76 C ARTRI DG E H OU S I NG S VAC U U M F I LTRATION Acr ylic Cartridge Housing – 1PA Type • • • • Acrylic housing for a single cartridge filter, with 3/4" PF type inlet and outlet; high quality and economical Transparent housing permits observation of filtration process Lightweight yet strong construction; can be assembled by hand Designed for use with end fixture codes C and F S P E C I F I C AT I O N S Model Cartridge Capacity Cartridge Compatibility Inlet/Outlet Dimensions Height (mm) Diameter Max. Operation Temperature Max. Operation Pressure Composition Weight (kg) 1PA 250 mm x 1 End fixture codes: C and F 3 /4 " PF (3/4 "PFM x 3/4 " PTM changeable) 345 170 38°C 0.5 MPa (73 psi) @ 38°C Head: Polypropylene Body: Acrylonitrile Styrene Resin (acrylic) Body O-ring: Silicone Connector O-ring:NBR 1.0 Note: - 1PA Type units are made for aqueous filtration only and are not suitable for air or organic solvent filtration. - 1PA Type units cannot be sterilized by autoclave. - Units include hand-tightening tool as standard accessory. - Use thread-sealing tape on tapered inlet and outlet. 1PA Head Plug O R D E R I N G I N F O R M AT I O N Model Catalog No. Plug O-ring Head 1PA 26807000 OUT Introduction Glass Microfiltration: Support Systems 13 mm Glass Microanalysis Holders 25 mm Glass Microanalysis Holders 47 mm Glass Microanalysis Holders 47 mm Glass Microanalysis Holders – With All-PTFE Seal 47 mm Glass Sterility Test Unit 90 mm Glass Microanalysis Holders Filter Flasks and Stoppers All-Glass Filtration Assemblies Phase/Fraction Collectors Stainless Steel Filter Holders Polysulfone Filter Holders PVC Standard Vacuum Manifolds PVC Extraction Manifolds Stainless Steel Vacuum Manifolds Vacuum Pressure Pumps 78 79 80 81 82 83 84 85 86 87 88 89 90 92 93 94 96 Connector Connector O-ring OPTIONAL ACCESSORIES Adapter IN Adapter O-ring Sealing O-ring Housing Body Model ø15mm Hose Adapter L-shape Mounting Kit Housing Stand Composition Polypropylene SUS304 SUS304 Catalog No. 28801011 28801022 28801012 Plug O-ring Drain Plug 800-334-7132 800-334-7132 78 VAC U U M F I LTRATION VAC U U M F I LTRATION Introduction Glass Microfiltration: Support Systems Vacuum filtration is used primarily in microbiological and analytical procedures that involve collecting a particulate (bacteria, precipitate, etc.) from a liquid suspension. Liquid poured into a funnel passes through a filter, which retains the particulate, and filtrate can be collected into a filter flask, directly or via a vacuum manifold. Applying vacuum reduces process time compared to gravity flow. Typical Applications DNA/RNA hybridization, protein binding, receptor binding studies and gravimetric analysis Advantec supplies a wide range of vacuum filter holders and accessories. Select from glass, polysulfone, or stainless steel assemblies with funnels holding from 15 to 1000 mL. See facing page for more details on supports. Sintered Glass Support (Glass Frit) • • • Glass frit (nominal retention 30-50 microns) Recommended when filtering highly acidic (low pH) solutions or when slower flow rates are preferred to maximize contact with the filter or reagent Ground glass seal Diameter Coliform, yeast, mold, total bacteria, sterility testing Colony hybridization, procedures requiring larger filtration area KG 47 KGS 47 KG 90 KGS 90 13 25 47 90 mm mm mm mm 13/100 mL 311100 - 15 mL 311200 - 100 mL 311000 311480 - Funnel Size 150 mL 311280 - 300 mL 311290 311400 - 500 mL 311050 311490 - 500 mL 311590 - 1000 mL 315110 352200 1000 mL 311110 314110 352100 Recommended Models Glass with glass frit Glass with stainless steel support Glass with PTFE support Glass with all-PTFE seal All-glass assembly Phase/Fraction collector Polysulfone Stainless steel Membrane diameter Filtration area * See individual models for exceptions. KG 13 - KG 25 KGS 25 - GFA 25 GFS 25 - - 25 mm 1.2 cm2 Filter Specifications 25 mm 2.1 cm2 KGT 47 KGT 47 TF GFA 47 GFS 47 GFT 47 P/FC 1 P/FC 2 KP 47 KSF 47 - 47 mm 9.6 cm2 * 90 mm 43.2 cm2 - Stainless Steel Support • • • • • Stainless steel screen (Type 316, 100 mesh) PTFE gasket Maximize flow rate with proteinaceous or viscous solutions Will not shed particles into the filtrate Ground glass seal Diameter - 25 mm 47 mm 90 mm - 15 mL 311300 - 100 mL 311580 - Funnel Size 150 mL 300 mL 311380 311390 311500 - PTFE Support • • • • PTFE support (0.05 inch / 1.3 mm diameter holes) Filter acidic solutions at a higher flow rate PTFE support is interchangeable with stainless steel support Ground glass seal Diameter 47 mm 100 mL 311680 Funnel Size 300 mL 500 mL 311540 311690 1000 mL 316110 Glass frit, stainless steel support, PTFE support All-PTFE Seal • • All-PTFE seal prevents sticking and tearing that can occur when membrane is autoclaved in place in a ground glass assembly PTFE flange seals to PTFE coated funnel Diameter 47 mm Support PTFE Stainless Steel Funnel, 300 mL 351620 351600 All PTFE seal 800-334-7132 w w w. a d v a n t e c m f s . c o m 79 78 VAC U U M F I LTRATION VAC U U M F I LTRATION Introduction Glass Microfiltration: Support Systems Vacuum filtration is used primarily in microbiological and analytical procedures that involve collecting a particulate (bacteria, precipitate, etc.) from a liquid suspension. Liquid poured into a funnel passes through a filter, which retains the particulate, and filtrate can be collected into a filter flask, directly or via a vacuum manifold. Applying vacuum reduces process time compared to gravity flow. Typical Applications DNA/RNA hybridization, protein binding, receptor binding studies and gravimetric analysis Advantec supplies a wide range of vacuum filter holders and accessories. Select from glass, polysulfone, or stainless steel assemblies with funnels holding from 15 to 1000 mL. See facing page for more details on supports. Sintered Glass Support (Glass Frit) • • • Glass frit (nominal retention 30-50 microns) Recommended when filtering highly acidic (low pH) solutions or when slower flow rates are preferred to maximize contact with the filter or reagent Ground glass seal Diameter