KTC-Illustrated-spec-REV B

advertisement
KUWAIT TRADE CENTRE
ILLUSTRATED LIGHTING SPECIFICATION,
100% design, Exterior, Interior public area,
Shopping mall
REVISION B
Specification No 0429-.
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
elucidation(2000)ltd. incorporated in scotland
no. sc213106 registered office as above
h t t p : / / w w w. k e v a n - s h a w. c o m
CONTENTS
1.
GENERAL
2.
2.1
2.2
2.3
2.4
EQUIPMENT
General
Light fittings
Lamps
Control Gear
3.
FOCUSING AND COMMISSIONING
4.
HAND OVER
5.
5.1
LUMINAIRE ILLUSTRATED SPECIFICATION
Lighting Equipment Schedule (Summarised)
6.
6.1
6.2
ARCHITECTURAL LIGHTING CONTROL
Lighting Control strategy
Circuit Schedule
7.
LIST OF SPECIFIED MANUFACTURERS AND SUPPLIERS
LIGHTING SPECIFICATION KEY
Prefix
F - FREESTANDING
P - PENDANT/SUSPENDED
R - RECESSED
S - SURFACE MOUNTED
T - TRACK MOUNTED
W - WALKOVER
G - GEAR
EXAMPLE:
TYPE - P4e is suspended luminaire wired to central battery
KEVAN SHAW LIGHTING DESIGN
GENERAL SPECIFICATION
1 General
1.1 The contractor shall be responsible for the correct supply, installation, wiring, etc., in conformance with
relevant regulations and codes of practice including B.S.7671: 2001, of the lighting equipment described in
this specification and lighting drawings and schedules prepared by the electrical engineer. The specification is
only concerned with the specific requirements of the client and is not intended to, or should be understood
to free the contractor from statutory obligations with regard to electrical wiring and safety or any relevant
British Standards, legislation, or code of practice.
1.2 The contractor shall ensure that the work is completed in a timely and satisfactory manner and appropriately coordinated with other trades working on the site.
1.3 The contractor shall ensure that the site is left in a clean and tidy state and shall dispose of all waste as
laid down in “Environmental Policy” and shall retain copies of all waste transfer notes for inspection by the
client’s site agents.
1.4 The contractor shall ensure work is carried out in a safe manner and shall be responsible for ensuring
conformance with H. & S.E. guidelines and conform to requirements of C.O.S.H.E. regulations.
2 Equipment
2.1 General
2.1.1 Equipment shall be as described in the illustrated schedule attached. The contractor shall obtain all
equipment as specified from the indicated manufacturer. The contractor shall ascertain lead times from
suppliers for equipment as specified and shall ensure all orders are placed in time to allow for any delays in
supply that may occur.
2.1.2 The contractor shall be responsible for any direct or consequential costs of delays in sourcing of equipment. The contractor shall inform the construction manager immediately if there is likely to be any late delivery of equipment that may cause any delay to the contract.
2.1.3 The contractor shall ensure that equipment as supplied conforms to relevant British Standards, requirements of licensing authorities and can be installed in accordance with B.S. 7671:2001 and any other relevant
standards, legislation and approval . All fittings shall be C.E. Marked and Certificates of Conformity shall be
provided.
2.2 Light Fittings
2.2.1The fittings shall be as defined in the attached schedule.
2.2.2 The contractor shall provide a working sample of each light fitting type for final approval prior to
placing an order. Fittings shall be functionally checked for operation throughout the entire control range.
Each sample shall be tested locally by the Lighting Control System Supplier to ensure correct operation
with the Lighting Control System. Each sample shall be tagged and signed by the Lighting consultant, architect and project manager on acceptance and retained safely stored on site as a control sample until the
completion and hand over of the project. Any fittings subsequently supplied that are judged by the design
team not to match the approved control sample for quality of construction, operation or finish shall be
rejected.
2.2.3 Fittings shall be installed according to the manufacturers instructions supplied and in accordance with
details and instructions in the drawings and specifications, relevant codes of practice and legislation in force
at the time of installation.
2.2.4 Fittings shall be handled with care to protect their finishes. The contractor shall be responsible for
safe storage of fittings prior to erection and shall replace any fitting or part thereof damaged in handling or
installation.
2.2.5 The contractor shall ensure that fittings and lamps are protected from contamination by dust, fumes,
moisture or any other hazard common to building sites. Should contamination occur, fittings shall be cleaned
carefully in accordance with manufacturers instructions. Care must be taken not to damage reflectors and
lenses during cleaning, as this seriously degrades the performance of the fitting.
