GOVERNMENT OF MADHYA PRADESH PUBLIC WORKS

advertisement
GOVERNMENT
OF
MADHYA PRADESH
PUBLIC WORKS DEPARTMENT
SCHEDULE OF RATES
For
ELECTRICAL WORKS
in force from August 1st 2014
Issued by PROJECT DIRECTOR
Public Works Department (P.I.U.)
M.P. BHOPAL
Price : Rs. 500/(Excluding Postage and forwarding Charges etc)1
SOR ELECTRICAL 2014
Page 1 of 114
OFFICE OF THE PROJECT DIRECTOR, M.P. P.W.D. PIU, BHOPAL
No. ___________/SOR/Electric/2014
Bhopal, Dated 01.08.2014
FOREWORD
The Schedule of Rates for Electrical works published by Madhya Pradesh Public Works Department
is a comprehensive document and is very useful in the execution of internal as well as external
electrical wiring in various buildings. This Schedule of Rates is useful not only to the engineers of the
MPPWD but also to other Govt. Departments. and undertakings who follows the MPPWD Schedule of
Rates in their works.
The Schedule of Rates was last published in 2008. The prices of labour and materials have
substantially increased since then. In the meanwhile there is tremendous change in the technology in
the electrical field. Taking in to the considerations of labour rates, material cost, technological
developments and latest tools and plants the Schedule of Rates has been revised. Accordingly the
Electrical Schedule of Rates-2014 has been prepared and issued. The items of this Schedule are
based on the CPWD General Specifications for Electrical Works Part-I – Internal, 2013.
New item of LED, Luminaries, Arial Bunched Cable, Single core HT cable, 33 / 0.4 KV distribution
Transformer, Sub mains in PVC pipe, rising mains sandwich type, electric Sub-station fencing, Cable
Tray, Ornamental Pole, Power Capacitor etc have also been added in the present SOR to suit the
requirement of electrical works as per latest trend and General Specification for electrical works.
I acknowledge the efforts and hard work put in by Shri Atul Verma, Joint Project Director E&M PIU,
Shri M. K. Shukla, SE (E/M), Shri Rajesh Dubey, Executive Engineer PWD (E/M) Division Bhopal,
Shri Mukul Saxena,Executive Engineer PWD (E/M) and their devoted team of Engineers: Shri
N.H.Siddiqui , Shri Vijay Joshi, Shri Syed Shahzad Ali and Shri Kali Charan, Shri Hemant Jhariya,
who worked hard to prepare this SOR under the guidance of SE(E&M Circle) Bhopal, without which
the revision would not have been possible. I also acknowledge the valuable suggesions of Shri H. S.
Khaddar Retd. A.E. {E/M} who involved in the process of revision and final of Schedule of rates
Electrical 2014.
I am sure that this schedule of rates will be useful to all concerned.
Suggestions for improvement of this SOR are always welcome and may be e-mailed to
pdpiupwd@gmail.com
This new SOR Electrical – 2014 will be in force w.e.f. dt. 01.08.2014
Place: Bhopal
Dated :01.08.2014
(Er. Vijay Singh Verma)
Project Director
MP P.W.D. (P.I.U) Bhopal2
SOR ELECTRICAL 2014
Page 2 of 114
GENERAL NOTES
1. Definitions:
a) ’Specification’’ refers to the General Specification for Electrical Works issued
by CPWD with amendments up to date.
b) “Engineer-in-Charge” shall mean the Executive Engineer (E/M) PWD of
respective division.
c) ISI, IS, BIS shall mean the relevant Indian Standards.
2. Only Copper conductor (ICPCI approved) multi-strand cable with PVC Insulated Fire
Retardant (FR) having minimum oxygen index value 29% is to be used. Where FRLS
PVC wires are proposed to be used in the wiring system in place of FR PVC wires by
the technical sanctioning authority, they may use the schedule of rates by suitably
modifying the description of item. No separate rate has been proposed, as the
variation in cost of the item is nominal.
3. The point wiring for light/fan/bell, socket outlet 6A, 16A includes switches, sockets,
ceiling rose, lamp holder conduit, copper multi strand FR wire with copper lugs (
required to be compulsorily used ), fixing and drawing of all items and green colour
PVC insulated Multi strand FR copper wire as earth wire. However, Switch Board with
sheet - modular or non-modular type is not included in the rates of point wiring and
shall be paid separately and switch boards should be selected so as to accommodate
at least similar one switch & socket in future.
4. Circuit wiring is to be done in 2.5 sq mm cable. The rates of the earth wire of green
colour of 2.5 sq mm copper Multi strand FR to be run inside the same conduit shall be
payable separately as per actual measurements. Similarly, green colour earth wire for
sub-main shall run inside the same conduit and shall be paid separately. Separate
conduit shall be used for point, circuit and sub-main wiring.
5. Modular accessories are to be used in residential buildings of "E type and above and
in case of non-residential buildings costing more than 50 Lac. All non-modular and
modular accessories are to be of polycarbonate material only.
6. The rates of wiring have been taken considering the FR wire only. If anywhere, the
FR-LSH wire is used, 3% rates may be paid additionally.3
7. Star rating ceiling fans confirming to IS: 374/1979 with amended up to date, ISI
SOR ELECTRICAL 2014
Page 3 of 114
marked and Star rated distribution Transformer, Arial Bunched cable of 1.1 KV, 11
KV, 33 KV, LED Luminaries, domestic & street lights, step light are added.
8. Only XLPE insulated LT/HT cables are to be used and rates have been provided
accordingly. Modular accessories, in addition to normal (non-modular), are also
introduced and rates have been given accordingly.
9. Chapter on overhead electrification is also enhanced covering as per Norms of
MPSEB.
10. The rates given in this SOR are based on the following classification:
CLASSIFICATION OF POINTS:
Point
Light / Fan / Bell / 2 Way Points Power Wiring 16A
/ Socket 6A etc.
Short
Up to 3m.
Up to 3m.
Medium
Above 3m up to 6m
Above 3m up to 6m
Long
Above 6m up to 10m
Above 6m up to 10m
Extra Long-I
Above 10m up to 15m
Extra Long-II
Above 15m up to 20m
Extra Long-III
Above 20m up to 25m
NOTE:
1) Special Points – Actual material used above 10 m (Light Point etc)/ 25m
(Power Wiring) shall be paid as per actual measurements on linear basis.
2) Any special wiring not covered above shall be measured on the linear basis
and shall be paid as per SOR items.
11. In this S.O.R. on chapter No. 40 the rates of dismantling of wiring in F/G/H/I type qtrs
and rewiring of same have been taken as single item. The rate of item 40.1 does not
include service line, earthling system, Fans and light fixtures.
12. In this S.O.R. on chapter No. 40 the rates of new wiring in standard F/G/H/I type qtrs
have been taken as single item. The rate of item 40.2 include Fans and light fixtures. 4
13. The material is to be used as per “List of approved electrical material” annexed
SOR ELECTRICAL 2014
Page 4 of 114
herewith. However, the SE (E/M) / Joint Project Director E&M PIU PWD shall be
authorized to add the material of new make/model keeping in the list from time to time
in view the quality and the required specifications. In case of non-availability of
material as specified in the list of approved materials, in any particular area or at any
time, the Engineer-in-Charge may permit the use of material of the different equivalent
make / model in the said agreement after taking permission from S.E. (E&M) / Joint
Project Director E&M PIU PWD.
14. The rates given are for finished complete work. All material, labour, wastage,
royalties, taxes, lease rent, scaffolding, temporary work , T&P hire charges, breakage,
making good any damage to wall, surface, fitting etc. to original finish, transportation,
replacement of any defective material, theft, pilferage, insurance, variation in market
rates etc. are included in the rates, unless specified otherwise. Removal of rubbish,
dismantled material, cleaning of work/site is also included in the rates .Rectification of
work due to defective/ inappropriate materials and or workmanship is also included in
the rates of present SOR .
15. In case of contradiction/conflict in the provisions of this SOR and CPWD
Specifications, the former will prevail. In situations, where the provisions are not
provided or silent in this SOR, the provisions of CPWD specification shall apply.
However decision of Engineer-in-charge shall be final and binding.
16. Use of LED Lights, decorative fans shall be permitted in non residential buildings only.
(Er. Vijay Singh Verma)
Project Director
MP P.W.D. (P.I.U) Bhopal5
SOR ELECTRICAL 2014
Page 5 of 114
CONTENTS
CHAPTER
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
DESCRIPTION
PAGE No.
WIRING IN SURFACE RIGID STEEL CONDUIT SYSTEM WITH
COPPER CONDUCTOR
WIRING IN CONCEALED RIGID STEEL CONDUIT SYSTEM
WITH COPPER CONDUCTOR
WIRING IN SURFACE RIGID P.V.C. CONDUIT SYSTEM WITH
COPPER CONDUCTOR
WIRING
IN
CONCEALED
RIGID
P.V.C.
CONDUIT
(HMS)SYSTEM
WIRING IN SURFACE RIGID P.V.C. CASING-N-CAPING
SYSTEM WITH COPPER CONDUCTOR
POWER WIRING IN SURFACE RIGID STEEL CONDUIT
SYSTEM WITH COPPER CONDUCTOR
POWER WIRING IN CONCEALD RIGID STEEL CONDUIT
SYSTEM WITH COPPER CONDUCTOR
POWER WIRING IN SURFACE RIGID PVC CONDUIT SYSTEM
WITH COPPER CONDUCTOR.
POWER WIRING IN CONCEALED RIGID PVC CONDUIT
SYSTEM WITH COPPER CONDUCTOR
POWER WIRING IN SURFACE RIGID PVC CASING-N-CAPING
SYSTEM WITH COPPER CONDUCTOR
WIRING IN EXISTING CONCEALED RIGID CONDUIT SYSTEM
WITH COPPER CONDUCTOR
WIRING IN EXISTING SURFACE RIGID CONDUIT SYSTEM
WITH COPPER CONDUCTOR
SUPPLYING AND FIXING RIGID STEEL CONDUIT FOR
CONCEALED CONDUIT SYSTEM
SUPPLYING AND FIXING RIGID STEEL CONDUIT FOR
SURFACE CONDUIT SYSTEM
SUPPLYING AND FIXING PVC CONDUIT FOR SURFACE
CONDUIT SYSTEM
SUPPLYING AND FIXING PVC CONDUIT(HMS) FOR
CONCEALED CONDUIT SYSTEM
SUPPLYING AND FIXING PVC CASING - N - CAPPING ON
SURFACE SYSTEM
METALLIC SWITCH BOXES & MODULAR BOXES
8
WIRING IN EXISTING CONDUIT/ PVC CASING-N-CAPPING
WITH COPPER CONDUCTOR
MAINS AND SUB MAINS IN SURFACE STEEL CONDUIT WITH
COPPER CONDUCTOR
SUB-MAIN IN CONCEALED STEEL CONDUIT WITH COPPER
CONDUCTOR
9
10
11
12
13
13
14
14
15
16
17
18
18
19
19
19
20
21-22
23
246
SOR ELECTRICAL 2014
Page 6 of 114
22
SUB MAINS IN SURFACE PVC CONDUIT IN COPPER
CONDUCTOR
25
23
SUB-MAIN IN CONCEALED PVC CONDUIT IN COPPER
CONDUCTOR
REWIRING IN EXISTING RIGID STEEL / PVC NON- METALLIC
CONDUIT WITH COPPER CONDUCTOR
CONTROL SWITCH GEARS
BUSBAR CHAMBERS AND BUS TRUNKING
MCCBs, ISOLATORS ,MCBs ,RCBOs ,MCB DBs
FIXING OF SFU ,DBs ,BUSBAR ,MCCBs ,MCBs, ISOLATORs &
RCBOs
WIRING ACCESSORIES,PANELS,LAMPS,
FAN
LUMINAIRES
MISCELLANEOUS
LABOUR RATES FOR WIRING
PAINTING
DISMANTLING OF CIVIL & ELECTRICAL WORK
CIVIL WORK
EARTHING, LOOP EARTHING, LIGHTNING CONDUCTOR
TELEPHONE, LAN, TV CABLE
SINGLE / THREE PHASE SUBMERSIBLE / OPENWELL /
CENTRIFUGAL MOTOR PUMP SET.
WIRING OF OLD STANDARD F/G/H/I QTRS & NEW WIRING
OF NEW STANDARD F/G/H/I QTRS
UNDER GROUND CABLES
EXTERNAL ELECTRIFICATION AND OVERHEAD LINES
LIST OF APPROVED MATERIAL
ANNEXURE -1, GUIDE LINE FOR REWIRING
26
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
27-28
29-33
34-36
37-42
43-44
45-49
50-51
52-60
61-63
64-65
66
67-68
68
69-73
74-75
76-78
79
80-93
94-111
112-113
1147
SOR ELECTRICAL 2014
Page 7 of 114
CHAPTER – 1
WIRING IN SURFACE RIGID STEEL CONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.No.
Description of Item
1
Point wiring (excluding metallic switch box & sheet but
including switches, sockets, lamp holders/ceiling roses
etc) with 1.5 Sq. mm. PVC insulated cable FR with
copper multi strand conductor ISI marked in surface rigid
steel conduit ISI Marked of suitable size and 1.5 Sq. mm.
PVC insulated copper earth continuity conductor of green
colour inside conduit including painting, etc. as required
as per specification for :Light Point/Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Point wiring (excluding metallic switch box & sheet but
including switches, sockets ) for 3/5 pin 6 Amp. Socket
outlet point with 1.5 Sq. mm. PVC insulated cable FR
with copper multi strand conductor ISI marked in surface
rigid steel conduit ISI marked of suitable size and 1.5 Sq.
mm. PVC insulated copper earth continuity conductor of
green colour inside conduit with required materials as per
specification on same board
Wiring for circuit wiring with PVC insulated cable FR with
copper multi strand conductor ISI marked in surface rigid
steel conduit of ISI marked suitable size including painting
etc. as required as per specification
a) 2x2.5 Sq.mm.
b) 4x2.5 Sq.mm.
c) 6x2.5 Sq.mm.
d) 8x2.5 Sq.mm.
1.1
1.2
1.3
1.4
1.5
1.6
Unit
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessori s
es
Each
Each
Each
445
959
1546
533
1047
1634
Each
Each
Each
453
996
1626
647
1189
1820
Each
Each
Each
417
888
1424
526
997
1533
Each
Each
Each
Each
480
1032
1680
606
1158
1807
91
285
182
253
304
356
182
253
304
3568
meter
meter
meter
meter
SOR ELECTRICAL 2014/CHAPTER-1
Page 8 of 114
CHAPTER – 2
WIRING IN CONCEALED RIGID STEEL CONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.No
Description of Item
2
Point wiring (excluding metallic switch box & sheet but
including switches, sockets, lamp holders/ceiling roses
etc) with 1.5 Sq. mm. PVC insulated cable FR with
copper multi strand conductor ISI marked in Concealed
rigid steel conduit ISI Marked of suitable size and 1.5 Sq.
mm. PVC insulated copper earth continuity conductor of
green colour inside conduit including painting, etc. as
required as per specification for :-
2.1
Light Point/Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Point wiring (excluding metallic switch box & sheet but
including switches, sockets ) for 3 pin 6 Amp. Socket
outlet point with 1.5 Sq. mm. PVC insulated cable FR
with copper multi strand conductor ISI marked
in
Concealed rigid steel conduit ISI marked of suitable size
and 1.5 Sq. mm. PVC insulated copper earth continuity
conductor of green colour inside conduit with required
materials as per specification on same board
Wiring for circuit wiring with PVC insulated cable FR with
copper multi strand conductor ISI marked in Concealed
rigid steel conduit of ISI marked suitable size including
painting etc. as required as per specification
a) 2x2.5 Sq.mm.
b) 4x2.5 Sq.mm.
c) 6x2.5 Sq.mm.
d) 8x2.5 Sq.mm.
2.2
2.3
2.4
2.5
2.6
Unit
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessori s
es
Each
Each
Each
481
1028
1685
569
1116
1772
Each
Each
Each
488
1049
1764
683
1258
1959
Each
Each
Each
439
936
1536
556
1054
1654
Each
Each
Each
498
1060
1732
616
1183
1860
Each
91
285
metre
metre
metre
metre
200
270
321
373
200
270
321
3739
SOR ELECTRICAL 2014/CHAPTER-2
Page 9 of 114
CHAPTER – 3
WIRING IN SURFACE RIGID P.V.C. CONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.No
Description of Item
3
Point wiring (excluding metallic switch box & sheet but
including switches, sockets, lamp holders/ceiling roses
etc) with 1.5 Sq. mm. PVC insulated cable FR with
copper multi strand conductor ISI marked in Surface rigid
P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5
Sq. mm. PVC insulated copper earth continuity conductor
of green colour inside conduit etc. as required as per
specification for :-
3.1
Light Point/Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Point wiring (excluding metallic switch box & sheet but
including switches, sockets) for 3 pin 6 Amp. Socket outlet
point with 1.5 Sq. mm. PVC insulated cable FR with
copper multi strand conductor ISI marked in Surface rigid
P.V.C. conduit (MMS) ISI marked of suitable size and 1.5
Sq. mm. PVC insulated copper earth continuity conductor
of green colour inside conduit with required materials as
per specification on same board .
3.2
3.3
3.4
3.5
3.6
Wiring for circuit wiring with PVC insulated cable FR with
copper multi strand conductor ISI marked in Surface rigid
P.V.C. conduit (MMS) of ISI marked suitable size etc. as
required as per specification
a) 2x2.5 Sq.mm.
b) 4x2.5 Sq.mm.
c) 6x2.5 Sq.mm.
d) 8x2.5 Sq.mm.
Unit
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessori s
es
Each
Each
Each
240
432
736
335
548
842
Each
Each
Each
253
498
824
454
723
1044
Each
Each
Each
213
399
615
283
474
696
Each
Each
Each
258
503
816
381
649
956
Each
91
285
Metre
Metre
Metre
Metre
93
153
204
255
93
153
204
25510
SOR ELECTRICAL 2014/CHAPTER-3
Page 10 of 114
CHAPTER – 4
WIRING IN CONCEALED RIGID PVC CONDUIT(HMS) SYSTEM WITH COPPER
CONDUCTOR
S.No.
Description of Item
4
Point wiring (excluding metallic switch box & sheet but
including switches,sockes,lamp,holders,ceiling roses etc)
with 1.5 Sq. mm. PVC insulated cable FR with copper
multi strand conductor ISI marked in concealed rigid
P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5
Sq. mm. PVC insulated copper earth continuity conductor
of green colour inside conduit etc. as required as per
specification for :-
4.1
Light Point/Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Point wiring (excluding metallic switch box & sheet but
including switches, sockets) for 3 pin 6 Amp. Socket outlet
point with 1.5 Sq. mm. PVC insulated cable FR with
copper multi strand conductor ISI marked in concealed
rigid P.V.C. conduit (HMS) ISI marked of suitable size
and 1.5 Sq. mm. PVC insulated copper earth continuity
conductor of green colour inside conduit with required
materials as per specification on same board .
Wiring for circuit wiring with PVC insulated cable FR with
copper multi strand conductor ISI marked in concealed
rigid P.V.C. conduit (HMS) of ISI marked suitable size
etc. as required as per specification
4.2
4.3
4.4
4.5
4.6
a)
b)
c)
d)
2x2.5 Sq.mm.
4x2.5 Sq.mm.
6x2.5 Sq.mm.
8x2.5 Sq.mm.
Unit
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessori s
es
Each
Each
Each
294
564
942
394
671
1083
Each
Each
Each
302
601
1022
503
780
1192
Each
Each
Each
268
509
821
388
637
983
Each
Each
Each
335
638
1048
486
812
1285
Each
91
285
Metre
Metre
Metre
Metre
117
176
225
277
117
176
225
27711
SOR ELECTRICAL 2014/CHAPTER-4
Page 11 of 114
CHAPTER – 5
WIRING IN SURFACE RIGID PVC CASING AND CAPPING SYSTEM WITH COPPER
CONDUCTOR
S.No.
Description of Item
5
Point wiring (excluding metallic switch box & sheet but
including switches, sockets, lamp holders/ceiling roses
etc) with 1.5 Sq. mm. PVC insulated cable FR with
copper multi strand conductor ISI marked in Surface rigid
P.V.C. CASING AND CAPPING ISI Marked of suitable
size and 1.5 Sq. mm. PVC insulated copper earth
continuity conductor of green colour inside casing &
capping etc. as required as per specification for :-
5.1
Light Point/Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Point wiring (excluding metallic switch box & sheet but
including switches, sockets ) for 3 pin 6 Amp. Socket
outlet point with 1.5 Sq. mm. PVC insulated cable FR
with copper multi strand conductor ISI marked in Surface
rigid P.V.C. CASING AND CAPPING ISI marked of
suitable size and 1.5 Sq. mm. PVC insulated copper earth
continuity conductor of green colour inside casing &
capping with required materials as per specification on
same board
5.2
5.3
5.4
5.5
5.6
Unit
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessori s
es
Each
Each
Each
228
447
699
339
584
866
Each
Each
Each
236
483
779
453
727
1053
Each
Each
Each
235
453
706
332
534
767
Each
Each
Each
269
521
808
399
677
994
Each
91
285
Metre
Metre
Metre
Metre
102
153
204
254
102
153
204
25412
Wiring for circuit wiring with PVC insulated cable FR with
copper multi strand conductor ISI marked in Surface rigid
P.V.C. CASING AND CAPPING of ISI marked suitable
size etc. as required as per specification
a)
b)
c)
d)
2x2.5 Sq.mm.
4x2.5 Sq.mm.
6x2.5 Sq.mm.
8x2.5 Sq.mm.
SOR ELECTRICAL 2014/CHAPTER-5
Page 12 of 114
CHAPTER – 6
POWER WIRING IN SURFACE RIGID STEEL CONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.No
6.1
Description of Item
Point wiring (excluding metallic switch box & sheet ) for 3
Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC
insulated cable FR with copper multi strand conductor ISI
marked in Surface rigid Steel Conduit ISI Marked of
suitable size including painting etc. with 16 Amp. Switch &
Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq.
mm. PVC insulated copper earth continuity conductor of
green colour inside conduit as per specification for :On Separate Board
A.
B.
C.
D.
E.
6.2
Unit
Short Point
Medium Point
Long Point
Extra Long –I
Extra Long –II
F. Extra Long –III
Same board switch socket 6/16 Amp
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessorie s
s
Each
Each
Each
Each
Each
659
1360
2173
3170
4287
914
1615
2428
3425
4542
Each
Each
5660
213
5915
468
CHAPTER – 7
POWER WIRING IN CONCEALED RIGID STEELCONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.No
Description of Item
7.1
Point wiring (excluding metallic switch box & sheet ) for 3
Pin 16 Amp. Socket Outlet Point with 4 Sq. mm. PVC
insulated cable FR with copper multi strand conductor ISI
marked in Concealed rigid Steel Conduit ISI Marked of
suitable size including painting etc. with 16 Amp. Switch &
Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq.
mm. PVC insulated copper earth continuity conductor of
green colour inside conduit as per specification for :-
Unit
Rate (Rs)
Using
Using
Flush Type Modular
Normal
Accessorie
Accessori s
es
On Separate Board
A.
B.
C.
D.
E.
7.2
Short Point
Medium Point
Long Point
Extra Long –I
Extra Long –II
F. Extra Long –III
Same board switch socket 6/16 Amp
Each
Each
Each
Each
691
1384
2194
3216
950
1645
2459
3486
Each
Each
Each
4349
5666
213
4623
5944
46813
SOR ELECTRICAL 2014/CHAPTER-6-7
Page 13 of 114
CHAPTER – 8
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (MMS) SYSTEM WITH
COPPER CONDUCTOR
S.No
Description of Item
8.1
Point wiring (excluding metallic switch box & sheet ) for 3
Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC
insulated cable FR with copper multi strand conductor ISI
marked in Surface rigid P.V.C, Conduit (MMS) ISI Marked
of suitable size etc. with 16 Amp. F.T. Switch & Socket /
S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm.
PVC insulated copper earth continuity conductor of green
colour inside conduit as per specification for :On Separate Board
A. Short Point
B. Medium Point
C. Long Point
D. Extra Long –I
E. Extra Long –II
E. Extra Long –III
8.2
Same board switch socket 6/16 Amp
Unit
Each
Each
Each
Each
Each
Each
Each
Rate (Rs)
Using Flush Using
Type
Modular
Normal
Accessories
Accessorie
s
477
919
1442
2111
2846
3586
213
732
1174
1697
2366
3101
3841
468
CHAPTER – 9
POWER WIRING IN CONCEALED RIGID PVC CONDUIT (HMS) SYSTEM WITH
COPPER CONDUCTOR
S.N.
Description of Item
Unit
Rate (Rs)
9.1
Using
Flush Type
Normal
Accessori
es
Point wiring (excluding metallic switch box & sheet ) for 3
Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC
insulated cable FR with copper multi strand conductor ISI
marked in Concealed rigid P.V.C Conduit (HMS) ISI
Marked of suitable size etc. with 16 Amp. F.T. Switch &
Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq.
mm. PVC insulated copper earth continuity conductor of
green colour inside conduit as per specification for
Using
Modular
Accessorie
s
On Separate Board
A.
B.
C.
D.
E.
F.
9.2
Short Point
Medium Point
Long Point
Extra Long –I
Extra Long –II
Extra Long –III
Same board switch socket 6/16 Amp
Each
Each
Each
Each
Each
574
1113
1730
2474
3280
816
1335
1930
2643
3417
Each
4089
4193
Each
213
46814
SOR ELECTRICAL 2014/CHAPTER-8-9
Page 14 of 114
CHAPTER – 10
POWER WIRING IN SURFACE RIGID PVC CASING AND CAPPING SYSTEM WITH
COPPER CONDUCTOR
S.N.
10.1
10.2
Description of Item
Point wiring (excluding metallic switch box & sheet)
for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq.
mm. PVC insulated cable FR with copper multi
strand conductor ISI marked in Surface rigid
P.V.C.CASING AND CAPPING ISI Marked of
suitable size etc. with 16 Amp. F.T. Switch & Socket
/ S.S Combined 6/16 Amp. of ISI Marked and 4 Sq.
mm. PVC insulated copper earth continuity
conductor of green colour inside capping as per
specification for :On Separate Board
A. Short Point
B. Medium Point
C. Long Point
D. Extra Long –I
E. Extra Long –II
F. Extra Long –III
Same board switch socket 6/16 Amp
Unit
Rate (Rs)
Using Flush Using
Type
Modular
Normal
Accessories
Accessories
Each
Each
Each
Each
Each
Each
Each
493
963
1518
2231
3014
3797
213
747
1215
1768
2479
3259
4039
46815
SOR ELECTRICAL 2014/CHAPTER-10
Page 15 of 114
CHAPTER – 11
WIRING IN EXISTING CONCEALED RIGID CONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.N.
11
11.1
11.2
11.3
11.4
Description of Item
Point wiring (excluding metallic switch box & sheet
but including switches, sockets, lamp holders/ceiling
roses etc) with 1.5 Sq. mm. PVC insulated cable FR
with copper multi strand conductor ISI marked in
existing Concealed rigid conduit ISI Marked of
suitable size with PVC insulated copper earth
continuity conductor of green colour as per
specification including earthling of regulator etc as
required for :Light Point / Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Unit
Rate (Rs)
Using Flush Using
Type
Modular
Normal
Accessories
Accessories
Each
Each
Each
184
350
542
269
435
627
Each
Each
Each
188
354
545
374
540
731
Each
Each
Each
157
279
420
242
364
505
Each
Each
Each
224
395
589
347
518
71216
SOR ELECTRICAL 2014/CHAPTER-11
Page 16 of 114
CHAPTER – 12
WIRING IN EXISTING SURFACE RIGID CONDUIT SYSTEM WITH COPPER
CONDUCTOR
S.No
Description of Item
Unit
Rate (Rs)
12
12.1
12.2
12.3
12.4
Point wiring (excluding metallic switch box & sheet
but including switches, sockets,lamp holders/ceiling
roses etc) with 1.5 Sq. mm. PVC insulated cable with
Copper Stranded Conductor ISI marked in existing
surface rigid conduit ISI Marked of suitable size with
PVC insulated copper earth continuity conductor of
green colour as per specification including earthing of
regulator etc as required for :Light Point / Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
a) Short point
b) Medium point
c) Long point
Call Bell / Buzzer Points
a) Short point
b) Medium point
c) Long point
Twin Control light points
a) Short point
b) Medium point
c) Long point
Using Flush Using
Type
Modular
Normal
Accessories
Accessories
Each
Each
Each
178
344
535
263
429
620
Each
Each
Each
181
347
539
367
533
725
Each
Each
Each
150
272
413
235
357
498
Each
Each
Each
217
388
582
340
511
70517
SOR ELECTRICAL 2014/CHAPTER-12
Page 17 of 114
CHAPTER – 13
SUPPLYING AND FIXING RIGID STEEL CONDUIT FOR CONCEALED CONDUIT
SYSTEM
S.No
13
13.1
13.2
13.3
13.4
13.5
Description of Item
Supplying and fixing rigid steel conduit ISI marked along with
the accessories in concealed system including cutting the wall
and plastering & repainting the wall with matching colour to
bring in its original condition as required
H.G. Conduit 20 mm, wall thickness-1.6mm
H.G. Conduit 25 mm, wall thickness-1.6mm
H.G. Conduit 32 mm, wall thickness-1.6mm
H.G. Conduit 40 mm, wall thickness-2.0mm
H.G. Conduit 50 mm, wall thickness-2.0mm
Unit
Metre
Metre
Metre
Metre
Metre
Rate(Rs)
116
137
198
307
424
CHAPTER – 14
SUPPLYING AND FIXING RIGID STEEL CONDUIT FOR SURFACE CONDUIT
SYSTEM
Description of Item
S.No
Unit
Rate(Rs)
14
14.1
14.2
14.3
14.4
14.5
Supplying and fixing rigid steel conduit ISI marked along with
the accessories on surface including painting etc. as required
H.G. Conduit 20 mm, wall thickness-1.6mm
H.G. Conduit 25 mm, wall thickness-1.6mm
H.G. Conduit 32 mm, wall thickness-1.6mm
H.G. Conduit 40 mm, wall thickness-2.0mm
H.G. Conduit 50 mm, wall thickness-2.0mm
Metre
Metre
Metre
Metre
Metre
99
124
180
283
39318
SOR ELECTRICAL 2014/CHAPTER-13-14
Page 18 of 114
CHAPTER – 15
SUPPLYING AND FIXING PVC. CONDUIT FOR SURFACE CONDUIT SYSTEM
S.No
15
15.1
15.2
15.3
15.4
15.5
Description of Item
Unit
Rate(Rs)
Supplying and fixing PVC conduit ISI marked along with the
accessories on surface etc. as required
PVC . Conduit 20 mm (MMS)
Metre
PVC . Conduit 25 mm (MMS)
Metre
PVC . Conduit 32 mm (MMS)
Metre
PVC . Conduit 40 mm (MMS)
Metre
PVC . Conduit 50 mm (MMS)
Metre
39
51
72
103
151
CHAPTER – 16
SUPPLYING AND FIXING PVC CONDUIT(HMS) FOR CONCEALED CONDUIT
SYSTEM
S.No
16
16.1
16.2
16.3
16.4
16.5
Description of Item
Unit
Supplying and fixing PVC conduit ISI marked along with the
accessories in concealed system etc. as required
PVC . Conduit 20 mm (HMS)
Metre
PVC . Conduit 25 mm (HMS)
Metre
PVC . Conduit 32 mm (HMS)
Metre
PVC . Conduit 40 mm (HMS)
Metre
PVC . Conduit 50 mm (HMS)
Metre
Rate(Rs)
61
72
108
137
196
CHAPTER - 17
SUPPLYING AND FIXING PVC CASING - N - CAPPING ON SURFACE SYSTEM
S.No
17
17.1
17.2
17.3
17.4
Description of Item
Supplying and fixing PVC Casing-N-Capping (Double Fold)
ISI Marked along with accessories on surface etc. as
required
PVC Casing-N-Capping (Double Fold) 20 mm x 12mm
PVC Casing-N-Capping (Double Fold) 25 mm x 12mm
PVC Casing-N-Capping (Double Fold) 32 mm x 12mm
PVC Casing-N-Capping (Double Fold) 38 mm x 20mm
Unit
Rate( in
Rs)
Per Mtr
Per Mtr
Per Mtr
Per Mtr
40
48
49
6619
SOR ELECTRICAL 2014/CHAPTER-15-17
Page 19 of 114
CHAPTER – 18
METALLIC SWITCH BOXES & MODULAR BOXES
S.No
18.1
18.1.1
Description of Item
Unit
Rate(Rs)
Supplying and fixing factory fabricated hot dip galvanized switch
box for normal flush type accessories of minimum 1.2 mm (18
SWG gauge) thickness with earth terminal stud with nut and
washer, with 3 mm thick synthetic phenollic resin bonded laminated
sheet conforming to grade P-I of IS:2036-1974 on surface /
concealed including painting etc. as required as per specification:
FOR SURFACE/CONCEALED
MS Box 100 mm X 100 mm X60mm deep
Each
98
18.1.2
MS Box 200 mm X 150 mm X 60 mm Deep
Each
181
18.1.3
MS Box 180 mm X 100 mm X 60 mm Deep
Each
133
18.1.4
MS Box 125 mm X 300 mm X 60 mm Deep
Each
237
18.1.5
MS Box 200 mm X 250 mm X 60 mm Deep
Each
271
18.1.6
MS Box 250 mm X 300 mm X 60 mm Deep 1.6mm(16swg)
Each
427
18.1.7
MS Box 300mm X 380 mm X 60 mm Deep 1.6mm(16swg)
Each
594
18.2.1
Supplying and fixing of approved make modular type metal box
with modular frame/ base plate and cover plate including fixing in
concealed / surface excluding switch,socket etc. as required for:1 Or 2 Module
Each
156
18.2.2
3 Module
Each
208
18.2.3
4 Module
Each
236
18.2.4
6 Module
Each
326
18.2.5
8 / 9 Module
Each
400
18.2.6
12 Module
Each
487
18.2.7
16 Module
Each
532
18.2.8
18 Module
Each
560
18.3.1
Supplying and fixing of approved make modular type P.V.C. box
with modular base and cover plate including fixing on surface
excluding switch,socket etc. as required for:1 OR 2 Module
Each
151
18.3.2
3 Module
Each
184
18.3.3
4 Module
Each
218
18.3.4
6 Module
Each
280
18.3.5
8 / 9 Module
Each
356
18.3.6
12 Module
Each
453
18.3.7
16 Module
Each
49220
18.2
18.3
SOR ELECTRICAL 2014/CHAPTER-18
Page 20 of 114
CHAPTER -19
WIRING IN EXISTING CONDUIT / PVC CASING CAPPING WITH COPPER
CONDUCTOR
S.No
19
19.1
Description of Item
Unit
Rate(Rs)
Supplying and drawing single core PVC insulated cable FR with
copper multi strand conductor ISI marked in existing rigid PVC
Casing-N-Capping / conduit in surface or concealed as per
specification.
