Laboratory Glassware - Thermo Fisher Scientific

Choice & Convenience
Laboratory Glassware
Containerware • General Glassware
Volumetric Glassware • Interchangeable
Test, Culture & Specialty Tubes
A World of Choice for Glassware
Glassware is one of the staple products used in every laboratory and in this new
glassware catalogue, Thermo Fisher Scientific offers you a range and choice of
products which will suit every budget.
The catalogue showcases a host of leading glassware brands, offering you both
choice and convenience when selecting glassware for your laboratory. Quality
and precision are the hallmarks of the glassware range available from Thermo
Fisher, so irrespective of the brand you select you can be confident you will
receive quality products.
Readily available stock is an important factor when ordering glassware items. To
assist you in this process, the catalogue denotes those items which are generally
available from stock.
The availability of appropriate certification is increasingly becoming an important
factor, particularly when buying volumetric glassware. Recognising this need, the
catalogue features products which again provide you with several options relating
to glassware calibration and certification.
While the catalogue is intended to showcase the main glassware products which
are readily available, it is not all encompassing. If you are unable to locate an item
you require, please contact your local Account Manager or Customer Service
Representative and we will endeavour to source the product on your behalf.
Finally, we trust you will find the catalogue beneficial and would encourage you
to take advantage of the extensive knowledge and expertise Thermo Fisher have
available to assist you in sourcing all your glassware needs.
Volumetric Glassware
pg.05
Test, Culture &
Specialty Tubes
General Glassware
pg.21
Interchangeable Glassware
pg.57
pg.67
Please also see our Technical Information section on page 87.
Section >> Sub-Section
Containerware pg 33
Related Products
pg.83
Our Partnership Suppliers
At Thermo Fisher Scientific, we continuously strive to bring our
customers the best quality and innovative products and solutions.
We achieve this through forming partnerships with supplier
partners who specialise in market leading brands. Our success
is attributed to the significant support from our suppliers and it is
through these relationships that we relentlessly strive to extract
value for our customers.
Beakers06
Heavy Duty Beakers
08
Philips Beakers
09
Media Bottles
10
Boston Bottles
12
Erlenmeyer Flasks
14
Starter Packs
17
Plastic Coated Glassware
18
containerware
Containerware
Containerware
Beakers
Synonymous with quality and affordability, the range of LabServ glassware offers
durability at competitive prices. Buy quality, reusable glass beakers at disposable
prices. Use LabServ borosilicate glass beakers for routine measurement, mixing and
gentle heating. Chemically resistant to most solvents, acids and bases.
Laboratory Glassware Catalogue 2012/13
LabServ Low Form Beaker, Griffin, Borosilicate glass, Double Scale
6
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
OD x Height
Pack Size
Unit
LBS20201-50
50mL
10-40
5
42x60mm
Each
Pack of 12/Case of 192
LBS20201-100
100mL
20-80
10
50x70mm
Each
Pack of 12/Case of 192
LBS20201-150
150mL
20-140
10
60x80mm
Each
Pack of 12/Case of 192
LBS20201-200
* 200mL
25-175
10
66x90mm
Each
Pack of 12/Case of 144
LBS20201-250
250mL
25-200
25
70x95mm
Each
Pack of 12/Case of 144
LBS20201-300
* 300mL
25-250
25
74x105mm
Each
Pack of 12/Case of 96
LBS20201-400
400mL
50-350
25
80x110mm
Each
Pack of 12/Case of 72
LBS20201-500
500mL
50-400
25
85x120mm
Each
Pack of 6/Case of 72
LBS20201-600
600mL
100-500
50
90x125mm
Each
Pack of 6/Case of 48
LBS20201-800
800mL
100-750
50
100x135mm
Each
Pack of 6/Case of 36
LBS20201-1L
1,000mL
100-900
50
105x145mm
Each
Pack of 6/Case of 24
LBS20201-2L
2,000mL
200-1800
100
130x185mm
Each
Pack of 4/Case of 16
LBS20201-3L
3,000mL
300-2800
100
150x210mm
Each
Case of 8
LBS20201-4L
* 4,000mL
500-3500
500
161x253mm
Each
Each
LBS20201-5L
5,000mL
500-4500
500
170x270mm
Each
Case of 6
* denotes products not stocked
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
OD x Height
Pack Size
Unit
LBS20202-50
50mL
10-40
10
38x70mm
Each
Pack of 24/Case of 192
LBS20202-100
100mL
20-80
10
48x80mm
Each
Pack of 24/Case of 192
LBS20202-150
150mL
20-140
20
54x95mm
Each
Pack of 12/Case of 192
LBS20202-250
250mL
25-200
25
60x120mm
Each
Pack of 12/Case of 72
LBS20202-300
* 300mL
50-250
25
64x125mm
Each
Case of 72
LBS20202-400
400mL
50-350
25
70x130mm
Each
Pack of 12/Case of 72
LBS20202-500
* 500mL
100-400
50
75x140mm
Each
Case of 48
LBS20202-600
600mL
100-500
50
80x150mm
Each
Pack of 6/Case of 48
LBS20202-800
800mL
100-750
50
90x175mm
Each
Case of 48
LBS20202-1L
1,000mL
100-900
50
95x180mm
Each
Pack of 6/Case of 36
Containerware >> Beakers
LabServ Tall Form Beaker, Berzelius, Borosilicate glass, Double Scale
Kimble Brand KIMAX beakers provide strength and durability from top to bottom. Uniform sidewall and bottom thickness,
especially in the critical radius point of the heel area, provides excellent mechanical and thermal shock resistance. The
chemical and physical properties of KG-33 glass ensure high resistance to heat shock and chemical attack.
Kimble Low Form Beakers
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
OD x Height
Pack Size
Unit
KIM14000-10
10mL
-
-
25x34mm
Each
Each/Pack of 12/Case of 48
KIM14000-20
* 20mL
5-15
5
32x41mm
Each
Case of 48
KIM14000-30
* 30mL
5-25
10
35x53mm
Each
Case of 48
KIM14000-50
* 50mL
10-40
10
42x53mm
Each
Pack of 12/Case of 48
KIM14000-100
100mL
20-80
10
50x70mm
Each
Each/Pack of 12/Case of 48
KIM14000-150
150mL
20-140
20
57x81mm
Each
Each/Pack of 12/Case of 48
KIM14000-250
250mL
25-200
25
68x88mm
Each
Each/Pack of 12/Case of 48
KIM14000-400
400mL
50-325
25
77x106mm
Each
Each/Pack of 12/Case of 48
KIM14000-600
600mL
50-500
50
88x122mm
Each
Each/Case of 6
KIM14000-800
* 800mL
50-750
50
99x136mm
Each
Pack of 6/Case of 24
KIM14000-1000
1,000mL
100-1000
50
107x145mm
Each
Each/Pack of 6/Case of 24
KIM14000-1500
* 1,500mL
200-1400
100
120x165mm
Each
Pack of 4/Case of 16
KIM14000-2000
2,000mL
200-2000
100
130x190mm
Each
Each/Pack of 4/Case of 8
KIM14000-4000
* 4,000mL
500-3500
250
161x250mm
Each
Case of 6
7
Containerware
Containerware
Heavy Duty Beakers
KIMAX beakers with thick uniform walls throughout and extra wall thickness
built into the evenly tooled top rim. Spout is designed for optimum performance.
Heavy construction is intended to prolong life with harder than normal usage (i.e.
mechanical shock). Not recommended for use on hot plates where significant
thermal gradients exist due to lack of agitation of contents or absence of a
temperature control. All sizes have a durable matte finish marking area and a white
graduated scale. Designed from ASTM Specification E960, Type II requirements.
Laboratory Glassware Catalogue 2012/13
Kimble KIMAX Beaker, Spouted, Heavy Duty, Low Form, Double Capacity White Colour Scale
8
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
OD x Height
Pack Size
Unit
KIM14005-250
250mL
25-200
25
67x92mm
Each
Case of 48
KIM14005-400
400mL
25-325
25
77x114mm
Each
Case of 48
KIM14005-600
600mL
50-500
50
87x122mm
Each
Case of 36
KIM14005-1000 1,000mL
100-1000
50
107x152mm
Each
Case of 24
KIM14005-2000 2,000mL
200-1800
200
130x190mm
Each
Case of 8
KIM14005-4000 4,000mL
500-3500
500
161x252mm
Each
Case of 4
* denotes products not stocked
Schott Duran Philips Beakers, With Spout
Item Code
Capacity
Diameter
Height
Pack Size
Unit
SCH2114129
* 150mL
59mm
87mm
10 pcs
Each
SCH2114136
* 250mL
68mm
105mm
10 pcs
Each
SCH2114144
* 500mL
86mm
142mm
10 pcs
Each
Containerware >> Heavy Duty & Philips Beakers
Philips Beakers
9
Containerware
Containerware
Media Bottles
• Enhanced graduations
• Permanent white enamel marking spot
• GL 45 screw thread
• Clear (natural), drip-free, replaceable polypropylene pour ring
• Linerless
• Autoclavable (to 140°C)
• Polypropylene cap
Laboratory Glassware Catalogue 2012/13
Fisherbrand Graduated Laboratory Bottles, with Polypropylene Screw Cap and Pouring Ring
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
Approx. OD x Height
Pack Size
(Unassembled)
Unit
FSBFB33144
100mL
20-80
10
56x100mm
Each
Case of 10
FSBFB33145
250mL
50-200
25
70x138mm
Each
Case of 10
FSBFB33146
500mL
100-400
50
86x176mm
Each
Case of 10
FSBFB33147
1,000mL
100-900
50
101x225mm
Each
Case of 10
FSBFB33148
2,000mL
400-1800
100
136x262mm
Each
Each
FSBFB33180
5,000mL
1000-4000
250
186x355mm
Each
Each
FSBFB33181
10,000mL
2000-8000
500
234x435mm
Each
Each
Fisherbrand Screw Caps and Pouring Rings
Item Code
10
Description
GL Thread
Colour
Pack Size
Unit
FSBGLBBC
Screw cap PP
45
Blue
Each
Case of 10
FSBGLBBR
Pouring ring PP
45
Clear
Each
Case of 10
FSBGLBRC
Screw cap PBTP with liner 45
Red
Each
Case of 10
* denotes products not stocked
Item Code
Capacity
GL Thread
Width (mm)
Height (mm)
Pack Size
Unit
SCH21801175
50mL
32
46
87
Each
Case of 10
SCH21801245
100mL
45
56
100
Each
Case of 10
SCH21801365
250mL
45
70
138
Each
Case of 10
SCH21801545
1,000mL
45
101
225
Each
Case of 10
SCH21801635
2,000mL
45
136
260
Each
Case of 10
Schott Duran Screw Caps and Pouring Rings
Item Code
Description
GL Thread
Colour
Pack Size
Unit
SCH2923928
Screw cap PP
45
Blue
Each
Case of 10
SCH2924228
Pouring ring PP
45
Blue
Each
Case of 10
Containerware >> Media Bottles
Schott Duran Graduated Laboratory Bottles, with Polypropylene Screw Cap and Pouring Ring
The RAY-SORB® process provides a shield to protect light
sensitive products. Less than 1% transmission below 400 nm
and reduced (5%) from 400-600 nm as compared to untreated,
clear, borosilicate glass. Bottles are provided with enhanced
graduation scale; cap and drip-free pour ring included.
Kimble Graduated Laboratory Bottles, RAY-SORB, with Polypropylene Scew Cap
Item Code
KIM14399-500
Capacity
* 500mL
Graduations
Range (mL)
Graduations
Interval (mL)
OD x Height*
Pack Size
Unit
100-400
50
86x176mm
Each
Each
KIM14399-1000
* 1,000mL
100-900
50
101x225mm
Each
Each
KIM14399-2000
* 2,000mL
400-1800
100
136x262mm
Each
Each
KIM14399-5000
* 5,000mL
KIM14399-10000 * 10,000mL
1000-4500
250
186x355mm
Each
Each
2000-9000
500
234x435mm
Each
Each
* Approximate OD x Height Unassembled
11
Containerware
Containerware
Boston Bottles
Cospak Bottles, Clear and Amber, Round, Caps Sold Separately
Item Code
COSH0529
Type
* Clear bottle
Capacity
Neck Finish
Height
Diameter
Pack Size
Unit
50mL
24mm
86mm
38mm
220pcs
Each
COSH0936
* Clear bottle
100mL
24mm
107mm
47mm
56pcs
Each
COSH1631
* Clear bottle
200mL
24mm
136mm
59mm
39pcs
Each
COSH721
* Amber bottle
100mL
24mm
109.4mm
45.9mm
122pcs
Each
COSH720
* Amber bottle
200mL
24mm
135.9mm
57mm
82pcs
Each
COSH725
Amber bottle
500mL
28mm
183.7mm
75.4mm
25pcs
Each
COSH4701
Amber bottle
1,000mL
33mm
206mm
96mm
12pcs
Each
COS2450
* White wadded cap
24mm
Each
Each
COS2855
White wadded cap
28mm
Each
Each
COS3331
* White wadded cap
33mm
Each
Each
Laboratory Glassware Catalogue 2012/13
Available in Australia Only
12
* denotes products not stocked
Containerware >> Boston Bottles
• Boston round amber Type III glass bottle
• Caps for 125mL and 250mL sizes are ultrasonically bonded with a .125”
Teflon®-lined silicone liner
• Caps for 500mL and 1000mL sizes are equipped with a friction-fit Teflon® liner
which is easily replaced if necessary
• Polypropylene closure. Excellent for water sampling. Recommended for UV light
sensitive samples
• I-CHEM Certified® 200 and 300 Series bottles are guaranteed to meet the
EPA’s Performance Based Specifications for Metals (Group 1) and SemiVolatiles/Pesticides/PCBs (Group 2) analysis
Kimble Chase Boston Round Bottles
Item Code
Type
Capacity
Group
Closure
Pack Size
Unit
NALICHEM249-0250
* Round amber bottle
250mL
1&2
24-414
Each
Case of 12
NALICHEM249-0500
* Round amber bottle
500mL
1&2
28-400
Each
Case of 12
NALICHEM249-1000
NALICHEM241-0250
Round amber bottle
* Tall wide mouth amber bottle
1,000mL
1&2
33-430
Each
Case of 12
250mL
1&2
45-400
Each
Case of 12
13
Containerware
Containerware
Erlenmeyer Flasks
Synonymous with quality and affordability, the range of LabServ glassware offers
durability at competitive prices. Buy quality, reusable glass flasks at disposable
prices. Use LabServ borosilicate glass flasks for routine measurement, mixing and
gentle heating. Chemically resistant to most solvents, acids and bases.
LabServ Erlenmeyer Flasks, Narrow Neck, Graduated
Item Code
Laboratory Glassware Catalogue 2012/13
LBS20401-02-50
Capacity
* 50mL
Neck OD
Flask OD
Height
Pack Size
Unit
26mm
54mm
80mm
Each
Case of 192
LBS20401-02-100
100mL
32mm
66mm
106mm
Each
Case of 192
LBS20401-02-150
* 150mL
32mm
75mm
124mm
Each
Case of 144
LBS20401-02-250
250mL
34mm
85mm
140mm
Each
Case of 72
LBS20401-02-300
* 300mL
34mm
90mm
162mm
Each
Case of 48
LBS20401-02-500
500mL
38mm
103mm
184mm
Each
Case of 48
LBS20401-02-1L
* 1,000mL
45mm
131mm
214mm
Each
Case of 24
LBS20401-02-2L
2,000mL
50mm
166mm
280mm
Each
Case of 12
LBS20401-02-3L
3,000mL
50mm
187mm
310mm
Each
Case of 6
LBS20401-02-5L
5,000mL
50mm
220mm
365mm
Each
Case of 6
LabServ Erlenmeyer Flasks, Wide Neck, Graduated
14
Item Code
Capacity
Neck OD
Flask OD
Height
Pack Size
Unit
LBS20401-04-250
250mL
34mm
85mm
140mm
Each
Case of 72
LBS20401-04-500
* 500mL
34mm
105mm
175mm
Each
Case of 48
LBS20401-04-1L
* 1,000mL
42mm
131mm
220mm
Each
Case of 24
* denotes products not stocked
Item Code
Capacity
Flask OD
Pack Size
Unit
GLS075.202.01
* 50mL
51mm
10pcs
Each
GLS075.202.02
* 100mL
64mm
10pcs
Each
GLS075.202.03
* 150mL
74mm
10pcs
Each
GLS075.202.04
* 250mL
85mm
10pcs
Each
GLS075.202.05
* 500mL
105mm
10pcs
Each
GLS075.202.06
* 1,000mL
131mm
10pcs
Each
Containerware >> Erlenmeyer Flasks
Glassco Erlenmeyer Flasks, with PTFE Lined Screw Cap, Graduated
Kimble brand KIMAX erlenmeyer flasks, reinforced beaded top with
capacity scale. All flasks have durable white ceramic enamel scales to
indicate approximate volumes at various levels, useful in measuring
and mixing solutions where a high degree of accuracy is unnecessary.
Designed from ASTM Specification E1404, Type I, Class 1 requirements.