Coliform, yeast, mold, total bacteria, sterility testing Colony hybridization, procedures requiring larger filtration area KG 47 KGS 47 KG 90 KGS 90 13 25 47 90 mm mm mm mm 13/100 mL 311100 - 15 mL 311200 - 100 mL 311000 311480 - Funnel Size 150 mL 311280 - 300 mL 311290 311400 - 500 mL 311050 311490 - 500 mL 311590 - 1000 mL 315110 352200 1000 mL 311110 314110 352100 Recommended Models Glass with glass frit Glass with stainless steel support Glass with PTFE support Glass with all-PTFE seal All-glass assembly Phase/Fraction collector Polysulfone Stainless steel Membrane diameter Filtration area * See individual models for exceptions. KG 13 - KG 25 KGS 25 - GFA 25 GFS 25 - - 25 mm 1.2 cm2 Filter Specifications 25 mm 2.1 cm2 KGT 47 KGT 47 TF GFA 47 GFS 47 GFT 47 P/FC 1 P/FC 2 KP 47 KSF 47 - 47 mm 9.6 cm2 * 90 mm 43.2 cm2 - Stainless Steel Support • • • • • Stainless steel screen (Type 316, 100 mesh) PTFE gasket Maximize flow rate with proteinaceous or viscous solutions Will not shed particles into the filtrate Ground glass seal Diameter - 25 mm 47 mm 90 mm - 15 mL 311300 - 100 mL 311580 - Funnel Size 150 mL 300 mL 311380 311390 311500 - PTFE Support • • • • PTFE support (0.05 inch / 1.3 mm diameter holes) Filter acidic solutions at a higher flow rate PTFE support is interchangeable with stainless steel support Ground glass seal Diameter 47 mm 100 mL 311680 Funnel Size 300 mL 500 mL 311540 311690 1000 mL 316110 Glass frit, stainless steel support, PTFE support All-PTFE Seal • • All-PTFE seal prevents sticking and tearing that can occur when membrane is autoclaved in place in a ground glass assembly PTFE flange seals to PTFE coated funnel Diameter 47 mm Support PTFE Stainless Steel Funnel, 300 mL 351620 351600 All PTFE seal 800-334-7132 w w w. a d v a n t e c m f s . c o m 79 80 VAC U U M F I LTRATION VAC U U M F I LTRATION 13 mm Glass Microanalysis Holders 25 mm Glass Microanalysis Holders of liquid Concentrate samples in a small area (1.2 cm2) KG 13 AA features a two-part funnel (13 mL/100 mL) connected by a ground glass joint KG 13 available in three different funnel sizes for biological or particulate contamination Available with sintered glass or stainless steel support Use stainless steel screen when producing ultraclean filtrate or when filtering proteinaceous solutions • Filter small volumes • Use for filtering small volumes • • • • • S P E C I F I C AT I O N S S P E C I F I C AT I O N S KG 25 Materials: Support Funnel, base Stopper Clamp Connection: Included Sintered glass Borosilicate glass Silicone rubber Anodized aluminum KG 13 A (311000) KG 13 AA (311100) #5 stopper adapts to standard 125 mL vacuum filter flask Optional #8b stopper adapts to 1 L flask or standard manifold Pressure: Weight: Membrane Filter Compatibility: Vacuum 0.37 kg (0.88 lb) Filter size Prefilter size 25 mm Not Recommended Filtration area 1.2 cm2 100 mL KG 13 A 311000 Glass frit support 1000 mL KG 13 C 311110 13/100 mL KG 13 AA 311100 Replacement Parts 1 1 1 1a 2 3 4 5 5 Funnel, Funnel, Funnel, Funnel, 100 mL 500 mL 1000 mL 100 mL with 14/20 Male Sintered glass Stainless steel screen Borosilicate glass Silicone rubber Anodized aluminum #5 stopper adapts to standard 125 mL vacuum filter flask #8b stopper adapts to 1 L flask or standard manifold Vacuum 0.19 kg (0.45 lb) 311001 311005 311010 311101 Microfunnel (13/100 mL) Clamp Base (glass frit) 311105 311003 311002 Stopper, #5 Stopper, #8B 311004 311008 150 mL and 300 mL funnels for 25 mm holders are available in complete assemblies or as accessory parts. 25 mm 16 mm 2.1 cm2 Funnel capacity 500 mL KG 13 B 311050 KGS 25 O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Funnel capacity Model Catalog No. Materials: Support Funnel, base Stopper Clamp Connection: Included Optional Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area Stainless steel support 500 mL and 1 L funnels for 13 mm holders are available in complete assemblies or as accessory parts. Model Catalog No. Model Catalog No. 1 1 1 2 3 1a 3 4 5 6 6 2 150 mL KG 25 A 311280 KGS 25 A 311380 300 mL KG 25 B 311290 KGS 25 B 311390 KG 25 (311200) Replacement Parts KG 25 1 15 mL KG 25 311200 KGS 25 311300 Funnel, 15 mL Funnel, 150 mL Funnel, 300 mL Clamp Screen (stainless steel) Gasket (PTFE) Base Stopper, #5 Stopper, #8b KGS 25 311201 311208 311209 311003 311304 311305 311202 311302 311004 311008 1 1 2 3 3 4 4 2 4 5 5 5 5 KG 13 _ KG 13 AA (311100) 6 6 KG 25 (311200) 800-334-7132 KGS 25 (311390) w w w. a d v a n t e c m f s . c o m 81 80 VAC U U M F I LTRATION VAC U U M F I LTRATION 13 mm Glass Microanalysis Holders 25 mm Glass Microanalysis Holders of liquid Concentrate samples in a small area (1.2 cm2) KG 13 AA features a two-part funnel (13 mL/100 mL) connected by a ground glass joint KG 13 available in three different funnel sizes for biological or particulate contamination Available with sintered glass or stainless steel support Use stainless steel screen when producing ultraclean filtrate or when filtering proteinaceous solutions • Filter small volumes • Use for filtering small volumes • • • • • S P E C I F I C AT I O N S S P E C I F I C AT I O N S KG 25 Materials: Support Funnel, base Stopper Clamp Connection: Included Sintered glass Borosilicate glass Silicone rubber Anodized aluminum KG 13 A (311000) KG 13 AA (311100) #5 stopper adapts to standard 125 mL vacuum filter flask Optional #8b stopper adapts to 1 L flask or standard manifold Pressure: Weight: Membrane Filter Compatibility: Vacuum 0.37 kg (0.88 lb) Filter size Prefilter size 25 mm Not Recommended Filtration area 1.2 cm2 100 mL KG 13 A 311000 Glass frit support 1000 mL KG 13 C 311110 13/100 mL KG 13 AA 311100 Replacement Parts 1 1 1 1a 2 3 4 5 5 Funnel, Funnel, Funnel, Funnel, 100 mL 500 mL 1000 mL 100 mL with 14/20 Male Sintered glass Stainless steel screen Borosilicate glass Silicone rubber Anodized aluminum #5 stopper adapts to standard 125 mL vacuum filter flask #8b stopper adapts to 1 L flask or standard manifold Vacuum 0.19 kg (0.45 lb) 311001 311005 311010 311101 Microfunnel (13/100 mL) Clamp Base (glass frit) 311105 311003 311002 Stopper, #5 Stopper, #8B 311004 311008 150 mL and 300 mL funnels for 25 mm holders are available in complete assemblies or as accessory parts. 