1 X 1.5 sq mm
19.1.1
(a) 1 X 1.5 sq mm
Per Mtr
21
19.1.2
(b) 2 X 1.5 sq mm
Per Mtr
36
19.1.3
(c) 3 X 1.5 sq mm
Per Mtr
51
19.1.4
(d) 4 X 1.5 sq mm
Per Mtr
67
19.1.5
(e) 5 X 1.5 sq mm
Per Mtr
82
19.1.6
(f) 6 X 1.5 sq mm
Per Mtr
97
19.1.7
(g) 7 X 1.5 sq mm
Per Mtr
113
19.1.8
(h) 8 X 1.5 sq mm
Per Mtr
128
19.1.9
(i) 9 X 1.5 sq mm
Per Mtr
143
19.1.10
(j) 10 X 1.5 sq mm
Per Mtr
159
19.2
1 X 2.5 sq mm
19.2.1
(a) 1 X 2.5 sq mm
Per Mtr
30
19.2.2
(b) 2 X 2.5 sq mm
Per Mtr
54
19.2.3
(c) 3 X 2.5 sq mm
Per Mtr
78
19.2.4
(d) 4 X 2.5 sq mm
Per Mtr
103
19.2.5
(e) 5 X 2.5 sq mm
Per Mtr
127
19.2.6
(f) 6 X 2.5 sq mm
Per Mtr
151
19.2.7
(g) 7 X 2.5 sq mm
Per Mtr
176
19.2.8
(h) 8 X 2.5 sq mm
Per Mtr
200
19.2.9
(i) 9 X 2.5 sq mm
Per Mtr
224
19.2.10
(j) 10 X 2.5 sq mm
Per Mtr
225
19.3
1 X 4.00 sq mm
19.3.1
(a) 1 X 4.00 sq mm
Per Mtr
41
19.3.2
(b) 2 X 4.00 sq mm
Per Mtr
76
19.3.3
(c) 3 X 4.00 sq mm
Per Mtr
111
19.3.4
(d) 4 X 4.00 sq mm
Per Mtr
147
19.3.5
(e) 5 X 4.00 sq mm
Per Mtr
18221
SOR ELECTRICAL 2014/CHAPTER-19
Page 21 of 114
19.3.6
(f) 6 X 4.00 sq mm
Per Mtr
196
19.3.7
(g) 7 X 4.00 sq mm
Per Mtr
252
19.3.8
(h) 8 X 4.00 sq mm
Per Mtr
288
19.3.9
(i) 9 X 4.00 sq mm
Per Mtr
323
19.3.10
(j) 10 X 4.00 sq mm
Per Mtr
358
19.4
1 X 6.00 sq mm
19.4.1
(a) 1 X 6.00 sq mm
Per Mtr
58
19.4.2
(b) 2 X 6.00 sq mm
Per Mtr
111
19.4.3
(c) 3 X 6.00 sq mm
Per Mtr
163
19.4.4
(d) 4 X 6.00 sq mm
Per Mtr
216
19.4.5
(e) 5 X 6.00 sq mm
Per Mtr
269
19.4.6
(f) 6 X 6.00 sq mm
Per Mtr
322
19.4.7
(g) 7 X 6.00 sq mm
Per Mtr
374
19.4.8
(h) 8 X 6.00 sq mm
Per Mtr
427
19.4.9
(i) 9 X 6.00 sq mm
Per Mtr
480
19.4.10
(j) 10 X 6.00 sq mm
Per Mtr
532
19.5
10.00 Sq mm cable
19.5.1
1 X 10.00 sq mm
Per Mtr
88
19.5.2
2 X 10.00 sq mm
Per Mtr
170
19.5.3
3 X 10.00 sq mm
Per Mtr
252
19.5.4
4 X 10.00 sq mm
Per Mtr
334
19.5.5
5 X 10.00 sq mm
Per Mtr
416
19.5.6
6 X 10.00 sq mm
Per Mtr
498
19.6
16.00 Sq mm cable
19.6.1
1 X 16.00 sq mm
Per Mtr
136
19.6.2
2 X 16.00 sq mm
Per Mtr
268
19.6.3
3 X 16.00 sq mm
Per Mtr
399
19.6.4
19.7
4 X 16.00 sq mm
Per Mtr
530
25.00 Sq mm cable
19.7.1
1 X 25.00 sq mm
Per Mtr
207
19.7.2
2 X 25.00 sq mm
Per Mtr
408
19.7.3
3 X 25.00 sq mm
Per Mtr
610
19.7.4
19.8
4 X 25.00 sq mm
Per Mtr
811
35.00 Sq mm cable
19.8.1
1 X 35.00 sq mm
Per Mtr
288
19.8.2
2 X 35.00 sq mm
Per Mtr
571
19.8.3
3 X 35.00 sq mm
Per Mtr
854
19.8.4
4 X 35.00 sq mm
Per Mtr
113622
SOR ELECTRICAL 2014/CHAPTER-19
Page 22 of 114
CHAPTER - 20
SUB MAINS IN SURFACE STEEL CONDUIT IN COPPER CONDUCTOR
S.No
20
20.1
20.1.1
20.1.2
20.1.3
20.1.4
20.1.5
20.1.6
20.1.7
20.2
20.2.1
20.2.2
20.2.3
20.2.4
20.2.5
20.2.6
20.2.7
20.3
20.3.1
20.3.2
20.3.3
20.3.4
20.3.5
20.3.6
20.3.7
20.4
20.4.1
20.4.2
20.4.3
20.4.4
20.4.5
20.4.6
20.4.7
Description of Item
Wiring for sub-mains with PVC insulated cable FR with
copper multi strand conductor ISI marked in surface rigid
steel ISI marked conduit of suitable size(conduit included)
including accessories long neck threaded type, connection
painting etc ,as required as per specification
2 WIRE SUB MAIN
a) 2.5 sq mm cable in 20 mm conduit
b) 4.0 sq mm cable in 20 mm conduit
c) 6.0 sq mm cable in 20 mm conduit
d) 10.0 sq mm cable in 25 mm conduit
e) 16.0 sq mm cable in 25 mm conduit
f) 25.0 sq mm cable in 32 mm conduit
g) 35.0 sq mm cable in 32 mm conduit
3 WIRE SUB MAIN
a) 2.5 sq mm cable in 20 mm conduit
b) 4.0 sq mm cable in 20 mm conduit
c) 6.0 sq mm cable in 20 mm conduit
d) 10.0 sq mm cable in 25 mm conduit
e) 16.0 sq mm cable in 25 mm conduit
f) 25.0 sq mm cable in 32 mm conduit
g) 35.0 sq mm cable in 32 mm conduit
3 1/2 WIRE SUB MAIN
a) 3 x 2.5 + 1 x 1.5 sq mm cable in 20 mm conduit
b) 3 x 4.0 + 1 x 2.5 sq mm cable in 25 mm conduit
c) 3 x 6.0 + 1 x 4.0 sq mm cable in 25 mm conduit
d) 3 x 10.0 + 1 x 6.0 sq mm cable in 25 mm conduit
e) 3 x 16.0 + 1 x 10.0 sq mm cable in 32 mm conduit
f) 3 x 25.0 + 1 x 16.0 sq mm cable in 40 mm conduit
g) 3 x 35.0 + 1 x 16.0 sq mm cable in 40 mm conduit
4 WIRE SUB MAIN
a) 2.5 sq mm cable in 20 mm conduit
b) 4.0 sq mm cable in 25 mm conduit
c) 6.0 sq mm cable in 25 mm conduit
d) 10.0 sq mm cable in 25 mm conduit
e) 16.0 sq mm cable in 32 mm conduit
f) 25.0 sq mm cable in 40 mm conduit
g) 35.0 sq mm cable in 40 mm conduit
Unit
Rate(Rs)
Metre
Metre
Metre
Metre
Metre
Metre
Metre
177
193
236
314
412
589
744
Metre
Metre
Metre
Metre
Metre
Metre
Metre
195
235
271
396
543
790
1031
Metre
Metre
Metre
Metre
Metre
Metre
Metre
209
267
324
453
661
1004
1239
Metre
Metre
Metre
Metre
Metre
Metre
Metre
217
277
339
514
711
1075
138623
SOR ELECTRICAL 2014/CHAPTER-20
Page 23 of 114
CHAPTER - 21
SUB-MAIN IN CONCEALED STEEL CONDUIT IN COPPER CONDUCTOR
S.No
Description of Item
21
Wiring for sub-mains with PVC insulated cable FR with
copper multi strand conductor ISI marked
in recessed /
concealed
rigid steel ISI marked conduit of suitable
size(Conduit included) including accessories long neck
threaded type, connection painting etc ,as required as per
specification
2 WIRE SUB MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 20 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 25 mm conduit
16.0 sq mm cable in 25 mm conduit
25.0 sq mm cable in 32 mm conduit
35.0 sq mm cable in 40 mm conduit
3 WIRE SUB MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 25 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 40 mm conduit
35.0 sq mm cable in 50 mm conduit
3 1/2 WIRE SUB MAIN
3 x 2.5 + 1 x 1.5 sq mm cable in 20 mm conduit
3 x 4.0 + 1 x 2.5 sq mm cable in 25 mm conduit
3 x 6.0 + 1 x 4.0 sq mm cable in 25 mm conduit
3 x 10.0 + 1 x 6.0 sq mm cable in 25 mm conduit
3 x 16.0 + 1 x 10.0 sq mm cable in 32 mm conduit
3 x 25.0 + 1 x 16.0 sq mm cable in 40 mm conduit
3 x 35.0 + 1 x 16.0 sq mm cable in 50 mm conduit
4 WIRE SUB MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 25 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 40 mm conduit
35.0 sq mm cable in 50 mm conduit
21.1
21.1.1
21.1.2
21.1.3
21.1.4
21.1.5
21.1.6
21.1.7
21.2
21.2.1
21.2.2
21.2.3
21.2.4
21.2.5
21.2.6
21.2.7
21.3
21.3.1
21.3.2
21.3.3
21.3.4
21.3.5
21.3.6
21.3.7
21.4
21.4.1
21.4.2
21.4.3
21.4.4
21.4.5
21.4.6
21.4.7
Unit
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Rate(Rs)
189
209
258
331
425
607
857
211
259
306
410
597
897
1200
225
281
338
457
679
1041
1336
235
291
353
492
728
1098
148324
SOR ELECTRICAL 2014/CHAPTER-21
Page 24 of 114
CHAPTER - 22
SUB MAINS IN SURFACE PVC CONDUIT IN COPPER CONDUCTOR
S.No
Description of Item
22
Wiring for sub-mains with PVC insulated cable FR with
copper multi strand conductor ISI marked in surface rigid
PVC conduit (MMS) ISI marked of suitable size(Conduit
included) including 2mm thick accessories, connection etc
,as required as per specification
2 WIRE SUB-MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 25 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 32 mm conduit
35.0 sq mm cable in 40 mm conduit
3 WIRE SUB-MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 25 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 32 mm conduit
35.0 sq mm cable in 40 mm conduit
3 1/2 WIRE SUB-MAIN
3 x 2.5 + 1 x 1.5 sq mm cable in 25 mm conduit
3 x 4.0 + 1 x 2.5 sq mm cable in 25 mm conduit
3 x 6.0 + 1 x 4.0 sq mm cable in 25 mm conduit
3 x 10.0 + 1 x 6.0 sq mm cable in 32 mm conduit
3 x 16.0 + 1 x 10.0 sq mm cable in 40 mm conduit
3 x 25.0 + 1 x 16.0 sq mm cable in 40 mm conduit
3 x 35.0 + 1 x 16.0 sq mm cable in 40 mm conduit
4 WIRE SUB-MAIN
2.5 sq mm cable in 25 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 32 mm conduit
16.0 sq mm cable in 40 mm conduit
25.0 sq mm cable in 40 mm conduit
35.0 sq mm cable in 40 mm conduit
22.1
22.1.1
22.1.2
22.1.3
22.1.4
22.1.5
22.1.6
22.1.7
22.2
22.2.1
21.2.2
21.2.3
21.2.4
21.2.5
21.2.6
21.2.7
22.3
22.3.1
22.3.2
22.3.3
22.3.4
22.3.5
22.3.6
22.3.7
22.4
22.4.1
22.4.2
22.4.3
22.4.4
22.4.5
22.4.6
22.4.7
Unit
Rate(Rs)
Metre
Metre
Metre
Metre
Metre
Metre
Metre
93
127
143
200
336
477
668
Metre
Metre
Metre
Metre
Metre
Metre
Metre
117
159
191
271
320
678
933
Metre
Metre
Metre
Metre
Metre
Metre
Metre
141
183
222
342
580
835
1063
Metre
Metre
Metre
Metre
Metre
Metre
Metre
153
195
240
367
633
915
122025
SOR ELECTRICAL 2014/CHAPTER-22
Page 25 of 114
CHAPTER - 23
SUB-MAIN IN CONCEALED PVC CONDUIT IN COPPER CONDUCTOR
S.No
23
23.1
23.1.1
23.1.2
23.1.3
23.1.4
23.1.5
23.1.6
23.1.7
23.2
23.2.1
23.2.2
23.2.3
23.2.4
23.2.5
23.2.6
23.2.7
23.3
23.3.1
23.3.2
23.3.3
23.3.4
23.3.5
23.3.6
23.3.7
23.4
23.4.1
23.4.2
23.4.3
23.4.4
23.4.5
23.4.6
23.4.7
Description of Item
Wiring for sub-mains with PVC insulated cable FR with
copper multi strand conductor ISI marked
in recessed /
concealed rigid PVC conduit (HMS) ISI marked of suitable
size(Conduit included) including 2mm thick accessories,
connection etc ,as required as per specification
2 WIRE SUB-MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 25 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 32 mm conduit
35.0 sq mm cable in 40 mm conduit
3 WIRE SUB-MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 32 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 40 mm conduit
35.0 sq mm cable in 50 mm conduit
3 1/2 WIRE SUB-MAIN
3 x 2.5 + 1 x 1.5 sq mm cable in 20 mm conduit
3 x 4.0 + 1 x 2.5 sq mm cable in 25 mm conduit
3 x 6.0 + 1 x 4.0 sq mm cable in 25 mm conduit
3 x 10.0 + 1 x 6.0 sq mm cable in 32 mm conduit
3 x 16.0 + 1 x 10.0 sq mm cable in 32 mm conduit
3 x 25.0 + 1 x 16.0 sq mm cable in 40 mm conduit
3 x 35.0 + 1 x 16.0 sq mm cable in 50 mm conduit
4 WIRE SUB-MAIN
2.5 sq mm cable in 20 mm conduit
4.0 sq mm cable in 25 mm conduit
6.0 sq mm cable in 25 mm conduit
10.0 sq mm cable in 32 mm conduit
16.0 sq mm cable in 32 mm conduit
25.0 sq mm cable in 40 mm conduit
35.0 sq mm cable in 50 mm conduit
Unit
Rate(Rs)
Metre
Metre
Metre
Metre
Metre
Metre
Metre
111
141
172
241
376
517
708
Metre
Metre
Metre
Metre
Metre
Metre
Metre
140
172
219
351
498
728
1003
Metre
Metre
Metre
Metre
Metre
Metre
Metre
145
192
249
396
578
857
1132
Metre
Metre
Metre
Metre
Metre
Metre
Metre
153
202
264
431
627
928
127826
SOR ELECTRICAL 2014/CHAPTER-23
Page 26 of 114
CHAPTER -24
REWIRING IN EXISTING RIGID STEEL / PVC NON METALLIC CONDUIT WITH
COPPER CONDUCTOR
S.No
Description of Item
24
Rewiring in existing surface /concealed rigid steel /PVC non
metallic conduit with PVC insulated cable FR with copper
multi strand conductor ISI marked and other materials as
required including replacement of worn-out /damaged/missing
material, painting etc. complete as per specification. This shall
include all work, arrangement required for wiring but shall
exclude switch, ceiling rose fitting etc.
Light /Fan/3Pin 6AMP socket outlet on separate board /
Call Bell/ Buzzer Points :-
24.1
24.1.1
24.1.2
24.1.3
24.2
24.2.1
24.2.2
24.2.3
24.3
24.3.1
24.3.2
24.4
24.5
24.5.1
24.5.2
24.5.3
24.5.4
24.5.5
24.5.6
24.5.7
24.6
24.6.1
24.6.2
24.6.3
24.6.4
24.6.5
24.6.6
24.6.7
24.7
24.7.1
Short Point
Medium Point
Long Point
Twin Control Light Point
Short Point
Medium Point
Long Point
Circuit Wiring
2 X 1.5 Sq mm.
2 X 2.5 Sq mm.
3 Pin 5 Amp Socket Outlet Point on Same Board
2 WIRE SUB-MAIN
2 X 2.5 Sq mm
2 X 4.00 Sq mm
2 X 6.00 Sq mm
2 X 10.0 Sq mm
2 X 16.00 Sq mm
2 X 25.00 Sq mm
2 X 35.00 Sq mm
3 WIRE SUB-MAIN
3 X 2.5 Sq mm
3 X 4.0 Sq mm
3 X 6.0 Sq mm
3 X 10.0 Sq mm
3 X 16.0 Sq mm
3 X 25.0 Sq mm
3 X 35.0 Sq mm
3 1/2 WIRE SUB-MAIN
a) 3 x 2.5 + 1 x 1.5 sq mm
Unit
Rate(Rs)
Each
Each
Each
188
378
586
Each
Each
Each
218
438
674
Metre
Metre
Each
46
64
56
Metre
Metre
Metre
Metre
Metre
Metre
Metre
64
79
121
180
278
419
591
Metre
Metre
Metre
Metre
Metre
Metre
Metre
89
122
174
263
409
621
87927
Metre
105
SOR ELECTRICAL 2014/CHAPTER-24
Page 27 of 114
24.7.2
24.7.3
24.7.4
24.7.5
24.7.6
24.7.7
24.8
24.8.1
24.8.2
24.8.3
24.8.4
24.8.5
24.8.6
24.8.7
b) 3 x 4.0 + 1 x 2.5 sq mm
c) 3 x 6.0 + 1 x 4.0 sq mm
d) 3 x 10.0 + 1 x 6.0 sq mm
e) 3 x 16.0 + 1 x 10.0 sq mm
f) 3 x 25.0 + 1 x 16.0 sq mm
g) 3 x 35.0 + 1 x 16.0 sq mm
4 WIRE SUB-MAIN
4 X 2.5 sq mm
4 X 4.0 sq mm
4 X 6.0 sq mm
4 X 10.0 sq mm
4 X 16.0 sq mm
4 X 25.0 sq mm
4 X 35.0 sq mm
Metre
Metre
Metre
Metre
Metre
Metre
147
210
316
492
752
1010
Metre
Metre
Metre
Metre
Metre
Metre
Metre
114
158
228
345
541
823
115628
SOR ELECTRICAL 2014/CHAPTER-24
Page 28 of 114
CHAPTER-25
CONTROL SWITCH GEARS
S.No
Description of Item
25.1
Supplying of I.S.I. Marked Switch Fuse Unit (rewirable)
double pole conduit /cable gland entry with two earthing
terminals -16 Amps. 250 Volts
32 Amps. 250 Volts
Supplying and fixing of I.S.I. 32 Amps 240 Volts D.P. switch
flush / surface type with indicator fuse unit front operated
totally enclosed pattern ( suitable for main switch as well as
control switch for appliances ) D.P. with two earthing
terminals -Suppyling of ISI Marked Switch Fuse Unit (rewirable type )
triple pole with neutral link ,415 Volt having conduit / cable
gland entry with two earthing terminals confirming to IS :
13947(Part I & III) .
16 Amps.
32 Amps.
63 Amps.
100 Amps.
200 Amps.
320 Amps.
Supplying of ISI Marked iron clad / metal clad triple pole and
neutral switch fuse unit with two earthing terminals &
without HRC fuses -16 Amps. 415/500 Volts.
32 Amps. 415/500 Volts.
63 Amps. 415/500 Volts.
100 Amps. 415/500 Volts.
Supplying of ISI Marked Change over switches in sheet
enclosure confirming to IS : 4064 / IS : 13947 (part I & III )
with side handle operated 4 pole with two earthing
terminals
16 Amps. 415/500 Volts. (off load )
32 Amps. 415/500 Volts.(off load )
63 Amps. 415/500 Volts.(off load )
100 Amps. 415/500 Volts.(off load )
200 Amps. 415/500 Volts.( off load )
320 Amps. 415/500 Volts.( off load )
400 Amps. 415/500 Volts.( off load )
630 Amps. 415/500 Volts.( off load )
25.1.1
25.1.2
25.2
25.3
25.3.1
25.3.2
25.3.3
25.3.4
25.3.5
25.3.6
25.4
25.4.1
25.4.2
25.4.3
25.4.4
25.5
25.5.1
25.5.2
25.5.3
25.5.4
25.5.5
25.5.6
25.5.7
25.5.8
Unit
Rate
(Rs)
Each
Each
547
1371
Each
124
Each
Each
Each
Each
Each
Each
1325
1627
3385
6340
9867
12463
Each
Each
Each
Each
1325
1678
3737
6847
Each
Each
Each
Each
Each
Each
Each
Each
1944
2340
4759
9547
14141
17338
2265829
35431
SOR ELECTRICAL 2014/CHAPTER-25
Page 29 of 114
25.5.9
25.6
25.6.1
25.6.2
25.6.3
25.6.4
25.6.5
25.6.6
25.6.7
25.6.8
25.6.9
25.6.10
25.6.11
25.6.12
25.6.13
25.6.14
25.6.15
25.6.16
25.6.17
25.6.18
25.6.19
25.7
25.7.1
25.7.2
25.7.3
25.7.4
25.7.5
25.7.6
25.7.7
25.7.8
25.7.9
25.7.10
25.7.11
25.7.12
25.8
800 Amps. 415/500 Volts.( off load )
Supplying of ISI Marked On-Load Change over switches
panel mouniting type confirming to IS : 13947 (part I & III )
with front operated 4 pole, 415 V with two earthing
terminals if required.
63 Amps. (open - execution )
100 Amps. (open - execution )
125 Amps. .(open - execution )
160 Amps. (open - execution )
200 Amps. (open - execution )
250 Amps. (open - execution )
320 Amps. .(open - execution )
400 Amps. .(open - execution )
630 Amps. .(open - execution )
800 Amps. .(open - execution )
63 Amps. (With enclosure )
100 Amps.(With enclosure )
125 Amps. .(With enclosure )
160 Amps. .(With enclosure )
200 Amps. .(With enclosure )
320 Amps. .(With enclosure )
400 Amps. .(With enclosure )
630 Amps. .(With enclosure )
800 Amps. .(With enclosure )
Supplying of ISI Marked Automatic Transfer Switches
(ATS) confirming to IEC : 60947-1 & IEC : 60947-6-1 with
automatic inbuilt time delay 4 pole, 415 V with two earthing
terminals if required.
Each
44172
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
3901
5105
7654
8405
10133
13731
15631
23150
27027
40052
5516
6926
10249
11249
12898
19188
28264
32542
48230
100 Amp (open execution )
160 Amp (open execution )
200 Amp (open execution )
315 Amp (open execution )
400 Amp (open execution )
630 Amp (open execution )
100 Amp (with enclosure )
160 Amp (with enclosure )
200 Amp (with enclosure )
315 Amp (with enclosure )
400 Amp (with enclosure )
630 Amp (with enclosure )
Supplying of Two Way Centre off MCB Changeover
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
40907
53525
68075
80577
100596
124194
46075
59059
74091
87058
110614
13710230
SOR ELECTRICAL 2014/CHAPTER-25
Page 30 of 114
Switch confirming to IS:13947 (part III ) / IEC : 60947-3, 2/4
pole ,AC 240 / 415 Volt, 50 Hz
25.8.1
25 Amps, Double Pole (DP)
25.8.2
40 Amps, Double Pole (DP)
25.8.3
25 Amps, Four Pole (FP)
25.8.4
40 Amps, Four Pole (FP)
25.9
Supplying of ISI Marked Switch Disconnector Fuse (SDF),
open execution (Panel mounting cubicle type) confirming to
IS:13947 (part I & III ) 2 pole , AC -23A ,50 Hz , 415 Volt
with 2 HBC fuses complete.
29.9.1
32 Amps
29.9.2
63 Amps
29.9.3
100 Amps
29.9.4
125 Amps
25.10
Supplying of ISI Marked Switch Disconnector Fuse (SDF),
in sheet steel enclosure (Panel mounting cubicle type)
confirming to IS:13947 (part I & III ) 2 pole , AC -23A ,50 Hz ,
415 Volt with 2 HBC fuses complete.
25.10.1 32 Amps
25.10.2
63 Amps
25.10.3
100 Amps
25.10.4
125 Amps
25.11
Supplying of ISI Marked Switch Disconnector Fuse (SDF),
open execution (Panel mounting cubicle type) confirming to
IS:13947 (part I & III ) 3 pole and neutral , AC -23A ,50 Hz ,
415 Volt with 3 HBC fuses complete.
25.11.1
32 Amps
25.11.2
63 Amps
25.11.3
100 Amps
25.11.4
125 Amps
25.11.5
160 Amps
25.11.6
200 Amps
25.11.7
250 Amps
25.11.8
320 Amps
25.11.9
400 Amps
25.11.10 630 Amps
25.12
Supplying of ISI Marked Switch Disconnector Fuse (SDF),
in sheet steel enclosure (Panel mounting cubicle type)
confirming to IS:13947 (part I & III ) 3 pole and neutral , AC 23A ,50 Hz , 415 Volt with 3 HBC fuses complete.
