CIP 300 - Ronatec C2C

advertisement
Ronatec C2C, Inc.
Solutions In Industry
Ronatec C2C, Inc.
P.O. Box 1976
Fallbrook, CA 92028
Phone:(760) 451-9081
Orders : (800) 928-9904
Fax: (760) 946-7862
Ronatec CIP-300
Primary Application:
Ronatec CIP-300 is a highly concentrated caustic heavy duty cleaner for use in beverage and bottling
plants. The CP-300 is a low foaming and free rinsing cleaning material that removes soils from stainless
steel processing equipment. Ronatec CIP-300 is primarily used as a CIP and spray wash type capacity.
Normal Working Conditions:
Concentration:
.5% to 3% by volume
Temperature:
ambient to 190 degrees F.
Time:
contact to 5 minutes
Characteristics:
Appearance
Foam
Odor
Clear Liquid
Low
Pungent fresh smell
Operation and Solution Control:
Sample:
25 ml
Indicator:
Bromocresol Green (5 drops)
Titrate:
1.0 N HCL
Factor:
mls used x 2.0 equals % in solution
***Consult your Ronatec C2C representative for a test kit and more details***
First Aid:
If contact with eyes, flush with plenty of water for 15 minutes and seek medical attention. If contact with
skin, flush with plenty of water and remove contaminated clothing. If inhaled, get person to fresh air and
get medical attention. If ingested, do not induce vomiting and get medical attention.
Disposal:
Neutralize with acidic material and dispose of in accordance with Federal, State and Local regulations.
P.O. Box 1976, Fallbrook, Ca 92028 Phone: 760.451.9081 Fax: 760.946.7862
Ronatec CIP - 300 - Technical Data Sheet - Page 2
Material Safety Data Sheets:
Material Safety Data Sheets (M.S.D.S.) are readily available on this product. It is strongly recommended
that all personnel thoroughly read and understand the information contained in both the Technical Data
Sheet and the Material Safety Data Sheet before using this product.
Warranty:
The information presented herein, while not guaranteed, is to the best of our knowledge true and
accurate. No warranty or guarantee expressed or implied is made regarding the performance of any
products, since the manner of use is beyond our control. No suggestion for product use nor anything
contained herein, shall be construed as a recommendation for its use in infringement of any existing
patent, and we assume no responsibility or liability for operations which do infringe any such patents.
The above includes confidential and proprietary information of Ronatec C2C, Inc. and is furnished to
you for your use solely on products or processes supplied to you by us.
P.O. Box 1976, Fallbrook, Ca 92028 Phone: 760.451.9081 Fax: 760.946.7862
Download