25 mm 16 mm 2.1 cm2 Funnel capacity 500 mL KG 13 B 311050 KGS 25 O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Funnel capacity Model Catalog No. Materials: Support Funnel, base Stopper Clamp Connection: Included Optional Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area Stainless steel support 500 mL and 1 L funnels for 13 mm holders are available in complete assemblies or as accessory parts. Model Catalog No. Model Catalog No. 1 1 1 2 3 1a 3 4 5 6 6 2 150 mL KG 25 A 311280 KGS 25 A 311380 300 mL KG 25 B 311290 KGS 25 B 311390 KG 25 (311200) Replacement Parts KG 25 1 15 mL KG 25 311200 KGS 25 311300 Funnel, 15 mL Funnel, 150 mL Funnel, 300 mL Clamp Screen (stainless steel) Gasket (PTFE) Base Stopper, #5 Stopper, #8b KGS 25 311201 311208 311209 311003 311304 311305 311202 311302 311004 311008 1 1 2 3 3 4 4 2 4 5 5 5 5 KG 13 _ KG 13 AA (311100) 6 6 KG 25 (311200) 800-334-7132 KGS 25 (311390) w w w. a d v a n t e c m f s . c o m 81 82 VAC U U M F I LTRATION VAC U U M F I LTRATION 47 mm Glass Microanalysis Holders 47 mm Glass Microanalysis Holders – With All-PTFE Seal for microbiology and particulate analysis Filter up to 1000 mL Available with sintered glass, stainless steel, or PTFE support • Standard size • • • Filter sealed between PTFE surfaces: – – S P E C I F I C AT I O N S Materials: Support Funnel, base Stopper Clamp Connections (included): KG 47 KGS 47 KGT 47 Sintered glass Stainless steel screen PTFE S P E C I F I C AT I O N S As for corresponding basic model (Page 82) with the addition of PTFE coating on bottom of funnel and PTFE flange for KGS 47 TF and KGT 47 TF. O R D E R I N G I N F O R M AT I O N Borosilicate glass Silicone rubber Anodized aluminum #8 stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup Funnel capacity Glass frit support 47mm Glass Microanalysis Holder Vacuum 0.6 kg (1.2 lb) Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area Stainless Steel Support PTFE Support Model KG 47 KGS 47 KGT 47 300 mL KG 47 TF 311600 Model Catalog No. Model Catalog No. KGS 47 TF 351600 KGT 47 TF 351620 All PTFE seal Replacement Parts KG 47 TF 1 2 3 3 4 5 6 Funnel Capacity Support Type Glass Frit Support Model Catalog No. 1 O R D E R I N G I N F O R M AT I O N 300 mL 311400 311500 311540 Stainless steel support PTFE support 47 mm 35 mm 9.6 cm2 100 mL A 311480 311580 311680 Bottom of funnel is coated with PTFE PTFE flange covers contact surface on glass base (except for glass frit base) 500 mL B 311490 311590 311690 1000 mL C 314110 315110 316110 2 3 3a 4 Funnel coated with PTFE, 300 mL Clamp Screen (stainless steel) PTFE support Flange (PTFE) Base Stopper, #8 311402 KGS 47 TF KGT 47T F 351601 311403 311504 311604 351603 351603 311602 311404 5 Replacement Parts KG 47 1 1 1 1 2 3a 3b 4 5 6 - Funnel, 100 mL Funnel, 300 mL Funnel, 500 mL Funnel, 1000 mL Clamp Screen (stainless steel) PTFE support Gasket (PTFE) Base Stopper, #8 Optional extension (2") 311402 KGS 47 311408 311401 311409 311410 311403 311504 - KGT 47 1 1 6 KGS 47 (311500) 311604 311505 311502 311404 - 2 2 3 3b 4 1 311450 5 5 2 5 311450 The 2 inch extension provides physical separation of the two filters that set up in series. 800-334-7132 6 6 KGT 47 (311540) 6 KG 47 (311400) KGS 47 TF (351600) KGT 47 TF (351620) KG 47 TF (311600) w w w. a d v a n t e c m f s . c o m 83 82 VAC U U M F I LTRATION VAC U U M F I LTRATION 47 mm Glass Microanalysis Holders 47 mm Glass Microanalysis Holders – With All-PTFE Seal for microbiology and particulate analysis Filter up to 1000 mL Available with sintered glass, stainless steel, or PTFE support • Standard size • • • Filter sealed between PTFE surfaces: – – S P E C I F I C AT I O N S Materials: Support Funnel, base Stopper Clamp Connections (included): KG 47 KGS 47 KGT 47 Sintered glass Stainless steel screen PTFE S P E C I F I C AT I O N S As for corresponding basic model (Page 82) with the addition of PTFE coating on bottom of funnel and PTFE flange for KGS 47 TF and KGT 47 TF. O R D E R I N G I N F O R M AT I O N Borosilicate glass Silicone rubber Anodized aluminum #8 stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup Funnel capacity Glass frit support 47mm Glass Microanalysis Holder Vacuum 0.6 kg (1.2 lb) Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area Stainless Steel Support PTFE Support Model KG 47 KGS 47 KGT 47 300 mL KG 47 TF 311600 Model Catalog No. Model Catalog No. KGS 47 TF 351600 KGT 47 TF 351620 All PTFE seal Replacement Parts KG 47 TF 1 2 3 3 4 5 6 Funnel Capacity Support Type Glass Frit Support Model Catalog No. 1 O R D E R I N G I N F O R M AT I O N 300 mL 311400 311500 311540 Stainless steel support PTFE support 47 mm 35 mm 9.6 cm2 100 mL A 311480 311580 311680 Bottom of funnel is coated with PTFE PTFE flange covers contact surface on glass base (except for glass frit base) 500 mL B 311490 311590 311690 1000 mL C 314110 315110 316110 2 3 3a 4 Funnel coated with PTFE, 300 mL Clamp Screen (stainless steel) PTFE support Flange (PTFE) Base Stopper, #8 311402 KGS 47 TF KGT 47T F 351601 311403 311504 311604 351603 351603 311602 311404 5 Replacement Parts KG 47 1 1 1 1 2 3a 3b 4 5 6 - Funnel, 100 mL Funnel, 300 mL Funnel, 500 mL Funnel, 1000 mL Clamp Screen (stainless steel) PTFE support Gasket (PTFE) Base Stopper, #8 Optional extension (2") 311402 KGS 47 311408 311401 311409 311410 311403 311504 - KGT 47 1 1 6 KGS 47 (311500) 311604 311505 311502 311404 - 2 2 3 3b 4 1 311450 5 5 2 5 311450 The 2 inch extension provides physical separation of the two filters that set up in series. 