Antek ® 6200 Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation PAC Refinery Solutions Your Process. 2 PAC Refinery Solutions S S S S S/N S S/N S S S S S S S Your Process. Optimized. Ensure regulatory compliance Receive actionable total sulfur data 3 Product Description Antek 6200 Process On-Line Analyzer Meet strict regulatory standards for sulfur content in your high-value products • Total sulfur and total nitrogen analyzer for gas, LPG, and Liquid samples • Excellent repeatability and reproducibility over a wide range even during process swings • In tight correlation with primary test methods 4 Product Description Antek 6200 Dual-stream and dual-range analysis 6200 Series Sulfur UV 6200 Series Nitrogen High Speed Sulfur (HSS) 5 Key Advantages Meet strict regulatory standards for sulfur content in high-value products Produce lab accuracy with process robustness Optimize the process by keeping close to the specification limits Control operational and maintenance costs 6 Key Advantages Meet strict regulatory standards for sulfur content in high-value products • • • • Measure Total Sulfur, Total Nitrogen, or both in a single analyzer Precise measurement of gas, liquid, and LPG products Direct injection system capable of measuring heavy gas/oil products Sensitivity from 250 ppb to % levels 7 Key Advantages Produce lab accuracy with process robustness • Utilizing Proven Antek technologies with instruments running 24/7 in process and laboratory globally • Flexible combustion system performs under various process conditions • Customized sample conditioning systems available for optimal results for your specific application • Correlates to ASTM D4629 and D5453 8 Key Advantages Optimize the process by keeping as close to the specification limits as possible • Quick analysis in 2-5 minutes per stream • Fast response time to process changes – no carry over from products • Immediate and precise results for fast and reliable decisionmaking • Enables process control by easy integration with plant DCS 2000 1750 1500 mg/kg 1250 1000 750 500 250 0 9 Key Advantages Control operational and maintenance costs • Can use air or oxygen as the combustion gas, depending on the application • New pyrotube design extends preventative maintenance efforts • Reduced cycling intervals extends the life of the injection valve • Built to withstand process disruptions, and recovers quickly for minimal downtime 10 Antek 6200 Unique Analysis Unsurpassed Leadership • • • • High speed analysis Measures all products Direct injection Antek’s proven leadership 11 6200 Technology Analytical Process Flow Path SAMPLE CONDITIONING SSR SYSTEM Process SCS SCS Temperature Controller 1000 1000 Supply Pyro Gas Furnace Inlet Gas Return Pyro tube Sample Injection Valve Combusted sample Flow Control Pyro gas Inlet gas Carrier Membrane Dryer Dryer Dryer Vent Scrubber System Vent Sulfur Detector Pressure Switches Combustion Gas Carrier Gas Power Supplies Interface & Control UV & HV 13 Theory of Operation 14 6200 Specifications Specifications Method Compliance Certifications/Area Classifications Performance Communication Outputs Sampling Utility Requirements ASTM D5453, D6667, D4629, D5176, ISO 20846 ATEX Ex px ia IIC T4 Gb • Analytical Range: 200 ppb for Sulfur and 250 ppb for Nitrogen (lower detection limit) to % levels • Precision: within <1% of full scale, for most applications • Linearity: <1% of full scale at >1ppm concentrations • Analysis Time: 2 minutes; analyses over 1000 ppm may take longer • Cycle Time: 2 to 5 minutes, programmable • 4–20 mA isolated at 750 Ω (standard) • Discreet digital inputs and outputs for remote control and status indication • RS-232, RS-422, RS-485 for Modbus RTU (standard) • Modbus TCP/IP and Ethernet (optional) • • Injection valve, 2 or 5 µl sample volume; Sampling system available as recommended option • • • • • Carrier (Argon, Nitrogen*, Air): 99.975%, 50 psig, 5–15 cc/min Instrument or Plant Air/Oxygen for combustion (application dependent) Combustion gas (Oxygen, Air): 99.75%, 50 psig, 400 cc/min Plant Air (purge): clean, dry, particle-free; 80–100 psig Instrument Air: 80–100 psig, for injection valve operation and for pneumatic output to sample conditioning panel * Nitrogen cannot be used as carrier on a 6200 N Nitrogen system. 16 Theory of Operation- Total Sulfur 1 Pyro Oxidation of Sample • Sample is introduced into an oxygen rich environment and combusted @ >1000°C. – Sulfur species converted to SO2; – Hydrocarbons are converted to water vapor and CO2 CxHy-S-N + O2 (excess) = H2O+ CO2+O2+SO2+NO Or R- N + R-S + O2 CO2 + H2 O + NO + SO2 • Water vapor removed with membrane dryer – Reverse osmosis 17 Theory of Operation- Total Sulfur 2 Pyro UV fluorescence of Sulfur • Oxidized sample is exposure to UV light – SO2 Is converted to SO2* – On returning to stable state, energy is emitted as a flash of light which is measured by a photomultiplier tube – Amount of energy produces is directly proportional to the number of sulfur atoms in the sample SO2 + hv = SO2* = SO2 + hv 18 Theory of Operation – Total Nitrogen Pyro Chemiluminescence's of Nitrogen • Oxidized sample is Mixed with Ozone – NO Is converted to NO2* – On returning to stable state, energy is emitted as flash of light which is measured by a photomultiplier tube – Amount of energy produces is directly proportional to the number of bound nitrogen atoms in the sample NO + O3 NO2* NO2 + hv 19 6200 Results Sulfur in diesel sample Switching from 1800 to 400 mg/kg sulfur 2000 Concentration (mg/Kg S) 1800 1600 1400 1200 1000 800 600 400 200 0 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Injections (5 minute analysis) No sample carry over! 21 Sulfur Gasoline 20 ppm scale 7.5 ppm standard oxygen vs air Repeatable Measurements! 22 Sulfur Testing Diesel 20 ppm scale 7 ppm standard oxygen vs air Repeatable Measurements! 23 Measurement Stability DIESEL SAMPLE WITH 11.8 mg/kg SULFUR INJECTED 3048 TIMES OVER A PERIOD OF 10 DAYS. AVERAGE VALUE OF 11.7 ± 0.16 mg/kg ( 1.4 %RSD). 14 50 ppm full scale 13.5 13 mg/kg 12.5 12 11.5 11 10.5 10 0.00 1.01 2.01 3.02 4.03 5.03 6.04 7.05 8.05 9.06 10.07 Days 24 Sample Conditioning System A Sample Conditioning System (SCS) Removes Contaminants & Water, Regulates Sample Pressure, & Controls Sample Flow To Ensure Samples Introduction Under Constant Conditions. Sample Conditioning System Cal Standard Selection Cal 1 Cal 2 Stream or Calibration Selection Stream 1 Fast Loop Stream 2 Fast Loop Filtered sample Stream Selection Bypass flow Return to Process Low Pressure Header Flow Control Flow Indication Sample To Analyzer Sample from Analyzer 25 Typical Sample System 26 Summary • Total sulfur and total nitrogen analyzer for gas, LPG, and liquid samples – Analyzes a wide range of sulfur and nitrogen monitoring applications – Robust technology – Agreement with primary test methods • With its fast and accurate results, the 6200 helps refineries: – Protect catalysts – Meet regulations and optimization targets. 27 Cemtrex, Inc. 19 Engineers Lane Farmingdale, NY 11735 Tel: 631-756-9116 • Fax: 631-420-4985 mip.cemtrex.com • sales@cemtrex.com 28