Petri Torniainen, October 2009 New ABB industrial drive module ACS850-04 overview © ABB Group March 14, 2016 | Slide 1 New industrial drive modules Industrial drives Very flexible drives that are easy to be configured to meet the needs of various industries and applications Designed especially for process industry segments such as: © ABB Group March 14, 2016 | Slide 2 Pulp & paper Mining Cement Chemical, oil & gas Examples of applications: Cranes Winders Mixers New industrial drive modules For System Integrators and OEMs ACS850-04 is designed for fast, cost effective installation and integration into cabinets, therefore targeted for OEMs and System Integrators © ABB Group March 14, 2016 | Slide 3 New industrial drive modules Range © ABB Group April 2009 | Slide 4 New industrial drive modules Range © ABB Group March 14, 2016 | Slide 5 New industrial drive modules Frames A & B Dim. in mm I2N (A) PN (kW) Type 3 1.1 ACS850-04-03A0-5 3.6 1.5 ACS850-04-03A6-5 4.8 2.2 ACS850-04-04A8-5 6 2.2 ACS850-04-06A0-5 8 3 ACS850-04-08A0-5 364 3 Kg 93.5 197 (219)* 380 5 Kg Frame B, IP20 I2N (A) PN (kW) Type 10 4 ACS850-04-010A-5 14 5.5 ACS850-04-014A-5 18 7.5 ACS850-04-018A-5 *Depth in brackets = with control panel 101 © ABB Group March 14, 2016 | Slide 6 Frame A, IP20 274 (297)* New industrial drive modules Frames C & D Dim. in mm 567 276 (298)* I2N (A) PN (kW) Type 25 11 ACS850-04-025A-5 30 15 ACS850-04-030A-5 35 18.5 ACS850-04-035A-5 44 22 ACS850-04-044A-5 50 22 ACS850-04-050A-5 16 Kg 166 567 22 Kg 276 (298)* 221 © ABB Group March 14, 2016 | Slide 7 Frame C, IP20 Frame D, IP20 I2N (A) PN (kW) Type 61 30 ACS850-04-061A-5 78 37 ACS850-04-078A-5 94 45 ACS850-04-094A-5 *Depth in brackets = with control panel New industrial drive modules Frames E & E0 Dim. in mm 602 354 (376)* 276 35 Kg I2N (A) PN (kW) Type 103 55 ACS850-04-103A-5 144 75 ACS850-04-144A-5 *Depth in brackets = with control panel 700 443 (465)* © ABB Group March 14, 2016 | Slide 8 67 Kg 312 Frame E0, IP20 Frame E, IP20 I2N (A) PN (kW) Type 166 90 ACS850-04-166A-5 202 110 ACS850-04-202A-5 225 110 ACS850-04-225A-5 260 132 ACS850-04-260A-5 290 160 ACS850-04-290A-5 New industrial drive modules Frame G Dim. in mm 1564 568 205 Kg © ABB Group March 14, 2016 | Slide 9 562 Frame G, IP00 I2N (A) PN (kW) Type 430 200 ACS850-04-430A-5 521 250 ACS850-04-521A-5 602 315 ACS850-04-602A-5 693 355 ACS850-04-693A-5 720 400 ACS850-04-720A-5 New industrial drive modules Ratings © ABB Group April 2009 | Slide 10 New industrial drive modules Ratings © ABB Group March 14, 2016 | Slide 11 Currents are expressed in Amperes I2N rated current available continuously without overloading ILd continuous current in light-duty use IHd continuous current in heavy-duty use IMax maximum output current New industrial drive modules Ratings Supply voltage : 3-phase 380 V to 500 V © ABB Group March 14, 2016 | Slide 12 New industrial drive modules Hardware © ABB Group April 2009 | Slide 13 New industrial drive modules Hardware Optimized for cabinet installation Bus cc © ABB Group March 14, 2016 | Slide 14 Compact, narrow design Side-by-side mounting DIN-rail mounting (frames A and B ) Power terminals on top (up to 45 kW) enabling compact and EMC compliant installation Motor connections at the bottom of the drive Plug-in terminals I/O Power terminals (frames A and B ) New industrial drive modules Hardware © ABB Group March 14, 2016 | Slide 15 2 option slots for I/O extensions and encoders 1 dedicated slot for fieldbus modules Coated boards as standard Fan supervision (frames A to D) New industrial drive modules Hardware Removable memory unit © ABB Group March 14, 2016 | Slide 16 Stores the