MegaTron Selling Points2

advertisement
MegaTron
and
MegaTrons SS
Water Treatment’s
Most User Friendly
Web Capable Controllers
Menu and Keypad
•User friendly ATM menu
•16 lines of information
•20 button keypad
•Set everything from keypad
System Approach
•
MegaTron “system” approach for 1 to 4 independent systems
•
MegaTron SS for single system control
•
•
•
•
•
•
•
•
•
Conductivity
Temperature
pH
ORP
2 water meter inputs
Flow switch input
5 additional digital inputs
Up to 5 chemical feed timers
Make-up conductivity (on full size MegaTron)
Conductivity Control
• 1 Point Calibration
• Bleed Limit Timer
• Cycles Control with Make-up
Conductivity
• Boiler sampling: Continuous,
Timed, Sample and Hold
ORP and pH
•
Set point control including individually set alarms and limit
timers
•
ORP interlocked with a 28-day timer
•
pH feed interrupted by other chemical feed timers
•
LSI or RSI values displayed
Chem Feed Timers
• Pulse Timer with Accumulator
• Percent Timer
• Post Bleed % Timer with Limit
• Limit Timer
• 28-day Timer
Auxiliary Flow Meter Inputs
•
Auxiliary flow meter inputs are
available to track various flow meter
devices like the FloTracker in a
metering pump’s discharge line.
•
Historically track chemical or water
usage with low level alarms, no flow
alarms for pump loss prime or no
bleed off flow.
•
Maintain a set PPM for chemical
feed by tracking chemical cycles of
concentration, make-up water and
chemical addition.
Relay Flexibility
•
The main box holds up to 10 relays and the controller can
control up to 20 relays with 11-20 housed in additional boxes.
•
What activates each relay can be defined by the user from all
of the available control functions on the unit. This means you
can have pH monitoring but not have a relay assigned to it.
•
Multiple functions can be set
to activate a relay or force it
off, allowing for special
control logic.
Service Notepad
Each of the up to 4 systems have 10 Service Notepad items for
storing user entered data such as testing results that can have
a user defined name, number range, unit of measure, high
alarm, low alarm and time interval alarm for the next expected
manually enter data.
The Service Notepad can be
used to enter manually tested
readings like chemical residual,
raw water chemistry, hand held
tester
readings
into
the
MegaTron. The MegaTron will
then keep a record of them for
history reporting and alarming.
Water Meter Inputs
•Each system card can have 2 water meter
inputs. Each will store the hourly average
for the past 24 hours, the daily average for
the past 60 days reviewable at the unit via
the onboard history plus have a running
total.
•Systems with two active water meter
inputs can calculate evaporation with that
value also stored in history.
•The Units of Measure can be set for
Gallons per Contact or Pulses per Gallon
allowing for easy configuration for paddle
wheel or contacting head meters.
4-20 mA
•
MegaTron units can have eight 4-20mA inputs and MegaTron SS
three. All have a user defined unit of measure, number range,
name, set point, high alarm and low alarm and can activate a
relay.
•
Common 4-20mA inputs are level, corrosion, fouling, flurometer
and other special sensors or monitors.
•
MegaTron can have up to six 4-20mA outputs, MegaTron SS
three with the user selecting the source from all analog inputs.
Digital Inputs
• 1 Flow Switch input per system card. Choose activation
(open / closed), limit probe alarm outputs to only when system
has flow and select if timers can run with or without flow.
• 5 Digital Inputs can be given a custom name and can activate
or deactivate relays.
Customization
Customers can put in custom names for:
• Unit
• Systems
• Relays
• Digital Inputs
• Notepad Items
• 4-20 mA Inputs
On Screen History
See history graphs or logs on screen:
• Probe Inputs
• Water Meters
• Daily Evaporation
• Alarm Activation
• Relay Activation
• Keypad Activity
WebAdvantage and the World Wide Web
Keep You in Constant Contact
• 128 Bit Encryption Server
Security
• Back-up Assured History
Storage
• No Proprietary Software to
Load
• Log in From Any Computer
with Internet Access
• Email Notification of Alarm
Events
Web Connections Options
•
Ethernet card with a CAT 5 cable for static or DHCP internet
connection.
•
External cellular router connects back to the controller’s
Ethernet card.
•
Built-in phone modem for dial-up Internet provider (ISP) like
EarthLink and a phone line.
•
BACnet
•
MODbus
Web Based Remote Monitoring
•One Step Connection
•View Current Readings
•Change Settings
•Manage Users
•History Graphs and Logs
•Create Custom Reports
•Set-up Auto Reporting
One Step Connection
•
Use any Computer with
Internet Access
•
Summary Page Review
•
Pick From All of Your
Units with One
Connection
Check Readings / Change Settings
•
Review Current Conditions
•
Change Any Setting
•
Enter Notepad or Service
Report Data
Manager Users
•
Set-up Access to
Controllers
•
Manage Access Levels
•
Manage Alarm Email
Notifications
eService or LXF Integration
•
T3-Web Reports
•
Activate our exporting
•
PIN number
•
Daily data transfer
•
Instrument data displayed
History and Auto Reporting
•
Create Custom Reports
• Establish Auto Report Intervals
• View Any Data
Prefabricated Systems
•
Convenient installation
•
Professional
appearance
•
Customizable
•
Saves time & money
Product Support
Advantage support is the best in the industry!
•
Nine regional sales representatives
• Five factory based customer services representatives
• IT and engineering support
• Proprietary engineered features
• 2-year replacement warranty on Advantage made
products
• We pay return shipping costs
MegaTron
and
MegaTron SS
Water Treatment’s
Most User Friendly
Web Capable Controllers
Any Questions?
Download