MINI-LINK TN ETSI Technical - HTC

advertisement

MINI-LINK TN ETSI

Technical

4/22109-FGC 101 190/1 Uen Rev.B

1

Transmission & Transport Networks

Our product offering

MINI-LINK Management

MINI-LINK BAS

Partner products

4/22109-FGC 101 190/1 Uen Rev.B

2

MINI-LINK TN

MINI-LINK HC

MINI-LINK E

Transmission & Transport Networks

MINI-LINK TN

Applications

1st mile broadband access

Mobile networks

4/22109-FGC 101 190/1 Uen Rev.B

3

2nd mile broadband access

Transmission & Transport Networks

MINI-LINK TN

• Functionality Overview

– Microwave radio function

– Traffic routing function

– Circuit Management

– STM-1 Terminal Multiplexer function

– Ethernet function

– Protection mechanisms

– Synchronization

– Co-siting function

– Operation & Maintenance

– Data Communication Network

– Management Tools

• Product Overview

4/22109-FGC 101 190/1 Uen Rev.B

4

Transmission & Transport Networks

MINI-LINK TN

Microwave radio function

C-QPSK

16 QAM

7 GHz

8 GHz

13 GHz

15 GHz

18 GHz

23 GHz

26 GHz

28 GHz

32 GHz

38 GHz

128 QAM*

4/22109-FGC 101 190/1 Uen Rev.B

2-16xE1

4-32xE1

5

64xE1*

* In combination with MINI-LINK HC indoor unit

Transmission & Transport Networks

MINI-LINK TN

Microwave radio function

Capacity and modulation agile radios

One radio - 4 to 155 Mbit/s

One radio - 4 to 128 QAM

 Easy upgrades & logistics

4/22109-FGC 101 190/1 Uen Rev.B

2-16xE1 64xE1*

4-32xE1

* In combination with MINI-LINK HC indoor unit

Transmission & Transport Networks

6

MINI-LINK TN

Microwave radio function

• 19 modems per subrack in AMM 20p

• 5 modems per subrack in AMM 6p

• 2 modems per subrack in AMM 2p

• Software configurable traffic capacity

4/22109-FGC 101 190/1 Uen Rev.B

7

Transmission & Transport Networks

MINI-LINK TN

Traffic routing function

• Cross connection at 2Mbit/s level

• 400 E1 ports non blocking switching capacity, full duplex

• Software-controlled from management system

• Hardware redundant switching function nxE1

4/22109-FGC 101 190/1 Uen Rev.B

8

Transmission & Transport Networks

MINI-LINK TN

Traffic routing function

Conventional solution

4/22109-FGC 101 190/1 Uen Rev.B

9

Transmission & Transport Networks

MINI-LINK TN

Traffic routing function

MINI-LINK TN

4/22109-FGC 101 190/1 Uen Rev.B

10

Up to 70% size reduction

Transmission & Transport Networks

MINI-LINK TN

Circuit Management

Enables full benefits of MINILINK TN’s traffic handling capabilities

Highly efficient Operation and Maintenance

Integrated network planning, test & design tools

Continuous performance monitoring

Connections handled by world-class manager

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

11

MINI-LINK TN

Circuit Management

Operation and maintenance

Visibility of all media

Fault management on trunk level

Fault management on circuit level

Fault reporting with all network details

Automatic circuit routing by selecting the end points only

Facilitates changes in circuit capacity and end point relations

4/22109-FGC 101 190/1 Uen Rev.B

12

Transmission & Transport Networks

MINI-LINK TN

Circuit Management

Network design and planning

Excellent support for network planning

Build and route traffic for future expansions using the existing network information

