Matthew W. Keller Mechanical Option Private Residence Avon, Colorado Outline - Existing Building - Project Overview - Existing Mechanical System - Alternate Designs - Passive Solar Architecture - Radiant Floor Cooling - Site-Generated Energy - Conclusions - Acknowledgements - Questions Existing Building Project Overview - September, 2003 - $13.4 Million Finish Areas Garage Mechanical Crawlspaces Decks/Patios/Walkways TOTAL - $550/ft2 - Project Players - Rader Engineering, Inc. 12,043 ft 2 1,200 ft2 1,459 ft2 3,796 ft2 5,993 ft2 24,491 ft2 Existing Mechanical System - Intent: - “Incorporate state of the art technologies into proven mechanical systems and equipment to achieve the ultimate comfort control system.” - 58 radiant floor zones - 16 fan coils - 10 w/ hot water coils - 15 w/ dx coils - 15,845 ft2 exterior radiant - Future Expansion Existing Mechanical System Existing Mechanical System - Humidification - 7 steam humidifiers - Total capacity- 41.5 lbs/hr - Energy Suppliers - Electricity- Holy Cross Energy - $0.05/kWh plus demand and customer charge - Natural Gas- Xcel Energy - $0.0977/Therm plus service and facility charge - Initial Cost - $1,452,042.00- $120.57/ft2 finished area Alternate Designs - Intent - Increase sustainability - Decrease purchased energy consumption - Maintain comfort control and aesthetics - Strategies - Add Passive Solar Features - Utilize Radiant Flooring Year Round - Utilize more site-generated energy Passive Solar Architecture - Clerestories - Glazing Selection - Thermal Capacity Passive Solar Architecture - Clerestories - Winter Angle Master Bed. - =90-(Lat.+23.5)=26.5 - Summer Angle Kitchen - =90-(Lat.-23.5)=73.5 His Office Passive Solar Architecture - Design Loads Heating (MBH) Cooling (MBH) Org. 280.3 284.8 New 294.6 296.1 W/shades 294.6 284.5 Passive Solar Architecture - Increased Envelope Roof Stone Wall Wood Wall Glazing Total Ft2 400 270 470 281 $/Ft2 6 20 8 30 $ 2400 5400 3760 8430 $19,990 Passive Solar Architecture - Glazing 400 350 300 - Design Loads MBH 250 Cooling 200 Heating 150 100 50 0 O-E P-E P-S1 P-S5 - Passive Performance Arch Orig. Pass. Pass. Pass. Glazing Existing Existing Sngt 100 Sngt 500 U 0.36 0.36 0.31 0.35 SC 0.49 0.49 0.59 0.70 F Sol. 0.41 0.46 0.57 0.56 F Mech. 0.59 0.54 0.43 0.44 Passive Solar Architecture - Thermal Capacity - Phase Change Wallboard - Paraffin wax infused - Cp=9.5 Btu/lb*F - Melts ~ 76 F - 14,000 ft2 (5/8”) - 423 MBTU/Deg.F increase - $14,000 cost increase - Effect on Passive Performance Glazing Existing Sngt 100 Sngt 500 U 0.36 0.31 0.35 SC 0.49 0.59 0.70 F 0.46 0.57 0.56 F (ph-ch) Increase 0.47 0.01 0.61 0.04 0.63 0.07 Passive Solar Architecture - Annual Operating Cost Arch Orig. Pass. Pass. Pass. Glazing Existing Existing Sngt 100 Sngt 500 Heating $197 $199 $155 $155 Cooling $1,483 $1,424 $1,690 $1,867 Total $2,907 $2,827 $3,196 $3,491 Savings -$80 -$289 -$584 Radiant Floor Cooling - Less Forced Air Required - < Fan Energy - < OA Load - Decreases MRT - Allows Higher DB Setpoint - < Forced Air - > Free Cooling Radiant Floor Cooling - Capacity - 1.23 Btu/hr*ft2*F - 16 Btu/hr*ft2 - Minimum Floor Temp: 66 F - DB Setpoint: 79 F Radiant Floor Cooling - New Mechanical System (pass w/ S1) - Cooling load - 293.6 MBH (from 305.3 MBH) - DX Fan Coils and Condensing Units eliminated - New Equipment - Fan Coils - Absorption Chiller - Increased Heat Rejection - Modified Operation (2-Pipe) Radiant Floor Cooling - Increased Heat Rejection - Required - 746.3 MBH (Chiller: 307.3 MBH of mechanical cooling) - 102.6 MBH (Pool dehumidifiers, pending total enclosure of pool) - Available - 686.4 MBH (Existing Cooling tower) - Supplemental - 162.5 MBH of heat rejection is needed Radiant Floor Cooling - Supplemental Heat Rejection - Two radiant zones under exterior water feature - Designed for 17 GPM and 30 Deg. Temperature drop - 162.5 MBH rejection achieved with a 21.8 Deg. Temperature drop Radiant Floor Cooling - New Operation/Schematic Radiant Floor Cooling - Two-Pipe System Evaluation - Initial cost - +$25,400.00 - Absorption Chiller $60,000 - Annual Operation Cost System Original New Heating $155 $69 Cooling $1,690 $658 - Simple Payback = 20 years Total $3,196 $1,926 Radiant Floor Cooling - Radiant Cooling Benefit - Outdoor Air Load Mechanical System Total Space Load (MBH) Rad. Capacity (MBH) Supplemental Load (MBH) CFM CFM (OA) OA load (MBH) Orig. 293.6 -293.6 18821 1882 23 New 293.6 151.6 142 9103 910 11 Site-Generated Energy - Solar Water Heating - Solar Electricity Generation Hot Water Collection - Evacuated Tubes - Arrays of 20 &30 - 580 tubes (ft2) - 1500 gallon storage Hot Water Collection - System Comparison Collector Area Collector Cost Output MMBTU Output Therms Saved Therms* Annual Savings Simple Payback (yrs) Orig. 350 $7,320 118.1 1181 1389 $136 54 New 580 $40,600 277.1 2771 3260 $319 127 *Assumes 85% seasonal boiler efficiency Electricity Generation - Grid Connected - Shell ST40’s - 40 Watt output 40 panels 40 degree slope 2 dummies Cost Daily Gen. (kWh) Yearly Gen. (kWh) Yearly Savings Simple Payback (yrs) $17,900 6 2192 $110 163 Conclusions - Passive Redesign - Clerestories would be better suited to a climate with no cooling season - Thermal capacity benefit - Radiant Cooling - Use flooring year round - 2-Pipe saves energy - Site-Generated Energy - Evacuated tube $ increase outweighs performance benefits - PV’s not cost effective in existing grid Thanks to… - Drew Rader - President of Rader Engineering - Prof. Stanley Mumma - Primary Faculty Consultant - Fariborz Mahjouri - Thermo Technology Rep. - Mark McCray - RMS Electric Managing Director