2.2.6 The contractor shall ensure that forming openings, installation of fittings, final finishes etc. are programmed so that none of these operations causes damage to works already complete and that paint plaster etc. cannot contaminate the finishes of fittings.
2.2.7 The contractor shall ensure that any fixings taken are suitable for the intended design load. The contractor shall confirm suitability of locations of fixings and imposed loads with the architect or structural engineer. Fixings for lighting track, suspensions, cantilevers, brackets etc. shall be dead weight tested to 2 times
their maximum rated load prior to erection of track or fittings
2.3 Lamps
2.3.1 Low voltage reflector lamps shall be supplied with a glass front providing protection against non-passive failure of the capsule and to reduce the emission of UV rays to a negligible level. The lamps shall be
precisely as specified in the attached schedules and specification. Please note exact specification of lamp
type and rating to ensure that correct fitting performance is obtained and that the lamp is suitable for the
fitting in which it is installed. Any lamps that do not conform to this specification will be rejected
2.3.2 Low Voltage capsule lamps shall be precisely as specified in the attached schedules and specification
and shall conform to the type specification as indicated with regard to construction, light output and operating life. Any lamps that do not conform to this specification will be rejected.
2.3.3 Mains voltage and discharge lamps shall be precisely as specified in the attached schedules and specification. All lamps shall be rated suitably and intended for use in the UK. Lamps sourced internationally may
be incorrectly rated and will not achieve correct operating life.
2.3.4 Fluorescent lamps are to be precisely as specified in the attached schedules and specification. Where
a manufacturer, colour or tube type are shown in the specification these are to be supplied exactly, substitution is not acceptable without prior written instruction. Any lamps that do not conform to this specification
will be rejected.
2.3.5 Cold Cathode lamps shall be manufactured and installed by an approved supplier. The supplier shall
provide operating samples of tube to determine colour and surface illuminance for approval by the construction manager prior to manufacture.
2.3.6 The contractor shall ensure that all lamps installed at hand over meet the manufacturer’s published
performance criteria for light output, colour rendition and photometric performance. Noticeable variations
in colour output between lamps will not be accepted neither will noticeable variation of light output from
similar lamps.
2.3.7 The contractor shall be responsible for replacement of all lamps judged to have failed prematurely according to the manufacturer’s stated life of that lamp, as timed from date of hand over.
2.4 Control Gear
2.4.1 Control gear including low voltage transformers is to be supplied as indicated in the drawings and
schedules.
2.4.2. Where there is any discrepancy in part number, rating or performance due to manufacturers change
of design, part numbers, advised substitution or error the construction manager and client’s consultant are
to be informed immediately and prior to the contractor placing the order for such equipment.
2.4.3 Where any piece of lighting control gear has a tapping or adjustment for mains input voltage the
contractor is to measure the voltage at the fitting at time of switch on and ensure the connections are
made according to the measured voltage. Where fittings are installed and made operational prior to the full
building load being applied to the substation the contractor shall re-measure and re-tap the control gear as
necessary when the full load has been applied to the substation and subsequent to the final voltage settings
being made at the substation.
3 Focusing and Commissioning
3.1 The client’s lighting consultant will require to supervise focusing of all adjustable light fittings. The contractor will advise the client’s consultant of suitable times The contractor shall allow not less than 21 days,
not necessarily continuous or sequential, attendance in respect of this requirement. It shall be noted that a
considerable amount of time will be required out with normal working hours and at weekends to accommodate focussing and adjustment during hours of darkness and at times when switching lighting on and off
shall not inconvenience or compromise safety of other contractors working on the site. Some final adjustments may be required subsequent to client occupation of the building.
3.2 The contractor shall provide sufficient access and safety equipment for focusing of fittings at high level.
The contractor shall ensure the full, exclusive and unhindered use of any such equipment for the entirety of
any focusing session by the consultant and shall ensure that suitably trained and certificated operatives are
present for the duration of the use of such equipment within their normal allowance of working hours.
3.3 The contractor shall ensure that all fittings to be focused in any session shall be fully working and correctly lamped prior to the commencement of the focusing session.
3.4 The contractor shall supply at least two competent electricians one of which must be the foreman or
charge hand for the installation and fully familiar with the layout of wiring and switching and control system,
as installed , for the period of any focusing or commissioning session.
3.5 The contractor shall make all reasonable facilities available to any supplier of light fittings for inspection,
commissioning, installation or remedial work required on site.
4 Hand Over
4.1 The contractor shall ensure all light fittings, reflectors and lamps have been cleaned and are all operating
correctly in accordance with drawings, focus instructions, site instructions etc.
4.2 The contractor shall hand over to the client any unused or surplus fittings and control gear, in a clean
and reusable condition preferably in their original packing, otherwise adequately packed for storage.