25.12.1
25.12.2
25.12.3
25.12.4
25.12.5
25.12.6
32 Amps
63 Amps
100 Amps
125 Amps
160 Amps
200 Amps
Each
Each
Each
Each
1204
1806
2299
3602
Each
Each
Each
Each
1672
2529
4932
5673
Each
Each
Each
Each
2491
3257
6016
6208
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
1990
2733
5962
6820
7811
9591
11541
15021
18073
27831
Each
Each
Each
Each
Each
Each
3780
4591
8237
9561
10360
1274831
SOR ELECTRICAL 2014/CHAPTER-25
Page 31 of 114
25.12.7
250 Amps
25.12.8
320 Amps
25.12.9
400 Amps
25.12.10 630 Amps
25.13
Supplying of ISI Marked Direct On-Line Starters confirming
to IS : 13947-4 with suitable over load relay range and
contactor size, 415 V , 3 -Phase with two earthing terminals
25.13.1
0.75 / 1.0 / 2.0 / 3.0 / 5.0 / 7.5 HP
25.13.2
10 HP
25.14
Supplying of ISI Marked Automatic Star-Delta Starters
confirming to IS : 13947-4 with suitable over load relay range
and contactor size & timer 415 V , 3 -Phase with two
earthing terminals
25.14.1
12.5 HP
25.14.2
15.0 HP
25.14.3
20 HP
25.14.4
25 HP
25.14.5
30 HP
25.14.6
35 HP
25.14.7
50 HP
25.14.8
75 HP
25.15
Supplying & fixing of High Breaking Capacity (HBC) Fuse
Links bolted connection type as per IS : 13703 : 1993 & IEC
: 60269 :1986 with 80 kA breaking capacity of approved
make
25.15.1 20 Amp. to 32 Amp
25.15.2 36 Amp to 63 Amp
25.15.3 80 Amp to 125 Amp
25.15.4 160 Amp to 250 Amp
25.15.5 300 Amp to 315 Amp
25.15.6 400 Amp to 500 Amp
25.15.7 630 Amp
25.16
Supplying & fixing of High Breaking Capacity (HBC) Fuse
Links knife (DIN) type as per IS : 13703 : 1993 & IEC :
60269 :1986 with 80 kA breaking capacity of approved
make
25.16.1 20 Amp. to 100 Amp
25.16.2 125 Amp to 160 Amp
25.16.3 200 Amp to 315 Amp
25.16.4 350 Amp to 400 Amp
25.16.5 425 Amp to 630 Amp
25.17
Supplying & fixing of ISI marked Porcelain Rewireable type
fuse carrier & base unit of approved make & confirming to
IS: 2086-1993
Each
Each
Each
Each
15017
18416
21582
32156
Each
Each
2218
3323
Each
Each
Each
Each
Each
Each
Each
Each
7840
7886
9857
11743
12612
20336
31569
54649
Each
Each
Each
Each
Each
Each
Each
69
100
208
313
460
945
1691
Each
Each
Each
Each
Each
261
315
599
686
1051
25.17.1
25.17.2
Each
Each
11132
185
16 Amps./240 Volts
16 Amps./415 Volts or 32 Amps/240 Volts
SOR ELECTRICAL 2014/CHAPTER-25
Page 32 of 114
25.17.3
25.17.4
25.17.5
25.17.6
25.17.7
25.18
32 Amps /415 Volts
63 Amps /415 Volts
100 Amps /415 Volts
200 Amps /415 Volts
300 Amps /415 Volts
Supplying & fixing of ISI marked DMC /Nylon Fuse holder
fitting / Fuse Base for knife type HBC fuse Links of approved
make & confirming to IS:13703-2-1
Each
Each
Each
Each
Each
192
337
609
1141
1646
25.18.1
25.18.2
25.18.3
25.18.4
25.18.5
25.18.6
25.18.7
25.18.8
DMC /Nylon Fuse holder fitting 20 Amps /415 Volts
DMC /Nylon Fuse holder fitting 32 Amps /415 Volts
DMC /Nylon Fuse holder fitting 63 Amps /415 Volts
DMC /Nylon Fuse holder fitting 100 Amps /415 Volts
DMC /Nylon Fuse Base 160 Amps /415 Volts
DMC /Nylon Fuse Base 250 Amps /415 Volts
DMC /Nylon Fuse Base 400 Amps /415 Volts
DMC /Nylon Fuse Base 630 Amps /415 Volts
Each
Each
Each
Each
Each
Each
Each
Each
126
184
220
902
273
541
721
98433
SOR ELECTRICAL 2014/CHAPTER-25
Page 33 of 114
Chapter-26
BUSBAR CHAMBERS AND BUS TRUNCKING
S.No
Description of Item
26.1
Supplying of metal clad ISI Marked bus bar chamber made
of heavy gauge iron sheet complete with copper strip and
bus bar supports as per specification confirming to IS -4064
32 AMP 415 VOLTS, 4 way
60/63 AMP 415 VOLTS, 4 way
100 AMP 415 VOLTS, 4 way
200 AMP 415 VOLTS, 4 way
300 AMP 415 VOLTS, 4 way
400 AMP 415 VOLTS, 4 way
500 AMP 415 VOLTS, 4 way
Supplying, erection and testing of out door Aluminium
Sandwich bus trunking System 415V 3P 4W comprising
of Aluminium Conductor processed with Copper & TIN
plated and Class B insulated, housing fabricated with 1.5mm
thick CRCA sheet enclosure IP 65 protection duly powder
coated. Every joint should be provided with monoblock joint
and shearoff nut. The mounting bracket shall be paid
seperately, including necessary material, anchor fastner,
bolt, nut, connection etc. complete as required
for
mentioned below :630A 415V 3P 4W, 50 kA ,
800A 415V 3P 4W, 50 kA ,
1000A 415V 3P 4W, 50 kA ,
1250A 415V 3P 4W, 80 kA ,
1600A 415V 3P 4W, 80 kA ,
2000A 415V 3P 4W, 80 kA ,
Supplying, erection and testing of accessories for out door
Aluminium Sandwich bus trunking System 415V 3P 4W
comprising of Aluminium Conductor processed with Copper
& TIN plated and Class B insulated, housing fabricated with
1.5mm thick CRCA sheet enclosure IP 65 protection duly
powder coated. Every joint should be provided with mono
block joint and shear off nut including necessary material,
anchor fastener, bolt, nut, connection etc. complete as
required for mentioned below :HORIZONTAL ELBOW RH STD 630A
HORIZONTAL ELBOW RH STD 800A
HORIZONTAL ELBOW RH STD 1000A
HORIZONTAL ELBOW RH STD 1250A
26.1.1
26.1.2
26.1.3
26.1.4
26.1.5
26.1.6
26.1.7
26.2
26.2.1
26.2.2
26.2.3
26.2.4
26.2.5
26.2.6
26.3
26.3.1
26.3.2
26.3.3
26.3.4
Unit
Each
Each
Each
Each
Each
Each
Each
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
each
each
each
each
Rate
(Rs)
1862
2091
2798
6186
6994
11924
15559
21483
22044
22387
24838
29938
34954
22461
23157
28112
3091734
SOR ELECTRICAL 2014/CHAPTER-26
Page 34 of 114
26.3.5
26.3.6
26.3.7
26.3.8
26.3.9
26.3.10
26.3.11
26.3.12
26.3.13
26.3.14
26.3.15
26.3.16
26.3.17
26.3.18
26.3.19
26.3.20
26.3.21
26.3.22
26.3.23
26.3.24
26.3.25
26.4
26.4.1
26.4.2
26.4.3
26.4.4
26.4.5
26.4.6
HORIZONTAL ELBOW RH STD 1600A
HORIZONTAL ELBOW RH STD 20000A
VERTICAL ELBOW RH STD 630A
VERTICAL ELBOW RH STD 800A
VERTICAL ELBOW RH STD 1000A
VERTICAL ELBOW RH STD 1250A
VERTICAL ELBOW RH STD 1600A
VERTICAL ELBOW RH STD 2000A
TRANS FEED RH STD - BOARD 630A
TRANS FEED RH STD - BOARD 800A
TRANS FEED RH STD - BOARD 1000A
TRANS FEED RH STD - BOARD 1250A
TRANS FEED RH STD - BOARD 1600A
TRANS FEED RH STD - BOARD 2000A
ADAPTOR BOX
COPPER FLEXIBLES 630A
COPPER FLEXIBLES 800A
COPPER FLEXIBLES 1000A
COPPER FLEXIBLES 1250A
COPPER FLEXIBLES 1600A
COPPER FLEXIBLES 2000A
Supplying, erection and testing of indoor Aluminium
Sandwich bus trunking System 415V 3P 4W comprising of
Aluminium Conductor processed with Copper & TIN plated
and Class B insulated, housing fabricated with 1.5mm thick
CRCA sheet enclosure IP 55 protection duly powder coated.
Every joint should be provided with mono block joint and
shear off nut with 3 plug in provision per 3 mtr including
necessary material, anchor fastner, bolt, nut, connection etc.
complete as required for mentioned below :630A 415V 3P 4W, 50 kA ,
800A 415V 3P 4W, 50 kA ,
1000A 415V 3P 4W, 50 kA ,
1250A 415V 3P 4W, 80 kA ,
1600A 415V 3P 4W, 80 kA ,
2000A 415V 3P 4W, 80 kA ,
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
each
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
36998
39869
32795
13375
34069
34913
35756
38060
20412
25466
26733
27095
30098
32796
12463
25964
31157
36350
41543
51929
67508
20875
21499
22901
24251
30108
3499035
SOR ELECTRICAL 2014/CHAPTER-26
Page 35 of 114
26.5
26.5.1
26.5.2
26.5.3
26.5.4
26.5.5
26.5.6
26.5.7
26.5.8
26.5.9
26.5.10
26.5.11
26.5.12
Supplying, erection and testing of accessories for indoor
Aluminium Sandwich bus trunking System 415V 3P 4W
comprising of Aluminium Conductor processed with Copper
& TIN plated and Class B insulated, housing fabricated with
1.5mm thick CRCA sheet enclosure IP 55 protection duly
powder coated. Every joint should be provided with
monoblock joint and shearoff nut with 3 plug in provision per
3 mtr including necessary material, anchor fastner, bolt, nut,
connection etc. complete as required for mentioned below :TRANS FEED RH STD - BOARD 630A
TRANS FEED RH STD - BOARD 800A
TRANS FEED RH STD - BOARD 1000A
TRANS FEED RH STD - BOARD 1250A
TRANS FEED RH STD - BOARD 1600A
TRANS FEED RH STD - BOARD 2000A
HANGER WITH BRACKET AND SPRING (RISER)
HANGER SUSPANSION
END COVER
PLUG-IN BOX 125A IP55 EMPTY
PLUG-IN BOX 160A IP55 EMPTY
PLUG-IN BOX 250A IP55 EMPTY
each
each
each
each
each
each
each
each
each
each
each
each
20412
25466
26733
27095
30098
32796
3523
339
12243
19860
19918
4523036
SOR ELECTRICAL 2014/CHAPTER-26
Page 36 of 114
CHAPTER – 27
MCCBs, ISOLATORS, MCBs, RCBOs, MCB DBs
Description of Item
S.No
27.1
27.1.1
27.1.1.1
27.1.2
27.1.2.1
27.1.2.2
27.1.2.3
27.1.2.4
27.1.3
27.1.3.1
27.1.3.2
27.1.3.3
27.1.3.4
27.1.3.5
27.1.3.6
27.1.4
27.1.4.1
27.2
27.2.1
27.2.1.1
27.2.1.2
27.2.1.3
Supplying of ISI Marked and approved make of Moulded
Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole,
50 Hz, 415 Volts, AC supply with respective interrupting
capacity (KA) at 415 Volts cited against their range standard
conforming to IS – 8828
MCCB with Breaking Capacity 10 KA at 415 V
Current Rating -25 to100 Amps
MCCB with Breaking Capacity 25 KA at 415 V
Current Rating -25 to100 Amps & 80% -100% adjustable
Current Rating -125 Amps & 80% -100% adjustable
Current Rating -160 Amps & 80% -100% adjustable
Current Rating -200 Amps & 80% -100% adjustable
MCCB with Breaking Capacity 35 KA at 415 V
Current Rating -160 Amps & Adjustable: 80% -100%
thermal
Current Rating -200 Amps & Adjustable: 80% -100%
thermal
Current Rating -250 Amps & Adjustable: 80% -100%
thermal
Current Rating -315 Amps & Adjustable: 80% -100%
thermal
Current Rating -400 Amps & Adjustable: 80% -100%
thermal
Current Rating -500/630 Amps & Adjustable: 80% -100%
thermal
MCCB with Breaking Capacity 50 KA at 415 V
Current Rating -800 Amps & Adjustable: 70% -100%
thermal & 4-10 times magnetic setting
Supplying of ISI Marked and approved make of Moulded
Case Circuit Breaker (MCCB) Micro-Processor Release
( current setting for overload & short circuit ) suitable for 3
phase & Neutral, 3 pole, 50 Hz, 415 Volts, AC supply with
respective interrupting capacity (KA) at 415 Volts cited
against their range standard conforming to IS – 8828
MCCB with Breaking Capacity 25 KA at 415 V
40 & 100 Amps 3 Pole & Micro-Processor Release, over
load 40% -100% x In. & short circuit 1.5 - 8 x Ir. adjustable
160 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
250 Amps 3 Pole & Micro-Processor Release, over load
Unit
Rate
(Rs)
Each
1693
Each
Each
Each
Each
5601
7229
9879
13219
Each
10927
Each
14289
Each
16615
Each
21632
Each
24115
Each
27988
Each
45448
Each
13325
Each
Each
1733437
23831
SOR ELECTRICAL 2014/CHAPTER-27
Page 37 of 114
27.2.2
27.2.2.1
27.2.2.2
27.2.2.3
27.2.2.4
27.2.2.5
27.2.3
27.2.3.1
27.2.3.2
27.3
27.3.1
27.3.1.1
27.3.1.2
27.3.1.3
27.3.1.4
27.3.1.5
27.3.1.6
27.4
27.4.1
27.4.2
27.4.3
27.4.4
27.4.5
27.4.6
27.4.7
27.4.8
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
MCCB with Breaking Capacity 36 KA at 415 V
40 & 100 Amps 3 Pole & Micro-Processor Release, over
load 40% -100% x In. & short circuit 1.5 - 8 x Ir. adjustable
160 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
250 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
400 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
630 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
MCCB with Breaking Capacity 50 KA at 415 V
800 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
1250 Amps 3 Pole & Micro-Processor Release, over load
40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable
Supplying of approved make Moulded Case Circuit
Breaker (MCCB) without protection release suitable for
3 phase, 3 pole, 50 Hz, 415 Volts, AC supply standard
conforming to IS – 8828
MCCB with Breaking Capacity 36 KA at 415 V
MCCB Swtch Disconnector Rating -200 Amps 3 Pole
without protection Release
MCCB Swtch Disconnector Rating -400 Amps 3 Pole
without protection Release
MCCB Swtch Disconnector Rating -600 Amps 3 Pole
without protection Release
MCCB Swtch Disconnector Rating -200 Amps 4 Pole
without protection Release
MCCB Swtch Disconnector Rating -400 Amps 4 Pole
without protection Release
MCCB Swtch Disconnector Rating -600 Amps 4 Pole
without protection Release
Supplying of ISI Marked and approved make of Air Circuit
Breaker (ACB) with Microprocessor release with LCD
screen showing kW, kVA, PF, maximum demand with
breaking capacity of 50 kA , 4 pole , 415 Volts conforming
to IEC : 60947-2 / IS :13947-II
630 Amp,manual,fixed
800 Amp,manual,fixed
1000 Amp,manual,fixed
1250 Amp,manual,fixed
1600 Amp,manual,fixed
2000 Amp,manual,fixed
630 Amp,manual,drawout
800 Amp,manual,drawout
Each
14096
Each
17352
Each
25298
Each
30635
Each
33728
Each
56970
Each
93204
Each
11839
Each
15909
Each
18187
Each
15193
Each
20464
Each
23637
Each
Each
Each
Each
Each
Each
Each
Each
105593
107640
112884
130708
143289
15955338
129299
131803
SOR ELECTRICAL 2014/CHAPTER-26
Page 38 of 114
27.4.9
27.4.10
27.4.11
27.4.12
27.5
27.5.1
27.5.1.1
27.5.1.2
27.5.1.3
27.5.1.4
27.5.2
27.5.2.1
27.5.2.2
27.5.2.3
27.5.2.4
27.5.3
27.5.3.1
27.5.3.2
27.5.3.3
27.5.3.4
27.5.4
27.5.4.1
27.5.4.2
27.5.4.3
27.5.4.4
27.5.5
27.5.5.1
27.5.5.2
27.5.5.3
27.5.5.4
27.5.6
27.5.6.1
27.5.6.2
27.5.6.3
27.5.6.4
27.6
27.6.1
27.6.1.1
27.6.1.2
27.6.2
1000 Amp,manual,drawout
1250 Amp,manual,drawout
1600 Amp,manual,drawout
2000 Amp,manual,drawout
Supplying of ISI Marked and accepted standard of
Miniature Circuit Breaker (MCB) of 'C' series suitable for
240/415 Volts, 50 Cycle , 10 kA Value AC supply
confirming to IS : 8828 : 1996, IEC : 60898 :2002 but
without enclosures :SINGLE POLE (SP)
0.5 Amp to 5 Amp Rating
6 Amp to 32 Amp Rating
For 40 Amps. Rating only.
50 Amp to 63 Amp Rating
SINGLE POLE & NEUTRAL(SPN)
0.5 Amp to 5 Amp Rating
6 Amp to 32 Amp Rating
For 40 Amps. Rating only.
50 Amp to 63 Amp Rating
DOUBLE POLE (DP)
0.5 Amp to 5 Amp Rating
6 Amp to 32 Amp Rating
For 40 Amps. Rating only.
50 Amp to 63 Amp Rating
FOR TRIPLE POLE (TP)
0.5 Amp to 5 Amp Rating
6 Amp to 32 Amp Rating
For 40 Amps. Rating only.
50 Amp to 63 Amp Rating
FOR TRIPLE POLE & NEUTRAL(TPN)
0.5 Amp to 5 Amp Rating
6 Amp to 32 Amp Rating
For 40 Amps. Rating only.
50 Amp to 63 Amp Rating
FOUR POLE(FP)
0.5 Amp to 5 Amp Rating
6 Amp to 32 Amp Rating
For 40 Amps. Rating only.
50 Amp to 63 Amp Rating
Supplying of MCB Isolators suitable for 240/415 Volts, 50
Hz AC supply with KA value rating 10 kA of approved
make confirming to IS :13947-Part III : 1993 & IEC :609473:2001 (without enclosures ) :SINGLE POLE
40 Amps.
63 Amps.
DOUBLE POLE
Each
Each
Each
Each
137717
151322
174201
189480
Each
Each
Each
Each
304
205
447
472
Each
Each
Each
Each
843
647
994
1031
Each
Each
Each
Each
811
617
982
1022
Each
Each
Each
Each
1166
985
1483
1527
Each
Each
Each
Each
1668
1391
1991
2033
Each
Each
Each
Each
1607
1358
1923
1975
Each
Each
236
26439
SOR ELECTRICAL 2014/CHAPTER-27
Page 39 of 114
27.6.2.1
27.6.2.2
27.6.3
27.6.3.1
27.6.3.2
27.6.4
27.6.4.1
27.6.4.2
27.6.4.3
27.6.4.4
27.7
27.7.1
27.7.2
27.7.3
27.7.4
27.7.5
27.7.6
27.7.7
27.8
27.8.1
27.8.2
27.8.3
27.8.4
27.8.5
27.9
27.9.1
27.9.2
27.9.3
27.10
27.10.1
40 Amps.
63 Amps.
TRIPLE POLE
40 Amps.
63 Amps.
FOUR POLE
40 Amps.
63 Amps.
80 Amps.
100 Amps.
Supply of approved make powder coated sheet steel
encloser SPN MCB DB inclusive of Bus bar, Neutral bar,
Earth bar & two earth terminals etc. complete as per
IS:13032( exclusive of MCB & isolator )2 way single door
4 way single door
4 way Double Door IP 43 protection
6 way Double Door IP 43 protection
8 way Double Door IP 43 protection
12 way Double Door IP 43 protection
16 way Double Door IP 43 protection
Supplying of approved make TPN MCB DB Metal Double
Door IP 43 protection
with provision for FP
MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as
outgoing inclusive of Bus bar, Neutral bar, Earth bar & two
earth terminals etc. complete as per IS:13032( exclusive of
MCB & isolator ):
4 way (4+12)
4 way (8+12)
6 way (8+18)
8 way (8+24)
12 way (8+36)
Supplying of approved make Vertical TPN MCB DB Metal
Double Door IP 43 protection with provision for FP
CB/Isolator/RCCB/RCBO as incomer and SP/TP MCBs as
outgoing inclusive of Bus bar, Neutral bar, Earth bar & two
earth terminals etc. complete as per IS:13032( exclusive of
MCB & isolator )
4 way (8+12)
8 way (8+24)
12 way (8+36)
Supplying of approved make, powder coated Metal Double
Door Vertical TPN MCB DB IP 43 protection with provision
for MCCB up to 160A TP/ FP 36kA as incomer and space
for SP/TP MCBs as outgoing (without MCCB / MCBs)
inclusive of bus bar & connections etc
Each
Each
389
505
Each
Each
701
802
Each
Each
Each
Each
880
926
1052
1132
Each
Each
Each
Each
Each
Each
Each
150
905
1185
1280
1478
1794
2228
Each
Each
Each
Each
Each
2639
2961
3650
4379
6552
Each
Each
Each
7261
9250
12344
4 way without MCCB
Each
852140
SOR ELECTRICAL 2014/CHAPTER-27
Page 40 of 114
27.10.2
27.10.3
27.11
27.11.1
27.11.2
27.11.3
27.12
27.12.1
27.12.2
27.13
27.13.1
27.13.2
27.14
27.14.1
27.14.2
27.14.3
27.14.4
27.15
27.15.1
27.15.1.1
27.15.1.2
27.15.1.3
27.15.1.4
27.15.1.5
27.15.1.6
27.15.1.7
8 way without MCCB
12 way without MCCB
Supplying of approved make, powder coated Vertical Metal
Double Door TPN MCB DB IP 43 protection with provision
for MCCB upto 250A TP /4P upto 50kA as incomer and
space for SP/TP MCBs as outgoing (without MCCB/MCBs)
inclusive of busbar &connections etc
4 way without MCCB
8 way without MCCB
12 way without MCCB
Supplying & fixing of approved make Industrial type metal
plug & socket DBs (without MCB) SPN sheet encloser
(dust protected ) inclusive of 2 pole and earth metal plug
and socket and space to incorporate SP MCB complete as
per specification as required.
10 Amps
20 Amps
Supplying & fixing of ISI marked Industrial type metal plug
socket D.B.s (without MCBs) for TPN encloser three pole
and earth metal plug and socket including space
incorporating TP MCB complete as per specification as
required.
20 Amps
30 Amps
Supply & fixing of approved make Industrial type metal
plug & socket, 3 pin (2P + E) conforming to IEC : 60309 1&3 complete as per specification
10 Amps Plug only
10 Amps socket only
20 Amps Plug only
20 Amps socket only
Supplying and installing of RCBOs (Residual current
circuit breaker with overload and short circuit
protection) ISI marked complete as per I.S. standard
confirming to IEC:61009-2-1 & IS:12640-2:2001,240/415V
50 Hz with 10 kA short circuit withstand capacity for earth
leakage, overload & short circuit protection including
connection in existing enclosure in approved manner as
per specification.
DP(4 module)
2 pole 6 to 25 Amps, 30 mA sensitivity
2 pole 32 Amps, 30 mA sensitivity
2 pole 40 Amps, 30 mA sensitivity
2 pole 63 Amps, 30 mA sensitivity
2 pole 6 to 25 Amps, 100 mA sensitivity
2 pole 32 Amps, 100 mA sensitivity
2 pole 40 Amps, 100 mA sensitivity
Each
Each
10815
14341
Each
Each
Each
17233
20166
21201
Each
Each
1036
1092
Each
Each
2341
2640
Each
Each
Each
Each
145
145
159
169
Each
Each
Each
Each
Each
Each
Each
3029
3029
3783
4527
3738
3597
413841
SOR ELECTRICAL 2014/CHAPTER-27
Page 41 of 114
27.15.1.8
27.15.2
27.15.2.1
27.15.2.2
27.15.2.3
27.15.2.4
27.15.2.5
27.15.2.6
27.15.2.7
27.15.2.8
27.16
27.16.1
27.16.1.1
27.16.1.2
27.16.2
27.16.2.1
27.16.2.2
27.16.2.3
27.16.2.4
2 pole 63 Amps, 100 mA sensitivity
FP(8 module)
4 pole 16 Amps, 30 mA sensitivity
4 pole 25-32 Amps, 30 mA sensitivity
4 pole 40 Amps, 30 mA sensitivity
4 pole 63 Amps, 30 mA sensitivity
4 pole 16 Amps, 100/300 mA sensitivity
4 pole 25-32 Amps, 100/300 mA sensitivity
4 pole 40 Amps, 100/300 mA sensitivity
4 pole 63 Amps, 100/300 mA sensitivity
Supply & fixing of approved make accepted standard sheet
steel enclosure ( dust protected ) duly powder coated paint
Neutral bar suitable for MCB / RCBOs/MCCB of capacity as
required etc. complete as per specification ( exclusive of
M.C.B./ MCCB/RCBOs )
For MCB
DP/TP/FP Enclosure
FP RCBO Enclosure
For MCCB
63/100A 3P/4P Enclosure
160A 3P/4P Enclosure
250A 3P/4P Enclosure
250A ER 3P/4P Enclosure
Each
4789
Each
Each
Each
Each
Each
Each
Each
Each
4092
4223
4287
5114
4666
4505
4641
5261
Each
Each
537
910
Each
Each
Each
Each
1650
3091
5491
657542
SOR ELECTRICAL 2014/CHAPTER-27
Page 42 of 114
CHAPTER - 28
FIXING OF SFUs, DBs, BUSBAR, MCCBs, MCBs, ISOLATORs & RCBOs
Description of Item
S.No
28.1
28.1.1
28.1.2
28.1.3
28.2
28.2.1
28.2.2
28.2.3
28.3
28.3.1
Fixing of metal clad enclosure on 25 X 5 mm flat iron
clamps including supplying and fixing of clamps as
required duly embedded in masonry including cable
connection and other required material as per
specification :16 Amps SP/DP Switch /SPN DB up to 4 way
32 Amps DP switch /SPN DB up to 8 way /16 AmpTPN
DB up to 3 way per pole or 16 Amps TP or TPN switch /
16 Amps 415 V Isolator
32 Amps TP or TPN switch/ 32 Amps 415 V Isolator /
16 Amps TPN DB up to 6 way per pole /32 Amps 415
Volt bus bar 4 way
Fixing of metal clad enclosure on 25X 25 X 5 mm angle
iron clamps including supplying and fixing of clamps as
required duly embedded in masonary including cable
connection and other required material as per
specification :Fixing of 63 Amps TP or TPN main switches/ DB 63
Amps. 240/415 Volt 4 to 8 way or 63 Amps change over
switch /63 Amps 415 Volt Isolator /30 Amps 415V TPN
DB up to 6 way per pole and bus bar 4 way
Fixing of 100 Amps TP or TPN main switch or 100 Amps
change over switch /100 Amps 415 Volt Isolators and
busbar 4 way
Fixing of 200 Amps TP or TPN main switch or 200 Amps
change over switch /200 Amps 415 Volt Isolators and
busbar 4 way
Fixing of metal clad enclosure on 35X 35 X 5 mm angle
iron clamps including supplying and fixing of clamps as
required duly embedded in masonary including cable
connection and other required material as per
specification :Fixing of 300/400 Amps TP or TPN main switch or
300/400 Amps change over switch /300/400 Amps 415
Volt Isolators and bus bar 4 way
Unit
Rate
(Rs)
Each
124
Each
155
Each
172
Each
266
Each
296
Each
320
Each
57243
SOR ELECTRICAL 2014/CHAPTER-28
Page 43 of 114
28.3.2
28.4
28.4.1
28.4.2
28.5
28.5.1
28.5.2
28.5.3
28.6
Fixing of 500/600 Amps TP or TPN main switch or
500/600 Amps change over switch 500/600 Amps 415
Volt Isolators and busbar 4 way
Each
Fixing of MCB /MCCB/ Isolator in sheet steel enclosure
as required as per accepted practice, including mounting
on busbar and cable connection etc. complete (Labour
only )
MCB / Isolator SP/DP
Each
MCB /MCCB Isolator TP /TPN/FP
Each
Labour charges for fixing sheet steel enclosure, MCB
DB surface mounting type, as per accepted practice on
25x5mm flat iron clamps duly embedded in wall,cable
connection etc. complete.
FOR S.No :27.7.1 to.27.7.4
27.7.5 & 27.8.1 to 27.8.2
27.8.3 to 27.8.4 & 27.9.1
Labour charges for fixing sheet steel enclosures, MCB
DB surface mounting type,as per accepted practice on
25x25x 5 mm angle iron clamp,including supplying and
fixing of clamps duly embedded in wall,cable connection
etc. complete :-
28.7
FOR S.No :27.7.6 & 27.7.7; 27.8.5 ; 27.9.2 & 27.9.3 & 27.10.1 to
27.10.3 ; 27.11.1 to 27.11.3
Labour charges for fixing sheet steel enclosures, MCB
DB flush mounting type, as per accepted practice, duly
embedded and end plate completely flushed in wall,
cable connection etc.complete :-
28.7.1
28.7.2
FOR S.No :27.7.1 to 27.7.7 ; 27.8.1 to 27.8.3 & 27.9.1,
27.8.4 & 27.8.5 ; 27.9.2 to 27.9.3 ; 27.10.1 to 27.10.3 &
27.11.1 to 27.11.3
28.6.1
637
11
22
Each
Each
Each
135
184
201
Each
334
Each
232
Each
27144
SOR ELECTRICAL 2014/CHAPTER-28
Page 44 of 114
CHAPTER - 29
WIRING ACCESSORIES,PANELS,LAMPS,
S.No
Description of Item
29.1
Supplying and fixing as per specification Polycarbonate
pendent Holder of approved make including flexible cord up
to 3 Meter length with necessary materials complete
Supplying and fixing as per specification Polycarbonate
Batten Holder / Angle Holder of approved make with
necessary materials complete
Supplying and fixing as per specification Call bell / buzzer of
approved make with necessary materials complete.
Buzzer
Ding Dong bell
Musical bell
Remote/cordless bell
Gong bell
Supplying and fixing as per specification Modular Call bell
indicator 230 Volt A.C. including reset and buzzer of
approved make with necessary materials complete.
Bell Indicator with Reset( 1 Module) 250V
Buzzer Modular (2 Module)
Supplying and fixing of multi core round HRFR / FR PVC
insulated copper (flexible) conductor & PVC sheathed
cables 1100 Volts as per IS:694-1990 of approved make
( 16 /0.2 mm )Three core 0.5 sq.mm.
( 24 /0.2 mm ) Three core 0.75 sq.mm.
( 30 /0.25 mm ) Three core 1.5 sq.mm.
( 50 /0.25 mm ) Three core 2.5 sq.mm.
( 56 /0.3 mm ) Three core 4.0 sq.mm.
Supplying and fixing in position incandescent lamp of
approved make as per IS specification
15 Watt 250 Volt
25 Watt 250 Volt
40 Watt 250 Volt
60 Watt 250 Volt
100 Watt 250 Volt
200 Watt 250 Volt
15 Watt 250 Volt coloured lamp
Supplying and fixing as per specification Switch of approved
make ISI marked with necessary material complete.
