ATIS-0403104-0002 Section 10.4 Telecommunications Additional Code Lists EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 10.4 Telecommunications Additional Code Lists This section contains data elements maintained by the OBF EDI Guideline Consistency Subcommittee (EGCS) or an external source. For the maintained code lists of DE150, DE560, DE751, DE822, DE1000, DE1271 and DE1301 the complete list of code values are shown. For DE26, DE66, DE100, DE116 and DE156 external sources, a contact is given from which the user can obtain a current list. DE128, DE235 and DE1104 contain code lists that are subsets of ASC X12 maintained code lists for which either EGCS maintains associated phrase codes and values, or, associated values are found in an external code list. All EGCS maintained codes listed in Section 10.4 can be used immediately, regardless of the X12 Version/Release listed in the header of this document. The Version/Release number is only used to identify the attributes that the ASC X12 Data Elements are related to. NOTE 1: Common Language is a registered trademark and CLEI, CLLI, CLCI, and CLFI are trademarks of Telcordia Technologies NOTE 2: Starting in January 2004, the 10.4 section will reflect all references and language to the new ATIS structure, which eliminates the Telecommunications Industry Forum (TCIF) entity and moves the EGCS unit within the Ordering and Billing Forum (OBF) functional group of ATIS. of Names of Countries. The code may be a threecharacter alphabetic or three-digit number. The two leftmost characters of the alphabetic code identify the currency authority to which the code is assigned (using the two character alphabetic code from ISO 3166, if applicable). The rightmost character is a mnemonic derived from the name of the major currency unit or fund. For currencies not associated with a single geographic entity, a specially-allocated two-character alphabetic code, in the range XA to XZ identifies the currency authority. The rightmost character is derived from the name of the geographic area concerned, and is mnemonic to the extent possible. The numeric codes are identical to those assigned to the geographic entities listed in ISO 3166. The range 950-998 is reserved for identification of funds and currencies not associated with a single entity listed in ISO 3166. 26 Country Code TYPE=ID MIN=2 MAX=3 Code identifying the country. SOURCE: (X12 Code Source 5) Codes for Representation of Names of Countries, ISO 3166-(Latest Release) Codes for Representation of Currencies and Funds, ISO 4217-(Latest Release) AVAILABLE FROM: American National Standards Institute, Inc. 25 W. 43rd St., 4th Floor New York, NY 10036 INTERNET: http://www.ansi.org ABSTRACT: Part 1 (Country Codes) of the ISO 3166 international standard establishes codes that represent the current names of countries, dependencies, and other areas of special geopolitical interest, on the basis of lists of country names obtained from the United Nations. Part 2 (Country subdivision codes) establishes a code that represents the names of principal administrative divisions, or similar areas, of the countries included in Part 1. Part 3 (Codes for formerly used names of countries) establishes a code that represents non-current country names, i.e., the country names deleted from ISO 3166 since its first publication in 1974. Most currencies are those of the geopolitical entities that are listed in ISO 3166, Part 1, Codes for the Representation 66 Identification Code Qualifier TYPE=ID MIN=1 MAX=2 Code designating the system/method of code structure used for Identification Code (DE 67). CODE 41 DESCRIPTION of DE66 Code Telecommunications Carrier Identification Codes (CIC Codes) SOURCE: (X12 Code Source 719) NANPA – North American Numbering Plan Administration 2 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE66 Code CODE DESCRIPTION of DE66 Code telephone billing arrangements. AVAILABLE FROM: NANPA – North American Numbering Plan Administration 46000 Center Oak Plaza, Building 10 Sterling, VA. 20166 SOURCE: OCN – Operating Company Number INTERNET: http://www.nanpa.com AVAILABLE FROM: NECA– National Exchange Carrier Association 80 South Jefferson Road Whippany, NJ 07981 ABSTRACT: Provides and maintains a list of telecommunications carrier identification codes which are used in the ordering and billing of telecommunications services. INTERNET: www.neca.com 42 Telecommunications Pseudo Carrier Identification Code ABSTRACT: Provides and maintains a list of Operating Company Number (OCN) codes which are used in the routing and settlement of messages and charges between telecommunications carriers. A code similar to the standard Carrier Identification Code which is used to identify the local exchange service providers. See SOURCE information below. SOURCE: COMMON LANGUAGE EC Codes Telcordia Technologies practice BR 751100-112 NOTE: The specific code source used for any given application may be subject to trading agreement. TelecommunicationsEDI Guidelines for TELEPHONE BILLING applications use Pseudo-CIC Codes found in Appendix B of this document. AVAILABLE FROM: Telcordia Technologies COMMON LANGUAGE Products Customer Support Center 45 Knightsbridge Road Piscataway, NJ 08854 TelecommunicationsEDI Guidelines for SERVICE ORDERING applications use OCN and Common Language EC codes. INTERNET: www.commonlanguage.com ABSTRACT: COMMON LANGUAGE Products provide the ability to communicate effectively within your company and with customers, suppliers, and other telecommunications providers. COMMON LANGUAGE products facilitate network and service management, increase operational efficiency, provide interoperability and increase customer satisfaction. They include Network Identification, Equipment Identification and Service Information. SOURCE: Pseudo-CIC Codes TelecommunicationsEDI Guidelines, Section 10.4, Appendix B AVAILABLE FROM: Alliance for Telecommunications Industry Solutions 1200 G Street, N. W., Suite 500 Washington, DC 20005 (202) 628-6380 91 Assigned by Seller or Seller's Agent INTERNET: http://www.atis.org A code similar to the standard Carrier Identification Code which is used to identify the service provider. ABSTRACT: Provides and maintains a list of pseudo-CIC codes for use in 3 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE66 Code CODE management, increase operational efficiency, provide interoperability and increase customer satisfaction. They include Network Identification, Equipment Identification and Service Information. NOTE: The specific code source used for any given application may be subject to trading agreement. Telecommunications EDI Guidelines for TELEPHONE BILLING applications use this qualifier when a CIC or pseudo CIC (Section 10.4 Appendix B) is not applicable. DE 67 may be an OCN code. SOURCE: OCN – Operating Company Number 100 Currency Code TYPE=ID MIN=3 MAX=3 Code (Standard ISO) for country in whose currency the charges are specified. SOURCE: (X12 Code Source 5) Codes for Representation of Names of Countries, ISO 3166-(Latest Release) Codes for Representation of Currencies and Funds, ISO 4217-(Latest Release) AVAILABLE FROM: NECA– National Exchange Carrier Association 80 South Jefferson Road Whippany, NJ 07981 AVAILABLE FROM: American National Standards Institute, Inc. 25 W. 43rd St., 4th Floor New York, NY 10036 INTERNET: www.necaservices.com ABSTRACT: Provides and maintains a list of Operating Company Number (OCN) codes which are used in the routing and settlement of messages and charges between telecommunications carriers. BE DESCRIPTION of DE66 Code INTERNET: http://www.ansi.org ABSTRACT: Part 1 (Country Codes) of the ISO 3166 international standard establishes codes that represent the current names of countries, dependencies, and other areas of special geopolitical interest, on the basis of lists of country names obtained from the United Nations. Part 2 (Country subdivision codes) establishes a code that represents the names of principal administrative divisions, or similar areas, of the countries included in Part 1. Part 3 (Codes for formerly used names of countries) establishes a code that represents non-current country names, i.e., the country names deleted from ISO 3166 since its first publication in 1974. Most currencies are those of the geopolitical entities that are listed in ISO 3166, Part 1, Codes for the Representation of Names of Countries. The code may be a threecharacter alphabetic or three-digit number. The two leftmost characters of the alphabetic code identify the currency authority to which the code is assigned (using the two character alphabetic code from ISO 3166, if applicable). The rightmost character is a mnemonic derived from the name of the major currency unit or fund. For currencies not associated with a single geographic entity, a specially-allocated two-character alphabetic code, in the range XA to XZ identifies the currency Common Language Location Identification (CLLI) The standard address location code for a specific equipment location as used in the telephone industry SOURCE: (X12 Code Source 138) COMMON LANGUAGE Products AVAILABLE FROM: Telcordia Technologies COMMON LANGUAGE Products Customer Support Center 45 Knightsbridge Road Piscataway, NJ 08854 INTERNET: www.commonlanguage.com ABSTRACT: COMMON LANGUAGE Products provide the ability to communicate effectively within your company and with customers, suppliers, and other telecommunications providers. COMMON LANGUAGE products facilitate network and service 4 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 authority. The rightmost character is derived from the name of the geographic area concerned, and is mnemonic to the extent possible. The numeric codes are identical to those assigned to the geographic entities listed in ISO 3166. The range 950-998 is reserved for identification of funds and currencies not associated with a single entity listed in ISO 3166. 128 Reference Identification Qualifier TYPE=ID MIN=2 MAX=3 Code qualifying the Reference Identification. Codes listed here are those for which: EGCS maintains a list of associated "phrase codes" for use in REF02, REF03, N902 or N903 which are listed with the qualifier; EGCS's use of the qualifier requires the use of values maintained by an external source. 116 Postal Code TYPE=ID MIN=3 MAX=15 Code defining international postal zone code excluding punctuation and blanks (zip code for United States). CODE 11 DESCRIPTION of DE128 Code Account Number Valid Entries for DE352 (REF03) AAN Associated Account Number AN Account Number ATN Account Telephone Number EAN Existing Account Number EATN Existing Account Telephone Number LEAN Line EAN LEATN Line EATN NAN New Account Number NATN New Account Telephone Number SMDRAC SMDR Account code SOURCE: (X12 Code Source 51) National ZIP Code and Post Office Directory, Publication 65 The USPS Domestic Mail Manual AVAILABLE FROM: U. S. Postal Service Washington, DC 20260 New Orders Superintendent of Documents P.O. Box 371954 Pittsburgh, PA 15250-7954 12 ABSTRACT: The ZIP Code is a geographic identifier of areas within the United States and its territories for purposes of expediting mail distribution by the U. S. Postal Service. It is five or nine numeric digits. The ZIP Code structure divides the US into ten large groups of states. The leftmost digits identifies one of these groups. The next two digits identify a smaller geographic area within the large group. The two rightmost digits identify a local delivery area. In the nine-digit ZIP Code, the four digits that follow the hyphen further subdivide the delivery area. The two leftmost digits identify a sector which may consist of several large buildings, blocks, or group of streets. The rightmost digits divide the sector into segments such as a street, a block, a floor of a building, or a cluster of mailboxes. Billing Account Number Valid Entries for DE352 (REF03) BAN Billing Account Number BAN1 Billing Account Number 1 BAN2 Billing Account Number 2 DBAN1 DSR Billing Account Number 1 DBAN2 DSR Billing Account Number 2 VAN Vertical Account Number 1Q Error Identification Code (Error remarks) Valid entries for DE127 (N902) ERR Error Notice Processing Codes and or Text messages describing the error conditions detected in a validation process. Valid entries for DE369 (N903) ERRCOD Error Code E Identifies the code associated with the error message. LECODE Listing Error Code Identifies an error condition discovered while processing a The USPS Domestic Mail Manual includes information on the use of the 11 digit ZIP Code. 5 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE128 Code CODE directory service request. PRESPC Provider Response Code Identifies a provider specific code on the response transaction that represents what occurred on the associated inquiry transaction. RESPC Response Code An OBF maintained code which identifies a code on the response transaction that represents what occurred on the associated inquiry transaction. 1V SOURCE: LATA Directory AVAILABLE FROM: Center for Communications Management Information 11300 Rockville Pike, Suite 1100 Rockville, MD 20852-3030 1-888-ASK-CCMI (1-888-275-2264) INTERNET: www.ccmi.com ABSTRACT: CCMI's LATA Directory shows area codes and exchange numbers within each LATA across the U.S., including LATAs within states, numeric list of LATAs, alphabetical list of LATA names, rate center directory by LATA, and LATAs by NPA and NXX. Updated twice a year. Related Vendor Order Number Valid Entries for DE352 (REF03) DLRORD Directory Listing Related Order Number DARORD Directory Assistance Related Order Number RORD Related Order Number 2I 4N Special Payment Reference Number The following notes apply to the use of this code for Service Ordering: For a list of Valid Values used with this code for DE127 (REF02) see the current issue of the OBF Local Service Ordering Guidelines (LSOG). Tracking Number The following notes apply to the use of this code for Service Ordering: Valid Entries for DE352 (REF03): DSRNO Directory Service Request Number LSRNO Local Service Request Number VSRNO Vertical Service Request Number 4L DESCRIPTION of DE128 Code Valid Entries for DE352 (REF03) BI1 Billing Account ID 1 BI2 Billing Account ID 2 DBI1 DSR Billing Account ID 1 DBI2 DSR Billing Account ID 2 Location-specific Services Reference Number 55 For OBF CABS BOS billing applications this qualifier is used to provide LATA code information. The LATA code is the common language code for EC Local Access Transport Areas in which service is being provided Sequence Number Identifies whether the transfer telephone numbers are primary or secondary. Also used to identify the Hunting sequence number (s). Valid Entries for DE352 (REF03) PRI Primary SEC Secondary Valid Entries for DE369 (N903) HTSEQ Hunt Sequence 82 Data Item Description (DID) Reference Valid entries for DE127 (N902) APPTINFO Appointment Information Identifies the access information, e.g., hours, 6 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE128 Code CODE for the appointment CODEDES Code Description Identifies the description of the information in the CODE field CR Cross Reference Text portion of a cross reference listing or tie back text, e.g., See Smith and Smit. DCGMU Design Cable Gauge Make-Up Identifies the loop makeup by cable gauge and length. DES Designation Professional designation phrase of a business listing. DISPNOTES Dispatch Notes Dispatch or log information associated with the service order. EMAT Email Listing Text Identifies the text that will appear on an Email address listing that is associated with a main listing. FAINFO File After Information HADDR Header Address Caption or SLU header address as it appears in the directory. INADDR Indent Level Address Address on the prior level indent. INTEXT Indent Level Text Text on the prior level indent. ITEXT Indent Text Text for caption subheads or caption/SLU indents along with address and telephone number e.g., Reservations. LISTADR Listed Address Combined elements from the request that provide the address as it will be listed in Directory and or Directory Assistance. LISTNM Listed Name Identifies the name contained in the listing. It DESCRIPTION of DE128 Code LISTTEXT LNFN LNLN LNPL LOI LTEXT LTXTY MSDAPT NICK OMSD contains the elements that were received in the LNLN, LNFN, DES, TL, TITLE1, TITLE2 and NICK fields on the directory service request. Listing Text Text that appears in a directory listing other than the name and address. Listed Name First First word for business listings or all of the first name or names and middle name or initials for residence listings. Listed Name Last First word for business listings or the complete last name for residence listings. Listed Name Placement Identifies the placement of the listing based on the LNLN field. Line of Information Descriptive or informative text that appears in the directory to assist the end user, e.g., call Between 9 and 5. Listing Text Text that appears in a directory listing other than the name and address. Listing Text Type Identifies the type of associated text that will appear in the directory listing to assist the end user. For a list of Valid Values used with this code in DE369 (N903) see the current issue of the OBF Local Service Ordering Guidelines (LSOG). Missed Appointment Information The reason the appointment was not met. Nickname A listed person's nickname. Omit from Second Directory 7 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE128 Code CODE Indicates the secondary directory or directories this listing is not to appear in. ORCD Order Response Code Detail Provides a description of the response code. PLA Place Listing As Special filing words that should be used instead of the listed name if the customer wishes to override the normal sequencing. PLINFO Prior Level Information SEQADDR Sequence Address Address text of an indent that a sequence override should follow. SEQADDR1 Sequence Address 1 Address text of an indent that a sequence override should follow. SEQTEXT Sequence Text Indent text that a sequence override should follow. SEQTEXT1 Sequence Text 1 Indent text that a sequence override should follow. SODETAIL Service Order Detail Used to return a copy of the service order in freeflowing text format. SOSTATDE- Service Order Status S Description TITLE1 Title of Address 1 A phrase used to address a listed person, e.g. Mr., Dr, etc. TITLE2 Title of Address 2 Additional phrases used to address a listed person, e.g. Mr., Dr, etc. TL Title or Lineage A phrase used to designate lineage of a listed person, e.g. Jr., Sr., III, etc. TNTC Telephone Number Text Centered Centered, special telephone text phrases, e.g., dialing instructions. DESCRIPTION of DE128 Code TNTL TNTR URLT WPP YPH YPHV 9K Telephone Number Text Left Left justified, special telephone text phrases, e.g., dialing instructions. Telephone Number Text Right Right justified, special telephone text phrases, e.g., dialing instructions. Internet Listing Text Identifies the text that will appear on an Internet address listing. White Pages Products Information about the White Page Products, Signature Listings, Personality Logo and Lines of Distinction, e.g., SS = signature script, SB = signature bold, etc. Yellow Pages Heading Alphanumeric code for heading under which a business is listed in the Yellow Pages directory. Yellow Page Heading Verbiage Text heading under which a business is listed in the Yellow pages directory. Valid Entries for DE369 (N903) LRC Listing Response Code Servicer Valid Entries for DE352 (REF03) SPIT Service Provider Indicator Type Identifies the type of entry in the SPN Service Provider Name field. For a list of Valid Values used with this code in DE127 (REF02) see the current issue of the OBF Local Service Ordering Guidelines (LSOG). CO Customer Order Number Order number provided by the customer that is used as the Purchase Order Number (PON). Valid Entries for DE352 (REF03) DRPON Directory Related PON RPON Related PON 8 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE H7 INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE128 Code CODE DESCRIPTION of DE128 Code Standard Clauses (Retained Remarks) Valid entries for DE127 (N902) AAI Additional Address Information ACC Access Instructions Remarks which define the instructions for obtaining access to a customer's premises for installation of a service or circuit. Codes of EU for End User and RPLPRI and RPLSEC will be used in N903 to indicate Resale Private Line primary and secondary. ALOC Additional Location Detail Identifies any necessary location information and indicates further definition of the physical point of termination at the location. Codes of RPLPRI and RPLSEC will be used in N903 to indicate primary and secondary. BLI Billing Instructions Provide unique billing instructions. DIR Additional Directory Instructions Provide additional instructions about the format or content of the directory listing. ENG Engineering Notes Information and specifications provided by the Customer's Engineer in configuring the equipment for a particular job. INS Installation Notes Information and requirements provided by the customer to assist in the Supplier's installers when installing the equipment. LIN Line Item Notes Information and specifications provided by the customer for line items. LOC Location Instructions Remarks which define a location used for a circuit or service. ORI Order Instructions Remarks to expand upon or clarify other data in the service request or other data in a directory request, identified by the type of form remarks listed in N903, e.g., LSR, EU, DSR, DL, DSCR, etc. ORR ORS ROU TCS IX These remarks may be included on an original service request or included on a supplemental service request to be appended to the remarks on the original request or included on a separate directory request. Replacement Order Instructions Remarks on a supplemental service request which replace the remarks included on the original request. Telecommunications Provider/Originated Order Instructions Remarks originated by a telecommunications provider during the processing of a service request and returned to the customer. Routing Instructions Instructions for the routing of data circuits or other services using designated telecommunications circuits. Transfer Calls Information Additional instructions about call transfers. Item Number Valid Entries for DE352 (REF03) API Attendant Position Indicator DELNUM Delivery Reference Number DIDNUM DID Reference Number DLNUM Directory Listing Reference Number DNUM Disconnect Number DREFNUM Directory Reference Number ERNUM Error Detail Reference Number HNUM Hunt Reference Number INQRESNBR Inquiry Response Number LEGNUM Multipoint leg number LNEX Line Reference Number Extension LNUM Line Reference Number LOCNUM Location Number PONLEREFN PON Listing UM Confirmation/Error Code Reference Number. REFNUM Reference Number 9 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE DESCRIPTION of DE128 Code RESID RNEX RNUM UNUM VCNUM LU INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE Response Identifier Reference Number Extension Reference Number UNI Number Virtual Connection Number Valid Entries for DE127 (REF02): Y Copy provided upon request. S Chart/date may be reviewed only at the supplier location. N No copy/data available. SU TD For OBF LSOG service ordering applications this qualifier is used to provide a reference number that identifies the loop between the central office and a serving terminal, for loop qualification, also known as a Taper Code. Valid Entries for DE352 (REF03): TC Taper Code Reason for Change For a list of Valid Values used with this code in DE127 (REF02) see the current issue of the OBF Local Service Ordering Guidelines (LSOG). V0 Version Letters or Notes (Non retained Remarks) For a list of related phrase codes, see code H7 X3 MZ Network Modifications Required OW A locally defined code that identifies the network modifications necessary to provide facilities to the service address. Service Order Number Valid Entries