Ask the database how traffic can be routed

Test automatic recovery

Perform transmission analysis

Continuous performance monitoring

Complete fault history

Continous performance monitoring

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

13

MINI-LINK TN

STM-1 Terminal Multiplexer function

Efficient interface between optical and microwave network

• Terminates full STM-1 payload

• Electric and optical interfaces

• MSP 1+1 for equipment and line protection

W

SDH ADM

E

4/22109-FGC 101 190/1 Uen Rev.B

14

Transmission & Transport Networks

MINI-LINK TN

STM-1 Terminal Multiplexer function

Complete MINI-LINK microwave solution for 155 Mbit/s

• One management system to manage the complete site

• One installation team for the complete site

4/22109-FGC 101 190/1 Uen Rev.B

15

Transmission & Transport Networks

MINI-LINK TN

Ethernet function

• Broadband to everyone

• Easy to make money

• Proven product

Public WLAN

ADSL

RSS

ADSL

WDSL

RSS

4/22109-FGC 101 190/1 Uen Rev.B

16

DSLAM

Fiber/CWDM

Transmission & Transport Networks

MINI-LINK TN

Ethernet function

• Capacity flexibility

2-34 Mbit/s

2 Mbit/s increments

• Carrier class Ethernet

Low Delay, 1-2ms

High throughput with small packages

Priority queuing (optional)

• Transparent Ethernet transport

Transparent for VLAN tags

No MAC address filtering

• Powerful Management

4/22109-FGC 101 190/1 Uen Rev.B

17

Transmission & Transport Networks

MINI-LINK TN

Ethernet function

• Ethernet bridge according to IEEE 802.1D with exception for self learning bridge and spanning tree

• Support for auto-negotiation of speed and duplex according to IEEE 802.3u

• Support for flow control according to IEEE 802.3x

• Auto MDI-MDIX (switching of Rx and Tx)

• Shielded RJ45 connectors with LEDs for network link, activity and rate selection

4/22109-FGC 101 190/1 Uen Rev.B

18

Transmission & Transport Networks

MINI-LINK TN

Protection

Microwave Propagation protection

(Hot-/working standby)

Redundant system architecture

Separate traffic and control system

Line & equipment protection

(1+1 E1 SNCP; MSP 1+1; Microwave 1+1)

Ring protection; 1+1 E1 SNCP

(media independent)

4/22109-FGC 101 190/1 Uen Rev.B

19

Transmission & Transport Networks

MINI-LINK TN

Protection

1+1 Microwave radio protection

• Physical link and equipment protection

• Hot or working standby

MINI-LINK TN

2-17xE1

Modem function

Modem function

Switch function

4/22109-FGC 101 190/1 Uen Rev.B

20

MINI-LINK E

Modem function

Modem function

Switch function

Transmission & Transport Networks

MINI-LINK TN

Protection

MSP 1+1

• Physical link and equipment protection

• Uni-directional

• Permanently bridged

• Non-revertible

4/22109-FGC 101 190/1 Uen Rev.B

Local equipment failures

External commands

Controller Detected failures

63xE1

STM-1 plug-in unit

STM-1 plug-in unit

Passive

STM-1

SDH equipment with

MSP 1+1

Active

STM-1

21

Transmission & Transport Networks

MINI-LINK TN

Protection

1+1 E1 SNCP

• Network layer protection on E1 level

• Physical link and equipment protection

• Signal is transmitted on two interfaces, receiver chooses the best of the two

• Switches on signal failure

4/22109-FGC 101 190/1 Uen Rev.B

22

Subnetwork

MINI-LINK TN

Working

Standby

Transmission & Transport Networks

MINI-LINK TN

Protection

1+1 E1 SNCP – Ring Application

• Microwave rings of 17xE1, 32xE1 and 64xE1 capacity

• Media independent

• Support for asymmetric ring capacity

• Independent of MSP1+1 and 1+1 microwave protection

PDH or SDH

Microwave nxE1

4/22109-FGC 101 190/1 Uen Rev.B

23

1+1 E1 SNCP

1+1 E1 SNCP nxE1

Working connection

Standby connection

Transmission & Transport Networks

MINI-LINK TN

Protection

Protected System Architecture

• Redundant power bus and power supply

• Redundant traffic buses

• Separate traffic- and control system

– Tolerance for control system faults.