6 Amp Flush type
20 Amp Flush type
29.2
29.3
29.3.1
29.3.2
29.3.3
29.3.4
29.3.5
29.4
29.4.1
29.4.2
29.5
29.5.1
29.5.2
29.5.3
29.5.4
29.5.5
29.6
29.6.1
29.6.2
29.6.3
29.6.4
29.6.5
29.6.6
29.6.7
29.7
29.7.1
29.7.2
Unit
Rate
(Rs)
Each
31
Each
32
Each
Each
Each
Each
Each
58
107
248
1018
93
Each
Each
272
174
Metre
Metre
Metre
Metre
Metre
23
25
41
67
107
Each
Each
Each
Each
Each
Each
Each
20
21
21
21
23
31
20
Each
Each
23
9045
SOR ELECTRICAL 2014/CHAPTER-29
Page 45 of 114
29.7.3
29.7.4
29.7.5
29.7.6
29.8
29.8.1
29.8.2
29.8.3
29.8.4
29.9
29.9.1
29.9.2
29.9.3
29.10
29.10.1
29.11
29.12
29.12.1
29.12.2
29.13
29.14
29.14.1
29.14.2
29.15
29.15.1
29.15.2
29.15.3
29.15.4
29.15.5
29.15.6
29.15.7
29.15.8
29.16
6 Amp S.P. 250 Volt two way Flush type
6/10 Amps S.P.250 Volt Modular Switch
20/16 Amps S.P.250 Volt Modular Switch
6/10 Amps S.P.250 Volt Modular Switch 2 way
Supplying and fixing as per specification socket outlet of
approved make & ISI marked with necessary material
complete
6 Amp 250 Volt 3 / 5 Pin Flush type
16 Amp 250 Volt 3 / 6 Pin Flush type
10 Amps 3 Pin Uni Modular Socket
20 / 10 Amps Twin Modular Socket
Supplying and fixing as per specification 6 Amp 250 Volt
Bell Push switch of approved make ISI marked with
necessary material complete.
6/10 Amps S.P.250 Volt Modular Switch Bell Push
Flush Type Bell Push
Surface Bell Push 6A
Supplying and fixing as per specification switch socket
combined of approved make & ISI marked with necessary
material complete
20/10 Amp 250 Volt 3 / 6 Pin Flush type
Supplying and fixing as per specification Polycarbonate
Ceiling rose 3 Plate of approved make ISI marked with
necessary material complete.
Supplying and fixing of approved make 3 pin plug top ISI
marked
6 Amp 250 Volt 3 Pin
16 Amp 250 Volt 3 Pin
Supplying and fixing as per specification Ball Socket of
approved make with necessary material complete.
Supplying and fixing as per specification Caution / Danger
Board as required of approved make & design with
necessary material complete.
Small Size
Large Size
Supplying,Fixing and Testing of MPP condensor 440 Volt
Single Phase of approved make as required as per
specification
Condensor 2.5 mfd 440V
Condensor 3.15 mfd 440 V
Condensor 4.00 mfd 440 V
Condensor 6.00 mfd 440 V
Condensor 36.00 mfd 440 V
Condensor 45.00 mfd 440 V
Condensor 50.00 mfd 440 V
Condensor 60.00 mfd 440 V
Supplying,Fixing and Testing of MPP condensor 250 Volt
Each
Each
Each
Each
31
128
190
156
Each
Each
Each
Each
44
105
207
333
Each
Each
Each
154
35
35
182
Each
22
Each
Each
61
79
Each
24
Each
Each
80
160
Each
Each
Each
Each
Each
Each
Each
Each
32
38
46
86
404
437
490
51246
SOR ELECTRICAL 2014/CHAPTER-29
Page 46 of 114
29.16.1
29.16.2
29.16.3
29.16.4
29.16.5
29.16.6
29.16.7
29.17
29.17.1
29.18
29.18.1
29.19
29.19.1
29.19.2
29.19.3
29.19.4
29.19.5
29.19.6
29.19.7
29.20
29.20.1
29.20.2
29.20.3
29.20.4
29.21
29.21.1
29.21.2
Single Phase of approved make as required as per
specification
Condensor 4 mfd 250 V
Condensor 8 mfd 250 V
Condensor 10 mfd 250 V
Condensor 15 mfd 250 V
Condensor 20 mfd 250 V
Condensor 33 mfd 250 V
Condensor 42 mfd 250 V
Supplying, Fixing and Testing of mixed die-electric ultra
heavy duty APP capacitor 440 Volt, 3 Ph., peak inrush
current upto 500 x In, over current upto 3 x In(normal
current), operating losses total not more than 0.35 W /
KVAr, operating life not less than 300000 hrs, switching
20000 operation / year, as per IS:13340-1993, IS:133411992, IS:13585-1994, of approved make as required as per
specification
5 to 25 KVAr bank
Supplying, Fixing and Testing of MPP - H heavy duty
capacitor 415 Volt, 3 Ph., peak inrush current up to 250 x
In, over current upto 1.8 x In(normal current), operating
losses total not more than 0.35 W / KVAr, switching 8000
operation / year, as per IS:13340-1993, IS:13341-1992 of
approved make as required as per specification
5 to 25 KVAr bank
Supplying,Fixing and Testing of Flourescent Tube rod ISI
marked of approved make as required as per specification
4' X 40 Watt
4' X 36 Watt
2' X 20 Watt
2' X 18 Watt
T - 5 Lamp - 14 Watt
T - 5 Lamp - 24 Watt
T - 5 Lamp - 28 Watt
Supplying,Fixing and Testing of SV lamp SON-T (tubular
clear type) ISI marked of approved make as required as
per specification
70 Watt
150 Watt
250 Watt
400 Watt
Supplying, Fixing and Testing of MH lamp Single ended
type ISI marked of approved make as required as per
specification
70 Watt
150 Watt
Each
Each
Each
Each
Each
Each
Each
58
78
107
136
175
234
307
P KVAr
633
P KVAr
390
Each
Each
Each
Each
Each
Each
Each
50
50
45
48
125
166
133
Each
Each
Each
Each
444
577
643
754
Each
Each
832
94247
SOR ELECTRICAL 2014/CHAPTER-29
Page 47 of 114
29.21.3
29.21.4
29.22
29.22.1
29.22.2
29.23
29.23.1
29.23.2
29.23.3
29.23.4
29.23.5
29.23.6
29.23.7
29.23.8
29.23.9
29.23.10
29.23.11
29.24
29.24.1
29.24.2
29.24.3
29.24.4
29.24.5
29.24.6
29.25
29.25.1
29.25.2
29.26
29.26.1
29.26.2
29.26.3
29.26.4
29.27
29.28
29.29.1
250 Watt
400 Watt
Supplying, Fixing and Testing of MH lamp Double ended
type ISI marked of approved make as required as per
specification
70 Watt
150 Watt
Supplying, Fixing and Testing of Compact Fluorescent
Lamp (CFL) with inbuilt electronic ballast ISI marked BC /
ES cap of approved make as required as per specification
5 Watt
8 Watt
11 Watt
15 Watt
18 Watt
20 Watt
23 Watt
26 Watt
45 Watt
65 Watt
85 Watt
Suppling,Fixing and Testing of Compact ,Fluorescent Lamp
Non-Retrofit ISI marked of approved make as required as
per specification
9 Watt, 2Pin /4 Pin
11 Watt, 2Pin / 4 Pin
13 Watt, 2Pin
18 Watt, 2Pin / 4 Pin, D Type
18 Watt, 4Pin / 4 Pin, L Type
36 Watt, 4Pin L Type
Supplying, Fixing and Testing of Halogen Rod of approved
make as required as per specification
500 Watt
1000 Watt
Supplying, Fixing and Testing of Ball Bearing of approved
make as required as per specification
6201
6202
6203
6204
Supplying and fixing of approved make Resistance type
Fan regulator including connection etc. as required on
existing board
Supplying and fixing of approved make step type electronic
Fan regulator including connection etc. as required on
existing board
100 Watt (socket type)
Each
Each
1083
1090
Each
Each
643
665
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
161
166
177
194
227
227
255
288
604
721
832
Each
Each
Each
Each
Each
Each
107
113
142
148
175
180
Each
Each
99
110
Each
Each
Each
Each
138
150
163
200
Each
84
Each
29148
SOR ELECTRICAL 2014/CHAPTER-29
Page 48 of 114
29.30
29.30.1
29.30.2
29.31
Supplying and fixing of approved make electronic dimmer /
regulator including connection etc. as required on existing
board
450 Watt
1000 Watt
Supplying and fixing of approved make step type Modular
electronic Fan regulator including connection etc. as
required on existing board
Each
Each
228
390
29.31.1
29.31.2
29.32
100 Watt (1 Module)
100 Watt (2 module)
Supplying and fixing of approved make step type Modular
electronic dimmer including connection etc. as required on
existing board
Each
Each
574
689
29.32.1
29.32.2
650 Watt (1 Module)
Each
1000 Watt (2 module)
Each
Locking arrangement for Switch Gear Mounting
Supplying, fixing, testing & commissioning wall / floor
mounted LT Panel primer coated with powder coated paint
& provided with required gasket for dust / vermin proof with
degree of protection IP42 suitable for 415V 3 phase, 50 Hz,
4 wire system fabricated out of CRCA sheet up to 2 mm
thick (1.6 mm for doors) duly compartmentalized for
incomer, bus section, outgoings, cable alleys & CT, PT
Ampere Meter, Volt Meter, selector switches, Frequency
Meter, phase indicating lamps, Energy Meter complete
including cost of busbar supports, detachable cable gland
plates, 2 earthing terminals, internal wiring & fixing of
separately supplied MCBs, MCCBs , ACB, panel mounted
Changeover switch / SFUs, etc. as required but excluding
cost of bus bar strips, Ampere Meter, Volt Meter, Selector
switch as per approved design & specification
Kg
Supplying and fixing of LT Panel accessories of approved
make in existing LT Panel including connections etc.as
required as per spececification
567
842
29.33
29.34
29.34.1
29.34.2
29.34.3
29.34.4
29.34.5
Digital Ampere Meter with CTs with selector switch
Digital Volt Meter with selector switch & HRC fuse
Frequency Meter
Copper Bus bar strips with PVC sleeves
Aluminium bus bar strips with PVC sleeves
29.34.6
LED lamp indicator
180
per set
per set
Each
Kg
1950
2100
1200
650
Kg
each
250
20049
SOR ELECTRICAL 2014/CHAPTER-29
Page 49 of 114
CHAPTER - 30
FAN
S.No
Description of Item
30.1
Supplying, erection and testing of approved make electric
Ceiling fan of double ball bearing complete with standard
down rod, canopy, hanging shackle, Aluminium blades,
without regulator, A.C. 230-250 volts including connections
with all necessary material complete of approved as required
confirming to IS :374/1979 with up to date ammendments.
Unit
Rate
(Rs)
30.1.1
30.1.2
30.1.3
30.2
Ceiling Fan (5 star & ISI)-1200 mm Sweep
Each
Ceiling Fan Ornamental (5 star)-1200 mm Sweep
Each
Ceiling Fan ( ISI )-1400 mm Sweep
Each
Supplying, erection and testing of approved make Wall
Mounting fan complete with Wall Bracket ,canopy, blades,
speed Regulator etc .A.C 230-250 volts with connections and
including raw bolt/Anchor hole fastener etc. complete finished
of approved as required.
2276
2690
2619
30.2.1
30.2.2
30.3
300 sweep
400 sweep
Supplying, erection and testing of approved make Cabin fan
oscillating type with base, blades, guard, etc. AC 230-250
volts with connections and including raw bolt/Anchor hole
fastener etc. complete finished and as required.
Each
Each
2198
2771
30.3.1
30.4
300 sweep
Supplying, erection and testing of approved make 'Fresh Air
Fan' AC 230-250 volts with connection and including frame
bolt/Anchor hole fasteners etc. complete finished of approved
as required.
150mm sweep
225mm sweep
300mm sweep
Supplying and fixing of Deluxe fresh air fan with louvers (
ventilating fan ) with self closing louvers of decorative PVC
blades mounting square frame of approved make complete
with all necessary material as required
Each
2201
Each
Each
Each
1264
1368
1437
150mm
200mm
250mm
300mm
Each
Each
Each
Each
1483
1599
1669
179650
30.4.1
30.4.2
30.4.3
30.5
30.5.1
30.5.2
30.5.3
30.5.4
RPM1300/1400
RPM1300/1400
RPM1300/1400
RPM1300/1400
SOR ELECTRICAL 2014/CHAPTER-30
Page 50 of 114
30.6
Supplying, erecting and testing of approved make Exhaust
Fan heavy duty with mounting frame, blades AC 230-250
complete connection and including, frame bolt/ Anchor hole
fastners etc. complete finished of approved as required.
30.6.1
30.6.2
30.6.3
30.6.4
30.7
300mm sweep 900 RPM
380mm sweep 900 RPM
450mm sweep 900 RPM
600mm sweep 900 RPM
Supplying and testing of approved make Pedestal fan A.C.
230-250 volts with blades, inbuilt speed regulator, adjustable
height etc duly wired with all necessary material complete of
approved as required
30.7.1
30.8
400 mm Sweep
Supplying and testing of approved make Air Circulator fan
A.C. 230-250 volts with blades etc duly wired with all
necessary material complete of approved as required as
mentioned below:
30.8.1 Air circulator Wall mounting
30.8.1.1 450 mm Sweep inbuilt speed regulator
30.8.1.2 600 mm Sweep
30.8.2 Air circulator Pedestal Adjustable height
30.8.2.1 450 mm Sweep inbuilt speed regulator
30.8.2.2 600 mm Sweep
30.9
supplying and replacement of cooler fan 500 mm (20") ISI
marked with all necessary material including connection
complete of approved as required
30.10
30.11
Each
Each
Each
Each
2918
3450
4723
7349
Each
2979
Each
Each
6077
7176
Each
Each
6768
8388
Each
2073
supplying and replacement of cooler submersible water
pump complete with all necessary material including
connection of approved as required
Each
Supplying and fixing of cooler / A.C. MS angle iron stand
including flat iron supports, including grouting in wall, if
required, welding and painting with primer and two coat of
superior quality paint complete.
Kg
581
8051
SOR ELECTRICAL 2014/CHAPTER-30
Page 51 of 114
CHAPTER - 31
LUMINAIRES
Description of Item
S.No
31.1
31.1.1
31.2
31.2.1
31.3
31.3.1
31.3.2
31.3.3
Fluorescent Tube Fitting
Supplying, fixing & testing of approved make of T- 5 lamp
channel luminaries with plastic extruded housing with
in-built electronic control gear, decorative end caps,
diffuser including necessary materials connection etc.
complete as required (without lamp)
T - 5 Lamp 1 X 14 watt
Supplying fixing and testing of T- 5 lamp Batten type Tube
fitting with epoxy white powder coated CRCA sheet steel
complete with electronic ballast (HF), rotor holders, duly
wired ( without tube rod ) fixing wall/ceiling on PVC
clamp/round plate with necessary materials complete as
required.
T - 5 Lamp 1 X 28 watt
Supplying, fixing & testing of approved make T- 5 lamp
channel luminary with epoxy white powder coated
CRCA sheet steel housing box type channel with
reflector cover including electronic ballast (HF), PF > 0.95,
THD <30% complete duly wired (with tube rod) as per
specification & fixing as below:
I) Fixing on wall/Ceiling on PVC plate Anchor fasteners
and other necessary materials including connections etc.
and as required.
II) Fixing by stiff pendant arrangement with two pieces of
steel conduit 19/20 dia 16 SWG and other necessary
materials such as ball socket, wooden round block with 'J'
hook/Anchor hole fasteners fixed in Ceiling including
connection and as required for length upto 1.5 Meter
III) Fixing by pendant arrangement with two pieces of
approved metallic chain and other necessary materials
such as wooden block with 'J' hook Anchor hole fastner
fixed in Ceiling including connection as required for length
up to 1.5Metre
T-5 Mirror Optics -Surface Mounted
Unit
Rate
(Rs)
535
Each
535
Each
1172
Each
1360
Each
124752
SOR ELECTRICAL 2014/CHAPTER-31
Page 52 of 114
31.4
31.4.1
31.4.1.1
31.4.1.2
31.4.2
31.4.2.1
31.4.2.2
31.5
31.5.1
31.5.2
31.6
31.7
Supplying, fixing and testing of approved make surface
mounting mirror optics luminaries for single/twin 28 watt T5 fluorescent lamp comprising of white powder coated
CRCA sheet steel housing raw silk / navy brown / white
colour M.S. low profile flat housing complete with all
accessories i.e. electronic ballast (HF), PF > 0.95, THD
<30%, duly wired (without tube rod) and high purity
anodized aluminium reflector assembly along with cross
louvers as per specification and fixing as below.
Fixing on wall/Ceiling on wooden round block with 'J'
hook/Anchor hole fastener fixed in Ceiling and other
necessary materials including connections etc. and as
required.
1x28w
2x28w
Fixing by stiff pendant arrangement with two pieces of
steel conduit 19/20mm dia 16 SWG and other necessary
materials such as ball socket, T.W. block with 'J' hook/
Anchor hole fastener fixed in Ceiling including connections
and as required for length up to 1.5 Meter.
1x28w
2x28w
T-5 Mirror Optics (recessed/concealed)
Supplying, fixing and testing of approved make recess
mounting mirror optics luminaries for single/twin 28 watt
fluorescent lamp comprising of white powder coated CRCA
sheet steel housing raw silk / navy brown / white colour
M.S. low profile flat housing complete with all accessories
i.e.electronic ballast (HF), PF > 0.95, THD <30%, duly
wired (without tube rod) and high purity anodized
aluminium reflector assembly along with cross louvers as
per specification and fixing .
1x28w
2x28w
BULK HEAD
Supplying, fixing and testing of approved make bulk head
luminary consisting of pressure die aluminium housing
lamp holder, prismatic glass cover, rubber gasket and wire
guard, deluxe type, including fixing on wall as required,
with necessary material complete Fitting suitable for
Retrofit 10W CFL / GLS Lamp
Supplying, fixing and testing of approved make modular
integral step / skirt LED light suitable for 3 module box and
plate including fixing on wall as required, with necessary
material complete
Street Lights
2463
3584
2651
3772
2302
3584
Each
594
Each
66853
SOR ELECTRICAL 2014/CHAPTER-31
Page 53 of 114
31.8
31.8.1
31.8.2
31.8.3
31.9
31.9.1
31.9.2
31.9.3
31.9.4
31.10
31.10.1
31.10.2
31.10.3
31.10.4
H.P. SV / MH Fitting
Supplying, fixing & testing of approved make H.P. SV /
MH fitting consisting of single piece sheet aluminium alloy
deep drawn housing highly polished anodized aluminium
reflector clear acrylic cover, gasket and equipped with
accessories; such as ballast, condensor, ignitor, skirted
ceramic lamp holder (without lamp) suitable for end
mounting duly wired, including fixing with 32/38 mm dia
G.I. pipe Light 'A' class of required length upto 2 Meter for
mounting on wall/existing pole/on existing D bracket
including bending the pipe to required shape and
connections including all materials as required
70 watt
150 watt
250 watt
Supplying ,fixing and testing of approved make of
H.PSV/MH side road lighting/ main road lighting lantern
consisting of single piece cast aluminium housing
complete with all accessories suitable for tubular 70W
/15OW /250W/HPSV / HPMH lamp pot type high purity
electromechanically brightened anodized aluminium
reflector/ with ripples embossing above the lamp, lamp
holder, clear toughend glass cover & 3/5 stainless steel
toggle, ignitor & ballast, condensor (without lamp) i/c fixing
with 32/38 mm dia G.I. pipe Light 'A' class of required
length upto 2 mtr. for mounting on wall/existing pole/on
existing "D" bracket i/c bending the pipe to required shape
and connections, i/c all material as required & suitable for:
70 Watt
150 Watt
250 Watt
400 Watt
Flood Lighting
Supplying, fixing & testing of approved make of integral
type SV / MH compact flood light fitting consisting of cast
aluminium housing complete with all accessories such as
aluminium reflector, lamp holder heat resisting toughned
clear glass cover and mounting bracket with aiming disc,
including fixing & connections as required position with all
necessary materials required, suitable for single / double
ended lamp (without lamp)
70 Watt S.V./ M.H. Lamp ( Tubular Lamp)
70 Watt metal halide Lamp (Double ended)
150 Watt S.V./ M.H. Lamp ( Tubular Lamp)
150 Watt metal halide Lamp (Double ended)
Each
Each
Each
4753
6014
7703
Each
Each
Each
Each
5433
7217
9220
10998
Each
Each
Each
Each
5664
5632
7269
683054
SOR ELECTRICAL 2014/CHAPTER-31
Page 54 of 114
31.10.5
31.10.6
31.11
31.11.1
31.11.2
31.11.3
31.11.4
31.12
31.12.1
31.12.2
31.12.3
31.12.4
31.12.5
31.12.6
31.13
31.13.1
31.13.2
31.13.3
250 Watt S.V./ M.H. Lamp ( Tubular Lamp)
400 Watt S.V./ M.H. Lamp ( Tubular Lamp)
Supplying, fixing & testing of approved make H.D.
asymmetrical / symmetrical beam flood light fitting suitable
for tubular single lamp consisting of cast aluminium
housing aluminium faceted reflector assly toughned glass
cover, mounting bracket and aiming disc, seperate control
gear box required for HPSV/M.H. Lamp (without lamp)
including fixing & connection as required in position with all
necessary material required
1 X 250 watt S.V. Lamp/Metal Halide with control gear
box.
1 X 400 Watt S.V. Lamp/metal Halide with control gear
box
1 X 400 Watt S.V. Lamp/metal Halide with control gear
box symmetrical
2 X 400 Watt S.V. Lamp/metal Halide with control gear
box
POST TOP LANTERNS
Supplying, fixing & testing of approved make of integral
type decorative post top lantern consisting of aluminium
canopy opal / clear acrylic bottom cover and cast
aluminium spigot complete with all accessories and control
gear box (without lamp) including fixing on gate pillers/
existing G.I. pipe, pole with connection and all required
material on required size of G.I. pipe, suitable for 1 X 18 Watt CFL (Opal)
1 X 18 Watt CFL (Clear)
2 X 18 Watt CFL (Opal)
2 X 18 Watt CFL (Clear)
For 1 x 45W Retrofit CFL (Without control gear)
LED 40 Watt
Supplying, fixing & testing of approved make globe type
polycarbonate post top lantern, consisting of cast
aluminium spigot complete with all accessories, lamp
holder, ( without lamp) including fixing on gate
Pillers/exiting G.I. pipe, pole with connection & all required
materials on existing required size of G.I. pipe, suitable
CFL for mentioned below sizes :200 mm ( 8" ) dia.
250 mm ( 10" ) dia.
300 mm ( 12" ) dia.
Each
Each
9053
10496
Each
9053
Each
11040
Each
12567
Each
22410
Each
Each
Each
Each
Each
Each
3145
4003
5666
6744
4652
1205
1596
225055
SOR ELECTRICAL 2014/CHAPTER-31
Page 55 of 114
31.14
31.14.1
31.14.2
31.14.3
31.15
31.15.1
31.15.2
31.15.3
31.15.4
31.15.5
31.16
31.16.1
31.16.2
31.16.3
31.16.4
31.16.5
31.17
Supplying, fixing & testing of approved make of integral
type bollard cyclindrical shape housing cast aluminium
dome shape top cover fixed with cylindrical shape poly
carbonate cover having base plate with holes for direct
mounting complete with all accessories and control gear
box (without lamp) including preparatoion of foundation
including fixing with connection and all required material as
required.
2 X 18 Watt CFL Height > 700mm
LED 9 Watt Height > 700mm
LED 9 Watt Mashroom shape Height > 600mm
LOW WATT MOUNTINGS
Supplying, fixing & testing of approved make of low watt
surface mounting luminaires, made of white powder
coated CRCA sheet steel housing with aluminium mirror
reflector complete with electronic ballast (HF), PF > 0.95,
THD <30% , wired upto terminal block on a detachable
tray including fixing on wall/ Ceiling on wooden round block
including wiring & connection as required and suitable for
CFL as follow :- (without lamp)
2 nos. 11 watt CFL aluminium mirror reflector
2 no. 18 watt CFL aluminium darklight reflector( P 5
Louvers )
2 Nos 36 watt CFL (597 mm X 597 mm ) aluminium
darklight reflector( P 5 Louvers )
3 Nos 36 watt CFL (597 mm X 597 mm ) aluminium
darklight reflector( P 5 Louvers )
2 Nos 36W CFL Clean room clear acrylic cover
Supplying, fixing & testing of approved make of low watt
recessed mounting luminary made of CRCA sheet steel
housing with false Ceiling clips, finished in stove enameled
white inside/outside fitted with high purity anodized
aluminium mirror reflector and complete with electronic
ballast (HF), PF > 0.95, THD < 30%, including fixing with
recessed mounting arrangement with necessary materials
connection etc. complete as required and suitable for
twin/three CFL as follows :-(without lamp)
2 nos. 18 watt CFL aluminium mirror reflector
2 nos. 36 watt CFL aluminium reflector
2 Nos 36 watt CFL (597 mm X 597 mm ) aluminium
darklight reflector( P 5 Louvers )
3 Nos 36 watt CFL (597 mm X 597 mm ) aluminium
darklight reflector( P 5 Louvers )
2 Nos 36W CFL Clean room clear acrylic cover
Supplying, fixing & testing of approved make low watt
9478
9214
9702
Each
1756
Each
2492
Each
4438
Each
Each
4628
7629
Each
Each
1376
2777
Each
3964
Each
Each
4486
705956
SOR ELECTRICAL 2014/CHAPTER-31
Page 56 of 114
31.17.1
31.18
31.18.1
31.18.2
31.19
31.19.1
31.19.1
31.20
31.20.1
31.21
32.21.1
31.21.2
surface mounting CFL down lighter luminaire with white
powder coated CRCA aluminium cover & opal acrylic
cover, wired with electronic ballast (HF), PF > 0.9
including necessary materials connection etc. complete as
required for mentioned below :- (without lamp)
CFL 2 X 18 watt
Supplying, fixing & testing of approved make low watt
recessed
mounting horizontal CFL down lighter
luminaire with white powder coated CRCA ring including
spring loaded adjustable mounting bracket & Satin brite Matt finish aluminium reflector, wired with suitable
electronic ballast (HF), PF > 0.9, including necessary
materials connection etc. complete as required
for
mentioned below :- (without lamp)
CFL 1 X 18 watt
CFL 2 X 18 watt
Supplying, fixing & testing of approved make of low watt
CFL roadway / street light luminary with epoxy powder
coated sheet aluminium / steel housing with epoxy white
powder coated CRCA sheet steel gear tray, electronic
ballast (HF), PF > 0.95, THD <30%, clear acrylic cover
with necessary materials connection including mounting
with GI pipe Light 'A' class 25/32mm OD, clamps on
existing wall / pole etc. complete as required (without
lamp)
CFL 1 X 18 watt
CFL 1 X 36 watt
Supplying, fixing & testing of approved make CFL street
light fitting consisting of metallic sheet aluminium alloy
housing, highly polished aluminium reflector clear acrylic
cover, gasket and equipped with accessories; such as
lamp holder (without lamp) suitable for end mounting duly
wired, including fixing with 32/38 mm dia G.I. pipe LIght 'A'
class of required length upto 2 Meter for mounting on
wall/existing pole/on existing D bracket including bending
the pipe to required shape and connections including all
materials as required
Up to 85 watt CFL
Supplying, fixing & testing of approved make of low watt T5 Lamp roadway / street light luminary with epoxy
powder coated sheet steel / Aluminum housing with epoxy
white powder coated CRCA sheet steel gear tray ,
electronic ballast (HF), PF > 0.95, THD <30% , clear
acrylic cover with necessary materials connection including
mounting with GI pipe Light 'A' class 32/38 mm dia, clamps
on existing wall / pole etc. complete as required (without
lamp)
T - 5 Lamp 2 X 24 watt
T - 5 Lamp 4 X 24 watt
Each
2444
Each
Each
1067
1352
Each
Each
1704
1941
Each
2253
3535
752357
SOR ELECTRICAL 2014/CHAPTER-31
Page 57 of 114
31.22
31.22.1
31.22.2
31.22.3
31.22.4
31.23
31.24
31.24.1
31.24.2
31.24.3
31.25
LED LIGHTING
Supply and fixing Led tube rod comprising of LED tube
with non integral / integral driver, 6500K color temp having
40000 burning hrs life with minimum @ L 70, system
lumen output should be minimum with efficacy > 80 lm/W.
LED driver PF 0.95 & THD < 20%. The colour rendering
index of LED light should be more than 70. Submission LM
80-08 Form LED Source Manufacturer & LM79-08 /
IS16106 from NABL approved lab. Manufacturer
mandatory i/c connection wire, testing etc. to complete the
job. 2 Yrs Guarantee certificate from manufacturer.
1 X 5/8W Integral Tube fitting complete
1 X 18/20/22W, Integral
1 X 18/20/22W, Non Integral with driver
LED Retrofit tube only 18/20/22W 3 - 6K without box
suitable for replacing existing 36/40W FTL
Supply & fixing Mounting rail / Batten made of CRCA
powder coated with suitable lamp holding brackets for LED
Tube rod 1200mm Single on wall / ceiling including
connection testing etc complete as required.
Supply and fixing of recessed mounting type Led light
fixture, LED of 1 to 3 W each assembled on single
MCPCB, having color temp 6500K & having 50000
burning hrs life with minimum @ L 70, system lumen
output should be minimum with efficacy>80lm/W. LED
driver, PF 0.95 & THD < 20%. The colour rendering index
of LED light should be more than 70. Housing made of
CRCA with glare free diffused polycarbonate cover.
Submission LM 80-08 Form LED Source Manufacturer &
LM79-08 / IS16106 from NABL approved lab.
Manufacturer manadatory i/c connection wire, testing etc.
to complete the job. 2 Yrs Guarantee certificate from
manufacturer.
Led luminiare 1' X 1', 24W , 4-6.5k
Each
Led luminiare 2' X 2', 36W, 4-6.5K
Each
Led luminiare 2' X 2', 45W, 4-6.5K
Each
Supply and fixing of surface mounting type Led light
fixture, LED of 1 to 3 W each assembled on single
MCPCB, having color temp 6500K & having 50000
burning hrs life with minimum @ L 70, system lumen
output should be minimum with efficacy>80lm/W. LED
driver, PF 0.95 & THD < 20%. The colour rendering index
of LED light should be more than 70. Housing made of
CRCA with glare free diffused polycarbonate cover.
Submission LM 80-08 Form LED Source Manufacturer &
LM79-08 / IS16106 from NABL approved lab.
Manufacturer manadatory. i/c connection wire, testing etc.
to complete the job. 2 Yrs Guarantee certificate from
manufacturer.58
1620
2208
3067
2515
669
4753
9811
10226
SOR ELECTRICAL 2014/CHAPTER-31
Page 58 of 114
31.25.1
31.25.2
31.25.3
31.26
31.26.1
31.26.2
31.26.3
31.27
31.27.1
31.27.2
31.27.3
31.28
31.28.1
31.29
Led luminiare 1' X 1', 24W , 4-6.5k
Led luminiare 2' X 2', 36W , 4-6.5k
Led luminiare 2' X 2', 45W , 4-6.5k
Supplying and fixing surface mounting LED down lighter, LED
of 1 to 3 W each assembled on single MCPCB, having color
temp 6500K & having 50000 burning hrs life with minimum
@ L 70, system lumen output should be minimum with
efficacy>80lm/W. LED driver PF 0.95 & THD < 20%. The
colour rendering index of LED light should be more than 70.
Housing made of CRCA powder coated frame with glare free
diffused polycarbonate cover. Submission LM 80-08 Form
LED Source Manufacturer & LM79-08 / IS16106 from NABL
approved lab. Manufacturer mandatory. i/c connection wire,
testing etc. to complete the job. 2 Yrs Guarantee certificate
from manufacturer.
