Precision experiments Electroweak precision experiments • • • • practical tools scientific: test of theoretical models, existing laws of physics confirm and/or constrain models potential to discover (interactions, particles, ...) measures in the distant past precision measurements: what do they provide? precision experiments part of large facilities precision experiments with neutrons proton decay measurements muon decay measurements neutron decay measurements lifetime experiment correlation parameters between neutron and decay products neutron electric dipole moment experiments precision experiments: measurement tools measures: a practical tool define a length on the basis of a common feature ~ 3400 BC 1 cubit Royal cubit stick Giza pyramids sides built on the basis of the cubit to a precision of 0.05%!!! precision experiments: measurements measurements: to add to academic interests deduce earth curvature by angle of sunlight 250 BC - Eratosthenes: • In Syene ~5000 stadia south of Alexandria sunlight shining directly down well shafts • in Alexandria light measured to be at 7 angle • ~5000 × 360/7 = 252,000 stadia (of the order of 40,000 km) - (cf 40,030 km) precision experiments: particle physics Scientific precision experiments: testing the limits of our description and understanding of nature particle physics: masses and lifetimes of particles (quarks, leptons, hadrons, ...) matrix elements of transitions (CKM, PMNS, nuclear trs, ...) forces and couplings in reaction processes (GF, , ... ) signals of rare events, breaking of laws and symmetries, ... goes hand-in-hand with ever more precision calculations • proton lifetime • neutron lifetime (Vud) • neutron decay • neutrinoless -decay precision experiments: proton decay Standard Model describes the change of quark colour and flavour and lepton conversion through gauge bosons g, W±, Z0 d u decay rate as function of energy T, coupling constant G: νe s 0 d u e- Λ u d u KGF2 T 5 gW2 GF 2 2 MW ( Baryon number B and lepton number L conserved ) p precision experiments: proton decay GUT mechanisms in models quarks and leptons incorporated into common families (e.g. e+ with d): • interaction with new gauge bosons (X, Y) • masses MX ~ 1015 GeV, coupling gU ~ 1/42 new allowed processes: p → π0 + e+ p { e+ d u u X p e+ - { Y d u u -u u } -u u 0 ( Baryon number B and lepton number L NOT conserved ) B L B Li } 0 i gU4 M 5p M 4 X p 1 1029 yr into specific channel: p e 1032 yr 0 precision experiments: proton decay Super kamiokande: neutrino oscillation experiment 11,200 PMTs detecting e and 50,000 tonnes of ultra-pure water, 1000m underground in the Kamioka Mine (100 km < L < 10,000 km) neutrino flavour states mix, neutrino’s are massive Super kamiokande: use data to look for proton decay events precision experiments: proton decay p → π0 + e+ 106 event triggers per day: • background from cosmic rays • flashing PMT’s • radioactivities 18816 surviving events: analyse all data to look for electron signals: • • • • in the correct energy range total invariant mass per event determined in the correct momentum range from the correct part of detector / B pe 8.2 1033 yr (90%CL) 0 precision measurement constraining GUT’s precision experiments: lepton g-2 gq S 2m S ,g 2 2 • 1927 Dirac intrinsic angular momentum and magnetic moment of electron quantified • measurements of g factors pushed further development of QED • May and November 1947 electron g factor measurement different from 2: g factor anomaly ae • Formulation of QED with first order radiative correction ae 0.00116 2 g 2 0.00119(5) 2 six orders of magnitude improvement in precision expts and theoretical calculation testing the Standard Model to its limits, discovery of new interactions beyond SM precision experiments: lepton g-2 Muon g-2 experiment Brookhaven target protons pions muons detectors muon decay to electron • 24 GeV proton focused on nickel target generates pions • pions decay to polarised muons and are injected in storage ring • decay electrons emerge preferentially in direction of muon spin • detect those electrons with high enough energy to be in the direction of the muon motion detecting a signal of the muon spin in forward direction signal oscillates with spin precession frequency of muon precision experiments: lepton g-2 Brookhaven National Lab: 3 GeV muons stored in 14 m dia. ring in 1.45 T field • muon has orbital motion in magnetic field at cyclotron frequency ωC • spin has precession frequency ωS • relative precession of S