– Hot insert/Hot swap of plug-in units

– Software upload without disturbing traffic

4/22109-FGC 101 190/1 Uen Rev.B

24

Transmission & Transport Networks

MINI-LINK TN

Synchronization

• PDH

– Unstructured E1 circuits with independent timing

• SDH

– E1s are mapped into VC12s at each Terminal

Multiplexer using asynchronous mapping

– MINI-LINK TN complies to G.825 for all jitter/wander requirements

– When building networks with MINI-LINK TN and MINI-LINK HC, local oscillator and loop timing is used

SDH network

Loop timing

Loop timing

MINI-LINK

TN

Local oscillator

4/22109-FGC 101 190/1 Uen Rev.B

25

Loop timing

Local oscillator

MINI-LINK

TN

Loop timing

Local oscillator

MINI-LINK

TN

Transmission & Transport Networks

MINI-LINK TN

Co-siting function

• Traffic interfaces : E1(x2); E2(x2); E3+E1

• DCN output ports: E0(x2)

• Terminal server: V.24

MINI-LINK TN

Co-siting function

4/22109-FGC 101 190/1 Uen Rev.B

MINI-LINK E

Modem function

26

E0 (x2)

E1 (x2)

E2 (x2)

E3 (x1)

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

• Fault management

• Configuration management

• Performance management

• Software management

• Equipment handling

• Loop functions

• Bit Error Rate Testing

4/22109-FGC 101 190/1 Uen Rev.B

27

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Fault Management/Fault localization

• All hardware and software is monitored

• Errors are mapped down to faulty replaceable unit

4/22109-FGC 101 190/1 Uen Rev.B

28

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Fault Management/LED:s

Green LED = Power On

Red LED = Faulty unit

Yellow LED = Plug-in unit ready for removal

Plug-in unit front

4/22109-FGC 101 190/1 Uen Rev.B

29

All plug-in units have a Board

Removal Switch (BRS) for controlled removal .

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Fault Management/User I/O

• 3 user input

– Configurable to normal open or normal closed

• 3 user output

– Both normal open or normal closed available

– Can be set manually by management system or configured to map to a given alarm severity

MINI-LINK Manager

Input to

MINI-LINK TN

MINI-LINK TN

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

30

MINI-LINK TN

Operation & Maintenance

Configuration Management

• Performed in Embedded Element

Manager or by using SNMP interface

– Transmission interface parameters

– Traffic routing

– Traffic protection

– DCN configuration

– User I/O configuration

– Security parameters

• Configuration is stored non-volatile on MINI-LINK TN

• Configuration can be backed up and restored from FTP server

4/22109-FGC 101 190/1 Uen Rev.B

31

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Performance Management

• Measurements according to ITU G.826

• 15 minutes and 24 hours current intervals

• 1x24 hours previous and 96x15 minutes intervals

• Configurable thresholds for current

PM data. Crossing of the thresholds is reported as alarms

4/22109-FGC 101 190/1 Uen Rev.B

32

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Software Management

• MINI-LINK TN software can be upgraded while in operation (without disturbing traffic)

• Software download can be done on site or from the O&M center

• FTP is used to transfer software

• New plug-in units are upgraded automatically if they have incorrect software revisions

4/22109-FGC 101 190/1 Uen Rev.B

33

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Equipment Handling

• Plug-in units can be inserted, swapped and removed while in operation

• When changing a circuit board for repair, the new board automatically receives the configuration of the old board

• Equipment fault management with supervision of temperature, power, fan, system buses and processes

4/22109-FGC 101 190/1 Uen Rev.B

34

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Equipment Handling/Temperature Monitoring

• The temperature of all circuit boards is monitored with sensors

• Two levels of temperature violations

– High temperature threshold shuts down the circuit board’s control software without disturbing the traffic

– Excessive temperature threshold shuts down the entire circuit board

Temp.

Excessive temp.

• Alarm notification on temperature violations High temp.

Normal temp.

Temp.

Supervision

Hysteresis

Excessive temp.

threshold

High temp. threshold

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

35

MINI-LINK TN

Operation & Maintenance

Bit Error Rate Tester (BERT)

• ITU standard O.151

• Replaces external line testers

• Enables system verification

• Remote activation/de-activation

• One BERT (E1) per Plug-In Unit

4/22109-FGC 101 190/1 Uen Rev.B

MINI-LINK TN

R

T

B

E

36

Plug-in unit

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Loop functions/Line Loop

MINI-LINK TN

Transmission link

R

T

B

E

MINI-LINK TN

Plug-in unit

4/22109-FGC 101 190/1 Uen Rev.B

37

AIS-Alarm

Indication Signal

Transmission & Transport Networks

MINI-LINK TN

Operation & Maintenance

Loop functions/Local Loop

MINI-LINK TN

Transmission link

R

T

B

E

MINI-LINK TN

Plug-in unit

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

38

MINI-LINK TN

Operation & Maintenance

Loop functions/Connection Loop

MINI-LINK TN

Transmission link

R

T

B

E

MINI-LINK TN

Plug-in unit

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

39

MINI-LINK TN

Data Communication Network

• IP based DCN

• SNMP v1, v2, v3

• IP router integrated in every node supporting OSPF

• IP over unnumbered PPP over radio hop and SDH overhead channels

• Automatic set up of DCN channels

MINI-LINK TN terminal server functionality for access to MINI-LINK E sub-networks