KSLD
5. LUMINAIRE ILLUSTRATED SPECIFICATION
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
F01
DESCRIPTION:
Free standing indirect pole type luminaire with HIT 70w lamp. Constructed with Mica DB 701finish steel
pole, base to be either flange or root mount, exact mounting method to be developed. Light fitting made
of natural anodised aluminium with Borosilicate glass lamp cover and aluminium light shade/reflector. Fitting height 3180mm. Integral control gear.
LUMINAIRE
Manufacturer
Hess
LAMP
Manufacturer
Osram
Accessories
Catalogue No.
LPH 2730:12.01111.2730
Catalogue No.
HCI-TC 70/WDL
Notes
Wattage
70W
Fitting Dimensions
Notes
Architect to confirm type of mounting required before ordering.
Illustration
issue date November
PAGE: 8
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
F02
DESCRIPTION:
Free standing floor washlinght luminaire with 35w CDM lamp to IP55 protection and integral gear. Fitting
constructed from anti-corrosion aluminium with double powder coating and stainless steel lens cover.
Optics are to consist of asymmetric silver anodised reflector with anti-glare lamp cap and reeded glass
sculpture lens with no direct light emission and a cut off below horizontal. fitting to allow mounting options of root or base plate, Architect to confirm mounting before ordering
LUMINAIRE
Manufacturer
Erco
Catalogue No.
33314.006
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-TC-35/WDL
Wattage
35W
Accessories
Fitting Dimensions
Notes
Architect to confirm type of mounting required before ordering.
Illustration
issue date November
PAGE: 9
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R01
DESCRIPTION:
Recessed IP65 exterior CDM downlight constructed from cast aluminium with powder coat finish
where required. Fitting to have a cast aluminium housing/heat sink for operation of 70w CDM lamp
with integral control gear. Fitting to have 40 degree cut-off and frosted glass lamp cover/diffuser.
Note ftg type to be confirmed as canopy integration detail is confirmed, lights must not be ordered
without architects approval.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
81050.006
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-T70/WDL
Wattage
70W
Accessories
Fitting Dimensions
Notes
Illustration
issue date November
PAGE: 10
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R02
DESCRIPTION:
Recessed CDM downlight constructed from cast aluminium with powder coat finish where required.
Fitting to have a cast aluminium housing/heat sink for operation of 35w CDM lamp with remote control gear. Fitting to have 40 degree cut-off and frosted glass lamp cover/diffuser.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
81636 + 83670
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-35/WDL
Wattage
35W
Accessories
Fitting Dimensions
Remote control gear 83670.006
Notes
Illustration
issue date November
PAGE: 11
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R03
DESCRIPTION:
Recessed fluorescent Washlight for 26w fluorescent lamp. Fitting to have a cast aluminium housing/heat
sink for operation of 26w fluorescent lamp with integral electronic control gear. 40 degree cut-off and
translucent plastic lamp cover/diffuser. Reflector to have washlight optic. Dimmable gear to be provided.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22277
Notes
LAMP
Manufacturer
Osram
Catalogue No.
Dulux T/E 26 W/840
Wattage
26W
Accessories
Fitting Dimensions
Dimmable gear
Notes
Illustration
issue date November
PAGE: 12
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R04
DESCRIPTION:
Recessed fluorescent Downlight for 26w fluorescent lamp. Fitting to have a cast aluminium housing/
heat sink for operation of 26w fluorescent lamp with integral electronic control gear. 40 degree cut-off
and translucent plastic lamp cover/diffuser. Reflector to have beam angle of approx 100 degrees. Dimmable gear to be provided.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22237
Notes
LAMP
Manufacturer
Osram
Catalogue No.
Dulux T/E 26 W/840
Wattage
26W
Accessories
Fitting Dimensions
Dimmable gear
Notes
Illustration
issue date November
PAGE: 13
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R05
DESCRIPTION:
Recessed fluorescent wallwasher. Fitting to be constructed with BLACK steel powder coated housing
with white powder coated cast aluminium mounting ring. Darklight plastic reflector with vapourised
mirror finish aluminium giving wallwash photometrics and 40 degree cut off away from wall side. Integral dimmable electronic control gear and 2x26w compact fluorescent lamps.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
82512
Notes
LAMP
Manufacturer
Osram
Catalogue No.
2 x DULUX D/E 26W/840
Wattage
26W
Accessories
Fitting Dimensions
Notes
Illustration
issue date November
PAGE: 14
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R06
DESCRIPTION:
Recessed wall mounted IP65 low voltage tungsten floorwash luminaire Fitting constructed from anticorrosion aluminium with double powder coating and stainless steel lens cover. Optics are to consist
of asymmetric silver anodised reflector with anti-glare lamp cap and reeded glass sculpture lens with
no direct light emission and a cut off below horizontal. Integral transformer.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
33300.000
Notes
LAMP
Manufacturer
Osram
Catalogue No.