for DE352 (REF03) BULK- Bulk Package Version VER PONVER Purchase Order Version Identification Defect Code Valid Entries for DE127 (REF02): AA Automatic Assembly AF Automatic Fabrication AT Analytical Test CT Chemical Test EC Electrical Connecting FT Function Test IP Installation Process - Other MA Manual Assembly MP Marking or Packaging MT Mechanical Test OT Other types of defects/tests PT Physical Test WC Wiring and Cabling Valid Entries for DE352 (REF03) BOPI Bulk Order Package Identifier CS01 Conversion Order 1 CS02 Conversion Order 2 DAORD Directory Assistance Order Number DLORD Directory Listing Order Number LORD Loop Order Number ORD Order Number ORDL Line Level Order Number SON Service Order Number RE Special Processing Code Valid Entries for DE352 (REF03) CNTYPE Confirmation Type DCNR Directory Confirmation Type Returned DRTR DSR Response Type Requested RT Response Type RTR Response Type Requested Valid Entries for DE369 (N903) LRNUM Listing Response Number Location Number For OBF CABS BOS billing applications this qualifier is used to provide Access Customer Location information. This is a common language CLLI code of the terminal location of the access customer providing the service. L1 DESCRIPTION of DE128 Code 150 Special Charge Code TYPE=ID MIN=3 MAX=3 Code identifying type of special charge or allowance. Release Number 10 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE EGCS MAINTAINED CODE VALUES CODE DESCRIPTION of DE150 Code 120 230 275 295 586 AAJ ACD ACF ACH ACS AGR Banking Drafts Credit Discount Incentive Discount Special Processing Charge Adjustments Allegheny County, PA Delivery Charge Access Charge Federal Access Charges Access Charge State Amount Base for Gross Receipts Tax This code is used to display the amount of calls collected for Gross Receipts Tax. Adjustment for Maximum Charges Billing Absolute Minimum Charge Adjustment for Minimum Average Time Requirement Billing Adjustment for Minimum Charges Billing Base charge used to depict the base on which tax amounts are computed. Cancellation Charge Concession Credit Customer Owned Party Telephone Surcharge Connect Charge Commercial Radio Service Fee Deposit Disconnect Check Charge Disconnect Charge Digital Divide Fund Deaf and Disabled Surcharge Discount Dispute Exchange Access Credit E911 Administration Charge Expanded Local Calling Surcharge Equal Access Surcharge Emergency Service Franchise Fee Finance Charge Federal Transfer Surcharge Federal Universal Service Groupage Discount Gross Receipts Surcharge Holding Charge Invoice Adjustment Infrastructure Maintenance Credit Interest on security deposit License Fee Long Term Number Portability AMB AMC AMP ANB BAS CAA CCR CEF COC CRS DAB DCC DCS DDF DDS DSC DSP EAC EAD ECL EQA ESC FFA FFI FTC FUS GRD GRS HDG IIA IMC ISD LAE LNP LPA LPC LPP LSS MEM MGA MGC MMF MSG MUS NPF NPI NPS OFL OLC OLM ORC PAD PAH PAI PCC PCR PEN PMC PPO PPP PPU PSP QQD RAA RCS REE RFD ROW RRR SAF SAP SER SMF SMS SSO STC SUF DESCRIPTION of DE150 Code Surcharge Late Payment Charge Alternate Late payment charge LPC - Previous Segment Lifeline Surcharge Membership Fee(s) Message Rate Adjustment Message Charge Municipal Maintenance Charge Miscellaneous Charge Municipal Surcharge No PIC Federal Charge No PIC Intra No PIC State Charge Official Service A code used to identify charges that are for official company business. These amounts are not due or payable to the provider, e.g. the provider does not pay itself. Use of this code is to be negotiated in your trading partner agreement. Other Line Charge - Canadian Portion (See Note 3 in Appendix A) Other Line Charge - Mexican Portion (See Note 3 in Appendix A) Operator Credit Premium Charge Promotional Allowance Promotional Discount Poison Control Center Surcharge Performance Credit Penalty Prior Month Credit Per Order Charge Payphone Public Policy Surcharge Prepaid Usage Allowance Payphone Service Provider Surcharge Quantity Discount Rebate Reconnect charge Regulatory Fee Refund Rights of Way Use Fee Regulatory required refund Special Credit Service Assistance Program Surcharge Service Charge State Maintenance Charge State/Metropolitan Transit Authority Surcharge. Pole, Wood-service Charge State Surcharge Set Use Fee - Customer Charge 11 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE SUR SUS TCB TDC TPP TR1 TR2 TRL TRS TRT TXS UNC UPD UTL VAB WAT ZZZ INDUSTRY CONVENTIONS ASC X12 Version 004050 Provinces: DESCRIPTION of DE150 Code (See Note 3 in Appendix A) Surcharge State Universal Service Telegram Charge back Telecomm. Device for the Deaf Credit This credit is given to customers for hearing-impaired individuals, which use certain services and are allowed, credits. Transfer Payment Transferred Charges or Credit from Another Account or Invoice Transferred Charges or Credit to Another Account or Invoice Transfer Local Tax (See Note 3 in Appendix A) Transferred Charges Transfer State Tax (See Note 3 in Appendix A) Tax Surcharge Uncollectable Charge Code used to identify the amount that is charged to cover uncollectable bill amounts. Usage Plan Detail Charge Buried Facilities Surcharge Volume Discount Wide Area Telephone Service (WATS) Usage Credit Mutually Defined (See Note 1 in Appendix A) CODE AB BC MB NB NF NS NT ON PE PQ SK YT PROVINCE Alberta British Columbia Manitoba New Brunswick Newfoundland Nova Scotia North West Territories Ontario Prince Edward Island Quebec Saskatchewan Yukon 235 Product/Service ID Qualifier TYPE=ID MIN=2 MAX=2 Code identifying the type/source of the descriptive number used in Product/Service ID (234). EGCS MAINTAINED CODE VALUES CODE A6 156 State or Province Code TYPE=ID MIN=2 MAX=2 Code (Standard State/Province) as defined by appropriate government agency. DESCRIPTION of DE235 Code Document Identification Code To facilitate the identification of detail level data, the Document Identification Code of “A6” will be passed at the PO1 level to specifically identify what type of data the sender wants the receiver to process. Valid DE 234 Entries: CKT Circuit Detail Section CTXCB CENTREX Common Block CTXSD CENTREX Station Details DDA Directory Delivery Address DID Direct Inward Dialing DL Directory Listing DIR Local Response (LR) Directory DSC Disconnect DSCN Directory Service Completion Notice DSCR Directory Service Caption Request DSR Directory Service Request DSRED Directory Service Request Error Detail EU End User HNT Hunting, Resale and Unbundled Local Switching (Port) practices HNTR Local Response (LR) Hunt SOURCE: (X12 Code Source 22) National ZIP Code and Post Office Directory AVAILABLE FROM: US Postal Service National Information Data Center P.O. Box 2977 Washington, DC 20013 ABSTRACT: Provides names, abbreviations, and codes for the 50 states, the District of Columbia, and the outlying areas of the US. The entities listed are considered to be the first order divisions of the US Microfiche available from NTIS (same as address above). The Canadian Post Office lists the following as “official” codes for Canadian 12 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE235 Code CODE Group RPLPRI Resale Private Line (RPL) Primary (PRI) RPLR Resale Private Line (RPL) Remarks RPLSEC Resale Private Line (RPL) Secondary (SEC) SECLOC Local Response (LR) Secondary Location (SECLOC) SS Service Specific (see REQTYP) UNI UNI Circuit Detail Section of Resale Frame Relay Line CI Requested) use the following values for data element 234 to define the specific service requested. Valid DE 234 Entries: NL Non List Listing (See Note 6 in Appendix A) NP Non Publish listing (See Note 6 in Appendix A) OA Omit Address (See Note 6 in Appendix A) WIRN New Wiring Service Requested WIRP Partial Installed Wiring Service Requested WIRR Reuse Wiring Service Requested Common Language Equipment Identifier (CLEI) OBF maintains a list of Valid Values for Directory Listing Record Type (RTY) which may be used with the SH code. See the current issue of OBF Local Service Ordering Guidelines (LSOG) for a list of these values. SOURCE: (X12 Code Source 138) COMMON LANGUAGE Products AVAILABLE FROM: Telcordia Technologies COMMON LANGUAGE Products Customer Support Center 45 Knightsbridge Road Piscataway, NJ 08854 SV INTERNET: www.commonlanguage.com Load Sequence To be used with Sequence Override to identify that normal alphabetic sequencing in caption should be overridden for this listing. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). SH Service Requested When data element 235 = SH (Service Service Rendered When data element 235 = SV (Service Rendered) use the following values for DE 234 to define the specific service rendered. Valid DE 234 Entries: 0110 Recurring 0115 Trouble Isolation Plan/Maintenance 0200 Monthly Service Charge 0205 Basic Service 0210 Wiring 0215 Zone 0220 Summary Charge 0225 Mileage Charge 0230 Paging 0250 CENTREX/ESSX 0300 Access Charges 0315 Access/Data Services 0305 Service and Equipment Information 0310 CABS Facility Access 0400 Other Charges and Credits/Additions and Changes 0500 Itemized Calls 0510 Interexchange Carrier Invoice Charges 0520 Itemized Charges/Credits 0600 Directory Advertising 0700 Usage ABSTRACT: COMMON LANGUAGE Products provide the ability to communicate effectively within your company and with customers, suppliers, and other telecommunications providers. COMMON LANGUAGE products facilitate network and service management, increase operational efficiency, provide interoperability and increase customer satisfaction. They include Network Identification, Equipment Identification and Service Information. LS DESCRIPTION of DE235 Code 13 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE235 Code 0705 0710 0715 0800 0900 0905 1000 1100 1105 1110 1200 1250 1400 1410 1420 1425 1430 1450 1460 1500 1600 1605 1610 1615 1650 1700 1710 1720 1730 1740 1750 1760 1770 1780 1790 1800 1810 1820 1830 1840 1850 1860 1870 1880 1910 1920 CODE Measured Service Message Rate Service CABS Usage Optional Call Plan/Discount Plan Directory Assistance Direct Customer Access WATS Mobile/Cellular/Personal Communications Service Usage Airtime Roamer Equipment Testing Other Voice Services Advanced Intelligent Network ISDN Service VIP Remote Call Forwarding (RCF) Information Services Customer Owned Pay Telephone FAX Service Non-Voice Service Packet Switching Electronic Mail/Messaging Service CLASS Services Video Services Service Interruption Credit (See Note 4 in Appendix A) Customized Billing Service Non Recurring (See Note 4 in Appendix A) Rate Change (See Note 4 in Appendix A) Miscellaneous Service Order Installation (See Note 4 in Appendix A) Fractional (See Note 4 in Appendix A) Route Advance Call Trace Pulse Link Foreign Exchange (FEX) Voice Mail Extended Area Non regulated 976 Additional Usage Additional Calls 800 Common Line Billing/Transaction Processing Charges Data Conversion/Transmission DESCRIPTION of DE235 Code 1950 1960 1970 1980 1990 2000 2010 2020 2030 2040 2050 2060 2070 2110 2120 2130 2500 2600 WJ Charges InWATS/800 Service OutWATS Call Completion Ineffective Attempts Other Line Charge Command-A-Link Directory Product Alternate Destination Routing Charge Community Optional Calling Service Community Optional Service Usage Total Amount Billed (for Summary/Consolidated Billing Only) Set Use Fee Ring No Answer Contracts/Discounts Recharged Calls Transport Charges Purchases CABS Late Payment Charges Telecom Service Type When DE 235 = WJ (Telecom Service Type) use the following values for DE 234 to define the limited types of charges being billed. Valid values for DE 234: 1 Recurring Charge 2 Other Charges 3 Usage 4 Summary/Combined Charges Note: Code WJ will be available in 004020 (See Note 9 in Appendix A). For implementations based on X12 version/release prior to 004020 use "ZZ" instead. ZZ 559 Mutually Defined Agency Qualifier Code TYPE=ID MIN=2 MAX=2 Code identifying the agency assigning the code values. CODE BE DESCRIPTION of DE559 Code Telcordia Technologies SOURCE: (X12 Code Source 138) 14 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE559 Code 560 Special Services Code COMMON LANGUAGE Products TYPE=ID MIN=2 MAX=10 Code identifying the special service. AVAILABLE FROM: Telcordia Technologies COMMON LANGUAGE Products Customer Support Center 45 Knightsbridge Road Piscataway, NJ 08854 EGCS MAINTAINED CODE VALUES CODE Two-Tier Pricing Contract Administrative Overhead Percentage City CENTREX Line Capacity Contract Customer Calling Discounts Complex CENTREX Service Transport Facility Contract Commitment Plan Base CPB Commitment Plan CPL Commitment Plan Outage CPO Contract/Tariff Plan CT County CY Disabled Person Discount DP Dispute DSP Interstate/IntraLATA ER Federal FD Federal and State FS Intrastate IA Interstate IR Local LO Municipal MP Non Distinct ND Non Regulated NREG Optional Payment Discount OP Previous Bill(s) PB Percentage Pricing Contract Plan PP Promotion Discount PR Resolved-Customer RESCUS Resolved-Exchange Carrier RESEC Intrastate/IntraLATA RR Rate Stability Plan RS Special Assembly Charge SA State and Local SL State ST SUFINALT Set Use Fees (IntraLATA) SUFLOCAL Set Use Fees (Local) Service Outage SVO Termination Liability Charge TL Toll TOL Unresolved UNRES Volume Pricing Plan VP Variable Term Contract Pricing Plan VT Mutually Defined Z1 (See Note 1 in Appendix A) Mutually Defined Z2 (See Note 1 in Appendix A) INTERNET: www.commonlanguage.com ABSTRACT: COMMON LANGUAGE Products provide the ability to communicate effectively within your company and with customers, suppliers, and other telecommunications providers. COMMON LANGUAGE products facilitate network and service management, increase operational efficiency, provide interoperability and increase customer satisfaction. They include Network Identification, Equipment Identification and Service Information. TI DESCRIPTION of DE560 Code 2T AO CA CC CD CMPLX CP Telecommunications Industry SOURCE: (X12 Code Source 46) Telecommunications Industry Codes EDI Telecommunications Service Characteristics Qualifiers and Codes AVAILABLE FROM: Alliance for Telecommunications Industry Solutions (ATIS) 1200 G Street, N. W., Suite 500 Washington, DC 20005 (202) 628-6380 INTERNET: http://www.atis.org ABSTRACT: The Guidelines and Service Characteristic Qualifiers and Codes list the suggested codes to be used in the industry. The codes in the Guidelines are subsets of the ASC X12.3 Data Element Dictionary. The Service Characteristic Qualifiers and Codes contain the industry-maintained codes for the service ordering and billing processes in the industry. 15 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE Z3 Z4 Z5 Z6 Z7 Z8 Z9 ZZ INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE560 Code CODE DESCRIPTION of DE751 Code Mutually Defined (See Note 1 in Appendix A) Mutually Defined (See Note 1 in Appendix A) Mutually Defined (See Note 1 in Appendix A) Mutually Defined (See Note 1 in Appendix A) Mutually Defined (See Note 1 in Appendix A) Mutually Defined (See Note 1 in Appendix A) Mutually Defined (See Note 1 in Appendix A) Mutually defined (See Note 1 in Appendix A) FMW HDW MS MTL PLG SFW SS Firmware Affected Hardware Affected Major System Affected Material Affected Plug-in Affected Software Affected Subsystem Affected QR1 - Activity Codes CODE DESCRIPTION of DE751 Code AL CA Quality or Reliability Alert Report. Corrective Action/Quality Improvement Report Independent Validation Audit Sample – Supplier Internal Report of Periodic (Re) Qualification Quantity Allocation Only Report of Material Disposition Supplier Data Report Report of Software Metrics Independent Validation Audit Sample – Non-Affiliate DV PQ QT RD SD SM VA 751 Product Description Code TYPE=AN MIN=1 MAX=12 A code from an industry code list, which provides specific data about a product characteristic. AFCHAR – Affected Characteristics Codes CODE FI MA PO RE SF SV TF TR DESCRIPTION of DE751 Code QR2 - QA Sample Status Codes Fire Affected Maintenance Affected Power Affected Reliability Affected Safety Affected Service Affected Traffic Effected Transmission Affected CODE R S X DESCRIPTION of DE751 Code C DD H IC ICR N TC V W Y Completed Document Distribution Telco Hold Installer Change Installers Change Rotation Not Working – Awarding Material Telco Responsible for Change Vendor Hold Workable - Material has Shipped Cancelled CODE PHYCHAR – Physical Characteristics Codes CODE Samples Not Included Samples Included Validation Audit Samples are not to be Counted with Routine Q&RC Data SO-RSQ - Service Order - Reseller Questions List PCNSTAT – Product Change Notice Codes CODE DESCRIPTION of DE751 Code DESCRIPTION of DE751 Code AA Change to End User Information Valid Entries in DE1073 (PID08) Y = Change to End User Information N = No Change to End User Information AB Change to Directory Listing Information Valid Entries in DE1073 (PID08) Y = Change to Directory Listing Information N = No Change to Directory Information AC Dispatch Required Valid Entries in DE1073 (PID08) Y = Dispatch Required N = No Dispatch Required DESCRIPTION of DE751 Code 16 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE DESCRIPTION of DE751 Code AD Reference of Calls Requested Valid Entries in DE1073 (PID08) Y = Reference to Calls Requested N = No Reference to Calls Requested AE Yellow Pages Advertising Follow-up Requested Valid Entries in DE1073 (PID08) Y = YP Advertising Follow-up Request. N = No YP Advertising Follow-up Request. AF End User Moving Indicator Indicates when the end user location is changing. A yes/no flag to indicate that end user address information may be required to ensure eligibility for telephone number portability. Valid Entries in DE1073 (PID08) Y = End User is Moving N = End User is not Moving AG Network Interface Device Request Valid Entries in DE1073 (PID08) Y = Network Interface Device Requested N = Network Interface Device not Request. AH Coordinated Hot Cut Valid Entries in DE1073 (PID08) Y = CHC is Requested N = CHC is not Requested AI Pair Gain Valid Entries in DE1073 (PID08) Y = Pair Gain used for this Request N = Pair Gain not used for this Request AJ CENTREX Services Valid Entries in DE1073 Y = Dial 9 for outside line N = Don’t dial 9 for outside line AK Loop out of range Valid Entries in DE1073 (PID08) Y = Loop is out of Range N = Loop is not out of Range AL Network Interface Device Reuse Valid Entries in DE1073 (PID08) Y = Reuse Network Interface Device N = Do not reuse Network Interface Device AM INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE DESCRIPTION of DE751 Code Valid Entries in DE1073 (PID08) Y = Jack is Requested N = Jack is not Requested AN Special Construction is Authorized Valid Entries in DE1073 (PID08) Y = Special Construction is Preauthorized N = Special Construction not Preauthorized AO Agency Authorization Status Valid Entries in DE1073 Y = LSP is authorized as end user’s agent N = LSP is not authorized as end user’s agent AP Additional Point of Termination Indicator Valid Entries in DE 1073 (PID08) Y = APOT field contains the CLLI code AQ Existing Advertising (EA) Valid Entries in DE1073 (PID08) Y = End User has existing advertising N = End User does not have existing advertising U = Unknown AR Omit Telephone Number Valid Entries in DE1073 (PID08) Y = O - Omit telephone number AS Listed Name Placement Valid Entries in DE1073 (PID08) Y = L - Letter placement AT Address Indicator Valid Entries in DE1073 (PID08) Y = O - Omit address in DA and directory AU Advanced to Directory Indicator Valid Entries in DE1073 (PID08) Y = Listing be advanced to publisher in order to meet a book closing AV Street Address Directory Valid Entries in DE1073 (PID08) Y = O - Omit listing from street directory AW Direct Mail List Valid Entries in DE1073 (PID08) Y = O - Omit from direct mail lists Jack Request 17 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE AX DESCRIPTION of DE751 Code Telemarketing Valid Entries in DE1073 (PID08) Y = O – Omit from telemarketing lists AZ Dual Name Listing Indicates listing contains multiple first names. Valid Entries in DE1073 (PID08) Y = Dual Names are Listed N = No Dual Names are Listed BA Professional Identifier Indicates that this a professional listing. Valid Entries in DE1073 (PID08) Y = Professional Identifier is Used N = Professional Identifier is not Used BB Sequence Merge Valid Entries in DE1073 (PID08) Y = Merge across customers N = Do not merge between customers BD BE BF CODE No Solicitation Indicator Valid Entries in DE1073 (PID08) Y = Print indicator (Causes an identifying mark to be shown in the directory AY BC INDUSTRY CONVENTIONS ASC X12 Version 004050 Ten Digit Trigger Indicates the activation of a ten digit trigger for local routing associated with number portability. Valid Entries in DE1073 (PID08) Y = Ten Digit Trigger Activated Zero Logic Identifies if the customer's frame relay customer premises equipment (CPE) is unable to support B8ZS. Valid Entries in DE1073 (PID08) Y = CPE Supports B8ZS N = CPE does not Support B8ZS End User Form Indicates which additional forms are being submitted with this request. Valid Entries in DE1073 (PID08) Y = End User Form is Used N = End User Form is not Used Directory Assistance Indicates which additional forms are being submitted with this request. Valid Entries in DE1073 (PID08) Y = DA Form is Used N = DA Form is not Used DESCRIPTION of DE751 Code BG Directory Listings Indicates which additional forms are being submitted with this request. Valid Entries in DE1073 (PID08) Y = DL Form is Used N = DL Form is not Used BH Directory Listing/Assistance Indicates which additional forms are being submitted with this request. Valid Entries in DE1073 (PID08) Y = DL/DA Forms are Used N = DL/DA Forms are not Used BI Final Bill Information Indicator Indicates whether a final bill should be sent to either the existing billing address or a different address. Valid Entries in DE 1073 (PID08) Y = Different (D) N = Existing (E) BJ Operator Assisted Routing Identifies a requirement for custom routing of 0+ Local, 0-, 411, 555-1212 calls. Valid Entries in DE 1073 (PID08) Y = Customized Routing BK Station Messaging Detail Recording Identifies that the SMDR call detail recording system is actuated on all calls placed by station users. Valid Entries in DE 1073 (PID08) Y = Yes, if SMDR is used BL PBX Trunk Type Identifies the type of PBX trunk being ordered Valid Entries in DE 1073 (PID08) Y = C (Custom) BM Additional Field Visit Required Identifies if a field visit is required at the customer/end user location, which requires arrangements to be established. Valid Entries in DE 1073 (PID08) Y = Yes BN Negotiated Rate Indicator Identifies the rates that are to be applied to the service(s) being ordered.. Valid Entries in DE 1073 (PID08) 18 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE751 Code CODE Y = Negotiated Rates Apply BO BP Identifies a failed MLT test with a central office. Valid Entries in DE 1073 (PID08) Y = Yes (MLT test failed) Hunt Group Restriction Indicates the number(s) requested are not available for hunting due to technical restrictions. Valid Entries in DE 1073 (PID08) Y = Yes End User Retain Listing Indicates whether an end user’s directory and/or directory assistance listing should be retained or not retained. NOTE: As of LSOG6 the valid OBF values have been expanded. The valid value conversion for Y and N will not be used after ELMS5. Beginning with ELMS6 valid OBF values are passed unconverted in PID05. ELMS5 and Prior: Valid Entries in DE 1073 (PID08): Y = Retain End User Listings for this Account “as is” in both Directory and/or Directory Assistance N = Do Not Retain Listing ELMS6 and After: Valid entries in DE352 (PID05): OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. BR BS BT DESCRIPTION of DE751 Code Graceful Discard Indicates what the Frame Relay Graceful Discard feature should be set for. Valid Entries in DE 1073 (PID08) Y = A - Turn on N = B - Turn off Alternate Call Authorization Indicates authorization has been obtained to list the alternate number, when the requester is not the LSP owning the telephone listing. Valid Entries in DE 1073 (PID08) Y = Alternate Call/Answering Service Listing is authorized Failed Test BU Hunt Group Information Identifies that the Hunt Group Information is present in the Local Service Request . Valid Entries in DE 1073 (PID08) Y = Hunt Group Information is Used BV Quick Dial Tone Indicator Identifies whether or not a location has an available Quick Dial Tone (QDT) line. Valid Entries in DE 1073 (PID08) Y = Yes (QDT is available) N = No (QDT is not available) BX Range Extender Indicator Indicates the presence of a range extender on the loop. Valid entries in DE1073 (PID08) Y=Range Extender is Present BY Remote Terminal ADSL Available Indicates that the Remote Terminal serving the entire distribution area and all the serving area interfaces will have ADSL available. Valid Entries for DE1073 (PID08) Y=Indicates remote terminal has ADSL available BZ Pooling Status Identifies the pooling status of a Working Telephone Number (WTN). Valid Entries in DE1073 (PID08) Y=WTN is pooled N=WTN is not pooled CA Different Premises Address Indicator Identifies if the installation address is different from the listing address for at least one TN on this order. Valid Entries in DE1073 (PID08) Y=Installation address is different from the Listing Address for at least one TN N=Installation address is not different from the Listing Address CB Construction Required Indicator Identifies whether or not construction is required for this inquiry. 