with respect to velocity of muon: ωS- ωC D S c a g 2 eB c a 2 mc g 2 2 direct relationship between ωD and a g eB eB eB S (1 ) c 2 mc mc mc precision experiments: lepton g-2 precision experiments: lepton g-2 first signs of deviation of 2.6σ from Standard Model description? March 2001 PRL not quite... error in experimental analysis code SM 11659100 six orders of magnitude improvement in precision expts opening a window to beyond SM physics phenomena 11659150 Experiment 11659200 a 10 10 11659250 precision experiments: neutron decay neutron beta decay experiment: • Standard Model precision measurements • precision tests on unitarity of the CKM matrix • cosmological significance 2 2 2 Vud Vus Vub 1 n p e e 782 keV neutron decay probability, function of particles momenta, spin, correlation coefficients pe p pe p p e p me dW 1 b a Pn A B D Ee Ee E E Ee E Ee precision experiments: neutron decay parameters neutron beta decay experiment: • correlation coefficients between particles spin and momenta • coupling constants 1 A 2 1 32 1 2 a 1 32 correlation electron and anti-neutrino momentum correlation electron momentum – neutron spin GA GV ratio axial-vector / vector coupling constant free neutron decay lifetime K n f nGV2 1 32 2 3 7 K 5 4 me c GV Vud GF from muon decay precision experiments: neutron correlation parameter experiments measurement of λ the “A” experiment: correlation electron momentum – neutron spin • polarised neutrons • electron detection with respect to neutron spin direction precision experiments: neutron correlation parameter experiments Spectra for both spin states 2002: result: 2006: result: A = -0.1189(8) = -1.2739(19) A = -0.1198(5) = -1.2762(13) testing the CKM matrix of Standard Model B. Maerkisch, PERKEO III : Neutron Decay Measurements precision experiments: neutron correlation parameter experiments measurement of λ the “a” experiment: correlation electron-neutrino momentum proton energy spectrum depends on a p • neutrons (unpolarised) • proton detection, energy measurement e neutrons energy ~ meV, energy release ~MeV n n e p e- proton energy depends on angle between electron and anti-neutrino e- precision experiments: neutron correlation parameter experiments measurement of proton energy spectrum • Penning trap • proton detection, energy measurement cold neutrons pass through volume between two electrodes, kept in a magnetic field decay protons trapped and orbit around magnetic field lines open trap by lowering voltage on gate electrode repeat sequence for mirror voltages ranging 0V to 800 V precision experiments: neutron correlation parameter experiments measurement of decay proton integrated energy spectrum fit curve to energy spectrum as function of a: a = -0.1054 ± 0.0055, λ = 1.271 ± 0.018 no competition for A measurement but independent method precision experiments: neutron lifetime experiments the neutron lifetime experiment: • neutrons (of cold or ultra-cold energy) • detect decay products or detect surviving neutrons • precision tests on unitarity of the CKM matrix • cosmological significance experiment at NIST - USA: • beam of cold neutrons • neutrons pass through penning trap • decay protons recorded precision experiments: neutron lifetime experiments the neutron lifetime experiment: NIST superconducting magnet 3T high voltage (27 kV) cage for proton acceleration incoming neutron beam solid-state charged particle detector precision experiments: neutron lifetime experiments • need to know neutron flux to very high precision • need to know trap volume to high accuracy the neutron lifetime experiment: NIST • need to know efficiency of detectors to high accuracy • need to collect many events for statistical precision neutron flux monitor: n + 6Li→3H + • ρ = (39.30 ± 0.10) µg/cm2 6Li density • σ = (941.0 ± 1.3) b absorption cross section at 2200 m/s • Ω/4π = 0.004196 ± 0.1% fractional solid angle detector τn = 885.5 ± 3.4 s. precision experiments: neutron lifetime experiments experiment at ILL: • • • • the neutron lifetime experiment: stored ultra-cold neutrons ultra-cold neutrons guided into storage chambers seal chamber and store neutrons for a period T open chamber to neutron detector and count remaining neutrons repeat cycle for different storage periods T two storage chamber configurations: different surface exposure UCN detector precision experiments: neutron lifetime experiments • need to know neutron flux stability the neutron lifetime experiment: stored ultra-cold neutrons • need to know neutron loss