Kimble Erlenmeyer Flasks, Narrow Neck
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
Widest
Height (mm)
Diameter (mm)
Pack Size
Unit
KIM26500-25
* 25mL
10-25
5
39
65
Each
Case of 48
KIM26500-125
* 125mL
50-125
25
66
108
Each
Case of 48
KIM26500-250
250mL
KIM26500-500
* 500mL
50-225
25
82
130
Each
Case of 48
100-500
50
102
174
Each
Case of 36
KIM26500-1000
* 1,000mL
250-1000
50
128
213
Each
Case of 24
KIM26500-2000
* 2,000mL
600-2000
100
161
275
Each
Case of 8
15
Containerware
Containerware
Kimble Erlenmeyer Flasks, Wide Neck
Item Code
Capacity
Graduations
Range (mL)
Graduations
Interval (mL)
Widest
Height (mm)
Diameter (mm)
Pack Size
Unit
KIM26650-125
125mL
50-125
25
66
Each
Case of 48
KIM26650-250
250mL
KIM26650-500
* 500mL
108
50-22
25
77
130
Each
Case of 48
100-500
50
97
172
Each
Case of 36
* 1,000mL
250-1000
50
122
216
Each
Case of 24
* 2,000mL
600-2000
200
161
265
Each
Case of 8
Laboratory Glassware Catalogue 2012/13
KIM26650-1000
KIM26650-2000
Kimble Erlenmeyer Filtering Flasks, with Capacity Scale and Side Tubulation
Item Code
KIM27060-500
16
Capacity
* 500mL
Graduations
Interval
Subdivision
Widest
Height mm Pack Size
Diameter (mm)
Unit
150-500
50
104
Case of 18
190
Each
KIM27060-1000
1,000mL
300-1000
50
135
238
Each
Case of 12
KIM27060-2000
* 2,000mL
600-2000
100
168
300
Each
Each
* denotes products not stocked
Save money and space by getting a variety of sizes without having to order case
quantities of each size. They provide precisely what you need, when you need it,
without the extras that could slow you down.
Kimble Lab Starter Packs, One of Each Size Included
Item Code
Type
Sizes (mL)
Pack Size
Unit
KIM14080-01
* Beakers
50, 100, 250, 600, 1000
5pcs
Each
KIM14085-01
* Heavy duty beakers
250, 400, 600, 1000
4pcs
Each
KIM26520-1
* Erlenmeyer flasks
10, 25, 50, 100, 250
5pcs
Each
KIM20024-01
* Cylinders
20, 125, 250, 500, 1000
5pcs
Each
Containerware >> Erlenmeyer Flasks & Starter Packs
Starter Packs
17
Containerware
Containerware
Plastic Coated Glassware
KimCote® Plastic-Coated Glassware for an Added Measure of Safety.
Plastic coating on glassware Prevents & contains spills in broken glassware
Ultra-clear coating Improved sample viewing
Non-slip coating surface Easier handling in the lab
Steam autoclavable Easy to clean and sterilise
Chemically resistant Use with hazardous chemicals
Odour free coating No noxious fumes present
Laboratory Glassware Catalogue 2012/13
KimCote® protective glassware coating goes beyond traditional coatings. Should a break occur, KimCote® will
reduce the hazards of shattered glass and leakage of toxic or corrosive chemicals. It is ultra-clear, extremely
durable, autoclavable and resistant to many common laboratory chemicals. KimCote®’s unique texture also
provides a non-slip handling surface, wet or dry.
18
Kimble Plastic Coated Media Bottles
Item Code
Capacity
Graduations
Range (mL)
Intervals (mL) Approx. OD
Approx. Height Pack Size
Unit
KIMKC14395-100
* 100mL
20-80
10
56mm
100mm
4pcs
Each
KIMKC14395-250
* 250mL
50-200
25
70mm
138mm
4pcs
Each
KIMKC14395-500
* 500mL
100-400
50
86mm
176mm
4pcs
Each
KIMKC14395-1000
* 1,000mL
100-900
50
101mm
225mm
4pcs
Each
KIMKC14395-2000
* 2,000mL
400-1800
100
136mm
262mm
4pcs
Each
KIMKC14395-5000
* 5,000mL
1000-4000
250
186mm
355mm
Each
Each
KIMKC14395-10000
* 10,000mL
2000-8000
500
234mm
435mm
Each
Each
* denotes products not stocked
Item Code
Capacity
Graduations
Range (mL)
Subdivisions
(mL)
±Tol (mL)
Approx. Height Pack Size
Unit
KIMKC20028W-100
* 100mL
2-100
1
0.4
255mm
Each
Each
KIMKC20028W-250
* 250mL
10-250
2
0.8
330mm
Each
Each
KIMKC20028W-500
* 500mL
25-500
5
1.3
375mm
Each
Each
KIMKC20028W-1000
* 1,000mL
50-1000
10
2.5
460mm
Each
Each
KIMKC20028W-2000
* 2,000mL
100-2000
20
6
520mm
Each
Each
Containerware >> Plastic Coated Glassware
Kimble Plastic Coated Cylinders, Graduated, with Bumper
Kimble Plastic Coated Erlenmeyer Flasks, with Screw Cap, Wide Mouth
Item Code
Capacity
Approx. Widest
Diameter
Approx. Height
with Cap
GPI Thread Finish Pack Size
Unit
KIMKC26720-250
* 250mL
81mm
130mm
GL45
6pcs
Each
KIMKC26720-500
* 500mL
102mm
165mm
GL45
6pcs
Each
KIMKC26720-1000
* 1,000mL
128mm
205mm
GL45
4pcs
Each
KIMKC26720-2000
* 2,000mL
161mm
265mm
GL45
2pcs
Each
19
Containerware
Containerware
Kimble Plastic Coated Volumetric Flasks, with Glass Stopper
Item Code
Capacity
±Tol (mL)
Stopper Size
Approx. Height with
Pack Size
Stopper
Unit
* 100mL
0.08
13
180mm
12pcs
Each
KIMKC28014-250
* 250mL
0.12
16
250mm
12pcs
Each
KIMKC28014-500
* 500mL
0.2
19
287mm
12pcs
Each
KIMKC28014-1000
* 1,000mL
0.3
22
338mm
4pcs
Each
KIMKC28014-2000
* 2,000mL
0.5
27
400mm
2pcs
Each
Laboratory Glassware Catalogue 2012/13
KIMKC28014-100
Kimble Plastic Coated Filter Flasks, Heavy-wall, 6mm Side Arm
Item Code
20
Capacity
Stopper Size
Pack Size
Unit
KON953760-0122
* 125mL
5
Each
Each
KON953760-1002
* 1,000mL
8
Each
Each
KON953760-2002
* 2,000mL
8
Each
Each
KON953760-4002
* 4,000mL
8
Each
Each
* denotes products not stocked
Volumetric Flasks
22
Measuring Cylinders
25
Mixing Cylinders
27
Burettes28
Automatic Burettes
29
Pipettes30
volumetric glassware
Volumetric Glassware
Volumetric Glassware
Volumetric Flasks
Synonymous with quality and affordability, the range of LabServ glassware offers
durability at competitive prices. Buy quality, reusable glass flasks at disposable
prices. Use LabServ borosilicate glass flasks for routine measurement, mixing and
gentle heating. Chemically resistant to most solvents, acids and bases.
Laboratory Glassware Catalogue 2012/13
LabServ Volumetric Flasks, Polyethylene Stopper, Class A
22
Item Code
Capacity
Accuracy Limits
±mL
Stopper Size
OD x Height
Pack Size
Unit
LBS40620-25
25mL
0.03
10/13
37x110mm
Each
Case 120
LBS40620-50
50mL
0.05
10/13
49x140mm
Each
Case of 50
LBS40620-100
100mL
0.1
12.5/14
60x170mm
Each
Case of 50
LBS40620-250
250mL
0.15
14.5/15
80x220mm
Each
Case of 36
LBS40620-500
500mL
0.25
18.8/17
100x265mm
Each
Case of 24
LBS40620-1000
1,000mL
0.4
18.8/17
127x315mm
Each
Case of 15
LBS40620-2000
2,000mL
0.6
24/20
160x375mm
Each
Case of 12
LBS40620-5000
5,000mL
1.2
34.5/35
221x470mm
Each
Case of 6
* denotes products not stocked
Glassco Volumetric Flasks, Polypropylene Stopper, Class A, as per DIN ISO 1042 Standards, Conformity Batch Certified
Item Code
Capacity
Tolerance Limits ±mL Stopper Size
Pack Size
Unit
GLS130.202.01
5mL
0.025
10/19
Each
Case of 2
GLS130.202.02
10mL
0.025
10/19
Each
Case of 2
GLS130.202.02A
20mL
0.04
10/19
Each
Case of 2
GLS130.202.03
25mL
0.04
10/19
Each
Case of 2
GLS130.202.04
50mL
0.06
12/21
Each
Case of 2
GLS130.202.05
100mL
0.1
14/23
Each
Case of 2
GLS130.202.06
200mL
0.15
14/23
Each
Case of 2
GLS130.202.07
250mL
0.15
14/23
Each
Case of 2
GLS130.202.08
500mL
0.25
19/26
Each
Case of 2
GLS130.202.09
1,000mL
0.4
24/29
Each
Case of 2
GLS130.202.10
2,000mL
0.6
29/32
Each
Each
Section >> General
Glassware Sub-Section
>> Volumetric Flasks
Glassco volumetric flasks are made from ASTM E-438 Type 1 Class A heat resistant
BORO 3.3 glass that meets ISO 1042 standards. The calibration is done on
automatic computer controlled machines and the flasks are calibrated to contain
according to the ISO tolerance standards. These are supplied with polypropylene
stoppers in both amber and clear glass. All Class A flasks are printed in blue colour.
The meniscus mark is diamond ground for longer persistence and better accuracy.
23
Laboratory Glassware Catalogue 2012/13
Volumetric Glassware
Volumetric Glassware
24
Glassco Volumetric Flasks, Amber, Polypropylene Stopper, Class A, as per DIN ISO 1042 Standards, Conformity
Batch Certified
Item Code
GLS130.202.01A
Capacity
* 5mL
Tolerance Limits ±mL Stopper Size
Pack Size
Unit
0.025
Each
Case of 2
10/19
GLS130.202.02AB
* 10mL
0.025
10/19
Each
Case of 2
GLS130.202.04A
* 25mL
0.04
10/19
Each
Case of 2
GLS130.202.05A
* 50mL
0.06
12/21
Each
Case of 2
GLS130.202.06A
* 100mL
0.1
14/23
Each
Case of 2
GLS130.202.07A
* 200mL
0.15
14/23
Each
Case of 2
GLS130.202.08A
* 250mL
0.15
14/23
Each
Case of 2
GLS130.202.09A
* 500mL
0.25
19/26
Each
Case of 2
GLS130.202.10A
* 1,000mL
0.4
24/29
Each
Case of 2
GLS130.202.11A
* 2,000mL
0.6
29/32
Each
Case of 2
Kimble Volumetric Flasks, RAY-SORB, with PTFE Stopper
Item Code
Capacity
Tolerance Limits
±mL
Stopper Size
Approx. Height
with Stopper
Pack Size
Unit
KIM92822F-5
* 5mL
0.08
13
94mm
6pcs
Each
KIM92822F-10
* 10mL
0.08
13
97mm
6pcs
Each
KIM92822F-20
* 20mL
0.08
13
127mm
6pcs
Each
KIM92822F-25
* 25mL
0.08
13
127mm
6pcs
Each
KIM92822F-50
* 50mL
0.08
13
147mm
6pcs
Each
KIM92822F-100
* 100mL
0.1
16
175mm
6pcs
Each
KIM92822F-200
* 200mL
0.2
19
217mm
6pcs
Each
KIM92822F-250
* 250mL
0.2
19
269mm
6pcs
Each
KIM92822F-500
* 500mL
0.2
19
300mm
6pcs
Each
KIM92822F-1000
* 1,000mL
0.3
22
328mm
Each
Each
KIM92822F-2000
* 2,000mL
0.5
27
392mm
Each
Each
* denotes products not stocked
Glassco measuring cylinders are made from ASTM E-438 Type 1 Class A BORO 3.3
glass that meets ISO 4788 standards. The calibration is performed on automatic
computer controlled machines, and cylinders are calibrated to contain according to
the ISO tolerance standards. All Class A cylinders are printed in blue colour.
Glassco Measuring Cylinders, Hexagonal Base, Class A, as per DIN EN ISO 4788 & USP Standards, with Lot Certificate
Item Code
Capacity
Subdivision
Tolerance ±mL
Pack Size
Unit
GLS139.202.01A
10mL
0.2
0.1
Each
Case of 2
GLS139.202.02A
25mL
0.5
0.25
Each
Case of 2
GLS139.202.03A
50mL
1
0.5
Each
Case of 2
GLS139.202.04A
100mL
1
0.5
Each
Case of 2
GLS139.202.05A
250mL
2
1
Each
Case of 2
GLS139.202.06A
500mL
5
2.5
Each
Case of 2
GLS139.202.07A
1,000mL
10
5
Each
Each
GLS139.202.08A
2,000mL
20
10
Each
Each
Glassco Measuring Cylinders, Hexagonal Base, Class A, as per DIN EN ISO 4788 & USP standards, with Individual
Work Certificate, Serially Numbered
Item Code
Capacity
Subdivision
Tolerance ±mL
Pack Size
Section >> Glassware Volumetric
Sub-Section >> Volumetric Flasks & Measuring Cylinders
Measuring Cylinders
Unit
GLS139.223.01A
* 10mL
0.2
0.1
Each
Case of 2
GLS139.223.02A
* 25mL
0.5
0.25
Each
Case of 2
GLS139.223.03A
* 50mL
1
0.5
Each
Case of 2
GLS139.223.04A
* 100mL
1
0.5
Each
Case of 2
GLS139.223.05A
* 250mL
2
1
Each
Case of 2
GLS139.223.06A
* 500mL
5
2.5
Each
Case of 2
GLS139.223.07A
* 1,000mL
10
5
Each
Each
GLS139.223.08A
* 2,000mL
20
10
Each
Each
25
Laboratory Glassware Catalogue 2012/13
Volumetric Glassware
Volumetric Glassware
26
Glassco Measuring Cylinders, Hexagonal Base, Class A, according to USP and ASTM E1272 Standards, Graduated
To Deliver (TD), with Individual Work Certificate, Serially Numbered
Item Code
GLS139.220.01A
Capacity
* 10mL
Subdivision
Tolerance ±mL
Pack Size
Unit
0.2
0.1
Each
Case of 2
GLS139.220.02A
* 25mL
0.5
0.15
Each
Case of 2
GLS139.220.03A
* 50mL
1
0.25
Each
Case of 2
GLS139.220.04A
* 100mL
1
0.5
Each
Case of 2
GLS139.220.05A
* 250mL
2
1
Each
Case of 2
GLS139.220.06A
* 500mL
5
1.5
Each
Case of 2
GLS139.220.07A
* 1,000mL
10
3
Each
Each
GLS139.220.08A
* 2,000mL
20
6
Each
Each
Glassco Measuring Cylinders, Detachable Polypropylene Base, Protection Collar, Class B, as per DIN EN ISO 4788
Standards
Item Code
Capacity
Subdivision
Tolerance ±mL
Pack Size
Unit
GLS137.202.02
10mL
0.2
0.02
Each
Case of 10
GLS137.202.03
25mL
0.5
0.05
Each
Case of 10
GLS137.202.04
50mL
1
1
Each
Case of 10
GLS137.202.05
100mL
1
1
Each
Case of 10
GLS137.202.06
250mL
2
2
Each
Case of 10
* denotes products not stocked
Glassco Mixing Cylinders, Polypropylene Stopper, Round Base, Class A, as per DIN EN ISO 4788 Standards
Item Code
GLS141.202.02
Capacity
* 10mL
Subdivision
Tolerance ±mL
Pack Size
Unit
0.2
0.1
Each
Case of 2
GLS141.202.03
25mL
0.5
0.25
Each
Case of 2
GLS141.202.04
50mL
1
0.5
Each
Case of 2
GLS141.202.05
100mL
1
0.5
Each
Case of 2
GLS141.202.06
250mL
2
1
Each
Case of 2
GLS141.202.07
500mL
5
2.5
Each
Case of 2
GLS141.202.08
1,000mL
10
5
Each
Each
GLS141.202.09
* 2,000mL
20
10
Each
Each
Section >> Glassware Volumetric
Sub-Section >> Measuring & Mixing Cylinders
Mixing Cylinders
27
Volumetric Glassware
Volumetric Glassware
Burettes
Glassco burettes are manufactured from ASTM E-438 Type 1 Class A BORO 3.3
heat resistant glass which meets ISO 385 and USP standards. Each and every piece
is calibrated to deliver. All Class A burettes are manufactured from precision bore
tubing for accuracy. The burettes are calibrated on computer controlled machines to
give the most accurate results and then are rechecked at the quality control centre.
Class A burettes come with either conformity batch or individual work certification.
All Class A burettes are printed in blue colour and have a waiting time of 30
seconds; Class B burettes are printed in amber colour and have no waiting time.
Laboratory Glassware Catalogue 2012/13
Glassco Straight Bore Burettes, PTFE Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate
28
Item Code
Capacity
Subdivision
Tolerance ±mL
Pack Size
Unit
GLS114.202.04A
10mL
0.05
0.02
Each
Each
GLS114.202.05A
25mL
0.1
0.03
Each
Each
GLS114.202.06A
50mL
0.1
0.05
Each
Each
GLS114.202.07A
* 100mL
Each
Each
Glassco Straight Bore Burettes, Glass Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate
Item Code
GLS110.202.01A
Capacity
* 10mL
Subdivision
Tolerance ±mL
Pack Size
Unit
0.05
0.02
Each
Each
GLS110.202.02A
* 25mL
0.1
0.03
Each
Each
GLS110.202.03A
* 50mL
0.1
0.05
Each
Each
GLS110.202.04A
* 100mL
Each
Each
* denotes products not stocked
Item Code
GLS113.202.01
Capacity
* 10mL
Subdivision
Tolerance ±mL
Pack Size
Unit
0.05
0.02
Each
Each
GLS113.202.02
* 25mL
0.1
0.03
Each
Each
GLS113.202.03
* 50mL
0.1
0.05
Each
Each
GLS113.202.04
* 100mL
Each
Each
Automatic Burettes
Glassco burettes are manufactured from ASTM E-438 Type 1 Class A BORO 3.3
heat resistant glass which meets ISO 385 and USP standards. Each and every piece
is calibrated to deliver. All Class A burettes are manufactured from precision bore
tubing to maintain accuracy. These burettes come with either PTFE needle valve
stopcocks or intermediate PTFE key stopcocks. Burettes feature printing in blue
colour for better visibility.