19 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE751 Code CODE Valid Entries in DE1073 (PID08) Y=Construction is required N=Construction is not required CD CE CF CG CH CI CJ DESCRIPTION of DE751 Code office voice repeaters on the loop. Valid Entries in DE 1073 (PID08) Y = Yes N= No Owned Wiring Indicator Identifies if the inside wiring of the validation address is owned by the end user. Valid Entries in DE1073 (PID08) Y=Inside Wiring is owned by the end user N=Inside Wiring is not owned by the end user Do Not Omit Indicator Identifies if the publisher should ignore the normal print-suppression of "ST" (Street). Valid Entries in DE1073 Y=Do no omit Technician Working on Ticket Indicates that a technician is currently working on the ticket for this request. Valid Entries in DE1073 (PID08) Y=The technician is currently working on it N=The technician is not currently working this order Reuse Loop Identifies the customer’s desire to reuse the loop from an existing service arrangement for this request. Valid Entries in DE1073 (PID08) Y = A – Yes Alternate Network Serving Arrangement Indicates that the customer is requesting an arrangement that allows end users who reside in areas where the central office switch does not support ISDN BRI to receive the service from a neighboring central office. Valid Entries in DE1073 (PID08) Y = Yes Display Identifies display functionality on the ISDN set. Valid Entries in DE1073 (PID08) Y = Yes Voice Repeater Presence Identifies the presence of analog central CK Data Repeater Presence Identifies the presence of data repeaters on the loop. Valid Entries in DE 1073 (PID08) Y = Yes N= No CL Digital Route Index Identifies the ISDN PRI route index as digital data only. Valid Entries in DE1073 (PID08) Y = Yes CM Conversion In Progress Indicator Indicates that conversion is in progress and CSR has not been updated. Valid Entries in DE1073 (PID08) Y = Yes CN Order Change Indicator Indicates if any service order details have changed between Pending Service Order Notices. Valid Entries in DE1073 (PID08) Y = Yes CO Pending Order Identifies if a pending order has been assigned to the PON. Valid entries in DE1073 (PID08) Y = Yes CP Diversity Indicator Indicates that there is an alternate transmission route. Valid entries in DE1073 (PID08) Y = Yes CQ English USOC Description Indicator Identifies that a description of a USOC will be required Valid entries in DE1073 (PID08) Y = Yes CR USOC Description Available Indicator Identifies that USOC descriptions are not available for the account Valid entries in DE1073 (PID08) N = No 20 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE751 Code CS MUX Status Identifies that a MUX (Multiplexer) is available for the facilities that have been queried. Valid entries in DE1073 (PID08) Y = MUX Available N = MUX Not Available CT Integrated Switched Digital Network (ISDN) Indicator Identifies that the facilities queried can support ISDN. Valid entries in DE1073 (PID08) Y = ISDN Capable N = Not ISDN Capable CU Switched Net 56 Indicator Identifies that the facilities queried can support Switched Net 56. Valid entries in DE1073 (PID08) Y = Switched Net 56 Capable N = Not Switched Net 56 Capable CV 64K Clear Channel Indicator Identifies that the facilities queried can support 64K Clear Channel service. Valid entries in DE1073 (PID08) Y = 64kbps Clear Channel Capable N = Not 64kbps Clear Channel Capable CODE DA DB DC CW CX CY DD X75 Packet Service Indicator Identifies that the facilities queried can support X.75 Packet Service. Valid entries in DE1073 (PID08) Y = X.75 Capable N = Not X.75 Capable Identifies if a working telephone number is being served via integrated pair gain/integrated digital loop carrier (IDLC) or non-integrated on a Batch Hot Cut Inquiry. Valid Entries in DE 1073 (PID08) Y = Yes N= No Easy Numbers Identifies a TN for a vanity or custom number. Valid entries in DE1073 (PID08) Y = Yes Merger Indicator A locally defined code to identify when pending order activity exists on a Customer Service Record but has not been posted to the account. Valid entries in DE1073 (PID08) are: Y = Yes N = No Independent Company Indicator Identifies that the specified address is not within the local company territory. Valid entries in DE1073 (PID08): Y = Yes N = No FCI - Fiber Capability Indicator Valid Entries in DE1073 (PID08) Y=Yes N=No Product/Service formatted Codes used in PID04 CODE DESCRIPTION of DE751 Code CMP Item Status of Complete Indicates the status of an item. Re-Qualification Indicates that an automatic requalification will be made if the initial request did not qualify Valid entries in DE1073 (PID08) Y = Yes N = No Switch Supported Identifies if a USOC feature is supported by the switch. OPT Barcode is Optional Indicates the Barcode is optional. Product/Service formatted instructions/details to be used with PID05 Description CODE DESCRIPTION of DE751 Code 800 800/WATS Instructions Remarks which define or clarify instructions for establishing 800/WATS service. Valid entries in DE1073 (PID08) Y = Yes U = Unknown CZ DESCRIPTION of DE751 Code ACCTDES Account Descriptor Locally defined code to indicate that the CSR inquiry is on an active account, but pending a disconnect. Integrated Digital Loop Carrier 21 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE DESCRIPTION of DE751 Code CODE DESCRIPTION of DE751 Code Identifies the physical point of termination at a collection cage. ALA Alternate Loop Available Indicates whether an alternate path from the DLC to the host central office is available. CFA Connecting Facility Assignment Identifies the carrier system and channel to be used. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. ARS Automatic Route Selection Identification of the facilities involved in a particular route and the sequence in which these facilities are accessed. contents are established as part of a trading partner agreement. CFAST CFA Status Locally defined code to identify if there is a conflict with the facilities that have been queried. DAT Display Attributes Identifies the attribute that provisions the display functionality on the ISDN set. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. ASGNIND Assignment Indicator Identifies an assigned or unassigned circuit at a given address. ASGTRSTN Assignment Restriction Code Locally defined code to identify restrictions against a specific CFA (Connecting Facility Assignment). DLCTYPE DLC Type Identifies the type of Digital Loop Carrier (DLC) on the loop. DSSCP DSSC Presence Identifies the presence of Digital Single Subscriber Carrier (DSSC) on the loop. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. BAI Billing Availability Indicator Identifies for LIDB that the end user's billing name and address is not available to anyone other than the current LSP, based on the end user's request. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. BCOPT Batch Cut Option A locally defined code that identifies the process to be used for a batch hot cut. BSVC Bearer Service Identifies the activated ISDN BRI B1 and B2 channels. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. CCEA Cross Connect Equipment Assignment EXP Expedite Reason Indicates the reason why an expedite is requested. FEATDES Feature Description Description of feature codes, which may include USOCs and FIDs. FE Facility Environment Identifies the type(s) of facilities deployed in the geographic area surrounding the end user location. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. FEP Facility Environment Provisioned Identifies the type of facility serving 22 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE DESCRIPTION of DE751 Code CODE DESCRIPTION of DE751 Code the end user location. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. FSQ Fiber Service Qualification Identifies the status of the fiber facilities serving the end user location. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. ISR Installation Service Requested Identifies that the customer is requesting a provider technician to assist the end user with installation and configuration of on-site equipment. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. ITYP ISDN Type Identifies the ISDN set configuration. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. LCT Load Coil Type Identifies the type of load coil(s) present on the loop (LSOG) for a list of these valid values. LPAC Loop Product Available Code Identifies which products are available for resale based on the loop length LSA Loop Speeds Available Identifies the specific xDSL downstream/upstream speeds that are available LTNE Listing Telephone Number Environment Identifies the service type associated with the telephone number for this listing MEU Multiple End User Functions Identifies the functions associated with the existence of multiple end user locations. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. MLT Mechanized Line Test Identifies the status of the mechanized line test. NCDEF Network Channel Code Definition Identifies a definition of the Network Channel (NC) Code (e.g., CO Multiplexing). PCT Primary Rate Interface (PRI) Call Type Identifies the allowable call types for the ISDN PRI. LLT Loop Length Type Identifies the process used to determine the loop length. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. PGPRES Pair Gain/DLC Presence LM Loop Make-up Type Identifies whether the loop qualification inquiry/response is based on the total length of the loop or each loop segment/sub-segment. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines POTSSPLITLOC Plain Old Telephone Service Splitter Location 23 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE DESCRIPTION of DE751 Code CODE DESCRIPTION of DE751 Code A locally defined code that indicates cable connection point for location of the POTS Splitter. SCFA Secondary Connecting Facility Assignment Identifies the provider carrier system and channel to be used from a wide band analog or a high capacity facility for a through-connect configuration. PPT Ported/Pooled Type Indicates that the telephone number has been internally ported or pooled. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. SSC Single Subscriber Carrier Indicator Identifies that two circuits are associated with the physical loop and the applicable connecting device. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. PROJIND Project Indicator Identifies that the project is either a customer or provider project. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. QRYIND Query Indicator Locally defined code to indicate the selection criteria used on a query (TN, ECCKT, address, etc.). STATUS Status of Channel A locally defined code that identifies the status of the channel. TA Terminating Arrangement Identifies that the ISDN/PRI is provisioned using another service type arrangement. RP Ring Preference Identifies the attribute associated with the call appearance of the ISDN set. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. RSUIND Remote Switch Unit Indicator Identifies that the loop originates from a Remote Switch Unit. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. RTF Receive/Transmit Indicator Identifies if a pair is used to support the receive or transmit side of a 4wire service. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. TAI Transaction Activity Indicator Identifies the status of the service order returned. TNE Telephone Number Environment Identifies the service type associated with the telephone number(s) for this request. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. TNT Test and Tag Requested Identifies the customer is requesting additional testing and tagging beyond that which is included with the product ordered. 24 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE DESCRIPTION of DE751 Code CODE OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Chart Type (see DE1271 for code list) SO-RSQ Service Order – Reseller Questions list (see DE751 for code list) TTYP Terminal Type Identifies the terminal associated with the ISDN BRI. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. 822 Source Subqualifier TYPE=AN MIN=1 MAX=15 A reference that indicates the table or text maintained by the Source Qualifier. CODE AFCHAR PHYCHAR Physical Characteristics (see DE751 for code list) CODE 0P QR2 Performance Credit Eligibility Indicator For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. 1P Specialized Transition Percent Percentage applied to switched access rate Pre-ordering Address Response code list (see DE1271 for code list) 2P CMC/RCC Percent Originating Usage Percentage used to bill cellular originating usage 3P Discount Rate Indicator A code which denotes that a discount rate is applied. Pre-ordering Feature/Service Response code list (see DE1271 for code list) For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. NOTE: This code and its associated DE1271 codelist should not be used with LSOG5 and later -- refer to DE 1000 code "FE", instead. QR1 DESCRIPTION of DE1000 Code Identifies the performance credit eligibility status. NOTE: This code and its associated DE1271 codelist should not be used with ELMS5 and later. PRE-FRESP TYPE=AN MIN=2 MAX=2 Code from an industry code list qualifying the type of service characteristics. (For three character codes, see Note 10 in Appendix A) Affected Characteristics (see DE751 for code list) Product Change Notice Codes (see DE751 for code list) PRE-ADDRESS 1000 Service Characteristics Qualifier DESCRIPTION of DE822 Code PCNSTAT DESCRIPTION of DE822 Code QR3 4P Non-Premium Percent Identifies the proportion of non-premium flat-rated usage to be billed. Activity Codes (see DE751 for code list) 8P QA Sample Status Codes (see DE751 for code list) POTS Translation Indicator A code that denotes the rate application for 800 database POTS translation 25 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE queries. C For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. 8V AC Virtual Features Indicator Automated Centralized Trunk Monitoring Valid DE234 values: B Both C Customer T Telecommunications Provider For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Account Activity Code AD Address Activity Indicates the activity of the work to be performed at the account level. An OBF value which indicates the address activity. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. EGCS Valid DE234 values: A Establish New Account C Change an existing account, e.g., rearrangement, move, partial disconnect or addition D Disconnect account in its entirety DN Deny/Non-Payment H Short Term Suspension M Inside move of physical termination within a building R Record activity is for ordering administrative changes RP Restore/Payment RS Restore Service S Reseller Assume SD Seasonal Disconnect SS Suspend Service T Relocate Service Location outside V Conversion of service as specified W Conversion as is AB Assumed Indicates that an automated service is provided which monitors customer use of specified central office loops for quality of voice or data transmission and operational performance. A code that denotes the rate application for 800 database vertical features. AA DESCRIPTION of DE1000 Code AE Account Code A customer selectable 2 - 12 digit code entered when placing a call and captured by the switch that appears on the customer’s bill. AF Address Format Type OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. AG PICC Apportionment Factor Application Indicator An indicator that denotes how the primary interexchange carrier apportionment factor is applied. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Contract Indicator Indicates whether charge items were part of original (baseline) contract or added to the baseline contract. AH Valid DE234 values: A Added B Baseline Primary Interexchange Carrier Apportionment ID A code which identifies the Primary Interexchange Carrier relationship as it 26 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE relates to Primary Interexchange Carrier apportionment factor. AO Valid DE234 values: 1 Base PICd to Individual Carrier 2 Total PICd to All IXC 3 Total Non PICd An alphanumeric descriptive translation of the account code or PIN that appears on the customer’s bill. AQ Valid DE234 values: 0 Answered 1 Unanswered 3 Blocked due to Irregularity 4 NCP Blocked Before Answer 5 NCP Blocked After Answer AR Primary Interexchange Carrier Apportionment Factor For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. CABS BOS value asterisk (*) will be presented as 'SOACT'. ACNA/State Indicator Valid DE234 values: SOACT Service Order Activity For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. AS Valid DE234 values: A Active B Resolving Error C Cancel D Consolidated F Final H Hold P Pending Q Order in approval process R Reactivated S Suspended V Converted Service Main/Alternate Telephone Number An OBF value which indicates the dialable Telephone Number(s) assigned to the ISDN BRI (Integrated Services Digital Network Basic Rate Interface) line. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). AN Account Status A EGCS defined code used to distinguish the status of service at an account. Alternative NPA NXX Identifies an alternative NPA-NXX where the feature/service is available AM Activity Indicator A code that denotes posted activity to an account since the last billing cycle. A code which identifies the specific level of apportionment detail. AL Type of Account For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. A factor used to apportion Non-PIC’d lines to all Interexchange Carriers. AK Translated Account Code/PIN Answer Indicator Indicates whether a call was answered or the reason that a call was not answered. AJ Provisioning Activity/Status A code or phrase that identifies provisioning activity or status of an item in a service order. AP AI DESCRIPTION of DE1000 Code AT Access Number Customer Access Treatment (CAT) Identifies the access treatment code assigned to a CENTREX station line. A dialed number used to access a specific telecommunications service. 27 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE AU AX INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Authorization Code for a list of valid values. This code is verified in the switch to authorize access to the network. Note this is not the same as CD, a user defined code not verified at the switch. A2 Access Type BA For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. BB BC Committed Burst Size Identifies the maximum amount of data that a user is permitted to offer to the network during time interval (Tc) across the circuit. BD Acceptance Testing Request Primary B/D Channel Configuration A 7 digit alpha/numeric code that identifies the ISDN PRI (Primary) B and D channel configuration per DS-1. Identifies the customer contact telephone number when acceptance testing is requested for ISDN or xDSL Capable Loop. BE Tandem Switching Charge Type Indicator Excess Burst Size Identifies the maximum amount of data that a user is permitted to offer to the network that exceeds Bc during time interval (Tc) across the circuit. Identifies the type of tandem switching charge being applied. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. A1 Blocking Activity An OBF value which identifies the blocking activity. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Address Delivery Type An OBF defined value that identifies an address as being valid for hand delivery, postal delivery or both. This only indicates the validity of an address for a particular delivery method and cannot be used to request a specific delivery method. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). A0 Band Locally defined code to identify an area in which a call/service terminates. Valid DE234 values: DD Dedicated IT Interconnection Trunking LA Local LI Link SP Special SW Switched AZ Call Appearance Identifies the call appearance(s) on the ISDN set. Identifies the access circuit type. AY DESCRIPTION of DE1000 Code BG Location Billing Group Identifies a group of stations by customer location for the application of billing rates. Actual/Assumed Usage Indicator BI A code that identifies usage as being based upon actual recorded usage or assumed usage. Assignable Binding Post Identifies the binding post associated with a fiber channel used to support the end user. For CABS billing applications, see current issue of OBF CABS BOS Specifications 28 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE BL INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE BU Identifies the central office that provides bridging for multi-point services. BN Billing Telephone Number BW Business/Residence Placement Override BZ For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. BIP (Border Interconnection Percentage) CA Valid DE234 values: 0 Access charges do not apply 1 Access charges apply 3 Ratchet Factor Supplemental BIP (Border Interconnection Percentage) CB Directory Listings Type of Account CC Calling Card Number Identifies the card number(s) assigned by the telecommunications provider. CD Billing Structure Code Customer Dialed Acct. Recording/Subauthorization Number A numeric code of 1/8 digits assigned by the customer at the time the call is placed. A locally defined code that identifies the billing structure for an account or type of billing detail within an account. BT CENTREX Common Block Identifier Identifies the name/number of the CENTREX and the name/number of the grouping (Customer Common Block). An OBF value that identifies the type of account for a directory listing which determines the placement in split directories and directory assistance. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). BS Carrier Access Line Charge Code A EGCS defined code indicating if carrier access line charges apply. A Meet Point Billing percentage applied to fixed charges. BR BIP Source Indicator A code that denotes the source of the BIP. The percentage of a specific rate element that is to be billed by a given exchange carrier or to be rated under a given jurisdiction's tariff on a multiple jurisdiction account. BQ Bandwidth Identifies the number of bands used in conjunction with multi-bandwidth services. An OBF value that identifies an override of the normal placement of a business or residence listings. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). BP Billed Network Address/User ID The primary/originating data services network address/user ID in a transmission, which incurs charges. Identifying number to which charges are directed. This number may incur its own charges. BO DESCRIPTION of DE1000 Code Bridging Location Code CE Cellular Air time Package Code A code that uniquely identifies the schedule of air time usage charges for a customer's cellular calls. Basic Service Type Locally defined code which identifies the basic service type for the account. This may be the Basic Class of Service USOC. 29 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE CF INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Configuration Code (See Note 2 in Appendix A) CJ Used to determine if the TCD amount is included in the SLN. Use of this code is temporary and will go away with ANSI ASC X12 Release 003021 when DE662 is added to TCD. Valid DE 234 values: D Disconnect N Add/Install CK Contract Category Code CL Charge/Usage Status Code Valid DE234 values: B Business C Coin E ESSX/CENTREX F Flat Rate Residence G Government M Measured Rate Residence O Other R Residence For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Valid DE234 values: 00 Zero Rated 01 Current 02 Revised 03 Rate Change 04 Free Item 05 Order Activity Charge 06 Prior to Rate Change 07 After Rate Change 08 Previous 09 Variable Rate CM Local Service Providers Circuit Number Identifies the circuit number assigned by the Local Service Provider. May also be used by the customer as a cross reference to the provider's circuit ID(s) and in many cases to identify the customer's end-toend service. CMA CI Class of Service Code A EGCS defined code to identify the class of service for this account. A code indicating whether the charge is current, revised or other. CHC Circuit Location Code A customer defined code to identify the circuit location. A locally defined code to identify a contract category not a specific contract number. CH Treatment Code Activity Indicates the activity type for the treatment code associated with the CENTREX Common Block. Valid DE234 values: I TCD value is included in the SLN if it is a child of the SLN. If not, it is included in the IT1. O Informational Only CG DESCRIPTION of DE1000 Code Commingling Arrangement Coordinated Hot Cut Identifies that the customer is requesting near seamless cutover activity. Identifies the billing configuration in a commingled service arrangement for same bandwidth segments. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Circuit Drop Location Code OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Circuit Number Identification Code CN Identification code for the circuit number. A code to identify a specific customer location for a service item, circuit or data link connection identifier (DLCI). CO Central Office Exchange Code 30 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE A locally defined code to identify the Central office serving the account. Usually the 3-digit code known as Prefix in a dialed telephone number. Could be NXX of NPA Plan. CP CPG CQ Service Ordering Guidelines (LSOG) for a list of these valid values. CW CX Call Pickup Group Identifies the call pickup group to which this line is to be assigned. CENTREX Multi-Group Number CY OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Calling Card Restriction CZ Circuit Signaling Condition For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Common Language Segment Number (SFN) C0 OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Channel Pair Identifier The channel of a hi-cap facility used for a switched access service. CV Circuit Switched Data Configuration Identifies the quantity of ISDN BRI B channels which will allow or deny access to an individual ISDN user. A locally defined code to identify the individual segments (Sections / Legs) of a multi-point circuit for access services, special services, or telephone lines. CU Cellular Usage Indicator A code used to identify cellular usage and separate cellular usage type. Indicates the type of conditioning necessary to elevate transmission quality within specific parameters set for the circuit. CT Type of Cable Identifies the type of cable associated with the loop or loop segment. This element identifies the type of restrictions associated with a calling card. CS CENTREX Location Address Code A locally defined code that identifies a location address for the CENTREX equipment. The address may identify a customer, or company address. This element identifies a grouping of CENTREX stations for a Secondary Location Address (SLA). CR Out Exchange Company Circuit ID Identifies the circuit identification that was previously provided to the old LSP/NSPSwitch by the NSP-Loop. Channel Type Indicates the channel type as specified in the telecommunications provider's tariff, which is utilized in providing data services. DESCRIPTION of DE1000 Code C1 Cable Type Indicator Channel Number Identifies the specific channel number on a circuit that the customer is requesting to use. Identifies the configuration of the facility connection assignment. C2 OBF maintains a list of valid values that may be used with this field. See Local Call Forwarding Telephone Number Indicates the telephone number to which 31 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE calls will be directed for Interim Number Portability. C3 Service Ordering Guidelines (LSOG) for a list of these valid values. Header Telephone Number DA Identifies the telephone number on level 0 for a directory listing caption header or SLU header. C4 Valid DE234 values: 01 Local 02 Intrastate/Intraprovincial 03 Intrastate/IntraLATA 04 Intrastate/InterLATA 05 Interstate/Interprovincial 06 Interstate/IntraLATA 07 Interstate/InterLATA 08 Corridor 09 411 10 555 11 Both 411 and 555 combined 12 International 13 Intrastate beyond service area 14 Interstate beyond service area 15 Intrastate Operator 16 Interstate, Canada and/or 809 17 Multi-Listing 18 Multi-Listing by appointment 19 Call Credit 20 Interstate Operator Handled 21 Information Call Completion 22 Intrastate Call Completion 23 Interstate Call Completion 24 Name/Address 25 InterLATA 26 555 National 27 411 National 28 555 Information Call Completion 29 411 Information Call Completion 30 555 Name/Address 31 411 Name/Address 32 Business Listing 33 555 Business Listing 34 411 Business Listing 35 Message Delivery 36 North America Header Non-Standard Telephone Number Sequence Telephone Number Identifies the telephone number of the indent line that is followed by a sequence override C6 File After Non-Standard Telephone Number Identifies the non-standard telephone number of the indent line that is followed by a sequence override. C7 Circuit Switched Voice Identifies the number of B channels available for voice per user profile. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. C8 Circuit Switched Voice Configuration Identifies which B channel will be used for voice. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. C9 Directory Assistance Category Code A EGCS defined code to identify the type of directory assistance billing. Identifies the non-standard telephone number in a directory listing caption header or SLU header. C5 DESCRIPTION of DE1000 Code DB Circuit Switched Data Directory Book Code The Yellow Pages Publishing Association (YPPA) Directory Publication code. Identifies the number of ISDN BRI B channels available for data. SOURCE: Publisher Contact List OBF maintains a list of valid values that may be used with this field. See Local 32 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE DESCRIPTION of DE1000 Code customer defined category. AVAILABLE FROM: Yellow Pages Publishing Association Operations Group 820 Kirts Blvd - Suite 100 Troy, MI 48084 (248) 244-6200 (248) 244-0700 (Fax) DJ Sub-Departmental ID Code Identifies specific groups or sub-groups within the department identifier. Primarily used by the customer, usually for billing reference purposes. INTERNET: www.yppa.org DK DC An OBF value which identifies CENTREX dialing capability. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). A EGCS defined code to distinguish the item as originating or terminating. Valid DE234 values: C Combination of originating and terminating O Originating T Terminating LM Land to mobile ML Mobile to Land MM Mobile to mobile DD DL Digits Outpulsed Primary/Originating Exchange Carrier Circuit (ECCKT) Data Link Connection Identifier (DLCI) DM DN DO Degree of Indent DI Do Not Abbreviate An OBF value that indicates data in supplied fields must not be abbreviated. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Identifies the degree of indentation for a listing. DH Directory Book Name The name of the Directory Book that is used when the Yellow Page Publishing Association code is not available. Directory Subsection Identifies the subsection of a directory in which to place the listing. DG Dialable Station Number Identifies the dialable 1 - 7 digit Station Digit Dialing number. Identifies the near and logical primary addresses of a Frame relay permanent virtual circuit. DF Delivered Line Speed This code defines the line speed to be delivered to the customer at the interface point. This code is used only when the requested line speed, i.e., the raw bandwidth provided by the carrier is different than the line speed required by the customers application. The unit of measure will always be in bits per second (BPS). Number of digits forwarded. DE Dialing Direction Code Discount/Promo Application Code Code to identify a type of discount or special promotion application. DOS Department Code/Customer ID Code DP Directory Order Status Identifies the status of the directory order. Different Premises Address/Location Code Identifies the customer location when services are provided at a location A locally defined code to further identify the charges and/or equipment by 33 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE different than that of the primary service, e.g., a PBX off-premises extension. DQ E N Data Service Classification DV Code identifying the Data Services. DW DX DS DY Disassociated Telephone Number Action Identifies the activity involved against the disassociated telephone number. Data Rate Testing Locally defined code that identifies the requested data rate at the time of turn-up for digital loop requests. Discount Planned Code OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Valid DE234 values: I Include X Exclude For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. DZ Directory Advertising Category Code Valid DE234 values: 01 DA Issue Billing 10 DA Monthly Billing 15 DA Adjustment 20 Credit/Debit 25 DA Sales 30 Increase in DA 35 Decrease in DA Dialed Telephone Number The dialed telephone number associated with a call when different than the To/Terminating Number. DU Directory Book Type Valid DE234 values: 01 Yellow Pages 02 White Pages Locally defined code to identify the discount plan. DT Detect Number A EGCS-maintained code to determine type of directory book. Reason for Disconnect DRT Diversity from Circuit Number Identifies the customer assigned telephone number associated with this loop request. Locally defined code that identifies the reason for disconnecting service. DRT Existing New This code specifies that the circuit being ordered should be provisioned such that its path does not coincide with the path of another (new or existing) circuit. Valid DE234 values: ACC Frame Relay Access APT Access Port CNM Customer Network Management Service DLC Data Link Connection Identifier DRC Disaster Recovery ECO Extended Connectivity Option GPV Global Permanent Virtual Circuit GPT Global Port LOC Location PVC Permanent Virtual Circuit PRT Unbundled Local Switching (Port) UKN Unknown DR DESCRIPTION of DE1000 Code Directory Caption Header Status Identifies whether it is a new header or a recap of an existing header, which is supplied to define placement within the caption set. D0 Disassociated Telephone Number Identifies the telephone number that is disassociated from the DID telephone number range. Valid DE234 values: 34 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE D1 INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Service Ordering Guidelines (LSOG) for a list of these valid values. Data Set Options - Add Indicates the options to be added to a data set ordered by the customer or presently installed on the data line. D2 D3 EC Data Set Options - Delete Indicates the options to be deleted from a data set ordered by the customer or presently installed on the data line. ED Data Terminal Address Identity EJ Data Unit Interface Functions EK OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Data Unit PIN Connector Set-Up EM Data Unit Loop Back Test Options EN Multiple Data Mounting Address Code Earning Number An identifying number that can actually incur charges. EO EO Service or Equipment Indicator Identifies the type of service/equipment associated with the line in the Line Information Database (LIDB). Distinctive Ring Telephone Number Identifies the additional telephone number(s) associated with unique ringing. D9 Electronic Mail Category Code A locally defined code identifying the category for the Electronic Mail service. Specifies the address of a multiple data set mounting device or modem pooling address. D8 Electronic Key Telephone Set Identifies the terminal set associated with the national ISDN. Indicates Loop back test options on data unit interface. D7 Easy Word Justification Identifies the justification of the EWORD field. Indicates which PIN on the Data Unit enables or disables the loop back testing capability. D6 Disconnect ECCKT Identifies the ECCKT to be disconnected. Indicates Data Unit Interface function conventions; such as EIA (Electronics Industry Assn.) Interface conventions. D5 Exception Character A locally defined field that identifies any specific digits that are to be bypassed in assigning a telephone number. Indicates the customer provided identifier for a data channel terminal unit. D4 DESCRIPTION of DE1000 Code For a list of Valid Values used with this code refer to the Telcordia Technologies document SR-4111, Originating Line Number Screening (OLNS) Planning and Implementation Guide. Disabilities Indicator Identifies for LIDB that the end user has a disability that requires special handling of operator-assisted and/or directoryassistance calls. EP Primary/Originating ECCKT ID The exchange carrier circuit ID used for billing purposes. OBF maintains a list of valid values that may be used with this field. See Local 35 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE ES ET INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Secondary/Terminating ECCKT ID FE Indicates Pre-ordering Feature/Service Response Code List. Electronic Serial Number OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. FF This is the disconnected telephone number from which calls are being transferred. Valid DE234 values: ADET Activity Detail Easy Word to Find FI FL Facility Charge Type Indicator For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Assembled Facilities Status From/Originating Station Telephone Number Identifies the condition of the existing facility(s) as assembled in the field. Telephone number from which the call originated. FN FO OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. FC Firm Order Confirmation Indicator A locally defined code that indicates the status of the Firm Order Confirmation (FOC). Facility Complement Code FP This code is used to identify the prepaid facility through which the service will be provided. FD Foreign Language Indicator Identifies the foreign language preference associated with the line number. Identifies the type of access facility charges being billed on a facility access account. FB Facility Interface Code Identifies the Facility Interface Code (FIC) for Customer Premises Equipment (CPE) which translates to the Network Channel Interface. Allows a selection of TN's that consist of letters and numbers that make up a word. FA Transfer Of Calls From Number End User Activity Code identifying the activity detail that will occur only at the end user account level. EZ Feature/Service Status The exchange carrier circuit ID used for billing purposes. Identifies the electronic serial number or a part of the serial number associated with a specific cellular telephone. EUA DESCRIPTION of DE1000 Code Link Management Protocol Identifies the Virtual Connection (VC) status for signaling protocol. Valid DE234 values: 1 LMI 2 Annex A 3 Annex B 4 Auto 5 Other (e.g., RLMI version) Feature Data This code is used to pass data associated with Service Feature/Option code, DE1000 code SF or SC. 36 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE DESCRIPTION of DE1000 Code 6 FQ INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE None may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Tariff Status A locally defined field used to provide current status of the service abbreviation in the tariff. FR EGCS Valid DE234 values: A Freeze LSP’s IntraLATA PIC B Freeze LSP’s Inter & IntraLATA PIC E Freeze LSP’s InterLATA PIC J Freeze LSP End User Customer’s InterLATA PIC K Freeze LSP End User Customer’s IntraLATA PIC L Freeze LSP End User Customer’s Inter & IntraLATA PICs R Remove InterLATA-Freeze S Remove IntraLATA-Freeze T Remove Inter & IntraLATA Freezes Fiber Ring Identifier A locally defined code used to specify the Fiber Ring Name to which requested service should be connected. This is also used for disaster recovery and diversity planning. FS Foreign Serving Office (FSO) A locally defined code identifying the switching central office unit. Usually represented in NPA-NXX format. FT F1 Foreign Township F2 Pricing Flex Indicator See Telcordia Technologies practice BR795-450-100 for a list of valid values to be used in DE234. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. F3 Pricing Flex Band – 2 See Telcordia Technologies practice BR795-100-100 for a list of valid values to be used in DE234. A locally defined code which identifies the second pricing flexibility band or area. FZ Location A A standardized code that uniquely identifies the location of facility terminal A, which has the lower in alpha/numeric sequence of two facility location codes in a connecting facility arrangement. Pricing Flex Band A locally defined code which identifies the pricing flexibility band or area. FY Facility Type A code that describes a type of facility when it is other than a single baseband channel on cable. A code that denotes whether pricing flexibility rates were applied. FX Facility Designation A code that, for a specific type of facility, uniquely identifies a path between two network nodes. Identifies the name of the Foreign Township used to determine the Telephone Directory that the customer’s listing should be placed. It is normally used for Customers with multiple listings. FW DESCRIPTION of DE1000 Code F4 Freeze PIC Indicator. Location Z A standardized code that uniquely identifies the location of facility terminal Z, which has the higher in alpha/numeric sequence of two facility location codes in a connecting facility arrangement. Indicates the customer’s desired freeze option for the PIC. OBF maintains the list of valid values that 37 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE DESCRIPTION of DE1000 Code assigned to a station line. See Telcordia Technologies practice BR795-100-100 for a list of valid values to be used in DE234. GB OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. General Exchange Tariff Options Billing Telephone Number (GBTN) GT An OBF value which identifies the Billing Telephone Number or Billing Account Number for charges associated with options such as inside wire time and material charges. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). GC Identifies the actual type of pair gain when present. HC Terminal Configuration Group Name Valid DE234 values: 01 Included HG HT HY Hunt An OBF value which indicates the type of hunting being requested. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. Global Circuit Number IA A locally service provider defined value that identifies a global circuit. A global circuit is comprised of one or more circuits (DE1000 = CN) from one or more service providers. Service Disconnect/Interruption Indicator. Identifies whether non-payment of a charge item is service affecting. EGCS Valid DE 234 values: DN Deny/Non-payment Dialing Plan Group IB Identifies the dialing plan name for a specific CENTREX. GS Hunting Telephone Number Identifies a hunting number within a hunting group. Glare Identifies who will yield in a call contention situation. GR Hunt Group Code A code which identifies the hunt group number on an account. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. GN Hotel Commission Flag This code indicates whether the toll message is included in the calculation of hotel commission. Identifies a group of features selected by the customer and is applicable only when a feature key button is activated on the ISDN set. GL Pair Gain Type ISDN Basic Rate Interface (BRI) Type An OBF value that indicates the type of National ISDN Basic Rate Interface (BRI). For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Terminal Group Station Restriction Identifies the CENTREX station restriction 38 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE IC INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Interexchange Carrier Serving Office Code with Number Portability in the current issue of OBF Local Service Ordering Guidelines (LSOG). A locally defined code to identify the Interexchange Carrier central office serving the account. May be a Common Language Location Identifier (CLLI) code. ID IQ Terminal Group Name IR IF Installation Disconnect Code IG EGCS Valid DE234 values: I Install D Disconnect B Both Install and Disconnect Digits In An OBF value which identifies the transaction activity. For a list of Valid Values used with this code See the current issue of OBF Local Service Ordering Guidelines (LSOG). IS OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. IT Interim Card Ported Telephone Number (s) Identifies the telephone number (s) that is/are to be retained (ported) for Number Portability. This code specifies that on a customer calling card order, interim cards are to be used for the order. Additionally the interim cards will be used with the same number that will be assigned to the customer cards. IV Inside Wire Type Identifies the type of inside wiring to be used. Valid DE234 values: Y Yes, issue interim card N No, do not issue interim card OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. International Card Number This code identifies the international card number(s) assigned by the telecommunications provider. IP Sub-loop Indicator Identifies the type of sub-loop the customer is requesting. Identifies the number of digits out-pulsed from the end user equipment to the providers central office. IN Transaction Activity Testing Indicator Locally defined code to indicate the type of testing requested. IM Transaction Type An OBF value which identifies the type of transaction. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Identifies the terminal group name used to provision CENTREX-like lines. IE DESCRIPTION of DE1000 Code IW Inside Wire Options An OBF value which identifies the requirements for inside wire services. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Number Portability Type An OBF value which identifies the type of action to be taken when doing number portability. For a list of Valid Values used with this code see the practices dealing IX Inside Wire Billing Account Telephone 39 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Number associated with this request. To identify the billing account telephone number for the charges associated with inside wire. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). I1 KL KP Telephone Number Indicator KR KS Out Telephone Number Indicator (OTNI) KT K0 Demarcation Designation Cross Box Identifier Identifies the provider's cable to be connected to the customer's terminal in a field location. K1 Current Activity System ID Identification of the Local Service Provider’s system to be used in a colocation arrangement. A locally defined code that identifies the cable pair unit current activity status. K2 Cable Identification Cable Pair Unit Pending Activity Status Identification of the Network Provider’s central office cable to be connected to the Local Service Provider’s co-located equipment. A locally defined code that identifies the cable pair unit pending activity status. First Unit K3 A locally defined code that identifies the inter-office or tie cable first unit by number. KG Cable Connection Type A locally defined code that identifies which cable connection type is being specified. Identification of the point where the network provider terminates service at the end user’s premises. KF Key System Number Identifies the customer equipment, or group of extensions, to which this item of equipment is related. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. KB Inventory Status A locally defined value that identifies the status of the co-providers POTS splitter or cable connection. Identifies that the telephone number in the OTN is served from either the customer’s switch or the provider’s switch. KA Plain Old Telephone Service Splitter A locally defined code that identifies the co-providers POTS splitter OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. J5 Last Unit A locally defined code that identifies the inter-office or tie cable last unit by number. Identifies that the telephone number(s) in the TNS field is served from either the customer’s switch or the provider’s switch. I2 DESCRIPTION of DE1000 Code Shelf Number assigned to the Local Service Provider’s shelf to be used in a co-location arrangement. Package Indicates the ISDN BRI feature package K4 Slot 40 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE rate center directory by LATA, and LATAs by NPA and NXX. Updated twice a year. Identification of the Local Service Provider’s specific connection slot to be used in a co-location arrangement. K5 LB Relay Rack Channel/Pair LC Identification of the specific channel or pair within the Network Provider’s central office. K7 Unit LD LE Listing Type Identifies the type of directory listing being submitted within the publication and directory assistance (DA) rules. Cable Identification 2 Identification of the second Network Provider’s central office cable in response to mechanization of line splitting. LA Low Speed Service Deriving Code (LSSD) A locally defined code used to align the customer service record. Slot Port Identifies the specific connection port of the slot to be used. K9 Library Code A two position alphanumeric code that references the Distance Dialing Reference Guide (DDRG) Toll Library Directory as defined in the Telcordia Technologies EMI standard (SR-STS-000320). Identification of the panel, shelf, or case within the Network Provider’s central office bay or cabinet. K8 Listing Activity Indicator (LACT) An OBF value that identifies the activity involved on a directory listing request. For a list of valid values see the current issue of OBF Local Service Ordering Guidelines (LSOG). Identification of the bay/cabinet in the Network Provider’s central office. K6 DESCRIPTION of DE1000 Code OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Local Access Transport Area (LATA) Code EGCS Valid DE234 values: 1 Listed, appears in DA & directory 2 Non-Listed, appears only in DA 3 Non-Pub, does not appear in directory 4 Non Pub Emergency, does not appear in directory, customer may be contacted in an emergency 5 Non Pub Special, does not appear in a directory, customer never wants to be contacted 6 Omit DA, listing only appears in the published directory A code to identify a geographic area. SOURCE: LATA Directory AVAILABLE FROM: Center for Communications Management Information 11300 Rockville Pike, Suite 1100 Rockville, MD 20852-3030 1-888-ASK-CCMI (1-888-275-2264) INTERNET: www.ccmi.com LF ABSTRACT: CCMI's LATA Directory shows area codes and exchange numbers within each LATA across the U.S., including LATAs within states, numeric list of LATAs, alphabetical list of LATA names, Line Class Code Identifies functionality of the line as it pertains to the type of switching equipment. Used with CENTREX/ESSEX services. For POTS, line class codes, 41 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE DESCRIPTION of DE1000 Code control routing for certain services. LN LG The telephone number as it appears on the directory listing for the account. Identifies the telephone number as it will be given in directory assistance. LO LH Late Payment Charge Applicability/Impact Indicator For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. LP LQ For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Local Transport Code LS A code which identifies the type of traffic to which local transport charges apply. Local Serving Office (LSO) A locally defined code identifying the central office unit associated with the wire center that services the subscriber premises. Usually represented in NPANXX format. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Loop Make-Up Status LT Location Type Indicates the type of circuit location. Identifies the status of the loop make-up returned. Valid DE234 values: 01 Master 02 Primary 03 Remote 04 Secondary 05 Alternate Master OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. LM LPC Type A code which identifies the type of late payment charge. Valid DE234 values: 1 Initial Portion 2 Continuation Portion 3 Ending Portion LK Transmission Level Point Identifies the required transmission level when a non-standard interface is required at the primary/secondary location. Long Duration Indicator A code used to indicate the portion of a long duration call when the call spans billing periods. LJ Local Exchange Carrier Serving Office Code A locally defined code identifying the Local Exchange Carrier Central Office serving the account. This code may be in Common Language Location Identifier (CLLI) format. Identifies whether a debit adjustment affects the calculation of late payment charges. LI Listed Telephone Number Listed Telephone Number DA Location Routing Number (LRN) LV A number (NPA-NXX / NPA-NXX-XXXX) used to uniquely identify a switch that has ported numbers and is used to route a call to the switch that owns the NPA-NXX portion of the LRN. LATA Wide Factor Identifies the number by which the usage rate has been multiplied for a LATA Wide trunk group. 42 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE LW INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE LATA Wide Indicator L3 A code that denotes whether the associated usage is toll free within the LATA. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. Local Exchange L4 Indicates the provider’s NPA/NXX. LY Multipoint Leg Activity For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. L5 Freeze Local Service Provider (LSP) For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. L6 OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. LPC Type Rate – Local A code which indicates the type of late payment charge rate applicable for the local jurisdiction. Spectrum Management Class For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Spectrum Management Classes represent the speed of data transmission and whether the data is transmitted in a symmetrical versus asymmetrical manner. Classes are defined by T1E1.4. L2 LPC Type Rate – Intrastate A code which indicates the type of late payment charge rate applicable for the intrastate jurisdiction. Identifies that the end user has requested the option of prohibiting the change of their current service provider or removing the option. L1 LPC Type Rate – Interstate A code which indicates the type of late payment charge rate applicable for the interstate jurisdiction. Identifies the activity that is occurring on this leg per this request. LZ Local Calling Scope Identifies the Local Calling Scope options being requested. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. LX DESCRIPTION of DE1000 Code L7 LPC Type Rate A code which denotes the type of late payment charge rate applicable. Loop Status For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. L8 Digital Subscriber Line Class of Service Identifies the ISDN BRI line class of service. OBF maintains a list of valid values that 43 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. MA ME Special Message Adjustment Code Valid DE234 values: 01 Transfer State Tax 02 Other Line Charges – Mexican Portion 03 Set Use Fee 04 Other Line Charges – Canadian Portion 05 Transfer Local Tax 06 Conference Surcharge 07 Authorization Code Surcharge Type 1 08 Conversion Surcharge 09 High Capacity Surcharge 10 Queuing Surcharge 11 Intelligent Call Processing Surcharge 12 Announcement Timer Surcharge 13 Alternate Termination Sequence Surcharge 14 Alternate Destination Routing Redirection Surcharge 15 Network Remote Access Surcharge 16 Originating LEC Switched Access Surcharge 17 Terminating LEC Switched Access Surcharge 18 Announcement Surcharge 19 Authorization Code Surcharge Type 2 Valid DE234 values: 01 Adjusted cutoff (CTO) 02 Adjusted poor transmission (PRT) 03 Rebill 04 Rebill and credit applied 05 Message Credit 06 Part Charge 07 Credit miss-rated message Missed Appointment Code Identifies the provider’s code for the missed appointment. MB Mail Box Identifies a mailbox in which information is stored and retrieved. MC Message/Rate Class Indicates what method was used to place the call. Valid DE234 values: AB Automated Billing Service (0+ Calling Card, Automated Collect and Automated Third Number) DS Dial station (Includes both domestic and International Direct Distance Dialing (DDD) OC Operator Completed with Dial Rate Applied OS Operator Station PC Person Call Back PR Person ST Station MD Multiple Charge Component (See Note 4 in Appendix A) A code used to qualify the multiple charge component for itemized calls. This code is temporary and should not be used after the ITA segment is added to TCD loop. This code indicates that this is an adjustment to a current/previous message charge. MAC DESCRIPTION of DE1000 Code MF Primary Rate Interface (PRI) ISDN Method Selection Identifies the "B" channel selection method used by the end user's equipment. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. Miscellaneous Description Locally defined text description to identify components of itemized call charge. This is a temporary code that should not be used once the ITA segment is added to the TCD loop. MG Migration Indicator Identifies the type of account level activity when lines/numbers are converting from 44 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE traffic type. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. MO MH A code which identifies the percentage of Total Minutes for Use in a state billed to a given ACNA. Special Message Information Code Qualifier For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Indicates special and/or supplemental information about the rating for a toll message. MP Loop Modification Type MQ Identifies the loop changes involved in this service request. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Market Segment MR OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guideline (LSOG) for a list of these values. ML Transmission Medium Type Identifies the specific medium or system type supporting the loop segment. OBF maintains a list of valid values that may be used with this code. See the Local Service Ordering Guidelines (LSOG) for a list of these values. Message Delivery Identifies the message delivery service that appears on the telephone bill. MS Valid DE234 values UR Urgent MN Meet Point Billing End Office A code that denotes the type of meet point billing arrangement(s) applicable at the end office. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. MK Meet Point Billing Valid DE234 values are: 01 Multiple Bill 02 Combination Meet Point 03 Single Bill-Multiple Tariffs 04 Single Bill-Single Tariff 05 Single Bill-Pass Thru 06 Single Bill-Special Access Valid DE234 values are: 01 Time and Charge Quoted 02 Indicates a Toll Message Spanned Multiple Rate Periods 03 Pay Phone Non-Revenue Call 09 Postalized Rated Call MJ MOU Apportionment Month Conveys the “month” in which a charge was incurred MI DESCRIPTION of DE1000 Code one LSP to another LSP. Special Message Discount Code Locally defined code indicating that the message is entitled to a special discount. Meet Point Billing Traffic Type MT A code that denotes the type of meet point billing arrangement(s) applicable to the Message Type A EGCS maintained code identifying a characteristic of a message in respect to 45 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE billing. DESCRIPTION of DE1000 Code OC Operator Assisted Calling Card (See Note 2 in Appendix A) OD Operator Handled – Direct Dialed Rate (See Note 2 in Appendix A) OH Operator Handled – Calling Card/Person-to-Person (See Note 2 in Appendix A) OP Operator Assisted Person-toPerson (See Note 2 in Appendix A) OS Operator Assisted Station-toStation (See Note 2 in Appendix A) PR Person (See Note 2 in Appendix A) PT Prompter (See Note 2 in Appendix A) RP Receipt Paid SA Sent Paid – Person to Person (See Note 2 in Appendix A) SC Special Collect SP Sent Paid / DDD ST Station (See Note 2 in Appendix A) TF Toll Free – Reverse Bill TG Telegram (See Note 2 in Appendix A) TN Third Number TP Operator Handled – 3rd Number Person-to-Person (See Note 2 in Appendix A) WD WATS Message Detail (See Note 2 in Appendix A) Valid DE234 values: AB Automated Billing Service Third Number (See Note 2 in Appendix A) AC Automated Billing Service Collect (See Note 2 in Appendix A) AD Automated Billing Service Calling Card (See Note 2 in Appendix A) AH Attendant Handled (See Note 2 in Appendix A) AL Alternately Billed AN ANI (See Note 2 in Appendix A) CA Collect – Person to Person (See Note 2 in Appendix A) CB Collect – Station to Station (See Note 2 in Appendix A) CC Calling Card CD Domestic Calling Card (See Note 2 in Appendix A) CF Conference (See Note 2 in Appendix A) CL Collect CP Coin Paid CW Call Forward (See Note 2 in Appendix A) DO Direct Dialed – Operator Number Identification (See Note 2 in Appendix A) FC Florida COCOT calls (See Note 2 in Appendix A) IA Intra-state (See Note 2 in Appendix A) IC International Calling Card calls (See Note 2 in Appendix A) IR Inter-state (See Note 2 in Appendix A) IT International calls (See Note 2 in Appendix A) LI Local Interrupt (See Note 2 in Appendix A) LV Local Verify (See Note 2 in Appendix A) MC Messenger Charge (See Note 2 in Appendix A) MO Mainland Originated (See Note 2 in Appendix A) NM Non-Mainland Originated (See Note 2 in Appendix A) OA Operator Assisted Conference Call (See Note 2 in Appendix A) MU Maintenance Center Identifies the maintenance center associated with the service order. MV Minutes of Use (MOU) type A code which identifies minutes of use quantity type when used in a calculation. Valid DE234 values: A Adjusted R Recorded TA Total Adjusted MW Mid Span Percent A percent used to bill the appropriate amount of local channel charges for Intrastate and Interstate jurisdictions on a 46 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE DESCRIPTION of DE1000 Code mid-span service. M6 MX Identifies the proximity of the disturber within the feeder facility(ies). The extension used to identify a specific voice mailbox. MY OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. Multi-Line Indicator An indicator that distinguishes multi-line or non multi-line (single) applicability. M6A For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. MZ MUX Type OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. M7 F2 Loop Composition OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. OBF maintains a list of valid values that may be used with this code. Se Local Service Ordering Guideline (LSOG) for a list of these values. M8 F2 Disturber Type Identifies the type of disturber present in the distribution facility(ies). F1 Disturber Type OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. Identifies the type of disturber present in the feeder facility(ies). OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. M5A F1 Loop Composition Identifies the composition of the loop material (serving technology type) of the feeder facility(ies). Identifies the composition of the loop material (serving technology type) of the distribution facility(ies). M5 Alternate F1 Location Identifies the proximity of the alternate disturber within the feeder facility(ies). A code that denotes the type of multiplexing charge applied. M0 F1 Disturber Location Mailbox Extension M9 F2 Disturber Location Identifies the proximity of the disturber within the distribution facility(ies). Alternate F1 Disturber Type OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. Identifies the type of the alternate disturber present in the feeder facility(ies). OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. NA Network Addressing Method Code Indicating the Network Addressing 47 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE DESCRIPTION of DE1000 Code method being used. Indicates the electrical and physical interface between the telecommunications provider office and the customer location. Updated codes can be obtained by contacting ATIS at 202-628-6380 and requesting A Technical Report on Carrier to Customer Installation Interface Connector Wiring Configuration Catalog. Valid DE234 values: E1 E.164 E2 DS1 NB Nearby Telephone Number Identifies the telephone number that may be at or adjacent to the requested service delivery location. NC NJ Network Channel Code Identifies the electrical connotation on the circuit at the secondary ACTL or primary location. Identifies the network channel code for the circuit(s) involved. It describes the channel provided by the exchange company between two customer locations. ND NE NK Identifies network path rating points. Identifies the end user telephone number to be disconnected in association with unbundled services. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. NP Digital Services Network Assignment North America Numbering Plan (NANP) Code Area Code. SOURCE: (X12 Code Source 719) NANPA – North American Numbering Plan Administration Notification Type Identifies the type of notification being sent to the customer. AVAILABLE FROM: NANPA – North American Numbering Plan Administration 46000 Center Oak Plaza, Building 10 Sterling, VA. 20166 OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. NG Network Path Indicator Disconnect Number Identifies the circuit number associated with the ISDN BRI. NF Secondary Network Channel Interface Code (SECNCI) Network Point Indicator INTERNET: http://www.nanpa.com A code that identifies at which point in the network a charge is being assessed. ABSTRACT: Provides and maintains a list of telecommunications carrier identification codes which are used in the ordering and billing of telecommunications services. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. NQ NH Identifies the status of the telephone number being ported. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Identifies the end user’s new telephone number. NI Number Portability Indicator Telephone Number Change Network Channel Interface Code 48 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE NS INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Non-Standard Telephone Number OC Identifies a telephone number that is not in the North American Numbering Plan such as, a vanity number, 911, or enterprise numbers. NT Valid DE234 values: (See Note 6 in Appendix A) 02 Annual Inventory 06 Out of Service 08 Miscellaneous Activity 12 Service Order Activity 14 Deposit Refund 16 Interest on deposit 18 Installment Billing 20 Rate Change 22 Fractional 24 Fractional Credit (See Note 4 in Appendix A) 26 Non-recurring 28 Non-recurring Credit (See Note 4 in Appendix A) 30 Gift certificates 32 Installation 33 Change in Primary Interexchange Carrier (PIC) Shared Line Telephone Number Network User Identification (NUI) Code A locally defined code to identify the network subscriber. NW New Construction Identifies that the service address is a new construction or a new location within an existing service address. OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. NY Other Charges and Credits Category Code A EGCS maintained code identifying the basic category for this charge or credit. Identifies the end user telephone number(s) for line sharing. NU DESCRIPTION of DE1000 Code Disassociated Telephone Number Type A Identifies how the disassociated telephone number is to be used. A01 A02 A03 A04 OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. B N1 Primary Number B01 Identifies a shared telephone number when the number in the TNS field will appear as a secondary line on an ISDN set. N2 B02 B03 N3 Border Interconnection Percentage (BIP) Change C Indicates charges or credits related to additions, changes, or deletions in monthly recurring events: Addition, change or deletion related to monthly recurring events Due to change in billing Data Out Telephone Number C01 Identifies the existing data telephone number that is being changed. Indicates charges or credits related to a change in rate: Charge or credit related to rate change Carrier Access Line Rate changed to discount rate B04 Data Telephone Number Identifies the packet telephone number associated with the ISDN. (See Note 5 in Appendix A) Indicates an adjustment related to partial month charges or credits: Adjustment related to partial month charges or credits Service billed before connection Service Outage/Interruption Suspension of Service C02 49 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code C03 C04 C05 C06 C07 D CODE Directory advertising Promotional credit/discount/gift Reversal of credit due to early removal Service discontinued by provider Reversal of promotional credit H01 H02 H03 H04 H05 H06 H07 D10 Indicates adjustments related to previously billed events: Adjustment related to previously billed event Directory advertising Directory assistance Error in billing rate Tax Surcharge Late payment charge Disputed amount Transferred Billing Charges/Payments On discount D11 D12 D13 D14 D15 Non-recurring credits or charges Recurring Credits or Charges Usage Sensitive Additional Media/Report/Study Equipment E E01 E02 E03 E04 E05 Indicates credits due to refund: Refund Interest Deposit Regulatory Overbilling F Indicates charges or credits due to banking transactions: Charge or credit due to a banking transaction Dishonored check/electronic funds transfer D01 D02 D03 D04 D05 D06 D07 D08 D09 F01 F02 G H08 H09 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H20 H21 H22 I G02 G03 G04 G05 G06 Indicates charges or credits due to installment billing transactions: Charge or credit related to installment billing Construction installation Transfer to a new number Repair Connection/equipment Interest H Indicates charges or credits due G01 DESCRIPTION of DE1000 Code I01 I02 I03 I04 I05 J J01 J02 J03 to non-recurring events: Charge or credit related to nonrecurring event Premises visit Materials/equipment Labor Materials/equipment and labor Central office connection Processing/conversion/service ordering Installation/Establishment /Activation One-time Pre-subscribed Interexchange Carrier (PIC) activity (See Note 7 in Appendix A) Additional media/report/study Shipping/handling Construction Expedite Change/rearrangement/removal Usage sensitive Gift of service/installation Foreign directory Discount on installation Directory Advertising/Listing Promotional Credit/Discount/Gift Penalty Tax Indicates charges or credits due to Pre-Subscribed Interexchange Carrier (PIC) activity (See Note 8 in Appendix A): Charge or credit related to Presubscribed Interexchange Carrier activities Disputed amounts Carrier merger No selection Promotional Pre-subscribed Interexchange Carrier change Indicates Charges or Credits due to IntraLATA PreSubscribed Interexchange Carrier (LPIC) Activity Charge or Credit related to IntraLATA Pre-Subscribed Interexchange Carrier (LPIC) Activity Establishment Change 50 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE DESCRIPTION of DE1000 Code J04 J05 J06 J07 OD INDUSTRY CONVENTIONS ASC X12 Version 004050 CODE Discontinue No Selection Assigned Promotional Change list of these valid values. EGCS Valid DE234 values: A Additional line requested V Validate status of existing service Other Charges and Credits Description Code OR Valid DE234 values: EO Engineer Only EF Engineer & Furnish EFI Engineer, Furnish & Install EI Engineer & Install FI Furnish & Install FO Furnish Only IO Install Only Service Order Type A locally defined value used to identify the status of the order. OF Retrieve Orders Indicates search criteria for Posted Orders. OL Type of Engineer Order To identify the various types of orders issued on TEO’s. A locally defined code to specifically identify the type of charge or credit being applied. This may be an OC&C phrase code. OE DESCRIPTION of DE1000 Code OS Other Service Type A locally defined code to identify the service type associated with the other Network User Address. From/Originating Location The originating location of a call or circuit. OM OT Originating/Terminating Rate Indicator Identifies the existing telephone number that is being changed. Identifies the rate applicable to originating and terminating minutes of use. OW For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. ON Other Network User Address OBF maintains a list of valid values which may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. PA Outgoing Only Service Code (OGO) An outgoing only service identifier associated with a telephone number. OP Type of Pulsing Outward Identifies the type of pulsing requested from the provider to the customer. The packet switching network user ID in a transmission to which the usage charge is not being applied. OO Out Telephone Number Primary/Originating Message Carrier Identification A locally defined code which identifies a third party service provider for billing. Working Service On Premises PB A code that indicates that there is a working service at the end user location. Point Of Termination (POT) Bay Type Identifies the location of the POT Bay and who is responsible, ILEC or CLEC, for installation and maintenance. For a list of Valid Values used with this code see the current issue of the OBF Local Service Ordering Guidelines (LSOG). OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a 51 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE PI PC DESCRIPTION of DE1000 Code Pager Cap/Code Proprietary Classification Pager network identifier. Indicates the type of an account’s proprietary restrictions per the customer’s request. PD PJ Indicates the rating quantity which is applied at the line level when the PICC is assessed. Number Portability Direction Indicator Identifies the direction of wireless conversion activity PK PL Identifies the service code of the PBX private line ports required when connecting private line service to registered systems. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Valid DE234 values: OF Fully protected private line ports ON Non-protected private line ports OP Partially protected private line ports OX Ancillary Equipment EGCS Valid DE234 values: DP Dial Pulse MF Multi Frequency DTMF Dual-tone Multi Frequency PM Telephone/Pin Number associated with a pager. PN Valid DE234 values: DT Data Transport FS Fast Select HP Holding Time Premium HS Holding Time Standard PC Protocol Conversion Personal Identification Number (PIN) Identifies the Personal Identification Number. PO Provider Initiated Activity (PIA) Indicates a provider initiated response that is not a result of a customer Local Service Request or supplement prior to completion. PICC Capacity Type Indicator Channels Indicates the rating quantity which is applied at the channel level when the PICC is assessed. PH Pager Number Packet Switching Service Type A EGCS maintained code identifying a Packet Switching Service Type. PG PBX Private Line Service Code Pulse Type Type of pulsing on the type of trunk. PF Previous Provider Telephone Number Identifies the end user’s previous listed telephone # if the user is changing providers. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. PE PICC Capacity Type Indicator Lines OBF maintains a list of valid values that may be used with this code. See Local Service Ordering Guidelines (LSOG) for a list of these values. PICC Capacity Type Indicator Trunks Indicates the rating quantity which is applied at the trunk level when the PICC is assessed. PP Packet Switch Port Identifies the access port to the packet 52 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE switched network. PQ may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Major Product Code Locally defined code to identify the type of product to which the charges are grouped. PR EGCS Valid DE234 Values: L Line Port T Trunk Port Protocol Type PX A code used by the customer to specify the type of transmission protocol required. PY For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Packet Switching Category Code PZ Valid DE234 values: CO Canada – Overseas CU Canada – United States DO Domestic IA Intra-network IL Intra-LATA IO Inter-office IP Intra-office IR Inter-network For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. P0 For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Percent of Interstate Usage (PIU) P1 Sensor Identification Code Qualifier A locally defined code related to packet switching, which uniquely identifies the sensor where the record was recorded. For PAD (Packet Assembler / Dissembler) generated records, the sensor identification may be the unique PADNCC/INF code. Percent Available Specifies the percent of a facility that is available for ratcheting. PW Pricing Plan Type Indicator A code which denotes the type of pricing plan. Pre-assigned Telephone Number Specifies the percent of interstate traffic, a physically intrastate circuit carries or is capable of carrying. PV PICC CENTREX Indicator Identifies the CENTREX line formula used in the assessment of PICC. Indicates a new telephone number that is assigned by the customer. PU PICC Application Indicator Indicates the type of PICC being applied. A EGCS defined code to identify the package switched service category type. PT Private Branch Exchange/CENTREX Extension Number The local extension number associated with a PBX or CENTREX. Valid DE234 values: X25 X.25 X400 X.400 ASYC Asynchronous SYNC Synchronous PS DESCRIPTION of DE1000 Code Port Type P2 Identifies the type of unbundled port ordered from the provider. Remote Sensor Identification Code A locally defined code related to packet switching which uniquely identifies the remote node PAD (Packet OBF maintains the list of valid values that 53 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Assembler/Dissembler) that originally creates the usage measurement contained in the call detail record. P3 transaction when there are multiple selections available for a single transaction type. Originating Data Network ID Code QD A locally defined code related to packet switching that identifies the calling network. Terminating Data Network Identification Code For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Originating Type A locally defined code related to packet switching that identifies the type of access (dialed, dedicated) and access protocols of the connected originating end users. P6 QT Terminating Type Valid DE234 values: 01 Additional Minutes (See Note 2 in Appendix A) 02 Average minutes per call (See Note 2 in Appendix A) AF1DQ Alternate F1 Disturber Quantity BTQ Bridge Tap Quantity CCH Composite Channels CH Channels F1DQ F1 Disturber Quantity F2DQ F2 Disturber Quantity GC Gigacell LCQ Load Coil Quantity MAXB Maximum B Channels MDPK Maximum D Channel Packet Usage MTER Maximum Number of Terminals NR New Rate PL Per Line RPET- Repeater Quantity RQTY RPL Required Plan SBCH Split Billed Channels SC System Capacity SUCH Shared Use Channels TCCH Tandem Routed Composite Channels TCH Tandem Routed Channels TST Tests VPL Variable Plan Originating Tariff Utility A locally defined code related to packet switching that identifies the type of access arrangement at the originating network. P8 Terminating Tariff Utility A locally defined code related to packet switching that identifies the type of access arrangement at the terminating network. P9 Pricing Plan Level Indicator A code which denotes the level at which a pricing plan exists. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. QC Quantity Qualifier The code used to qualify the quantity appearing in the QTY segment associated with the SI to which it is paired. A locally defined code related to packet switching that identifies the type of access (dialed, dedicated) and access protocols of the terminating connected end users. P7 Minutes/Query Indicator A code used to identify database usage measurement values. A locally defined code related to packet switching that identifies the called network. P5 Quick Dial Tone Number Identifies the telephone number of a QDTqualified telephone line. QM P4 DESCRIPTION of DE1000 Code Transaction Class For ordering purposes, a locally defined code that identifies the class of a 54 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE RA INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Routing Arrangement For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Identifies a grouping of WATS/800 access lines and their service area. RI RB DESCRIPTION of DE1000 Code Route Index Related Committed Burst Size Identifies the index used by the Service Provider’s switching equipment. Identifies the maximum amount of data that a user is permitted to offer to the network during time interval (Tc) across the related circuit. RJ Rate Zone Identifies the applicable zone rate. RC Rate City For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Identifies the city used as the basis for rate calculation. This may be different than the actual service location city. RK RD Identifies the rate band for a specific type of equipment. Identifies the speed of the port of the related circuit. RE For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Requisition Type An OBF value that identifies the type of requisition being requested. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). RF RL Related Circuit Number RM Revenue Code A locally defined code that identifies the applicable journal or revenue code associated with the itemized charge/adjustment. Regulatory Agency RN This code identifies the regulatory agency responsible for the tariff under which the service is being ordered. RH Requested Location The location for which a telephone number is provided in a directory assistance call. This element identifies the circuit identification number(s) of a circuit already in service or being provisioned. RG Equipment Rate Band Related Port Speed Requested Telephone Number The telephone number requested and provided in a directory assistance call. Valid DE234 values: FCC Federal Communications Commission PUC State Public Utility Commission CRTC Canadian Radio and Telecom. Commission RO Rate Category Indicator RP Requested Local Serving Office A locally defined code used by the customer to identify the provisioning office. This code, when resent, supersedes the default local serving office field (LS). Rate Period Code A EGCS maintained code identifying the rate period in which the message occurred. Indicates the specific switched access rate category being adjusted. 55 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. RV RW EGCS Valid DE234 values: N Non-Regulated Y Regulated RX Requested Number RY Valid DE234 values: L Local Service T Toll Service Related Committed Information Rate RZ EMI Record Identification The Exchange Message Interface (EMI) Record ID as defined in the Telcordia Technologies EMI standard (SR-STS000320). Rate Schedule R0 Service Center Route Code Identifies the code for the route followed by the technician during his daily calls. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. R1 Rate State Repeater Type A locally defined code that indicates the type of repeater on the loop. Identifies the state used as the basis for rate calculation. This may be different than the actual service location state. RU Local/Toll indicator Identifies whether a charge or credit is related to local service or toll service. Identifies the rating schedule used to calculate usage charges. RT Related Excess Burst Size Identifies the maximum amount of data that a user is permitted to offer to the network that exceeds Bc during time interval (Tc) across the related circuit. Identifies the rate of ingress traffic across the related circuit under normal conditions. RS Regulation Indicator Identifies whether the charge was a regulated or non-regulated service. This element identifies a number(s) or a range of numbers requested by a customer that has not been previously reserved. The number entry may include a “W” for a wild card entry to indicate any number can be provided in that position. RR Reserved Number Identifies the number(s) to be reserved by the telecommunications provider for future use. Valid DE234 values: 01 Peak 02 Off Peak 03 Day 04 Evening 05 Night/Weekend 06 Weekend (when separate from night) 07 Special Intrastate 08 Late night 09 Regular (Non time of day WATS) 10 Discount 11 Economy 12 Prime 13 Standard 14 Multi-period RQ DESCRIPTION of DE1000 Code R2 Routing Indicator Rate Country A code which identifies how usage was routed through the network. Identifies the country used as the basis for rate calculation. For CABS billing applications, see current 56 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE issue of OBF CABS BOS Specifications for a list of valid values. R3 RF RL RS S SS V W X Y Remote Switching Unit Type A locally defined code to indicate the type of remote switching unit (RSU). R4 Remote Terminal Indicator A locally defined code that indicates that the loop originates at a remote terminal. R5 SB For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Restore Type SC A locally defined code that indicates the type of suspension being restored. SA Remove Feature(s) Relocate Service Location Restore Service Reseller Assume Suspend Service Conversion as specified Conversion as is Exclude Deny Switch Type Indicates the type of local serving office switch that is used to provide the BRI. This information may be needed to correctly configure the end user’s customer premises equipment. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Rate Source Indicator Identifies the source for the billed rates. R6 DESCRIPTION of DE1000 Code Service Category Code A locally defined code identifying the service category. This may be a USOC. Service Activity Code SD A EGCS maintained code identifying the type of activity resulting in an OC&C item being created. Settlement Code This code provides a greater level of detail regarding zone rate or origin and termination of the message and/or usage service, charge or credit. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Valid DE234 values: AA Intra – Canada AB Intra – US/US AC Intrastate – Independent Exchange Carrier/Independent Exchange Carrier AD Intra – Non-US-NANP AE Intrastate – Intracompany AF Intrastate – Intercompany EE Interstate – InterLATA ER Interstate – IntraLATA IA Intrastate IAMA IntraMTA-Intrastate IAME IntraMTA-Interstate IB Interstate – Independent Exchange Carrier/Independent Exchange Carrier IC Interstate – US/Alaska, Hawaii, Puerto Rico & US Virgin Islands ID Interstate – Intracompany IE Interstate – Intercompany For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. EGCS Valid DE234 values: A Add AF Add Feature(s) C Change CF Change From CT Change To D Delete H Short Term I Include L Seasonal P PIC Change R Record – Information only RA Record Activity – Add RD Record Activity – Delete 57 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE IEM IEMA IEME IR IT IU IY IYN IYS LO NA NB InterMTA InterMTA – Intrastate InterMTA – Interstate Interstate International Interstate – US/US Intermediary Intermediary Non-Settlement Intermediary Settlement Local International – US/Canada International – International Point/International Point NC International – US or Canada/International Point ND International – US/Mexico NJ Non-Jurisdictional NS Non-Standard OC Outside Specified Area OF Offshore OS Overseas RE Intrastate – InterLATA RR Intrastate – IntraLATA WC Inside Specified Area SE ISDN BRI in instances of multiple IXC selection, e.g. One IXC is requested as the PIC and one B channel providing voice and another IXC is requested as the PIC for the second B channel providing just data. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). SI SJ SK Station Digit Dialing Identifies the dialing patterns of the CENTREX common block. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Secondary/Terminating Exchange Carrier Circuit (ECCKT) Data Link Connection Identifier (DLCI) SL Secondary Location Address This element identifies an address for a primary termination of CENTREX service or Direct Inward Dialing trunk in addition to the customer’s main address. Service Feature/Option Code SM Speed Call Group The speed calling group number for a station line or the line number for each line in the group. For ordering purposes suggested DE234 values are in Appendix C. Service Group SN Identifies a grouping of access lines/service. ISDN Service Profile Identifier (ISPID) Provides a code that must be programmed into the ISDN BRI customer premises equipment (CPE). This code is transmitted from the CPE over the ISDN BRI D-channel to the LSO switch. It must be present in order for the BRI to become active. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. SH Special Exemption for Customer Service Information Identifies the special exemptions associated with the end user’s account. The code value in DE 234 may be a USOC, FID or valid Company code. A locally defined code to identify the features and options for the associated service, e.g., CENTREX line station features; call waiting, call pickup. SG Circuit Number Special ID A locally defined alphanumeric code that further identifies a circuit. Identifies the near and logical secondary address of a Frame relay permanent virtual circuit. SF DESCRIPTION of DE1000 Code Switch Data Identifier SO Identifies the type of Switched Data for Additional Scoping ZIP Code 58 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE DESCRIPTION of DE1000 Code CA On Demand Call Feature Activation CE Cellular CF Non-Dial Conference CH Non-Dial Conference Leg CI Dial Conference Bridge CR Cost Recovery CW Call Forward DI Digital E911 Enhanced 911 FC Florida COCOTS FE Foreign Exchange FX Fax IA Intra-switch IE Inter-switch IN Inward Calls (excluding WATS/800) LI Local Interrupt LV Local Verify MC Messenger Charge MO Mainland Originated NM Non-Mainland Originated NS Non-Subscriber Service Charge ON ONI (Operator Number ID) PP Payphone PT Prompter PV Private Line RA Network Remote Access TA Trace Activation TG Telegram VM Voice Mail WD WATS Message Detail Identifies additional descriptive scoping information required to identify the directory in which to place the listing. SP Special Payment Indicates that a charge applies to a special billing/payment commitment plan. Valid DE234 values: CP Commitment Plan Applies PP Payment plan commitment applies TP Hi-capacity term pricing applies SPG SQ Secondary Call Pickup Group Identifies the secondary call pickup group arrangement(s) to which this line is to be assigned. Sub-Product Code A locally defined code to provide segregation of billing details by subproduct code. SR Special Routing Code A code that identifies the type of special routing being requested. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). SS Service Sub-category Code SU A locally defined code that further defines the service category. This code may or may not be used in conjunction with Service Category Code. ST Secondary/Terminating Network Address/User ID The secondary/terminating data services address/user ID in the transmission. SV Message Service Type Service Configuration Identifies the way in which an existing service is configured. Type of message service being billed. Valid DE234 values: 211 Information Referral 311 Non Emergency 511 Transportation Information AH Attendant Handled/Operator Handled AN ANI (Automated Number ID) BR Branding – OA (Operator Assistance/DA (Directory Assistance) OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. SVC Service Level Identifier Identifies the level of service the customer is requesting. 59 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE SW INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Switchboard ID S3 S4 S5 Start Signaling For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Scoping ZIP Code S6 Switch Indicator A locally defined value that identifies that the LSO has multiple switches or a single switch associated with the location, if known. TA Timing Source Identifies the ZIP or Postal Code used to aid in identifying the directory in which to place the listing. S0 S1 Suspend Activity Indicator Indicates the type of suspend activity being requested. Identifies the source of timing. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. USOC Surcharge Applicability Indicator EGCS Valid DE234 values: 1 Internal 2 External 3 Loop C Customer T Telecommunication Provider’s Indicates a surcharge is applicable to a specific USOC For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. S2 Sonet Ring Mileage Indicator A code which denotes whether the billing of mileage is for the full Sonet ring or point to point. Identifies type of start signaling requested. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). SZ Section A locally-defined code that identifies the section of the service order where the FIDs or USOCs are located in (e.g., S&E, BIL). Two-Six Code (FID TSC) The unique identity assigned to message trunks within a telecommunications company. SY Status of Service Order Identifies the status code/description of the service order. Identifies the auxiliary switchboard associated with this equipment item. SX DESCRIPTION of DE1000 Code TB Subtotal Type Blocking/Billing Exception Indicates blocking and/or billing exception on designated line(s). Denotes the type of Customer Service Record (CSR) subtotal OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. 60 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE EGCS Valid DE234 values: A No collect and/or third number B No third number C No collect call D No 1+ dialing E No 0+ dialing F No 1+ and 0+ dialing G No 011 dialing H No directory call assistance call comp. J No 700 dialing K No 976 dialing L No 915 dialing M No 900 dialing N No Casual Calling (10 P No N11 (except 911 and 411) Q No 411 R No Incoming (CENTREX) S No 976, 900-303, 900-505 T No 900-303 W No 7 digit Toll (CENTREX) Y No 500 TC TG TH TI Termination ID Identifies the type of termination equipment used for a private line access. TJ Terminating User Identifies the user of the service to be billed as itemized usage. Transfer Announcement Number Valid DE234 values: NS Non-Subscriber SR Subscriber TK Transmission Duplex Trunk Number/Identification Identifies individual trunks in a trunk group. TL To/Terminating Location The terminating location of a call or a circuit. Valid DE234 values: F Full Duplex H Half Duplex I In Only O Out Only T Two Way TM Transmission Speed TN To/Terminating Station Telephone Number The terminating telephone number. Indicates the transmission speed for the circuit. TF Trunk Group Number Identifying number for a group of trunks. Indicates whether the circuit is to be designed for one way or two way transmission. TE Coding Describes the method used on a high speed digital circuit to encode the stream of bits to ensure the proper bit density and proper transmission synchronization between the transmitting and receiving stations. Identifies unique Dialing Plan for some services arrangements. The telephone number(s) to which the calls to an intercepted telephone number are to be referred. TD DESCRIPTION of DE1000 Code Telephone Number For Billing purposes, the line number or network address associated with billable charges. Framing For Ordering purposes, the line number or range of numbers associated with a main account Describes the technique to be used on a high speed digital communication circuit to define the start and end of each single frame of transmitted information as well as the internal structure of that frame. TO Service Center DA Listings 61 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Identifies the provider’s service center for processing Directory Assistance (DA) listings. TP TQ TT Identifies the type of transport for the usage charges. Identifies the appropriate Service Center in a telecommunications company which is to receive this request. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Telephone Line Identifier TU Service Center Directory Listings Identifies the provider’s service center for processing directory listings. Transport Tariff TV A locally defined tariff. TS Transport Type Telecommunications Provider Office To identify the pilot number in a multiline hunt group. TR DESCRIPTION of DE1000 Code TTY or TDD Indicator An OBF value that identifies that Service Equipment or Directory Listings should have a special TTY or TDD phrase included. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). Type of Signaling Identifies lines and trunks that require specific central office equipment. OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. TW Style Code An OBF value that identifies whether the listing is a straight line, caption header, etc. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). EGCS Valid DE234 values: ARL Two Point Automatic Ringdown Signaling Arrangements Loop Closure DST Delayed Dial Start EMS E&M Signaling Interface EM1 E+M1 EM2 E+M2 EM3 E+M3 IST Immediate Start GST Ground Start LPS Loop Signaling LRB Loop Reverse Battery LST Loop Start SAC Manual Signaling Arrangement with Code Selection for Multipoint Service SAH Manual Signaling Arrangement for Two-Point or Multipoint Services 20 Hertz Interface SRA Signal Range Extension-Type A SRB Signal Range Extension-Type B SRC Signal Range Extension-Type C SRE Signal Range Extension VST Virtual Start WST Wink Start TX Translated Telephone Number The translated telephone number associated with a Dialed Telephone number when different than the To/Terminating Number, e.g. the working telephone number for an 800 call. TY Type of Service An OBF value which identifies the type of service for the line ordered. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). TZ Telephone Line Identifier Type An OBF value which identifies the type of Telephone Line Identifier. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering 62 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Guidelines (LSOG). T0 -- Telephone Number Type T7 An OBF value which identifies the type of telephone number being requested. For a list of Valid Values used with this code see the current issue of OBF Local Service Ordering Guidelines (LSOG). T1 T8 DID Telephone Number Range Identifies the range of DID telephone numbers within the same switch where a dash (-) is used to express the range, e.g. 2035221200-1259. Telephone Service – Boards UA Apportioned Minutes of Use (MOU) Type Telephone Service – Jack A code which denotes the type of Minutes of Use used in an apportionment calculation. Identifies the specific lines/trunks that are to be wired to the Telephone Service/ Connection Information for jacks. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Telephone Service – Forwarding Number UB Identifies the telephone number on which a jack physically works when the jack also physically works on the account on which this request is written. It is the number at the Telephone Bureau to which calls are forwarded. T5 Transfer Call to Secondary Number Telephone Service – Position Identifies the specific lines/trunks that are to be wired to the Telephone Service/ Connection Information for boards. T4 Jack Number Identifies a secondary number to which calls can also be transferred to. T9 T3 Code provided by Trading Partner Number used to identify a jack. Identifies the specific line/trunks that are to be wired to the Telephone Service/ Connection information for position. T2 DESCRIPTION of DE1000 Code Class of Service (USOC) Indicator A code used to identify the type of USOC presented in customer service record information. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Terminal Number UC Class of Service (USOC) Number used to identify a Terminal. T6 A service provider defined code that identifies the class of service for a dedicated or switched circuit (or group of circuits). Transfer of Calls Options A code to identify the type of calls options requested by the end user. UG OBF maintains the list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. USOC Billing Group Identifies a grouping of USOCs, or other service codes, across customer locations. The grouping may be used to identify USOCs that are eligible for a special rate and/or discount. EGCS Valid DE234 values: N None S Standard T Split Transfer of Calls UK Trunk Type 63 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Identifies the type of trunk. The percent of local usage for determination of the local access service charges for a particular USOC. OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. UL U2 Universal Life Line Designator U3 OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. Percent Local Usage U4 U5 For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Percent Proportional Usage. The percent of monthly recurring charges to be billed to the CLEC for utilization of two-way trunks for local usage. Unbundled Tariff Indicator VC A code which denotes that the applicable rates are from the unbundled tariff. UU USOC Specific Percent Intrastate/intraLATA Usage The percent of intrastate/intraLATA usage for determination of the intrastate/intraLATA versus intrastate/interLATA access service charges for a particular USOC. PIU Source Indicator. A code which denotes the source of the PIU used when actual data is not available. UT USOC Specific Percent Interstate/interLATA Usage The percent of interstate/interLATA usage for determination of the interstate/interLATA versus interstate/intraLATA access service charges for a particular USOC. The percent of usage for determination of the access service charges associated with CABS billing. US USOC Specific Percent Intrastate/InterLATA Usage The percent of intrastate/interLATA usage for determination of the intrastate/interLATA versus intrastate/intraLATA access service charges for a particular USOC. Indicates whether the residential resale line is the Primary Line or a Non-Primary line at the same address for the purpose of tracking Universal Life-Line qualification. UP DESCRIPTION of DE1000 Code Identifies the logical connection address between the provider's switch and the circuit for the virtual circuit requested. For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values. Unbundled Usage Indicator VK VM Cut Type U1 A locally defined code that identifies the type of Batch Hot Cut being performed. USOC Specific Percent Local Usage Virtual Connection Identifier Identifies the address of a virtual connection. Identifies the minutes of use originating from or terminating to an unbundled port. UY Virtual Circuit Identifier Voice Mailbox Mailbox access billing categories for access methods. Valid DE234 values: UA User Access 64 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CA CODE WN VI Virtual Path Identifier For Ordering purposes, identifies the logical connection address for the virtual path requested. For Billing purposes, identifies the address of a virtual path. VP WS Special Identifying Telephone Number Supplement (SIS) code used to identify individual 800 service lines. WT Working Telephone Number Identifies the End User’s Working Telephone Number at a specific location. W1 Working Telephone Number Status Variable Rate Code A locally-defined code that identifies the status of the working telephone number. Identifies that a variable rate applies to the billed item. XA Call Detail Indicator Voice Traffic Surcharge Exempt Reason Identifies disposition of a Call Detail Record. Identifies the applicability of the leakage surcharge for each location on a circuit carrying voice traffic. Valid DE234 values: 8 Billed by Other Entity 9 Previously Sent Valid DE234 values: A Surcharge Applies and should be Billed B Customer has a blanket exemption certificate filed with the local exchange company E Customer certifies that the service terminates on a device which prohibits the interconnection of the service with the local exchange carrier and the circuit is exempt from the surcharge N Surcharge does not apply to this circuit WC Wide Area Telephone Service (WATS)SIS Code Virtual Path Indicator OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. VT Wide Area Telephone Service (WATS) Line Number SIT Code The WATS or 800 service access line number for which service is rendered. Identifies the logical connection location and quality of service for the virtual path requested. VR DESCRIPTION of DE1000 Code Outside Caller Access XC NCP – ID Identifies a number that is set up in the NCP to verify a customer exists for intelligent services. XE Call Abandoned Indicator Identifies calls abandoned by the originator. Valid DE234 values: 1 Abandoned Call Wire Count Option XR Number of wires to be utilized in the provisioning of the service. Cross Reference Code of Circuit Location/Drop to Bridging Location Code identifying the circuit location or drop at the bridging location. Valid DE234 values: 2 Two Wire 4 Four Wire 8 Eight Wire YP Feature Query Type 65 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION CODE INDUSTRY CONVENTIONS ASC X12 Version 004050 DESCRIPTION of DE1000 Code CODE Identifies the query type selected. Z1 Valid entries for IN203: TITLE1 Title of Address 1 TITLE1D Title of Address of 1 for Dual Name listing OBF maintains a list of valid values that may be used with this field. See Local Service Ordering Guidelines (LSOG) for a list of these valid values. . Mutually Defined (See Note 1 in Appendix A) Z2 Mutually Defined (See Note 1 in Appendix A) Z3 Mutually Defined (See Note 1 in Appendix A) Z4 Mutually Defined (See Note 1 in Appendix A) Z5 Mutually Defined (See Note 1 in Appendix A) Z6 Mutually Defined (See Note 1 in Appendix A) DESCRIPTION of DE1104 Code 09 Suffix Valid entries for IN203: TITLE2 Title of Address 2 TITLE2D Title of Address of 2 for Dual Name listing 10 Generation Valid entries for IN203: TL Title of Lineage TLD Title of Lineage for Dual Name listing 1270 Code List Qualifier Code TYPE=ID MIN=1 MAX=3 Code identifying a specific Industry code list. Z7 Mutually Defined (See Note 1 in Appendix A) Z8 Mutually Defined (See Note 1 in Appendix A) Z9 Mutually Defined (See Note 1 in Appendix A) 1271 Industry Code 99 Continuation Code TYPE=AN MIN=1 MAX=30 Code indicating a code from a specific Industry code list. Used only when preceding DE234 exceeds maximum length of field. Report Purpose Code NOTE: This codelist should not be used with ELMS5 and later. Type=ID Min=2 Max=2 Code identifying the type of name component CODE A EGCS Maintained Code Values for IN2 Segment. B C D E Phrase Code values to be used in the IN2 segment in IN203, DE93, are OBF Field Identification (FID) codes and help to delineate between otherwise identically qualified IN2 segments. 01 DESCRIPTION of DE1270 Code HC PRE-ADDRESS – Pre-ordering Address Response Code List 1104 Name Component Qualifier CODE CODE DESCRIPTION of DE1271 Code Found (with actual entry of database)/match Not found/no match Alternates exist/near match Restricted/Government Additional building and floor PRE-FRESP - Pre-ordering Feature/Service Response Code List DESCRIPTION of DE1104 Code Prefix 66 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 NOTE: This code list should not be used with ELMS5 and later. CODE A B G N P Y DESCRIPTION of DE1271 Code Alternate NPA-NXX available Product available may require special handling Grandfathered Not available Pending Yes CODE DEFINITION of DE1301 Code DP DSC DV1 DV2 DV3 EEH EXP FUR GRD MAE MTL Disabled Person Discount Discount Diversity – Central Office Diversity – Local Loop Diversity – Total Circuit Engineering Charge Expedited Service Charge Feature Unit Rate Groupage Discount Monthly Rental Installation Material For a list of Valid Values used with this code in SAC13 see the current issue of OBF Local Service Ordering Guidelines (LSOG). Overtime Loading Optional Payment Discount Promotional Discount Percentage Pricing Contract Plan Promotion Discount Quantity Discount Rate Code This is used to specify that SAC08 contains the contracted annuity factor Rate Stability Plan Special Assembly Charge Service Charge Time Indicator For a list of Valid Values used with this code in SAC13 see the current issue of OBF Local Service Ordering Guidelines (LSOG). Termination Liability Charge Volume Discount Volume Pricing Plan Variable Term Contract Pricing Plan QR3 – HC - Chart Type CODE CC CU MR NP PP QM RR UU XX DESCRIPTION of DE1271 Code C Chart CUMSUM Chart Moving Range Chart NP Chart P Chart QMP Chart R Chart U Chart X-Bar Chart OAC OP PAI PP PR QQD RTC RS SA SER TIND 1301 Agency Service, Promotion, Allowance, or Charge Code TYPE=AN MIN=1 MAX=10 Agency maintained code identifying the services, promotion, allowance, or charge. TL VAB VP VT EGCS MAINTAINED CODE VALUES CODE DEFINITION of DE1301 Code 1 275 295 350 2T ADV Type 1 Billing Discount Incentive Discount Special Expedited Shipments Two Tier Pricing Contract Advances This is used to indicate an Advanced Payment Administrative Overhead Percentage Avoidance – Geographic Area Avoidance – Purchase Order Avoidance – Total Circuit CENTREX Line Capacity Contract Customer Calling Discounts Connect Charge CENTREX Service Transport Facility Contract Contract/Tariff Plan AO AV1 AV2 AV3 CC CD COC CP CT 67 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix A Notes Note 1: This code is to be used only temporarily to meet mandated changes. A request for a new code should be completed within 90 days. Note 2: This code is not valid when used with ASC X12 Release 3030 or higher. Note 3: These codes are only valid with ASC X12 Release 3040 or higher. Note 4: These codes are not valid with ASC X12 Release 3040 or higher. Note 5: These codes are only valid with ASC X12 Release 3050 or higher. Note 6: These codes are not valid with ASC X12 Release 3050 or higher. Note 7: These codes are not valid with ASC X12 Release 4010 or higher. Note 8: These codes are only valid with ASC X12 Release 4010 or higher. Note 9: These codes are only valid with ASC X12 Release 4020 or higher. Note 10: The three character codes for 1000 Service Characteristics Qualifiers are only valid with ASC X12 Release 4050 or higher. 68 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix B Pseudo CICs AT&T I288 00IL 00IN 00MI 00OH 00WI 00AR 00KS 00MO 00OK 00TX 00CA 00NV 00LD 00AM 0SN0 0SS0 - AT&T Invoice Billing AT&T Illinois AT&T Indiana AT&T Michigan AT&T Ohio AT&T Wisconsin AT&T Arkansas AT&T Kansas AT&T Missouri AT&T Oklahoma AT&T Texas AT&T California AT&T Nevada AT&T Long Distance AT&T Messaging AT&T Connecticut AT&T Diversified Group Cincinnati Bell 00CB - Cincinnati Bell MCI I222 - MCI Invoice Billing – formerly Worldcom Qwest 0C00 0W00 0E00 - Qwest Central Qwest Western Qwest Eastern SBC SBC SBCI SBCT SBCIL SBCIN SBCM SBCMI SBCOH SBCWI SBCAR SBCKS SBCMO SBCOK SBCTX SBCCA SBCNV SBCLD - SBC SBC Internet Services SBC Telecom SBC Illinois SBC Indiana SBC Messaging SBC Michigan SBC Ohio SBC Wisconsin SBC Arkansas SBC Kansas SBC Missouri SBC Oklahoma SBC Texas SBC California SBC Nevada SBC Long Distance Southwestern Bell Tel. SWBT - Southwestern Bell Telephone Sprint I333 - Sprint Invoice Billing Sprint LTD 0141 0142 0209 - New Jersey Telephone Company United Telephone Company of New Jersey United Telephone Company of Pennsylvania 69 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix B Pseudo CICs Verizon Communications Inc. 0341 0470 0506 0567 0661 0832 0203 1317 1456 1595 1728 1842 1957 2084 2400 - United Telephone Company of Florida Carolina Telephone and Telegraph Company United Telephone Company of the Carolinas United Inter-Mountain Telephone Company United Telephone Company of Ohio United Telephone Company of Indiana, Inc. United Telephone Eastern Group United Telephone Company of Iowa United Telephone Company of Minnesota United Telephone Company of the West United Telephone Company of Arkansas United Telephone Company of Kansas United Telephone Company of Missouri United Telephone Company of Texas United Telephone Company of the Northwest 00NJ 0CPV 0CPW - 0CPM 0CPD - 00BP 00DS 0698 09X0 0A11 CONT GTET - Verizon - formerly New Jersey Bell Verizon - formerly Chesapeake & Potomac of Virginia Verizon - formerly Chesapeake & Potomac of West Virginia Verizon - formerly Chesapeake & Potomac of Maryland Verizon formerly Chesapeake & Potomac of District of Columbia Verizon - formerly Bell of Pennsylvania Verizon - formerly Diamond State Verizon - formerly New York Telephone Verizon - formerly New England Telephone Verizon - formerly Southern Bell Verizon - formerly Contel of California Verizon - formerly GTE Telephone Operations 70 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix C Feature Code List SF CODE 3WC 3WC002 3WC003 AAC001 AAC002 AAC003 AAC004 ACJ ACR001 ACR002 ACR003 ACR004 ACR005 ACR006 ADL ARS001 ARS002 ARS003 ARS004 ARS005 ARS006 ARS007 CCG001 CCG002 CCG003 CFW001* CFW002* CFW003* CFW004* CFW005* CFW006* CFW007* CFW008* CFW009* CFW010* CFW011* CFW012* CFW013* CFW014* CFW015* CFW016* Description 3-Way Calling 3 Way Calling – Restricted to United States 3 Way Calling-with International Access Account and Access Codes Account Codes – Per Line Account Codes – Per System Authorization Codes – Per Line Authorization Codes – Per System Anonymous Call Rejection Automatic Call Return Automatic Call Back Automatic Recall Last Call Redial Continuous Redial Automatic Recall – Last Call Return Automatic Recall – Per Number Additional Line Automatic Route Selection Change of Schedule Changes/Rearrangement Common Equipment Expensive Route Warning Tone Facility Restriction Level Time of Day Control Time of Day Routing Conference Calling 6 Way Meet Me Preset Call Forward Busy Don’t Answer Busy Line Busy Line – All Calls Busy Line – Cust Actvn, Dactvn & Change Cpblty; Programmable Busy Line – Data Busy Line – Don’t Ans Busy Line – Don’t Ans – Sta Actvn, Dactvn & Chg Cpblty Busy Line – Don’t Ans – Unrestricted Source Busy Line – Incoming Calls Busy Line – Incoming Only – Data Busy Line – Inhibit Line Busy Busy Line – Inhibit Make Busy Busy Overflow By Calling Number – Day of Year Routing By Calling Number – Time of Day/Day of Week Routing Call Forwarding Number 71 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix C Feature Code List SF CODE CFW017* CFW018* CFW019* CFW020* CFW021* CFW022* CFW023* CFW024* CFW025* CFW026* CFW027* CFW028* CFW029* CFW030* CFW031* CFW032* CFW033* CFW034* CFW035* CFW037* CFW038* CFW039* CFW040* CFW041* CFW042* CFW043 CHD001 CHD002 CHD003 CID001 CID002 CID003 CID004 CID005 CID006 CID007 CID008 CID009 CID010 CID011 CID012 CID013 CID014 CID015 CID016 Description Call Waiting Calls Calling Number Customer Programmable Call Forward Busy Customer Programmable Call Forward Don’t Answer Don’t Answer All Calls Don’t Answer Call Forward Busy – Per Line Don’t Answer Call Forward Busy – Per System Don’t Answer – Customer Activation, Deactivation & Change Capblty; Programmable Don’t Answer – Incoming Calls Don’t Answer – Incoming Calls – Data Don’t Answer – Intra-office Don’t Answer – Unrestricted Source Over Private Facilities Over Private Facilities – Per Line Over Private Facilities – Per System Over Private Facilities – Reminder Ring Option Over Private Facilities – Reminder Ring Option Inhibited Per Key Per Set Remote Activation, Deactivation & Change Capability Time of Day/Day of Week Variable Variable – Don’t Answer Variable – Don’t Answer – Intercom Line Only Variable – Per Console; Attendant Programming Variable – Reminder Ring Option Inhibited Delay Call Forwarding Call Handling & Distribution 800 Service; Alternate Call Routing 800 Service; Emergency Updates Activate or Deactivate Call Hold Caller Identification (ID) Call Waiting Display Calling Name Display Calling Name Display – Blocking Calling Name Display – Selective Blocking Calling Name & Number Delivery Calling Name & Number Delivery – Anonymous Caller Rejection Calling Name & Number Delivery – Blocking Calling Name & Number Delivery – Caller Identification Calling Name & Number Delivery – Selective Blocking Calling Number Delivery Calling Number Delivery – Blocking Calling Number Delivery – Caller ID # Only Calling Number Delivery – Selective Blocking Dialable Calling Name & Number Delivery Dialable Calling Number Delivery Display Application 72 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix C Feature Code List SF CODE CID017 CID018 CID019 CID020 CID021 CMS001 CMS002 CMS003 CMS004 CMS005 CMS007 CMS008 CMS006 CPK CPU001 CPU002 CPU003 CPU004 CPU005 CRD CSC001 CSC002 CSC003 CSC004 CSC005 CTX* CWG001 CWG002 CWG003 CWG004 CWG005 CWG006 CWG007 CWG008 CWG009 CWG010 CWG011 CWG012 CWG013 DCP* DIA* DID001* Description Management Info System Package – Per Display Application Software Feature – Custom Roll Over From Display Application to Switch Application Software Feature – Interface additional 800 Service Numbers – Per No Arranged Switch Application Selective Call Management for Anonymous, Private or Unidentified Calls Centron/CENTREX Management System Bulk Change Custom Reports Initial Installation Network Manipulation Packet Control Capability Subsequent Installation System Partitioning Priority Service Call Park Call Pickup Basic Call Hold Pickup Group Directed Call Pickup Barge-In Directed Call Pickup Non-Barge-In Call Related Database Selective Call Acceptance Distinctive Alert Forwarding Rejection International Call Alert Call Transfer Call Waiting Cancel Call Waiting; No Double Connect Dial Dial Originating Indication Originated Originating Terminating Calls Terminating Incoming Calls Camp-On & Call Waiting – Originating Music Option Camp-on & Call Waiting – Originating Recorded Announcement Option Camp-on & Call Waiting – Originating Silence Option Call Waiting Identification (ID) Call Waiting ID Options Data Call Protection (DM-100) Direct Inward Access Code DID 73 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix C Feature Code List SF CODE DRG001 DRG003 DRG004 DRG002 EBO EAS* ESI* FEX* HTY001 HTY002 HTY003 HTY004 HTY005 HTY006 HTY007 HTY008 HTY009 HTY010 ICM* ICM001 KBA LSP001 LSP002 MBY001 MBY002 MOH* MWG001 MWG002 MWG003 MWG004 MWG005 NSA* OCP RCF001* RCF002* RCY001* RDC RTI001* RUD SBL Description Distinctive Ringing Distinctive Ringing & Call Waiting Tone – Class B Tone Distinctive Ringing – Centron 1, Call Waiting; Priority Call Per Line Distinctive Ringing/Distinctive Call Waiting Tone Distinctive Ringing & Call Waiting Tone – Class C Tone Executive Busy Override Extended Area Service Unlimited Calling Electronic Set Interface – Per Line Foreign Exchange Hunting Circular Sequence – Non-Multiline Group Hunting Groups Multi Line Hunting Multiple Position Hunt Per Group Multiple Position Hunt Per Line Multiple Position Hunt Queuing Per Group Non-Hunting Number Preferential Hunting Combination (CENTREX) Intercom Feature Intercom Plus Key/Button Programming Assignment Loudspeaker Paging Per Attendant Access Per Console Per Trunk Group Make