464405S
Wattage
20W
Accessories
Fitting Dimensions
Mounting accessories as required to
manufacturers recommendations
Notes
Illustration
issue date November
PAGE: 15
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R07
DESCRIPTION:
Recessed low voltage underwater pool light to safety class 3 and IP68. constructed from Stainless steel
to take PAR 56 lamp. 3m of HO7RN-F waterproof cable to be provided, remote 300vA transformer
required.
LUMINAIRE
Manufacturer
Bega
Catalogue No.
9912 + 484
Notes
LAMP
Manufacturer
Osram(Europe)
Catalogue No.
Halopar 56 12V WFL
Wattage
300W
Accessories
Fitting Dimensions
Pool specialsit to confirm mounting
requirements before ordering.
Notes
Remote transformer ref. 484
Illustration
issue date November
PAGE: 16
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R08
DESCRIPTION:
Recessed low voltage directional downlight to allow 0-30 degree tilt, 360degree rotation. fitting constructed from cast aluminium for lamp holder/heat sink, white plastic mounting ring and vapourised
aluminium/plastic reflector with cut off angle of 30 degrees. Remote transformer to be provided
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22407 + 83831.006
Notes
LAMP
Manufacturer
Osram
Catalogue No.
48865F
Wattage
35W
Accessories
Fitting Dimensions
Trailing edge transformer Mode ET105-Puma
Notes
Illustration
issue date November
PAGE: 17
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R09
DESCRIPTION:
Recessed CDM downlight constructed from cast aluminium with powder coat finish where required.
Fitting to have a cast aluminium housing/heat sink for operation of 70w CDM lamp with remote control gear. Fitting to have 50 degree cut-off and frosted glass lamp cover/diffuser. Mounting ring to be
provided to allow top relamping.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
81641(70) + 83671
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-70/WDL
Wattage
70W
Accessories
Fitting Dimensions
Remote control gear 83671
Notes
Mounting ring for top relamping
83958
Illustration
issue date November
PAGE: 18
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R10
DESCRIPTION:
Recessed miniture LED downlight with 1w cool white LUXEON LED. Fitting constructed from machined natural aluminium. Remote control gear to be provided to allow operation of multiple fittings.
Note gear to go in ceiling void, access to gear through ceiling void.
Cut-out=mm
Overall dimaeter=38mm
LUMINAIRE
Manufacturer
Mike Stoane Lighting
LAMP
Manufacturer
Lumilux
Accessories
Remote control gear per 10 ftgs,
Philips Xitanium 9137-05-18806
Catalogue No.
E1581.star + E1581 power supply
Notes
Catalogue No.
Wattage
1W
Fitting Dimensions
Diameter
38mm
Cut-out 32mm
Recess depth 40mm
Notes
Illustration
issue date November
PAGE: 19
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R11
DESCRIPTION:
Recessed low voltage downlight. Fitting constructed from cast aluminium for lamp holder/heat sink,
white plastic mounting ring and vapourised aluminium/plastic reflector with cut off angle of 30 degrees.
Remote transformer to be provided
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22405 + transformer
Notes
LAMP
Manufacturer
Osram
Catalogue No.
48865SP
Wattage
35W
Accessories
Fitting Dimensions
Trailing edge transformer Mode ET105-Puma
Notes
Illustration
issue date November
PAGE: 20
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R12
DESCRIPTION:
Recessed directional downlight . Fitting constructed from machined aluminium with 360 pan and 45
degree tilt with mechanical locking mechinism. Fitting to take louvres and lenses as required. Remote
control gear required as recommended by manufacturer.
LUMINAIRE
Manufacturer
Mike Stoane Lighting
Catalogue No.
ADL.CDMR111
Notes
LAMP
Manufacturer
Philips
Catalogue No.
CDMR111, 10 degrees
Wattage
35W
Accessories
Fitting Dimensions
Remote control gear as recommended by manufacturer
Notes
Illustration
issue date November
PAGE: 21
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R13
DESCRIPTION:
Recessed low voltage downlight to allow. Fitting constructed from cast aluminium for lamp holder/heat
sink, white plastic mounting ring and vapourised aluminium/plastic reflector with cut off angle of 30
degrees. Remote transformer to be provided
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22405 + transformer
Notes
LAMP
Manufacturer
Osram
Catalogue No.