Section >> Glassware Volumetric
Sub-Section >> Burettes
Glassco Burettes, Screw Type PTFE Needle Valve Stopcock, as per DIN ISO 385 and USP standards, with Lot Certificate
Glassco Automatic Burettes, with Intermediate Stopcock, PTFE Key and Needle Valve Stopcock, Schellbach
Stripe, as per DIN ISO 385 and USP Standards, Class AS, Conformity Certified
Item Code
Capacity
Subdivision
Tolerance ±mL
Bottle Capacity
Pack Size
Unit
GLS118.240.01
* 10mL
0.05
0.02
500mL
Each
Each
GLS118.240.02
* 25mL
0.1
0.03
2,000mL
Each
Each
GLS118.240.03
* 50mL
0.1
0.05
2,000mL
Each
Each
29
Volumetric Glassware
Volumetric Glassware
Pipettes
Glassco volumetric pipettes are manufactured in compliance with DIN ISO 648
standards. These pipettes are calibrated to deliver. All volumetric pipettes are
calibrated by automatic machine, and the final quality check is performed at the
quality control centre. The volumetric pipettes are printed in amber colour which is
fused into the glass.
Glassco Volumetric Pipettes, One Mark, Class A, as per DIN ISO 648 Standards, with Batch Certificate
Laboratory Glassware Catalogue 2012/13
Item Code
30
Capacity
Colour Code
Tolerance ±mL
Pack Size
Unit
GLS123.202.01
1mL
Blue
0.007
Each
Case of 5
GLS123.202.02
2mL
Orange
0.01
Each
Case of 5
GLS123.202.03
5mL
White
0.015
Each
Case of 5
GLS123.202.04
10mL
Red
0.02
Each
Case of 5
GLS123.202.05
20mL
Yellow
0.03
Each
Case of 5
GLS123.202.06
25mL
Blue
0.03
Each
Case of 5
GLS123.202.07
50mL
Red
0.05
Each
Case of 5
GLS123.202.08
100mL
Yellow
0.08
Each
Case of 5
* denotes products not stocked
Section >> Glassware Volumetric
Sub-Section >> Pipettes
Glassco graduated pipettes are manufactured to meet ISO 835 standards. These
pipettes are calibrated to deliver. All graduated pipettes are calibrated by automatic
machine, and the final quality check is performed at the quality control centre. The
graduated pipettes are printed in amber colour which fuses into the glass. All Class
A pipettes have a waiting time of 5 seconds.
Glassco Graduated Pipettes, Class AS, as per DIN ISO 648 Standars, with Batch Certificate
Item Code
Capacity
Colour Code
Tolerance ±mL
Pack Size
Unit
GLS125.202.01
1mL
Yellow
0.007
Each
Case of 5
GLS125.202.02
* 2mL
GLS125.202.03
5mL
Black
0.01
Each
Case of 5
Red
0.03
Each
Case of 5
GLS125.202.04
10mL
Orange
0.05
Each
Case of 5
GLS125.202.06
25mL
White
0.1
Each
Case of 5
Kimble Chase pasteur pipettes are made of disposable soda lime glass. Available
sterile and non-sterile, plugged and non-plugged. For one time use in the transfer of
small volumes.
Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass
Item Code
Overall Length Type
Tip Length
Body Length
OD
Pack Size
Unit
CSEJ5000
5.75 inch
Non-plugged
2.25 inch
3.5 inch
7mm
1000pcs
Each
CSEJ5000P
5.75 inch
Plugged
2.25 inch
3.5 inch
7mm
1000pcs
Each
CSEJ9000
9 inch
Non-plugged
5 inch
4 inch
7mm
1000pcs
Each
CSE63B.93P
9 inch
Plugged
5 inch
4 inch
7mm
1000pcs
Each
Available in Australia Only
31
Volumetric Glassware
Volumetric Glassware
Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass
Item Code
Overall Length Type
Tip Length
Body Length
OD
Pack Size
Unit
KIM63A54
145mm
Non-plugged
57mm
89mm
7mm
250pcs
Each/Case of 4
KIM63A54P
145mm
Plugged
57mm
89mm
7mm
250pcs
Each/Case of 4
230mm
Non-plugged
127mm
102mm
7mm
250pcs
Each/Case of 4
Plugged
127mm
102mm
7mm
250pcs
Case of 4
KIM63B93
KIM63B93P
* 230mm
Available in New Zealand Only
Kimble Chase Pasteur Pipettes, Sterile, Disposable, Soda Lime Glass
Laboratory Glassware Catalogue 2012/13
Item Code
32
Overall Length Type
Tip Length
Body Length
OD
Pack Size
Unit
KIM63A55
* 5.75 inch
Non-plugged
2.25 inch
3.5 inch
7mm
250pcs
Each
KIM63A55P
* 5.75 inch
Plugged
2.25 inch
3.5 inch
7mm
250pcs
Each
KIM63B95
* 9 inch
Non-plugged
5 inch
4 inch
7mm
250pcs
Each
KIM63B95P
* 9 inch
Plugged
5 inch
4 inch
7mm
250pcs
Each
* denotes products not stocked
BOD Bottles34
Gas Washing Bottles35
Counting Chambers36
Weighing Scoops37
Crystallising Dishes37
Funnels39
Desiccators40
Scintillation Vials41
Trident Vials42
Pathological Vials43
Petri Dishes44
Watch Glasses45
Separating Funnels46
Condensers47
Filtration Glassware49
Jars52
Babcock Bottles53
Mojonnier Tubes53
Miscellaneous54
Microscopy55
general glassware
General Glassware
General Glassware
BOD Bottles
Glassco BOD bottles are manufactured from ASTM E-438 Type 1 Class A BORO 3.3
glass.
Glassco BOD Bottles, with Glass Stopper
Item Code
Capacity
Diameter
Height
Pack Size
Unit
* 125mL
55mm
120mm
Each
Case of 2
GLS284.202.02
* 300mL
70mm
150mm
Each
Case of 2
Capacity
Type
Stopper
Pack Size
Unit
300mL
Numbered 01-24
Glass robotic stopper
Each
Case of 24
* 300mL
Numbered 25-48
Glass robotic stopper
Each
Case of 24
Laboratory Glassware Catalogue 2012/13
GLS284.202.01
Wheaton BOD Bottles
Item Code
WHE227497
WHE227497-02
Available in New Zealand Only. Other sizes available, please contact us for further information
34
* denotes products not stocked
Bottles
Item Code
GLS286.202.01
Capacity
* 125mL
Pack Size
Unit
Each
Each
GLS286.202.02
* 250mL
Each
Each
GLS286.202.03
* 500mL
Each
Each
Pack Size
Unit
Heads
Item Code
Capacity
GLS285.202.01
* 125mL
Each
Each
GLS285.202.02
* 250mL
Each
Each
GLS285.202.03
* 500mL
Each
Each
General Glassware >> BOD Bottles & Gas Washing Bottles
Gas Washing Bottles
35
General Glassware
General Glassware
Counting Chambers
Boeco Haemacytometer, Neubauer Improved Bright Line, Includes Two Cover Glasses
Item Code
Type
Pack Size
Unit
BOKBOE14
Double ruled
Each
Each
Laboratory Glassware Catalogue 2012/13
Available in Australia Only.
Schott Duran Haemacytometers, Neubauer Improved, Double Net Ruling, Includes Two Cover Glasses
Item Code
Type
Depth
Pack Size
Unit
SCH8100204
* Bright lined
0.1mm
Each
Each
SCH8100104
* Standard
0.1mm
Each
Each
Web Haemacytometer and Coverslips
Item Code
Type
Depth
WEBAC1000
Standard
0.1mm
WEBZ5000
Coverslips
Heamacytometer
Size
22x25mm
Pack Size
Unit
Each
Each
10pcs
Each
Available in New Zealand Only.
36
* denotes products not stocked
Glassco Weighing Scoops, with Open Tubular Arm
Item Code
Capacity
Pack Size
Unit
GLS245.202.01
3mL
Each
Case of 10
GLS245.202.02
6mL
Each
Case of 10
GLS245.202.03
10mL
Each
Case of 10
Crystallising Dishes
Manufactured from ASTM E-438 Type 1 Class A BORO 3.3 glass. These dishes
conform to DIN and USP standards. The dishes are printed in white colour and
feature a white marking area for use with pencil.
Glassco Crystallising Dishes, without Spout
Item Code
Diameter
Height
Pack Size
Unit
GLS246.202.01
* 40mm
25mm
Each
Case of 10
GLS246.202.02
* 50mm
30mm
Each
Case of 10
GLS246.202.03
* 60mm
35mm
Each
Case of 10
GLS246.202.04
* 70mm
40mm
Each
Case of 10
GLS246.202.05
* 80mm
45mm
Each
Case of 10
GLS246.202.06
* 95mm
55mm
Each
Case of 10
General Glassware >> Counting Chambers, Weighing Scoops & Crystalising Dishes
Weighing Scoops
37
Glassco Crystallising Dishes, with Spout
Item Code
Diameter
Height
Pack Size
Unit
GLS246.202.01S
* 40mm
25mm
Each
Case of 10
GLS246.202.02S
* 50mm
30mm
Each
Case of 10
GLS246.202.03S
* 60mm
35mm
Each
Case of 10
GLS246.202.04S
* 70mm
40mm
Each
Case of 10
GLS246.202.05S
* 80mm
45mm
Each
Case of 10
GLS246.202.06S
* 95mm
55mm
Each
Case of 10
Laboratory Glassware Catalogue 2012/13
General Glassware
General Glassware
38
* denotes products not stocked
General Glassware >> Crystalising Dishers & Funnels
Funnels
Glassco Funnels, with Short Stem, Borosilicate Glass
Item Code
Diameter
Pack Size
Unit
GLS238.202.01
25mm
Each
Case of 10
GLS238.202.04
40mm
Each
Case of 10
GLS238.202.05
50mm
Each
Case of 10
GLS238.202.07
65mm
Each
Case of 10
GLS238.202.08
70mm
Each
Case of 10
GLS238.202.09
75mm
Each
Case of 10
GLS238.202.10
80mm
Each
Case of 10
GLS238.202.11
100mm
Each
Case of 10
GLS238.202.12
* 125mm
Each
Case of 10
GLS238.202.13
150mm
Each
Case of 10
Glassco Powder Funnels, Borosilicate Glass
Item Code
Diameter
Cone Size
Pack Size
Unit
GLS238.202.01P
* 45mm
14/23
Each
Case of 10
GLS238.202.02P
* 70mm
14/23
Each
Case of 10
GLS238.202.03P
* 70mm
29/32
Each
Case of 10
GLS238.202.04P
* 80mm
29/32
Each
Case of 10
GLS238.202.05P
* 100mm
14/23
Each
Case of 10
GLS238.202.06P
* 100mm
29/32
Each
Case of 10
39
General Glassware
General Glassware
Desiccators
Glassco Desiccators, with Lid, Plain, Neutral Glass, with Porcelain Perforated Plate
Laboratory Glassware Catalogue 2012/13
Item Code
40
Internal Diameter
Pack Size
Unit
GLS249.202.01
* 150mm
Each
Each
GLS249.202.02
* 210mm
Each
Each
GLS249.202.03
* 250mm
Each
Each
GLS249.202.04
* 300mm
Each
Each
Glassco Desiccators, with Lid, Vacuum, Neutral Glass, with Porcelain Perforated Plate
Item Code
Internal Diameter
Pack Size
Unit
GLS250.202.01
* 150mm
Each
Each
GLS250.202.02
* 210mm
Each
Each
GLS250.202.03
* 250mm
Each
Each
GLS250.202.04
* 300mm
Each
Each
* denotes products not stocked
Kimble Chase scintillation vials are supplied with
caps attached, in cellular trays with alpha numeric
coordinates for fast, easy identification.
Kimble Chase Scintillation Vials
Item Code
Capacity
Cap material
Cap Liner
Cap Size
Pack Size
Unit
KIM74502-7
7mL
Urea
Cork-backed foil
15mm
200pcs
Case of 5
KIM74504-20
20mL
Polypropylene
Pulp-backed foil
22mm
500pcs
Each
General Glassware >> Desiccators & Scintillation Vials
Scintillation Vials
Wheaton Scintillation Vials (supplied with either Polypropylene or Urea caps)
Item Code
Capacity
Cap material
Cap Liner
Cap Size
Pack Size
Unit
WHE986541
20mL
Polypropylene
Metal foil
22mm
500pcs
Each
WHE986560
20mL
Polypropylene
Foamed polyethylene 24mm
500pcs
Each
WHE986561
20mL
Polypropylene
Metal foil
22mm
500pcs
Each
WHE986542
20mL
Urea
Metal foil
22mm
500pcs
Each
WHE986546
20mL
Urea
Polyseal
22mm
500pcs
Each
WHE986548
20mL
Urea
Polyethylene disc
22mm
500pcs
Each
Available in New Zealand Only.
41
General Glassware
General Glassware
Trident Vials
Samco neutral glass vials will withstand moderate temperature change.
Samco Trident Vials, Neutral Glass, without Closure
Laboratory Glassware Catalogue 2012/13
Item Code
42
Capacity
Form
Height x Diameter Neck Bore
Pack Size
Unit
SAMT101/V1
* 1.75mL
Tall Form
36x11mm
5.5mm
882pcs
Each
SAMT101/V2
* 3.5mL
Tall Form
46x12.5mm
5.5mm
666pcs
Each
SAMT101/V3
* 7.0mL
Tall Form
58x17mm
9.0mm
399pcs
Each
SAMT101/V4
* 10.5mL
Tall Form
67x17mm
9.0mm
399pcs
Each
SAMT101/V5
* 14.0mL
Tall Form
72x20mm
13.0mm
264pcs
Each
SAMT101/V6
* 21.25mL
Tall Form
86x21mm
13.0mm
231pcs
Each
SAMT101/V7
* 28.25mL
Tall Form
96x23mm
15.5mm
190pcs
Each
SAMT102/V1
* 7.0mL
Squat Form
42x20mm
13.0mm
264pcs
Each
SAMT102/V2
* 14.0mL
Squat Form
58x23mm
15.5mm
190pcs
Each
Squat Form
27.5x21mm
21.0mm
140pcs
Each
SAMT102/V3
28.25mL
* denotes products not stocked
General Glassware >> Trident & Pathology Vials
Samco Screw Caps for Trident Vials, Black Polypropylene, Foil-faced Wads
Item Code
Capacity
Pack Size
Unit
SAMT001/C1
To fit T101/V1 and T101/V2
882pcs
Each
SAMT001/C3
* To fit T101/V3 and T101/V4
399pcs
Each
SAMT001/C5
* To fit T101/V5, T101/V6 and T102/V1
264pcs
Each
SAMT001/C7
* To fit T101/V7 and T102/V2
190pcs
Each
140pcs
Each
SAMT002/C3
To fit T102/V3
Pathological Vials
Samco moulded pathological vials are made of white flint glass, which has been
sulphated for autoclaving. Spare caps are also available.
Samco Pathological Vials, White Flint Glass, with Fitted Aluminium Rubber Lined Closure
Item Code
Capacity
Type
Neck
Height x Diameter Pack Size
Unit
SAMG752/01
7.0mL
Bijou
Narrow Neck
48.5x21.9mm
288pcs
Each
SAMG752/02
* 14.0mL
McCartney
Narrow Neck
64.7x27.6mm
288pcs
Each
SAMG751/01
28.0mL
Universal
Wide Neck
82.5x28.6mm
144pcs
Each
43
General Glassware
General Glassware
Petri Dishes
KIMAX dishes have reinforced beaded edges to resist mechanical breakage and to
help in centering the bottom inside the cover. Dishes remain clear after repeated
use in wet or dry sterilisation cycles. Shelf packs contain twelve covers and twelve
bottoms, which are packed in separate boxes. Designed from Federal Specification
NNN-D-1478.
Laboratory Glassware Catalogue 2012/13
Kimble Petri Dishes
44
Item Code
Diameter
Height
Pack Size
Unit
KIM23060-6015
60mm
15mm
Each
Each/Pack of 12/Case of 72
KIM23060-10020
100mm
20mm
Each
Each/Pack of 12/Case of 72
KIM23060-15020
* 150mm
20mm
Each
Case of 24
Height
Pack Size
Unit
* 40mm
12mm
Each
Case of 10
SCH2375540
60mm
15mm
Each
Case of 10
SCH2375542
* 80mm
15mm
Each
Case of 10
SCH2375545
* 100mm
10mm
Each
Case of 10
SCH2375546
100mm
15mm
Each
Case of 10
SCH2375548
* 100mm
20mm
Each
Case of 10
SCH2375551
* 120mm
20mm
Each
Case of 10
SCH2375552
* 150mm
25mm
Each
Case of 10
SCH2375556
* 180mm
30mm
Each
Case of 10
SCH2375559
* 200mm
30mm
Each
Case of 10
SCH2375561
* 200mm
50mm
Each
Case of 10
Schott Duran Petri Dishes, Steriplan, Soda Lime Glass
Item Code
SCH2375539
Diameter
* denotes products not stocked
Schott Duran Watch Glasses, with Fused Rim, Soda Lime Glass
Item Code
Diameter
Pack Size
Unit
SCH2332124
* 40mm
Each
Case of 10
SCH2332132
* 50mm
Each
Case of 10
SCH2332134
* 60mm
Each
Case of 10
SCH2332138
* 70mm
Each
Case of 10
SCH2332141
* 80mm
Each
Case of 10
SCH2332143
* 90mm
Each
Case of 10
SCH2332146
* 100mm
Each
Case of 10
SCH2332151
* 120mm
Each
Case of 10
SCH2332152
* 125mm
Each
Case of 10
SCH2332157
* 150mm
Each
Case of 10
SCH2332161
* 200mm
Each
Case of 10
SCH2332166
* 250mm
Each
Each
General Glassware >> Petri Dishers & Watch Glasses
Watch Glasses
45
General Glassware
General Glassware
Separating Funnels
Glassco separating funnels are produced from ASTM E-438 Type 1 Class A BORO
3.3 heat resistant glass. All Glassco funnels are manufactured as per ISO 4800
standard. The printing is done in white colour.
