New Muon Lifetime and the Fermi Coupling Constant GF Kevin Giovanetti James Madison University HallC meeting, JLAB, Aug 10, 2007 aµ = (gµ − 2) /2 Precision Muon Phyiscs FUNDAMENTAL SYMMETRIES Precision Measurements of Standard “Of all the recent muon experiments, the measurement of the “The weak mixing angle θW, parametrizes the mixing Model Properties “The Fermi constant, , measured via thebyµ+ lifetime muon anomalous magnetic moment, experiment µ-2)/2bosons U(1)aYµ=(g gauge in the between neutral SU(2)GL Fand Precision Measurements E821be atElectroweak BNL stands out experimentally and theoretically. “ “High precision electroweak experiments provide will improved aboth factor of 20 PSI. That Standard Model. Itby is, arguably, theatmost important stringent of the Model (SM) at the current tree and parametertests is used to Standard normalize all When weak charged parameter in electroweak physics. combined with “That measurement was statistics limited and could be further quantum loop levels.” and most measurements weak neutral current amplitudes. Itconstant) is also and precision of a, G (the Fermi F improved. Indeed, an upgrade proposal by the collaboration instrumental for comparison with and other precision , it can be used to probe quantum loop corrections m outlines a plan to reduce the error in by a about factor of 2.” from Z electroweak measurements.” heavy fermions, the Higgs scalar, and various new physics effects.” HallC meeting, JLAB, Aug 10, 2007 aµ = (gµ − 2) /2 Precision Muon Phyiscs FUNDAMENTAL SYMMETRIES MUONS PSI TRIUMF BNL FNAL ? Michel parm Lifetime µ−p capture µ−d capture g-2 µA->eA ρ, δ, η, Pµξ GF (1 ppm) ΛS -> gP L1A SUSY, BSM LFV, BSM HallC meeting, JLAB, Aug 10, 2007 MUON Physics Physical Review Letters, 20 July 2007,Volume 99, Number 3 Improved Measurement of the Positive-Muon Lifetime and Determination of the Fermi Constant D. B. Chitwood et al. (MuLan Collaboration) Published 16 July 2007 Measurement of the Muon Capture Rate in Hydrogen Gas and Determination of the Proton's Pseudoscalar Coupling gP V. A. Andreev et al. (MuCap Collaboration) Published 16 July 2007 032002 Electroweak Radiative Corrections to Muon Capture Andrzej Czarnecki, William J. Marciano, and Alberto Sirlin Published 16 July 2007 032003 HallC meeting, JLAB, Aug 10, 2007 Standard Model Electroweak Interaction (4 parameters) g’ U(1) g SU(2) MH (Higgs) v expectation value of the Higgs field α Fine structure constant 00.045 ppm GF Fermi coupling constant 09.000 ppm Mz Mass of the Z boson 23.000 ppm MH Higgs mass constrained mi masses of quarks and leptons (12) CKM quark mass mixing matrix, [Cabbibo] Kobayashi-Maskawa (4) MKS mass matrix for neutrinos, Maki-Nakagawa-Sakata matrix (4) Cosmological Constant (1) QCD Coupling (1) 26 dimensionless constants for standard model •Ritenbergen and Stuart, Nucl. Phys. B564 (2000) •PDG, Particle Data Group Electroweak Interaction e νµ µ+ µ + → e+ + ν e + ν µ νµ + νe µ+ e+ νe W+ 2 2GF ( LF = − u (ν e )γ α (1 − γ 5 )u ( e + ) )(u (ν µ )γ β (1 − γ 5 )u( µ + ) ) 4 kα kα − gαβ + 2 2 g MW + + β α ( ν γ γ µ LW = − (u (ν e )γ (1 − γ 5 )u ( e ) ) 2 u ( ) ( 1 − ) u ( )) 5 µ 2 8 k − MW gαβ g2 + α LW = − (u (ν e )γ (1 − γ 5 )u ( e ) ) 2 (u (ν µ )γ β (1 − γ 5 )u ( µ + ) ) 8 MW Fermi Coupling constant 2 F 55 11 G mµµ = ((11++ δ ) 33 ττ 192π νµ µ + νe + e γ +… νµ GF g 22 (1 ++ ∆r) = 22 