800-334-7132 6 6 KGT 47 (311540) 6 KG 47 (311400) KGS 47 TF (351600) KGT 47 TF (351620) KG 47 TF (311600) w w w. a d v a n t e c m f s . c o m 83 84 VAC U U M F I LTRATION VAC U U M F I LTRATION 47 mm Glass Microanalysis Holder – Sterility Test Unit • Complete filter assembly for sterility testing 90 mm Glass Microanalysis Holders of antibiotics and pharmaceuticals • • Use with the sterility test manifold (Page 94) • Available with sintered glass or stainless steel support S P E C I F I C AT I O N S As for corresponding basic model (Page 82) with additional components as listed below. S P E C I F I C AT I O N S KG 90 Materials: Support Funnel, base Stopper Clamp Connection (Included): O R D E R I N G I N F O R M AT I O N Funnel capacity Model Catalog No. area for filtering larger volumes (> 500 ml) Use for viscous samples or those with a heavy particle or bioburden that would clog a 47 mm filter • Larger filtration 300 mL STU 1A 314100 Replacement Parts 1 Funnel, 300 mL 311401 2 Clamp 311403 3 Base (glass frit) 311402 4 #8 Stopper 311404 5 Stopcock 313902 6 Silicone tubing 53 cm (21") 1/4"ID, 3/8"OD 313903 7 KS 13 filter holder* 301000 8 Injector needle 313901 9 Silicone cover 313904 * 13 mm Hydrophobic PTFE membrane filter is recommended (Page 11). Sintered glass Stainless steel screen Borosilicate glass Silicone rubber Anodized aluminum #8 stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup Vacuum 1.2 kg (2.82 lb) Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area Sterility test unit KGS 90 KG 90 (352100) 90 mm 70 mm 43 cm2 O R D E R I N G I N F O R M AT I O N Funnel capacity 5 Glass frit support Stainless steel support 7 KG 90 KGS 90 1000 mL graduated (1100 mL max.) 352100 352200 1 1 8 Replacement Parts 9 KG 90 1 6 2 1 2 3 5 6 Funnel, 1000 mL Clamp Screen (stainless steel) Base #8 Stopper - KGS 90 352101 352103 352204 352102 352202 311404 2 2 3 5 5 3 4 6 6 KG 90 (352100) KGS 90 (352200) STU 1A (314100) 800-334-7132 w w w. a d v a n t e c m f s . c o m 85 84 VAC U U M F I LTRATION VAC U U M F I LTRATION 47 mm Glass Microanalysis Holder – Sterility Test Unit • Complete filter assembly for sterility testing 90 mm Glass Microanalysis Holders of antibiotics and pharmaceuticals • • Use with the sterility test manifold (Page 94) • Available with sintered glass or stainless steel support S P E C I F I C AT I O N S As for corresponding basic model (Page 82) with additional components as listed below. S P E C I F I C AT I O N S KG 90 Materials: Support Funnel, base Stopper Clamp Connection (Included): O R D E R I N G I N F O R M AT I O N Funnel capacity Model Catalog No. area for filtering larger volumes (> 500 ml) Use for viscous samples or those with a heavy particle or bioburden that would clog a 47 mm filter • Larger filtration 300 mL STU 1A 314100 Replacement Parts 1 Funnel, 300 mL 311401 2 Clamp 311403 3 Base (glass frit) 311402 4 #8 Stopper 311404 5 Stopcock 313902 6 Silicone tubing 53 cm (21") 1/4"ID, 3/8"OD 313903 7 KS 13 filter holder* 301000 8 Injector needle 313901 9 Silicone cover 313904 * 13 mm Hydrophobic PTFE membrane filter is recommended (Page 11). Sintered glass Stainless steel screen Borosilicate glass Silicone rubber Anodized aluminum #8 stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup Vacuum 1.2 kg (2.82 lb) Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area Sterility test unit KGS 90 KG 90 (352100) 90 mm 70 mm 43 cm2 O R D E R I N G I N F O R M AT I O N Funnel capacity 5 Glass frit support Stainless steel support 7 KG 90 KGS 90 1000 mL graduated (1100 mL max.) 352100 352200 1 1 8 Replacement Parts 9 KG 90 1 6 2 1 2 3 5 6 Funnel, 1000 mL Clamp Screen (stainless steel) Base #8 Stopper - KGS 90 352101 352103 352204 352102 352202 311404 2 2 3 5 5 3 4 6 6 KG 90 (352100) KGS 90 (352200) STU 1A (314100) 800-334-7132 w w w. a d v a n t e c m f s . c o m 85 86 VAC U U M F I LTRATION Filter Flasks and Stoppers • • • • • • All-Glass Filtration Assemblies Borosilicate filter flasks and silicone rubber stoppers are compatible with Advantec filter holders Use flasks to collect filtrate or to act as a trap to prevent liquid from damaging pump or vacuum line #5 and #8b stoppers adapt 13 mm, 25 mm and KP 47 filter holders to 125 mL (#5) and 1 L (#8b) flasks #8 stopper adapts 47 mm (except KP 47) and 90 mm filter holders to the 1 L flask Side arm connection 3/8" Flasks with ground glass joint fit holders with female joint (GFA, P/FC 2) Volume 125 mL 1L 250 mL Opening Fits #5 stopper Fits #8 stopper 19/22 male joint (ground glass) Catalog No. 311230 311430 311225 1L 2L 40/35 male joint (ground glass) 40/35 male joint (ground glass) 311425 311426 Size #5 #8b #8 Catalog No. 311004 311008 311404 restricts contact with reactive surfaces such as steel or rubber to minimize contamination of sample or filtrate Standard 25 and 47 mm filtration funnels mount on filtration flask using a ground glass joint Outlet of support base drip tube is positioned below the side arm connection to prevent sample aspiration into vacuum line All wetted surfaces are borosilicate glass with the exception of stainless steel and PTFE support options • All-glass design • • • S P E C I F I C AT I O N S 25 mm Holder Borosilicate Glass Filter Flasks Silicone Rubber Stoppers 87 VAC U U M F I LTRATION Flasks and stoppers compatible with Advantec filter holders Materials: Funnel, base unit and flask Support 47 mm Holder Borosilicate glass Sintered glass, stainless steel screen, or PTFE Connections: Ground glass joint Side arm Capacity: Funnel Receiver flask Membrane filter size Prefilter size (if used with membrane) Filtration area 14/20 female 6 mm (19/22 inch) 40/35 female 6 mm (3/8 inch) 15 mL 250 mL 25 mm 16 mm 2.1 cm2 300 mL 1L 47 mm 35 mm 9.6 cm2 GFA 25 (311220) O R D E R I N G I N F O R M AT I O N 25 mm Holder Support type: Glass frit Stainless steel PTFE Catalog No. 311220 311320 - Model GFA 25 GFS 25 - 47 mm Holder Model GFA 47 GFS 47 GFT 47 Catalog No. 311420 311520 311620 Replacement Parts 25 mm Holder Model Catalog No. 1 Funnel Support PTFE Gasket 4 Support base 5 Clamp 6 Receiver flask 1 47 mm Holder GFA 25 GFS 25 311220 311320 311201 GFA 47 311420 GFS 47 311520 311401 311222 311422 311504 311604 311505 311522 311304 311305 311322 311003 311225 GFT 47 311620 5 4 311403 311425 6 Optional Accessories Funnel, 100 mL Funnel, 150 mL Funnel, 300 mL Funnel, 500 mL beveled Funnel, 1 L graduated Receiver flask, 2 L 800-334-7132 25 mm