Busy Arrangement Arrangement Key Controller Music On Hold Message Waiting Audible Message Waiting Message Center Message Waiting Indication Message Waiting Visual Executive Message Waiting Night Service Arrangement Optional Calling Plan Remote Call Forwarding Call Forwarding Number Ring Cycle Ring Cycle Resale Direct Connection Route Index Resale Usage Discount Station Busy Lamp Speed Calling 74 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix C Feature Code List SF CODE SCG001 SCG002 SCG003 SCG004 SCG005 SCG006 SCG007 SCG008 SCG009 SCG010 SCG011 SCG012 SCG013 SCG014 SCG015 SCG016 SCG017 SCG018 SCG019 SCG020 SCG021 SCO001 SCO002 SMD001 SMD002 TDR001 TDR002 TTN UCD001 UCD002* UCD003 UCD004 VAD VMS001 VMS002 VMS003* VMS004 VMS005 VMS006 VMS007 VMS008 VMS009 Description 1 Digit Controller 1 Digit User 1 # List Individual 1000 Code 2 Digit Controller 2 Digit User 2 # List Individual 30 Code – Customer Changeable 30 Numbers 50 Code – Customer Changeable 6 Code 6 Code – Customer Changeable 70 Code – Customer Changeable 8 Code – Customer Changeable Change in Repertories Change Speed Calling Group List Network Speed Call Pause Insertion – Per System Share Speed Call List One Share Speed Call List Two Up to 10 Code Capacity Station Camp On Per Line Service Establishment Station Message Detail Recording Call Detail Per Line Time of Day Routing Per Line Update Touch Tone Uniform Call Distribution Delay Announcement Hunt Group Music After Delay Silence After Delay Announcement Trunk Voice Activated Dialing (Dial Dictation) Voice Message Service Call Answering Service Call Routing Service Call Routing to Number Contributor Mailbox Extension Mailbox Listen Only Mailbox Message Notification Message Send Scheduled Greetings 75 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Appendix C Feature Code List SF CODE VMS010 VMS011 VMS012* VMS013* VMS014 VMS015 VMS016 VMS017* VMS018 VMS019 VMS020 VMS021 VMS022 VMS023 VMS024 VMS025 WAT001* WAT002* WAT003 WAT004 WAT005 WAT006 WAT007* WAT008 WAT009 WAT010 WAT011 WAT012 WAT013 WAT014 WAT015 WAT016 WML Description Transfer Mail Box Voice Mail Voice Mailbox – With Call Forwarding – Busy Line Voice Mailbox – With Call Forwarding – Busy Line – Don’t Answer, Message Waiting Audio & Visual Indicator Voice Mail Box Guest Mail Box Return to Operator Digital Pager Option Voice Pager Option Daily Reminder Voice Calendar or Reminder Message Delivery Options Urgent Message Delivery Language Prompts Message Waiting Indicator Open Network Architecture (ONA) Voice Mail – Call Forward Busy WATS Service Area Code Routing Area of Service Bulk Calling Call Allocator Call Attempt Data Reports Call Prompter Courtesy Routing Emergency Routing Exchange Routing Mass Calling On-line Call Detail Overflow Routing Referral Service Routing Control Service Single 800 Number Time of Day Routing Warm Line Feature Additional Feature Data required for these “SF” codes using the “FD” code in the next pair. 76 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Summary of Revisions 11/06 Revisions from November Meeting in Sacramento, CA Added new DE751 codes: “FE – Facility Environment”, “FEP – Facility Environment Provisioned”, “FSQ – Fiber Service Qualification”, “DD – Fiber Capability Indicator” Added new DE1000 code: “IF – Installation/Disconnect Code”. Added new DE234 codes for SIDE1000 code “IF”: “I – Installation”, “D – Disconnect”, “B – Both Install and Disconnect” 06/08 Revisions from June Meeting in Savannah, GA Corrected link name on page 10.4-5 from www.necaservices.com to www.neca.org 03/06 Revisions from March Meeting (Virtual Meeting) Updated description for DE 66 value 91 related to Telephone Billing applications Add EDI billing Pseudo CIC for AT&T Messaging Add EDI billing Pseudo CIC for AT&T Long Distance Remove EDI billing Pseudo CIC information related to Ameritech, Pacific Bell, and SNET Add EDI billing Pseudo CIC's for AT&T Illinois, AT&T Indiana, AT&T Michigan, AT&T Ohio, AT&T Wisconsin, AT&T California, AT&T Nevada, AT&T Arkansas, AT&T Kansas, AT&T Texas, AT&T Oklahoma, AT&T Missouri Add EDI billing Pseudo CIC's for AT&T Connecticut and AT&T Diversified Group 11/05 Revisions from November Meeting (Virtual Meeting) Updated DE128 code “82” to add associated phrase code “ORCD” Added new DE352 code for DE128 value “IX”: “PONLEREFNUM” Added new DE369 code “LRNUM” for DE128 value “IX”: Added new DE369 code “LRC” for DE128 value “82”: Added new DE369 code “ERRCODE” for DE128 value “1Q”: Added new DE1000 codes “CPG”, “SPG”, “DOS” 05/05 Revisions from May Meeting in Denver, CO Added new Pseudo-CIC code “SBCLD” – SBC Long Distance Added new DE234 code “36” (North America) to DE1000 code “DA” 02/05 Revisions from February Meeting in Long Beach, CA Added new DE128 code “MZ” Added new DE234 value “0315” under DE235 code “SV” 77 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Added new DE1000 codes “CHC”, “CMA”, “SVC” 10/04 Revisions from October Meeting in Las Vegas, NV Updated description of DE234 code “C” under DE1000 code “OC” (remove “partial month”) 09/04 Revisions from September Meeting (Virtual Meeting) Added DE1000 code “EUA” 03/04 Revisions from March Meeting (Virtual Meeting) Added new DE751 codes “BCOPT”, “CZ”, “ISR” Added new DE1000 codes “DRT”, “UY” 02/04 Revisions from February Meeting in Charlotte, NC. Corrected URL for DE66 Identification Code Qualifier of 91 12/03 Revisions from September Meeting in Birmingham, AL. Renamed Pseudo-CIC codes under “Worldcom” to “MCI” 09/03 Revisions from September Meeting in Denver, CO Added new DE751 codes: “LTNE – Listing Telephone Number Environment” Modified DE1000 code: “IQ” to “An OBF value which identifies the type of transaction.” Modified DE1000 code: “IR” to “An OBF value which identifies the transaction activity.” Renamed Pseudo-CIC codes under “Bell Atlantic and GTE” to “Verizon Communications Inc. 06/03 Revisions from June Meeting in Seattle, WA Updated DE128 code “DISPNOTES” description to add “or log”. The description now reads - “Dispatch or log information associated with the service order”. Added new DE751 codes: “TAI – Transaction Activity Indicator”, “MLT – Mechanized Line Test”, “CX – Re-Qualification”, “CY – Switch Supported” Modified DE751 phrase code: “LSA”, added description after the element name Added new DE1000 codes: “MAC”, “S6”, “VK” Modified DE1000 code: “VI” to add a billing purpose to the definition Added the following Pseudo-CIC codes under “SBC”: “SBCM – SBC Messaging” 03/03 Revisions from March Meeting in St. Louis, MO Updated DE128 code “V0” to add associated phrase code “PONVER”. Added new DE751 codes: “CO”, “CP”, “CQ”, “CR”, “CS”, “CT”, “CU”, “CV”, “CW”, “DA”, “DC”, “ACCTDES”, “ASGTRSTN”, ”CFAST” 78 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Updated definition for existing DE751 phrase code: “QRYIND” Added New DE234 codes to existing DE1000 code “CH”: “08”, “09” Added new DE1000 Codes: “EC”, “FQ”, “R6” Added the following Pseudo-CIC codes under “SBC”: “SBCIL”, “SBCIN”, “SBCMI”, “SBCOH”, “SBCWI”, “SBCAR”, “SBCKS”, “SBCMO”, “SBCOK”, “SBCTX”, “SBCCA”, “SBCNV”. 11/02 Revisions from December Meeting in St. Louis, MO/Hoffman Estates, IL Updated DE128 code “OW” to add associated phrase codes “CS01” and “CS02”. Added new DE751 codes: “CM”, “CN”, “PGPRES” Added New DE234 code to existing DE1000 code “MT”: “AL” Added New DE234 code to existing DE1000 code “QT”: “PL” Added New DE234 code to existing DE1000 code “ST”: “BR” Added new DE1000 Code: “QC” Added “SBCI” – SBC Internet Services to Appendix B – Pseudo-CIC. Modified Column Headers for “Description” to include the Date Element number being described. 09/02 Revisions from September Meeting in Las Vegas, NV Updated DE128 code “11” to add associated phrase codes “AAN”, “NAN”, “NATN”. Updated DE128 code “OW” to add associated phrase code “BOPI”. Added DE128 code “V0” and associated phrase code “BULKVER” Added new DE751 codes: “BSVC”, “CH”, “CI”, “CJ”, “CK”, “CL”, “DAT”, “ITYP”, “PCT”, “PPT”, “RP”, “TA”, “TTYP” Added New DE234 codes to existing DE1000 code “QT”: “MAXB”, “MDPK”, “MTER” Added New DE234 codes to existing DE1000 code “SD”: “IEM”, “IY”, “IYN”, “IYS” Updated verbiage for existing code “1610” under existing DE235 code “SV” Added new DE1000 Codes: “0P”, “3P”, “4P”, “8P”, “8V”, “A0”, “A1”, “A2”, “BW”, “BZ”, “C0”, “C7”, “C8”, “C9”, “CZ”, “EK”, “FW”, “FY”, “GC”, “GR”, “GS”, “ID”, “IE”, “IV”, “KG”, “L8”, “LV”, “LW”, “MF”, “MN”, “MQ”, “MW”, “MY”, “MZ”, “N1”, “N2”, “N3”, “NE”, “NG”, “NK”, “OM”, “QM”, “R2”, “R5”, “UU” Added standard DE234 Verbiage “For CABS billing applications, see current issue of CABS BOS Specifications for a list of valid values” to existing DE1000 codes: “BA”, “RP” 06/02 Revisions from June Meeting in Fairfax, VA Updated DE128 code “82” to add associated phrase code “CODEDES” 79 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Added new DE751 codes: “CG”, “PROJIND”, “TNE” Added new DE234 codes to existing DE1000 code “DC”: “LM”, “ML”, “MM” Added new DE234 codes to existing DE1000 code “SD”: “IAMA”, “IAME”, “IEMA”, “IEME” Added new DE234 codes to existing DE1000 code “ST”: “PP” Added new DE1000 codes: “CW”, “C6”, “FO”, “KB”, “VI” Updated existing definitions for DE1000 codes: “HY”, “VC”, “VP” Added new code for DE1301: “FUR” Changed “MCI” to “Worldcom” in Appendix B for I222 03/02 Revisions from March Meeting in St. Louis, MO Added new values to DE150 code list: “CRS”, “DDF” Added new DE234 codes to existing DE1000 code “AR”: “SOACT” Added new DE234 codes to existing DE1000 code “AS”: “F” Added new DE234 codes to existing DE1000 code “QT”: “TST” Added new DE234 codes to existing DE1000 code “ST”: “E911” Added new DE352 code for DE128 value “2I”: “VSRNO” Added new DE352 codes for DE128 value “12”: “BAN”, “VAN” Added new value to DE560 code list: “NREG” Added new DE751 codes: “POTSSPLITLOC” , “TNT” Added new DE1000 codes: “AR”, “EJ”, “EZ”, “KA”, “KF”, “KL”, “KP”, “KR”, “KT”, “LJ”,”S5”, “UB”, “UT”, “W1” Changed all references to US West in Appendix B to Qwest. 12/01 Revisions from December Meeting in Tampa, FL Add new DE234 codes to for 235 value “SV”: “0305”, “1250” Added new DE234 code to existing DE1000 code “DA”: “35” Added new DE234 codes to existing DE1000 code “QT”: “CCH”, “NR”, “RPL”, “SBCH”, “SC”, “SUCH”, “TCCH”, “TCH”, “VPL” Added new DE560 code: “CMPLX” Added new DE751 codes: “ASGNIND”, “EXP”, “QRYIND” 80 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Added new DE1000 codes: “1P”, “2P”, “FX”,”AZ”,”GT”, “K9”,”RK”, “R0”,”S1”, “S2” 09/01 Revisions from September Meeting in Reno, NV Added new DE150 codes: “LPA”, “LPP” Added new DE560 codes: “CPB”, “CPL”, “CPO”, “DSP”, “ND”, “PB”, “SVO” Added new DE751 codes: “BAI”, “BX”, “BY”, “BZ”, “CA”, “CB”, “CD”, “CE”, “CF”, “LLT”, “LM”, “MEU”, “NCDEF”, “RTF”, “SSC”, “STATUS” Added new DE1000 codes: “BI”, “CY”, “D0”, “EO”, “FB”, “GL”, “IG”, “IS”, “K0”, “L4”, “L5”, “L6”, “L7”, “LK”, “LQ”, “LY”, “MJ”, “MO”, “MR”, “NY”, “OE”, “OW”, “R1”, “R3”, “R4”, “S4”, “UK”. Updated DE128 code “82” to add associated phrase code “DCGMU”; code “IX” to add associated phrase code “RNUM”. Added valid values to DE235 code “SV”: 2600 – CABS Late Payment Charges Added valid values to DE1000 code “OC”: D15 – Equipment, H22 – Tax; to code “QT”: F1DQ - , F2DQ - , REPTRQTY - ; to code “SP”: CP – Commitment Plan Applies Updated DE1000 code “AD” to remove reference to “Directory Service Request” in the descriptive definition; updated code “DY” to modify the description. Added “SBC” – SBC, and “SNET” – SNET to Appendix B – Pseudo-CIC. 06/01 Revisions from June Meeting in Rancho Mirage, CA Updated DE128 code “82” to add associated phrase code “SOSTATDES”. Updated DE128 code “IX” to add associated phrase code “LEGNUM”. Updated DE128 code “OW” to add associated phrase codes “ORDL”, “SON”. Added new DE751 codes: “BU” and “BV”. Added new DE1000 codes: “AJ” – Primary Interexchange Carrier Apportionment Factor, “AK” – ACNA/State Indicator, “AO” – Provisioning Activity/Status, “D9” – Disability Indicator, “F1” – Facility Designation, “F2” – Facility Type, “F3” – Location A, “F4” – Location Z, “FL” – Foreign Language Indicator, “HG” – Hunt Group Code, “MV” – Minutes of Use (MOU) type (with associated DE234 values), “NF” – Notification Type, “NW” – New construction, “OF” – Retrieve Orders, “OO” – Outgoing Only Service Code (OGO), “QD” – Quick Dial Tone Number, “RY” – Local/Toll indicator (with associated DE234 values), “UA” – Apportioned Minutes of Use (MOU) Type. Added valid values to DE1000 code “ST”: 211 – Information Referral, 311 – Non Emergency, 511 – Transportation Information. 03/01 Revisions from March Meeting in Haines City, FL Added DE66 code “91” and related code source for OCN (TBWG’s use of this qualifier). Updated DE128 code “82” to add associated phrase codes for DE127 (N902): 81 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 “APPTINFO”, “DISPNOTES”, “MSDAPT”, “SODETAIL”. Updated DE128 code “1Q” to add associated phrase codes for DE369 (N903): “PRESPC” and “RESPC”. Updated DE235 code “A6” to add associated phrase codes for DE234: “CKT”, “DDA”, “DID”, “UNI”. Updated DE235 code “SV” to removed note from associated DE234 value “1750” . Added new DE560 codes: “ER” – Interstate/IntraLATA, “RR” – Intrastate/IntraLATA, “TOL” – Toll. Added new DE751 codes: “FEATDES”, “BT”. Updated DE751 code “BP” with a note sunsetting the valid values. Added new DE1000 codes: “AH” – Primary Interexchange Carrier Apportionment ID (w/ 3 valid values), “CV” – Cable Type Indicator, “DW” – Detect Number, “D8” – Distinctive Ring Telephone Number, “K8” – Slot Port, “L3” – Local Calling Scope, “MG” – Migration Indicator, “MU” – Daily Workload for Maintenance Center, “NB” – Nearby Telephone Number, “NH” – Telephone Number Change, “U5” – Percent Proportional Usage, “SV” – Service Configuration, “S3” – Status of Service Order, “YP” – Feature Query Type. Added “SBCT” – SBC Telecom, to Appendix B – Pseudo-CIC. 12/00 Revisions from December Meeting in Nashville, TN Added code “4L” to DE128 with code source information. Updated descriptive information for DE128 code “LU” to differentiate between the uses for CABS BOS and LSOG applications. Added new DE150 code “PCR” – Performance Credit. Added valid values to DE1000 code “DA”: “33” – 555 Business Listing, “34” – 411 Business Listing”. Added valid value note to DE1000 codes “SA”, “DS”: “For CABS billing applications, see the current issue of OBF’s CABS BOS specification for a list of valid values.” Modified description of DE1000 code “SD”. Updated DE1000 to add codes “AG” – PICC Apportionment Factor Application Indicator, “BP” – BIP (Border Interconnection Percentage), “BQ” – Supplemental BIP (Border Interconnection Percentage), “P0” – Pricing Plan Type Indicator, “P9” – Pricing Plan Level Indicator, “PU” – PIU Source Indicator, ‘UP’- Percent Local Usage, “U1” – USOC Specific Percent Local Usage, “U2” – USOC Specific Percent Intrastate/interLATA Usage, “U3” – USOC Specific Percent Interstate/interLATA Usage, “U4” – USOC Specific Percent Intrastate/intraLATA Usage 09/00 Revisions from September Meeting in Norwood, WA Added code “42” to DE66 with code source information. 82 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Added new DE150 codes “DSP” – Dispute, and “PEN” – Penalty. Added new DE560 codes “RESEC” – Resolved-Exchange Carrier, “UNRES” – Unresolved, “RESCUS” – Resolved-Customer Updated DE1000 to add codes “AQ” – Type of Account, “FA” – Facility Charge Type Indicator, “LH” – Late Payment Charge Applicability/Impact Indicator,”NT” – Shared Line Telephone Number, “PG” – PICC Capacity Type Indicator Channels, “PH” – PICC Capacity Type Indicator Trunks, “PJ” – PICC Capacity Type Indicator Lines, “PY” – PICC Application Indicator, “PZ” – PICC CENTREX Indicator, “RH” – Rate Category Indicator, “RJ” – Rate Zone. Modified description of DE1000 codes “AF”, “AX”, “TK”. Added valid values to DE1000 code “DA”: “30” – 555 Name/Address, “31” – 411 Name/Address, “32” – “Business Listing” Removed valid value “H22” – Discount, from DE1000 code “OC”. Added new valid values to DE1000 code “AX”: “LI” – Link, “LA” – Local, “IT” – Interconnection Trunking. Added new valid values to DE1000 code “CL” : “M” – Measured Rate Residence, “F” – Flat Rate Residence Added new valid value to DE1000 code “DC”, “C” – Combination of Originating and Terminating. Added valid value note to DE1000 codes “RS”, “SG”, “TT”: “For CABS billing applications, see the current issue of OBF’s CABS BOS specification for a list of valid values.” Please report any errors or inconsistencies found in this document to the EDI Guideline Consistency Subcommittee Chair via FAX or Email at the addresses listed below; FAX To: 1-202-393-5481 (ATIS Secretariat), ATTN: EGCS Chair or Email To: ATIS Secretariat, www.atis.org 83 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 ERRATA Sheet Items not included in Summary for June 2003 and changed in 10.4. Sequenced the DE1000 qualifiers “FN” and “FO” into the proper order. Items not included in Summary for March 2002 and changed in 10.4. Changed all references to valid values for DE234 for CABS Billing application to the following to make them consistent: “For CABS billing applications, see current issue of OBF CABS BOS Specifications for a list of valid values”. Changed ASC X12 version from 4020 to 4030. Hyphenated DE234 CODE “RPETRQYT” for DE1000 value “QT”. Items not included in Summary for September 2001 and changed in 10.4. Changed "SWBT" in the Appendix B to say "Southwestern Bell Telephone". Created separate entry for LTEXT in alphabetic sequence under list of phrase codes associated with DE128 qualifier "82". The phrase codes "LISTTEXT" and "LTEXT" had been listed together. Added following verbiage to note on DE235 qualifier "WJ": "For implementations based on X12 version/release prior to 004020 use "ZZ" instead." Removed valid values list from qualifier "ZZ". Added definition to DE751 code "RSUIND". Put DE1000 codes "AO" and "AP" into alphabetic sequence. Items not included in Summary for June 2001 and changed in 10.4. Removed the following verbiage from DE128: OBF Maintained Code Values for N9 and REF Segments. Code values to be used in the N9 Loop at the Header and Detail levels for remarks, notes, error messages, directory listings and directory captions, etc. N901 contains codes of 1Q, 82, H7, L1, etc. and N902 contains the codes of ERR, YPH, ACC, etc. and N903 contains the OBF Field Identification (FID) code, when applicable. The text information for the associated N9 segment, if any, would be carried in the MTX (004020 or above) or MSG (prior to 004020) segment subordinate to the N9. Codes values to be used in the REF02 with REF03 containing the OBF Field Identification (FID) codes. Added the following verbiage to DE128: Codes listed here are those for which: OBF maintains a list of associated "phrase codes" for use in REF02, REF03, N902 or N903 which are listed with the qualifier; OBF's use of the qualifier requires the use of values maintained by an external source. Amended the last sentence in the opening paragraph as follows (changes are underlined): "DE128, DE235 and DE1104 contain code lists that are subsets of ASC X12 maintained code lists for which either OBF maintains associated phrase codes and values, or, associated values are found in an external codelist." 84 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Corrected the definition on DE235 code "ZZ" to the X12 definition "Mutually Defined". This should have been done at the time the code was restored to the list (see Errata for March 2001). Items not included in Summary for March 2001 and changed in 10.4. Changed all occurrences of "premise" to "premises". Corrected miscellaneous spelling errors and inconsistencies in capitalization. Corrected designation for phrase code "LECODE" associated with DE128 code "1Q" from N902 to N903. Restored DE235 code "ZZ" which was removed in error in the December 1998 version when code "WJ" was added. Items not included in Summary for December 2000 and changed in 10.4. Corrected miscellaneous spelling errors and inconsistencies in capitalization. Removed the phrase "(formerly Bellcore)" from all references to Telcordia Technologies. Changed all occurrences of "(Code Source #)" to "(X12 Code Source #)" where "#" is the X12 code source number. Added code source for DE1000 code "LA" - Local Access Transport Area (LATA). Updated code source information for DE1000 code "DB" - Directory Book Code. Deleted the following note and changed all references to it to refer to Note 1: Note 2: This code is to be used only temporarily to meet mandated changes. A request for a new code should be completed within 90 days. Deleted the following note and changed all references to it to refer to Note 1: Note 4: Locally defined codes for temporary use in order to respond to regulatory rulings prior to formal approval process. Renumbered the following note from 3 to 2 and changed all references to it to refer to Note 2: Note 3: This code is not valid when used with ASC X12 Release 3030 or higher. Renumbered the following note from 5 to 3 and changed all references to it to refer to Note 3: Note 5: These codes are only valid with ASC X12 Release 3040 or higher. Renumbered the following note from 6 to 4 and changed all references to it to refer to Note 4: Note 6: These codes are not valid with ASC X12 Release 3040 or higher. Renumbered the following note from 7 to 5 and changed all references to it to refer to Note 5: Note 7: These codes are only valid with ASC X12 Release 3050 or higher. Renumbered the following note from 8 to 6 and changed all references to it to refer to 85 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION Note 6: Note 8: INDUSTRY CONVENTIONS ASC X12 Version 004050 These codes are not valid with ASC X12 Release 3050 or higher. Renumbered the following note from 9 to 7 and changed all references to it to refer to Note 7: Note 9: These codes are not valid with ASC X12 Release 4010 or higher. Renumbered the following note from 10 to 8 and changed all references to it to refer to Note 8: Note 10: These codes are only valid with ASC X12 Release 4010 or higher. Renumbered the following note from 11 to 9 and changed all references to it to refer to Note 9: Note 11: These codes are only valid with ASC X12 Release 4020 or higher. Items not included in Summary for September 2000 and changed in 10.4. Corrected definitions for DE560 codes which had been truncated in error: 17 - Multi-Listing 18 - Multi-Listing by appointment Inserted DE560 codes previously omitted in error: "IA" - Intrastate; "IR" - Interstate. Inserted DE1000 code "IA" previously omitted in error. Corrected valid value entry for DE1000 code "DA" - second occurrence of "28" - 411 Information Call Completion, changed to "29" - 411 Information Call Completion. 86 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.] EDI GUIDELINE GENERAL SECTION INDUSTRY CONVENTIONS ASC X12 Version 004050 Copyright © 2001 ATIS. All rights reserved. ATIS to revise language for the copyright. This document is printed and distributed by the Alliance for Telecommunications Industry Solutions ("ATIS") on behalf of the Ordering and Billing Forum (“OBF”). Except as expressly permitted in the paragraph below, no part of this publication may be reproduced or distributed in any form, in an electronic system or otherwise, without the prior express written permission of ATIS. All requests to reproduce this document shall be in writing and sent to: OBF Committee Administrator, c/o ATIS, 1200 G Street, NW, Suite 500, Washington, DC 20005. Participants in the OBFare hereby authorized to reproduce this document and distribute it within their own business organizations for OBF-related business provided that this notice continues to appear in the reproduced documentation. For ordering information, please contact: ATIS 1200 G Street, NW Suite 500 Washington, DC 20005 (202) 628-6380 www.atis.org 87 [Above is the page number. They are always in 10 point, regular, centered, Arial. Style Sheet: Page number.]