Welcome to our World of Energy Storage Device Test Systems Who is Maccor ? Maccor specializes in the design and manufacture of high performance test systems for batteries, fuel cells and supercapacitors. First test system built in 1983. Largest, most experienced company worldwide, for the testing of small batteries of all chemistries. Head office and primary manufacturing facilities in Tulsa, Oklahoma, USA. Approximately 100 people and US$12 million in sales per year, with representation in many countries. What Does Maccor Equipment Do ? Maccor equipment is used to determine the quality and performance of various energy storage devices by applying simulated loads under computer control. This is achieved with synchronization of control and measurement, and with a high level of accuracy. Typical Tests Performed Cycle Testing under Constant Current, Constant Voltage, Constant Power, Constant Resistance loads. Pulse Discharge Tests such as GSM, CDMA, Multiple Slot and Multiple Current level. Cyclic Voltametry. AC Impedance measurements. Frequency Response Analysis. Formation of Lithium Cells. Applications Materials Research. Product Development. Product Manufacturing. Quality Control. Product Qualification. Cell Sorting. Application Testing. Why Purchase a Maccor System? Quality: proven by the long term reliability of all Maccor systems in use today. Features: the most comprehensive set of features with upgrades to address new applications. Performance: highest accuracy, speed, reliability and capabilities of any system. Support: considered by our customers as the best in the industry. Experience: unequalled, resulting from many years of work with numerous applications worldwide. Products Series 4000, Model 2300, Model MC4, Secondary Battery Test Systems. Series 3500 and Series 3600 Primary Cell Test Systems. Series 5300 Lithium Cell Formation System. Model EDA Frequency Response Analyzer. Series 6000 Fuel Cell Test System. General Specifications (1) General Specifications (2) Typical System Functions The following screens provide examples of test procedures and results achieved for a number of standard experiments. Long Term Cycle Test Charge Profile Nickel Vs Lithium CC / CV Charge Lithium Ion Battery 4.3 4.1 CC Charge for NiMH Battery Constant Current 0.8 0.9 1 1.1 1.2 1.3 Time/h 1.4 1.5 1.6 1.7 V of NiMHCYC5.0014 I of NiMHCYC5.001 3.9 Voltage/V 3.8 Constant Current 3.7 3.6 Current Tapered 3.5 3.4 3.3 3.2 67.5 68 Time/h 68.5 69 V of Ltcycle2.002 I of Ltcycle2.002 Current/mA Time End Condition 560 540 520 500 480 460 440 420 400 380 360 340 320 300 280 260 240 220 200 180 Current/mA 1.48 1.47 1.46 1.45 1.44 1.43 1.42 1.41 1.4 1.39 1.38 1.37 1.36 1.35 1.34 1.33 1.32 1.31 1.3 1.29 480 460 440 420 400 380 360 340 320 300 280 260 240 220 200 180 160 140 120 100 80 60 40 Constant Voltage 4.2 Charge NiMH Cell with –dV Termination Voltage/V End of Charge 1.506 1.506 1.506 1.505 1.505 1.504 1.504 1.503 1.503 1.502 1.502 1.501 1.501 1.5 1.5 1.499 1.499 1.498 1.498 1.497 1.497 1.496 1.496 1.495 V of Dv1.006 Peak Voltage Charge Terminated 11.7 11.75 11.8 11.85 Time/h 11.9 11.95 GSM Pulse Discharge Test GSM Pulse Discharge 4.2 V of DEMO_GSMPLI02.002 4.1 Pulse Low 4 3.9 Voltage/V 3.8 3.7 3.6 3.5 3.4 Pulse High 3.3 3.2 3.1 3 7.2 7.4 7.6 7.8 8 8.2 8.4 8.6 Time/h 8.8 9 9.2 9.4 9.6 Multi-Slot and Multi-Level Pulses Cyclic Voltametry Cyclic Voltagram 10 Cycles NiMH I of ScanNiMH04.002 Voltage Scan 10 mV / S 1.4 2 V of ScanNiMH04.002 I of ScanNiMH04.002 1.38 1.36 3 1.34 1 1.32 1.3 1.28 0 2 Current/A Voltage/V 1.24 1.22 1.2 1.18 -1 1.16 1.14 1.12 -2 1 1.1 1.08 1.06 -3 1.04 1.02 1 50 1 0 60 70 80 Time/min 90 100 1.05 1.1 1.15 1.2 Voltage/V 1.25 1.3 1.35 1.4 Current/A 1.26 AC Impedance Data Analysis yticapaC .sV egatloV egrahcsiD 00.92 00.82 00.72 00.62 00.42 00.32 00.22 00.12 00.02 000,21 000,01 000,8 000,6 000,4 hAm/yticapaC .CNI ,ROCCAM 000,2 0 V/egatloV 00.52 Frequency Response Analysis 1 Frequency Response Analysis 2 Formation, Single Cell Data File End of Formation Report Sales and Service Available in many countries. Technical advice on the best system for your needs. Assistance with your application. System commissioning. Operator and maintenance training. Free after sales telephone/fax/ e-mail support for the life of the product. For Sales and Service Contact USA / Canada: Korea: Maccor Inc. Korea Thermo-Tech, Inc. Phone: + 918-446-1874 Fax: + 918-445-1496 Email: sales@maccor.com Phone: + 82-2-431-1491 Fax: + 82-2-431-1494 Email: kthermo@yahoo.co.kr Singapore: China: Achema Pte Ltd Smart Technology Ltd. Phone: + 65-356-9081 Fax: + 65-356-9082 Email: achema@magix.com.sg Phone: + 86-10-6831-6810 Fax: + 86-10-6831-6760 Email: manager@smt.com.cn Europe: Israel: BMMS Ltd. WeisScientific Ltd. Phone: + 44-1858-46-8438 Fax: + 44-1858-46-8439 Email: sales@bmms.co.uk Phone: + 972-396-69391 Fax: + 972-396-56781 Email: weis@netvision.net.il Taiwan: India: Formosa EMV Techrico Corp. Con-Serv Enterprises Phone: + 886-4-2230-1212 Fax: + 886-4-2236-3848 Email: twemv@ms19.hinet.net Phone: + 91-22-5913743 Fax: + 91-22-5913743 Email: conserv@vsnl.com Summary The equipment, features, and capabilities of Maccor, extend beyond that described above. For further information or assistance with your application, please contact Maccor direct or one of our international representatives. Thank you for taking the time to view this presentation.