Glassco Squibb Separating Funnels, Plain, PTFE Stopcock
Item Code
Laboratory Glassware Catalogue 2012/13
GLS149.202.02
Capacity
* 50mL
Stopper Size
Bore
Pack Size
Unit
19/26
2.5mm
Each
Each
GLS149.202.03
100mL
19/26
2.5mm
Each
Each
GLS149.202.04
250mL
29/32
4mm
Each
Each
GLS149.202.05
500mL
29/32
4mm
Each
Each
GLS149.202.06
1,000mL
29/32
6mm
Each
Each
GLS149.202.07
2,000mL
29/32
6mm
Each
Each
Stopper Size
Bore
Pack Size
Unit
19/26
2.5mm
Each
Each
Glassco Pear Separating Funnels, Plain, PTFE Stopcock
Item Code
GLS152.202.02
Capacity
* 50mL
GLS152.202.03
100mL
19/26
2.5mm
Each
Each
GLS152.202.05
500mL
29/32
4mm
Each
Each
GLS152.202.06
1,000mL
29/32
6mm
Each
Each
GLS152.202.07
* 2,000mL
29/32
6mm
Each
Each
Glassco Cylindrical Dropping Funnels, Graduated, PTFE Stopcock
Item Code
46
Capacity
Stopper Size
Bore
Pack Size
Unit
GLS158.202.04
* 250mL
29/32
4mm
Each
Each
GLS158.202.05
* 500mL
29/32
4mm
Each
Each
GLS158.202.06
* 1,000mL
29/32
6mm
Each
Each
* denotes products not stocked
Glassco Liebig Condensers, Glass Hose Connections
Item Code
Effective Length
Cone Size
Socket Size
Pack Size
Unit
GLS182.202.01
160mm
14/23
14/23
Each
Each
* 160mm
19/26
19/26
Each
Each
250mm
19/26
19/26
Each
Each
GLS182.202.03
250mm
24/29
24/29
Each
Each
GLS182.202.04
* 300mm
19/26
19/26
Each
Each
GLS182.202.05
* 300mm
24/29
24/29
Each
Each
GLS182.202.06
* 300mm
29/32
29/32
Each
Each
GLS182.202.10
* 400mm
24/29
24/29
Each
Each
GLS182.202.11
* 400mm
29/32
29/32
Each
Each
Cone Size
Socket Size
Pack Size
Unit
GLS182.202.01A
GLS182.202.02
General Glassware >> Separating Funnels & Condensers
Condensers
Glassco Coil Condensers, Glass Hose Connections
Item Code
Effective Length
GLS183.202.01
* 160mm
14/23
14/23
Each
Each
GLS183.202.01A
* 160mm
19/26
19/26
Each
Each
GLS183.202.03
* 250mm
19/26
19/26
Each
Each
GLS183.202.04
* 250mm
24/29
24/29
Each
Each
GLS183.202.04A
* 250mm
29/32
29/32
Each
Each
GLS183.202.05
* 300mm
24/29
24/29
Each
Each
GLS183.202.06
* 300mm
29/32
29/32
Each
Each
GLS183.202.07
* 400mm
29/32
29/32
Each
Each
47
General Glassware
General Glassware
Glassco Allihn Condensers, Glass Hose Connections
Item Code
Effective Length
Cone Size
Socket Size
Pack Size
Unit
GLS190.202.05
* 160mm
14/23
14/23
Each
Each
GLS190.202.06
* 160mm
19/26
19/26
Each
Each
GLS190.202.07
* 250mm
14/23
14/23
Each
Each
GLS190.202.08
* 250mm
19/26
19/26
Each
Each
GLS190.202.09
* 250mm
24/29
24/29
Each
Each
GLS190.202.10
* 300mm
24/29
24/29
Each
Each
GLS190.202.11
* 300mm
29/32
29/32
Each
Each
GLS190.202.12
* 400mm
24/29
24/29
Each
Each
GLS190.202.13
* 400mm
29/32
29/32
Each
Each
Cone Size
Socket Size
Pack Size
Unit
Soxhlet Extractors
Laboratory Glassware Catalogue 2012/13
Item Code
48
Capacity
GLS211.202.04
* 100mL
29/32
45/40
Each
Each
GLS211.202.05
* 150mL
29/32
45/40
Each
Each
GLS211.202.06
* 250mL
29/32
45/40
Each
Each
GLS211.202.08
* 500mL
29/32
60/46
Each
Each
GLS211.202.09
* 1,000mL
29/32
71/51
Each
Each
* denotes products not stocked
Glassco Filtration Assembly, 47mm, All Glass, with Funnel, Fritted Base, Cap and Clamp
Item Code
Funnel
Flask
Filter Diameter
Pack Size
Unit
GLS258.202.01
300mL
1,000mL
47mm
Each
Each
Millipore Glass Filter Holders, Borosilicate Glass Funnel and Base, Anodised Aluminium Spring Clamp, Silicone Stopper
Filter Diameter
Pack Size
Unit
Coarse-frit glass filter support 300mL
47mm
Each
Each
PTFE-faced funnel and base
47mm
Each
Each
Item Code
Part
MILXX1004700
MILXX1004710
Funnel Capacity
300mL
General Glassware >> Condensers & Filtration Glassware
Filtration Glassware
49
Laboratory Glassware Catalogue 2012/13
General Glassware
General Glassware
50
Glassco Filter Gooch Crucibles, with Sintered Disc, Borosilicate Glass
Item Code
Capacity
Porosity
Pack Size
Unit
GLS255.G00.01
* 15mL
0
Each
Case of 10
GLS255.G01.01
* 15mL
1
Each
Case of 10
GLS255.G02.01
* 15mL
2
Each
Case of 10
GLS255.G03.01
* 15mL
3
Each
Case of 10
GLS255.G04.01
* 15mL
4
Each
Case of 10
GLS255.G00.02
* 30mL
0
Each
Case of 10
GLS255.G01.02
* 30mL
1
Each
Case of 10
GLS255.G02.02
* 30mL
2
Each
Case of 10
GLS255.G03.02
* 30mL
3
Each
Case of 10
GLS255.G04.02
* 30mL
4
Each
Case of 10
GLS255.G00.03
* 50mL
0
Each
Case of 10
GLS255.G01.03
* 50mL
1
Each
Case of 10
GLS255.G02.03
* 50mL
2
Each
Case of 10
GLS255.G03.03
* 50mL
3
Each
Case of 10
GLS255.G04.03
* 50mL
4
Each
Case of 10
* denotes products not stocked
Item Code
Capacity
Porosity
Pack Size
Unit
GLS256.G00.01
* 35mL
0
Each
Case of 2
GLS256.G01.01
* 35mL
1
Each
Case of 2
GLS256.G02.01
* 35mL
2
Each
Case of 2
GLS256.G03.01
* 35mL
3
Each
Case of 2
GLS256.G04.01
* 35mL
4
Each
Case of 2
GLS256.G00.02
* 80mL
0
Each
Case of 2
GLS256.G01.02
* 80mL
1
Each
Case of 2
GLS256.G02.02
* 80mL
2
Each
Case of 2
GLS256.G03.02
* 80mL
3
Each
Case of 2
GLS256.G04.02
* 80mL
4
Each
Case of 2
GLS256.G00.03
* 200mL
0
Each
Case of 2
GLS256.G01.03
* 200mL
1
Each
Case of 2
GLS256.G02.03
* 200mL
2
Each
Case of 2
GLS256.G03.03
* 200mL
3
Each
Case of 2
GLS256.G04.03
* 200mL
4
Each
Case of 2
GLS256.G00.04
* 500mL
0
Each
Case of 2
GLS256.G01.04
* 500mL
1
Each
Case of 2
GLS256.G02.04
* 500mL
2
Each
Case of 2
GLS256.G03.04
* 500mL
3
Each
Case of 2
GLS256.G04.04
* 500mL
4
Each
Case of 2
GLS256.G00.05
* 1,000mL
0
Each
Case of 2
GLS256.G01.05
* 1,000mL
1
Each
Case of 2
GLS256.G02.05
* 1,000mL
2
Each
Case of 2
GLS256.G03.05
* 1,000mL
3
Each
Case of 2
GLS256.G04.05
* 1,000mL
4
Each
Case of 2
General Glassware >> Filtration Glassware
Glassco Buchner Funnels, with Sintered Disc, Borosilicate Glass
51
General Glassware
General Glassware
Jars
Cospak Clear Jars, Caps Sold Separately
Item Code
Type
Capacity
Neck Finish
Height
Diameter
Pack Size
Unit
COSH0466
* Clear jar
30mL
38mm
46mm
40mm
160pcs
Each
COSTG1146
* Clear jar
125mL
48mm
42pcs
Each
COSH15131
Clear jar
250mL
63mm
104mm
67mm
48pcs
Each
COSJA500C
* Clear jar
500mL
63mm
148mm
78mm
COS3830
White poly cap
50pcs
Each
38mm
Each
Each
COS4832
* Black phenolic wadded cap
48mm
Each
Each
COS6330
* White poly cap
63mm
Each
Each
COS6331
* White poly wadded cap
63mm
Each
Each
Laboratory Glassware Catalogue 2012/13
Available in Australia Only
52
Solindex Jars
Item Code
Type
Pack Size
Unit
LABSOL003
Jar solindex
Each
Each/Case of 25
LABSOL001
* Mixing unit for ADMI solindex
Each
Each
LABSOL002
* Solindex blades
Each
Each
LABSOL003
Jar solindex
Each
Each/Case of 25
Available in New Zealand Only
* denotes products not stocked
Kimble Chase Babcock Bottles
Item Code
Type
Pack Size
Unit
KIM509-50
* 50% 9g paley cheese
Each
Case of 3
KIM2085S-50
* Cream test 9g sealed
Each
Case of 12
Available in Australia Only
General Glassware >> Jars & More
Babcock Bottles
Mojonnier Tubes
Funke Gerber Mojonnier Tubes
Item Code
Type
Stopper
Pack Size
Unit
FG3870
Round bulb
Cork
Each
Each
FG3871
Flat topped bulb
Cork
Each
Each
Available in New Zealand Only
Mojonnier Flasks
Item Code
PEDMAJSTD
Type
* Medium wall
Pack Size
Unit
Each
Each
Available in Australia Only
53
General Glassware
General Glassware
Stirring Rods
Item Code
Type
Pack Size
Unit
CSUROD
6x200mm
Each
Each/Case of 10
6x300mm
Each
Each
Available in New Zealand Only
RBI434408
Laboratory Glassware Catalogue 2012/13
Available in Australia Only
Miscellaneous
Item Code
Type
Volume
Cone
Pack Size
Unit
CSUTILT/10
Tilt measure
10mL
24/29
Each
Each
CSUWBOAT.10
Weighing boat glass
10mL
Each
Each
Available in New Zealand Only
54
* denotes products not stocked
• LabServ microscope slides are cut from water white, corrosion resistant glass
• All slides have ground and polished edges to prevent injury to fingers
• Superfrost and Colorfrost slides have a permanent opaque frosted area which
makes written information permanent and easier to read
• Pre-cleaned
• Individually selected
• Annealed to minimise chipping and breakage
• Thin, flat and resistant to corrosion or fogging
Microscope Slides
Item Code
Type
Dimensions mm
Pack Size
Unit
LBS2950RC
Plain
75x25mm
100pcs
Each
LBS2951RC
Frosted
75x25mm
100pcs
Each
LBS4951
Superfrost white
75x25mm
100pcs
Each/Case of 35
LBS6951
Colorfrost green
75x25mm
100pcs
Each/Case of 35
LBS7951
Colorfrost pink
75x25mm
100pcs
Each/Case of 35
LBS8951
Colorfrost yellow
75x25mm
100pcs
Each/Case of 35
LBSP4981
Polysine frosted
75x25mm
72pcs
Each
LBS4951PLUS
Superfrost plus
75x25mm
72pcs
Each
General Glassware >> Stirring Rods, Miscellaneous & Microscope Slides
LabServ Microscope Slides
55
LabServ Coverslips
Item Code
Type
Dimensions mm
Pack Size
Unit
LBS18X18-1
Coverslip No 1
18x18mm
242pcs
Each/Case of 10
LBS22X22-1
Coverslip No 1
22x22mm
162pcs
Each/Case of 10
LBS22X30-1
Coverslip No 1
22x30mm
119pcs
Each/Case of 10
LBS22X40-1
Coverslip No 1
22x40mm
89pcs
Each/Case of 10
LBS22X50-1
Coverslip No 1
22x50mm
62pcs
Each/Case of 10
LBS22X60-1
Coverslip No 1
22x60mm
59pcs
Each/Case of 10
LBS24X50-1
Coverslip No 1
24x50mm
65pcs
Each/Case of 10
Laboratory Glassware Catalogue 2012/13
General Glassware
General Glassware
56
* denotes products not stocked
Culture Tubes
58
Closures62
Centrifuge Tubes
63
Specimen Tubes
64
Durham Tubes
65
Haematocrit Tubes
65
NMR Tubes
66
test,culture &
specialty tubes
Test, Culture & Specialty Tubes
Test, Culture & Specialty Tubes
Disposable Culture Tubes
The LabServ borosilicate rimless disposable culture tubes have a low thermal
expansion coefficient and high chemical resistance, making them ideal for use in the
medical, pharmaceutical and analytical industries. The LabServ borosilicate rimless
disposable culture tubes conform to USP, Type I and ASTM Type I, Class B standards
and are available in a wide range of sizes from 6x50mm to 25x150mm.
LabServ Disposable Culture Tubes, Borosilicate Glass, Rimless
Laboratory Glassware Catalogue 2012/13
Item Code
58
Diameter x Height
Pack Size
Unit
LBSDCT650
6x50mm
500pcs
Each/Case of 8
LBSDCT1075
10x75mm
250pcs
Each/Case of 6
LBSDCT1275
12x75mm
250pcs
Each/Case of 6
LBSDCT13100
13x100mm
250pcs
Each/Case of 6
LBSDCT16100
16x100mm
250pcs
Each/Case of 4
LBSDCT16125
16x125mm
250pcs
Each/Case of 4
LBSDCT16150
16x150mm
250pcs
Each/Case of 4
LBSDCT18150
18x150mm
125pcs
Each/Case of 4
LBSDCT20150
* 20x150mm
125pcs
Case of 4
LBSDCT25150
* 25x150mm
50pcs
Case of 6
Available in Australia Only
Borosilicate glass KIMAX-51 composition assures the best all-around chemical durability of commercial glasses now
available for laboratory ware. Complies with ASTM Specification E438, Type I, Class B glass requirements. KIMAX-51
has excellent chemical resistance against sodium leaching - a factor common in soda lime glass products. These are
premium quality tubes with sturdy, uniform bottoms and consistent lengths. The 10 and 12 x 75 mm sizes are suitable for
cell washing procedures. Tubes are packed in convenient trays for ease of use on bench tops and in drawers. The 10 and
12 x 75 mm sizes fit into Kimble 73510 stainless steel dispensers. The 6 x 50 mm size is often referred to as a “Durham
tube”. Trays are shrink wrapped in plastic film with tubes remaining in constant alignment for protection against in-transit
breakage and contamination. Designed from ASTM Specification E890.
* denotes products not stocked
Item Code
Diameter x Height
Pack Size
Unit
CSE73500-650
6x50mm
1000pcs
Each
CSE73500-1075
10x75mm
1000pcs
Each
CSE73500-1275
12x75mm
1000pcs
Each
CSE73500-13100
13x100mm
1000pcs
Each
CSE73500-16100
16x100mm
1000pcs
Each
CSE73500-16125
16x125mm
1000pcs
Each
CSE73500-16150
16x150mm
1000pcs
Each
CSE73500-18150
18x150mm
500pcs
Each
CSE73500-20150
* 20x150mm
500pcs
Each
CSE73500-25150
25x150mm
500pcs
Each
Available in Australia Only
Kimble Chase Disposable Culture Tubes, Borosilicate Glass, Rimless
Item Code
Diameter x Height
Pack Size
Unit
KIM73500-650
6x50mm
500pcs
Case of 2
KIM73500-1075
10x75mm
250pcs
Each/Case of 4
KIM73500-1275
12x75mm
250pcs
Each/Case of 4
KIM73500-13100
13x100mm
250pcs
Each/Case of 4
KIM73500-16100
16x100mm
250pcs
Each/Case of 4
KIM73500-16125
16x125mm
250pcs
Each/Case of 4
KIM73500-16150
16x150mm
250pcs
Case of 4
KIM73500-18150
18x150mm
125pcs
Each/Case of 4
KIM73500-18150
18x150mm
125pcs
Each/Case of 4
KIM73500-20150
20x150mm
125pcs
Case of 4
KIM73500-25150
25x150mm
125pcs
Case of 4
Test, Culture & Specially Tubes >> Disposable Culture Tubes
Kimble Chase Disposable Culture Tubes, Borosilicate Glass, Rimless
Available in New Zealand Only
59
Test, Culture & Specialty Tubes
Test, Culture & Specialty Tubes
Reusable Culture Tubes
KIMAX culture tubes are made from KG-33 glass tubing, with fire-polished top rims
and uniform wall thickness for maximum heat transfer and chemical resistance.
Durable white ceramic enamel marking spot. Designed from ASTM Specification
E982, Type IV requirements.