7 W/8 W, 100/150mm
15 W , 180/200mm
30 W , 300mm
Supplying and fixing recessed mounting LED down lighter,
LED of 1 to 3 W each assembled on single MCPCB, having
color temp 6500K & having 50000 burning hrs life with
minimum @ L 70, system lumen output should be minimum
with efficacy>80lm/W. LED driver PF 0.95 & THD < 20%. The
colour rendering index of LED light should be more than 70.
Housing made of CRCA powder coated frame with glare free
diffused polycarbonate cover. Submission LM 80-08 Form
LED Source Manufacturer & LM79-08 / IS16106 from NABL
approved lab. Manufacturer manadatory. i/c connection wire,
testing etc. to complete the job. 2 Yrs Guarantee certificate
from manufacturer.
8 W , 100/150mm
12 W, 180/200mm
15 W, 180/200mm
Supplying and fixing integral post top lantern LED fitting
comprises of copper dust finish cast aluminium spigot and
spun aluminium canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting, open construction driver
and accessories are wired up to terminal block. LED of 1 to 3
W each assembled on single MCPCB, having color temp
6500K & having 50000 burning hrs life with minimum @ L
70, system lumen output should be minimum with
efficacy>80lm/W. LED driver PF 0.95 & surge protection 2KV.
The colour rendering index of LED light should be more than
70. Submission LM 80-08 Form LED Source Manufacturer &
LM79-08 / IS16106 from NABL approved lab. Manufacturer
manadatory. i/c connection wire, testing etc. to complete the
job. 2 Yrs Guarantee certificate from manufacturer.59
40 W LED
Supplying and fixing street light with high power LED of 1
to 3 W each assembled on single MCPCB, system lumens
4753
11126
10251
2348
3822
6955
1657
2348
2763
16654
SOR ELECTRICAL 2014/CHAPTER-31
Page 59 of 114
31.29.1
31.29.2
31.29.3
31.29.4
31.29.5
31.29.6
31.30
31.30.1
31.30.2
31.30.3
31.30.4
31.30.5
31.30.6
31.31
31.31.1
31.31.2
output with efficacy>90 lm/W. luminiare having color temp
6500K & 50000 burning hrs life with minimum @ L 70,
The colour rendering index of LED light should be more
than 70. Luminiare comprises of driver, PF 0.95 & surge
protection 3KV. Housing made of pressure die cast
aluminium with heat resistant flat glass / Lens type, IP65
protection. Submission LM 80-08 Form LED Source
Manufacturer & LM79-08 / IS16106 from NABL approved
lab. Manufacturer manadatory i/c 50mm.dia G.I. Pipe
bracket upto 2 mtr. long in required angle/shape,
connection lead, testing etc to complete the job. 2 Yrs
Guarantee certificate from manufacturer.
24W / 25W
40W / 48W
60W,
90W,
120W,
150W,
Supplying and fixing flood light with high power LED of 1 to
3 W each assembled on single MCPCB, system lumens
output with efficacy>90 lm/W. luminiare having color temp
6500K & 50000 burning hrs life with minimum @ L 70,
The colour rendering index of LED light should be more
than 70. Luminiare comprises of driver, PF 0.95 & surge
protection 3KV. Housing made of pressure die cast
aluminium with heat resistant flat glass, IP65 protection.
Submission LM 80-08 Form LED Source Manufacturer &
LM79-08
/ IS16106 from NABL approved lab.
Manufacturer manadatory i/c connection lead, testing etc
to complete the job. 2 Yrs Guarantee certificate from
manufacturer.
10W
30W
60W,
90W,
120W,
150W,
Supply, Installation testing and commissioning of Red
colour Aviation light LED integral type comprising of
Aluminium powder coated housing with polycarbonate
enclosure IP 65 on existing pipe/ support including
connection, testing etc. as required. 2 Yrs Guarantee
certificate from manufacturer. :180 LED
300 LED
9138
18634
22584
23923
35585
44283
4628
10184
24048
25378
25378
34257
Each
Each
6053
846560
SOR ELECTRICAL 2014/CHAPTER-31
Page 60 of 114
CHAPTER - 32
MISCELLANEOUS
S.No
Description of Item
32.1
Fixing of Fluorescent Tube fitting on wall /ceiling on wooden
round block with anchor fastener /J hook & necessary
material including connection with 3 core flexible wire etc.
complete as required.
32.2
32.2.1
32.2.2
32.3
32.3.1
32.3.2
32.4
32.5
32.6
32.6.1
32.6.2
32.6.3
32.7
Unit
Each
Fixing of Fluorescent Tube fitting with pendant arrangement
of two pieces of approved metallic chain with necessary
material including connection with 3 core flexible wire etc.
complete as required.
For pendent length up to 1.5 Metre
Each
Add additional pendent length in excess of 1.5 Metre
Metre
Fixing of Fluorescent Tube fitting with stiff pendant
arrangement of two pieces of steel conduit and with anchor
fastener /J hook & other necessary material including
connection with 3 core flexible wire etc. complete as required.
For pendent length up to 1.5 Metre
Each
Add additional pendent length in excess of 1.5 Metre
Metre
Fixing of Fluorescent Tube recessed / concealed mounting
Fitting in existing recesses with necessary material including
connection with 3 core flexible wire etc. complete as required. Each
Providing and fixing circular/Hexagonal cast iron or M.S.sheet
box for ceiling fan clamp of internal dia 140mm, 73mm height,
top lid of 1.5mm thick M.S. sheet with its top surface hacked
for proper bonding, top lid shall be screwed into the cast
iron/M.S. sheet box by mean of 3.3mm dia. round headed
screws, one lock at the corners. Clamp shall be made of
12mm dia M.S. bar bent to shape as per standard drawing.
Each
Supplying and fixing fan clamps of 12 mm dia steel bar as per
specification complete :For stone slab roof "J" Type hook
Each
For R.C.C. Slabs / Beams
Each
For existing old R.C.C. Slabs / Beams
Each
Supplying and fixing fan clamps with hook on existing T.W.
beam/ trusses with required size flat iron etc.as per
specification complete :Each
Rate
(Rs)
67
242
128
383
227
107
140
60
38
95
8161
SOR ELECTRICAL 2014/CHAPTER-32
Page 61 of 114
32.8
32.9
32.10
32.11
32.12
32.12.1
32.12.2
32.13
32.13.1
32.13.2
32.14
32.15
32.16
32.16.1
32.16.2
32.16.3
32.16.4
32.17
32.18
32.19
Erection of ceiling in in position with regulator on existing
switch board including wiring testing etc. with necessary
material complete as required.
Fixing of fan Regulator on existing switch board in position
with necessary material connection etc.complete as required.
Erection of exhaust fan on existing hole / wall bracket
fan/cabin fan in position with required PVC cable, rawl bolts
etc. complete including connections and making wall surface
good.
Supplying and fixing down rod of MS pipe for ceiling fan
including threading, painting, making holes etc. as required
complete :Numbering of ceiling fans or fittings with approved paint
including all labour material etc. complete as required :Lettering up to 7 cm height
Lettering above 7 cm but up to 15 cm height
Providing and fixing wooden board of suitable size (maximum
12" X 18" ) for fixing of house service Metre with necessary
materials and connection testing etc. complete as per
specification :
Single phase Meter
Three phase Meter
Shifting of Window Air Conditioning unit 1.0TR / 1.5 TR / 2 TR
capacity excluding facia and cutting, welding work complete
as required.
Shifting, Installation, testing & commissioning of Split Air
Conditioning unit 1.0TR / 1.5 TR / 2 TR capacity including
indoor/ out door unit complete as required
Supply, Installation, testing & commissioning suction/
discharge copper pipe line in split Air Conditioning unit 1.0
/1.5 TR/2 TR /3 TR capacity including brazing, nitride rubber
insulation, etc complete as required.
Copper tube 1/4"
Copper tube 1/2"
Copper tube 3/8"
Copper tube 5/8"
Chemical Servicing of Window /Split Air Conditioning unit
1TR/ 1.5 TR/2 TR/3TR capacity including cleaning of cooling
& condensing units,filters,grills etc & all other parts oiling &
greasing of fan motor, testing of A.C unit etc.
Gas ( F 22 ) charging of Window /Split Air Conditioning unit
including flushing of cooling & condensing units with nitrogen
gas & rectification of leakage, replacement of filter, flair nut
etc. if any.
Gas charging of Refrigerator upto 300 Ltr capacity including
flushing of cooling & condensing units with nitrogen gas &
rectification of leakage, replacement of filter, etc. if any.
Each
95
Each
23
Each
124
metre
114
Each
Each
3
5
Each
Each
101
133
Each
800
Each
2000
P. Mt.
P. Mt.
P. Mt.
P. Mt.
190
250
460
400
Each
800
P. Ton
Each
1000
100062
SOR ELECTRICAL 2014/CHAPTER-32
Page 62 of 114
32.20
32.21
32.22
32.23
32.24
Providing, replacement & connection thermostat switch of
required size & capacity for Refrigerator upto 300 Ltr capacity
including all required material to complete the job.
Each
Providing, replacement & connection starting relay of required
size & capacity for Refrigerator upto 300 Ltr capacity
including all required material to complete the job.
Each
Providing & fixing of wood wool / Khas pads of normal size
desert / room cooler panels set of 3 Nos including fixing
wiremesh on pads.
Each
Servicing & overhauling of cooler fan motor, pump including
replacemnt of distribution & delivery pipes, PVC elbows,
painting etc. as reqd. complete with necessary material &
labour
Each
Rewinding of fans by copper enameled wire of suitable
gauge
including
all
required
material,
insulation,
varnishing,connection leads,oiling .greasing etc complete
with testing including dismantling & refitting of
fan at
site.Scrap old material is not returnable to the department.
32.24.1 Ceiling Fan 1400 mm sweep old model /Exhaust Fan 450 mm
sweep
32.24.2 Ceiling Fan 1400 mm sweep new model / Exhaust Fan 380
mm sweep
32.24.3 Ceiling Fan 1200 mm sweep old model / Cooler Fan 500 mm
( 20" )sweep
32.24.4 Ceiling Fan 1200 mm sweep new model / Exhaust Fan 300
mm sweep
32.24.5 Fresh Air Fan up to 300 mm sweep / Wall Bracket /Cabin Fan
400 mm sweep
32.25 Cleaning, overhauling, servicing of ceiling / Exhaust / Wall
bracket fan by applying grease & oil, including testing with
mounting / Hanging arrangement including replacement of
safety pins, check nuts,lock nut,nut bolts etc. making perfect
alignment & refitting at site as required.
32.26
32.27
32.27.1
32.27.2
32.27.3
32.27.4
450
105
99
Each
546
Each
338
Each
417
Each
298
Each
211
Each
102
Supply and fixing of GI sheet 22 SWG Exhaust fan cowl
including grouting bolt, nut, & finishing etc on existing hole to
complete the job.
Sq.Mt.
Supply and fixing of GI sheet 24 SWG Exhaust fan Louvers
including grouting bolt, nut, & finishing etc on existing hole to
complete the job as mentioned below :Sweep 300mm
Sweep 380mm
Sweep 450mm
Sweep 600mm
450
Each
Each
Each
Each
950
750
1000
1500
200063
SOR ELECTRICAL 2014/CHAPTER-32
Page 63 of 114
CHAPTER -33
LABOUR RATES FOR WIRING
S.No
Description of Item
33.1
Labour rate for point wiring a Light / Fan / Twin control light /
Socket out let on separate board / Call bell Point in (open)
surface rigid steel conduit system.
33.2
33.3
33.4
33.5
33.6
33.7
33.7.1
33.7.2
33.7.3
33.8
33.9
33.10
33.10.1
33.10.2
33.10.3
Unit
Each
Labour rate for point wiring a Light / Fan / Twin control light /
Socket out let on separate board / Call bell Point in
recessed/concealed rigid steel conduit system.
Each
Labour rate for point wiring a Light / Fan / Twin control light /
Socket out let on separate board / Call bell Point in (open)
surface rigid PVC conduit / Casing- n- capping system.
Each
Labour rate for point wiring a Light / Fan / Twin control light /
Socket out let on separate board / Call bell Point in
recessed/concealed rigid PVC conduit system.
Each
Labour rate for point wiring a Power Point in surface rigid
steel / PVC conduit / Casing-N-Capping system including
labour for fixing earth continuity conductor .
Each
Labour rate for point wiring a Power Point in recessed /
concealed rigid steel / PVC conduit system including labour
for fixing earth continuity conductor .
Each
Labour rate for fixing rigid steel / PVC conduit in surface
/concealed conduit wiring system, as per specification .
20 mm Conduit
Metre
25 mm & 32 mm Conduit
Metre
40 mm & 50 mm Conduit
Metre
Labour rate for rewiring a Light / Fan / Twin control light /
Socket out let on separate board / Call bell Point in rigid
steel / rigid PVC non metallic conduit / PVC Casing-NCaping in (open) surface conduit wiring system.
each
Labour rate for rewiring a Light / Fan / Twin control light /
Socket out let on separate board / Call bell Point in rigid
steel / rigid PVC non metallic conduit in recessed/concealed
conduit wiring system.
each
Labour rate for fixing rigid PVC conduit as per specification
in recessed/concealed conduit wiring system.
20 mm Conduit
Each
25 mm & 32 mm Conduit
Each
40 mm & 50 mm Conduit
Each
Rate
(Rs)
137
179
98
143
208
251
13
15
25
164
174
19
23
3664
SOR ELECTRICAL 2014/CHAPTER-33
Page 64 of 114
33.11
33.11.1
33.11.1.1
33.11.1.2
33.11.1.3
33.11.2
33.11.2.1
33.11.2.2
33.11.2.3
NOTE
Labour rate for drawing cables in existing rigid steel / PVC
conduit
/
Casing-N-Capping
(surface
or
recessed/concealed)
"A" 2 Wires -2.5 sq mm / 4 sq mm / 6 sq mm
metre
10 sq mm / 16 sq mm / 25 sq mm
metre
35 sq mm
metre
"B" 3 Wires & 4 Wires
2.5 sq mm / 4 sq mm / 6 sq mm
metre
10 sq mm / 16 sq mm / 25 sq mm
metre
35 sq mm
metre
29
32
33
31
34
34
1. The socket outlet point on the same board shall be treated as 1/2 point in the
respective system of wiring
2. Labour rate for point wiring are inclusive of labour for fitting all accessories and
fitting such as conduit, switch, Ceiling rose sockets, brass lamp holders etc. as
required
3. Labour rate for each circuit shall be same as one point in respective system of
wiring .65
SOR ELECTRICAL 2014/CHAPTER-33
Page 65 of 114
CHAPTER- 34
PAINTING
Description of Item
S.No
34.1
34.2
34.3
34.4
34.4.1
34.4.2
34.4.3
Painting of ceilling fan including making surface clean and
spray painting of fan Motor, blades, etc. with two coat of
required shade complete with material and labour including
dismantling and erection, preparation of surface
Unit
Rate
(Rs)
Each
218
Each
540
Painting of desert cooler including making surface even,
prima paint coat from inside & outside and spray painting of
body, fan Motor, blades, etc. with two coat of required
shade complete with material and labour.
Painting of water cooler including scraping of old paint
making surface even, prima paint coat and spray painting of
body, etc. with two coat of required shade complete with
material and labour.
Each
PAINTING OF POLES :Removing of old paint from steel and other metallic surface per sq
and making surface even.
Metre
Primer coat over new steel and other metallic surface with
red oxide/ zinc chromide paint complete with supply of per sq
material labour etc. including preparation of surface.
Metre
Final coat with aluminium paint, brushing complete including per sq
material and labour.
Metre66
649
18
47
59
SOR ELECTRICAL 2014/CHAPTER-34
Page 66 of 114
CHAPTER - 35
DISMANTLING OF CIVIL & ELECTRICAL WORKS
Description of Item
S.No
35.1
35.2
35.3
35.4
35.5
35.6
35.7
35.8
35.9
35.10
35.11
35.12
35.13
Dismantling of existing light / Fan / Bell / Socket out let point
on separate board / Wiring and circuit with insulated wire in
cassing / conduit / Batten complete with fitting and
accessories
Making the site clear of the dismentalled installation by
refilling the hole with cement mortor & finished with paint
gitties and replacing to match the colour of wall / ceilling.
Dismetalling of existing socket outlet point on same board in
any system of wiring
Dismentalling the existing armoured / unarmoured cable or
2/3/4 wires of submain, main , in any system of wiring
including recoiling.
Dismentalling of existing undreground cable safely with its
accessories and refilling the trench to ground level including
recoiling of dismentalled cable.
Dismentalling of D.F. Board, D.P. Switch, T.P. &T.P.N. Switch
or D.B. of any size complete with board or angle / flat iron
frame and making site clear including the refilling hole &
repainting to match colour of wall.
Dismentalling of D.F. Board , D.P.Switch , T.P. & T.P.N.
Switch or D.B. of any size only
Dismentalling the existing ceiling / exhaust / cabine fan with
complete accessories and making the site clear.
Dismentalling of existing steel pole, R.S.Joist, girder with
bracket clamps insulator or stay from the cement concrete
foundation and making the site clear by refilling the pit to
ground level i/c transportation to required destination within
township.
Dismentalling of existing overhead ACSR, AAAC, GI ,
conductor and making the site clear i/c transportation to
required destination within township.
Dismentalling of existing water tight flourescent tube fitting /
M.V. Lamp fitting with making the site clear.
Dismentalling of existing water tight fitting S.V/M.H/L.E.D
Lamp fitting with extension bracket, clamp from pole or wall
with making the site clear.
Dismentalling of existing geyser or storage type water heater
and making the site good by colour wash etc.as required.
Unit
Rate
(Rs)
per point
17
per point
30
per point
11
per
meter
11
per
meter
34
Each
38
Each
15
Each
36
Each
1066
per
meter
4
Each
30
Each
3967
Each
61
SOR ELECTRICAL 2014/CHAPTER-35
Page 67 of 114
35.14
Providing recess in brick wall suitable for erection of exhaust
fan up to 600mm sweep complete with grouting of nut bolts,
plastering and colour wash to match the colour of wall.
35.14.1 For wall thickness up to 9"
35.14.2 For wall thickness up to 15"
35.14.3 For the stone wall thickness up to 15"
498
778
907
Each
Each
Each
CHAPTER - 36
CIVIL WORKS
S.No
Description of Item
Note:
Items regarding civil works shall be taken and
executed on the basis of rates of current respective
civil S.O.R.
Rate
(Rs)
Unit
68
SOR ELECTRICAL 2014/CHAPTER-35-36
Page 68 of 114
CHAPTER - 37
EARTHING , LOOP EARTHING,LIGHTNING CONDUCTOR
Description of Item
S.No
37.1
37.2
37.2.1
37.2.2
37.3
37.4
37.5.1
37.5.2
37.6
37.7
37.8
Earthing with G.I. Earth pipe 4.5 Metre long and 40 mm dia
with masonary enclosure in cement mortor, cover plate
having locking arrangement on the top etc.(but without
charcoal or coke and salt) complete as required.
Add Extra for using salt and charcoal / coke for pipe earth
electrode as required including excavation & refilling.
Excavation 2.5 cum by manual labour
Excavation by making hole with Auger
Earthing with G.I. Earth plate 600mm X 600mm X 6mm
thick including accessories and providing masonary
encloser in cement mortor, cover plate having locking
arrangement on the top and G.I. watering pipe 20mm dia
2.7 Metre long etc. (but without charcoal or coke and salt )
complete as required.
Earthing with Copper Earth plate 600mm X 600mm X 3mm
thick including accessories and providing masonary
encloser in cement mortor, cover plate having locking
arrangement on the top and G.I. watering pipe 20mm dia
2.7 Metre long etc. (but without charcoal or coke and salt)
complete as required.
Add Extra for using salt and charcoal / coke for G.I. Plate or
Copper plate earth electrode as required including
excavation & refilling.
Add Extra for using salt and charcoal / coke for G.I. Plate or
Copper plate earth electrode as required including
excavation in hard rock and refilling the pit with black soil.
Unit
Each
3017
Each
Each
1572
1068
Each
2951
Each
8013
Each
1841
Each
3353
Supplying and laying 8 SWG (4 mm) copper wire at 0.5
Metre below ground level as conductor earth electrode
including soldering etc. as required.
metre
Supplying and laying 6SWG (5.6mm) G.I. wire at 0.5 Metre
below ground level as conductor earth electrode including
soldering etc. as required.
metre
Supplying and laying 25mm X 5mm G.I. strip at 0.5 Metre
below ground level as strip earth electrode including
soldering etc. as required.
Rate
(Rs)
metre
85
23
9569
SOR ELECTRICAL 2014/CHAPTER-37
Page 69 of 114
37.9
37.10
37.11
37.12
37.13
37.14
37.15
37.16
37.17
37.18
37.19
37.20
37.21
37.22
37.23
Supplying and laying 25mm X 6mm G.I. strip at 0.5 Metre
below ground level as strip earth electrode including
soldering etc. as required.
metre
Providing & fixing 25mm X 5mm copper strip in 40mm dia
G.I.pipe (B class) from earth electrode as required.
metre
Providing & fixing 25mm X 5mm G.I.strip in 40mm dia G.I.
Pipe (B class) from earth electrode as required.
metre
Providing and laying earth connections from earth electrode
with 4.00 mm dia G.I. wire in 15mm dia G.I. Pipe (B class)
from earth electrode as required.
metre
Providing and laying earth connections from earth electrode
with 4.00 mm dia copper wire in 15mm dia G.I. Pipe (B
class) from earth electrode as required.
metre
Providing & fixing 25mm X 5mm copper strip on surface or
recessed for connection etc. as required.
Providing and fixing 25mm X 4mm G.I. strip on surface or in
recessed/concealed for connection etc. as required.
Providing and fixing 6 SWG (5.6mm) G.I. wire on surface or
in recessed/concealed for loop earthing as required.
Providing and fixing 4.00mm copper wire on surface or in
recessed/concealed for loop earthing as required.
Supplying and laying 50mm X 6mm G.I. strip at 0.5 metre
below ground level / surface as strip earth electrode
including jointing etc. as required.
113
1043
423
149
204
metre
808
metre
123
metre
19
metre
86
metre
LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial made of
25mm dia 300mm long copper tube having single prong at
top with 85 mm dia 3 mm thick copper base plate including
holes complete as required.
Each
Providing and fixing of lightning conductor finial made of
25mm dia 300mm long G.I. tube having single prong at top
with 85 mm dia 6 mm thick G.I. base plate including holes
complete as required.
Each
Fixing of lightning conductor finial made of 25mm dia
300mm long copper tube / G.I. tube having single prong at
top with base plate etc complete as required.
Each
95
Rivetting / Sweating and soldering of copper / G.I. Tape
(with another copper / G.I. Tape, base of finial or any other
metallic object ) as required.
Each
Providing and fixing copper tape 20mm X 3mm thick on
parapet and surface of wall of lightening conductor as
required ( for Horizontal runs )
metre
2482
1222
281
114
36870
SOR ELECTRICAL 2014/CHAPTER-37
Page 70 of 114
37.24
37.25
37.26
37.27
37.28
37.29
37.30
37.31
37.32
37.33
37.34
37.35
37.36
Providing and fixing copper tape 20mm X 3mm thick on
parapet and surface of wall of lightening conductor as
required ( for Vertical runs )
metre
Providing and fixing G.I. tape 20mm X 3mm thick on
parapet and surface of wall of lightening conductor as
required ( for Horizontal runs )
metre
Providing and fixing G.I. tape 20mm X 3mm thick on
parapet and surface of wall of lightening conductor as
required ( for Vertical runs )
metre
Fixing of copper / G.I. Tape 20mm X 3mm thick on parapet
and surface of wall for lightening conductor as required ( for
Horizontal runs )
metre
Fixing of copper / G.I. Tape 20mm X 3mm thick on parapet
and surface of wall for lightening conductor as required ( for
Vertical runs )
metre
Providing and fixing " Testing Joint" made by 20mm X 3mm
thick copper strip 125mm long with 4 Nos of tinned Brass
bolts, Nut, check nuts and spring washers etc. complete as
required .
Each
Providing and fixing " Testing Joint" made by 20mm X 3mm
thick G.I. strip 125mm long with 4 Nos of G.I. bolts, Nut,
check nuts and spring washers etc. complete as required .
Each
Providing and laying copper tape 32mm X 6mm thick for
earth electrode directly in ground as required
metre
Providing and laying G.I. tape 38mm X 6mm thick for earth
electrode directly in ground as required .
metre
Laying of copper / G.I. tape 32mm X 6mm thick for earth
electrode directly in ground as required.
metre
EARTHING FOR DOMESTIC ELECTRIC INSTALLATION
Providing and fixing earthing arrangement with 16mm dia
2.5 metre long galvanized iron or steel rod electrode
including packing of charcoal powder and salt as per
specification watering pipe 19mm dia G.I. Connection, cover
plate having locking arrangement on the top etc. complete
with refilling the pit as required, including excavation of
earth pit in soil/ soft rock.
Each
Providing and fixing earthing arrangement with 38.1mm dia
2.5 metre long galvanized iron pipe electrode including
packing of charcoal powder and salt as per specification
watering pipe 19mm dia G.I. Connection, cover plate having
locking arrangement on the top etc. complete with refilling
the pit as required, including excavation of earth pit in soil /
soft rock
Each
Supplying and laying G.I. earth lead duly installed on wall or
in G.I. Pipe including connections etc complete as required.
411
71
114
32
75
287
124
1283
161
58
2287
272871
SOR ELECTRICAL 2014/CHAPTER-37
Page 71 of 114
37.36.1
37.36.2
37.36.3
37.37
37.37.1
37.37.1.1
37.37.1.2
37.37.1.3
37.37.1.4
37.37.2
37.37.2.1
37.37.2.2
37.38
37.39
37.39.1
37.39.2
37.39.3
37.39.4
37.39.5
37.40
37.40.1
13 sq mm ( 4 mm dia )
Metre
25 sq mm ( 5.6 mm dia )
Metre
40 sq mm ( 7.1 mm dia )
Metre
Providing and laying earth continuity conductor including
fixing with copper clamps and other necessary materials as
per specification along the run of conduit.
Aluminium Earth Continuity Conductor :6 Sq mm.
10 Sq mm.
16 Sq mm
25 Sq mm.
G.I. Or Steel Earth Continuity Conductor :6 Sq mm.
10 Sq mm.
Providing and laying earth Continuity Conductor of 4 Sq mm
Aluminium along the run of final sub circuit in PVC conduit
in an approved manner.
17
26
37
Metre
Metre
Metre
Metre
17
28
54
95
Metre
Metre
12
15
Metre
13
4 Sq mm
Metre
6 Sq mm.
Metre
10 Sq mm.
Metre
16 Sq mm
Metre
25 Sq mm.
Metre
supplying and erecting earth pit of minimum bore dia.
150mm size , approved make Safe Earthing Electrode
consisting Pipe-in-Pipe technology as per IS 3043-1987
made of corrosion free G.I. Pipes with constant ohmic value
surrounded by highly conductive compound with high
charge dissipation suitable for effective and maintenance
free earthing as mentioned below :
With 2 mtr. G.I. Pipes having outer pipe dia of 50mm having
80-200 micron galvanizing, Inner pipe dia. of 25mm having
200-250 Micron galvanizing, connection terminal dia.of
12mm in nominal soil with 25 kg (one Bag) Back filling
Compound.
Each
41
58
88
136
207
Supplying and drawing PVC insulated copper cable ( Earth
Continuity Conductor ) of Green colour FR with copper
multi strand conductor ISI marked in existing conduit along
with other wires as required as per specification :
686372
SOR ELECTRICAL 2014/CHAPTER-37
Page 72 of 114
37.40.2
37.40.3
37.40.4
37.41
37.42
37.42.1
37.42.2
37.43
With 3 mtr. G.I. Pipes having outer pipe dia of 50mm having
80-200 micron galvanizing, Inner pipe dia. of 25mm having
200-250 Micron galvanizing, connection terminal dia.of
12mm in nominal soil with 50 kg (Two Bag) Back filling
Compound.
Each
With 2 mtr. Pipe of 80mm outer dia. , 40mm inner dia and
14mm terminal dia. In soft rock/marshy soil with 25 kgs.
(one Bag) Back filling Compound.
Each
With 3 mtr. Pipe of 80mm outer dia. , 40mm inner dia and
14mm terminal dia. In soft rock/marshy soil with 50 kgs.
(Two Bag) Back filling Compound.
Each
Providing Back Filling Compound suitable for safe earthing
device.
Supplying, installing, testing and commissioning
of
Lightning protection system with Early Streamer Emission
(ESE), OPR (Optimized Pulse Rod) technology, of
protection level -1, having a coverage range and mounted
at a height as mentioned below including stainless steel
mast & mounting structure kit as per specifications.
OPR 30, radius 67Mt., Height 3 Mt
OPR 60, radius 97Mt., Height 3 Mt
Supplying, installing, testing and commissioning of Lightning
Discharging Counter to verify the lighting discharge
occurrence.
Kg
10006
16673
19195
30
Each
Each
180000
216000
Each
4500073
SOR ELECTRICAL 2014/CHAPTER-37
Page 73 of 114
CHAPTER - 38
TELEPHONE, LAN, TV CABLE
Description of Item
S.No
38.1
38.2
38.2.1
38.2.2
38.2.3
38.2.4
38.3
38.3.1
38.3.2
38.3.3
38.4
38.4.1
38.4.2
38.4.3
38.4.4
38.5
38.6
38.7
Unit
suppling and drawing Co-axial T.V. Cable RG-6 Grade , 0.7
mm Solid Copper conductor PF Insulated , Shielded with fine
tined copper braid and protected with PVC Sheathed in the
existing surface / concealed ,steel / PVC. Conduit as
required.
Metre
Supplying and drawing following pair of 0.5 mm size solid
annealed copper conductor PVC Insulated telephone cable
as per DOT Specifications in existing surface / concealed
steel / PVC Conduit / Casing-N-Capping as required.