complete software and parameter settings Makes the recommissioning of the unit fast and easy Gives a possibility for software and parameter configuration at e.g. ABB or OEM workshop before sending it to customer Easy to install (only a screwdriver is needed !) New industrial drive modules EMC filters C2 and C3 (1st and 2nd environment) C3 filter, frames A-B C3 filter, frames C – G Optional built-in EMC filter In frames C and D possibility to retrofit afterwards (a separate “lid” in the cover) C2 filter, frames A – D External filter C2 filter, frames E0 & E © ABB Group March 14, 2016 | Slide 17 External filter connected directly to the power terminals Optional built-in EMC filter New industrial drive modules Chokes for harmonic filtering © ABB Group March 14, 2016 | Slide 18 Frames A and B: optional, external, AC side Frames C and D: standard, built-in, DC side Frames E0,E and G: standard, built-in, AC side New industrial drive modules Common DC bus R R © ABB Group March 14, 2016 | Slide 19 R R Standard ACS850 feature Allows energy savings due to the capability to use regenerated energy from a motor into another Possibility to regenerate energy from one or several ACS850 to other ACS850 drives in the DC link Supports the management of one or several braking choppers (integrated in the drive) R R New industrial drive modules Dynamic braking options Braking choppers In a common DC system several choppers can operate simultaneously Braking resistors Available for different kind of pulse duty performance Equipped with a thermal sensor as standard Option / Frame © ABB Group March 14, 2016 | Slide 20 A-D E0-G Built-in braking chopper Standard Option (+D150) Braking resistor External option External option New industrial drive modules Hardware configuration © ABB Group April 2009 | Slide 21 New industrial drive modules Standard configuration Without control panel © ABB Group March 14, 2016 | Slide 22 New industrial drive modules Assistant control panel , option +J400 Assistant control panel © ABB Group March 14, 2016 | Slide 23 Option + J400 With real time clock Incl. control panel holder in the unit Can be attached either to the control unit cover or to the cabinet door New industrial drive modules Control panel holder, option +J414 Control panel holder on the unit © ABB Group March 14, 2016 | Slide 24 Option +J414 Incl. control panel holder No control panel The dummy control panel has 2 LEDs that indicate the status of the drive New industrial drive modules Control panel and a door mounting kit, option +J410 Control panel holder on the door © ABB Group March 14, 2016 | Slide 25 Includes control panel Includes control panel holder Includes IP54 kit Includes 3 meter cable No control panel holder in the unit New industrial drive modules No control unit cover, option +0C168 No control unit cover © ABB Group March 14, 2016 | Slide 26 Option + 0C168 No control panel holder in the unit No control panel New industrial drive modules Safe Torque-Off © ABB Group April 2009 | Slide 27 New industrial drive modules Safe Torque-Off Safe Torque-Off (STO) as standard SIL 3 (IEC 61508) / Safety category 4 (EN954-1) ACS850-04 © ABB Group March 14, 2016 | Slide 28 New industrial drive modules Operating conditions © ABB Group April 2009 | Slide 29 New industrial drive modules Operating conditions Temperature: -10°C to 55°C G frame up to 50°C Derating above 40°C Relative humidity: Max. 95%, no condensation allowed Altitude: Up to 4000 m At Class 3M4 acc. to EN60721-3-3 Climatic / environmental conditions: © ABB Group March 14, 2016 | Slide 30 1%/100 m derating above 1000m Vibration: 500V up to 2000 m Class 3K3, 3C2 acc. to