Holder 47 mm Holder 311408 311208 311209 311409 311410 311426 - GFA w w w. a d v a n t e c m f s . c o m 86 VAC U U M F I LTRATION Filter Flasks and Stoppers • • • • • • All-Glass Filtration Assemblies Borosilicate filter flasks and silicone rubber stoppers are compatible with Advantec filter holders Use flasks to collect filtrate or to act as a trap to prevent liquid from damaging pump or vacuum line #5 and #8b stoppers adapt 13 mm, 25 mm and KP 47 filter holders to 125 mL (#5) and 1 L (#8b) flasks #8 stopper adapts 47 mm (except KP 47) and 90 mm filter holders to the 1 L flask Side arm connection 3/8" Flasks with ground glass joint fit holders with female joint (GFA, P/FC 2) Volume 125 mL 1L 250 mL Opening Fits #5 stopper Fits #8 stopper 19/22 male joint (ground glass) Catalog No. 311230 311430 311225 1L 2L 40/35 male joint (ground glass) 40/35 male joint (ground glass) 311425 311426 Size #5 #8b #8 Catalog No. 311004 311008 311404 restricts contact with reactive surfaces such as steel or rubber to minimize contamination of sample or filtrate Standard 25 and 47 mm filtration funnels mount on filtration flask using a ground glass joint Outlet of support base drip tube is positioned below the side arm connection to prevent sample aspiration into vacuum line All wetted surfaces are borosilicate glass with the exception of stainless steel and PTFE support options • All-glass design • • • S P E C I F I C AT I O N S 25 mm Holder Borosilicate Glass Filter Flasks Silicone Rubber Stoppers 87 VAC U U M F I LTRATION Flasks and stoppers compatible with Advantec filter holders Materials: Funnel, base unit and flask Support 47 mm Holder Borosilicate glass Sintered glass, stainless steel screen, or PTFE Connections: Ground glass joint Side arm Capacity: Funnel Receiver flask Membrane filter size Prefilter size (if used with membrane) Filtration area 14/20 female 6 mm (19/22 inch) 40/35 female 6 mm (3/8 inch) 15 mL 250 mL 25 mm 16 mm 2.1 cm2 300 mL 1L 47 mm 35 mm 9.6 cm2 GFA 25 (311220) O R D E R I N G I N F O R M AT I O N 25 mm Holder Support type: Glass frit Stainless steel PTFE Catalog No. 311220 311320 - Model GFA 25 GFS 25 - 47 mm Holder Model GFA 47 GFS 47 GFT 47 Catalog No. 311420 311520 311620 Replacement Parts 25 mm Holder Model Catalog No. 1 Funnel Support PTFE Gasket 4 Support base 5 Clamp 6 Receiver flask 1 47 mm Holder GFA 25 GFS 25 311220 311320 311201 GFA 47 311420 GFS 47 311520 311401 311222 311422 311504 311604 311505 311522 311304 311305 311322 311003 311225 GFT 47 311620 5 4 311403 311425 6 Optional Accessories Funnel, 100 mL Funnel, 150 mL Funnel, 300 mL Funnel, 500 mL beveled Funnel, 1 L graduated Receiver flask, 2 L 800-334-7132 25 mm Holder 47 mm Holder 311408 311208 311209 311409 311410 311426 - GFA w w w. a d v a n t e c m f s . c o m 88 VAC U U M F I LTRATION VAC U U M F I LTRATION Phase/Fraction Collectors • Collect aliquots of filtrate Stainless Steel Filter Holders – KSF 47 during the filtration process using the 2-way Y bore PTFE valve of hazardous sample or solvents to atmosphere Collect multiple samples with additional receiver sample tubes Two mounting options: P/FC 1 mounts on standard manifold or 1 L flask using a #8 stopper, P/FC 2 has female 40/35 joint to mount on an extraction manifold (Page 93) or 1 L flask Available with sintered glass, stainless steel, or PTFE support • Prevents venting • • • • • S P E C I F I C AT I O N S KSF 47 Materials: Support Funnel, base Stopper Gasket Connections (included): S P E C I F I C AT I O N S P/FC 1 Materials: Funnel, base unit, and receiver tube Support Connections: Base to outlet Borosilicate glass Sintered glass, stainless steel screen, or PTFE Alternate outlet to receiver tube Capacity: Funnel Membrane Filter Compatibility: Membrane filter size Prefilter size Filtration area ORDERING P/FC 2 #8 Stopper Ground glass joint P/FC 2 (311800) 300 mL 47 mm 35 mm 9.6 cm2 1 1 2 3 3 4 5 6 Funnel Clamp Base assembly – glass frit Base assembly – SS or PTFE support Support – stainless steel screen Support – PTFE PTFE gasket (for stainless support) #8 Stopper Receiver tube Clip 4 1 2 3 4 5 5 P/FC 2 40/35 glass joint 311401 311403 KSF 47 352600 1 Funnel SS support screen PTFE gasket KSF 47 352601 311504 311505 Base #8 Stopper 312602 311404 P/FC 1 311702 311802 311752 311852 2 3 311504 311604 1 4 311505 311404 9.3 cm2 Replacement Parts Replacement Parts P/FC 1 #8 Stopper 47 mm 35 mm 3 6 Model Outlet type KSF 47 (352600) 500 mL Vacuum (21 in Hg recommended) 0.5 kg (1.17 lb) O R D E R I N G I N F O R M AT I O N Model Catalog No. P/FC 2 40/35 glass joint 311800 311850 311860 PTFE #8 stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup Filtration area 2 P/FC 1 #8 Stopper 311700 311750 311760 Type 304 stainless steel screen Type 304 stainless steel Silicone rubber Capacity: Funnel Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size 40/35 ground glass joint I N F O R M AT I O N Model Outlet type Glass frit support Stainless steel support PTFE support may be flame sterilized to sanitize the holder between samplings Set pins and a locking nut on the funnel to help prevent twisting and tearing of the membrane Autoclavable with membrane in place • Nonbreakable stainless steel unit 2 311705 3 311706 5 KSF 47 (352600) 6 5 P/FC 2 800-334-7132 w w w. a d v a n t e c m f s . c o m 89 88 VAC U U M F I LTRATION VAC U U M F I LTRATION Phase/Fraction Collectors • Collect aliquots of filtrate Stainless Steel Filter Holders – KSF 47 during the filtration process using the 2-way Y bore PTFE valve of hazardous sample or solvents to atmosphere Collect multiple samples with additional receiver sample tubes Two mounting options: P/FC 1 mounts on standard manifold or 1 L flask using a #8 stopper, P/FC 2 has female 40/35 joint to mount on an extraction manifold (Page 93) or 1 L flask Available with sintered glass, stainless steel, or PTFE support • Prevents venting • • • • • S P E C I F I C AT I O N S KSF 47 Materials: Support Funnel, base Stopper Gasket Connections (included): S P E C I F I C AT I O N S P/FC 1 Materials: Funnel, base