Kimble Chase Reusable Culture Tubes, with Rim
Laboratory Glassware Catalogue 2012/13
Item Code
60
Diameter x Height
Overflow Capacity
Pack Size
Unit
KIM45048-1075
* 10x75mm
4mL
72pcs
Case of 10
KIM45048-1275
* 12x75mm
6mL
72pcs
Case of 10
KIM45048-13100
13x100mm
10mL
72pcs
Case of 10
KIM45048-16100
* 16x100mm
15mL
72pcs
Case of 8
KIM45048-16125
* 16x125mm
20mL
72pcs
Case of 8
KIM45048-16150
16x150mm
24mL
72pcs
Case of 8
KIM45048-18150
18x150mm
28mL
72pcs
Case of 8
KIM45048-20150
* 20x150mm
36mL
72pcs
Case of 4
KIM45048-25150
* 25x150mm
55mL
72pcs
Case of 4
* denotes products not stocked
Kimble Chase Reusable Culture Tubes, with PTFE-Faced Rubber Liner Threaded Cap Unattached
Item Code
Diameter x Height
Overflow Capacity
Pack Size
Unit
KIM45066A-13100
* 13x100mm
8mL
72pcs
Case of 4
KIM45066A-16100
* 16x100mm
12mL
72pcs
Case of 4
KIM45066A-16125
* 16x125mm
16mL
72pcs
Case of 4
KIM45066A-16150
* 16x150mm
20mL
72pcs
Case of 4
KIM45066A-20125
* 20x125mm
25mL
48pcs
Case of 4
KIM45066A-20150
* 20x150mm
30mL
48pcs
Case of 4
KIM45066A-25150
* 25x150mm
50mL
36pcs
Case of 4
Test, Culture & Specially Tubes >> Reusable Culture Tubes
KIMAX culture tubes are made from tubing with uniform wall thickness for maximum
heat transfer and chemical resistance. Thread finish complies with Glass Packaging
Institute (GPI) requirements. Cap has a PTFE-faced rubber liner and is not attached.
Designed from ASTM E982, Type VI, Class B requirements.
61
Test, Culture & Specialty Tubes
Test, Culture & Specialty Tubes
Test Tube Closures
Closures for culture tubes and flasks. Colour Coded - natural, red, green, yellow and
blue available.
Kimble Chase KIM-KAP, Polypropylene
Laboratory Glassware Catalogue 2012/13
Item Code
62
Colour
Diameter
Pack Size
Unit
KIM73660-13
* Natural
13mm
500pcs
Case of 2
KIM73660-16
* Natural
16mm
500pcs
Case of 2
KIM73660-18
* Natural
18mm
500pcs
Case of 2
KIM73660-20
* Natural
20mm
250pcs
Case of 2
KIM73660-25
* Natural
25mm
250pcs
Case of 2
KIM73660-38
* Natural
38mm
125pcs
Case of 2
* denotes products not stocked
Glassco Centrifuge Tubes, Conical Bottom, Graduated
Item Code
OD x height
Capacity
Pack Size
Unit
GLS088.202.01
* 13x100mm
5mL
50pcs
Each
GLS088.202.02
* 15x110mm
10mL
50pcs
Each
GLS088.202.03
* 17x120mm
15mL
50pcs
Each
GLS088.202.04
* 22x125mm
25mL
50pcs
Each
GLS088.202.05
* 28x125mm
50mL
50pcs
Each
Capacity
Pack Size
Unit
Glassco Centrifuge Tubes, Conical Bottom, Plain
Item Code
OD x height
GLS089.202.02
* 13x100mm
5mL
50pcs
Each
GLS089.202.03
* 15x110mm
10mL
50pcs
Each
GLS089.202.05
* 17x120mm
15mL
50pcs
Each
GLS089.202.06
* 22x125mm
25mL
50pcs
Each
GLS089.202.07
* 28x125mm
50mL
50pcs
Each
Capacity
Pack Size
Unit
Glassco Centrifuge Tubes, Round Bottom, Graduated
Item Code
OD x height
GLS094.202.01
* 16x110mm
12mL
50pcs
Each
GLS094.202.02
* 24x110mm
30mL
50pcs
Each
GLS094.202.03
* 28x110mm
40mL
50pcs
Each
GLS094.202.04
* 30x110mm
50mL
50pcs
Each
GLS094.202.05
* 45x110mm
100mL
50pcs
Each
GLS094.202.07
* 55x116mm
200mL
50pcs
Each
Test, Culture & Specially Tubes >> Test Tubes Closures & Centrifuge Tubes
Centrifuge Tubes
63
Laboratory Glassware Catalogue 2012/13
Test, Culture & Specialty Tubes
Test, Culture & Specialty Tubes
64
Specimen Tubes
Samco Specimen Tubes, Soda Glass, Flat Bottom, with Polyethylene Push Cap
Item Code
Diameter x Height
Wall Thickness
Pack Size
Unit
SAMG050/17
* 10x38mm
0.6mm
250pcs
Each
SAMG050/18
* 10x50mm
0.6mm
250pcs
Each
SAMG050/19
* 12x38mm
0.85mm
100pcs
Each
SAMG050/20
12x50mm
0.85mm
100pcs
Each
SAMG050/22
* 12x75mm
0.85mm
100pcs
Each
SAMG050/24
16x50mm
0.85mm
100pcs
Each
SAMG050/25
* 16x75mm
0.85mm
100pcs
Each
SAMG050/26
19x50mm
0.85mm
100pcs
Each
SAMG050/27
* 19x75mm
0.85mm
100pcs
Each
SAMG050/28
25x50mm
0.85mm
100pcs
Each
SAMG050/29
* 25x75mm
0.85mm
100pcs
Each
SAMG050/30
* 25x100mm
0.85mm
100pcs
Each
SAMG050/31
* 25x150mm
0.85mm
100pcs
Each
* denotes products not stocked
Samco neutral glass test tubes will withstand moderate temperature change.
Samco Durham Tubes, Neutral Glass
Item Code
Diameter x Height
Wall Thickness
Pack Size
Unit
SAMG010/21
6.5x25mm
0.65mm
250pcs
Each
SAMG010/22
* 6.5x30mm
0.65mm
250pcs
Each
SAMG010/23
* 7.5x35mm
0.65mm
250pcs
Each
SAMG010/24
* 7.5x50mm
0.65mm
250pcs
Each
Haematocrit Tubes
Test, Culture & Specially Tubes >> Specimen Tubes & More
Durham Tubes
Kimble Chase brand micro-haematocrit tubes are manufactured from soda lime glass, packed in plastic vials with
reclosable snap-lock caps to maintain cleanliness. Ends may be sealed by flame, sealing clay or patented caps. They
are available in borosilicate glass as a special order. Heparinised capillary tubes are treated to prevent blood clotting.
Ammonium Heparin does not interfere with sodium identification.
Kimble Chase Haematocrit Tubes
Item Code
Type
Width (mm)
Pack Size
Unit
CSE2501
Heparin
75
200pcs
Each/Case of 12
CSE2502
Plain
75
200pcs
Each/Case of 12
65
Test, Culture & Specialty Tubes
Test, Culture & Specialty Tubes
NMR Tubes
Kontes thrift tubes are manufactured from KIMAX® N-51A borosilicate glass and
their performance is assured by state of the art manufacturing and inspection
processes for camber and concentricity. Caps attached.
Kontes NMR Tubes, Thrift Quality, 5mm, N-51A Borosilicate Glass, Caps Attached
Laboratory Glassware Catalogue 2012/13
Item Code
66
Approx.
Frequency (MHz)
Length (in)
Wall Thickness
Pack Size
Unit
KON897150-0007
* 500
7
0.38mm
5pcs
Each
KON897150-0008
* 500
8
0.38mm
5pcs
Each
KON897140-0007
* 400
7
0.38mm
5pcs
Each
KON897140-0008
* 400
8
0.38mm
5pcs
Each
KON897130-0007
* 300
7
0.38mm
5pcs
Each
KON897130-0008
* 300
8
0.38mm
5pcs
Each
KON897120-0007
* 200
7
0.38mm
5pcs
Each
KON897110-0007
* >200
7
0.38mm
5pcs
Each
KON897110-0008
* >200
8
0.38mm
5pcs
Each
* denotes products not stocked
Flasks68
Stoppers74
Adapters75
interchangeable glassware
Interchangeable Glassware
Interchangeable Glassware
Flasks
Glassco flasks are manufactured from ASTM 438 Type 1 Class BORO 3.3 heat
resistant glass. All come with thick uniform wall thickness and are printed with white
enamel. All flasks comply to their respective DIN/ISO/ASTM and USP standards.
Laboratory Glassware Catalogue 2012/13
Glassco Round Bottom Flasks, Single Neck
68
Item Code
Capacity
Socket Size
Approx.
Overall Height
Diameter
Pack Size
Unit
GLS057.202.05
25mL
14/23
65mm
33mm
Each
Case of 10
GLS057.202.06
25mL
19/26
85mm
41mm
Each
Case of 10
GLS057.202.08
50mL
14/23
90mm
51mm
Each
Case of 10
GLS057.202.09
50mL
19/26
90mm
51mm
Each
Case of 10
GLS057.202.10
50mL
24/29
115mm
51mm
Each
Case of 10
GLS057.202.11
100mL
14/23
105mm
64mm
Each
Case of 10
GLS057.202.12
100mL
19/26
105mm
64mm
Each
Case of 10
GLS057.202.13
100mL
24/29
105mm
64mm
Each
Case of 10
GLS057.202.20
250mL
14/23
140mm
85mm
Each
Case of 10
GLS057.202.21
250mL
19/26
140mm
85mm
Each
Case of 10
GLS057.202.22
250mL
24/29
140mm
85mm
Each
Case of 10
GLS057.202.25
500mL
19/26
163mm
105mm
Each
Case of 10
GLS057.202.30
1,000mL
24/29
200mm
131mm
Each
Case of 10
* denotes products not stocked
Item Code
Capacity
GLS059.202.01
* 50mL
GLS059.202.02
* 50mL
GLS059.202.03
100mL
Centre Socket Size
Side Socket Size
Pack Size
Unit
24/29
14/23
Each
Each
29/32
14/23
Each
Each
24/29
14/23
Each
Each
GLS059.202.04
100mL
24/29
19/26
Each
Each
GLS059.202.05
* 100mL
29/32
14/23
Each
Each
GLS059.202.06
250mL
24/29
14/23
Each
Each
GLS059.202.07
250mL
24/29
19/26
Each
Each
GLS059.202.08
* 250mL
29/32
14/23
Each
Each
GLS059.202.09
* 500mL
24/29
14/23
Each
Each
GLS059.202.10
* 500mL
24/29
19/26
Each
Each
GLS059.202.11
* 500mL
29/32
14/23
Each
Each
GLS059.202.12
* 1,000mL
24/29
14/23
Each
Each
GLS059.202.13
* 1,000mL
24/29
19/26
Each
Each
GLS059.202.14
* 1,000mL
29/32
14/23
Each
Each
GLS059.202.15
* 2,000mL
34/35
19/26
Each
Each
Interchangeable Glassware >> Flasks
Glassco Round Bottom Flasks, Two Necks
69
Laboratory Glassware Catalogue 2012/13
Interchangeable Glassware
Interchangeable Glassware
70
Glassco Round Bottom Flasks, Three Necks, Angular
Item Code
Capacity
Centre Socket Size
Side Socket Size
Pack Size
Unit
GLS060.202.01
* 100mL
19/26
14/23
Each
Each
GLS060.202.02
* 100mL
24/29
14/23
Each
Each
GLS060.202.03
* 100mL
24/29
19/26
Each
Each
GLS060.201.03A
* 100mL
29/32
14/23
Each
Each
GLS060.202.04
* 250mL
19/26
19/26
Each
Each
GLS060.202.05
250mL
24/29
14/23
Each
Each
GLS060.202.06
* 250mL
24/29
19/26
Each
Each
GLS060.202.07
* 250mL
29/32
14/23
Each
Each
GLS060.202.08
* 250mL
29/32
19/26
Each
Each
GLS060.201.08A
* 250mL
29/32
29/32
Each
Each
GLS060.202.09
* 500mL
24/29
14/23
Each
Each
GLS060.202.10
* 500mL
24/29
19/26
Each
Each
GLS060.202.11
* 500mL
29/32
14/23
Each
Each
GLS060.202.12
* 500mL
29/32
19/26
Each
Each
GLS060.201.12A
* 500mL
29/32
29/32
Each
Each
GLS060.202.13
* 1,000mL
24/29
14/23
Each
Each
GLS060.202.14
* 1,000mL
24/29
19/26
Each
Each
GLS060.202.15
* 1,000mL
29/32
14/23
Each
Each
GLS060.202.16
* 1,000mL
29/32
19/26
Each
Each
GLS060.202.17
* 1,000mL
29/32
29/32
Each
Each
GLS060.202.18
* 2,000mL
24/29
19/26
Each
Each
GLS060.202.19
* 2,000mL
29/32
24/29
Each
Each
GLS060.202.20
* 2,000mL
29/32
29/32
Each
Each
* denotes products not stocked
Item Code
Capacity
Socket Size
Approx. Diameter
Approx. Overall
Height
Pack Size
Unit
GLS062.202.06
* 25mL
14/23
38mm
90mm
Each
Case of 10
GLS062.202.07
* 50mL
14/23
48mm
110mm
Each
Case of 10
GLS062.202.09
* 100mL
14/23
58mm
125mm
Each
Case of 10
Centre
Socket Size
Side
Socket Size
Approx. Overall
Height
Pack Size
Unit
Pear Shaped Flasks, Two Necks
Item Code
Capacity
GLS063.202.01
* 50mL
14/23
14/23
110mm
Each
Each
GLS063.202.02
* 100mL
14/23
14/23
125mm
Each
Each
Volumetric Glassware >> Flasks
Pear Shaped Flasks, Single Neck
Evaporating Flasks
Item Code
Capacity
Socket Size
Approx. Overall
Height
Pack Size
Unit
GLS069.202.01
* 50mL
29/32
94mm
Each
Case of 10
GLS069.202.02
* 100mL
24/29
110mm
Each
Case of 10
GLS069.202.03
* 100mL
29/32
110mm
Each
Case of 10
GLS069.202.04
* 250mL
24/29
140mm
Each
Case of 10
GLS069.202.05
* 250mL
29/32
140mm
Each
Case of 10
GLS069.202.06
* 500mL
24/29
170mm
Each
Case of 10
GLS069.202.07
* 500mL
29/32
170mm
Each
Case of 10
GLS069.202.08
* 1,000mL
24/29
210mm
Each
Case of 10
GLS069.202.09
* 1,000mL
29/32
210mm
Each
Case of 10
GLS069.202.10
* 2,000mL
29/32
250mm
Each
Case of 6
71
Kjeldahl Flasks
Item Code
Capacity
Socket Size
Approx. Height
Pack Size
Unit
GLS070.202.01
* 50mL
19/26
162mm
Each
Case of 2
GLS070.202.02
* 100mL
19/26
162mm
Each
Case of 2
GLS070.202.03
* 100mL
24/29
265mm
Each
Case of 2
GLS070.202.04
* 300mL
24/29
295mm
Each
Case of 2
GLS070.202.05
* 500mL
24/29
305mm
Each
Case of 2
GLS070.202.06
* 800mL
24/29
325mm
Each
Each
Laboratory Glassware Catalogue 2012/13
Interchangeable Glassware
Interchangeable Glassware
72
* denotes products not stocked
Item Code
Capacity
Socket Size
Approx.
Overall Diameter
Approx.
Overall Height
Pack Size
Unit
GLS071.202.06
* 25mL
14/23
75mm
42mm
Each
Case of 10
GLS071.202.07
* 25mL
19/26
75mm
42mm
Each
Case of 10
GLS071.202.08
* 50mL
14/23
85mm
51mm
Each
Case of 10
GLS071.202.09
50mL
19/26
85mm
51mm
Each
Case of 10
GLS071.202.10
50mL
24/29
85mm
64mm
Each
Case of 10
GLS071.202.11
* 100mL
14/23
105mm
64mm
Each
Case of 10
GLS071.202.12
100mL
19/26
105mm
64mm
Each
Case of 10
GLS071.202.13
100mL
24/29
105mm
64mm
Each
Case of 10
GLS071.202.14
* 100mL
29/32
105mm
64mm
Each
Case of 10
GLS071.202.15
* 150mL
19/26
118mm
74mm
Each
Case of 10
GLS071.202.16
* 150mL
24/29
118mm
74mm
Each
Case of 10
GLS071.202.17
* 150mL
29/32
118mm
74mm
Each
Case of 10
GLS071.202.18
* 250mL
19/26
140mm
85mm
Each
Case of 10
GLS071.202.19
* 250mL
24/29
140mm
85mm
Each
Case of 10
GLS071.202.20
* 250mL
29/32
140mm
85mm
Each
Case of 10
GLS071.202.22
* 500mL
19/26
175mm
105mm
Each
Case of 10
GLS071.202.22A
* 500mL
24/29
175mm
105mm
Each
Case of 10
GLS071.202.23
* 500mL
29/32
175mm
105mm
Each
Case of 10
GLS071.202.25
* 1,000mL
24/29
220mm
131mm
Each
Case of 10
GLS071.202.26
* 1,000mL
29/32
220mm
131mm
Each
Case of 10
GLS071.202.27
* 1,000mL
34/35
220mm
131mm
Each
Case of 10
GLS071.202.28
* 2,000mL
29/32
280mm
166mm
Each
Case of 6
GLS071.202.29
* 2,000mL
34/35
280mm
166mm
Each
Case of 6
Volumetric Glassware >> Flasks
Conical Flasks
73
Stoppers
Glassco Stoppers, Hollow, Flat Bottom
Item Code
Socket Size
Shape
Pack Size
Unit
GLS011.202.01
* 10/19
Hexagonal
Each
Case of 100
GLS011.202.02
* 12/21
Hexagonal
Each
Case of 100
GLS011.202.02A
14/23
Hexagonal
Each
Case of 100
GLS011.202.03
19/26
Hexagonal
Each
Case of 100
GLS011.202.04
24/29
Hexagonal
Each
Case of 100
GLS011.202.05
29/32
Hexagonal
Each
Case of 100
GLS011.202.06
34/35
Hexagonal
Each
Case of 100
Laboratory Glassware Catalogue 2012/13
Interchangeable Glassware
Interchangeable Glassware
74
* denotes products not stocked
Glassco interchangeable glassware is manufactured from ASTM E-438 Class
A BORO 3.3 glass. All joints are first made on semi automatic machines and
are then ground with diamond tools for better taper and precision, and then
polished to give better finish. All the joints go through strict checks on high
vacuum machines for leak check. The different kinds of adapters are then
prepared by skilled glassblowers as per the respective standards.