2 8M WW µ+ Z0 W+ e+ +… νe The theoretical uncertainty on GF as extracted from the muon lifetime is < 0.3 ppm. ELectroweak • Basic parameters [2006] (e.g. PDG) Standard Model Electroweak Interaction α Fine structure constant 00.045 ppm GF Fermi coupling constant (Before current effort) 09.000 ppm Mz Mass of the Z boson δGF GF = 1 δτ − 2 τ 9 ppm 5 δmµ − 2 mµ 0.08 ppm 23.000 ppm 1 δ (1 + q) − 2 (1 + q) 0.3 ppm MuLan Collaboration University of Illinois at Urbana Champaign (UIUC) Boston University (BU) University of California, Berkeley (UCB and LBNL) University of Kentucky, Lexington TRIUMF, Vancouver James Madison University, (JMU) KVI Groningen, Netherlands HallC meeting, JLAB, Aug 10,University, 2007 Istanbul Technical Turkey HallC meeting, JLAB, Aug 10, 2007 The experimental concept Number (log scale) Real dataKicker On Measurement Period time Fill Period 5 -12. kV kV 12.5 Rates • 1ppm requires at least 1012 observed decays • Probability for a set of measurements (t1, t2,…) dP(t1 , t2 ... | τ ) = ρ ( t1 | τ ) ρ ( t2 | τ )...dt1dt2 ... • Probability that a parameter has a value based on (t1, t2,…) L(τ | t1 , t2 ...) = ρ ( t1 | τ ) ρ ( t2 | τ ) Rates and Uncertainty • For a simple distribution one can find the value for τ that make the experimental result highly probable and estimate the uncertainty. (same result from fitting) dL(τ | t1 , t2 ...) =0 dτ t 1 −τ ρ (t ) = e τ t1 + t2 + ... τ= N 1 ∂ρ 2 ∫ dt ρ ∂τ ∆τ = N ∆τ = τ N − 1 2 Uncertainty with Background Assume measurement period of 10τ . 001-.002 Uncertainty • Uncertainty is increased due to new terms in the distribution • Lifetime is distorted due to an incorrect distribution •The average is no longer an unbiased estimator for the lifetime when there is background •Reduce your uncertainty through statistics therefore an unbiased measurement of t is critical •Individual precise measurements are not critical KNOW YOUR DISTRIBUTION REMOVE SYSTEMTICS Rates • To accumulate the statistics necessary in a one month period – 4.0x105 muon decays/sec – 1 muon every 3 µs • Need more than 1 muon in target at a given time. – Granularity (FAST approach) – Pulsed beam (µLAN Approach) • Duty facor (35 µs -total ) /(5 µs –on) [factor of 7] – 3x106 muons/sec Beam rate of a FEW MHz MuLan Experiment at the Paul Scherrer Institut 1.8 mA cyclotron, Villigen, Switzerland 590 MeV protons Neutrons SINQ Swiss Light Source πe3 beamline Surface Muon Beam 29 MeV/c •Dedicated beam studies for several years •A Beam Rate > 11 MHz; •Spot at target, only few cm2. •Separator leaves about 5–10% positron background. •Many elements to tune. Straight beam is tricky. •Extinction fraction looks reasonable. (1000) quads kicker plates separator Expt. +12.5 kV 0 -12.5 kV 11.3 m triplet slits triplet Subsystem #1 PSI πE3 4.2 MeV muon source Quads Kicker Plates N S +10 kV 0 -10 kV Kicker HV supply; 50 kHz cycle time Subsystem #2 Subsystem #6 LEDs Simulations: outer t Tunes inner GEANT 4 Systematics Fitting outer 500 MHz WFD Bank Online DAQ and Analysis Farm Subsystem #3 #4 Subsystem #3 inner e+ Subsystem #5 25 kV (+/- 12.5 on each plate) kick, 12 cm gap, 30 kHz: a gift from TRIUMF Extinction ~ 1000 Trigger Suppression Adjustable Accumulation Measuring Period 2-sided, soccer-ball geometry Hex-house Inner (larger) Outer (smaller) Pent-house ( ea Ar lse Pu ter ou ) 2 Analog Pulses Pulse Area (inner)