Rate
(Rs)
28
(i) 1 Pair
(ii) 2 Pair
(iii) 4 Pair
(iv) 10 Pair
Supply installation, testing commissioning of 0.5 mm size
Solid annealed copper, Jelly Filled Telephone Cables,
Polythene Insulated, Petroleum Jelly Filled with Poly-al
laminate moisture barrier, Polythene Sheathed, Unarmoured
Polythene Jacketed Telephone Cables as per DOT
Specifications of following sizes
10 Pair
20 Pair
50 Pair
Supply, Installation testing and commissioning of telephone
Tag block Krone connector with enclosure and lock complete
as mentioned below :-
Metre
Metre
Metre
Metre
7
11
22
53
Metre
Metre
Metre
70
126
297
10 Pair
20 Pair
30 Pair
50 Pair
Supply, fixing and testing RJ - 11 Telephone Jack Single with
shutter F.T
Supply, fixing and testing of RJ 11 telephone jack modular (1
Module)
Supply, fixing and testing of T.V. Outlet F.T
each
each
each
each
263
273
297
341
each
57
each
12974
34
SOR ELECTRICAL 2014/CHAPTER-38
Page 74 of 114
38.8
38.9
38.10
38.11
38.12
38.12.1
38.12.2
38.12.3
38.12.4
38.13
38.14
38.15
38.15.1
38.15.2
38.15.3
Supply, fixing and testing of T.V. Outlet Modular (1Module)
Supply, Installation testing and commissioning RJ - 45
Computer Jack cat 6 with shutter Modular (1Module)
each
Supply, Installation testing and commissioning RJ - 45
Computer Jack cat 6 with shutter Modular (2Module)
each
Suppling and drawing 4 pair shielded, 0.5 mm PVC.Insulated
copper conductor un-armoured Cat-6 computer cable FR in
existing surface / concealed ,steel / PVC. Conduit/Casing-NCapping as required.
per Mtr
Supply, Installation testing and commissioning of patch cord
as mentioned below :CAT 6 RJ45 Patch Cord F/UTP 1 Mtr.
each
CAT 6 RJ45 Patch Cord F/UTP 2 Mtr.
each
CAT 6 RJ45 Patch Cord F/UTP 3 Mtr.
each
CAT 6 RJ45 Patch Cord F/UTP 5 Mtr.
each
Supply, Installation testing and commissioning of 19" Modular
Patch - 1 U Patch Panel 24, RJ 45 Cat-6 connector
each
Supply, Installation testing and commissioning of 19" Modular
telephone Patch Panel 24 - 1 U with RJ 11 connector
each
Supply, Installation testing and commissioning of wall
mounting
rack, for computer switches complete as
mentioned below :6U cabinet 371.30X600X500, wall mounting with power
supply and Fan etc.
each
9U cabinet 504.65X600X500, wall mounting with power
supply and Fan etc.
each
12U cabinet 638X600X500, wall mounting with power supply
and Fan etc.
each
129
491
501
46
407
450
585
698
10926
20018
13187
15809
1748775
SOR ELECTRICAL 2014/CHAPTER-38
Page 75 of 114
CHAPTER - 39
SINGLE / THREE PHASE SUBMERSIBLE / OPENWELL / CENTRIFUGAL MOTOR
PUMP SET.
Rate
S.No
Description of Item
Unit
(Rs)
39.1
39.1.1.1
39.1.1.2
39.1.1.3
39.1.1.4
39.1.1.5
39.1.2.1
39.1.2.2
39.1.2.3
39.1.2.4
39.1.2.5
39.1.3.1
39.1.3.2
39.1.3.3
39.1.3.4
39.1.3.5
Supplying & Installation of required capacity of single
phase, 50 Hz,220V, deep well submersible pump Stainless
Steel body, as per IS of approved Make, suitable for 4"/6 "
tube well with Control Panel Starter suitable for Submersible
pump with dry run protection, connections, including
clamps, bore cap etc. as required as per specifications but
excluding Pipe, SS/Nylon wire rope and connection cable.
0.5 H.P. with 6 to 7 stages, Head Mt 46-13, Discharge LPM
10-55
1 H.P. with upto 5 stages, Head Mt 35-15, Discharge
LPM 40-125
1 H.P. with 7 to 8 stages, Head Mt 61-18, Discharge
LPM 25-90
1 H.P. with 10 to 11 stages, Head Mt 74-21, Discharge
LPM 15-55
1 H.P. with 12 to 14 stages, Head Mt 91-28, Discharge
LPM 10-45
1.5 H.P. with up to 6 stages, Head Mt 42-17, Discharge
LPM 65-150
1.5 H.P. with 7 to 8 stages,
Head Mt 56-21, Discharge
LPM 40-125
1.5 H.P. with 10 to 11 stages, Head Mt 84-26, Discharge
LPM 25-90
1.5 H.P. with 16 to 17 stages, Head Mt 114-33, Discharge
LPM 15-55
1.5 H.P. with 18 to 20 stages, Head Mt 130-41, Discharge
LPM 10-45
2 H.P. with 7 to 8 stages, Head Mt 56-16, Discharge LPM
65-205
2 H.P. with 10 to 11 stages, Head Mt 77-30, Discharge
LPM 40-125
2 H.P. with 14 to 15 stages, Head Mt 114-36, Discharge
LPM 25-90
2 H.P. with 20 to 22 stages, Head Mt 147-42, Discharge
LPM 15-55
2 H.P. with 25 stages, Head Mt 163-58, Discharge LPM 1045
each
22837
each
24129
each
24539
each
25421
each
26209
each
28661
each
29449
each
28945
each
29039
each
31182
each
32783
each
33067
each
31743
each
31271
each
3637676
SOR ELECTRICAL 2014/CHAPTER-39
Page 76 of 114
39.1.4.1
39.1.4.2
39.1.4.3
39.2
39.2.1.1
39.2.2.1
39.2.2.2
39.2.2.3
39.2.3.1
39.2.3.2
39.2.3.3
39.2.4.1
39.2.4.2
39.3
39.3.1.1
39.3.1.2
39.3.1.3
39.3.1.4
39.4
3 H.P. with 10 to 12 stages, Head Mt 84-23, Discharge
LPM 65-205
3 H.P. with 15 to 17 stages, Head Mt 119-45, Discharge
LPM 40-125
3 H.P. with 20 to 22 stages, Head Mt 167-51, Discharge
LPM 25-90
Supplying & Installation of required capacity of Three
phase, 50 Hz,415V, deep well submersible pump Steel
body, as per IS of approved Make, suitable for 6 " tube well
with Control Panel Starter suitable for Submersible pump
with dry run protection, single phase preventer,
connections, including clamps, bore cap etc. as required as
per specifications but excluding Pipe and connection cable.
3 H.P. with up to 6 stages, Head Mt 55-7, Discharge LPM
60-510
5 H.P. with up to 5 stages, Head Mt 55-13, Discharge LPM
120-510
5 H.P. with 8 to 9 stages, Head Mt 83-32, Discharge LPM
60-270
5 H.P. with 10 to 11 stages, Head Mt 101-40, Discharge
LPM 60-270
7.5 H.P. with 8 to 10 stages, Head Mt 117-31, Discharge
LPM 60-420
7.5 H.P. with 13 to 14 stages, Head Mt 129-52, Discharge
LPM 60-270
7.5 H.P. with 15 stages, Head Mt 138-60, Discharge LPM
60-270
10 H.P. with 16 stages, Head Mt 147-64, Discharge LPM
60-270
10 H.P. with 20 stages, Head Mt 184-80, Discharge LPM
60-270
Supplying and laying of submersible flat cable ISI marked 3
core copper wire of suitable size with proper clamping of
approved make.
2.5 Sq.mm multi strand
4.0 Sq.mm multi strand
6.0 Sq.mm multi strand
10.0 Sq.mm multi strand
Supplying and laying of approved Make HDPE pipe as per
IS : 4984 and IS : 14333 with latest amendment for
installation of submersible pump with necessary connection,
socket/couplings, Tees,etc. as required (PE-63 & working
Pressure 10 kgf/sq cm)77
each
35178
each
36238
each
34800
each
39529
each
44349
each
47375
each
50022
each
55383
each
62999
each
65426
each
68956
each
76015
per mtr
per mtr
per mtr
per mtr
132
185
274
442
SOR ELECTRICAL 2014/CHAPTER-39
Page 77 of 114
39.4.1.1
39.4.1.2
39.4.1.3
39.4.1.4
39.5
39.6
39.7
39.7.1.1
39.7.1.2
39.8
39.8.1.1
39.8.1.2
39.8.1.3
39.9
39.9.1.1
39.9.1.2
39.9.1.3
39.10
25 mm Outer Dia.
32 mm Outer Dia.
40 mm Outer Dia.
50 mm Outer Dia.
Supplying and laying of approved Make Nylon rope 12 mm
thick complete with binding for support of pump and motor.
Supplying and laying of approved Make Stainless Steel wire
rope 6 mm thick complete with binding for support of pump
and motor.
Supplying & Installation of approved Make required capacity
single phase, 50 Hz,220V, Centrifugal Mono-block pump
self priming, with Starter , connections, base channel
foundation etc. as required as per specifications but
excluding Pipe and connection cable.
1 H.P. Head Mt 6-30, Discharge LPH 2400-900
1 H.P. Head Mt 21-45, Discharge LPH 1800-400 (Domestic
Model)
Supplying & Installation of approved Make required capacity
single phase, 50 Hz,240V, Centrifugal Mono-block pump,
with Starter , connections, base channel foundation etc. as
required as per specifications but excluding Pipe and
connection cable.
1 H.P. Head Mt 3-24, Discharge LPH 27000-1500
1.5 H.P. Head Mt 3-21, Discharge LPH 39600-6000
2.0 H.P. Head Mt 3-18, Discharge LPH 48600-3000
Supplying & Installation of approved Make required capacity
3 phase, 50 Hz, 415V, Centrifugal Mono-block pump, with
Starter i/c single phase preventor, connections, base
channel foundation etc. as required as per specifications
but excluding Pipe and connection cable.
per mtr
per mtr
per mtr
per mtr
83
115
171
248
per mtr
75
per mtr
171
3.0 H.P. Head Mt 6-15, Discharge LPM 740-465
5.0 H.P. Head Mt 6-33, Discharge LPM 1380-450
7.5.0 H.P. Head Mt 24-37, Discharge LPM 780-320
Supplying & Installation of approved Make required capacity
3 phase, 50 Hz, 415V, Open Well Submersible pump, with
Control Panel Starter with Dry Run Protection, single phase
preventer, connections,
etc. as required as per
specifications but excluding Pipe and connection cable.
39.10.1.1 3.0 H.P. Head Mt 15-24, Discharge LPM 615-195
39.10.1.2 5.0 H.P. Head Mt 15-24, Discharge LPM 930-420
each
13114
each
8144
each
each
each
12572
15102
16764
each
each
each
21195
25967
33241
each
each
24724
2657478
SOR ELECTRICAL 2014/CHAPTER-39
Page 78 of 114
CHAPTER - 40
WIRING OF OLD STANDARD F/G/H/I QTRS & NEW WIRING OF NEW
STANDARD F/G/H/I QTRS
S.No.
Description of Item
40
Wiring of Old standard F/G/H/I qtrs and New wiring of
new standard F/G/H/I qtrs.
40.1
40.1.1
Re-wiring of Old standard F/G/H/I qtrs
Dismentalling of wiring in "I" type quarter and rewiring in
same in surface Rigid PVC Conduit system.
Dismentalling of wiring in "I" type quarter and rewiring in
same in surface Rigid PVC Casing-N- Capping system.
Dismentalling of wiring in "H" type quarter and rewiring in
same in surface Rigid PVC Conduit system.
Dismentalling of wiring in "H" type quarter and rewiring in
same in surface Rigid PVC Casing-N- Capping system.
Dismentalling of wiring in "G" type quarter and rewiring in
same in surface Rigid PVC Conduit system.
Dismentalling of wiring in "G" type quarter and rewiring in
same in surface Rigid PVC Casing-N- Capping system.
Dismentalling of wiring in "F" type quarter and rewiring in
same in surface Rigid PVC Conduit system.
Dismentalling of wiring in "F" type quarter and rewiring in
same in surface Rigid PVC Casing-N- Capping system.
Wiring of newly constructed F/G/H/I qtrs.
Wiring in newly constructed "I" type quarter in surface Rigid
PVC Conduit system.
Wiring in newly constructed "I" type quarter in surface Rigid
PVC Casing-N- Capping system.
Wiring in newly constructed "H" type quarter in surface
Rigid PVC Conduit system.
Wiring in newly constructed "H" type quarter in surface
Rigid PVC Casing-N- Capping system.
Wiring in newly constructed "G" type quarter in surface
Rigid PVC Conduit system.
Wiring in newly constructed "G" type quarter in surface
Rigid PVC Casing-N- Capping system.
Wiring in newly constructed "F" type quarter in surface
Rigid PVC Conduit system.
Wiring in newly constructed "F" type quarter in surface
Rigid PVC Casing-N- Capping system.
40.1.2
40.1.3
40.1.4
40.1.5
40.1.6
40.1.7
40.1.8
40.2
40.2.1
40.2.2
40.2.3
40.2.4
40.2.5
40.2.6
40.2.7
40.2.8
Unit
Rate
(Rs)
Using Flush
Type Normal
Accessories
Each
26802
Each
26833
Each
30268
Each
30326
Each
35971
Each
36426
Each
61944
Each
62516
Each
33749
Each
33780
Each
38887
Each
38757
Each
47240
Each
47779
Each
76908
Each
77480
Note:- Above comprehensive(composite) items include points as detailed in
Annexure-179
SOR ELECTRICAL 2014/CHAPTER-40
Page 79 of 114
CHAPTER -41 (External)
UNDER GROUND CABLES
S.No.
1
41.1
41.1.1
41.1.1.1
41.1.1.2
41.1.1.3
41.1.1.4
41.1.1.5
41.1.1.6
41.1.1.7
41.1.1.8
41.1.1.9
41.1.2
41.1.2.1
41.1.2.2
41.1.2.3
41.1.2.4
41.1.2.5
41.1.2.6
41.1.2.7
41.1.2.8
41.1.2.9
41.1.3
41.1.3.1
41.1.3.2
41.1.3.3
41.1.3.4
41.1.3.5
41.1.4
41.1.4.1
Description of Item
2
Unit
3
Rate
4
Supply of XLPE Insulated power cable (confirming IS-7098
Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI
MARKED with Alu. Stranded /solid conductor
UNARMOURED 1 Core
16 Sq.mm.
25 Sq.mm.
35 Sq.mm.
50 Sq.mm.
70 Sq.mm.
95 Sq.mm.
120 S.qmm.
150 Sq.mm.
300 Sq.mm.
ARMOURED 1 Core
16 Sq.mm.
25 Sq.mm.
35 Sq.mm.
50 Sq.mm.
70 Sq.mm.
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
300 Sq.mm.
UNARMOURED 2 Core
2.5 Sq.mm.
4 Sq.mm.
6 Sq.mm.
10 Sq.mm.
16 Sq.mm.
ARMOURED 2 Core
2.5 Sq.mm.
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
48
61
76
98
130
168
210
256
316
Metre
83
101
122
148
188
212
255
303
553
Metre
Metre
Metre
Metre
Metre
50
77
86
110
134
Metre
8680
SOR ELECTRICAL 2014/CHAPTER-41
Page 80 of 114
41.1.4.2
41.1.4.3
41.1.4.4
41.1.4.5
41.1.5
41.1.5.1
41.1.5.2
41.1.5.3
41.1.5.4
41.1.5.5
41.1.5.6
41.1.5.7
41.1.5.8
41.1.6
41.1.6.1
41.1.6.2
41.1.6.3
41.1.6.4
41.1.6.5
41.1.6.6
41.1.6.7
41.1.6.8
41.1.7
41.1.7.1
41.1.7.2
41.1.7.3
41.1.7.4
41.1.7.5
41.1.7.6
41.1.7.7
41.1.7.8
41.1.7.9
41.1.7.10
41.1.7.11
41.1.8
41.1.8.1
41.1.8.2
41.1.8.3
4 Sq.mm.
6 Sq.mm.
10 Sq.mm.
16 Sq.mm.
UNARMOURED 3 Core
6 Sq.mm.
10 Sq.mm.
16 Sq.mm.
25 Sq.mm
35 Sq.mm
50 Sq.mm
70 Sq.mm
95 Sq.mm.
ARMOURED 3 Core
6 Sq.mm.
10 Sq.mm.
16 Sq.mm.
25 Sq.mm
35 Sq.mm
50 Sq.mm
70 Sq.mm
95 Sq.mm.
3½ CORE UNARMOURED
25 Sq.mm
35 Sq.mm
50 Sq.mm
70 Sq.mm
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
185 Sq.mm.
240 Sq.mm.
300 Sq.mm.
400 Sq.mm.
3½ CORE ARMOURED
25 Sq.mm
35 Sq.mm
50 Sq.mm
Metre
Metre
Metre
Metre
93
109
133
159
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
78
101
130
180
231
299
414
526
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
127
151
168
219
277
348
468
584
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
210
262
345
477
608
765
921
1158
1478
1818
2345
Metre
Metre
Metre
252
311
40181
SOR ELECTRICAL 2014/CHAPTER-41
Page 81 of 114
41.1.8.4
41.1.8.5
41.1.8.6
41.1.8.7
70 Sq.mm
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
41.1.8.8
185 Sq.mm.
41.1.8.9
240 Sq.mm.
41.1.8.10 300 Sq.mm.
41.1.8.11 400 Sq.mm.
41.1.9
4 CORE UNARMOURED
41.1.9.1
6 Sq.mm.
41.1.9.2
10 Sq.mm.
41.1.9.3
16 Sq.mm.
41.1.9.4
25 Sq.mm
41.1.9.5
35 Sq.mm
41.1.9.6
50 Sq.mm
41.1.9.7
70 Sq.mm
41.1.9.8
95 Sq.mm.
41.1.9.9
120 Sq.mm.
41.1.9.10 150 Sq.mm.
41.1.10
4 CORE ARMOURED
41.1.10.1 6 Sq.mm.
41.1.10.2 10 Sq.mm.
41.1.10.3 16 Sq.mm.
41.1.10.4 25 Sq.mm
41.1.10.5 35 Sq.mm
41.1.10.6 50 Sq.mm
41.1.10.7 70 Sq.mm
41.1.10.8 95 Sq.mm.
41.1.10.9 120 Sq.mm.
41.1.10.10 150 Sq.mm.
41.2
41.2.1
41.2.1.1
41.2.1.2
Supply of approved High-Tension XLPE cable (conforming
IS-7098/II/85 ) as per ISI standard single core Armoured
with Alu. Solid/stranded conductor ISI MARKED as
required
SINGLE CORE XLPE CABLE 11 KV GRADE
50 Sq.mm
70 Sq.mm
41.2.1.3
95 Sq.mm.
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
538
677
846
1003
1240
1567
1909
2440
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
93
121
162
226
291
379
528
675
849
1044
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
140
181
197
272
345
443
591
746
923
Metre
1125
Metre
358
Metre
Metre
408
45982
SOR ELECTRICAL 2014/CHAPTER-41
Page 82 of 114
41.2.1.4
41.2.1.5
41.2.2
41.2.2.1
41.2.2.2
41.2.2.3
41.3
120 Sq.mm.
150 Sq.mm.
SINGLE CORE XLPE CABLE 33 KV GRADE
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
Supply of approved High-Tension XLPE cable (conforming
IS-7098/II/85 ) as per ISI standard 3 core Armoured with
Alu. Solid/stranded conductor ISI MARKED as required
41.3.1
41.3.1.1
41.3.1.2
41.3.1.3
41.3.1.4
41.3.1.5
41.3.2
41.3.2.1
41.3.2.2
41.3.2.3
41.4
3 CORE XLPE CABLE 11 KV GRADE
50 Sq.mm
70 Sq.mm
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
3 CORE XLPE CABLE 33 KV GRADE
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
Supply of XLPE Insulated power cable (conforming IS7098 ) 1100 Volt grade/Heavy duty power cable 2 core / 3
core ISI MARKED with copper Stranded /solid conductor
41.4.1
41.4.1.1
ARMOURED 2 Core
2.5 Sq.mm.(Heavy Duty)
BRASS COMPRESSION GLAND
Supplying and fixing heavy duty cable gland for P.V.C.
insulated armoured cable with brass washer, Rubber ring
complete erected with cable and lead connection etc. as
per specification complete.
41.5
41.5.1
41.5.2
41.5.3
41.5.4
41.5.5
41.5.6
41.5.7
Gland Size 22mm suitable for cable 2,3,3½ & 4 x up to 6
Sq.mm
Gland Size 22mm suitable for cable 2/3, 3½, 2/4 x 10
Sq.mm or 2x 16 Sq.mm
Gland size 28mm for 3/4 x 16 Sq.mm
Gland size 32mm for 2/3, 3½, 4 x 25 Sq.mm
OR 2/3, 3½ x 35 Sq.mm OR 2/3 x 50 Sq.mm.
Gland size 38mm 3½ x 70 Sq.mm, 3x95 Sq.mm
Gland Size 45mm 3/3½ x 120 Sq.mm, 3½ x 95 Sq.mm
3 x 150 Sq.mm.
Gland Size 50 mm 3½ x 150 Sq.mm, 3 x 185 Sq.mm
Metre
Metre
518
571
Metre
Metre
Metre
803
884
945
Metre
Metre
Metre
Metre
Metre
841
999
1193
1377
1537
Metre
Metre
Metre
2057
2362
2562
Metre
176
Each
34
Each
Each
46
70
Each
80
Each
115
Each
137
Each
17783
SOR ELECTRICAL 2014/CHAPTER-41
Page 83 of 114
41.5.8
Gland Size 57mm 3 x 225 Sq.mm, 3 ½ x 185 Sq.mm
41.5.9
Gland Size 70mm 3 x 240 Sq.mm, 3½ x 300 Sq.mm
41.5.10
41.6
41.6.1
41.6.2
41.6.3
41.6.4
41.6.5
41.6.6
41.6.7
41.6.8
41.6.9
41.6.10
41.6.11
41.6.12
41.6.13
41.6.14
41.7
41.7.1
41.7.2
41.7.3
41.7.4
41.7.5
41.7.6
41.7.7
41.7.8
41.7.9
41.7.10
Each
244
Each
Gland Size 82mm 3½ x 400 Sq.mm
Each
Supplying and fixing ferrules as per IS - specification
suitable for following size of cable for circuit identification
including connection as required complete
333
433
For Conductor Size2.5 to 6.00 Sq.mm
10.00 Sq.mm
16.00 Sq.mm
25.00 Sq.mm
35.00 Sq.mm
50.00 Sq.mm
70.00 Sq.mm
95.00 Sq.mm
120.00 Sq.mm
150.00 Sq.mm
185.00 Sq.mm
240.00 Sq.mm
300.00 Sq.mm
400.00 Sq.mm
LUGS:Supplying and fixing cramping type Alum. lugs as per
I.S.S.
Specification suitable for following size of cable with Alu.
/Copper solid/stranded conductor evently cramped with
high/pressure
tool
and
connected
to
switch
gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.
For Conductor Size6mm to 16 Sq.mm
25 Sq.mm
35 Sq.mm
50 Sq.mm
70 Sq.mm
95 Sq.mm.
120 Sq.mm.
150 Sq.mm.
180 Sq.mm
240 Sq.mm.
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
1
2
2
3
3
5
8
9
13
18
22
36
52
75
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
2
4
5
8
11
16
21
30
40
5584
SOR ELECTRICAL 2014/CHAPTER-41
Page 84 of 114
41.7.11
41.7.12
41.8
300 Sq.mm.
Each
400 Sq.mm.
Each
Supplying & fixing pin terminal lugs as per ISS
specification suitable for cable evently cramped with high
pressure tool & connection to switch gear terminal.
41.8.1
41.8.1.1
Aluminum Lugs Pin Type
Up to 16 Sq.mm2 Conductor Size
Up to 25 Sq.mm2 Conductor Size
35 Sq.mm Conductor Size
Copper Lugs Pin Type
Up to 16 Sq.mm2 Conductor Size
Up to 25 Sq.mm2 Conductor Size
35 Sq.mm Conductor Size
Aluminum Lugs Tube Type
Up to 16 Sq.mm Conductor Size
25 Sq.mm Conductor Size
35 Sq.mm Conductor Size
50 Sq.mm. Conductor Size
Copper Lugs Tube Type
Up to 16 Sq.mm2 Conductor Size
25 Sq.mm2 Conductor Size
35 Sq.mm Conductor Size
50 Sq.mm. Conductor Size
Cable Jointing
Providing & Making cable end termination with HEAT
SHRINKABLE jointing kit complete with all accessories
including lugs suitable for 33 kV/11 kV single core XLPE
alum. conductor cable as required as per specification and
as per accepted standard including connection testing
complete.
Heat shrinkable joint,kit 11 kV XLPE Single Core
Heat shr.jointg. kit 11 kV XLPE cable O.D. termination
a. 1 x 16-35 sq.mm.
b. 1 x 50-95 sq.mm.
c. 1 x 120-185 sq.mm.
Heat shr.jointg. kit 11 kV XLPE cable I.D. termination
a. 1 x 16-35 sq.mm.
b. 1 x 50-95 sq.mm.
c. 1 x 120-185 sq.mm.
41.8.1.2
41.8.1.3
41.8.2
41.8.2.1
41.8.2.2
41.8.2.3
41.8.3
41.8.3.1
41.8.3.2
41.8.3.3
41.8.3.4
41.8.4
41.8.4.1
41.8.4.2
41.8.4.3
41.8.4.4
41.9
41.9.1
41.9.1.1
41.9.1.2
72
115
Each
Each
7
8
11
Each
Each
Each
17
26
28
Each
Each
Each
Each
1
3
5
8
Each
Each
Each
Each
6
11
15
23
Each
Each
Each
4082
4361
4770
Each
Each
Each
2944
2988
339585
Each
SOR ELECTRICAL 2014/CHAPTER-41
Page 85 of 114
41.9.1.3
41.9.2
41.9.2.1
41.9.2.2
41.9.2.3
41.10
41.10.1
41.10.1.1
41.10.1.2
41.10.1.3
41.10.2
41.10.2.1
Heat shr.jointg. kit 11 kV XLPE cable Straight Through
termination
a. 1 x 16-35 sq.mm.
b. 1 x 50-95 sq.mm.
c. 1 x 120-185 sq.mm.
Heat shrinkable joint,kit 33 kV XLPE Single Core
Heat shr.jointg. kit 33 kV XLPE cable O.D. termination
a. 1 x 35-70 sq.mm.
b. 1 x 95-150 sq.mm.
c. 1 x 185-240 sq.mm.
Heat shr.jointg. kit 33 kV XLPE cable I.D. termination
a. 1 x 35-70 sq.mm.
b. 1 x 95-150 sq.mm.
c. 1 x 185-240 sq.mm.
Heat shr.jointg. kit 33 kV XLPE cable Straight Through
termination
a. 1 x 35-70 sq.mm.
b. 1 x 95-150 sq.mm.
c. 1 x 185-240 sq.mm.
Providing & Making cable end termination with HEAT
SHRINKABLE jointing kit complete with all accessories
including lugs suitable for 33 kV/11 kV 3 core XLPE alum.
conductor cable as required as per specification and as
per accepted standard including connection testing
complete.
Heat shrinkable joint,kit 11 kV XLPE, 3 Core
Heat shr.jointg. kit 11 kV XLPE cable O.D. termination
a. 3 x 16-35 sq.mm.
b. 3 x 50-95 sq.mm.
c. 3 x 120-185 sq.mm.
Heat shr.jointg. kit 11 kV XLPE cable I.D. termination
a. 3 x 16-35 sq.mm.
b. 3 x 50-95 sq.mm.
c. 3 x 120-185 sq.mm.
Heat shr.jointg. kit 11 kV XLPE cable Straight Joint
a. 3 x 16-50 sq.mm.
b. 3 x 70-95 sq.mm.
c. 3 x 120-185 sq.mm.
Heat shrinkable joint,kit 33 kV XLPE, 3 Core
Each
Each
Each
7170
8353
9203
Each
Each
Each
7121
7959
8770
Each
Each
Each
4484
5270
7063
Each
Each
Each
17428
21861
25908
Each
Each
Each
10355
11768
13078
Each
Each
Each
13570
14906
15691
Each
Each
Each
20106
22009
26902
Heat shr.jointg. kit 33 kV XLPE cable O.D. termination86
SOR ELECTRICAL 2014/CHAPTER-41
Page 86 of 114
41.10.2.2
41.10.2.3
41.11
41.11.1
41.11.2
41.11.3
41.11.4
a. 3 x 35-70 sq.mm.
b. 3 x 95-150 sq.mm.
c. 3 x 185-240 sq.mm.
Heat shr.jointg. kit 33 kV XLPE cable I.D. termination
a. 3 x 35-70 sq.mm.
b. 3 x 95-150 sq.mm.
c. 3 x 185-240 sq.mm.
Heat shr.jointg. kit 33 kV XLPE cable Straight Joint
a. 3 x 35-70 sq.mm.
b. 3 x 95-150 sq.mm.
c. 3 x 185-240 sq.mm.
Supply and making cable straight joint / end termination
with HEAT SHRINKABLE jointing kit complete with all
accessories including lugs suitable for 1.1 kV XLPE/HD
alum. conductor cable as required as per specification and
as per accepted standard including connection testing
complete for (I.D../O.D.) termination.
Heat shr.jointg. kit 1.1 kV XLPE/HD cable end termination
jointing.kit (I.D../O.D.)
a. 6-16 sqmm 1 core
b. 25-50 sqmm 1 core
c. 70-150 sqmm 1 core
d. 185-300 sqmm 1 core
e. 400-500 sqmm 1 core
Heat shr.jointg. kit 1.1 kV XLPE/HD cable straight through
jointing.kit (I.D../O.D.)
a. 6-16 sqmm 1 core
b. 25-50 sqmm 1 core
c. 70-150 sqmm 1 core
d. 185-300 sqmm 1 core
e 400-500 sqmm 1 core
Heat shr.jointg. kit 1.1 kV XLPE/HD cable I.D/O.D. end
ternmination
a. 6-50 sqmm 3 core
b. 70-150 sqmm 3 core
c. 185-300 sqmm 3 core
d. 400-500 sqmm 3 core
Heat shr.jointg. kit 1.1 kV XLPE/HD cable I.D./O.D. end
ternmination87
Each
Each
Each
21158
25166
31337
Each
Each
Each
16745
17405
24135
Each
Each
Each
47950
59503
81057
Each
Each
Each
Each
Each
455
515
704
1074
1290
Each
Each
Each
Each
Each
851
921
1131
1337
1548
Each
Each
Each
Each
1665
1939
2534
3072
SOR ELECTRICAL 2014/CHAPTER-41
Page 87 of 114
41.12.1
41.12.1.1
41.12.1.2
41.12.1.3
41.12.1.4
41.12.1.5
41.12.1.6
41.12.1.7
a. 6-50 sqmm 4 core
b. 70-150 sqmm 4 core
c. 185-300 sqmm 4 core
d. 400-500 sqmm 4 core
Heat shr.jointg. kit 1.1 kV XLPE/HD cable straight through
jointing.kit (I.D../O.D.)
a. 6-16 sqmm 3½ / 4core
b. 25-35 sqmm 3½ / 4core
c. 50-95 sqmm 3½ / 4core
d. 120-185 sqmm 3½ / 4core
e. 225-300 sqmm 3½ / 4core
f. 400-500 sqmm 3½ / 4core
Suppying & installing G.I. Pipe for protection of
underground cable fixed on wall/support/in trench/fixed
between two rigid existing support of wall/beam for
erection of ceiling Fan/down rod for stiff pendent for light
luminaries /fan/protective for earthing, lightening conductor
down strip/overhead service line/for submersible cable or
centrifugal pump for water supply with necessary iron
clamp coupler, bend, tee, elbow, nuts and bolts etc.
complete in an approved manner as required to complete
excluding cost of excavation/dismentalling & other finshed
masonary Item complete.
