ST 3000 Gauge Pressure Transmitters for High Temperatures Flyer

advertisement
INDUSTRIAL MEASUREMENT & CONTROL
ST 3000® Gauge Pressure Transmitters
For High Temperatures
Field Instrument Solutions
ST 3000® Transmitters for High Temperatures can withstand process temperatures in excess
of 300 degrees Fahrenheit (150 degrees Celsius). Designed to measure pressure or the level
of fluid in open or non-pressurized tanks, these unique transmitters can replace troublesome
capillary-filled remote seal systems to yield better overall accuracy, much greater stability,
and substantially reduced installation and maintenance costs. A patented sensor provides
high-temperature performance and functionality.
Features and Functions
Versatile and Flexible
Applications Capability
ST 3000® Transmitters for High Temperatures
Eliminating a remote-seal capillary
High-temperature capabilities make
address difficult applications in which
system reduces errors due to changes
this product the ideal choice when the
high temperatures prohibit contact
in ambient temperature and fill fluid
process medium:
between the transmitter and the process,
densities. Because remote-seal transmitters
• Is a slurry or has suspended solids
that may clog the instrument line
or where contact could contribute to
eliminating unreliable, troublesome
into a process, replacing them with a more
• Might freeze or solidify due to ambient
or process temperature changes
reliable alternative is highly desirable.
• Has a high temperature.
measurement problems and numerous
are notorious for being troublesome and
often introduce problems of their own
Also, replacing remote seals in sanitary
applications minimizes downtime because
there is no need to remove transmitters
during Clean-In-Place and Sterilize-In-Place
operations. Honeywell’s high-temperature
capability ST
3000 ®s
provide the right
alternative, while offering the same high
level of accuracy as all our highly respected
These devices are well suited for a variety
of industries such as power generation,
clogging or contamination. In addition,
remote seals prevents a multitude of
field and maintenance difficulties. These
effective, accurate transmitters:
industrial energy management, pulp and
• Withstand process temperatures in
paper, hydrocarbon processing, oil and gas,
excess of 300 degrees Fahrenheit
and chemicals. A small flange-mount
model with piping sizes as small as one
inch reduces associated piping, plumbing,
and equipment costs.
ST 3000® transmitters.
(150 degrees Celsius)
• Replace remote seals in many
applications
• Feature a robust Honeywell-
Sanitary Applications
patented sensor that provides greater
Two sanitary models, designed for
performance and functionality than any
food and pharmaceutical applications,
are suitable for Clean-In-Place and
comparable product on the market
• Offer small, flange-mount models
Sterilize-In-Place installations and meet
with piping sizes down to one inch to
3A requirements for non-contamination
reduce associated piping, plumbing,
of the process. The sanitary connection
and equipment costs.
avoids the cavities and dead volume
that often contribute to contamination.
To learn more about the ST 3000 ®
ST 3000® For High Temperatures Specification Summary*
Upper Range Limit
Minimum Span
psig (bar)
psig (bar)
Gauge Pressure Transmitters and other
300 (21)
15 (0.35)
Honeywell field instrument solutions,
Turndown Ratio
20:1
Zero Elevation and Suppression
No limit except minimum span from absolute zero
to 100% of URL
Accuracy (Reference)
±0.075% of calibrated span or upper range value (URV),
whichever is greater
Process Head: 1/ 2-inch NPT.
Process Connections
contact your local Honeywell
representative, or visit our Web site
at www.honeywell.com/imc.
Sanitary: 2-inch Sanitary Tri-Clamp
Flange: 3- or 4-inch Class 150 or 300 ANSI; DN80-PN40
or DN100-PN40 DIN flange.
2", 4", or 6" extension
1/ 2", 1", 11/ 2", and 2" flange
Sanitary Flange Mount: 4-inch sanitary tank spud
with Ladish 4-inch
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being
free of defective material and faulty workmanship.
Contact your local sales office for warranty information.
If warranted goods are returned to Honeywell during
that period of coverage, Honeywell will repair or
Tri-Clamp. See Specification 23-ST-03-26.
replace without charge those items it finds defective.
Diaphragm Materials (wetted)
316L Stainless Steel, Hastelloy C
The foregoing is Buyer’s sole remedy and is in lieu
Gasket Ring Materials (wetted)
316L Stainless Steel, Hastelloy C
of all other warranties, expressed or implied,
Mounting Flange (non-wetted)
Zinc: Chromate-plated Carbon Steel, 304 SS, or 316 SS.
including those of merchantability and fitness for
a particular purpose.
Sanitary Design: 316SS
Fill Fluid
Silicone (DC 200), CTFE (Chlorotrifluoroethylene)
Electronic Housing
Epoxy-polyester hybrid paint. Low copper-aluminum
alloy. Meets NEMA 4X (watertight) and NEMA 7
(explosion proof). IP 66/67
Ambient Temperature
°F / °C
Process Interface Temp.
Humidity
°F / °C
77±2 / 25±1
-40 to 185 / -40 to 85
77±2 / 25±1
-40 to 302 / -40 to 150
10 to 55
0 to 100
0/0
0/0
265 / 18
690 / 48
%RH
Flange Rating
ANSI Class 150 psi/bar
ANSI Class 300 psi/bar
Supply Voltage, Current, and
Load Resistance
While we provide application assistance, personally,
through our literature and the Honeywell Web site,
it is up to the customer to determine the suitability
of the product in the application.
Specifications may change at any time without notice.
The information we supply is believed to be accurate
and reliable as of this printing. However, we assume
no responsibility for its use.
ST 3000 ® is a registered trademark of Honeywell
International Inc.
Voltage Range: 10.8 to 42.4 Vdc at terminals
Current Range: 3.8 to 21.8 mA
Load Resistance: 0 to 1440 ohms
Output (two-wire)
Analog 4 to 20 mA or digital communications DE mode
Supply Voltage Effect
±0.005% span per volt.
Damping Time Constant
Adjustable from 0 to 32 seconds digital dumping
RFI Protection (Standard)
Negligible (20 to 1000 MHz at 30 volts per meter)
CE Conformity (Europe)
89/336/EEC, Electromagnetic Compatibility (EMC) Directive
*See specification 34-ST-03-70 for complete product specifications.
U.S.A.: Honeywell Industrial Measurement and Control, 16404 North Black Canyon Hwy., Phoenix, AZ 85053 • Canada: The Honeywell Centre, 155 Gordon Baker Rd., North York, Ontario M2H 3N7
Latin America: Honeywell Inc., 480 Sawgrass Corporate Parkway, Suite 200, Sunrise, Florida 33325 • Japan: Honeywell K.K., 14-6 Shibaura 1-chome, Minato-ku, Tokyo, Japan 105-0023
Asia: Honeywell Pte Ltd., Honeywell Building, 17 Changi Business Park Central 1, Singapore 486073, Republic of Singapore • Pacific Division: Honeywell Pty Ltd., 5 Thomas Holt Drive, North Ryde
NSW Australia 2113 • Europe and Africa: Honeywell S. A., Avenue du Bourget 3, 1140 Brussels, Belgium • Eastern Europe: Honeywell Praha, s.r.o. Budejovicka 1, 140 21 Prague 4, Czech Republic
Middle East: Honeywell Middle East Ltd., Technology Park, Cert Complex, Block Q, Muroor Rd., Abu Dhabi, U.A.E.
Industrial Measurement and Control
www.honeywell.com/imc
SL-53-550 (5M) Rev. 6/02
©Honeywell International Inc.
Printed in U.S.A
Download