to the Pdf Air Driven Hydraulic Pumps

advertisement
Air Driven Pumps and Power Packs
KR & GX PUMPS
SUPPLYING PRESSURE TO INDUSTRY
The Company
HEYPAC is a world leader in the development,
manufacture and marketing of a range of the most
advanced air driven fluid pumps and hydraulic
power units.
The company was established in 1978 and since
then has developed a unique product line of
hydraulic equipment to satisfy industrial
requirements for "power on demand".
The rugged design and build quality of the range
can provide a cost effective and energy efficient
product for use with a variety of fluids in many
industrial, mobile and marine applications.
The GX and KR series includes a wide range of flow
and pressure options and can be supplied in either
basic pump form, complete with an integral
reservoir or as a fully assembled power unit.
The wide range of complimentary accessories
ensures that the GX and KR series pumps can be
tailored to fit a wide range of applications in the
most demanding conditions.
HEYPAC air driven fluid pumps and hydraulic
power units are designed and manufactured in the
United Kingdom, under a quality management
system approved by Lloyd's Register Quality
Assurance to ISO 9000.
HEYPAC products have been sold throughout the
world through our own associate companies and
authorized distributors, who operate in Europe,
North America, Africa, the Middle and Far East and
Australia. All associate companies and distributors
have been fully trained and are able to offer
application advice, local product availability, after
sales support and service facilities. Further details
are available on request or from the web site at
www.heypac.co.uk or www.heypac.com.
Contents
Principal Operation
Page 3
GX Range
Page 4
KR Range
Page 6
Sizes and Specifications
Page 8
Installation Considerations
Page 9
5"
5"
2"
2
)
Page 12
"
75
5.
Ordering Codes
=
Page 10
0
R8
(K
Custom Solutions
2"
Applications, Accessories and
Principal Operation
The HEYPAC is a double acting, free piston,
compressed air driven hydraulic pump of infinitely
variable delivery for general use wherever a
compressed air supply is available. The pump will
cycle automatically according to system demand
and stall under zero flow conditions with minimal
energy consumption. The output flow and
pressure depend upon the intensification ratio
relative to the air supply pressure and volume.
The air operated fluid pumps and hydraulic power
packs are currently available with fluid-to-air
pressure ratios from 2.5:1 to 80:1. All models
employ similar air drives with only the fluid end
varying in size to produce the different pressure
intensification ratios. Key areas of the pumps
construction and operation are described below.
AIR VALVE - a self reciprocating valve that
alternates the compressed air supply to the upper
and lower sides of the drive piston assembly
generating the pumping motion of the unit. A
unique system of pilot control produces positive
spool reversal.
AIR DRIVE - a lightweight drive piston complete
with self lubricating seals allows the pump to
operate on an unlubricated air supply.
PISTON ROD - transmits the compressed air power
to the fluid being pumped.
The cross sectional area of this piston in relation to
the air drive piston provides the pump
intensification ratio.
TRANSFER VALVE - is closed as the piston rises,
B via
drawing fluid into the lower pump chamber A
the suction valve and at the same time the piston
A to the
displaces fluid from the upper chamber A
system. When the pump reverses and the piston rod
begins to fall the suction valve is closed by the
increase in pressure in the lower chamber and the
transfer valve is opened. Fluid is then displaced
through the transfer valve to the upper chamber
where the excess fluid is again forced into the
system.
A
B
2"
SUCTION VALVE - opens to allow fluid to enter the
pump as the piston assembly rises.
5"
5"
2"
0
R8
(K
=
"
75
5.
)
3
Performance Graphs
GX
GX Range
Model
GX025 GX05
GX10
GX20
GX30
GX40
GX60
GX80
Ratio
fluid: air
2.5:1
5:1
10:1
20:1
30:1
40:1
60:1
80:1
P max-fluid
bar (psi)
17.5
(254)
35
(508)
70
(1015)
140
(2030)
210
(3045)
280
(4060)
420
(6090)
560
(8120)
Q max fluid
l.min (US gpm)
80
(21.1)
40
(10.6)
20
(5.3)
10
(2.6)
7.5
(1.98)
5.0
(1.3)
3.8
(1.0)
2.5
(0.66)
Q max avge fluid
l.min (US gpm)
22
(5.8)
11
(2.9)
5.5
(1.45)
2.8
(0.74)
2.1
(0.55)
1.4
(0.37)
1.0
(0.26)
0.7
(0.18)
* For definitions of Q Max and Q Max avge see 'Technical Data' section on page 7.