For 'B' Class pipe ISI Marked (IS-1161-68)
15mm
20.00mm
25.00mm
32.00mm
40.00mm
50.00mm
65.00mm
41.12.1.8
41.12.1.9
41.12.1.10
41.12.2
80.00mm
100.00mm
150.00mm
A' Class G.I.Pipe ISI Marked (IS-1161-69)
41.12.2.1
41.12.2.2
41.12.2.3
41.12.2.4
41.12.2.5
15mm
19/20mm
25.00mm
32.00mm
40.00mm
41.11.5
41.12
Each
Each
Each
Each
1817
2120
2685
3292
Each
Each
Each
Each
Each
Each
1610
1947
2583
3437
4910
7176
Metre
Metre
Metre
Metre
Metre
Metre
130
168
239
301
351
465
Metre
Metre
Metre
Metre
586
761
1070
1753
Metre
Metre
Metre
Metre
Metre
111
155
210
271
32788
SOR ELECTRICAL 2014/CHAPTER-41
Page 88 of 114
41.12.2.6
41.12.2.7
41.12.2.8
41.12.2.9
41.13
41.13.1
50.00mm
65.00mm
80.00mm
100.00mm
Supply and laying rigid PVC single socket and, nonmetallic pipe ISI Marked (IS-4985-2000) 10 Kg/sq.cm class
5 for protection of under ground cable/or for water pump
delivery side, for water supply complete with necessary
clamp coupler, band, Tee, Elbow etc. in an approved
manner excluding cost of excavation etc.
50.00mm O.D
41.13.2
41.13.3
41.13.4
41.13.5
41.14
75.00mm O.D
110.00mm O.D
160.00mm O.D
200.00mm O.D
Supplying and installing Double wall corrugated pipes
(DWC) of HDPE ( IS 14930 Part II -marked ) for cable laid
under ground with necessary material and at required
depth upto 90cm. below road/ground surface, including
excavation, back filling with excavated material, ramming
and making the surface good.
41.14.1
41.14.2
41.14.3
41.14.4
41.14.5
41.14.6
41.14.7
50.00mm outside dia.
63.00mm outside dia.
90.00mm outside dia.
110.00mm outside dia.
120.00mm outside dia.
180.00mm outside dia.
210.00mm outside dia.
CABLE LAYING
Laying of one number armoured / unarmoured power
cable 1.1kV grade of size not exceeding 25 Sq.mm direct
in ground including excavation in all soil / murrum / soft
rock, sand cushioining, protective covering and refilling the
pit etc. as required.
Laying of one number armoured / unarmoured power
cable 1.1.kV grade of size exceeding 25Sq.mm but not
exceeding 120 Sq.mm direct in ground including
excavation in all soil / murrum / soft rock, sand cushioing,
protective covering and refilling the pit etc. as required.
Laying of one number armoured / unarmoured cable
1.1.kV grade of size exceeding 120 Sq mm but not
exceeding
400 Sq.mm direct in ground including
excavation in all soil / murrum / soft rock, and sand
41.15
41.16
41.17
Metre
Metre
Metre
Metre
414
547
658
920
Metre
Metre
Metre
Metre
Metre
127
295
645
1274
1978
Metre
Metre
Metre
Metre
Metre
Metre
Metre
137
180
233
264
299
412
554
Metre
202
Metre
21189
Metre
229
SOR ELECTRICAL 2014/CHAPTER-41
Page 89 of 114
cushioning protective covering and refilling the pit etc. as
required.
41.18
41.19
41.20
41.21
41.22
41.23
41.24
41.25
Laying of one number additional armoured / unarmoured
power cable 1.1kV grade of size not exceeding 25Sq.mm
direct in ground in the same trench in one tier horizontal
formation including excavation in all soil / murrum / soft
rock, sand cushioing protective covering and refilling the
pit etc. as required.
Laying of one number additional armoured / unarmoured
power cable 1.1kV grade of size exceeding 25 Sq.mm but
not exceeding 120 Sq.mm direct in ground in the same
trench in one tier horizotal formation including excavation,
sand cushioing, protective covering and refilling the pit etc.
as required.
Laying of one number additional armoured / unarmoured
power cable 1.1kV grade of size exceeding 120 Sq mm
but not exceeding 400 Sq mm direct in ground in the same
trench in one tier horizotal formation including excavation,
sand cushioing, protective covering and refilling the pit etc.
as required.
Laying of one number armoured / unarmoured power
cable 1:1 kV grade of size not exceeding 25 Sq.mm in the
existing RCC Hume/Stone ware/G.I. pipe / surface in
existing trench as required.
Laying of one number armoured / unarmoured power
cable 1.1 kV grade of size exceeding 25 Sq.mm but not
exceeding 400 Sq mm in the existing RCC Hume /Stone
ware/G.I. Pipe/ surface in existing trench as required.
Metre
111
Metre
120
Metre
138
Metre
25
Metre
43
Laying of one number armoured / unarmoured power
cable 1.1 kV grade of size not exceeding 25 Sq.mm in th
existing masonary open duct as required.
Metre
Laying of one number armoured / unarmoured power
cable 1.1kV grade of size exceeding 25Sq.mm but not
exceeding 400 Sq.mm in the existing masonary open duct
as required.
Metre
Laying of one number single core H.T armoured /
unarmoured power cable of grade exceeding 1.1kV but not
exceeding 11kV of size not exceeding 150 Sq.mm direct in
ground including excavation in all soil / murrum / soft rock,
sand cushioning, excluding protective covering and refilling
the trench etc. as required.
Metre
20
43
13890
SOR ELECTRICAL 2014/CHAPTER-41
Page 90 of 114
41.26
41.27
41.28
41.29
41.30
41.31
41.32
41.33
41.34
41.35
Laying of one number single core H.T armoured /
unarmoured power cable of grade 33kV of size not
exceeding 150 Sq.mm
direct in ground including
excavation sand cushioning, excluding protective covering
and refilling the trench etc. as required
Metre
Laying of one number single core H.T armoured /
unarmoured power cable of grade exceeding 1.1kV but not
exceeding 11kV of size not exceeding 150 Sq.mm in the
existing RCC / Hume / Stoneware / G.I. Pipe / surface in
existing trench as required.
Metre
Laying of one number single core H.T armoured /
unarmoured power cable of grade exceeding 1.1kV but not
exceeding 11kV of size not exceeding 150 Sq.mm. in the
existing masonary open duct as requied.
Metre
Laying of one number single core H.T armoured /
unarmoured power cable 33kV grade of size not
exceeding 150 Sq.mm in the existing RCC / Hume /
Stoneware / G.I. Pipe / surface in existing trench as
required.
Metre
Laying of one number single core H.T armoured /
unarmoured power cable 33kV grade of size not
exceeding 150 Sq.mm. in the existing masonary open duct
as requied.
Metre
Laying of one number single core H.T armoured /
unarmoured power cable 11kV grade of size not
exceeding 150 Sq.mm on wall / pole etc. as required.
Metre
Laying of one number single core H.T armoured /
unarmoured power cable 33kV grade of size not
exceeding 150 Sq.mm on wall / pole etc. as required.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable of grade exceeding 1.1kV but not exceeding
11kV of size not exceeding 150 Sq.mm direct in ground
including excavation in all soil / murrum / soft rock, sand
cushioning, excluding protective covering and refilling the
trench etc. as required.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable of grade 33kV of size not exceeding 150
Sq.mm direct in ground including excavation in all soil /
murrum / soft rock, sand cushioning, excluding protective
covering and refilling the trench etc. as required
Metre
Laying of one number additional 3 core H.T armoured /
unarmoured power cable of grade exceeding 1.1kV but not
exceeding 11kV of size not exceeding 150 Sq.mm direct in
ground in the same trench in one tier horizontal formation
including sand cusioning, excluding protective covering
and refilling the trench as required.
Metre
138
27
31
31
36
63
22
188
19791
130
SOR ELECTRICAL 2014/CHAPTER-41
Page 91 of 114
41.36
41.37
41.38
41.39
41.40
41.41
41.42
41.43
41.44
41.45
41.46
Laying of one number additional 3 core H.T armoured /
unarmoured power cable 33kV grade of size not
exceeding 150 Sq.mm direct in ground in the same trench
in one tier horizontal formation including sand cushioning,
excluding protective covering and refilling the trench etc.
as requied.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable of grade exceeding 1.1kV but not exceeding
11kV of size not exceeding 150 Sq.mm in the existing
RCC / Hume / Stoneware / G.I. Pipe / surface in existing
trench as required.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable of grade exceeding 1.1kV but not exceeding
11kV of size not exceeding 150 Sq.mm. in the existing
masonary open duct as requied.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable 11kV grade of size not exceeding 150 Sq.mm
on wall / pole etc. as required.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable 33kV grade of size not exceeding 150 Sq.mm
in the existing RCC / Hume / Stoneware / G.I. Pipe /
surface in existing trench as required.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable 33kV grade of size not exceeding 150
Sq.mm. in the existing masonary open duct as requied.
Metre
Laying of one number 3 core H.T armoured / unarmoured
power cable 33kV grade of size not exceeding 150 Sq.mm
on wall / pole etc. as required.
Metre
Laying of one number armoured / unarmoured cable 1.1kV
grade of size not exceeding 25 Sq.mm on surface in
existing trench etc. as required.
Metre
Laying of one number armoured / unarmoured cable
1.1kV grade of size exceeding 25 Sq.mm but not
exceeding 120 Sq.mm on surface in existing trench etc.
as required.
Metre
Laying of one number armoured / unarmoured cable
1.1kV grade of size exceeding 120 Sq.mm but not
exceeding 400 Sq.mm on surface in existing trench etc.
as required.
Metre
Excavation of the trenches in Hard Rock not exceeding 1.5
metre in width and lift upto 1.5 metre including getting out
the excavated metal and disposal of surplus excavated
soil/metal as directed within the lead of 50 metre (without
blasting)
Cu. Mtr.
139
52
52
108
52
52
52
20
34
43
50692
SOR ELECTRICAL 2014/CHAPTER-41
Page 92 of 114
41.47
41.48
41.49
41.50
41.50.1
41.50.2
41.50.3
41.51
41.52
41.53
41.54
41.54.1
41.54.2
41.54.3
41.54.4
41.54.5
Laying of one number armoured / unarmoured cable 1.1kV
grade of size not exceeding 25 Sq.mm on wall/truss with
approved type of iron clamps etc. as required.
Metre
Laying of one number armoured / unarmoured cable
1.1kV grade of size exceeding 25 Sq.mm but not
exceeding 120 Sq.mm on wall/truss with approved type of
iron clamps etc. as required.
Metre
Laying of one number armoured / unarmoured cable
1.1kV grade of size exceeding 120 Sq.mm but not
exceeding 400 Sq.mm on wall/truss with approved type of
iron clamps etc. as required.
Metre
Laying of underground cable armoured./ unarmoured as
per specification in air suspended on existing approved
type of iron clamps, G.I wire 7/1.6mm & shackle insulator /
insulated strip complete.
1/2 / 3 / 4 Core cable up to 16 Sq.mm
1 / 2 / 3 / 3½ / 4 Core cable 25 Sq.mm to 120 Sq.mm
1 / 2 / 3 / 3½ / 4 Core cable 150 Sq.mm and above
Laying of cement concrete or approved type of cable
cover/flag stone over L.T. / H.T. cable & refill trench as per
specification.
Supply of approved type cable cover flag stone 200mm
width & 32mm to 50mm thick of required length inclusive
of transport as required.
Supply & Fixing Cable Route Marker round / square size
100mm, 5mm. Thick, G.I. Plate duly bolted/welded on
35mm x 35mm x 5mm angle iron 60cm long including
excavation, grouting in cement concrete 1:2:4 (1cement
and 2 coarse sand :4 graded stone aggregate 20mm
nominal size) foundation of size 20cm x 20cm x 30cm duly
embedded in ground 30cm depth or as required.
Supply and erection of hot dip G.I. cable tray perforation
not more than 17.5% for specific dimensions along with
tees, bends.. The cable tray shall be hang from ceiling/
fixed to wall with necessary angle/flat iron / hanging rod,
for ceiling suspensions, clamps, anchor fastner, nuts,
bolts, washers, not mor than 1.5 mtr. apart complete as
per specification to complete the job. The tray shall be as
follows :100 x 50 mm x 1.6mm thick
150 x 50 mm x 1.6mm thick
300 x 50 mm x 1.6mm thick
450 x 50 mm x 2 mm thick
600 x 50 mm 2 mm thick
40
90
105
Metre
Metre
Metre
11
20
34
Metre
11
Metre
45
Each
per Mtr
per Mtr
per Mtr
per Mtr
per Mtr
250
495
572
844
1296
160393
SOR ELECTRICAL 2014/CHAPTER-41
Page 93 of 114
CHAPTER-42 (External)
EXTERNAL ELECTRIFICATION AND OVERHEAD LINES
S.No.
Description of Item
42.1
SUPPORT FOR OVER HEAD LINE
Supply of support for overhead line Rail pole of I.S.
standard including base plate, welding, drilling of required
hole etc. complete as required.
42.1.1
42.1.2
42.2
42.2.1
42.2.2
42.2.3
42.2.4
42.2.5
42.2.6
42.3
42.3.1
42.3.2
42.3.3
42.3.4
42.3.5
42.3.6
42.3.7
42.3.8
42.3.9
42.3.10
42.3.11
42.3.12
42.3.13
42.3.14
42.3.15
42.3.16
42.3.17
Rail pole standard weight 60 kg/per metre
Rail pole standard weight 52 kg/per metre
Supply of support for overhead line RS joist /'H' Beam of
I.S. standard including drilling of required hole etc. complete
as required.
R.S. Joist 100x200-25.4 kg/per metre
R.S. Joist 175 x 85 - 19.3 kg/per metre
R.S. Joist 150 x 100 - 17 kg/per metre
R.S. Joist 150 x 80 - 14.9 kg/per metre
R.S. Joist 125 x 75 - 13 kg/per metre
H - Beam 152 x 152mm, Std weight 37.1 Kg / Mtr
Supply of steel tubular pole swaged type as per IS:27131980 Complete with base plate and top Canopy
410 SP-2 - 7.00 metre
410 SP-5 - 7.50 metre
410 SP-8 - 7.50 metre
410 SP-11 - 8.00 metre
410 SP-14 - 8.00 metre
410 SP-17 - 8.50 metre
410 SP-20 - 8.50 metre
410 SP-23 - 8.50 metre
410 SP-26 - 9.00 metre
410 SP-29 - 9.00 metre
410 SP-32 - 9.00 metre
410 SP-35 - 9.50 metre
410 SP-38 - 9.50 metre
410 SP-41 - 10.00 metre
410 SP-44 - 10.00 metre
410 SP-47 - 10.00 metre
410 SP-50 - 11.00 metre
Unit
Rate
Metre
Metre
4116
3568
Metre
Metre
Metre
Metre
Metre
Metre
1678
1275
1123
984
859
2545
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
7968
8623
11242
9059
12115
9714
12552
16154
10042
13643
16809
14080
17464
14735
18337
24122
1604594
SOR ELECTRICAL 2014/CHAPTER-42
Page 94 of 114
42.3.18
42.3.19
42.3.20
42.3.21
42.3.22
42.3.23
42.3.24
42.3.25
42.3.26
42.3.27
42.3.28
42.3.29
42.3.30
42.3.31
42.3.32
42.3.33
42.3.34
42.4
42.4.1
42.4.2
42.5
42.5.1
42.5.2
42.5.3
42.5.4
42.6
42.6.1
42.6.2
42.6.3
42.6.4
42.6.5
42.7
410 SP-53 - 11.00 metre
410 SP-56 - 11.00 metre
410 SP-59 - 12.00 metre
410 SP-62 - 12.00 metre
410 SP-65 - 12.00 metre
410 SP-68 - 13.00 metre
410 SP-71 - 13.00 metre
410 SP-73 - 14.50 metre
410 SP-76 - 14.50 metre
410 SP-77 - 16.00 metre
410 SP-80 - 16.00 metre
410 SP-10 (Bend type) 8.00 metre
410 SP-16 (Bend type) 8.50 metre
410 SP-25 (Bend type) 9.00 metre
410 SP-34 (Bend type) 9.50 metre
410 SP-40 (Bend type) 10.00 metre
410 SP-49 (Bend type) 11.00 metre
Supplying of prestressed cement concrete (PCC) pole
conforming to IS: 785 at work site including required
transportation.
PCC pole 8 mtrs. Long 140 kg
PCC pole 9.1 mtrs. Long 280 kg
Supplying and drawing All Aluminum Alloy conductor
(AAAC) of approved make confirming to IS 398-1979 Pt. IV,
including binding at existing insulator, jointing, jumpering,
tearing off, connecting etc. as required including clearing of
obstacles (if any)
AAAC 0.03 sq inch (34 Sq.mm Al. EQ. ) - (Weasel)
AAAC 0.05 sq inch (55 Sq.mm Al. EQ. ) - (Rabbbit)
AAAC 0.075 sq inch (80 Sq.mm Al. EQ. ) - (Raccoon)
AAAC 0.1 sq inch (100 Sq.mm Al. EQ. ) - (Dog)
Supplying and drawing of stranded Aluminium Conductor
Steel Reinforced (ACSR) confirming to IS:398-1976 of
approved make, stringing, making off complete with binding
at existing insulator, jointing, jumpering, tearing off,
connecting etc. as required and clearing of obstacles (if
any) etc.
ACSR 0.02 Sq inch (20 Sq.mm Al. EQ. ) - (Squirrel)
ACSR 0.03 sq inch (34 Sq.mm Al. EQ. ) - (Weasel)
ACSR 0.05 sq inch (55 Sq.mm Al. EQ. ) - (Rabbit)
ACSR 0.075 sq inch (80 Sq.mm Al. EQ. ) - (Raccoon)
ACSR 0.1 sq inch (100 Sq.mm Al. EQ. ) - (Dog)
Supplying and fixing guard insulator or split insulator
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
Each
19974
26305
21502
28269
34163
30670
36346
34054
41476
37219
45405
7640
8186
8514
13316
13971
15281
Each
Each
2033
3812
Km.
Km.
Km.
Km.
30876
51356
64688
77891
Km.
Km.
Km.
Km.
Km.
32227
39602
49132
73831
8934695
SOR ELECTRICAL 2014/CHAPTER-42
Page 95 of 114
42.7.1
42.7.2
42.7.3
42.8
42.9
42.10
42.11
42.11.1
42.11.2
42.11.3
42.12
42.12.1
42.12.2
42.13
42.14
complete:
25x25mm
Pair
37x37mm
Pair
50x50mm
Pair
Supplying and drawing guard wire/earth wire/bearer wire
13mm2 (4mm. Dia) G.I. including stringing, binding at
existing insulators or brackets, jointing, jumpering,
connecting & cradle etc. as required and clearing of
obstacles (if any)
Km.
Supplying and drawing guard wire/earth wire/bearer wire
18.62 mm2 (4.87mm. Dia / 6swg) G.I. including stringing,
binding at existing insulators or brackets, jointing,
jumpering, connecting & cradle etc. as required and clearing
of obstacles (if any)
Km.
Supplying and drawing G.I. bearer wire 7/1.6mm including
stringing, binding at existing brackets / pole, etc. for cable
support in air as required and clearing of obstacles (if any)
PM
Supplying and erection of guards for existing overhead lines
as required including split insulator required as per
specification:
Cradle type
Each
Hexagonal type
Each
Ring type
Each
Supplying and erection of water tight terminal box made of
16 SWG M.S. Sheet (1.6mm thick) i/c rubber gasket of
required size suitable for kit kat/ MCB/ Switch including 2
Nos. pole clamp of M.S. flat iron size 32x3mm, nut and
bolts, 4 Pole epoxy connector nut & bolt type, 30Amp.,
500Volt. The box shall be powder coated. Excluding the
cost of the Kit Kat/MCB/Switch complete as per
specification.
20x15x10Cms.
Each
30x20x10 Cms.
Each
Erection of RS Joist pole / 'H' Beam / steel tubular / steel rail
pole of length 7 metres but not exceeding 10 metres in
cement concrete 1:3:6 (1 cement : 3 core sand: 6 graded
stone aggregate 40mm nominal size) base, foundation,
muffing including excavation and back refilling etc. as
required.
Each
Erection of RS Joist pole / 'H' Beam / steel tubular / steel rail
pole of length exceeding 10 metres but not exceeding 13
metres in cement concrete M-10 (1 cement:3 core sand: 6
graded stone aggregate 40mm nominal size) base,
foundation, muffing including excavation and back refilling
etc. as required.
Each
21
26
33
14690
17198
17
25
18
16
730
971
3316
402796
SOR ELECTRICAL 2014/CHAPTER-42
Page 96 of 114
42.15
42.16
42.17
42.18
42.19
42.20
42.21
Erection of R.C.C./P.C.C. pole of length 8 metres but not
exceeding 11 metres in brick ballast and ramming the
foundation including excavation and refilling etc.as required. Each
Erection of metallic street light pole length upto 2 metres in
cement concrete M-10 (1cement:3coarse sand:6 graded
stone aggregate 40mm nominal size) foundation with
cement concrete coller of size 0.4 metres dia x 0.3 metres
height to accommodate the looping type cable end box
including excavation and refilling etc. as required.
Each
Erection of metallic street light pole length 3 metres but not
exceeding 6 metres in cement concrete M-10
(1cement:3coarse sand:6 graded stone aggregate 40mm
nominal size) foundation with cement concrete coller of size
0.4 metres dia x 0.5 metres height to accommodate the
looping type cable end box including excavation and refilling
etc. as required.
Each
Erection of RS Joist pole / 'H' Beam / steel tubular / steel rail
pole strut in cement concrete 1:3:6 (1cement:3coarse sand:
6 aggregate 40mm nominal size) foundation including
excavation and refilling and secured with holding clamps,
nuts and bolts, etc. as required.
Each
Erection of RCC/PCC pole strut in brick ballast and
ramming the foundation including excavation and refilling
and secured with holding clamps nuts and bolts etc. as
required.
Each
Supplying and erection of stay set complete (Galvanized)
19mm. Dia x 1.8 metre long stay rod anchor plate of size
300 mm x 300 mm x7.5mm, thimble, stay clamps, turn
buckle (19mm dia x 600mm),7/4.00mm dia G.I. Stay wire
etc. in cement concrete M-10 (1 Cement : 3 Coarse sand :
6 graded stone aggregate 40mm nominal size) foundation
including excavation and refilling etc. as required.
Each
Supplying and erection of stay set complete (Galvanized)
with 16mm dia x1.8 metre long stay anchor plate of size
200mm x 200mm x 6.0mm, thimble, stay clamps, turn
buckle 19mmx600mm, 7/3.15mm dia G.I. stay wire etc. in
cement concrete M-10 (1 Cement : 3 Coarse and : 6
granded stone aggregate 40mm nominal size) foundation
including excavation and refilling etc. as required.
Each
1555
1027
1935
2844
1608
3906
313097
SOR ELECTRICAL 2014/CHAPTER-42
Page 97 of 114
42.22
Supplying and erection of stay set complete with
19/20mm.dia 1.8 metre long stay rod, turn buckle, ancher
plate of size 300mm x 300mm x 7.5mm, thimble, stay
clamps, bow tightener, 7/4.00 dia G.I. stay wire etc. in
cement concrete M-10 (1 Cement : 3 Coarse and : 6
granded stone aggregate 40mm nominal size) foundation
including excavation and back refilling etc. as required.
42.23
Supplying and erection of stay set complete with 16mm.dia
1.8 metre long stay rod, turn buckle, anchor plate of size
200mm x 200mm x 6.0mm, thimble ,stay clamps, bow
tightener, 7/3.15 dia G.I. stay wire etc. in cement concrete
M-10 (1 Cement : 3 Coarse and : 6 graded stone aggregate
40mm nominal size) foundation including excavation and
back refilling etc. as required.
42.24
42.25
42.26
42.27
Each
3775
Each
2994
Each
Supplying and erection of bow stay set complete
(galvanized) with 19mm dia x 1.8m long stay rod, anchor
plate of size 300mmx300mm x 7.5mm, thimble, stay
clamps, turn buckle 19mmx600mm, 7/4.00mm dia G.I. stay
wire and bow tightener, etc. in cement concrete M-10 ( 1
Cement : 3 coarse sand : 6 graded stone aggregate 40mm
nominal size) foundation including excavation and back
refilling and also with 0.6m long brace of size 50mmx
50mmx6mm angle iron with 50mm dia pulley fixed at one
end of the brace as required.
Each
Supplying and erection of bow stay set complete
(galvanized) wiith 16mm dia. X 1.8m long stay rod, anchor
plate of size 200mmx200mmx6.0mm, thimble, stay clamps,
turn buckle 19mmx600mm, 7/3.15 mm dia G.I. Stay wire
and bow tightener, etc. in cement concrete M-10 (1cement :
3 coarse sand : 6 graded stone aggregate 40mm nominal
size) foundation including excavation and back refilling and
also with 0.6m long brace of size 50mmx50mmx6mm angle
iron with 50mm dia pulley fixed at one end of the brace as
required.
Each
Supplying and erection of bow stay set complete with 19mm
dia x 1.8m long stay rod, anchor plate of size
300mmx300mm x 7.5mm, thimble, stay clamps, turn buckle
19mmx600mm, 7/4.00mm dia G.I. stay wire and bow
tightener, etc. in cement concrete M-10 ( 1 Cement : 3
coarse sand : 6 graded stone aggregate 40mm nominal
size) foundation including excavation and back refilling and
also with 0.6m long brace of size 50mmx 50mmx6mm angle Each
1818
Erection of stay set complete in cement concrete M-10 (1
Cement : 3 coarse sand : 6 graded stone aggregate 40mm
nominal size) foundation including excavation and back
refilling etc. as required.
4185
340898
4054
SOR ELECTRICAL 2014/CHAPTER-42
Page 98 of 114
iron with 50mm dia pulley fixed at one end of the brace as
required.
42.28
42.29
42.30
42.31
42.32
42.33
42.34
42.35
42.36
Supplying and erection of bow stay set complete wiith
16mm dia. X 1.8m long stay rod, anchor plate of size
200mmx200mmx6.0mm, thimble, stay clamps, turn buckle
19mmx600mm, 7/3.15 mm dia G.I. Stay wire and bow
tightener, etc. in cement concrete M-10 (1cement : 3 coarse
sand : 6 graded stone aggregate 40mm nominal size)
foundation including excavation and back refilling and also
with 0.6m long brace of size 50mmx50mmx6mm angle iron
with 50mm dia pulley fixed at one end of the brace as
required.
Supplying and erection of 50mm x 65mm shackle insulator
with G.I. bolts, nuts and straps etc. as required.
Supplying and erection of 75mm x 90mm shackle insulator
with G.I. bolts, nuts and straps etc. as required.
Supplying and erection of 100mmx110mm shackle insulator
with G.I. bolts, nuts and straps etc. as required.
Supplying and erection of Aluminium Knob / bobin with nut,
bolts & straps etc. as required.
Supplying and fixing of 19mm/20mm dia. M.S. pipe 1 mtrs.
In length for CFL / LED street light / Bulkhead / water tight
bracket including bending to shape and wiring with
1.5sqmm W.P./PVC wire etc. as required.
Supplying and fixing of 19mm/20mm dia. G.I. pipe 2 mtrs.
Long for CFL / LED street light / Bulkhead / water tight
bracket including bending to shape and wiring with
1.5sqmm W.P./PVC wire etc. as required.
Supplying and fixing of 32mm dia. X 2.00 mtr. Long G.I.
pipe (Medium class) bracket for mounting of fluorescent /
S.V/ M.H/ L.E.D Lamp street light fittings on poles including
bending the pipe to the required shape and wiring with
1.5Sq.mm W.P. / PVC wire etc. as required.
Each
3239
Each
71
Each
78
Each
84
Each
93
Each
245
Each
365
Each
601
Supply, fabrication and erection of Angle/Chanel/Flat iron
fitting for over head line & sub-station etc such as 'D'
bracket, cross arms, top clamp, 'V' cross arms,
Back/Support clamps or other similar work etc. including
nut bolts of required size, making holes, fabrication,
welding, cutting, etc. and painting with one coat of red oxide
paint & two coat of aluminium paint as required as per
specification.
Kg.
8099
SOR ELECTRICAL 2014/CHAPTER-42
Page 99 of 114
42.37
42.38
42.39
42.40
42.41
42.42
42.43
42.44
42.45
42.46
42.47
42.48
42.49
Labour charges for erection of Angle/Chanel/Flat iron fitting
for over head line & sub-station etc such as 'D' bracket,
cross arms, top clamp, 'V' cross arms, Back/Support clamps
or other similar work etc. including nut bolts of required
size, as required as per specification.
Kg.
Supplying and erection of 11kV Porcelain pin insulator
complete with long steel head G.I. pin, nut, washer etc. as
required.
Each
Supplying and erection of 11kV Porcelain disc insulator for
11kV overhead lines with galvanized insulator fittings, ball
and socket type, and complete with galvanized strain clamp,
bolts, nuts washer etc. as required.
Each
Supplying and erection of 33kV Porcelain pin insulator
complete with long steel head G.I. pin, nut, washer etc. as
required
Each
Supplying and erection of a set of three 11kV porcelain disc
insulators for 33kV overhead lines with galvanized insulator
fittings, ball and socket type, and complete with galvanized
strain clamp, bolts, nuts, washers etc. as required.
Each
Supplying and erection of a set of four 11kV porcelain disc
insulators for 33kV overhead lines with galvanized insulator
fittings, ball and socket type, and complete with galvanized
strain clamp, bolts, nuts, washers etc. as required.
Each
Labour for erection of 11/33kV Porcelain pin insulator
complete with hardware as required.
Each
Labour for erection of 11kV Porcelain disc insulator for 11kV
overhead lines complete with hardware as required.
Each
Labour for erection of a set of three/ four 11kV porcelain
disc insulators for 33kV overhead lines complete with
hardware as required.
Each
Supplying and erection of 11kV (5 KN) Polymer pin insulator
complete with long steel head G.I. pin, nut, washer etc. as
required.
Each
Supplying and erection of 11kV (45 KN) Polymer disc
insulator for 11kV overhead lines with galvanized insulator
fittings, ball and socket type, and complete with galvanized
strain clamp, bolts, nuts washer etc. as required.
Each
Supplying and erection of 33kV (10 KN) Polymer pin
insulator complete with long steel head G.I. pin, nut, washer
etc. as required
Each
Supplying and erection of 33kV (45 KN) Polymer disc
insulators for 33KV overhead lines with galvanized insulator
fittings, ball and socket type, and complete with galvanized
strain clamp, bolts, nuts, washers etc. as required.
Each
7
268
497
503
1212
1788
91
91
219
295
404
430100
661
SOR ELECTRICAL 2014/CHAPTER-42
Page 100 of 114
42.50
42.51
42.52
42.53
42.54
42.55
42.56
42.56.1
42.56.2
42.57
42.57.1
42.57.2
Labour for erection of 11/33kV Polymer pin insulator
complete with hardware as required.
Labour for erection of 11/33kV Polymer disc insulators for
11/33KV overhead lines
complete with hardware as
required.