Glassco Reduction Adapters
Item Code
GLS013.202.01
Socket Size
Cone Size
Pack Size
Unit
* 14/23
14/23
Each
Case of 10
GLS013.202.01A
14/23
19/26
Each
Case of 10
GLS013.202.02
14/23
24/29
Each
Case of 10
GLS013.202.03
14/23
29/32
Each
Case of 10
GLS013.202.04
19/26
24/29
Each
Case of 10
GLS013.202.05
19/26
29/32
Each
Case of 10
GLS013.202.06
19/26
34/35
Each
Case of 10
GLS013.202.07
* 19/26
40/38
Each
Case of 10
GLS013.202.08
* 19/26
45/40
Each
Case of 10
GLS013.202.09
* 19/26
55/44
Each
Case of 10
GLS013.202.10
24/29
29/32
Each
Case of 10
GLS013.202.11
24/29
34/35
Each
Case of 10
GLS013.202.12
* 24/29
40/38
Each
Case of 10
GLS013.202.13
* 24/29
45/40
Each
Case of 10
GLS013.202.14
24/29
50/42
Each
Case of 10
GLS013.202.15
* 24/29
55/44
Each
Case of 10
GLS013.202.16
29/32
34/35
Each
Case of 10
GLS013.202.17
* 29/32
40/38
Each
Case of 10
GLS013.202.18
* 29/32
45/40
Each
Case of 10
GLS013.202.19
* 34/35
40/38
Each
Case of 10
GLS013.202.20
* 34/35
45/40
Each
Case of 10
GLS013.202.21
* 34/35
50/42
Each
Case of 10
Volumetric Glassware >> Stppers & Adapters
Adapters
75
Laboratory Glassware Catalogue 2012/13
Interchangeable Glassware
Interchangeable Glassware
76
Glassco Expansion Adapters
Item Code
Socket Size
Cone Size
Pack Size
Unit
GLS014.202.01
19/26
14/23
Each
Case of 10
GLS014.202.02
24/29
14/23
Each
Case of 10
GLS014.202.03
24/29
19/26
Each
Case of 10
GLS014.202.03A
29/32
14/23
Each
Case of 10
GLS014.202.04
29/32
19/26
Each
Case of 10
GLS014.202.05
29/32
24/29
Each
Case of 10
GLS014.202.06
* 34/35
19/26
Each
Case of 10
GLS014.202.07
* 34/35
24/29
Each
Case of 10
GLS014.202.08
* 34/35
29/32
Each
Case of 10
GLS014.202.09
* 40/38
24/29
Each
Case of 10
GLS014.202.10
* 45/40
29/32
Each
Case of 10
Glassco Swan Neck Adapters, with Screw Thread to Accept Thermometers, etc.
Item Code
Socket Size
Cone Size
Pack Size
Unit
GLS018.202.01
* 14/23
19/26
Each
Each
GLS018.202.01A
* 19/26
19/26
Each
Each
GLS018.202.02
* 19/26
24/29
Each
Each
GLS018.202.03
* 24/29
24/29
Each
Each
GLS018.202.04
* 29/32
29/32
Each
Each
* denotes products not stocked
Item Code
Socket Size
Approx. Length
Pack Size
Unit
GLS019.202.01
* 14/23
65mm
Each
Case of 10
GLS019.202.02
* 19/26
65mm
Each
Case of 10
GLS019.202.03
* 24/29
65mm
Each
Case of 10
GLS019.202.04
* 29/32
65mm
Each
Case of 10
Approx. Length
Pack Size
Unit
Glassco Long Stem Adapters
Item Code
Socket Size
GLS019.202.05
* 14/23
190mm
Each
Case of 10
GLS019.202.06
* 19/26
200mm
Each
Case of 10
GLS019.202.07
* 24/29
200mm
Each
Case of 10
GLS019.202.08
* 29/32
200mm
Each
Case of 10
Volumetric Glassware >> Adapters
Glassco Short Stem Adapters
Glassco Straight Receiver Adapters
Item Code
Socket Size
Pack Size
Unit
GLS020.202.01
* 14/23
Each
Case of 10
GLS020.202.02
* 19/26
Each
Case of 10
GLS020.202.03
* 24/29
Each
Case of 10
GLS020.202.04
* 29/32
Each
Case of 10
77
Interchangeable Glassware
Interchangeable Glassware
Glassco Bend Adapters, with Vacuum Connection and Screw Thread Adapter
Item Code
Socket Size
Cone Size
Pack Size
Unit
GLS022.201.01
* 14/23
14/23
Each
Each
GLS022.201.02
* 14/23
19/26
Each
Each
GLS022.201.03
* 19/26
19/26
Each
Each
GLS022.201.04
* 19/26
24/29
Each
Each
GLS022.201.05
* 24/29
24/29
Each
Each
GLS022.201.06
* 24/29
29/32
Each
Each
GLS022.201.07
* 29/32
29/32
Each
Each
Glassco Straight Adapters, with Vacuum Connection and Screw Thread Adapter
Laboratory Glassware Catalogue 2012/13
Item Code
Cone Size
Pack Size
Unit
GLS022.202.01
* 14/23
14/23
Each
Each
GLS022.202.02
* 14/23
19/26
Each
Each
GLS022.202.02A
* 19/26
19/26
Each
Each
GLS022.202.03
* 19/26
24/29
Each
Each
GLS022.202.04
* 24/29
24/29
Each
Each
GLS022.202.05
* 24/29
29/32
Each
Each
GLS022.202.06
* 29/32
29/32
Each
Each
Glassco Receiver Adapters, with Multiple Connections and Screw Thread
Item Code
78
Socket Size
Socket Size
Cone Size
Pack Size
Unit
GLS024.202.01
* 14/23
14/23
Each
Each
GLS024.202.02
* 14/23
19/26
Each
Each
GLS024.202.03
* 19/26
19/26
Each
Each
* denotes products not stocked
Item Code
Socket Size
Cone Size
Pack Size
Unit
GLS025.202.00
* 14/23
14/23
Each
Each
GLS025.202.0A
* 14/23
19/26
Each
Each
GLS025.202.01
* 19/26
19/26
Each
Each
GLS025.202.02
* 19/26
24/29
Each
Each
GLS025.202.03
* 24/29
24/29
Each
Each
GLS025.202.04
* 29/32
29/32
Each
Each
Cone Size to Fit Condenser
Pack Size
Unit
Glassco Recovery Bends, with Sloping Socket
Item Code
Cone Size to Fit Flask
GLS026.202.01
* 14/23
14/23
Each
Each
GLS026.202.02
* 24/29
14/23
Each
Each
GLS026.202.03
* 19/26
19/26
Each
Each
GLS026.202.04
* 24/29
19/26
Each
Each
GLS026.202.05
* 29/32
19/26
Each
Each
GLS026.202.06
* 29/32
29/32
Each
Each
GLS026.202.07
* 24/29
24/29
Each
Each
GLS026.202.08
* 34/35
24/29
Each
Each
GLS026.202.09
* 29/32
24/29
Each
Each
GLS026.202.10
* 34/35
34/35
Each
Each
Volumetric Glassware >> Adapters
Glassco Plain Bend Receiver Adapters
79
Interchangeable Glassware
Interchangeable Glassware
Glassco Recovery Bends, Vertical
Item Code
Cone Size to Fit Flask
Cone Size to Fit Condenser
Pack Size
Unit
GLS027.202.01
* 14/23
14/23
Each
Each
GLS027.202.02
* 19/26
19/26
Each
Each
GLS027.202.03
* 24/29
24/29
Each
Each
GLS027.202.04
* 24/29
24/29
Each
Each
GLS027.202.05
* 29/32
29/32
Each
Each
Cone Size
Pack Size
Unit
Glassco Splash Heads, Vertical
Laboratory Glassware Catalogue 2012/13
Item Code
80
Socket Size
GLS030.202.01
* 14/23
14/23
Each
Each
GLS030.202.02
* 19/26
24/29
Each
Each
GLS030.202.03
* 29/32
29/32
Each
Each
Cone Size
Pack Size
Unit
Glassco Splash Heads, Vertical, Pear Shaped
Item Code
Socket Size
GLS031.202.01
* 14/23
14/23
Each
Each
GLS031.202.02
* 19/26
19/26
Each
Each
GLS031.202.03
* 24/29
19/26
Each
Each
GLS031.202.04
* 24/29
24/29
Each
Each
GLS031.202.05
* 29/32
19/32
Each
Each
* denotes products not stocked
Item Code
Socket Size
Cone Size
Pack Size
Unit
GLS032.202.01
* 14/23
14/23
Each
Each
GLS032.202.02
* 19/26
19/26
Each
Each
GLS032.202.03
* 24/29
19/26
Each
Each
GLS032.202.04
* 24/29
24/29
Each
Each
GLS032.202.05
* 29/32
29/32
Each
Each
Glassco Adapter Cones, with Stem to Rubber Tubing, Right Angle Connection
Item Code
Cone Size
Pack Size
Unit
GLS036.202.01
14/23
Each
Each
GLS036.202.02
19/26
Each
Each
GLS036.202.03
24/29
Each
Each
GLS036.202.04
* 29/32
Each
Each
Volumetric Glassware >> Adapters
Glassco Splash Heads, Sloping, Pear Shaped
Glassco Adapter Sockets to Rubber Tubing, with Screw Thread
Item Code
GLS038.202.01
Cone Size
* 14/23
Pack Size
Unit
Each
Each
GLS038.202.02
* 19/26
Each
Each
GLS038.202.03
* 24/29
Each
Each
GLS038.202.04
* 29/32
Each
Each
81
Glassco Socket to Cone Adapters, with Side Arm and Screw Thread
Item Code
Socket Size
Cone Size
Pack Size
Unit
GLS039.202.01
* 14/23
14/23
Each
Each
GLS039.202.02
* 14/23
19/26
Each
Each
GLS039.202.03
* 14/23
24/29
Each
Each
GLS039.202.04
* 14/23
29/32
Each
Each
GLS039.202.05
* 19/26
19/26
Each
Each
GLS039.202.06
* 19/26
24/29
Each
Each
GLS039.202.07
* 19/26
29/32
Each
Each
GLS039.202.08
* 24/29
24/29
Each
Each
GLS039.202.09
* 24/29
29/32
Each
Each
GLS039.202.10
* 29/32
29/32
Each
Each
Laboratory Glassware Catalogue 2012/13
Interchangeable Glassware
Interchangeable Glassware
82
* denotes products not stocked
Baskets84
Drying Racks
84
Pipette Teats
84
Bench Protectors
85
Detergents85
Water Stills
86
related products
Related Products
Related Products
Baskets
Met-App Test Tube Baskets, Autoclavable
Item Code
Type
Dimensions (mm)
Pack Size
Unit
MET4015-150
* White nylon coated
150x150x150
Each
Each
MET4015-200
* White nylon coated
200x200x200
Each
Each
MET4017-150
* Stainless steel
150x150x150
Each
Each
MET4017-200
* Stainless steel
200x200x200
Each
Each
Drying Racks
Laboratory Glassware Catalogue 2012/13
Met-App Drying Racks, Autoclavable, White Nylon Coated
Item Code
Mount
Dimensions (mm)
Pack Size
Unit
MET4050
Wall mounted
570x600
Each
Each
MET4055
* Bench mounted
360x500
Each
Each
Pipette Teats
LabServ Rubber Teats, for use with Pasteur Pipettes and Glass Droppers
84
Item Code
Colour
Pack Size
Unit
LBS444260
Red
10pcs
Each
* denotes products not stocked
Related Products >> Sub-Section
Bench Protectors
Benchkote™ is an absorbent, impermeable material designed to protect laboratory
surfaces against hazardous spills. The material features a high-quality, smooth,
absorbent Whatman paper which quickly absorbs liquid spills, and a laminated
polyethylene layer that prevents flow-through to the working surface. After use the
sheet is incinerated or disposed of according to local regulations.
Whatman Benchkote™
Item Code
Type
Dimensions
Pack Size
Unit
WHA2300-916
Sheets
460x570mm
50pcs
Each
WHA2300-599
* Pad
460x570mm
50pcs
Each
WHA2300-731
Reel
460mmx50m
Each
Each
WHA2300-772
* Reel
920mmx50m
Each
Each
Type
Size
Pack Size
Unit
Decon 90 liquid concentrate
Detergents
Decon Detergents
Item Code
DEC90-5L
5L
Each
Case of 4
DECACIDRINSE
* Acid rinse liquid
5L
Each
Each
DECDECMATIC-5L
* Decomatic liquid
5L
Case of 4
Case of 4
Each
Case of 4
DECDRI-DECN-5KG
Dri-decon granular concentrate 5kg
85
Related Products
Related Products
Water Stills
• The Merit is the ideal choice for budget conscious laboratories that can’t afford to
compromise on quality
• It combines economy and high performance with a host of other features which
comparable stills cannot match
• Glass construction with long life metal heating element
• Two independent safety thermostats
• Wall mountable
• Output: 4 litres/hour, single distilled
Laboratory Glassware Catalogue 2012/13
Stuart Merit Water Still
Item Code
Type
Pack Size
Unit
BIBW4000
Water Still Merit
Each
Each
Available in New Zealand Only
The metal still cases are attractively finished in a durable powder coating.
Each still maybe wall, shelf or bench mounted. The still monitors the water
level in any reservoir to which you connect it, and controls the operation
of the still, turning it on and off as the water level changes in the reservoir.
Together with over-temperature and feed water supply failure protection,
this allows 24-hour unattended operation of all stills.
Labglass Water Stills
Item Code
Type
Output
Feed
Pack Size
Unit
LABRG1
* Cascade
3L/hr
Single
Each
Each
LABRG2
* Cascade
3L/hr
Dual
Each
Each
LABRG3
* Delta
3-6L/hr
Single
Each
Each
Available in Australia Only
86
* denotes products not stocked
technical data
Technical Data
Technical Data
Glassco NABL Accreditation
Glassco’s Calibration Laboratory has undertaken accreditation for its
system for calibration and testing as per ISO 17025:2005.
Results of calibration are guaranteed for precision as per the DIN, ISO, USP
& ASTM standards.
Glassco’s Calibration Laboratory is NABL approved. NABL has an MRA
under the Asia Pacific Laboratory Accreditation Cooperation (APLAC) and
the International Laboratory Accreditation Cooperation (ILAC), which means
the calibration provided to customers for volumetric ware is acceptable in
calibration laboratories worldwide.
The calibrations performed by Glassco calibration laboratory are conducted
under ISO 17025:2005.
Laboratory Glassware Catalogue 2012/13
Care and Use — Cleaning Methods
Care should be exercised when using most cleaning solutions as they can
cause skin irritations or severe burns on contact. Dilute solutions become
concentrated as the water evaporates; therefore, always flush the exposed
area immediately with large quantities of water.
NOTE: If wiping or other mechanical cleaning action is necessary, it should
be done gently using non-abrasive cleaners and wiping materials. The use
of abrasive materials will damage the glass surface, degrading its inherent
strength.
The list of methods given here is by no means complete, but offers a fairly
wide variety and should cover all the usual contaminants, as well as the
more important special cases.
There are some specific contaminants that may require specialised
cleaning methods, and some are given here:
1. Permanganate stains. Use a mixture of equal volume of 3% sulfuric acid
and 3% hydrogen peroxide.
2. Iron stains. Use a solution containing one part hydrochloric acid and one
part water.
3. Bacteriological material. Glassware should be soaked in a suitable
disinfectant solution or steam autoclaved followed by cleaning with a
suitable agent.
It is frequently desirable to give glassware a preliminary rinse or soak with
an organic solvent to remove grease, followed by a water rinse. The rinsing
with water must be done thoroughly if acid will be used later to clean the
glassware.
Unless autoclaving is necessary, glassware should be cleaned as soon
as possible after use to avoid setting and caking of residues. Pipettes, for
example, may be placed in a convenient jar containing a weak antiseptic
solution immediately after use. Autoclaving is necessary to disinfect
glassware that may have been used to contain potentially dangerous
biological fluids.
There is a wide variety of cleaning agents available that will remove
surface contaminants such as silicone and other organic and biological
residues that may interfere with trace analyses. These cleaners
are available in biodegradable, phosphate-free and chromium-free
formulations if desired, and can be obtained from Thermo Fisher Scientific.
88
CAUTIONS: Before using any cleaning solution, refer to its Material
Safety Data Sheet for precautions to be observed during use. Some of
the cleaning materials used may leave trace residue unless the rinsing
process is carried out thoroughly. While such traces may not be harmful
if the object of cleaning is to prepare the glassware for calibration, they
can give trouble in certain laboratory operations. When glassware is to
be calibrated, the final rinsings must be performed with distilled water.
If an article is to be dried after cleaning, as is necessary for all vessels
marked “To Contain”, ethyl alcohol or acetone (American Chemical Society
Specification) may be used. Drying may be hastened by blowing clean, dry
air into the vessel (or sucking the air through the vessel). Efficient air filters
must be provided to remove any particles.