unit, and receiver tube Support Connections: Base to outlet Borosilicate glass Sintered glass, stainless steel screen, or PTFE Alternate outlet to receiver tube Capacity: Funnel Membrane Filter Compatibility: Membrane filter size Prefilter size Filtration area ORDERING P/FC 2 #8 Stopper Ground glass joint P/FC 2 (311800) 300 mL 47 mm 35 mm 9.6 cm2 1 1 2 3 3 4 5 6 Funnel Clamp Base assembly – glass frit Base assembly – SS or PTFE support Support – stainless steel screen Support – PTFE PTFE gasket (for stainless support) #8 Stopper Receiver tube Clip 4 1 2 3 4 5 5 P/FC 2 40/35 glass joint 311401 311403 KSF 47 352600 1 Funnel SS support screen PTFE gasket KSF 47 352601 311504 311505 Base #8 Stopper 312602 311404 P/FC 1 311702 311802 311752 311852 2 3 311504 311604 1 4 311505 311404 9.3 cm2 Replacement Parts Replacement Parts P/FC 1 #8 Stopper 47 mm 35 mm 3 6 Model Outlet type KSF 47 (352600) 500 mL Vacuum (21 in Hg recommended) 0.5 kg (1.17 lb) O R D E R I N G I N F O R M AT I O N Model Catalog No. P/FC 2 40/35 glass joint 311800 311850 311860 PTFE #8 stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup Filtration area 2 P/FC 1 #8 Stopper 311700 311750 311760 Type 304 stainless steel screen Type 304 stainless steel Silicone rubber Capacity: Funnel Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size 40/35 ground glass joint I N F O R M AT I O N Model Outlet type Glass frit support Stainless steel support PTFE support may be flame sterilized to sanitize the holder between samplings Set pins and a locking nut on the funnel to help prevent twisting and tearing of the membrane Autoclavable with membrane in place • Nonbreakable stainless steel unit 2 311705 3 311706 5 KSF 47 (352600) 6 5 P/FC 2 800-334-7132 w w w. a d v a n t e c m f s . c o m 89 90 VAC U U M F I LTRATION VAC U U M F I LTRATION Polysulfone Filter Holders Replacement Parts – Funnel assembly • Can be used aseptically provides sufficient clearance so that the membrane will not twist or tear when the funnel is secured Graduated funnel in 300 mL (standard) or 500 mL (wide mouth) capacities Receiver flask (KP 47 S) is interchangeable with all other models Funnel cover can be vented aseptically using disposable syringe filter (13 J P050AN, see page 15) • Recessed filter support • • • KP 47 U (501030) KP 47 H (501020) KP 47 W (501050) KP 47 S (501000) 1 2 3 4 5 6 7 - S P E C I F I C AT I O N S KP 47 H Materials: Support Funnel and base Receiver flask Stopper, O-rings Caps Vacuum adapter Connection: Outlet Receiving flask port Funnel cover port Capacity: Funnel Receiver Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area KP 47 U KP 47 W Polysulfone 8 9 Model Receiver cover Receiver adapter O-ring KP 47 S 501005 501009 Silicone rubber Polypropylene 10 11 12 Vacuum adapter Receiver adapter Receiver O-ring 501013 501007 501015 13 Receiver flask 501006 - Silicone rubber Silicone rubber - - #8b stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup; KP 47 S screws onto receiver flask - Luer slip 300 mL 0.15 Kg (0.33 lb.) KP47KIT - KP 47 S 501000 501010 501001 501002 KP47KIT - Replacement Parts – Receiver flask - - KP 47 H KP 47 U KP 47 W 501020 501030 501050 501010 501001 501002 501102 501008 501004 501003 311008 KP 47 S Polypropylene Polysulfone - Model Catalog No. Gum rubber cap (1) Funnel cover Funnel Funnel O-ring Filter support Base #8b Stopper Cap and filter kit: 5 caps (501010) and 1 filter (13JP050AN) - 300 mL 500 mL Vacuum (25 in Hg maximum) 0.16 Kg (0.36 lb.) 0.15 Kg (0.33 lb.) Luer slip Luer slip 300 mL 300 mL 1 2 KP 47 U 3 KP 47 H KP 47 W Optional Accessories 4 9 Funnel O-ring, FPM Receiver adapter O-ring, FPM 501011 501012 12 Receiver O-ring, FPM 501016 5 6 0.26 Kg (0.58 lb.) KP 47 S 9 7 47 mm 41 mm 13.5 cm2 4 10 8 1 11 O R D E R I N G I N F O R M AT I O N Model KP 47 H KP 47 U KP 47 W KP 47 S Description Polysulfone Filter Holder Polysulfone Aseptic Filter Unit Wide Mouth Polysulfone Filter Holder Polysulfone Aseptic Filter System 800-334-7132 Main Components Funnel, base Funnel, base, cover Funnel, base Funnel, base, cover, receiver Catalog No. 501020 501030 501050 501000 12 13 w w w. a d v a n t e c m f s . c o m 91 90 VAC U U M F I LTRATION VAC U U M F I LTRATION Polysulfone Filter Holders Replacement Parts – Funnel assembly • Can be used aseptically provides sufficient clearance so that the membrane will not twist or tear when the funnel is secured Graduated funnel in 300 mL (standard) or 500 mL (wide mouth) capacities Receiver flask (KP 47 S) is interchangeable with all other models Funnel cover can be vented aseptically using disposable syringe filter (13 J P050AN, see page 15) • Recessed filter support • • • KP 47 U (501030) KP 47 H (501020) KP 47 W (501050) KP 47 S (501000) 1 2 3 4 5 6 7 - S P E C I F I C AT I O N S KP 47 H Materials: Support Funnel and base Receiver flask Stopper, O-rings Caps Vacuum adapter Connection: Outlet Receiving flask port Funnel cover port Capacity: Funnel Receiver Pressure: Weight: Membrane Filter Compatibility: Filter size Prefilter size Filtration area KP 47 U KP 47 W Polysulfone 8 9 Model Receiver cover Receiver adapter O-ring KP 47 S 501005 501009 Silicone rubber Polypropylene 10 11 12 Vacuum adapter Receiver adapter Receiver O-ring 501013 501007 501015 13 Receiver flask 501006 - Silicone rubber Silicone rubber - - #8b stopper adapts to standard 1 L vacuum filter flask or vacuum manifold cup; KP 47 S screws onto receiver flask - Luer slip 300 mL 0.15 Kg (0.33 lb.) KP47KIT - KP 47 S 501000 501010 501001 501002 KP47KIT - Replacement Parts – Receiver flask - - KP 47 H KP 47 U KP 47 W 501020 501030 501050 501010 501001 501002 501102 501008 501004 501003 311008 KP 47 S Polypropylene Polysulfone - Model Catalog No. Gum rubber cap (1) Funnel cover Funnel Funnel O-ring Filter support Base #8b Stopper Cap and filter kit: 5 caps (501010) and 1 filter (13JP050AN) - 300 mL 500 mL Vacuum (25 in Hg maximum) 0.16 Kg (0.36 lb.) 0.15 Kg (0.33 lb.) Luer slip Luer slip 300 mL 300 mL 1 2 KP 47 U 3 KP 47 H KP 47 W Optional Accessories 4 9 Funnel O-ring, FPM Receiver adapter