Prof Awad S. Hanna
Designated by the letter “A” followed by the
American Society for Testing and Materials
(ASTM) designation number.
The principal types of structural steel include:
A36 carbon structural steel
A572 high-strength low-alloy structural steel
A588 corrosion-resistant high-strength low-alloy structural steel.
Prof Awad S. Hanna
Table 1, Rolled-steel shape designations
Type fo shape
W shape
S shape
M shape
American St andard Channel
Miscellaneous Channel
HP (bearing pile) shape
Equal leg angle
Unequal leg angle
Plat e
Example designat ion
W27 x 114
S20 x 95
M8 x 25
C12 x 30
MC 12 x 50
HP 14 x 8 9
L 6 x 6 x 1/2
L 8 x 4 x 1/2
PL 1/2 x 12
1”
Weight: 40.8 lb/sq. ft/ in
1’
1’
Prof Awad S. Hanna
C
8
= channel
= nominal depth weight = 11.5 #/Lf
Use:
beams and built-up members
Prof Awad S. Hanna
L = angle
5 = length of one leg
3 = length of another leg
5/8 = nominal thickness need to look up #
Bracing and build-up members
Prof Awad S. Hanna
Structural
WT 7 x 49.5
ST 9 x 35
WT = cut from wide flange
(14 x 90)
7 = nominal depth
49.5 = #/lf
ST = cut form S beam (18 x
70)
Use:
Build-up sections
Prof Awad S. Hanna
Wide Flange
W14 x 90
14 WF 90
W = wide flange
14 = nominal depth
90 = #/lf use: beam and column
Standard
Beam
S18 x 70
18 I 70
S
18 depth
70
= standard
= nominal
= #/lf use: beam, not column
Prof Awad S. Hanna
Nominally taken off and priced by weight
Group for take off by:
Grade of steel
Type of section or member
Method of tied connection
location
Maintain consistent sequence of take off.
Common:
Columns and detail
Beams and detail (floor by floor)
Bracing and flooring
Prof Awad S. Hanna
Depends on where material is purchased.
Mill price apply to large orders.
Warehouse price apply to small orders from local supplier.
Prices are as of time of delivery. Need escalation clauses to be clearly set forth.
Price is made up a base plus extras.
Prof Awad S. Hanna
Prices are expressed in cents per pound.
W14x95 - 32.68 ft, A36 steel (3104.6#)
Base
Dimension: shape
17.00
0.45
Pack
Mark
Load length-quantity 1.00
0.00
0.00
0.20
18.65
Prof Awad S. Hanna
W14x 43
Example Drawing for Structural Steel Take-Off
W14x 68 W14x 68 W14x 43
All Columns this Row
W24 x 68
W18 x 40
W18 x 50
W18 x 40
W18 x 70 W18 x 70
NOTE:
All columns are 12’0” in length
W18 x 70 W18 x 70
W14x 43
20’0”
W14x 68
30’0”
W14x 68
W18 x 40
W18 x 50
W18 x 40
W14x 43
20’0”
All Columns this Row
W24 x 100
All Columns this Row
W24 x 100
All Columns this Row
W24 x 100
N
All Columns this Row
W24 x 68
Table 2, List of Steel Quantities
Sect ion Number Lengt h (ft ) Tot al Lengt h Wt ./ft Tot al Wt . (lb)
W 14 x 43 4 20.0
8 0 43 3440
W 14 x 68
W 18 x 40
4
4
30.0
20.0
120
8 0
6 8
40
8160
3200
W 18 x 70
W 18 x 50
W 14 x 43
4
2
4
30.0
20.0
28.0
120
40
112
70
50
43
8400
2000
4816
W 14 x 43
W 18 x 84
W 18 x 84
W 14 x 103
W 24 x 68
W 24 x 100
4
4
4
2
10
14
14.0
28.0
14.0
28.0
12.0
12.0
56
112
56
56
120
168
43
8 4
8 4
103
6 8
100
2408
9408
4704
5768
8160
16800
The cost of plates and connectors (bolts or welding) are not included.
Prof Awad S. Hanna