48870FL
Wattage
50W
Accessories
Fitting Dimensions
Trailing edge transformer Mode ET105-Puma
Notes
Illustration
issue date November
PAGE: 22
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R14
DESCRIPTION:
Recessed CDM downlight constructed from cast aluminium for housing with powder coat finish cast
aluminium mounting ring to allow mechanical screw fixing Fitting to have a cast aluminium housing/heat
sink for operation of 70w CDM lamp with remote control gear and 500mm connecting cable. Fitting to
have 40 degree cut-off and frosted glass lamp cover/diffuser. Relector to be bright anodised aluminium.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22680 + 83671
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-T 70/WDL
Wattage
70W
Accessories
Fitting Dimensions
Remote control gear 83671
Notes
Illustration
issue date November
PAGE: 23
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
R15
DESCRIPTION:
Recessed Tungsten Halogen low voltage downlight constructed with a cast aluminium housing/heatsink
withRAL 9002 powder coat finish cast aluminium mounting ring to allow mechanical screw fixing Fitting to have a cast aluminium housing/heat sink for operation of 90w LVTH capsule lamp with remote
transformer and 500mm connecting cable. Fitting to have 40 degree cut-off and frosted glass lamp
cover/diffuser. Relector to be bright anodised aluminium.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
22453
Notes
LAMP
Manufacturer
Osram
Catalogue No.
64458S
Wattage
90W
Accessories
Fitting Dimensions
Trailing edge transformer Mode ET105-Puma
Notes
Illustration
issue date November
PAGE: 24
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S01
DESCRIPTION:
Surface mounted IP68 flexible linear xenon lighting. Fitting constructed from Polycarbonate with miniture Xenon lamps. Sectional size of fitting 12.8mm diameter, length as required from site measurments,
with transformers as recommended by manufacturer. Lamp type to be 28v 40mA at with minimium of
25,000hr lamp life, transformer to supply 24v maximium. Lamp spacing to be 50mm. Fitting comes with
1 no. C128 tube clip per 500mm.
LUMINAIRE
Manufacturer
Lightgraphix
Catalogue No.
Light tube LT12 + C128+ transformers
Notes
LAMP
Manufacturer
Catalogue No.
Wattage
Accessories
Fitting Dimensions
Remote transformer as supplied by
manufacturer
Notes
Plastic surface mounting brackets as
required to be provided
Illustration
issue date November
Note dimensions show overall size
of fitting with clear plastic mounting
clip C128.
PAGE: 25
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S02
DESCRIPTION:
Surface mounted low voltage robotically manufacturered Cold Cathode to total length as shown on
drawings, (Note exact length must be determined from site measurements). C/w remote control gear to
allow dimming between 5% and 100% using 1-10Volt signal.
LUMINAIRE
Manufacturer
AC/DC lighting
Catalogue No.
low voltage cold cathode, warm white
LAMP
Manufacturer
Catalogue No.
Masonlite no. 3 warm white 3000k tri-phosphor
Accessories
Notes
Wattage
Fitting Dimensions
High frequency control gear to allow dimming between 5% and 100%
Notes
Illustration
issue date November
PAGE: 26
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S03
DESCRIPTION:
Surface mounted 3 x 60lum. White LED adjustable fitting with surface mounting stirrup. Remote control
gear is required to allow operation of up 8 no. fittings at 30m distance. Constructed from Silver anodised
aluminium to IP67 protection. Note, cable length to be 4m.
LUMINAIRE
Manufacturer
AC/DC lighting
LAMP
Manufacturer
Luxeon
Accessories
Catalogue No.
Artemis + ACDC1903
Notes
Catalogue No.
Wattage
3 x 1w
Fitting Dimensions
Control gear for up to 8 ftgs, ACDC
1903, 1 no. control gear per 6 ftgs
to be provided
Notes
Illustration
issue date November
PAGE: 27
Illustrated Specification
kevan shaw lighting design
KUWAIT TRADE CENTER
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
KSLD Schedule Reference
S04
DESCRIPTION:
Surface mounted IP65 exterior grade colour changing luminaire constructed from Extruded and machined Aluminium with natural colour anodising. Integral DMX controlled gear and colour changing unit
using no more than 6 DMX channels with dimming mechanism. 36 degree fresnel lens. Unit designed to
EN50081/2-1 and US ANSI/UL 1573.
LUMINAIRE
Manufacturer
Martin
Catalogue No.
Notes
Exterior 200 90509000+91610022 fresnel lens
LAMP
Manufacturer
Osram
Catalogue No.
HQI-T 150/NDL UVS
Accessories
Wattage
150w
Fitting Dimensions
C/W mounting stirrup and Fresnel
lens to allow 36 degree beam angle.
