Software Software for a ControlLogix System Your selection of modules and network configuration determines what software packages you need to configure and program your system. The FactoryTalk suite from Rockwell Software extends the Rockwell Automation Integrated Architecture by providing an information tier of software applications and services for production and performance management. Tight integration with the Rockwell Automation Logix control platform, as well as connectivity to third-party and legacy systems can help deliver a seamless flow of high-fidelity data across your enterprise. 1756 System Software If you have You need Order 1756 ControlLogix controller RSLogix 5000 Enterprise Series software 9324 series 1756-CN2, 1756-CN2R 1756-CN2RXT 1756-CNB, 1756-CNBR ControlNet communication module RSNetWorx for ControlNet software (comes with the Standard/NetWorx and Professional Editions of RSLogix 5000 Enterprise Series software) 9324-RLD300NXENE (RSNetWorx option) or 9324-RLD700NXENE (RSLogix 5000 Professional software) or 9357-CNETL3 (RSNetWorx for ControlNet) 1756-DNB DeviceNet communication module RSNetWorx for DeviceNet software (comes with the Standard/NetWorx and Professional Editions of RSLogix 5000 Enterprise Series software) 9324-RLD300NXENE (RSNetWorx option) or 9324-RLD700NXENE (RSLogix 5000 Professional software) or 9357-DNETL3 (RSNetWorx for DeviceNet) 1756-EN2F, 1756-EN2T 1756-EN2TXT 1756-ENBT, 1756-EWEB EtherNet/IP communication module (set the IP address) RSLinx software or BOOTP/DHCP server utility to set IP addresses (RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software) 9324 series Optional 9357-ENETL3 (RSNetWorx for EtherNet/IP) 1756 SERCOS or analog motion module Optional RSNetWorx for EtherNet/IP software (comes with the Standard/RSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software) 1756-DHRIO, 1756-DHRIOXT communication module 1756-DH485 communication module RSLinx software 9324 series 1757-FFLD2, 1757-FFLD4 1757-FFLDC2, 1757-FFLDC4 Foundation Fieldbus linking device RSFieldbus Configuration Software 9308 series Communication card in a workstation RSLinx software (RSLinx Lite comes with RSLogix 5000 Enterprise Series software) 9324 series RSLogix 5000 Programming Software RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms. RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder, structured text, function block diagram, and sequential function chart editors for you to develop application programs. Create your own instructions by encapsulating a section of logic in any programming language into an Add-On Instruction. Logix Designer Application Logix Designer application is a scalable application solution used to program and configure any of the Logix5000 family of controller products. Depending on the functionality required, one or more product catalog numbers might be needed to acquire the appropriate functionality. Use the following tables to help determine which Logix Designer application package is best suited for your application needs. Logix Designer Development Features Logix Designer Bundle⋆ Professional Edition Full Edition Standard/ NetWorx Edition Standard Edition Lite Edition Mini Edition Service Edition‡ Cat. No. 9324RLD700NXENE (English) 9324RLD700NXINT (International) 9324-RLD600ENE (English) 9324-RLD600INTL (International) 9324RLD300NXENE (English) 9324RLD300NXINT (International) 9324-RLD300ENE (English) 9324-RLD300INTL (International) 9324-RLD250ENE (English) 9324-RLD250INTL (International) 9324-RLD200ENE (English) 9324-RLD200INTL (International) 9324-RLD000ENE (English) 9324-RLD000INTL (International) Logix5000 controllers supported CompactLogix5370 ControlLogix5500 SoftLogix5800 GuardLogix5500 CompactLogix5370 ControlLogix5500 SoftLogix5800 Compact GuardLogix5300 GuardLogix5500 CompactLogix5370 ControlLogix5500 SoftLogix5800 Compact GuardLogix5300 GuardLogix5500 CompactLogix5370 ControlLogix5500 SoftLogix5800 Compact GuardLogix5300 GuardLogix5500 CompactLogix5370 Compact GuardLogix5300 CompactLogix5370 Compact GuardLogix5300 CompactLogix5370 ControlLogix5500 SoftLogix5800 Compact GuardLogix5300 GuardLogix5500 Ladder Diagram (LD) Full support Full support Full support Full support Full support Full support Upload/download and view Function Block Diagram (FBD) and Drive control blocks (9324-RLDFBDENE, or via 9324-RLDMLPE) Full support Full support Upload/Download Included, Editor Available Separately Upload/Download Included, Editor Available Separately Full support Upload/Download Included, Editor Available Separately Upload/download and view Sequential Function Chart (SFC) (9324-RLDSFCE, or via 9324-RLDMLPE) Full support Full support Upload/Download Included, Editor Available Separately Upload/Download Included, Editor Available Separately Full support Upload/Download Included, Editor Available Separately Upload/download and view Structured Text (ST)§ (9324-RLDSTXE, or via 9324-RLDMLPE) Full support Full support Upload/Download Included, Editor Available Separately Upload/Download Included, Editor Available Separately Full support Upload/Download Included, Editor Available Separately Upload/download and view PhaseManager (9324-RLDPME) Included Included Upload/Download Included Editor Available Separately Upload/Download Included Editor Available Separately Upload/Download Included Editor Available Separately Upload/Download Included Editor Available Separately Upload/Download Included RSLogix 5000 GuardLogix Safety Editor (9324-RLDGLXE) Included Included Upload/Download Included Editor Available Separately Upload/Download Included Editor Available Separately Full Support♣ ∆ N/A Upload/download and view Advanced Process Control instructions – Design license and runtime license for one controller (9324-RLDAPCENE) Available Separately Available Separately Available Separately Available Separately Available Separately Available Separately Upload/download and view Advanced Process Control instructions – Runtime license for one controller (9324-RLDAPCCLENE) Available Separately Available Separately Available Separately Available Separately Available Separately Available Separately Upload/download and view Highly integrated motion Full support Full support Full support Full support Full support Full Support Upload/download and view Graphical trending Full support Full support Full support Full support Full support Full support Full support FBD PIDE Autotune (requires FBD option) (9323-ATUNEENE) Included Included Available separately Available separately Available separately Available separately Available separately FuzzyDesigner (9324-RLDFZYENE) Available separately Available separately Available separately Available separately Available separately Available separately N/A Redundancy Included Included Included Included N/A N/A Included RSLogix Emulate 5000 (9310-WED200ENE) Included Available separately Available separately Available separately N/A N/A Available separately Routine Source Protection Included Included Included Included Included Included Included Security Server Emulator (FTAP Install Required – include on disk) Included Included Included Included Included Included Included FactoryTalk Security Server Support (FTAP Install Required – included on disk) Included Included Included Included Included Included Included Programming Languages Miscellaneous Features Passwords / Security ⋆ Logix Designer application now ships with only concurrent licensing. Software is designed to use highest functionality license first. For example, if Standard, Full, and Professional licenses are available on the FactoryTalk Activation server, Logix Designer application will use the highest functionality license first (that is, Professional). ‡ Service Edition requires controller firmware at revision 12 or later. § The Structured Text editor option is required to program SFC Actions and SFC Transitions using the Structured Text language. ♣ Lite Edition is the combination of Mini Edition and Multi‐Language Pack activations. Both Mini and MLP need to be activated for CompactGuard when using Lite Edition. ∆ Safety Editor is only applicable for CompactGuard when using Lite Edition. Logix Designer Integration with Other Applications Logix Designer Bundle⋆ Professional Edition Full Edition Standard/ NetWorx Edition Standard Edition Lite Edition Mini Edition Service Edition‡ Cat. No. 9324-RLD700NXENE (English) 9324-RLD700NXINT (International) 9324-RLD600ENE (English) 9324-RLD600INTL (International) 9324-RLD300NXENE (English) 9324-RLD300NXINT (International) 9324-RLD300ENE (English) 9324-RLD300INTL (International) 9324-RLD250ENE (English) 9324-RLD250INTL (International) 9324-RLD200ENE (English) 9324-RLD200INTL (International) 9324-RLD000ENE (English) 9324-RLD000INTL (International) System Configuration / Network / Communications RSLinx Classic Lite included Lite included Lite included Lite included Lite included Lite included Lite included RSLinx Enterprise Included Included Included Included Included Included Included RSNetWorx for ControlNet, DeviceNet, EtherNet/IP (9357-CNETL3, 9357-DNETL3, 9357-ENETL3 individually or 9357-ANETL3 combined) Included Available separately Included Available separately Available separately Available separately Available separately RSLogix Architect (9326-LGXARCHENE) Stand Alone License Included Web Download Required Activated with Logix Designer License Web Download Required Activated with Logix Designer License Web Download Required Activated with Logix Designer License Web Download Required Available separately Available separately Available separately Electronic manuals (PDF) Included Included Included Included Included Included Included Start Page Included Included Included Included Included Included Included ControlFLASH with Firmware Included Included Included Included Included Included Included ClearKeeper Included Included Included Included Included Included Included PLC-5/SLC 500 Translation Tool Included Included Included Included Included Included Included RSLogix 5000 IEC61131-3 Translation Tool Included Included Included Included Included Included Included Tag Data Upload / Download Tool Included Included Included Included Included Included Included RSLogix 5000 Project Compare Tool Included Included Included Included Included Included Included Tag Custom Data Monitor Tool Included Included Included Included Included Included Included DeviceNet Node Commissioning Tool Included Included Included Included Included Included Included Logix5000 Task Monitor Included Included Included Included Included Included Included Logix5000 Clock Update Tool Included Included Included Included Included Included Included Logix5000 Data Preserve Tool Included Included Included Included Included Included Included CGCM PID Calculator Included Included Included Included Included Included Included RSLogix 5000 DeviceNet Tag Generator Included Included Included Included Included Included Included Safety Reaction Time Tool Included Included Included Included Included Included Included GuardLogix Safety Estimator Included Included Included Included Included Included Included Logix Designer Application Upgrades Use Step Forward: http://www.rockwellautomation.com/rockwellautomation/solutions-services/capabilities/stepforward/ Miscellaneous Files & Tools ⋆ Logix Designer application now ships with only concurrent licensing. Software is designed to use highest functionality license first. For example, if Standard, Full, and Professional licenses are available on the FactoryTalk Activation server, Logix Designer application will use the highest functionality license first (that is, Professional). ‡ Service Edition requires controller firmware at revision 12 or later. RSLogix 5000 Enterprise Series Software Requirements Description Value Minimum System Requirements for RSLogix 5000 • Pentium 4 2.8 GHz processor • 1 GB RAM • 16 GB available hard disk space • 1024x768, True Color graphics device Recommended System For Best User Experience And Faster Downloads • Intel Core i5 2.4GHz processor • 8 GB available hard disk space • 20GB available free disk space • DirectX 9 graphics device with WDDM 1.0 or higher driver Operating System Support RSLogix 5000 V20 software has been tested on the following operating systems: • Microsoft Windows 7 Professional (64‐bit) with Service Pack 1a • Microsoft Windows 7 Home Premium (64‐bit) with Service Pack 1 a • Microsoft Windows 7 Home Premium (32‐bit) with Service Pack 1 a • Microsoft Windows Vista Business (32‐bit) with Service Pack 2 b • Microsoft Windows XP Professional with Service Pack 3 • Microsoft Windows Server 2008 R2 Standard Edition with Service Pack 1 • Microsoft Windows Server 2008 Standard Edition with Service Pack 2 • Microsoft Windows Server 2003 R2 Standard Edition with Service Pack 2 Notes 1. User account control (UAC) must be set to “always notify.” 2. User account control (UAC) must be turned on. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.