OptiSystem 13.0.3 Release Notes IMPORTANT - PLEASE READ ME Installation Notes: • It is highly recommended that all previous versions of OptiSystem or OptiSys_Design are removed from the Optiwave Software Programs folder before starting the installation of OptiSystem 13.0.3 • If the length of the installation directory path is too long, it can cause the installation to fail. To avoid this, it is recommended that you not exceed the length of the default installation path • Back up your data before installing OptiSystem 13.0.3 if you are a current user of OptiSystem 12 or earlier. The software installation program supplies a complete set of samples. These samples could overwrite the contents of the samples directory from previous versions of OptiSystem found on your computer. If you have data in the OptiSystem samples directory you want to keep, please make a copy of your samples directory before installing OptiSystem 13.0.3 to avoid losing your data. Minimum hardware and software requirements OptiSystem requires the following minimum/recommended system configuration: • Minimum PC configuration: PC with Pentium 4 processor or equivalent with 2G MB RAM. • Recommended PC configuration: PC with a clock speed > 2 GHz with 2-4 cores (e.g. Intel i7 3rd/4th Gen, AMD Athlon/Athlon II) and 8MB RAM. • Operating Systems: Microsoft Windows 7 & 8.1 (32-bit/64-bit) For optimum software performance, we recommend the 64-bit version of OptiSystem (64-bit version) installed on a Windows 7 (64-bit) or Windows 8.1 (64-bit) operating system. Note: OptiSystem 13.0.3 is only available in the 64-bit version. If you have a 32-bit operating system please contact info@optiwave.com for further assistance. • 400 MB free hard disk space • 1024 x 768 graphic resolution, minimum 65536 colors • Internet Explorer 5.5 or higher (to enable VBScript functionality) Application execution • When running OptiSystem under a Restricted User Profile, place all sample files in the Restricted User's folder, or wherever the user has Read/Write access. It may also be necessary to remove the Read-only flag from the file after the copy is made. This has to do with file permissions - OptiSystem needs to open the file in a read/ write mode. Please contact your network administrator if you need assistance. Also when opening an OptiSystem project it will be necessary to open OptiSystem using the “Run as Administrator” command (right click to see this menu option command) • There are some MATLAB files (.m) included that are necessary to make the samples work properly. Another important point - the path in the MATLAB search path (Main tab of the MATLAB component) has to be updated with the path to the MATLAB files, otherwise the samples will not work. • The path to the Scilab/bin folder has to be added to Scilab component (a parameter field has been created for this purpose), otherwise the Scilab component library will not work. • For the OptiSystem Help feature to function properly, Adobe Acrobat Reader must be installed. To get the latest version please visit the Adobe website at http:// www.adobe.com/. • Some computers provide a power saving feature, Hibernation. If available, this feature is controlled by opening Power Options in Control Panel. Clicking the Hibernate tab, and then selecting the Enable hibernate turns it on. After the computer goes into hibernation, it won't find the Optiwave protection key, and the simulation will stop with a message that the protection key can't be found. Disable the hibernation feature of the computer in order to avoid this problem. OptiSystem Version 13.0.3 list of updates Components Component Library Changes QAM Sequence Generator, QAM Pulse Generator, Electrical QAM Modulator Transmitters/ Modulators/Electrical Improvements were made to the User-defined IQ map feature, including adding the ability to perform sweep iterations of I-Q amplitude files. Issues related to the loading and visualization of binary sequence data (MxN parameters properties) were also fixed. Transmitters/Coders/ Electrical Transmitters/Pulse Generators/Electrical PIN Photodiode Receivers Library/ Photodetectors The calculation for Shot noise has been improved by allowing for direct control over the time interval used to calculate the photon count. Also the Noise parameters properties have been re-organized, including a new menu parameter which allows users to select the source of the noise bandwidth for thermal and shot noise calculations Dual Port WDM Analyzer Visualizers/Optical A new parameter option was added to allow users to select the noise input option for the NF calculation: EDFA with shot-noise limited input, From external input noise Multimode Generator Multimode/Mode Generators/ New parameters were added to the Multimode Generator to allow for the generation of LP fiber modes. X Coupler Passives/Optical/ Couplers A new result was added to the X Coupler to display the relative phase shift setting (conjugate) of the coupler Pulse Generators Transmitters Library/ Pulse Generator/ Electrical A minor update was applied to the naming of parameters, specifically the “Peak Amplitude” parameter was renamed to “Amplitude (wrt DC)”: NRZ Pulse Generator, Gaussian Pulse Generator, Hyperbolic-Secant Pulse Generator, Triangle Pulse Generator, Saw-Up Pulse Generator, SawDown Pulse Generator, Impulse Generator, Raised Cosine Pulse Generator, Sine Pulse Generator, Measured Pulse, RZ Pulse Generator Documentation Document Changes OptiSystem Component Library The following updates were applied to this document: 1) The technical descriptions of the following electrical pulse generators were updated (inc. new example diagrams) to provide further details on the Width, Position, Min/Max, Amplitude/DC Bias settings: NRZ Pulse Generator, Gaussian Pulse Generator, Hyperbolic-Secant Pulse Generator, Triangle Pulse Generator, Saw-Up Pulse Generator, Saw-Down Pulse Generator, Impulse Generator, Raised Cosine Pulse Generator, Sine Pulse Generator, Measured Pulse, RZ Pulse Generator 2) The help sections of the Single Port and Dual Port WDM Analyzer components were updated to align with new parameters and results introduced in OptiSystem releases 13.0.2 and 13.0.3. 3) The help section of the PIN photodiode component was updated to reflect calculation improvements to the Shot noise feature and changes to the organization of the Noise parameters properties 4) The help description of the BER Test Set was updated to reflect the addition of new OFDM parameters to the component properties 5) The technical description of the OSA Visualizer was updated to include a more detailed description of the Resolution bandwidth feature. 6) The technical descriptions of the DSP and Decision components were updated to include more details on how the down-sampling functions are performed by these components. OptiSystem Version 13.0.3 issues and outstanding items Components • Optical Switches. The control signal function for the optical switch components is not working as defined. When the control signal is changed (from 1 to 0 or from 0 to 1), the switch is not changing from its first state condition (of 0 or 1). This defect affects the follows components: Digital Optical Switch, Optical Y Switch, Optical Y Select, Ideal Y Switch, Ideal Y Select, Ideal Switch 2x2, Ideal Y Switch1x4, Ideal Y Select 4x1, Ideal Y Select Nx1, Ideal Y Switch1x8, Ideal Y Select 8x1, and Ideal Y Switch 1xN. Target release for fix: TBD • PIN and APD photodiodes. The PIN component was updated to include new calculations and results for noise and transfer function analysis. These changes were not captured for the APD component. Target release for update: OS 14.0.0 Documentation • OptiSystem Getting Started. Recent changes to the Global Parameters (such as Symbol rate and Guard bits) have not yet been added to the OptiSystem Getting Started Guide.Target release for update: OS 14.0.0