Notes
Illustration
WeightLengthwidthHeight-
issue date November
15kg
301mm
306mm
422mm
PAGE: 28
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S05
DESCRIPTION:
Surface mounted three colour cold cathode colour changing unit mounted onto aluminium channel suitable for surface mounting. DMX or 1-10V control interface. Ftg length and configuration to be developed.
Note length must be confirmed before ordering. C/w control gear as recommended by manufacturer.
LUMINAIRE
Manufacturer
ACDC
LAMP
Manufacturer
Masonlite
Accessories
Catalogue No.
Colourise
Notes
Catalogue No.
Wattage
Fitting Dimensions
Control gear as required to manufacturers recommenrdation
Notes
Illustration
issue date November
PAGE: 29
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S06
DESCRIPTION:
Surface mounted linear colour changing LED luminaire. Constructed from silver powder coated extruded aluminium and stainless steel with clear cover. Nominal Length of unit 1200mm, remote control
gear required for each unit. colour changing by DMX control.
LUMINAIRE
Manufacturer
ACDC
LAMP
Manufacturer
Luxeon
Accessories
Catalogue No.
Lucinda
Notes
Catalogue No.
Wattage
1w
Fitting Dimensions
Remote control gear ACDC1906
Notes
Illustration
issue date November
PAGE: 30
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S07
DESCRIPTION:
Weather resisitant Umbrela light, rechargable battery powered LED for 8 rib umbrella, total 64 lamps.
Batteries and changer as optional extras. 30,000hr life expectancy. Cool white light, non insect attracting,
c/w pole adaptor
LUMINAIRE
Manufacturer
Dayva International
Catalogue No.
Night Lights LED
Notes
LAMP
Manufacturer
Catalogue No.
Wattage
Accessories
Fitting Dimensions
batteries and charger
Notes
Illustration
issue date November
PAGE: 31
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
S08
DESCRIPTION:
Surface mounted low voltage robotically manufacturered Cold Cathode to total length as shown on
drawings, (Note exact length must be determined from site measurements). C/w remote control gear to
allow dimming between 5% and 100% using 1-10Volt signal.
LUMINAIRE
Manufacturer
AC/DC lighting
Catalogue No.
low voltage cold cathode, cool white
LAMP
Manufacturer
Catalogue No.
Masonlite no. 7 snow white 6500k tri-phosphor
Accessories
Notes
Wattage
Fitting Dimensions
High frequency control gear to allow dimming between 5% and 100%
Notes
Illustration
issue date November
PAGE: 32
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
T01
DESCRIPTION:
Surface mounted 3 cct track to take fittings with Erco track adaptors. Length as required from site measurement. Construction of extruded aluminium, c/w live ends and dead ends as required. fixing to be as
per manufacturers recommendation
LUMINAIRE
Manufacturer
Erco
Catalogue No.
as required
Notes
LAMP
Manufacturer
Catalogue No.
Wattage
Accessories
Fitting Dimensions
Live ends, dead ends and connecting
pieces as required
Notes
Illustration
issue date November
PAGE: 33
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
T02
DESCRIPTION:
Track mounted adjustable fitting with spread lens to fit Erco track. Constructed from natural brushed
alumimium with plastic components and lampholder. Integral transformer, fitting to be fully lockable.
LUMINAIRE
Manufacturer
Mike Stoane LIghting
Catalogue No.
MRX.MR16
Notes
LAMP
Manufacturer
Osram
Catalogue No.
48870SP
Wattage
50W
Accessories
Fitting Dimensions
Notes
Illustration
issue date November
PAGE: 34
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
T03
DESCRIPTION:
Track mounted adjustable fitting with spread lens to fit Erco track. Constructed from natural brushed
alumimium with plastic components and lampholder. Integral control gear, fitting to be fully lockable.
LUMINAIRE
Manufacturer
Mike Stoane LIghting
Catalogue No.
MRX.BGT
Notes
LAMP
Manufacturer
Philps
Catalogue No.
CDMR111 35w 10 degree
Wattage
35W
Accessories
Fitting Dimensions
Notes
Illustration
issue date November
PAGE: 35
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule ReferenceUW01A
DESCRIPTION:
Surface mounted IP68 linear colour changing LED luminaire. Constructed from T6050 grade aluminium
or similiar non corrosive metal suitable for use in clorinated fountains. Fitting to have a cluster of 3 no.
liquid lensed Luxeon RBG LEDs per 100mm, fitting to be IP68 to be encapsulated to prevent ingress of
liquids up to 2m below water. Control by DMX, control unit to be able to mount 50m from fitting. All
Luxeon LED's to be Bin matched for stability and colour intensity. Standard length of fitting to be 600mm
length as required.