You play by common, ordinary, everyday rules, the kinds of things you’d do
naturally if you just took time to think about them:
1. Don’t get cut – it hurts you and your productivity.
2. Don’t drop glassware – avoid the bruises that lead to breakage.
3. Don’t use chipped or broken glassware – it’s dangerous and breaks
more readily.
4. Don’t mouth pipette – you could inhale a toxic substance, burn your
mouth, or cut your lip.
5. Don’t leave pipettes sticking out of beakers or flasks – an invitation for
an accident.
6. Insert tubing carefully. Use a protective towel for your hand and lubricate
the tubing.
7. Dispose of broken glassware in a special receptacle.
8. Carry large containers carefully, using a bottle carrier.
9. Clean and rinse glassware very well with deionised water, then let it
drain dry on a clean, lint-free towel.
To back up the rules, you need a formal laboratory safety program. It
begins with a written safety policy, a safety committee, and regular safety
inspections. That way, you can investigate accidents thoroughly, keep a
record and analysis of them, and promote safety awareness all the time. It
could lead you to the best safety record ever.
Technical Data >> Glassware
Glassware Safety
Care and Use — Cleanliness of Apparatus
The usual criterion of cleanliness of glass apparatus is uniform wetting
of the surface by distilled water. Certain contaminants, especially grease,
adhering to the walls prevent them from being uniformly wetted, and there
is a tendency for water to collect into drops.
Imperfect wetting causes irregularities in capacity of volumetric glassware
by distorting the meniscus, and also by affecting the volume of the residue
adhering to the walls after emptying instruments calibrated to deliver the
indicated volume.
Even when the surface of the vessel is uniformly wetted, variations in
the apparent capacity still may occur, due to contamination of the liquid
surface by minute quantities of fatty or other organic substances which
produce a change in surface tension affecting the shape of the meniscus.
The cleaning, rinsing and drying, therefore, must be carried out in such a
way as to prevent this from happening.
The choice of the procedure to be used in cleaning glassware depends on
the nature of the contaminant. In many cases special reagents or methods
must be used to remove a particular substance. Before listing the more
important methods, it is desirable to make a few general statements.
Glass
Glasses used in chemical apparatus have excellent resistance to acids,
except hydrofluoric. Strong alkaline solutions, such as hot caustic
solutions, will attack any glass if contact is prolonged. This is true even
though a particular glass may not exhibit any visible effect, due to the
solubility of the reaction products. Dilute detergent solutions, up to about
2% strength, will have no serious effect on the glass, unless the glass is
exposed for unnecessarily long periods or the detergent is allowed to dry
on the glass.
Coloured Graduations
The scales and inscriptions of many items of Kimble glassware are
coloured by staining a thin layer of the glass. Since the coloured portion
is of the same composition as the glass object, the resistance to chemical
attack is the same as that of the rest of the glass. Here, the colour can
be removed only by dissolving a layer of glass from the surface. Some
Kimble volumetric glassware has fused on, ceramic enamel printed lines
and inscriptions. These fused-on enamels are quite resistant to acids and
alkalies. In most cases they should last as long as the piece of apparatus if
cared for properly. However, by their nature, they cannot be as resistant as
the ware to which they adhere. Consequently, the graduated lines should
not be subjected to prolonged immersion in acids or alkalies. Whenever
the lines are wetted by reagents, they should be rinsed as soon as
conveniently possible.
Safety Precautions
With many pieces of glassware, it is necessary or desirable to fill by
suction when cleaning. Do not suck up acid or other cleaners by mouth.
In fact, do not pipette by mouth at all. Use hand held, manual or electronic
pipetting aids
89
Technical Data
Technical Data
Abrasives
Do not use abrasives on glassware, particularly volumetric ware. The
surface will be marred in time, and the resultant scratches may prevent
proper drainage or act as resting places for adulterants which will be
difficult to remove.
Water for Rinsing
When preparing a piece of glassware for calibration, rinsing with tap water
should be followed by a thorough rinsing with distilled water. Sufficient
material may be deposited on the surface by tap water to cause erratic
results, particularly with small items, even though water wets the surface
uniformly. Even in ordinary cleaning processes, the use of deionised water
is recommended.
Adherent Organic Residues
Never attempt to remove such residues by the application of direct heat.
Permanent strains may be introduced and, what is more important, the
calibration of volumetric apparatus may be changed.
Care and Use — Ground-Glass Surfaces
Laboratory Glassware Catalogue 2012/13
Ground-glass joints and stopcocks should never be used when dry.
Although ground-glass surfaces seal well without the use of lubricants, it
is advisable to lubricate them to prevent sticking and breakage. Ground
surfaces must be cleaned prior to lubrication—dust, dirt and particulate
90
matter may score the surface and cause leakage.
Different lubricants are used for these operating conditions:
Silicone grease—for high temperature and high vacuum
Glycerin—for long term reflux or extraction
Hydrocarbon grease—for general laboratory use
Lubricating Ground-Glass Joints
1. Lubricate joints that must be airtight and when glassware contains
strong alkaline solutions.
2. Lubricate only the upper part of the inner joint. A properly lubricated
joint appears clear, without striations.
3. Do not allow grease to come in contact with vapour or liquid and cause
contamination.
Lubricating Stopcocks
Spread two circular bands of grease around the stopcock plug. Insert
the plug into the barrel and twist several times until the assembly is
completely transparent. Be careful not to use too much lubricant or the
bore will become plugged.
Recommendations for the Care and Use of Glassware
A. TO AVOID SERIOUS AND PERSONAL INJURY, AVOID ABRASIONS
An abrasion reduces the strength of glass, making it more susceptible to
breakage under impact and/or thermal shock. Thermal shock may result
from sudden changes in temperature or use on either a burner or hot
plate. Serious injuries could result if breakage occurs while glass holds
heated and/or corrosive liquid.
B. RECOMMENDED GLASSWARE CLEANING AND HANDLING
PROCEDURES
Proper Cleaning Procedure
1. Washing machines may be used. Support racks on the washer must be
well maintained. The support pins should be coated with a nonabrasive
material to prevent metal to glass contact and scratching.
2. For manual washing, use only plastic core brushes that have soft
nonabrasive bristles. Soft, clean sponges or other wiping materials may
be used. DO NOT USE THESE BRUSHES OR WIPING MATERIALS WITH
ABRASIVE CLEANERS. Keep them clean. Scotch Brite and similar scouring
pads will scratch glass and should not be used.
3. Inspect glassware before each use and discard if scratched, chipped,
cracked or damaged in any way.
4. Many commercial glass cleaners are available. Follow the
manufacturer’s directions for the use of these products since some are
corrosive and can damage the glass.
5. Organic solvents are acceptable cleaning agents when conditions
warrant their use.
possible injury.
C. AVOID IMPACT
Glass will break as a result of impact. Use care when handling to avoid
impacting hard objects, such as spigots, other glassware, counter tops,
etc.
D. HEATING GLASSWARE
1. Use wire gauze when heating over open flame.
2. Use either low or medium heat settings when using a hot plate. High hot
plate settings will cause excessive localised heating of the glassware and
will eventually cause breakage and possible injury.
3. Do not heat glassware designated as heavy duty unless recommended
by the manufacturer. Even though these items have added mechanical
strength, they are more susceptible to breakage from thermal shock when
heated.
4. Do not allow the contents of the container to boil dry as this may
induce permanent stresses that will eventually cause breakage. Discard
containers that have been boiled dry.
DO NOT evacuate or pressurise unless recommended.
E. CENTRIFUGE TUBES
RCF values can be significantly reduced if the glass tubes have been
scratched or otherwise physically abused resulting in surface damage and
lowered glass strength.
Technical Data >> Glassware
Improper Cleaning Procedure:
1. Do not place metal or other hard objects, such as spatulas, glass stirring
rods, or brushes with metal parts, inside the glassware. This will scratch
the glass and cause eventual breakage and injury.
2. Do not use strong alkaline products and hydrofluoric acid as cleaning
agents; they are glass dissolvers and can damage the glassware and
eventually cause breakage which can result in injury.
3. Do not use any abrasive cleansers, including soft cleansers (i.e. Ajax,
Comet, Old Dutch, Soft Scrub, etc.), as these will scratch the glass and
cause eventual breakage and injury.
4. Do not place hands inside glassware while wearing any jewellery,
particularly diamond rings, as these will score the inside of the glassware
and eventually cause breakage and injury.
5. Do not heat glassware to temperatures (>426˚C) needed to burn out
carbon residues. This will result in the introduction of permanent stresses
in the glass that will eventually cause the glassware to break resulting in
Recommendations for the Care and Use of NMR Tubes
A. TO AVOID SERIOUS AND PERSONAL INJURY, AVOID ABRASIONS AND
IMPACTS
Abrasions reduce the strength of glass, making it more susceptible to
breakage under impact and/or thermal shock. Thermal shock may result
from sudden changes in temperature or use on either a burner or hot
plate. Serious injuries could result if breakage occurs while glass holds
heated and/or corrosive liquid. Glass will break as a result of impact. Use
care when handling to avoid impacting hard objects, such as spigots,
other glassware, counter tops, etc.
B. RECOMMENDED GLASSWARE CLEANING AND HANDLING
EQUIPMENT AND PROCEDURES
Proper Cleaning Procedure
1. Kimble Chase offers several styles of NMR tube washers:
KON897033-0003 5-place 3mm Tube Washer
KON897033-0005 5-place 5mm Tube Washer
KON897030-0005 Single-place 5mm Tube Washer
KON459960-0000 Single-place 10mm Tube, Cuvette, and Cell Washer
2. Before use, rinse or clean the tube with distilled water and dry properly.
3. Empty and rinse reusable tubes as soon as possible after use. Always
properly discard disposable NMR tubes as soon as possible after use.
4. Use of a fume hood is recommended when cleaning NMR tubes.
Popular cleaning solutions include acetone, distilled water, and methanol
or ethyl alcohol, as well as organic solvents. Difficult cleaning jobs may
require the use of mineral acid or fuming nitric acid soaks. Final rinses of
distilled water or acetone are recommended depending on the intended
use.
5. After cleaning, properly dry by air or with a nitrogen gas stream.
6. Inspect tubes before each use and discard if scratched, chipped,
cracked or damaged in any way.
7. Clean the outside of the tube in order to prevent introduction of dirt or
impurities to the probe or the internal mechanisms of the NMR machine.
8. Always store NMR tubes in dry, particle free environments.
Improper Cleaning Procedure and Use:
1. Never use chromic acid, or any caustic or alkaline solutions with an
NMR tube.
2. Never dry tubes in an oven for more than 30 minutes at 125ºC.
3. Never store tubes in an oven. Excessive heat can cause warpage.
4. Never use any tube that does not roll evenly on flat surfaces, or exhibits
any physical abnormality.
91
Laboratory Glassware Catalogue 2012/13
Technical Data
Technical Data
Care and Handling of Volumetric Glassware
“To Contain ” versus “To Deliver”
Proper use of calibrated volumetric glassware requires that the user be
informed whether the ware is a “to contain” or “to deliver” vessel. All
Kimble calibrated ware is marked either “TC” or “TD”. When the graduation
line denotes the volume contained in the calibrated vessel, the ware is
marked “TC”. When the graduation line indicates the volume delivered
from the vessel, the ware is marked “TD”. When a vessel is calibrated
“TD”, it differs from a “TC” calibrated vessel in that a drainage holdback
error, the amount of water required to wet the inner surface of the vessel
in contact with the water, is added to the “TC” volume. The “TD” vessel
then delivers the same volume as contained in a “TC” vessel. Product
descriptions in this catalog usually state the method of calibration used.
(The International Standards Organization designation for “to contain” is
“IN” and “to deliver”, is “EX”.)
Pipettes Calibrated “To Deliver” (EX)
The pipette is clamped in a vertical position and the 3-way stopcock
connected to it with rubber tubing. The bent arm of the stopcock has
a length of rubber hose attached which can be held in the mouth or
connected to a vacuum line. Distilled water at the temperature of the room
is placed in the large beaker. The water is stirred before use, care being
taken not to introduce air into it. Before making a weighing, the pipette is
filled one or more times from the beaker by applying suction through the
stopcock, in order to bring the pipette to the temperature of the water.
Finally the pipette is filled to about 10 mm above the mark, the stopcock
closed, and the beaker removed.
The stopcock now is opened to connect the pipette to the straight vertical
tube and the water lowered slowly to the 0 line. During this emptying, the
edge of the tip is kept in contact with the side of the beaker. The rate of
descent of the water is controlled by a finger applied to the upper end of
this tube. After setting to 0, the stopcock is closed. Then the temperature
of the water in the large beaker is taken and this reading is used as the
temperature of the water in the pipette. All deliveries should start at the 0
line.
To start the delivery into the receiver the stopcock is opened fully, again
connecting pipette and vertical tube. The plug is not touched after this, any
control needed being exercised by the forefinger on the vertical tube. The
same precautions are taken as for burettes against splashing of water and
wetting the upper part of the neck of the receiver.
92
Where delivery of a measuring or serological pipette is very rapid, the
forefinger must be held on the vertical tube from the start of delivery, but
water is retarded as little as possible without losing control. For weighings
of intermediate lines, water is allowed to empty until a few mm above
the line. Then a finger on the vertical tube is used to slow up the delivery
so that the water can be set accurately at the mark. The tip is kept in
constant contact with the receiving vessel throughout the delivery. Then
the receiver is withdrawn and the stopcock closed. When the pipette has
an opaque ring or rings near the top, this indicates that the amount of
water remaining in the tip after free delivery has ceased is to be blown out
and added to the original delivery. A count of two seconds is made after
free delivery has ended and while the neck and tip are still in contact, then
air is blown through the rubber hose on the bent arm of the stopcock to
eject the liquid in the tip. The neck of the bottle is removed from contact
immediately after this. Give only one puff, strong enough to expel the
liquid. The time of two seconds has been selected as being the average
length of time required in actual service after free delivery has ceased to
insert the top of the pipette in the mouth preparatory to blowing through.
Pipettes Calibrated “To Contain” (IN)
If the capacity is from a mark to the tip, the pipette should be weighed dry,
filled with water to the mark and reweighed. To hold the pipette a saddle
may be used on the balance pan. The pipette may be set up as explained
previously and the filling and setting to the mark accomplished in the same
way. Then, a rubber cap or a piece of rubber tubing closed by a short
glass rod is slipped up over the tip and the pipette is removed from the
stand and weighed. The first weighing of the dry pipette should include the
rubber cap or rubber tubing.
When the indicated volume is between marks, the pipette is filled
completely up to the top mark, weighed, dried and then filled up to bottom
mark and weighed. The difference in weight is the apparent weight of the
water contained between the two marks. In this case the weight of the
empty pipette is not needed.
Flasks and Cylinders Calibrated “To Contain” (IN)
Flasks and cylinders calibrated to contain are cleaned, dried and weighed
empty, filled accurately and weighed again. The difference between the
two weights, of course, is the apparent weight of the volume contained.
Flasks and Cylinders Calibrated “To Deliver” (EX)
If flasks and cylinders calibrated to deliver are to be calibrated, it will be
FILLING AND EMPTYING
The results obtained with volumetric apparatus depend not only on the
accuracy with which the ware is calibrated, but also on the method of use.
Insofar as possible, users should manipulate the instruments in exactly the
same way as the manufacturer does when locating the calibration lines.
The instructions given here apply particularly to apparatus used with a
liquid which wets the glass and must be followed in every respect to obtain
the most accurate results when such apparatus is to be calibrated. Since
mercury does not wet glass, the factors of importance are cleanliness,
the use of an ascending meniscus when possible, and the tapping of the
vessel before reading the meniscus.
The following rules have been suggested by the National Bureau of
Standards. (These requirements may seem at times to be unduly detailed,
but they are based on exact knowledge of the behavior of the various types
of apparatus as determined experimentally.)
Burettes
Burettes should be held in a vertical position and filled to about 10 mm
above the 0 line. Any liquid on the outside of the tip is removed at this
time with clean filter paper. The setting to the 0 line is made by slowly
emptying the excess liquid into a beaker or other receptacle with the side
touching the edge of the tip. Any liquid remaining at the tip after setting
has been made is touched-off against the wet side of the receptacle.
When delivery is started, stopcocks should be completely open, even
though it is necessary to slow the delivery near the end of a titration. If an
exact quantity is desired, the liquid is slowed down when it is about 10
mm above the final line in order to set the meniscus accurately at this line.
As soon as delivery has been completed the tip is touched to the side of
the receiver and the latter removed from contact. Measurements made
in laboratories with burettes ordinarily are from the 0 mark. Other initial
points may be used on precision apparatus without serious error, but this
is not advised with burets having very rapid delivery.
Technical Data >> Glassware
found best to weigh the filled piece first, empty it and weigh again. The
second weight includes the film remaining on the walls after delivery. In
all cases, the top of the flask or cylinder should be closed by a cap of
some type to minimise evaporation losses. Care must also be taken in
handling not to deposit moisture or grease from the hands on the surface
of the glass. Therefore, the actual contact with the glass should be by
means of a clean cloth, gloves or secure holding device. The entire neck
of a flask is wetted by the distilled water and a drainage time of about 2
minutes allowed before completing the setting. To fill a cylinder, the water
is allowed to run down one side only, although the entire wall is wetted for
about 10 mm above the line to be calibrated by rotation or slightly tipping
in several directions. A drainage time of about 2 minutes is allowed before
the final adjustment is made. For the final adjustment, a pipette or dropper
with a finely drawn point should be used. The temperature of the water
can be taken in the filled piece just after the weighing has been completed
unless the volume is small. In the latter case, if the thermometer happens
to be at a different temperature, the reading obtained may be in error due
to the effect of the comparatively large bulk of the thermometer in heating
or cooling the water. The alternative is to fill the flask from a reservoir and
use the temperature of the water in the reservoir. To calibrate centrifuge
tubes, Babcock test bottles and similar articles by weighing the water
contained, use the methods outlined for flasks and cylinders, except that
the wall is wetted above the line being checked only far enough to insure a
correctly shaped meniscus.
