MANTECH INC. 2 Admiral Place, Guelph, Ontario, Canada N1G 4N4 P: (519) 763-4245 Fax: (519) 763-9995 www.mantech-inc.com PeCOD COD Analysis Testing Soaps and Detergents www.mantech-inc.com Load. Start. Done. Page 1 of 4 info@mantech-inc.com MANTECH INC. 2 Admiral Place, Guelph, Ontario, Canada N1G 4N4 P: (519) 763-4245 Fax: (519) 763-9995 www.mantech-inc.com PeCOD Conclusions and Advantages PeCOD rapid analysis will provide soap and detergent manufacturers with a fast and accurate indication of the organic content in their waste. Samples containing approximately 3% surfactants in water with extremely high COD were analyzed. With a large initial dilution of the sample with water (1000x), they were easily introduced to the PeCOD without any foaming issues. PeCOD results correlated extremely well with dichromate results, with small discrepancies due only to sampling differences. Optimal results for PeCOD analysis will be achieved using a 1000-fold dilution and analyzing in the red or yellow electrolyte range. PeCOD is a green technology that allows soap and detergent manufacturers to market this as an improvement over an older, toxic test and will provide valuable information on the biological footprint of fire suppressants. It also promotes green initiatives within the company. Background The PeCOD is a new technology that allows for fast, green and accurate determination of COD. PeCOD is designed to test various waste samples from manufacturing and municipal sources to determine COD load. Three different samples were received from a soap and detergent manufacturer. These samples were analyzed by both the dichromate and PeCOD COD Methods by MANTECH INC. PeCOD Testing Sample 1 was a liquid sample, however very foamy in nature. Samples 2 and 3 were extremely viscous, the consistency of liquid hand soap. All samples were diluted 1000-fold, sample 1 by volume and samples 2 and 3 by weight. The samples were then allowed to settle. Sampling for both the dichromate and PeCOD tests occurred from the same diluted sample container. www.mantech-inc.com Load. Start. Done. Page 2 of 4 info@mantech-inc.com MANTECH INC. 2 Admiral Place, Guelph, Ontario, Canada N1G 4N4 P: (519) 763-4245 Fax: (519) 763-9995 www.mantech-inc.com Results Sample Info Sample Name: Range (B, G, Y, R): Dilution Factor: Sample Name: Range (B, G, Y, R): Dilution Factor: Sample Name: Range (B, G, Y, R): Dilution Factor: Sample Name: Range (B, G, Y, R): Dilution Factor: 1 Yellow 1000 2 Yellow 1000 3 Yellow 1000 1:1 mixture of samples #1 and 3 Yellow 1000 Replicate 1 2 AVERAGE 1 2 AVERAGE 1 2 AVERAGE 1 2 AVERAGE PeCOD® Results 217300.0 216100.0 216700.0 772500.0 793900.0 783200.0 610800.0 608700.0 609750.0 453200.0 449100.0 451150.0 Dichromate Results 292000.0 271000.0 281500.0 788000.0 766000.0 777000.0 713000.0 715000.0 714000.0 468000.0 491000.0 479500.0 The first sample is composed of diethylene glycol monobutyl ether, which is very soluble in water. A good correlation is observed for both COD measurement techniques. www.mantech-inc.com Load. Start. Done. Page 3 of 4 info@mantech-inc.com MANTECH INC. 2 Admiral Place, Guelph, Ontario, Canada N1G 4N4 P: (519) 763-4245 Fax: (519) 763-9995 www.mantech-inc.com The second sample contains diethylene glycol monobutyl ether, ethylene glycol and lauryl alcohol. While both glycols are soluble in water, lauryl alcohol is not. It is however soluble in ethylene glycol. An excellent correlation is observed between PeCOD and dichromate. The third sample contains lauryl alcohol and propylene glycol. A good correlation is observed for both COD measurement techniques, with differences likely due to sampling errors caused by the insolubility of lauryl alcohol in water. In an attempt to remove some error due to sample matrix difficulties, a 1:1 mixture of sample 1 and 3 was analyzed, as the glycol from sample 1 should help dissolve some of the lauryl alcohol in sample 3. A good correlation was observed between PeCOD and dichromate. Summary of PeCOD Benefits PeCOD is a Safe and Green Technology. PeCOD analysis is conducted with a non-hazardous electrolyte while the dichromate COD test requires harmful chemicals including potassium dichromate, mercuric sulfate and sulfuric acid. PeCOD promotes safe and healthy working environments and contributes to green initiatives. The MANTECH PeCOD analyzer is accurate and precise. It generates results within +/-10% of the theoretical COD value. Accredited bodies such as Standard Methods state that the dichromate COD method yields results within +/- 20% of the theoretical value. Immediate savings can be realized as the average PeCOD sample costs approximately $1.00. This includes the cost of blanks, calibrants and sensors, with no disposal costs required. Vials purchased for dichromate testing have an average cost of $1.25 each, plus disposal costs associated with hazardous waste. Total estimate cost for the dichromate test is $3.00 per sample. PeCOD provides a real time analysis of COD in approximately 6-15 minutes. This real time quick analysis aides in the regulation of product losses, waste stream COD loads and treatment plant optimization in order to troubleshoot problems while reacting quickly and precisely to changes in the system. The MANTECH PeCOD is a rugged, durable instrument generating accurate and precise results that stand the test of time. www.mantech-inc.com Load. Start. Done. Page 4 of 4 info@mantech-inc.com