EN60721-3-3 New industrial drive modules Cables © ABB Group April 2009 | Slide 31 New industrial drive modules Cable lengths Max. length of the STO cable is 25 m © ABB Group March 14, 2016 | Slide 32 Longer cable can be made by using extra relays Max. length of the D2D link is 50 m New industrial drive modules Interfaces © ABB Group April 2009 | Slide 33 New industrial drive modules Control board JCON-11 Pin XPOW Name 1 24Vin 2 GND XRO1 1 RO1NO 2 RO1COM 3 RO1NC XRO2 4 RO2NO 5 RO2COM 6 RO2NC XRO3 7 RO3NO 8 RO3COM 9 RO3NC XD24 1 2 3 4 24VD 24VD DGND DGND XDI 1 2 3 4 5 6 A DI1 DI2 DI3 DI4 DI5 DI6 DIIL XDIO XAI XAO XD2D XSTO 1 DIO1 2 DIO2 1 VREF+ 2 VREF3 AGND 4 AI1+ 5 AI16 AI2+ 7 AI2AI SEL JUMPER AI1 AI2 1 AO1+ 2 AO13 AO2+ 4 AO2Term. Jumper 1B 2A 3 BGND 1 2 3 4 Control interface 1. Control voltage supply External supply (24VDC) input for the control unit (to be used, if external power supply is required) 2. Digital I/O 6xDI (DI 6 can be used also as a thermistor input), 2xDI/O (can be used also for pulse train inputs or outputs, max 32 kHz; DI/O can be separated as separate group and used either as a npn/pnp input), 3xRO 3. Analog I/O 2xAI (mA or V), 2xAO (1xmA) 4. DIL input Drive interlock input 5. RS-485 link Galvanically isolated, can be used for D2D or Modbus 6. Safe Torque Off (STO) Designed for Safety Integrity Level 3 (SIL 3) acc. to IEC 61508 and Safety Category 3 acc. to EN 954-1 7. User interface (HMI) PC-tools and control panel connection (RJ45). Can be used also as a Modbus link for monitoring 8. Removable memory unit (RMU) Complete drive configuration and settings are stored in the memory unit. OUT1 OUT2 IN1 IN2 © ABB Group March 14, 2016 | Slide 35 New industrial drive modules Drive to drive link Fast communication between drives Baud rate: 8 Mbit/s Cable length: ~ 50 m RS-485 Flexible data communication between drives Master/follower communication © ABB Group March 14, 2016 | Slide 36 1 Master – several followers Multicast communication Master/follower(s) Follower/follower(s) New industrial drive modules Optional I/O © ABB Group April 2009 | Slide 37 New industrial drive modules Option slots 1 and 2 Options Data Install in Analogue & digital extension 1 FIO-01 4xDI/O, 2xRO FIO-11 3xAI (mA/V), 1xAO (mA), 2xDI/O FIO-21 1xAI (mA/V), 1xAO (mA), 1XDI, 2xRO Slot 1 or 2 Feedback interface 2 FEN-01 2 inputs (TTL incremental encoder), 1 output * FEN-11 2 inputs (SinCos absolute, TTL incremental encoder), 1 output * FEN-21 2 inputs (Resolver, TTL incremental encoder), 1 output* FEN-31 1 input (HTL incremental encoder), 1 output Slot 1 or 2 * When this module is used, the lower part of the control unit cover cannot be used © ABB Group March 14, 2016 | Slide 38 New industrial drive modules Option slot 3 Options Data Install in Communication FPBA-01 PROFIBUS-DP, DPV0/DPV1 FCAN-01 CANopen FDNA-01 DeviceNet FENA-01 EtherNet/IP Modbus TCP Later on also PROFINET I/O FSCA-01 Modbus FLON-01 LONWorks (comes later) Slot 3 3 © ABB Group March 14, 2016 | Slide 39 New industrial drive modules Software © ABB Group April 2009 | Slide 40 New industrial drive modules Software - DTC DTC with enhanced features © ABB Group March 14, 2016 | Slide 41 Standard sw supports asynchronous motors and permanent magnet motors Output frequency up to 500 Hz Low motor noise mode Improved stand still ID run New industrial drive modules Software LOC ASSISTANTS 2 Start-up Assistant Easy start-up Macros: preprogrammed parameter settings Start-up Assistant Motor Set-up Application Speed control EXT1 Speed control EXT2 EXIT 16:31 SEL © ABB Group March 14, 2016 | Slide 42 Easy use Intuitive parameter structure Short/long parameter menus