O-ring, FPM 501011 501012 12 Receiver O-ring, FPM 501016 5 6 0.26 Kg (0.58 lb.) KP 47 S 9 7 47 mm 41 mm 13.5 cm2 4 10 8 1 11 O R D E R I N G I N F O R M AT I O N Model KP 47 H KP 47 U KP 47 W KP 47 S Description Polysulfone Filter Holder Polysulfone Aseptic Filter Unit Wide Mouth Polysulfone Filter Holder Polysulfone Aseptic Filter System 800-334-7132 Main Components Funnel, base Funnel, base, cover Funnel, base Funnel, base, cover, receiver Catalog No. 501020 501030 501050 501000 12 13 w w w. a d v a n t e c m f s . c o m 91 92 VAC U U M F I LTRATION PVC Vacuum Manifold – Standard Cup PVC Extraction Manifold – Exterior Taper • Lightweight • Exterior taper • Resistant to acids • accepts a #8 and #8b stopper to adapt microanalysis units and other devices 2-way valve with PTFE stopcock in PVC body Not autoclavable • Standard cup • • 93 VAC U U M F I LTRATION accepts a 40/35 female joint 3-way valve with luer slip vent port accepts disposable syringe filters (see page 15) • Lightweight and resistant to acids for extra stability Ideal for EPA Method 1664 oil and grease analysis Not autoclavable, can be sanitized with ethanol or formaldehyde • Broad base • • S P E C I F I C AT I O N S Materials: Body and branches Valves Connections: Outlet Standard cup Temperature: Maximum " male NPT to hose barb fitting connects main manifold to 3/8" i.d. vacuum tubing Accepts #8 and #8b stopper Materials: Body and branches Valves Connections: Outlet 1/4 KMP 6 (313600) KMP 3 (313400) 60°C (140°F) LxWxH Dimensions: 3 station 6 station S P E C I F I C AT I O N S Polyvinylchloride (PVC) PTFE stopcock, PVC body in 173/4 x 43/4 x 7 341/2 x 43/4 x 7 cm 45.1 x 12 x 17.8 87.6 x 12 x 17.8 Distance between stations (center to center) in 51/2 43/4 cm 14 12 Polyvinylchloride (PVC) PTFE stopcock, PVC body KMX 3 (373330) " male NPT to hose barb fitting connects main manifold to 3/8" ID vacuum tubing 1/4 Exterior taper Temperature: Maximum 40/35 male joint Dimensions: LxWxH 60°C (140°F) Weight lb 3.3 5.5 kg 1.5 2.5 Single 3 station in 10 x 65/8 x 8 211/2 x 65/8 x 8 cm 25.4 x 16.8 x 20.3 54.6 x 16.8 x 20.3 Distance between stations (center to center) in 61/2 cm 16.5 Weight lb 4 6 kg 1.8 2.7 O R D E R I N G I N F O R M AT I O N 3 station 6 station KMP 3 KMP 6 O R D E R I N G I N F O R M AT I O N Standard cup 313400 313600 Replacement Parts 1 2 3 4 5 6 Handle Handle set screw Pipe plug PVC Hose barb Branch (Standard cup) Main manifold: 7 3 station 6 station Stopcock assembly, 2-way Exterior Taper 5 Single 3 station KMX 1 KMX 3 373130 373330 3 313401 313015 313412 Replacement Parts 7 1 373411 313410 313403 313603 313430 4 6 2 KMP 3 (313400) 1 2 3 4 5 6 7 8 9 Handle Socket cap screw Pipe plug PVC Hose barb Branch (Male taper) Branch O-ring (EPR) Stopcock assembly, 3-way 373401 373015 373412 373411 713010 373017 373430 Branch Gasket (Buna) Main manifold: 373018 1 station 3 station 373103 373303 5 6 3 7 8 1 4 9 2 KMX 3 (373330) 800-334-7132 w w w. a d v a n t e c m f s . c o m 92 VAC U U M F I LTRATION PVC Vacuum Manifold – Standard Cup PVC Extraction Manifold – Exterior Taper • Lightweight • Exterior taper • Resistant to acids • accepts a #8 and #8b stopper to adapt microanalysis units and other devices 2-way valve with PTFE stopcock in PVC body Not autoclavable • Standard cup • • 93 VAC U U M F I LTRATION accepts a 40/35 female joint 3-way valve with luer slip vent port accepts disposable syringe filters (see page 15) • Lightweight and resistant to acids for extra stability Ideal for EPA Method 1664 oil and grease analysis Not autoclavable, can be sanitized with ethanol or formaldehyde • Broad base • • S P E C I F I C AT I O N S Materials: Body and branches Valves Connections: Outlet Standard cup Temperature: Maximum " male NPT to hose barb fitting connects main manifold to 3/8" i.d. vacuum tubing Accepts #8 and #8b stopper Materials: Body and branches Valves Connections: Outlet 1/4 KMP 6 (313600) KMP 3 (313400) 60°C (140°F) LxWxH Dimensions: 3 station 6 station S P E C I F I C AT I O N S Polyvinylchloride (PVC) PTFE stopcock, PVC body in 173/4 x 43/4 x 7 341/2 x 43/4 x 7 cm 45.1 x 12 x 17.8 87.6 x 12 x 17.8 Distance between stations (center to center) in 51/2 43/4 cm 14 12 Polyvinylchloride (PVC) PTFE stopcock, PVC body KMX 3 (373330) " male NPT to hose barb fitting connects main manifold to 3/8" ID vacuum tubing 1/4 Exterior taper Temperature: Maximum 40/35 male joint Dimensions: LxWxH 60°C (140°F) Weight lb 3.3 5.5 kg 1.5 2.5 Single 3 station in 10 x 65/8 x 8 211/2 x 65/8 x 8 cm 25.4 x 16.8 x 20.3 54.6 x 16.8 x 20.3 Distance between stations (center to center) in 61/2 cm 16.5 Weight lb 4 6 kg 1.8 2.7 O R D E R I N G I N F O R M AT I O N 3 station 6 station KMP 3 KMP 6 O R D E R I N G I N F O R M AT I O N Standard cup 313400 313600 Replacement Parts 1 2 3 4 5 6 Handle Handle set screw Pipe plug PVC Hose barb Branch (Standard cup) Main manifold: 7 3 station 6 station Stopcock assembly, 2-way Exterior Taper 5 Single 3 station KMX 1 KMX 3 373130 373330 3 313401 313015 313412 Replacement Parts 7 1 373411 313410 313403 313603 313430 4 6 2 KMP 3 (313400) 1 2 3 4 5 6 7 8 9 Handle Socket cap screw Pipe plug PVC Hose barb Branch (Male taper) Branch O-ring (EPR) Stopcock assembly, 3-way 373401 373015 373412 373411 713010 373017 373430 Branch Gasket (Buna) Main manifold: 373018 1 station 3 station 373103 373303 5 6 3 7 8 1 4 9 2 KMX 3 (373330) 800-334-7132 w w w. a d v a n t e c m f s . c o m 94 VAC U U M F I LTRATION VAC U U M F I LTRATION Stainless Steel Vacuum Manifolds Replacement Parts 1 1a 2 3 4 5 • Autoclavable • 2-way or 3-way valve available, • • • use a 3-way valve when the manifold is used under closed conditions and must be vented to atmosphere without breaking the vacuum connection. 