LUMINAIRE
Manufacturer
Optino
LAMP
Manufacturer
Luxeon
Accessories
Catalogue No.
OPT-1053-A
Notes
Catalogue No.
Wattage
1w
Fitting Dimensions
Remote control gear to allow DMX
RGB control
Notes
Illustration
issue date November
PAGE: 36
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule ReferenceUW01B
DESCRIPTION:
Surface mounted IP68 linear colour changing LED luminaire. Constructed from T6050 grade aluminium
or similiar non corrosive metal suitable for use in clorinated fountains. Fitting to have a cluster of 3 no.
liquid lensed Luxeon RBG LEDs per 100mm, fitting to be IP68 to be encapsulated to prevent ingress
of liquids up to 2m below water. Control by DMX, control unit to be able to mount 50m from fitting.
All Luxeon LED's to be Bin matched for stability and colour intensity. Standard length of fitting to be
1200mm.
LUMINAIRE
Manufacturer
Optino
LAMP
Manufacturer
Luxeon
Accessories
Catalogue No.
OPT-1053-A
Notes
Catalogue No.
Wattage
1w
Fitting Dimensions
Remote control gear to allow DMX
RGB control
Notes
Illustration
issue date November
PAGE: 37
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference UW02
DESCRIPTION:
Surface mounted IP68 underwater luminaire. Constructed from stainless steel with remote transformer.
Note standard cable length 4m, longer can be supplied on request. Remote transformer required, exact
confirguration of control gear to be confirmed
LUMINAIRE
Manufacturer
Bega
Catalogue No.
8509
Notes
LAMP
Manufacturer
GE
Catalogue No.
35PAR36/VNSP/H
Wattage
35W
Accessories
Fitting Dimensions
Remote transformer to manufacturers recommendation.
Notes
Cable length to be confirmed with
engineer and water specialist
Illustration
issue date November
PAGE: 38
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
W01
DESCRIPTION:
Recessed inground drive over IP68 adjustable uplight constructed from corrosion resistant cast aluminium, black double powder coated. Directional reflector and anti-dazzle cylinder with 40 degree cut-off to
take 70w CDM lamp and integral control gear.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
33726
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-T 70/WDL
Wattage
70W
Accessories
Fitting Dimensions
Notes
Illustration
issue date November
PAGE: 39
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
W02
DESCRIPTION:
Recessed blue linear luminaire to IP68 protection. Constructed from extruded aluminium with encapsulated LED unit with blue LED's and polycarbonate cover. Remote gear required at location to be confirmed. Load resistence to be 60J minimium, suitable for light vehicular traffic and pedestrian use.
LUMINAIRE
Manufacturer
LEC
LAMP
Manufacturer
na
Accessories
Catalogue No.
Brunei, 5620 + control gear
Notes
Catalogue No.
Wattage
Fitting Dimensions
Remote control gear
Notes
Cable length to be confirmed
Illustration
issue date November
PAGE: 40
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference
W03
DESCRIPTION:
Recessed inground drive over IP68 adjustable uplight constructed from corrosion resistant cast aluminium, black double powder coated. Directional reflector and anti-dazzle cylinder with 40 degree cut-off to
take 35w CDM lamp and integral control gear.
LUMINAIRE
Manufacturer
Erco
Catalogue No.
33718
Notes
LAMP
Manufacturer
Osram
Catalogue No.
HCI-T 35/WDL
Wattage
35w
Accessories
Fitting Dimensions
Notes
Illustration
issue date November
PAGE: 41
kevan shaw lighting design
4 baltic street, edinburgh, eh6 7bw, scotland
phone: +44(0) 131 555 5553
fax: +44(0) 131 555 5559
email:office@kevan-shaw.com
Illustrated Specification
KUWAIT TRADE CENTER
KSLD Schedule Reference WU01
DESCRIPTION:
Surface mounted Anemometer wind sensor utilising ultrsonic sensors. Sensor to come with 1.6m
mast and RS232 cable suitable for PC serial port RS232, note extension cable may be required from
converter(not supplied) to PC. Anemometer to allow for low start up speed(0.01 m/s) and 0-360 degree
operation. 9v DC power imput required.
LUMINAIRE
Manufacturer
Richard Paul Russell ltd
LAMP
Manufacturer
na
Accessories
Catalogue No.
System1
Notes
Catalogue No.
Wattage
Fitting Dimensions
9v DC power to anemometer
required
Notes
Illustration
issue date November
PAGE: 42
5.1 LIGHTING EQUIPMENT SCHEDULE (SUMMARISED)
6. ARCHITECTURAL LIGHTING CONTROL
6.1 Kuwait Trade Centre : Lighting Control
Show Descriptions
1 System Description:
The system shall be supplied as defined in the detailed performance specification.