GX025
FLUID
PRESS.
AIR
PRESS.
bar (p.s.i)
FLUID
PRESS.
AIR
PRESS.
GX05
bar (p.s.i)
bar (p.s.i)
18 (261)
bar (p.s.i)
35 (508)
16 (232)
30 (435)
14 (203)
25 (363)
12 (174)
20 (290)
10 (145)
7 (100)
6 (87)
8 (116)
6 (87)
7 (100)
6 (87)
15 (218)
5 (73)
10 (145)
4 (58)
3 (44)
4 (58)
5 (73)
4 (58)
2 (29)
3 (44)
5 (73)
2 (29)
1.4 (20)
2 (29)
0
0
0
5
(1.3)
10
(2.7)
15
(4)
20
(5.3)
25
(6.7)
30
(8)
35
(9.3)
40
(10.7)
45
(12)
50
(13.3)
0
4
8
12
16
20
24
28
32
36
40
(1.06) (2.12) (3.17) (4.23) (5.29) (6.35) (7.40) (8.47) (9.52) (10.58)
L/min (US gpm)
FLUID
PRESS.
L/min (US gpm)
FLUID
PRESS.
AIR
PRESS.
GX10
bar (p.s.i)
AIR
PRESS.
GX20
bar (p.s.i)
bar (p.s.i)
80 (1160)
140 (2030)
70 (1015)
120 (1740)
60 (870)
bar (p.s.i)
100 (1450)
50 (725)
80 (1160)
40 (580)
7 (100)
6 (87)
5 (73)
30 (435)
4 (58)
4 (58)
20 (290)
40 (580)
3 (44)
2 (29)
10 (145)
7 (100)
6 (87)
5 (73)
60 (870)
3 (44)
2 (29)
1.4 (20)
20 (290)
1.4 (20)
0
0
0
0
2
4
6
8
10
12
14
16
18
20
(0.53) (1.06) (1.59) (2.12) (2.64) (3.17) (3.70) (4.23) (4.76) (5.29)
1
2
3
4
5
6
7
8
9
10
(0.26) (0.53) (0.79) (1.06) (1.32) (1.59) (1.85) (2.12) (2.38) (2.64)
L/min (US gpm)
FLUID
PRESS.
L/min (US gpm)
FLUID
PRESS.
AIR
PRESS.
GX30
bar (p.s.i)
AIR
PRESS.
GX40
bar (p.s.i)
bar (p.s.i)
200 (2900)
bar (p.s.i)
300 (4350)
180 (2610)
250 (3625)
160 (2320)
140 (2030)
200 (2900)
120 (1740)
100 (1450)
80 (1160)
60 (870)
40 (580)
7 (100)
6 (87)
150 (2175)
7 (100)
6 (87)
5 (73)
5 (73)
4 (58)
3 (44)
100 (1450)
4 (58)
3 (44)
50 (725)
2 (29)
20 (290)
2 (29)
1.4 (20)
1.4 (20)
0
0
3
(0.79)
4.5
(1.19)
6
(1.59)
0
7.5
(1.98)
L/min (US gpm)
1
(0.26)
2
(0.53)
3
(0.79)
2"
L/min (US gpm)
5"
5"
2"
"
75
5.
)
4
=
1.5
(0.40)
0
R8
(K
0
4
(1.06)
5
(1.32)
GX Range continued
GX
FLUID
PRESS.
FLUID
PRESS.
AIR
PRESS.
GX60
bar (p.s.i)
AIR
PRESS.
