ENGR 1181 Circuits Lab Introduction Lab 3 – Alternative Powerpoint (authored by Bruce Trott) Engineering Education Innovation Center College of Engineering ENGR 1181 Lab Safety Lab Rules • Closed Toed Shoes • No food or drink • Instructor/TA checking before testing • Turning off/on Breadboard • Checkout Sheet Signed Task 1: Basic Setup (Step 1) • Connect 5V power supply to the toggle switch box by plugging in the black wire • Next connect the red and black wires originating from the bread board sockets to their appropriate positions as shown: 5 V power supply Notice Red and Black wires connecting from +5V and Ground Posts. Make sure metal part of wires are touching metal posts. Task 1: Basic Setup (Step 2) • Connect the red and black probes to their appropriate Digital Multimeter (DMM) connections as shown in the figure below : Turn the DMM dial to the DCV setting to configure it as a voltmeter This is the standard configuration of Leads P. 4 ENGR 1181 Converting from Schematic to Physical Follow the Diagram Schematic Physical Layout +5 Volts +5 Volts +5 Volts +5 Volts Ground Ground Circuit Schematic Ground Task 3: Series Circuit, (Step 1) • Toggle off power to board. • Place the nominally valued 200 and 300 Ohm resistors on the Breadboard, as shown in the schematic (left) and in the picture (right). NOTE: Vertical location of resistors is critical. 3 2 Circuit Schematic An Equivalent Circuit Do you now •Different physical circuits can correspond to same logical understand the concept of metal circuit •An example of the same circuit in a different physicalstrips? layout P. 7 ENGR 1181 Common Problems • Misaligning resistors and wires • Not using calculated values for resistances • Not adding a resistor within the LED Circuit • Miscalculations More Common Problems • The power strip isn’t on • Ground the circuit • 3) LED are placed backwards (Short lead to ground) • 4) Halves of the boards aren’t being bridged • 5) Wires are missing from the main 5V power source *Never measure CURRENT using the DMM. The current should always be calculated from measured voltage and resistance values. ENGR 1181 Two - Person Teams Perform this lab in teams of 2 people. If there are only 3 people, all can work together. Record results in provided calculation sheet and perform calculations. • Topic Document Type Marble Delivery System None Quality and Productivity Executive Summary CIRCUITS EXECUITIVE SUMMARY Solar Meter -- Solar Cell Memo (Combined) Quality & Productivity Memo Wind Turbine 1 -- Wind Turbine 2 Report (Combined) Problem Solving Project 1 Problem Solving Project 2 Problem Solving Project 3 Project Notebook (Combined) ENG 1181