2 Show overview:
2.1 The lighting control system shall allow for programmable and variable lighting effects. This document provides a
description of the initial shows required but shall not be construed as to limit the system capability to providing these
shows only.
2.2 The daily show sequence will commence at a time determined by an astronomical time clock integral with the system,
typically this will be 30 minutes before sunset. Shows will stop at an absolute time determined by the time clock, typically
01.00 hours. Thereafter an overnight static scene will be set that will be switched off at a time relative to sunrise, typically
30 minutes after sunrise. This setting will prevent operation of heat sensitive lighting components throughout the daylight
hours.
2.3 Event shows shall be required to be initiated by time clock and calendar and by manual operation. These will similarly
be limited to operating in the hours of darkness only. These shows will be variable year on year by selection of preprogrammed shows or by providing new programmes as and when required.
3 Daily Show:
3.1 The daily show will be initiated by time clock events and will consist of a sunset show, an evening show an overnight
scene and a sunrise show.
3.2 The sunset show will typically consist of a white scene that fades up over 5 minutes at a given time then a subsequent
fade of 20 minutes to a blue scene including set up of interior night scenes and water feature effects chases
3.3 The evening show shall consist of between 25 and 50 scenes that consecutively change colour floor by floor. These
scenes shall be selected according to inputs from a roof mounted ultrasonic anemometer to indicate, by the number of
floors in each colour the measured wind speed. The system shall be programmed with at least four alternate patterns that
may be selected manually or by wind direction information from the anemometer.
3.4 Typically the anemometer shall provide an RS232 output as an ASCII string that shall include comma separated
variables including the wind speed and the wind direction. Wind speed data will be used to select specific scenes, wind
direction data may be used to determine the groups of scenes selected by the wind speed data.
3.5 Typically the scenes shall have a fade time of 3 to 5 seconds and a wait time of 5 to 10 seconds, these values will
be finally determined during set up of the system. Scene selection shall be initiated by the last data received from the
anemometer at the completion of the previous scene wait time.
3.6 Response to wind speed shall be non linear. Typically from 0m/s to 12m/s scenes are selected each 1m/s change in
wind speed. Thereafter scenes shall be selected at 14m/s, 16m/s, 18m/s, 20m/s, 23m/s, 26m/s, 30m/s, 34m/s, 38m/s, 44m/s,
50m/s 58m/s, >66m/s . These values are based on average ground level data and shall be able to be reset as required
based on actual performance of the anemometer on the building. Further information as to actual wind speeds shall be
available in the course of construction. Final settings shall be determined during on site set up.
3.7 The overnight scene shall consist of all floors in a single colour. This scene shall be selected at a determined time that
may be altered as required. At sunrise the show shall be the exact inverse of the sunset show.
4 Event Shows:
4.1 Event shows shall include sequences of colour change on tower and atrium lighting elements. These shall be
sequences of 100 cues that loop and repeat or may alternitavely be similarly sized chase sequences. Chase patterns be
established with the possibility of varying colours in the cue sequence on the fly using a separate sequence to determine
order and change of the colours. Speed and timing of sequences shall be variable. It shall be possible to use input from the
anemometer to determine speed and colour selection in the sequences from either wind speed or direction information.
4.2 Event shows shall typically replace the daily shows on given calendar days and by manual selection either on the day
the effect is required or to interrupt and replace the daily show running.
5 Housekeeping Shows:
5.1 Housekeeping scenes and shows shall be provided for fault finding. These scenes shall be manually selected and
password protected.
5.1 All Red, All Green and All Blue scenes shall be required. A red green blue chase of 1 second fade and 3 second with
per scene shall be required. An All On scene shall be required.
5.2 Test scenes or other outputs shall be required to confirm the anemometer is functioning and is being correctly
interpreted by the system for wind speed and direction.
6 Programming:
6.1 The system supplier shall provide all system elements and shall confirm compatibility and operation by off site tests
and mock ups prior to shipping equipment to site
6.2 The system supplier shall work with the Lighting designer to prepare agreed formats for “story boards” covering daily
shows and initial event shows. These shows shall be off-site programmed as will initial settings for other presets, effects
and scenes as required.
6.3 On site programming will include initial system set up and testing, loading and testing of off-site programming. The
programmer shall work with the lighting designer to fine tune shows to the satisfaction of the client’s representative.
Kevan Shaw 9-12-04
6.2 CIRCUIT SCHEDULE
6.2 SCHEMATIC DMX CONTROL DIAGRAM
7. LIST OF SPECIFIED MANUFACTURERS AND SUPPLIERS
Download