4/22109-FGC 101 190/1 Uen Rev.B

40

Transmission & Transport Networks

MINI-LINK TN

Data Communication Network

Ethernet or 2Mbit/s connection

MINI-LINK TN

128 kbit/s connection

MINI-LINK

Manager

Multiplexer/Repeater section

MINI-LINK TN

MINI-LINK

HC

1.2 kbit/s connection MINI-LINK E, (cluster)

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

41

MINI-LINK TN

Data Communication Network

Internal OSPF router/Default IP Address

• Unnumbered IP interfaces

– Less IP addresses consumed

– Ethernet and PPP interfaces inherit the default IP address for the node

– Simple planning of IP addresses

– Less manual configuration

• Numbered IP interfaces

– Provided when advanced OSPF routing functions are needed

– Set-up using standardized

Command Line Interface (CLI)

Inherits the default IP address

MINI-LINK TN

DCN Router

Default IP Address/OSPF Area

PPP interface

PPP interface

PPP interface

PPP interface

Ethernet interface

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

42

MINI-LINK TN

Data Communication Network

Internal OSPF router/Serial Interfaces PPP

• DCC Radio Terminal

– 128 kbit/s to MINI-LINK TN (automatically set up)

– 1.2 kbit/s to MINI-LINK E

• DCC STM-1

– Default bandwidth automatically established to 192 kbit/s in RSOH/MSOH

– Configurable to 384/576 kbit/s in RSOH/MSOH

– Automatically set-up between nodes

• DCC E1

One unstructured E1 used for DCN

This PPP channel has to be established manually.

• DCC 2x64 kbit/s

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

43

MINI-LINK TN

Data Communication Network

Internal OSPF router/Ethernet Interface

• 10 Base-T

• Shielded 8-pin RJ45

4/22109-FGC 101 190/1 Uen Rev.B

44

Transmission & Transport Networks

MINI-LINK TN

Data Communication Network

DCN Services (Optional)

IP DCN

FTP NTP DNS-DHCP

4/22109-FGC 101 190/1 Uen Rev.B

MINI-LINK TN

10 Base-T

LCT

45

Ethernet

Transmission & Transport Networks

MINI-LINK TN

MINI-LINK Management philosophy

Centralised Management

MINI-LINK Manager/MINI-LINK Connexion

Northbound management interfaces to existing systems

SNMP

4/22109-FGC 101 190/1 Uen Rev.B

46

Local on-site management

Embedded Element Manager

Transmission & Transport Networks

MINI-LINK TN

Centralized Management

Efficient tools for management on node and circuit level

Fault Management

Performance Management

Configuration Management

Inventory Management

Remote Software Upgrade

Security Management

System Administration

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

47

MINI-LINK TN

Centralized Management

MINI-LINK Manager - Common platform for microwave transmission

Single point of entry for all Ericsson microwave products

Integration of circuit alarm information from MINI-LINK Connexion

High network availability

Fast and accurate information

Grow as network expands

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

48

MINI-LINK TN

Centralized Management

MINI-LINK Connexion

Network Editor - Build and display network elements graphically

Network Router - Create and manage circuits throughout the network

Circuit simulator - Simulates alternative routes and topologies

Fault Manager - Fault monitoring, reporting and filtering services

Performance Manager - Provides information on availability and network load

Macro Manager - Enables faster repetitive actions

4/22109-FGC 101 190/1 Uen Rev.B

49

Transmission & Transport Networks

MINI-LINK TN

Centralized Management

MINI-LINK Manager

Minimum configuration

• One workstation/server (HW)

• RTU/RTC (SW)

Standard configuration

• One or several workstations (HW)

• One or several servers (HW)

• RTU/RTC (SW)