GX80
bar (p.s.i)
bar (p.s.i)
bar (p.s.i)
600 (8700)
400 (5800)
350 (5075)
500 (7250)
300 (4350)
400 (5800)
250 (3625)
7 (100)
6 (87)
5 (73)
4 (58)
200 (2900)
300 (4350)
150 (2175)
7 (100)
6 (87)
5 (73)
200 (2900)
3 (44)
4 (58)
100 (1450)
3 (44)
2 (29)
1.4 (20)
100 (1450)
2 (29)
50 (725)
1.4 (20)
0
0
0
0.75
(0.20)
1.5
(0.40)
2.25
(0.60)
3
(0.79)
3.75
(0.99)
0
0.5
(0.13)
1
(0.26)
1.5
(0.40)
2
(0.53)
2.5
(0.66)
L/min (US gpm)
L/min (US gpm)
Dimension Diagrams
Other Option Dimensions :-
'OO' - As T1 but without Flange
'W1' - As R2 but without Reservoir
'R1' - As R2 but Reservoir Ø 152 (6”)
Type 'R2'
207
'R3' - As R1 but for horizontal mounting
(6")
'R4' - As R2 but for horizontal mounting
152
(0.9")
Ø
(8.1")
22
105
(4.1")
*For GX025
add 26mm. (1.0’’)
(4.6")
Type 'T1'
**For GX025 add 60mm. (2.4’’)
(3.7")
*117
94
Manifold
('M' Option Only)
**186
(7.3")
Fluid Outlet
Ports A & B
'A'
Tank Mounting Flange
(Gasket Supplied)
227
(8.9”)
28 (1.1’’)
GX05
97 (3.8’’)
GX10
80 (3.2’’)
GX20<80
71 (2.8’’)
Side View
Air Exhaust (E)
165
100 (3.9")
Air Inlet (N)
(6.5")
Alternative
Fluid Outlet Port
Fluid Return (T)
Cutout Ø140 (5.5")
required in tank lid
Seal Drain
1/8" BSPT
(14.4")
(3.1")
Dimension ‘A’
GX025
Suction Port
Side View
Mounting Bolts
4 x M10
367
80
Model
Mounting Holes
4 x Ø 11 (0.45")
Fluid Outlet (P)
Mounting Holes
4 x Ø 11 (0.45")
Fluid Return
to Reservoir
❑ 85
(3.3")
Allow extra 180 mm (7")
for Reservoir removal.
110
Ø
205
(4.3")
❑ 124
(8.1")
(4.9")
View from beneath Pump
showing Mounting Details
2"
Rear View
5"
5"
2"
0
R8
(K
=
"
75
5.
)
5
Performance Graphs
KR Range
KR20
FLUID
PRESS.
KR05
Model:
KR10
KR20
KR40
KR80
AIR
PRESS.
bar (p.s.i)
bar (p.s.i)
KR
160 (2320)
Ratio
fluid: air
5:1
10:1
20:1
140 (2030)
80:1
40:1
120 (1740)
P max-fluid
bar (psi)
42.5
(615)
85
(1230)
170
(2460)
340
(4920)
7 (100)
100 (1450)
680
(9840)
5 (73)
80 (1160)
60 (870)
Q max fluid
l.min (US gpm)
10
(2.65)
5
(1.32)
2.5
(0.65)
1.2
(0.32)
0.6
(0.16)
Q max avge fluid
l.min (US gpm)
2.8
(0.74)
1.4
(0.37)
0.7
(0.18)
0.35
(0.09)
0.17
(0.04)
3 (44)
40 (580)
20 (290)
1.5 (22)
0
0
0.5
(0.13)
1
(0.26)
FLUID
PRESS.
AIR
PRESS.
KR05
2
(0.53)
2.5
(0.66)
3
(0.79)
l/min (US gpm)
* For definitions of Q Max and Q Max avge see 'Technical Data' section on page 7.
bar (p.s.i)
1.5
(0.40)
FLUID
PRESS.
AIR
PRESS.
