Introduction to Electromechanical Systems Instruction Manual for Package Sorting System Patrick Thompson, Zack Mullins, Matt Folsom December 13, 2011 Table of Contents I……………………………………………Theory of Operation…………………………Pg.3 II…………………………………………Description of Operation……………Pg.4-5 III………………………………………Operation Instructions…………………Pg.6 IV…………………………………………Trouble Shooting…………………………………Pg.7-10 V……………………………………………Parts List…………………………………………………Pg.11 VI…………………………………………Appendix………………………………………………………Pg.12-13 Theory of Operation The package sorting system operates based on the size of the package. With the system plugged into 120VAC, 60HZ, and with switch 1 and switch 2 in the on position, the conveyer belt rotates towards the small package sorting area and the photocell exciter lamp activates. The conveyer belt will move a package past two sets of photocells that control the large and medium package sorting areas. If the package is large enough to simultaneously cover the photocells of the large sorting area then it will be sorted as a large package by a momentary burst of air. If the package is large enough to simultaneously cover only the photocells of the medium sorting section then, it will be sorted as a medium package by a momentary burst of air. If the package is too small to cover either set simultaneously then it will be sorted at the end of the conveyer belt as a small package. Photocells Large Solenoid Coil (N.O.) Valve Large Conveyer Photocell Drive Exciter Motor Lamp Photocells Medium Solenoid Coil (N.O.) Valve Medium Operation Instructions .Plug system into 120VAC, 60HZ. .Switch S1 to the on position. .Hold S2 in on position for 3 to 5 seconds and then release. .Ensure conveyer belt rotates towards the small package sorting area. .Ensure all packages initially pass through large sorting area .wait for all of the packages to clear off the conveyor belt .turn S1 to the off position Trouble Shooting Problem 1. No power to the system. Cause .Not plugged into 120V.A.C 60HZ. .Replace S1. .F1 is blown. .Replace F1 that is rated for 3A 250V. .Not Connected to 120VAC 60HZ .Florescent tube is bad .S2 is bad 3. Conveyor Motor(M1) will not rotate conveyer belt .Plug into 120V.A.C 60HZ. .S1 is bad. .Bad connection to 120VAC or ground 2. Exciter lamp (L1) will not light. Solution .Conveyor Motor is not connected to 120VAC 60hz .Check for broken wires from 120VAC to S1 from S1 to Ground .Check for broken wires from 120VAC to Exciter Lamp, Exciter Lamp to ground .Change florescent tube .Replace S2 .Check wires from 120VAC to M1 and from M1 to ground .Conveyor Motor to Conveyor belt coupler is disconnected or broken 4. D.C. power supply not supplying 6.8VDC .If disconnected, properly reconnect coupler device. If broken replace the coupling device .No voltage on .check for broken primary of wires from 120VAC to transformer(T1) or no primary of T1 and power from the from T1 to ground. secondary to anode Check for broken wire from line of .Diode(D1)is secondary to anode destroyed of D1 .Resistor(R1)has changed its value from 1K ohms to a .Replace with diode specified in parts list and assure that greater value or the diode is biased capacitor(C1)has properly before become permanent open power is applied .Zener Diode(D2)has been destroyed .Transistor(Q1)has been destroyed .Replace R1 and C1 with components specified in parts list .Replace D2 with zener diode specified in parts list .Replace Q1 with transistor specified in parts list 5. Solenoid Valve 1 (N.C.)(SV1) activates when one photocell(PC1 or PC2) is covered 6. Solenoid Valve 2 (N.C.)(SV2) activates when one photocell(PC3 or PC4) is covered 7. Solenoid Valve 1 (N.C.)(SV1) .PC1 or PC2 is dirty .PC1 and PC2 are in series with each other .The sensitivity adjust for the circuit is not adjusted correctly .PC3 or PC4 is dirty .PC3 and PC4 are in series with each other .The sensitivity adjust for the circuit is not adjusted correctly .Broken wire from 120VAC to N.O. CR2A .Clean the photo cells then then make sure SV1 operates correctly .Place PC1 in parallel with PC2 then make sure SV1 works properly .Adjust Sensitivity adjust(R3)until SV1 works correctly .Clean the photo cells then then make sure SV2 operates correctly .Place PC3 in parallel with PC4 then make sure SV2 works properly .Adjust Sensitivity adjust(R6)until SV1 works correctly .Find the break in the wire with an ohm will not activate or from CR2A to SV1 meter and repair the or from SV1 to ground problematic section .corroded contacts on .clean the contacts N.O. CR2A with small file 8. Solenoid Valve 2 (N.C.)(SV2) will not activate .CR2 will not energize .see problem shooting tip #9 .Broken wire from 120VAC to N.O. CR4A or from CR4A to SV2 or from SV2 to ground .Find the break in the wire with an ohm meter and repair the problematic section .corroded contacts on .clean the contacts N.O. CR4A with small file 9. Relay CR2 does not energize .CR4 will not energize .see problem shooting tip #10 .Broken wire from 120VAC to N.O. CR1A or from CR1A to CR2 or from CR2 to ground .Find the break in the wire with an ohm meter and repair the problematic section .corroded contacts on .clean the contacts N.O. CR1A with small file 10. Relay CR4 does not energize .CR1 will not energize .see problem shooting tip #11 .Broken wire from 120VAC to N.O. CR3A or from CR3A to CR4 or from CR4 to ground .Find the break in the wire with an ohm meter and repair the problematic section .corroded contacts on .clean the contacts N.O. CR3A with small file 11. Relay CR1 does not energize .CR3 will not energize .see problem shooting tip #12 .Sensitivity adjust R3 is not adjusted correctly .cover PC1 and PC2 then adjust R3 until CR1 energizes .PC1 or PC2 are shorted .block PC1 and PC2 from light and check for resistance. The .Diode D3 is not in photocell with the the circuit correctly lowest resistance at this point is the .Transistor Q2 is shorted one. Remove destroyed the short from that photocell and adjust the circuit until CR1 energizes .remove Q2 from the circuit and test. If bad the replace with transistor specified in the parts list 12. Relay CR2 does not energize .Sensitivity adjust R6 is not adjusted correctly .make sure D3 is reverse biased .cover PC1 and PC2 then adjust R3 until CR1 energizes .PC3 or PC4 are shorted .block PC1 and PC2 from light and check for resistance. The .Diode D4 is not in photocell with the the circuit correctly lowest resistance at this point is the .Transistor Q3 is shorted one. Remove destroyed the short from that photocell and adjust the circuit until CR1 energizes .remove Q2 from the circuit and test. If bad the replace with transistor specified in the parts list .Make sure D4 is reverse biased