Supplying and erection of single piece non linear resistor
type lighting arrestor (Set of 3 Nos) for 3 wire, 11kV
overhead lines/sub-station with rated voltage of 9kV (rms)
with a nominal discharge current rating of 5 KA and
complete with galvanized clamping arrangement, G.I. bolts,
nuts, washer etc. as required.
Supplying and erection of single piece non-linear resistor
type lightning arrestor (Set of 3 Nos.) for 3 wire, 33kV
overhead lines/sub-station with rated voltage of 30kV (rms)
with a nominal discharge current rating of 5 KA and
complete with galvanized clamping arrangement, G.I. bolts,
nuts, washer etc. as required.
Supplying and erection of single piece non linear resistor
polymer type lighting arrestor (Set of 3 Nos) for 3 wire, 11kV
overhead lines/sub-station with rated voltage of 9kV (rms)
with a nominal discharge current rating of 10 KA and
complete with galvanized clamping arrangement, G.I. bolts,
nuts, washer etc. as required.
Each
91
Each
146
Set
3391
Set
31467
Set
3643
Set
Supplying installing, testing & commissioning of outdoor
H.T., AB switch assembly set gang operated with brass
contact parts, including required GI pipe operating rod,
handle & locking arrangement on On-Off position
conforming to IS complete with required material and
installing on existing DP structure to complete the job as
required as per specification.(Set of 3 nos.)
11 kV, 400A.
set
33kV, 600A.
set
Supplying installing, testing & commissioning D.O. fuse
assembly with brass part contact for 33 or 11/0.4 KV DP
Structure set of 3 Nos. with fuse barrel i/c required fuse
element & other materials as per specification on existing
D.P. structure as required.101
36006
11kV
33kV
3275
14485
Supplying and erection of single piece non-linear resistor
polymer type lightning arrestor (Set of 3 Nos.) for 3 wire,
33kV overhead lines/ sub-station with rated voltage of 27kV
(rms) with a nominal discharge current rating of 10 KA and
complete with galvanized clamping arrangement, G.I. bolts,
nuts, washer etc. as required.
set
set
6843
21291
SOR ELECTRICAL 2014/CHAPTER-42
Page 101 of 114
42.58
42.58.1
42.58.2
42.59
42.59.1
42.59.2
42.60
42.60.1
42.60.2
42.61
42.62
42.63
42.64
42.64.1
42.64.1.1
42.64.1.2
42.64.1.3
42.64.1.4
Supplying & replacement of D.O. fuse barrel with brass
parts for 33 or 11 KV i/c required fuse element according to
load as per specification on existing D.P. structure as
required.
11kV
Each
33kV
Each
Supplying & replacement of D.O. fuse barrel for 33 or 11 KV
as per specification on existing D.P. structure as required.
11kV
33kV
Supplying & replacement of D.O. fuse element according to
load for 33 or 11 KV as per specification on existing D.P.
structure as required.
11kV
33kV
Supply & fixing anti climbing device with 2 ply G.I. barbed
wire 1 Kg. per pole complete as per specification.
Each
Supply, laying and fixing of G.I. earth coil of 4mm dia G.I.
wire having 120 turns of nearly 50mm dia. and 3 mt. long
tail in existing pit duly earthed with pole etc complete as
required as per specification.
Each
Supplying and fixing 33/11/0.4 KV enamel coated danger
board size 200x250mm with clamp on existing HT/LT
structure / poles.
Each
Supplying, installing, testing and commissioning of 11/0.4
K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, out
door type transformer connected delta on H.T. side and
star on L.T. side, hand operated off load Tap changer
switch above 100 kVA, oil conservator with drain valve, plug
63 KVA and above, dehydrating silica gel breather on eye
level, rating and diagram plate, two earthing terminal, lifting
lugs, oil level gauge, drain valve with plug, temperature not
exceeding 50ºC on load, oil filling hole with plug, four
unidirectional roller, arcing horns, explosion vent, terminal
arrangement bushing on H.V. side and cable box on LV
side, first filling of oil upto desired level and transformer
installing on existing structure with all required materials
arrangement as required as per IS specification. Marked ISI
& 3 Star rating
Aluminium wound
25 kVA
Each
63 kVA
Each
100 kVA
Each
200 kVA
Each
295
769
208
249
66
79
126
220
148
82986
142093
200006102
336138
SOR ELECTRICAL 2014/CHAPTER-42
Page 102 of 114
42.64.2
Copper wound
42.64.2.1 200 kVA
42.64.2.2 315 kVA
42.64.2.3 500 kVA
42.65
Supplying, installing, testing and commissioning of 33/0.4
K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, out
door type transformer connected delta on H.T. side and
star on L.T. side, hand operated off load Tap changer
switch above 100 KVA, rating and diagram plate, two
earthing terminal, lifting lugs, oil level gauge, drain valve
with plug, temperature not exceeding 50ºC on load, oil
conservator with drain plug, oil filling hole with plug,
dehydrating silica gel breather on eye level, four
unidirectional roller, arcing horns, explosion vent, terminal
arrangement bushing on H.V. side and cable box on LV
side, first filling of oil up to desired level and transformer
installing on existing structure with all required materials
arrangement as required as per IS specification. Marked ISI
& 3 Star rating
42.65.1
Copper wound
42.65.1.1 100 KVA
42.65.1.2 200 KVA
42.65.1.3 315 KVA
42.65.1.4 500 KVA
42.66
Supplying, installing, testing and commissioning of 33/0.4
K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, out
door type transformer connected delta on H.T. side and
star on L.T. side, hand operated off load Tap changer
switch, rating and diagram plate, two earthing terminal,
lifting lugs, oil level gauge drain valve with plug,
temperature not exceeding 50ºC on load, temperature dial
gauge, bucholz relay, oil conservator with drain plug, oil
filling hole with plug, dehydrating silica gel breather on eye
level, four unidirectional roller, arcing horns, explosion vent,
terminal arrangement bushing on H.V. side and cable box
on LV side, first filling of oil up to desired level and
transformer installing on existing structure with all required
materials arrangements as required as per IS specification.
Marked ISI & 3 Star rating
42.66.1
Copper wound
42.66.1.1 630 KVA
42.66.1.2 750 KVA
42.66.1.3 1250 KVA
Each
Each
Each
403804
656083
688687
Each
Each
Each
Each
363434
479044
792148
880667
each
1064480
each
each103
1248293
1658027
SOR ELECTRICAL 2014/CHAPTER-42
Page 103 of 114
42.67
42.68
42.69
42.70
42.71
42.71.1
42.71.2
42.71.3
42.71.4
42.71.5
42.72
42.73
42.74
Shifiting, erection, & commissioning of of 100/ 200 / 315 /
500 KVA (11/0.433 KV) distribution transformer on existing
structure including Bi-metallic clamp, ACSR/AAAC
Conductor i/c colour code sleeve, for connection from H.T.
Line to transformer as required as per specification.
each
Supplying and fixing Limit switch with accessories &
arrangement on existing HT/LT structure / poles AB switch
handle for inter locking between distribution panel main
incoming LT switch gear/ system as required to complete
the job.
each
Supply & fixing fencing of chain link mesh 100 x 100 mm,
12 SWG GI wire for for D.P. structure electric sub-station
including single post of angle iron size 50x50x5mm, 2.5 mt
long should be provided up to 2.00 mt. apart or as required
.The panel frame with required angle iron/ flat iron members
/cross members including mesh welded in frame panel,
shall be erected between the post. The angle iron post shall
be erected in cement concrete 1:2:4 ( 20 mm graded metal )
foundation, including excavation of pit and refilling the same
. The fencing shall be provided with one entrance gate
including locking arrangement as required as per
specification. The height of fencing shall be 2 mt. above
ground level. Fencing shall be painted with required shade.
Sq.Mt
Supply & fixing fencing of chain link mesh 100 x 100 mm,
12 SWG GI wire for electric sub-station switch yard
including single post of angle iron size 50x50x5mm, 2.5 mt
long should be provided up to 2.00 mt. apart or as required
with required angle iron/ flat iron members /cross members
for frame between the post & welded mesh including
cement concrete, excavation of pit and refilling the same .
The fencing shall be provided with one entrance gate
including locking arrangement as required as per
specification. The height of fencing shall be 2 mt. above
ground level. Fencing shall be painted with required shade.
Sq.Mt
Supplying & fixing of Fire Extinguisher/Refills as per IS
specification
ABC type duly refilled 6 Kg & ready to use
each
ABC type duly refilled 4 Kg &ready to use
each
ABC type -Refill only- 6Kg
each
ABC type -Refill only- 4Kg
each
4 buckets set with sand, self supported M.S.stand i/c shed
duly painted with red colour as per IS.
each
Supply of Rubber mat 2 x 1.0Mtr, 1100V Tested
each104
Supply of Hand Gloves 11KV Tested
pair
Supply of Hand Gloves 33KV Tested
pair
8191
1778
1110
773
3616
3277
1356
1017
4407
1582
622
938
SOR ELECTRICAL 2014/CHAPTER-42
Page 104 of 114
42.75
42.76
42.77
42.78
42.79
42.80
42.81
42.82
42.83
42.83.1
42.83.2
42.83.3
42.84
Supply of Fiber Discharge Rod I/C Connection copper Lead
Tested
Supply of Fiber D.O Operating Rod for 11 / 33KV Tested
Supply of First Aid Box complete with medicine & bandage
as per specification.
Supply of shock instruction chart duly framed with glass, as
reqd.
Supply and fixing transformer breather with silica gel
suitable for 100 -500 KVA as reqd.
Supply and filling of new transformer oil of desired break
down value for topping as reqd.
Filtration of transformer oil for 33/0.4 K.V., 11/0.4 K.V. 3
Phase 50 Cycle oil immersed, naturally cooled, distribution
transformer up to desired break down value.
each
each
set
565
each
339
each
300
Ltr.
140
Ltr.
15
Designing and construction of Pedestal (Plinth) for
transformer of desired size including excavation in hard
rock/soft rock, base concrete 1:4:8, 20mm thick and
pedestal of RCC 1:2:4 including required tar steel
reinforcement for required height as per IE Rules from base
concrete including shuttering and finishing with 10mm thick
plaster in cement mortor 1:3 curing & white washing etc.
complete as per specifications.
Cu. Mt.
Collection and spreading of metal dust, Murom and 40mm
graded hard metal in sub-station yard or as required as
mentioned below (i) Metal Dust
Cu. Mt.
(ii) Murom
Cu. Mt.
(iii) Metal 40 mm
Cu. Mt.
Supplying & drawing / laying of PVC insulated XLPE Aerial
bunch power cable conductor H2/H4 grade Aluminium
Solid/stranded confirming to IS-7098 Part-ll, Alu. Alloy
messenger of approved make in Air with necessary material
as per specification of required size as mentioned below –
42.84.1 11KV grade Arial Bunch Cable :42.84.1.1 3 x50 + 1 x 70 sq.mm.
42.84.1.2 3 x70 + 1 x 70 sq.mm.
42.84.1.3 3 x95 + 1 x 80 sq.mm.
42.84.1.4 3 x150 + 1 x 120 sq.mm.
42.84.2 33KV grade Arial Bunch Cable :-105
42.84.2.1 3 X 50 sq.mm.
42.84.2.2 3 X 95 sq.mm.
42.84.2.3 3 X 150 sq.mm.
2995
2656
8328
860
602
1087
P.Mt.
P.Mt.
P.Mt.
P.Mt.
911
1056
1233
1600
P.Mt.
P.Mt.
P.Mt.
1579
2002
2459
SOR ELECTRICAL 2014/CHAPTER-42
Page 105 of 114
42.85
42.85.1
42.85.1.1
42.85.1.2
42.85.2
42.85.2.1
42.85.2.2
42.85.2.3
42.85.2.4
42.85.2.5
42.85.2.6
42.85.2.7
42.86
42.87
42.88
42.88.1
42.88.2
42.89
Supplying & drawing / laying of PVC insulated XLPE Aerial
bunch power cable conductor H2/H4 grade Aluminium
Solid/stranded confirming to IS-14255- 1995, Alu. Alloy
insulated messenger 1100 volts grade cable of approved
make in Air with necessary material as per specification of
required size as mentioned below –
(i) Single Core cable( Insulated neutral messenger)
(a) 2x25 Sq.mm, 1x16( Insulated neutral messenger)
(b) 2x35 Sq.mm, 1x16( Insulated neutral messenger)
(ii) Single Core cable( Insulated neutral messenger)
(a) 3x25 Sq.mm, 1x16(St.Light), 1x35( Insulated neutral
messenger)
(b) 3x35 Sq.mm, 1x16(St.Light), 1x35( Insulated neutral
messenger)
(c) 3x50 Sq.mm, 1x16(St.Light), 1x35( Insulated neutral
messenger)
(d) 3x70 Sq.mm, 1x16(St.Light), 1x35( Insulated neutral
messenger)
(e) 3x95 Sq.mm, 1x16(St.Light), 1x50( Insulated neutral
messenger)
(f) 3x120 Sq.mm, 1x16(St.Light), 1x70( Insulated neutral
messenger)
(g) 3x150 Sq.mm, 1x35(St.Light), 1x95( Insulated neutral
messenger)
Supplying & fixing of Aerial bunch cable accessories
suspension clamps i/c required attachment for single core
cable of approved make on pole with clamp, necessary
material as per specification for required size.
P.Mt.
P.Mt.
153
181
P.Mt.
208
P.Mt.
211
P.Mt.
288
P.Mt.
390
P.Mt.
584
P.Mt.
703
P.Mt.
891
Each
343
Each
Supplying & fixing of waterproof Insulation Piercing
connector for Aerial bunch cable i/c required attachment for
single core cable of approved make in Air with necessary
material as per specification of required size as mentioned
below –
Main: 16-95sq.mm, Tap: 1.5-50sq.mm
Each
Main: 50-150sq.mm, Tap: 6-50sq.mm
Each
Supplying & fixing of Spring loaded bus bar screw less
connector with enclosure of approved make including
required clamps, nut, bolt, connection, testing as per
specification to complete the job. 106
371
Supplying & fixing of Aerial bunch cable accessories
Tension clamps(Dead end) i/c required attachment for
single core cable of approved make in Air with clamp,
necessary material as per specification for required size.
123
153
SOR ELECTRICAL 2014/CHAPTER-42
Page 106 of 114
42.89.1
42.89.1.1
42.89.1.2
42.89.1.3
42.89.1.4
42.89.1.5
42.89.1.6
42.89.2
42.89.2.1
42.89.2.2
42.89.2.3
42.89.2.4
42.89.2.5
42.90
Single Phase
1Ph, 1In+2Out
1Ph, 1In+3Out
1Ph, 1In+4Out
1Ph, 1In+5Out
1Ph, 1In+7Out
1Ph, 1In+8Out
Three Phase
3Ph, 1In+2Out
3Ph, 1In+4Out
3Ph, 1In+6Out
3Ph, 1In+7Out
3Ph, 1In+8Out
Providing and erecting 12mt High Mast Lighting system
suitable to install 6 No. 2 x 400 w M.H / S.V flood light fitting
and control gear with integral Power tool, weight 340 kg.
comprising of 1 section of hot dipped galvanized materials
as per BSEN ISO 1461 thickness 3 mm, dia 100mm &
360mm for top and bottom respectively, stress fitting
arrangement on site with 350mm overlap dynamic loading
to withstand max wind pressure as per -IS 875 part III,
parameters for structural & foundation design must be taken
from Wind Tunnel test. Lightning protection of GI single
spike 800mm at top and at base inside compartment with
double internal lock with adequate size of MCB erected on
PVC board complete with base plate of 25mm thick 520mm
dia. and foundation bolts having 4 nos. bolts of 24mm dia,
750mm long (EN8 grade), Anchor plate 445 PCD, including
accessories viz.(1) Lantern carriage of 50 NB ERW class-B,
MS pipe covered with PVC sleeve suitable to carry 250kg.
load and upto 6 fittings symmetrically.(2) Trailing Copper
cable 5x2.5 sq.mm, EPR insulated PCP 107
Sheathed (3) Double Drum / 350Kg Winch having gear
53:1, oil bath (SAE90/140) arrangement. (4) 2 nos.
Stainless steel wire ropes 5mm dia (7/19) breaking load
capacity 1450 kg.x 2, (5) Integral power tool 3-phase, 0.75
HP 2m/min single speed. (6) Feeder pillar fabricated out of
14 SWG CRCA sheet and comprise of incoming MCB 32 A
TPN switch, HRC fuses, single dial timer, suitable size of
contactors for lighting and power tool, 2 nos. outgoing,
reversing switch for motor. (7) Foundation drawing, test
certificate and guarantee certificate shall be provided by
manufacturer. (Without fixture and lamp)
Each
Each
Each
Each
Each
Each
2144
2204
3190
3365
3541
3668
Each
Each
Each
Each
Each
5194
6352
8334
8566
8797
each
332757
SOR ELECTRICAL 2014/CHAPTER-42
Page 107 of 114
42.91
Providing and erecting 16mt High Mast Lighting sytem
suitable to install upto 8 No. 2 x 250/ 400 w M.H / S.V flood
light and control gear with integral Power tool, weight 450
kg. comprising of 2 sections of hot dipped galvanized
materials as per BSEN ISO 1461 thickness 3 mm & 4 mm,
dia 150mm & 360mm for top and bottom respectively,
stress fitting arrangement on site with 500mm overlap
dynamic loading to withstand max wind pressure as per -IS
875 part III, parameters for structural & foundation design
must be taken from Wind Tunnel test. Lightning protection
of GI single spike 1200mm at top and at base inside
compartment having double internal lock with adequate size
of MCB erected on PVC board complete with base plate of
25mm thick 520mm dia. and foundation bolts having 6 nos.
bolts of 24mm dia 750 mm long (EN.8 grade) Anchor plate
445 PCD, including accessories viz. (1) Lantern carriage of
50 NB ERW class-B, MS pipe covered with PVC sleeve
suitable to carry 500kg. load and upto 8 fittings
symmetrically.(2) Trailing Copper cable 5x2.5 sq.mm, PVC
insulated PVC Sheathed (3) Double Drum 350Kg Winch
having gear 53:1, oil bath (SAE90/140) arrangement (4) 2
nos. Stainless steel wire ropes 5 mm dia (7/19) breaking
load capacity 1450 kg x 2, (5) Integral power tool 3-phase,
0.75HP 2m/min single speed .torque limiter up to 500 kg
adjustable (6) Single LED 300 Nos. aviation light (7)
Feeder pillar fabricated out of 14 SWG CRCA sheet and
comprise of incoming MCB 32 A TPN switch, HRC fuses,
single dial timer, suitable size of contactors for lighting and
power tool, 2 nos.outgoing, reversing switch for motor. (7)
Foundation drawing, test certificate and gurantee certificate
shall be provided by manufacturer. (Without fixture and
lamp)
each108
447501
SOR ELECTRICAL 2014/CHAPTER-42
Page 108 of 114
42.92
42.93
42.93.1
Providing and erecting 20mt High Mast Lighting system
suitable to install upto 10 No. 2 x 250/ 400 w M.H / S.V flood
light and control gear with integral Power tool, weight 450
kg. comprising of 2 sections of hot dipped galvanized
materials as per BSEN ISO 1461 thickness 3 mm & 4 mm,
dia 150mm & 410mm for top and bottom respectively,
stress fitting arrangement on site with 500mm overlap
dynamic loading to withstand max wind pressure as per -IS
875 part III, parameters for structural & foundation design
must be taken from Wind Tunnel test. Lightning protection
of GI single spike 1200mm at top and at base inside
compartment having double thickness 3 mm & 4 mm, dia
150mm & 410mm for top and bottom respectively, stress
fitting arrangement on site with 500mm overlap dynamic
loading to withstand max wind pressure as per -IS 875 part
III, parameters for structural & foundation design must be
taken from Wind Tunnel test. Lightning protection of GI
single spike 1200mm at top and at base inside
compartment having double internal lock with adequate size
of MCB erected on PVC board complete with base plate of
25mm thick 570mm dia. and foundation bolts having 8 nos.
bolts of 30mm dia 850 mm long (EN.8 grade) Anchor plate
490 PCD, including accessories viz.(1) Lantern carriage of
50 NB ERW class-B ,MS pipe covered with PVC sleeve
suitable to carry 500kg. load and up to 10 fittings
symmetrically.(2) Trailing Copper cable 5x4.0 sq.mm, PVC
insulated PVC Sheathed (3) Double Drum 750Kg Winch
having gear 53:1, oil bath (SAE90/140) arrangement (4) 2
nos. Stainless steel wire ropes 6 mm dia (7/19) breaking
load capacity 2350 kg.x 2,(5) Integral power tool 3-phase,
1HP 2m/min single speed .torque limiter up to 500 kg
adjustable (6) 2 Nos. LED 300 Nos. aviation light (7)
Feeder pillar fabricated out of 14 SWG CRCA sheet and
comprise of incoming MCB 63 A TPN switch, HRC fuses,
single dial timer, suitable size of contactors for lighting and
power tool, 2 nos. outgoing, reversing switch for motor. (7)
Foundation drawing, test certificate and guarantee
certificate shall be provided by manufacturer. (Without
fixture and lamp)
each
Providing and erecting hot dipped galvanized octagonal
poles in single section made from 3mm thick sheet having
lockable weather proof flush door junction box complete
erected in an approved manner on provided foundation.
Suitable size & type of foundation bolts 4 nos. 'J' type (EN8
grade)
3 mtrs. Height 130 X 70mm A/F, 200x200x12mm base
plate, 4 nos X 16 x 450mm bolt
each109
516348
8125
SOR ELECTRICAL 2014/CHAPTER-42
Page 109 of 114
42.93.2
42.93.3
42.93.4
42.93.5
42.93.6
42.93.7
42.93.8
42.94
42.95
42.96
42.97
42.97.1
42.97.2
42.97.3
42.98
42.99
4 mtrs. Height 130 X 70mm A/F,
plate, 4 nos X 16 x 450mm bolt
200x200x12mm base
5 mtrs. Height 130 X 70mm A/F, 200x200x12mm base
plate, 4 nos X 16 x 450mm bolt
6 mtrs. Height 130 X 70mm A/F, 220x220x12mm base
plate, 4 nos. X 20 x 600mm bolt
7 mtrs. Height, 130 X 70mm A/F, 220x220x12mm base
plate, 4 nos. X 20 x 700mm bolt
8 mtrs. Height, 135 X 70mm A/F, 225x225x16mm base
plate, 4 nos. X 20 x 750mm bolt
9 mtrs. Height, 155 X 70mm A/F, 260x260x16mm base
plate, 4 nos. X 24 x 750mm bolt
10 mtrs. Height, 175 X 70mm A/F, 275x275x16mm base
plate, 4 nos. X 24 x 750mm bolt
Providing and fixing of sword canopy type single arm GI
bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole
Providing and fixing of sword canopy type double arm GI
bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole
Providing and fixing of ring carriage dia. not less than
600mm made of 50mm dia. GI pipe Light 'A' class for 70mm
A/F top octagonal pole with required clamps, nut, bolt etc as
required.
Providing and erecting black painted galvanized decorative
designer poles in different section, top 60mm dia., bottom
140mm dia. with gold colour painted ornamental cast
aluminium ring having lockable weather proof flush door
junction box in bottom section, base plate dia. 290mm
having 4 holes of 22mm dia. complete erected in an
approved manner on existing foundation. Suitable size &
type of foundation bolts 4 nos. X 16mm X 450mm 'J' type
(EN8 grade)
3 Mtr. Height
4 Mtr. Height
5 Mtr. Height
Designing & casting of Open raft shallow footing foundation
with M-20 cement concrete suitable for 12mtrs. High Mast
considering the safe soil bearing capacity at site as 10
T/sqm at 2mtrs. Depth including excavation, foundation nut
bolts in an approved manner.
Designing & casting of Open raft shallow footing foundation
with M-20 cement concrete suitable for 16mtrs. High Mast
considering the safe soil bearing capacity at site as 10
T/sqm at 2mtrs. Depth including excavation, foundation nut
bolts in an approved manner.
each
10112
each
12098
each
14797
each
16783
each
18988
each
24908
each
29403
each
3478
each
5645
each
2583
each
each
each
31323
34260
43069
each
45000
each110
60000
SOR ELECTRICAL 2014/CHAPTER-42
Page 110 of 114
42.100
42.101
Designing & casting of Open raft shallow footing foundation
with M-20 cement concrete suitable for 20mtrs. High Mast
considering the safe soil bearing capacity at site as 10
T/sqm at 2mtrs. Depth including excavation, foundation nut
bolts in an approved manner.
each
Designing & casting with M-20 reinforcement cement
concrete foundation suitable for Octagonal poles
considering the safe soil bearing capacity at site as 10
T/sqm at 2 mtrs. Depth including excavation, foundation nut P.
bolts in an approved manner.
Cu.M111
70000
14435
SOR ELECTRICAL 2014/CHAPTER-42
Page 111 of 114
LIST OF APPROVED ELECTRICAL MATERIAL / ACCESSORIES TO BE USED
GROUP 'A'
S.No.
ITEM
MAKE
1
PVC insulated copper conductor
insulated & Sheathed flexible
conductor FR ISI marked
2
PVC insulated Telephone / Cat 6 / TV cable
ISI marked FR
3
PVC conduit pipe ISI marked & accessories
4
5
, PVC
copper
PVC casing-N-capping
ISI marked
&
accessories
Steel conduit pipe ISI marked & accessories
8
9
Non- Modular type flush type switch, socket ,
ceiling rose, lamp holder , call bell,
Modular type flush type switch, socket , ceiling
rose, lamp holder, call bell,
Phenolic laminated sheet
MCB, Isolator, RCCB, RCBO, MCB-DB
10
XLPE insulated cable, Air Bunch Cable(ABC),
11
GLS, CFL, SV,MH, Lamp
12
LED lamp
13
Luminaries SV, MH, CFL, FTL-T5
14
Luminaries LED,
15
GI pipe ISI Mark
16
ACSR , AAAC conductor
17
Electronic ballast
18
Electric Ceiling fans
19
Wall mounting fan, Cabin fan, Exhaust fan,
20
21
22
23
Steel tubular pole
Octagonal pole
High mast
Ornmental pole
24
Cable gland
6
7
REMARK
Havell's , Finolex Anchor, standard,
polycab, HPL, RR Kabel,
Havell's , Finolex, Anchor, standard,
polycab, RR Kabel, Legrand
BEC , Modi, Shrinath, Kent,
Precision, Polycab,
Presto plast , Press fit, Shrinath,
Modi, BEC, Precision,
BEC , AKG, Modi,
Anchor, SSK, HPL, CPL
Legrand, Anchor Roma, C&S, L&T,
Wipro North West, HPL,
Hylum, Anchor
Legrand, L&T, C&S,
Finolex, Polycab, Havell's , RAVIN
Cables, Paramount, AEI, V-Mark,
Gupta Power, Daimond Power, RR
Cable,
Philips, Bajaj, Crompton, osram,
GEC,
Philips, Bajaj, Crompton, Wipro,
osram, SYSKA
Philips, Bajaj, Crompton, Wipro,
Philips, Bajaj, Crompton, Wipro,
SYSKA, Panasonic
TATA, Swastik TT, Jindal, Surya
Grandlay , Bhopal Wires, Gupta
Power, Daimond Power,
Philips, Bajaj, Crompton, Wipro,
Cromton , Bajaj, Usha, Orient,
Havell's
Almonard, Crompton , Bajaj, Usha,
Orient,
As per IS 2713-1980
Bajaj, Philips, Valmont
Bajaj, Philips, Valmont
Bajaj, Dwarka, Homedec
Comet , Calter(National), Cosmos,
Jainson, ascon, sigma112
SOR ELECTRICAL 2014
Page 112 of 114
25
26
27
28
29
30
Cable lug
SFU, ACB, Change Over Switch(On-load),
MCCB,
SFU(Rewireable), Change Over Switch (Off
Load), ATS, Busbar,
Fan / Luminaries Capacitor,
Power Capacitor
Ammeter, volt meter,Voltmeter, Selector
switch/ CT's,
31
Lightening Arrestor , AB Switch. DO fuse
32
Cable jointing kit
33
Distribution Transformer
34
Insulator Porcelain
35
Insulator Polymer
36
DO fuse
SUBMERSIBLE / OPENWELL /
CENTRIFUGAL MOTOR PUMP SET
STARTER
37
38
39
40
SUBMERSIBLE CABLE
41
STAINLESS STEEL ROPE
HDPE PIPE, UPVC, CPVC, DWC pipe &
accessories
42
43
ESE LIGHTNING CONDUCTOR
BUS TRUNKING SANDWICH
Comet , Calter(National), Cosmos,
Jainson, ascon
Legrand ,L&T, Crompton, C&S,
HPL, Standard, Havell's , SHI, C&S,
Crompton
Asian, Uni-star, Bajaj, Epcos,
L&T, Neptune,
AE, Neptune, L&T, ELEMEASURE,
Oblum, Elpro, Alstom, Jaipuria, GE,
Atlas, GK, MPMKVVCL approved,
Raychem, Mahindra, Birla, M-seal,
Denson, 3M,
Tesla, Star Delta, Kirlosker, Alstom,
Voltmap, Crompton
Atals, Jaipuria, JSI, modern insulaor,
MPMKVVCL approved,
Stock,
Rastriya,
MPMKVVCL
approved,
Atals, Jaipuria, GK,
KIRLOSKAR, CROMPTON, VGUARD, TEXMO, CRI, KSB
KIRLOSKAR, CROMPTON, VGUARD, TEXMO, CRI, L&T,
SIEMENS, C&S
POLYCAB, FINOLEX, HAVELL'S,
RAVIN CABLES, L&T,
USHA MARTIN or EQUIVALENT
KASTA, HASTI, KML Classic
(KISAN), VIP PIPES, Supreme,
Finolex
ABB, Siemens, Indolec, Schenider
Legrand, Siemens, L&T, C&S113
(Er. Vijay Singh Verma)
Project Director
MP P.W.D. (P.I.U) Bhopal114
SOR ELECTRICAL 2014
Page 113 of 114
Annexure-1
Guide Line For Rewiring
3
4
5
2
2
3
4
2
4
5
6
4
5
6
7
CFL 18 Watt
0
0
2
2
CFL 5 Watt
1
1
2
2
Call Bell Point
In Club housing including blocks, there shall be one pipe earthing. Hence
separate earthing will not be provided for each quarter.
Service line shall be taken in actually required length separately
Additional electrical point can be taken with the permission of Executive
Engineer
Extra required Fans, Fixtures etc can be taken with the permission of Executive
Engineer115
6
7
8
9
Socket on Same
Board
2
1
2
2
2
Separate Socket
Point
3
4
5
6
Power Point
2
3
4
5
Street light Point
I- Type
H- Type
G- Type
F- Type
Exhaust Fan Point
Tube light Point
1
2
3
4
Holder Point
Type of
Qtr
Bulk head Point
S.No.
Ceiling Fan Point
1
The following provisions are being made for specified quarter
Details of Fans / Fixtures etc
1
1
1
1
3
3
3
4
4
6
7
7
SOR ELECTRICAL 2014
Page 114 of 114
Download