TO REMCOR TJ40.TJ80 –A, AB, ABC DISPENSER

advertisement
Remcor Incorporated
500 Regency Drive
Glendale Heights, IL 60139
Telephone (708) 980-6900
Facsimile (708) 980-8511
FOR CONNECTING WHRILPOOL TRANSTEC IIR ICEMAKER
TO REMCOR TJ40.TJ80 –A, AB, ABC DISPENSER
(refer to installation drawing attached)
1. Install gasket in feed tube hole in hopper shown.
2. Push the ice feed tube up through the cabinet opening into the hopper, and lower it onto the icemaker
nozzle.
3. Shift the icemaker position slightly as necessary for proper feed tube alignment. Permanently fasten the
icemaker according to manufacturers instructions.
4. Check feed tube extension inside hopper, and remove and cut of necexxary to botain 1” extension.
5. Measure insulation length required between top of icemaker cabinet and bottom of foam insulation inside
dispenser. Cut insulation 1” longer than measured length.
6. Slide insulation towerds top of edd tube, and install feed tube on icemaker nozzle using clamp provided.
7. Follow installation instructions provided with icemaker and dispenser.
1
90634
FIGURE 1. INSTALLATION
ROUTE ICEMAKER
BULB AS SHOWN
DETAIL
“B”
DISPENSER
DISPENSER
INSULATION
DETAIL
“A”
ICEMAKER
ICEMAKER
È
È
É
ÉÉ
È
È
É
ÉÉ
ÉÉ
ÉÉ
É
ÈÈ
ÉÉ
ÈÈ
FEED
TUBE
GASKET
SEAL
WITH
RTV
HOPPER
DETAIL “B”
90634
2
STAINLESS
DEFLECTOR
ICEMAKER
BULB – TOP
AGITATION
BULB –
BOTTOM
END OF INSTALLED
BULB PROTRUDES
APPROX 1/4” TYPICAL
ALUMINUM
PLATE
FIGURE 2. DEFLECTOR ASSEMBLY
DEFLECTOR ASSEMBLY
INSTALL BARE BULBS
AS SHOWN ABOVE
AGITATION BULB
ICEMAKER BULB
WITH INSULATION
TUBING UP TO
DEFLECTOR
INSULATING TUBING
UP TO DEFLECTOR
FIGURE 3. HOPPER INTERIOR
3
90634
Download