I/O “mapping” List of changed parameters Flexibility Extensive parameter settings Limited block programmability as standard New industrial drive modules Software – Backup and restore LOC MAIN MENU PAR BACKUP I/O SETTINGS REF EDIT CANCEL 16:31 EDIT Panel backup/restore functionality Creating and uploading the backup file from drive to panel Showing backup file info LOC PAR BACKUP MAKE BACKUP TO PANEL (1) Restoring all parameters EXIT LOC 16:31 SEL PAR BACKUP SHOW BACKUP INFO RESTORE PARS ALL RESTORE PARS NO-IDRUN RESTORE PARS IDRUN RESTORE ALL USER SETS EXIT © ABB Group March 14, 2016 | Slide 43 16:31 SEL Versions etc. Incl. ID Run and motor data (2) Restoring all parameters except ID Run and motor data (3) Restoring only ID Run and motor data (4) Restoring all user sets New industrial drive modules Software – Fault loggers LOC FAULT LOGGER 36: LOCAL CTRL LOSS 06.11.08 09:59:27 15: SUPPLY PHASE 17: ID-RUN FAULT 31: SAFE TORQUE OFF EXIT 16:31 DETAIL LOC Fault logger can hold the information of 10 latest faults. Fault information includes: LOCAL CTRL LOSS TIME 9:59:27 FAULT CODE 36 FAULT CODE EXTENSION EXIT LOC 16:31 DIAG PAR BACKUP Check parameter ’30.03 Local ctrl loss’ setting. Check PC tool or panel connection. EXIT © ABB Group March 14, 2016 | Slide 44 16:31 OK Fault message + fault code Time stamp Fieldbus fault code Status word Output frequency, speed estimated, torque, current, DC voltage, torque limit status But no warnings New industrial drive modules Software – Short/long parameter menus Short/long parameter menus Only the most important parameters for commissioning are shown as a default parameter set (21 parameter groups) User can freely activate the long menus in order to see all parameters LOC 1601 1602 1603 1615 P16.15: Load short/Load long PARAMETERS Local lock Parameter lock Pass code Menu set sel No request EXIT 16:31 EDIT © ABB Group March 14, 2016 | Slide 45 LOC PAR EDIT 1615 Menu set sel Load long [2] CANCEL 16:31 SAVE New industrial drive modules Software – List of changed parameters LOC MAIN MENU CHANGED PAR FAULT LOGGER LOC CHANGED PAR 1616 Menu set active TIME & DATE 2005 Maximum current EXIT LOC 16:31 ENTER 1.70 A 2202 Acc time1 2203 Dec time1 EXIT 16:31 List of changed parameters (panel view ”CHANGED PAR”) List of parameters that have been changed from default Parameter values in changed parameter list can be modified EDIT MAIN MENU PAR CHG LOG PARAMETERS LOC LAST CHANGES 2001 Maximum speed ASSISTANTS 1650 rpm EXIT 16:31 ENTER 28.10.08 13:50:16 EXIT © ABB Group March 14, 2016 | Slide 46 16:31 List of changed parameters (panel view ”PAR CHG LOG”) List of 10 latest changes with date and time stamps Parameter values in parameter changed log can be modified EDIT New industrial drive modules Software – I/O mapping I/O settings info in control panel shows usage of I/O LOC The connections between I/O and different software functions are shown. When selecting channel name (e.g. DI1) information about channel’s source is displayed. When selecting parameter (e.g. 1002 Ext1 start in1) parameter value can be changed. LOC MAIN MENU I/O SETTINGS REF EDIT LOC I/O SETTINGS DRIVE INFO Analog outputs EXIT 16:31 Analog inputs Digital I/Os Digital inputs Relay outputs EXIT 16:31 © ABB Group March 14, 2016 | Slide 47 ENTER SEL I/O SETTINGS DI1 1002 Ext1 start in1 DI2 DI3 1010 reset sel LOC FaultI/O SETTINGS EXIT 16:31 EDIT DI1 1002 Ext1 start in1 DI2 DI3 1010 Fault reset sel EXIT 16:31 EDIT LOC I/O INFO NUM OF I/O ITEMS 1 SLOT NUMBER 0 LOC NUMBER PAR EDIT NODE 1002 Ext1 start in1 EXIT 16:31 DI1 [P.02.01.00] CANCEL 16:31 SEL New industrial drive modules Software – Autotuning © ABB Group March 