3-way valve vent is female luer slip, accepts standard disposable syringe filter (Page 15) or stainless steel syringe filter holder (KS 13, page 99) Standard cup accepts a #8 stopper to adapt microanalysis units and other devices Exterior taper accepts a 40/35 female joint Sterility Test Manifold features rear mounted flushing manifold for use in USP bacteria retentive method 6 7 Vacuum Filter Manifold Family S P E C I F I C AT I O N S 8 Materials: Body and branches Type 304 stainless steel Valves Connections: Outlet PTFE stopcock, chrome plated brass body 1/4" male NPT to hose barb fitting connects main manifold to 3/8" ID vacuum tubing Standard cup Accepts #8 and #8b stopper Exterior taper 40/35 male joint Handle standard 313101 Handle (sterility test) 313001 Handle set screw 313015 Pipe plug 313012 Hose barb 304507 Branch: Standard cup 313010 Exterior taper 613010 Main manifold: Single 361103 3 station 313003 6 station 313203 Stopcock assembly: 2-way 613005 3-way 313005 Flushing manifold (sterility test): 3 station 313004 6 station 313204 5 3 7 6 2 4 1 KM3NV (353130) 3 5 8 Standard Cup LxWxH Dimensions: Single 3 station 6 station in 8 x 43/4 x 7 18 x 43/4 x 7 281/2 x 43/4 x 7 cm 20.3 x 12 x 17.8 45.7 x 12 x 17.8 72.4 x 12 x 17.8 Distance between stations (center to center) in cm 51/2 14 43/4 12 Weight lb 5.5 9.9 14.3 Standard branch accepts a #8 or #8b stopper, 2-way valve. kg 2.5 4.5 6.5 7 6 1 1a 2 4 KM3 (313000) Exterior Taper LxWxH Dimensions: Single 3 station 6 station in 8 x 43/4 x 8 18 x 43/4 x 8 28 1/2 x4 3/4 cm 20.3 x 12 x 20.3 45.7 x 12 x 20.3 x8 72.4 x 12 x 20.3 Distance between stations (center to center) in cm 51/2 43/4 14 12 Weight lb 5.5 kg 2.5 10.4 4.7 16.9 7.7 O R D E R I N G I N F O R M AT I O N Standard cup Valve type: Single 3 station 6 station 2-way SS 2X 351120 KM3N 353100 KM6N 353300 800-334-7132 3-way SS 3X 351130 KM3NV 353130 KM6NV 353330 Exterior taper 2-way SS SPE/2 361120 KM3N XT/2 363120 KM6N XT/2 363320 3-way SS SPE/3 361130 KM3N XT/3 363130 KM6N XT/3 363330 Sterility Test (standard cup) 3-way KM3 313000 KM6 313200 Exterior taper for a 40/35 glass joint. 3-way valve. w w w. a d v a n t e c m f s . c o m 95 94 VAC U U M F I LTRATION VAC U U M F I LTRATION Stainless Steel Vacuum Manifolds Replacement Parts 1 1a 2 3 4 5 • Autoclavable • 2-way or 3-way valve available, • • • use a 3-way valve when the manifold is used under closed conditions and must be vented to atmosphere without breaking the vacuum connection. 3-way valve vent is female luer slip, accepts standard disposable syringe filter (Page 15) or stainless steel syringe filter holder (KS 13, page 99) Standard cup accepts a #8 stopper to adapt microanalysis units and other devices Exterior taper accepts a 40/35 female joint Sterility Test Manifold features rear mounted flushing manifold for use in USP bacteria retentive method 6 7 Vacuum Filter Manifold Family S P E C I F I C AT I O N S 8 Materials: Body and branches Type 304 stainless steel Valves Connections: Outlet PTFE stopcock, chrome plated brass body 1/4" male NPT to hose barb fitting connects main manifold to 3/8" ID vacuum tubing Standard cup Accepts #8 and #8b stopper Exterior taper 40/35 male joint Handle standard 313101 Handle (sterility test) 313001 Handle set screw 313015 Pipe plug 313012 Hose barb 304507 Branch: Standard cup 313010 Exterior taper 613010 Main manifold: Single 361103 3 station 313003 6 station 313203 Stopcock assembly: 2-way 613005 3-way 313005 Flushing manifold (sterility test): 3 station 313004 6 station 313204 5 3 7 6 2 4 1 KM3NV (353130) 3 5 8 Standard Cup LxWxH Dimensions: Single 3 station 6 station in 8 x 43/4 x 7 18 x 43/4 x 7 281/2 x 43/4 x 7 cm 20.3 x 12 x 17.8 45.7 x 12 x 17.8 72.4 x 12 x 17.8 Distance between stations (center to center) in cm 51/2 14 43/4 12 Weight lb 5.5 9.9 14.3 Standard branch accepts a #8 or #8b stopper, 2-way valve. kg 2.5 4.5 6.5 7 6 1 1a 2 4 KM3 (313000) Exterior Taper LxWxH Dimensions: Single 3 station 6 station in 8 x 43/4 x 8 18 x 43/4 x 8 28 1/2 x4 3/4 cm 20.3 x 12 x 20.3 45.7 x 12 x 20.3 x8 72.4 x 12 x 20.3 Distance between stations (center to center) in cm 51/2 43/4 14 12 Weight lb 5.5 kg 2.5 10.4 4.7 16.9 7.7 O R D E R I N G I N F O R M AT I O N Standard cup Valve type: Single 3 station 6 station 2-way SS 2X 351120 KM3N 353100 KM6N 353300 800-334-7132 3-way SS 3X 351130 KM3NV 353130 KM6NV 353330 Exterior taper 2-way SS SPE/2 361120 KM3N XT/2 363120 KM6N XT/2 363320 3-way SS SPE/3 361130 KM3N XT/3 363130 KM6N XT/3 363330 Sterility Test (standard cup) 3-way KM3 313000 KM6 313200 Exterior taper for a 40/35 glass joint. 3-way valve. w w w. a d v a n t e c m f s . c o m 95 96 VAC U U M F I LTRATION P RE S S U RE F I LTRATION Vacuum Pressure Pump • • • • • • Maintains continuous vacuum for filtration Also can be used for positive pressure filtration (< 60 psi) Oil free operation minimizes aerosol contamination Quiet operation Easy to maintain Portable compact design S P E C I F I C AT I O N S Materials: Wetted parts Valves Power cord Connections: Inlet and outlet ports Aluminum, stainless steel, and Nordell Normax Reed type 6‘ long, 3-wire " NPTF to hose barb fitting connects vacuum pump to 3/8" ID vacuum tubing 1/4 Power requirements Pressure: Maximum pressure 115 V, 60 Hz, 4.2 A or 220 V, 50 Hz, 1.9 A Maximum vacuum Temperature: Maximum inlet Free air capacity: Weight: 81kPa (24Hg") from atm 0.41 MPa (60 psi) VP-24 Vacuum Pressure Pump 37.8°C (100°F) 34 L/min (1.2 cfm) 9.1 Kg (20 lb) Introduction Stainless Steel Syringe Holders Stainless Steel Gas Line Holders High Pressure Stainless Steel Holder Polypropylene In-Line Holders PFA In-Line Holders Sanitary In-Line Stainless Steel Holders Vented In-Line Stainless Steel Holder Large Standard Stainless Steel Holders Large Sanitary Stainless Steel Holders Large Stainless Steel Holders with Reservoirs Multi-Media Pressure Sealing Holders Pressure Vessels Stirred Cells 98 99 100 101 102 104 105 106 107 109 111 113 115 117 O R D E R I N G I N F O R M AT I O N Model VP-24 Description Vacuum pressure pump, 115 V Vacuum pressure pump, 220 V Catalog No. 800800 800801 Replacement Parts Service kit: Replacement head gasket, filter, muffler elements, leaf valves, screws and valve retainers Catalog No. 800810 Vacuum gauge and regulator assembly 800820 Pressure gauge and regulator assembly Hose barb 3/8" 800830 800-334-7132 800840 800-334-7132