mechanism during storage • need to collect many events for statistical accuracy • different detection efficiencies for two chamber configurations ± 0.36 s • uncertainty in shape of chamber • statistical uncertainty precision experiments: neutron lifetime experiments experiment at ILL: • • • • the neutron lifetime experiment: stored ultra-cold neutrons ultra-cold neutrons guided into storage chambers seal chamber and store neutrons for a period T open chamber to neutron detector and count remaining neutrons repeat cycle for different storage periods T and different energies precision experiments: neutron lifetime experiments precision experiments: neutron lifetime experiments the neutron lifetime experiment: stored ultra-cold neutrons latest result too far off to be included in average, now additional measurement: • polarised ultra-cold neutrons guided into storage chambers • seal chamber and store neutrons for a period T • open chamber to neutron detector and count remaining neutrons • repeat cycle for different storage periods T precision experiments: neutron lifetime experiments measurements / error bars incompatible, to be continued... precision experiments: neutron lifetime experiments the neutron lifetime experiment: stored ultra-cold neutrons Vud from neutron and nuclear beta decay Vud 2 4908.7 1.9 s n 1 32 n = (878.5 0.7st 0.3syst) s “Gravitrap” result n = (885.7 0.7) s world average Perkeo result: A0 = -0.1189(7) = -1.2739(19) =GA/GV precision experiments: neutron electric dipole moment + - T reversal dn S - - dn S electric dipole moment dn Electric Dipole Moment: neutron is electrically neutral If average positions of positive and negative charges do not coincide: + spin S + - P transform. S dn + dn S P & T violation EDM dn CPT conservation CP violation CP violation in Standard Model generates very small neutron EDM Beyond the Standard Model contributions tend to be much bigger neutron a very good system to look for CP violation beyond the Standard Model nEDM: measurement principle Compare the precession frequency for parallel fields: Experiments: Measurement of Larmor precession frequency of polarised neutrons in a magnetic & electric field = E/h = [-2B0n - 2Edn]/h to the precession frequency for anti-parallel fields (d n ) 2ET N : polarisation product E: electric field T: observation time N: number of neutrons = E/h = [-2B0n + 2Edn]/h The difference is proportional to dn and E: h( - ) = 4E dn nEDM: measurement principle 1. “Spin up” neutron... 2. Apply /2 spin flip pulse... 4. Free precession ... Second /2 spin flip pulse. Ramsey Resonance Curve 24000 1/Ts 22000 neutron spin up count 3. 20000 18000 16000 14000 12000 10000 working points 29.7 resonance frequency 29.8 29.9 30.0 applied frequency [Hz] 30.1 nEDM at ILL: scheme used Four-layer mu-metal shield High voltage lead Coil for 10 mG magnetic field Quartz insulating cylinder Upper electrode Main storage cell Hg u.v. lamp PMT to detect Hg u.v. light Vacuum wall Mercury prepolarising cell RF coil to flip spins Magnet UCN polarising foil UCN detector Hg u.v. lamp S N UCN guide changeover Ultracold neutrons (UCN) nEDM at ILL: set-up room temperature experiment nEDM at ILL: normalised frequency measurement 29.9295 Neutron resonant frequency (Hz) 7.7890 29.9290 7.7888 29.9285 29.9280 10 -10 T 7.7886 29.9275 29.9270 7.7884 29.9265 7.7882 29.9260 0 5 10 Run duration (hours) 15 20 nEDM at ILL: performance room temperature experiment 100 d n 3 10 26 ecm neutron EDM [10 -25 e cm] 80 60 40 20 0 -20 -40 -60 1300 1400 1500 1600 run number 1700 1800 1900 nEDM: experiment vs theory Progress at ~ order of magnitude per decade Standard Model out of reach Severe constraints on e.g. Super Symmetry +e 1 cm -e Neutron EDM upper limit [ecm] Experiment Theory 10-19 10-19 10-20 10-20 10-21 10-21 10-22 10-22 10-23 10-23 10-24 10-24 10-25 10-25 10-26 10-26 10-27 10-27 10-28 1960 1980 2000 year of publication 10-28 10-29 10-30 dn = 1 ecm 10-31 |dn|< 3 x 10-26 ecm 10-32 10-33 10-34 10-35 precision experiments we have seen: precision measurements examples neutron electric dipole moment experiments neutron lifetime & correlation experiment anomalous g-factor (g-2) decay experiments (p, double beta) these can: current precision experiments: test of theoretical models, existing laws of physics confirm and/or constrain models potential to discover (interactions, particles, ...) mostly indirect measurements a very powerful tool to probe theories and their limits revealing signatures of new physics