWM technique … compact design , low-losses, excellent characteristics Output Completely Independent of Input Voltage and Frequency LP Series U Front Panel • LCD screen 2 lines with 16 characters - Information Screen status and alarm messages - Service screen internal settings test screens - Set Up Screen setting of parameters • Push buttons (keypads to scroll up, down, reset and enter) • LED operation / alarm status • On/Off switch turns unit on/off completely, including bypass on back of unit Rear Panel On/Off switch turns unit on/off completely, including bypass Manual Bypass Battery fuses Utility & Bypass Protection Magnetic Circuit breakers for overload or short circuit in the UPS load I/O terminals RS232/contact interface/EPO Conduit box Optional: SNMP or relay card EMI Cable entry Optional: RPA card DC Connector for external batteries Technology without compromise EMI protection No inrush current during start up on bypass Bypass MCB Isolation on BYPASS MANUAL bypass Elektronic Bypass Backfeed protection I/O terminals Surge protection RFI Filter Mains MCB External Battery Batteries N RFI Filter Stepdown Converter L •120/240 •208 H bridge Output Converter HF input converter Internal Supply LCD Isolation transformer always active 4X up Battery charging capacity optional up120toVolt60 minutes run time auto-input xfrmr L MICRO- processor CONTROL L without additional charger enter operation alarm down General alarm, Utility failure Bypass active, Batterey low UPS Shutdown RS232 Emergency shutdown INTERFACE Option: SNMP card External battery disconnected •GND •208 •120/240 Technology with Premium Performance Input voltage:187-285 V at 100% load Bypass MCB RFI Input voltage: 150-285 V at 50 % load internal supply F3 P Line MCB N THD-I < 10% PF 1 input converter Technology : Output Converter Inverter DC voltage +380V Bypass 240 V 208V Isolation on bypass Output HS C1 H-BRIDGE Output converter Heatsink temp.sensor •EMI F3 C2 current 4X IGBT Output transformer temp.sensor Fan speed controlled by load & heat sink temperature 2x 120 V 1x 120 V 208 V 240 V Battery Specifications • Standard 20 X batteries 12V/7Ah (5/6kVA) or 12V/12Ah (8/10kVA) • Charge voltage = 271V, 13.55V/battery • Constant current/constant voltage characteristic + boost charge current is ± 0.3 C • Temperature protected till 45ºC • Battery extension up to 500 Ah • Battery capacity programmable over LCD/serial port Superior Battery Management • Ripple-free Boost Charging • Temperature Compensated • • • • • • Charging Load dependent end of discharge voltage No-load Shutdown Automatic Battery Test /every 500 hours Deep Calibration Test Load dependent runtime prediction Load dependent battery low signal • Maximum Up-time • Prevents Damage • Prolonged Battery Lifetime • No Surprises Output Performance • Output THD < 3% for linear loads • Output Power Factor = 0.8 • Output filter performance control enabling robust operation • Fully isolated output • Protected against: – – – – – Low/high DC voltage Over-temperature Overload AC on Output Short circuit No Compromise on Output Performance Bypass Specifications Bypass MCB Bypass thyristors Hall Sensor Output current L1 Manual Bypass Switch • to outputtransformer Line MCB UPS L2 • • • • • • Bypass input voltage -10 to +10% Bypass frequency window selectable 2%, 4%, 6% Tracking rate 1 Hz/sec “low”, 5 Hz/sec “high” Protected against overload Short circuit protection State-of-the-art Bypass Galvanic isolation Communication • Standard: RS 232 dialogue UPS shutdown Emergency Power off ( EPO ) External DC - fuse alarm • Optional: SNMP - card RS 232 is not available if SNMP is installed Dry contacts Easy to integrate into computer network Available Options • Power Distribution unit (PDU) • External battery cabinets • External battery cable • Seismic anchor • SNMP interface card • Relay interface card • RPA kit (Redundant Parallel Architecture) • Alarm boxes • Connectivity products, like Splitter box; interface kits; interface software for all common OS, incl Java • 120 Volt input voltage transformer/cabinet