MINI-LINK

Connexion

Circuit Connection

Management

4/22109-FGC 101 190/1 Uen Rev.B

MINI-LINK

Manager

Network Element

Management

50

MINI-LINK

Connexion

Circuit Connection

Management

MINI-LINK

Manager

Network Element

Management

Transmission & Transport Networks

MINI-LINK TN

Centralized Management

MINI-LINK Connexion

Minimum configuration

• One workstation/DB server (HW)

• One Com server(HW)

• RTU/RTC (SW)

• Up to 25 MINI-LINK TN

Standard configuration

• One workstation (HW)

• Two servers, Com and DB (HW)

• RTU/RTC (SW)

• Up to 500 MINI-LINK TN

MINI-LINK

Connexion

Circuit Connection

Management

4/22109-FGC 101 190/1 Uen Rev.B

MINI-LINK

Manager

Network Element

Management

51

MINI-LINK

Connexion

Circuit Connection

Management

MINI-LINK

Manager

Network Element

Management

Transmission & Transport Networks

MINI-LINK TN

Northbound Management interfaces

SNMP

• Industry standard SNMP interface supporting v1, v2, v3

• Available in network elements as well as from MINI-LINK Manager

• A management option when using own integrated management systems

• Active alarm list and notification log for synchronization with management system

SNMP traps

SNMP get Notification log and current alarm list

NMS

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

52

MINI-LINK TN

Local Management

Embedded Element Manager

• EEM is accessed with standard web browser

– Installation and configuration

– Fault location

– Performance Management

– Local software upgrade

– Launch of MSM for radio management of MMU2 and SMU2

• CLI Interface: Industry-standard configuration of the DCN router

4/22109-FGC 101 190/1 Uen Rev.B

53

LCT

MINI-LINK TN

EEM

Transmission & Transport Networks

MINI-LINK TN

• Functionality Overview

– Microwave radio function

– Traffic routing function

– Circuit Management

– STM-1 Terminal Multiplexer function

– Ethernet function

– Protection mechanisms

– Synchronization

– Co-siting function

– Operation & Maintenance

– Data Communication Network

– Management Tools

• Product Overview

4/22109-FGC 101 190/1 Uen Rev.B

54

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

• Magazine height 44 mm

• Two full height slot positions for modems

• Mandatory configuration includes

AMM 2p magazine and NPU2

• Fan unit required in certain scenarios

4/22109-FGC 101 190/1 Uen Rev.B

55

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Node Processor Unit for AMM 2p (NPU2)

• Centralized node processor with DCN router,

SNMP Master Agent etc.

• E1 interfaces for connection to co-located BTS

• 10/100 BASE-T Ethernet interface for management and traffic

• USB interface for local maintenance

4/22109-FGC 101 190/1 Uen Rev.B

56

4x2 Mbit/s

(120ohm)

+24/-48 VDC

USB

10/100 BaseT

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

E1 Line Termination Unit (LTU 12x2)

• Used for additional E1s when NPU2

(4E1s) is insufficient

• 12xE1 interfaces, 120 Ohm G.703

4/22109-FGC 101 190/1 Uen Rev.B

57

4x2 Mbit/s

(120ohm)

4x2 Mbit/s

(120ohm)

Leds

4x2 Mbit/s

(120ohm)

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

• Magazine height: 150 mm

• Two half height positions for power and fan unit

• One full height slot dedicated for node processor

• Five full height slot positions for any plug-in unit

• Mandatory configuration includes AMM 6p magazine,

NPU1, PFU2 and FAU2

4/22109-FGC 101 190/1 Uen Rev.B

58

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Power Filter Unit 2 (PFU2)

• -48V DC input on PFU2

• +24V DC via external converter

• Redundant power unit available

Fan Unit (FAU2)

• Integrated fan unit for AMM 6p

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

59

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

• Magazine height: 300mm

• Two half height positions for protected or unprotected power

• One full height slot dedicated for node processor

• Nineteen full height positions for any plug-in unit

• Mandatory configuration includes AMM 20p magazine,

NPU1 and PFU1

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

60

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Fan Unit 1 (FAU1)

• Used for cooling in the AMM 20p

• Three fans for redundancy

• Two power interfaces for redundancy

• Alarm interface towards PFU1

4/22109-FGC 101 190/1 Uen Rev.B

61

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Power Filter Unit 1 (PFU1)

• Half size to accommodate two units in one full-height position

• Two PFU1s configured for redundancy

• Alarm interface towards FAU1

• -48V DC input on PFU1

• +24V DC via external converter

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

62

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Node Processor Unit for AMM 6p/AMM 20p (NPU 8x2)

• Centralized node processor with DCN router,

SNMP Master Agent etc.