14, 2016 | Slide 48 Autotuning updates automatically new tuning values for speed controller Proportional gain Integration time Four possible tuning modes : Smooth (slow response) Middle Tight (fast response) User (bandwidth, damping) Speed controller autotuning runs the specific speed curve for finding the tuning values New industrial drive modules Software – Time levels Extended speed controller functionality Speed controller at 500 s time level Reference handling at 2 ms time level 23.05 Acc comp der time 23.06 Acc comp filt time 500 s d dt 03.05 Speed ref ramped TAccCom 03.06 Speed ref used 20.01 Maximum speed 23.11 Speed win func 23.12 Speed win hi 23.13 Speed win low 03.08 Acc comp torq PID + + 03.07 Speed error filt 23.01 Proport gain 23.02 Integration time 23.03 Derivation time 23.04 Deriv filter time 20.02 Minimum speed 23.08 Speed additive 0 06.02 bit 14 Ramp out zero 06.02 bit 12 Ramp in zero 23.15 PI adapt max sp 23.16 PI adapt min sp 23.17 Pcoef at min sp 23.16 Icoef at min sp 01.01 Speed act 23.07 Speed err ftime x 23.14 Drooping rate © ABB Group March 14, 2016 | Slide 49 23.09 Max torq sp control + 03.09 Torq ref sp control 23.10 Min torq sp control New industrial drive modules Software – Load analyzer Consists of 2 independent loggers: 1) Amplitude logger (AL): 200 ms sampling time interval. 2) Peak value logger (PVL): records peak values of a selected signal. The data of the two loggers can be restored after a power failure as it is stored to non-volatile memory Percentage of operating time When the new peak value is detected, also some other actual signals (speed, current, dc voltage) are saved. 10 % 20 % 30 % 40 % 50 % 60 % 70 % Amplitude logger range © ABB Group March 14, 2016 | Slide 50 80 % 90 % 100 % New industrial drive modules Software – Maintenance assistance © ABB Group March 14, 2016 | Slide 51 Reminds the user of the need of maintenance 6 individual counters – parameter group 44 Gives alarm for needs such as : cooling fan change, cabinet fan change, DC capacitor change, motor bearings… New industrial drive modules Software – Energy efficiency counter Energy savings calculation As an output you can get: Total energy savings in kWh Total energy savings in euro or in other currency Total energy savings in CO2 Energy optimizer © ABB Group March 14, 2016 | Slide 52 Reduces motor magnetizing current at low mechanical loads New industrial drive modules Software - Timers © ABB Group March 14, 2016 | Slide 53 4 timers can be used to control the drive (like drive start/stop command) Start/Stop daily Start/Stop weekly New industrial drive modules PC tools © ABB Group April 2009 | Slide 54 New industrial drive modules DriveStudio Commissioning, tuning and monitoring tool © ABB Group March 14, 2016 | Slide 55 Parameters setting and signal monitoring Data logger and on-line signal monitoring Backup and restore Context sensitive helps Start-up and Diagnostic Assistants New industrial drive modules Drive SPC Programming tool © ABB Group March 14, 2016 | Slide 56 Drive Solution Program composer For function block programming PLC functions library Interface to Drive functions and parameters New industrial drive modules DriveSize © ABB Group March 14, 2016 | Slide 57 New industrial drive modules Documentation © ABB Group April 2009 | Slide 58 New industrial drive modules Documentation © ABB Group March 14, 2016 | Slide 59 Standard with every drive : Quick installation and start-up guides CD with full documentation Full paper format manuals available as an option To be ordered as a separate item Many customers are serial manufacturers or users and do not need / want piles of paper manuals