Cylinders
In filling a cylinder the liquid is allowed to flow down one side only.
However, the entire wall is wetted for about 10 mm above the meniscus,
by a gentle rotation of the cylinder or, preferably, by tipping it slightly in
several directions. Here, a drainage time of about 2 minutes is allowed
before completing the setting. The delivery of the contents of a cylinder is
accomplished in the same way as described for a flask.
(NOTE: These directions apply when highly accurate deliveries are wanted.
In ordinary laboratory work where measurements are of approximate
volumes only, no special precautions in filling and emptying cylinders
are necessary.) You should bear in mind, however, that the accuracy you
achieve is dependent on your method. Good method, consistently applied,
will yield good results. Poor or sloppy methods will yield poor results.
Flasks
When a solution is made up to a definite strength in a volumetric flask, the
entire neck usually is wet at the time the volume is adjusted, due to the
mixing process. Consequently, in filling flasks the entire neck is wetted by
the distilled water. A drainage time of about 2 minutes is allowed before
completing the setting.
If a flask is calibrated to deliver its indicated capacity, the delivery is made
by gradually inclining the flask, avoiding, as much as possible, agitation of
the contents and sloshing around of the liquid. The process should take
half a minute. At the end of the emptying the instrument should be nearly
vertical and should be held so for another half minute. Then the drop
adhering to the lip should be touched off against the wet surface of the
receiving vessel.
Pipettes
Pipettes also are held in a vertical position and filled to about 10 mm
93
Technical Data
Technical Data
above the 0 line. The technique of setting to this line is the same as
used for burettes. The rate of outflow at this point is controlled by slight
pressure of the forefinger on the top. With MEASURING and SEROLOGICAL
PIPETTES, delivery is unrestricted, unless the liquid descends so rapidly
that it would be impossible to stop at the desired place. In this case,
however, delivery should be as fast as possible while retaining control
with a finger. The tip is touched to the side of the receiver when delivery
is completed and then removed immediately, except for certain types of
serological pipette. These are “calibrated for blowout”, i.e., to deliver the
indicated capacity when the small amount remaining in the tip after free
delivery has ceased is blown out (with tip in contact with the wet side of
the receiver, if possible) and added to the initial volume. As mentioned
before, all blowout pipettes are marked with either a wide opaque ring, two
narrower opaque rings near the top, or two printed rings near the top.
(NOTE: With measuring pipettes of small capacity, there may be a tendency
for free delivery to cease before the liquid reaches the lowest graduation
lines. If this is so, the tip should be kept in contact with the receiving vessel
during the delivery, and not just to touch off the last drop when delivery is
finished.)
VOLUMETRIC PIPETTES are held in a vertical position and outflow is
unrestricted. The tip is touched to the wet surface of the receiving vessel and
kept in contact with it until the water has ceased to flow. A count of two is
made and the tip then withdrawn horizontally from contact with the receiver.
The water remaining in the tip is not blown out, except in the case of Ostwald
pipette used in biochemical work. These pipettes are usually “calibrated for
blowout” and are marked also with an opaque ring near the top.
Laboratory Glassware Catalogue 2012/13
Physical Properties of Glass
94
Glass is an inorganic product of fusion that has cooled to a rigid condition
without crystallising and, therefore, has no melting point as such. There
are, however, four temperatures that are of interest to the glassblower.
They are:
1. The Working Point — the temperature at which glass has a viscosity
of 104 poises. At this temperature, glass is soft enough for most
lampworking or sealing operations.
2. The Softening Point — the temperature at which glass has a
viscosity of 107.6 poises. In this temperature range glass will deform
noticeably under its own weight: ASTM C 338.
3. The Annealing Point — the temperature at which the internal stress
caused by rapid cooling from lampworking or forming temperatures
may be substantially removed in a matter of minutes. It is determined
by measuring the elongation rate versus temperature of a fiber of glass
under conditions prescribed by ASTM Designation C 336. The values
given herein are typical for production glasses.
4. The Strain Point — the temperature at which the internal strain in
a glass is substantially relieved only after a matter of hours and not
at a commercially desirable rate. It is determined by extrapolation of
annealing point data for fiber elongation: ASTM C 336.
Physical Properties of KG-33 and N-51A Glasses
KG-33
N-51A
Working Point
1255°C
1140°C
Strain Point
513°C
530°C
Annealing Point
565°C
570°C
Softening Point
827°C
785°C
Linear Coefficient of Expansion (from 0 to 300°C), in./in./°C
32x10-755x10-7
Density grams per cm3
2.22
2.33
Refractive Index—Sodium D line (.5893 microns)
1.47
1.49
Visible Light Transmission, 2 mm thickness
92%
91%
Specific Heat (in g. cals per g. deg.)
0.204 (25 to 175°C)
Thermal Conductivity (in cals/cm/cm2/sec/°C)
0.0027
Technical Data >> Glassware
Table 2
0.204
(25 to 175°C)
0.0026
95
Technical Data
Technical Data
Ground Ware
Standard Taper Symbol
Spherical Joint Symbol
is the symbol used to designate “standard taper” interchangeable
joints, stoppers and stopcocks, complying with the requirements of ASTM
E675 for stopcocks, stoppers and reagent bottle necks and E676 for
interchangeable joints. All mating parts are finished to a 1:10 taper.
is the designation for “spherical (semi-ball) joints” complying with ASTM
E677.
Laboratory Glassware Catalogue 2012/13
The size of a particular piece appears after the appropriate symbol. Due
primarily to the greater variety of apparatus equipped with fittings, a
number of different types of identifications are used, as follows:
96
Apparatus and Bottles
• For joints - a two part number, as 24/40, with 24 being the
approximate diameter in mm at the large end of the taper, and 40
the axial length of taper, also in mm.
• For bottles - a single number, as 19, with 19 being the
approximate diameter in mm of the opening at top of neck.
• For glass stopcocks - a single number, as 2, with 2 being the
approximate diameter in mm of the bore or bores through the plug.
Flasks
• For volumetric and Erlenmeyer flasks, graduated cylinders, etc.
a single number as 19, with 19 again being the approximate
diameter in mm at top of neck; however, there are differences
in dimensions between the bottle and flask stoppers, see the
individuals listings in this catalogue.
The complete designation of a spherical joint also consists of a two part
number, as 12/2, with 12 being the approximate diameter in mm of the
ball and 2 the bore in mm of the ball and the socket.
Product Standard Symbol
is the symbol used to designate “product standard” compliance. Kimble
glass stop­cocks with plugs made of PTFE meet the requirements of
ASTM Specification E911. The symbol is used to designate that Kimble
stopcocks comply with this standard. All mating parts are finished to a 1:5
taper.
Finally, for the PTFE plug ware, a single number is used, as with
stopcocks. Thus, 2 means a stopcock with a bore of approximately 2
mm in the plug.
* denotes products not stocked
Technical Data >> Ground Ware
97
Technical Data
Technical Data
Ground Ware
Laboratory Glassware Catalogue 2012/13
(
Computed
Computed
Diameter
Diameter
at at
Standard
Standard
Approximate
Approximate
Approximate
Approximate
Large
Large
EndEnd
of of
Joint
Joint
SizeSizeDiameter
Diameter
at at Length
Length
of of Ground
Ground
Zone
Zone
Number
Number Small
Small
EndEndGround
Ground
Zone
Zone
(Gauging
(Gauging
Point)
Point)
( Designation)mmmm
Designation)
mmmm
mmmm
(
Computed
Computed
Diameter
Diameter
at at
Standard
Standard Approximate
ApproximateApproximate
ApproximateLarge
Large
EndEnd
of of
Joint
Joint
SizeSize Diameter
Diameter
at at Length
Length
of of Ground
Ground
Zone
Zone
Number
Number Small
Small
EndEnd Ground
Ground
Zone
Zone
(Gauging
(Gauging
Point)
Point)
( Designation) mmmm
Designation)
mmmm
mmmm
7/25.............
7/25.............
5 5
10/30............
10/30............
7 7
12/30..........
12/30..........9.5 9.5
14/35............
14/35............
11 11
19/38............
19/38............
15 15
25
30
30
35
38
25
30
30
35
38
7.5 7.5
10.010.0
12.512.5
14.514.5
18.818.8
5/125/12
................
................
3.8 3.8
7/157/15
................
................
6.0 6.0
10/18
10/18
................
................
8.2 8.2
12/18
12/18
...............10.7
...............10.7
14/20
14/20
...............12.5
...............12.5
12
15
18
18
20
12
15
18
18
20
5.0 5.0
7.5 7.5
10.010.0
12.512.5
14.514.5
24/40............
24/40............
20 20
29/42............
29/42............
25 25
34/45............
34/45............
30 30
40/50............
40/50............
35 35
45/50............
45/50............
40 40
40
42
45
50
50
40
42
45
50
50
24.024.0
29.229.2
34.534.5
40.040.0
45.045.0
19/22
19/22
...............16.6
...............16.6
24/25
24/25
...............21.5
...............21.5
29/26
29/26
...............26.6
...............26.6
34/28
34/28
...............31.7
...............31.7
40/35
40/35
...............36.5
...............36.5
22
25
26
28
35
22
25
26
28
35
18.818.8
24.024.0
29.229.2
34.534.5
40.040.0
50/50............
50/50............
45 45
55/50............
55/50............
50 50
60/50............
60/50............
55 55
71/60............
71/60............
65 65
103/60
103/60
...........
...........
97 97
50
50
50
60
60
50
50
50
60
60
50.050.0
55.055.0
60.060.0
71.071.0
103.0
103.0
Standard
Dimensions
Short-length
Interchangeable
Standard
Dimensions
for for
Short-length
Interchangeable
Taper-Ground
Joints
Taper-Ground
Joints
(
98
Standard
Standard
Dimensions
Dimensions
for for
Medium-length
Medium-length
Interchangeable
Taper-Ground
Joints
Interchangeable
Taper-Ground
Joints
Standard
Standard
Dimensions
Dimensions
for for
Full-length
Full-length
Interchangeable
Interchangeable
Taper-Ground
Joints
Taper-Ground
Joints
Computed
Computed
Diameter
Diameter
at at
Standard
Standard
Approximate
Approximate
Approximate
Approximate
Large
Large
EndEnd
of of
Joint
Joint
SizeSizeDiameter
Diameter
at at Length
Length
of of Ground
Ground
Zone
Zone
Number
Number Small
Small
EndEndGround
Ground
Zone
Zone
(Gauging
(Gauging
Point)
Point)
( Designation)mmmm
Designation)
mmmm
mmmm
Standard
Dimensions
for for
Interchangeable
Standard
Dimensions
Interchangeable
Spherical-Ground
Joints
Spherical-Ground
Joints
Standard
Standard
Joint
Joint
SizeSize Nominal
Nominal
Number
Number
Diameter
Diameter
( Designation)
( Designation) mmmm
Nominal
Nominal
Tube
Tube
Gauging
Gauging
BallBall
Diameter
Diameter
Diameter
Diameter
I.D. I.D.
mmmm
inches
inches
5/8.............
5/8.............
4.2 4.2
7/10............
7/10............
6.5 6.5
10/710/7
............
............
9.3 9.3
10/10
10/10
...........
...........
9.0 9.0
12/10
12/10
...........11.5
...........11.5
14/10
14/10
...........13.5
...........13.5
8
10
7
10
10
10
8
10
7
10
10
10
5.0 5.0
7.5 7.5
10.010.0
10.010.0
12.512.5
14.514.5
7/1 7/1
.................
.................
7 7
12/112/1
...............
...............
12 12
12/1.5
12/1.5
............
............
12 12
12/212/2
...............
...............
12 12
12/312/3
...............
...............
12 12
12/512/5
...............
...............
12 12
1 1
1 1
1.5 1.5
2 2
3 3
5 5
19/10
19/10
...........17.8
...........17.8
10 10
18.818.8
18/718/7
...............
...............
18 18
7 7
.28125
.28125
± .00005
± .00005
.5000
.5000
± .0001
± .0001
.5000
.5000
± .0001
± .0001
.5000
.5000
± .0001
± .0001
.5000
.5000
± .0001
± .0001
.5000
.5000
± .0001
± .0001
* denotes products not stocked
.7500
.7500
± .0001
± .0001
42 42
45 45
50 50
50 50
29.2
29.2
34.5
34.5
40.0
40.0
45.0
45.0
50/50............
45 45
50/50............
55/50............
50 50
55/50............
60/50............
55 55
60/50............
71/60............
65 65
71/60............
103/60
...........
97 97
103/60
...........
50 50
50 50
50 50
60 60
60 60
50.0
50.0
55.0
55.0
60.0
60.0
71.0
71.0
103.0
103.0
Standard
Dimensions
forfor
Short-length
Interchangeable
Standard
Dimensions
Short-length
Interchangeable
Taper-Ground
Joints
Taper-Ground
Joints
(
Computed
Computed
Diameter
at at
Diameter
Standard
Approximate
Large
EndEnd
of of
StandardApproximate
Approximate
Approximate
Large
Joint
SizeSizeDiameter
at at Length
of of Ground
Zone
Joint
Diameter
Length
Ground
Zone
Number
EndEndGround
Zone
(Gauging
Point)
Number Small
Small
Ground
Zone
(Gauging
Point)
Designation)
mmmm
mmmm
( Designation)mmmm
24/25
...............21.5
24/25
...............21.5
29/26
...............26.6
29/26
...............26.6
34/28
...............31.7
34/28
...............31.7
40/35
...............36.5
40/35
...............36.5
25 25
26 26
28 28
35 35
24.0
24.0
29.2
29.2
34.5
34.5
40.0
40.0
Standard
Dimensions
forfor
Interchangeable
Standard
Dimensions
Interchangeable
Spherical-Ground
Joints
Spherical-Ground
Joints
Standard
Standard
Joint
SizeSize
Nominal
Joint
Nominal
Number
Diameter
Number
Diameter
( Designation)
( Designation) mmmm
Nominal
Nominal
Tube
Gauging
BallBall
Tube
Gauging
Diameter
Diameter
Diameter
Diameter
I.D. I.D.
mmmm
inches
inches
5/8.............
4.24.2
5/8.............
7/10............
6.56.5
7/10............
10/7
............
9.39.3
10/7
............
10/10
...........
9.09.0
10/10
...........
12/10
...........11.5
12/10
...........11.5
14/10
...........13.5
14/10
...........13.5
8 8
10 10
7 7
10 10
10 10
10 10
5.05.0
7.57.5
10.0
10.0
10.0
10.0
12.5
12.5
14.5
14.5
7/17/1
.................
7 7
.................
12/1
...............
12 12
12/1
...............
12/1.5
............
12 12
12/1.5
............
12/2
...............
12 12
12/2
...............
12/3
...............
12 12
12/3
...............
12/5
...............
12 12
12/5
...............
1 1
1 1
1.51.5
2 2
3 3
5 5
19/10
...........17.8
19/10
...........17.8
24/12
...........22.8
24/12
...........22.8
29/12
...........28.0
29/12
...........28.0
34/12
...........33.3
34/12
...........33.3
40/12
...........38.8
40/12
...........38.8
10 10
12 12
12 12
12 12
12 12
18.8
18.8
24.0
24.0
29.2
29.2
34.5
34.5
40.0
40.0
18/7
...............
18 18
18/7
...............
18/9
...............
18 18
18/9
...............
28/12
.............
28 28
28/12
.............
28/15
.............
28 28
28/15
.............
35/20
.............
35 35
35/20
.............
7 7 .7500
± .0001
.7500
± .0001
9 9 .7500
± .0001
.7500
± .0001
12 12 1.1250
± .00015
1.1250
± .00015
15 15 1.1250
± .00015
1.1250
± .00015
20 20 1.3750
± .00015
1.3750
± .00015
45/12
...........43.8
45/12
...........43.8
50/12
...........48.8
50/12
...........48.8
55/12
...........53.8
55/12
...........53.8
60/12
...........58.8
60/12
...........58.8
71/15
...........69.5
71/15
...........69.5
12 12
12 12
12 12
12 12
15 15
45.0
45.0
50.0
50.0
55.0
55.0
60.0
60.0
71.0
71.0
35/25
.............
35 35
35/25
.............
40/25
.............
40 40
40/25
.............
50/30
.............
50 50
50/30
.............
65/40
.............
65 65
65/40
.............
75/50
.............
75 75
75/50
.............
102/75
...........102
102/75
...........102
25 25
25 25
30 30
40 40
50 50
75 75
.28125
± .00005
.28125
± .00005
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
.5000
± .0001
Technical Data >> Ground Ware
29/42............
25 25
29/42............
34/45............
30 30
34/45............
40/50............
35 35
40/50............
45/50............
40 40
45/50............
1.3750
± .00015
1.3750
± .00015
1.6500
± .00015
1.6500
± .00015
2.0000
± .00015
2.0000
± .00015
2.5000
± .0002
2.5000
± .0002
3.0000
± .00025
3.0000
± .00025
4.0000
± .0003
4.0000
± .0003
99
Thermo Fisher Scientific is committed to working with you to increase
efficiency, giving you the freedom to focus on your research. Our goal is
to help you succeed. However you measure success, we can provide the
resources and the programs to help you achieve it. By choosing Thermo
Fisher, you have selected a partner with over a century of experience.
Australia: For customer service, call 1300-735-292
Visit us online at: www.thermofisher.com.au
New Zealand: For customer service, call 0800-933-966
Visit us online at: www.thermofisher.co.nz
1338168170-01-0512-GRP
©2012
Thermo
Fisher
Scientific
rights reserved.
©
2012 Thermo
Fisher
Scientific
Inc. AllInc.
rightsAllreserved.
Specifications, terms & pricing are subject to change.
Not all products are available in all countries. Please consult your local sales representative for details.