• 10 BASE-T Ethernet interface for management

• E1 interfaces for local add-drop

• User In-/Output signals

4/22109-FGC 101 190/1 Uen Rev.B

63

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Modem Unit (MMU2)

• C-QPSK modulation

• Software-configurable capacity; 4-34 Mbit/s

• Compatible over the air with MINI-LINK E

• 1+1 protection via SMU2

4/22109-FGC 101 190/1 Uen Rev.B

64

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Modem Unit (MMU2 C)

• C-QPSK/16 QAM modulation agilitiy

• Software-configurable capacity; 8-64 Mbit/s

• Compatible over the air with MINI-LINK E*

• 1+1 protection without SMU2

* In C-QPSK mode

4/22109-FGC 101 190/1 Uen Rev.B

65

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Switch Multiplexer Unit (SMU2)

• Triple function plug-in unit

• Two MMU2s and one SMU2 for 1+1 protection

• External channelized 34 Mbit/s interfaces

• Co-siting interfaces with MINI-LINK E

4/22109-FGC 101 190/1 Uen Rev.B

66

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

E1 Line Termination Unit (LTU 16x2)

• Used for additional E1s when NPU

8x2 is insufficient

• 16xE1 interfaces, 120 Ohm G.703

4/22109-FGC 101 190/1 Uen Rev.B

67

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

STM-1 Line Termination Unit (LTU 155)

• Terminal multiplexer function

• 63xVC12s terminated to E1s

• MSP1+1 protection

• LTU 155 e/o and LTU 155 e

4/22109-FGC 101 190/1 Uen Rev.B

68

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Traffic termination/Pre-fabricated cables

• 120 Ohm, 6.0 meter pre-fabricated cables with one open end

• Connects direct to Sofix interfaces on NPUx/LTUx

• Easy way to connect to existing patch panels on site

4/22109-FGC 101 190/1 Uen Rev.B

69

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units / Accessories

Traffic termination/Interface panels

• Sofix interface conversion

• 120 Ohm/DSUB and 75 Ohm/SMZ

• Particularly useful for 75 Ohm applications

ICF1 120 Ohm for AMM 20p

4/22109-FGC 101 190/1 Uen Rev.B

ICF2 120 Ohm for AMM 6p

70

ICF16x2 120 Ohm for LTU16x2

Transmission & Transport Networks

MINI-LINK TN

Hardware components

AMM 2p / AMM 6p / AMM 20p / Plug-in Units /

Accessories

Outdoor solution for AMM 2p/AMM 6

• Easy to install

• Reliable

• Flexible

4/22109-FGC 101 190/1 Uen Rev.B

71

Transmission & Transport Networks

MINI-LINK TN

Hardware components/Summary

Magazines

2p

6p

20p

Plug-in units

• Power unit

• Node Processor

• Switch and co-siting interface

• Line Terminal Unit

• STM-1 Terminal Mux

• Modem Unit 4-34

• Modem Unit 8-64

4/22109-FGC 101 190/1 Uen Rev.B

Transmission & Transport Networks

72

MINI-LINK TN

Hardware components/Summary

4/22109-FGC 101 190/1 Uen Rev.B

73

MMU2 (Modem Unit)

SMU2 (Switch Multiplexer Unit)

LTU 16x2 (Line Termination Unit)

LTU 155 (Line Termination Unit)

NPU (Node Processor Unit)

PFU (Power Filter Unit)

Transmission & Transport Networks

MINI-LINK TN

Microwave transmission from an end-to-end perspective

Any frequency, capacity and modulation

Nodes designed for networks

Fixed, mobile and broadband applications

Efficient Management Systems

4/22109-FGC 101 190/1 Uen Rev.B

74

Transmission & Transport Networks

MINI-LINK TN

Summary

• Platform for next generation microwave networks

• Lower your network cost, while improving capacity and control

• Managed by MINI-LINK Manager

4/22109-FGC 101 190/1 Uen Rev.B

75

Transmission & Transport Networks

Download