KR40
bar (p.s.i)
bar (p.s.i)
bar (p.s.i)
300 (4350)
35 (508)
30 (435)
7 (100)
250 (3625)
7 (100)
25 (363)
200 (2900)
5 (73)
20 (290)
150 (2175)
5 (73)
15 (218)
3 (44)
100 (1450)
10 (145)
3 (44)
1.5 (22)
50 (725)
5 (73)
1.5 (22)
0
0
0
2
(0.53)
4
(1.06)
6
(1.59)
8
(2.12)
0
10
(2.64)
0.2
(0.05)
0.4
(0.10)
0.8
(0.21)
1
(0.26)
1.2
(0.32)
l/min (US gpm)
l/min (US gpm)
FLUID
PRESS.
0.6
(0.16)
AIR
PRESS.
KR10
bar (p.s.i)
FLUID
PRESS.
AIR
PRESS.
KR80
bar (p.s.i)
bar (p.s.i)
80 (1160)
bar (p.s.i)
600 (8700)
70 (1015)
500 (7250)
60 (870)
7 (100)
400 (5800)
50 (725)
7 (100)
40 (580)
5 (73)
300 (4350)
5 (73)
30 (435)
200 (2900)
3 (44)
100 (1450)
1.5 (22)
3 (44)
20 (290)
10 (145)
1.5 (22)
0
0
3
(0.79)
4
(1.06)
5
(1.32)
6
(1.59)
0
l/min (US gpm)
0.2
(0.05)
0.4
(0.10)
2"
l/min (US gpm)
5"
5"
2"
)
6
"
75
5.
2
(0.53)
=
1
(0.26)
0
R8
(K
0
0.6
(0.16)
Dimension Diagrams
Model T2
124 (4.9”)
62 (2.45”)
Air Exhaust Ports
156 (6.2”) ( KR80 = 146 (5.75"))
Other Option Dimensions :-
124 (4.9”)
211 (8.3”) ( KR80 = 177 (7"))
R5 - As R5M but without Manifold
42 (1.7”)
KR
'OO' - As T2 but without Flange
Fluid Outlet
4 Holes Ø 11 (0.45”)
Air Inlet
150 (5.9”) ❑SQ
Fluid Suction
114 (4,5")
17,5 (0,7")
Model R5M
70 (2.8”)
99 (3,9")
Fluid Outlet
(A/B Port)
Model W2
114 (4,5")
Fluid Return
Port
140 (5,5")
30 (1,2") ( KR80 = 20 (0.8"))
9,5 (0,4")
( KR80 = 170 (6.6"))
99 (3.9”)
Air Inlet
211 (8.3”)
308 (12,1")
155 (6,1")
Fluid Outlet
Non 'M' Option
Plugged on 'M'
Option
52 (2")
70 (2.8")
17.5 (0,7")
Air Breather
149 (5.9”) ( KR80 = 140 (5.5"))
Valve Mounting Interface
ISO 4401-03
192 (7,6")
145 (5,7")
Fluid Outlet
4 Holes Ø 7 (0.28")
Fluid Suction
Technical Data
Minimum air pressure
GX and KR series - 1.4 bar (20 psi)
Air consumption
For details on air consumption please contact HEYPAC or your
local distributor.
Fluid temperature range
Minus 5 deg C to plus 70 deg C
Maximum hydraulic power
GX series - 1.5 kW (2.0 hp)
KR series - 0.37kW (0.5 hp)
“Q max."
Is defined as the maximum pump flow at 500
cycles/minute - intermittent duty only.
Maximum cycle speed
500 cycles/minute (intermittent).
For continuous duty maximum cycle speed should be reduced
to approx. 50 - 60 cycles/minute.
Applications involving continuous pumping should be referred
to HEYPAC.
2"
KR series - 8.5 bar (125 psi)
5"
5"
2"
=
"
75
5.
)
7
0
R8
(K
Maximum air pressure
GX series - 7.0 bar (100 psi)
“Q max. avge"
Is defined as the maximum average allowable flow over
complete system operating cycle including both periods of
pressure holding (stall condition) and fluid delivery.
Port Thread Sizes
GX Range
Fluid Outlet
Air
Fluid
M Option
Inlet
Outlet
BSP
SAE
Fluid
Fluid
Fluid Outlet
Outlet
Outlet
BSP
SAE
AirAir InletAir
Inlet
Inlet
BSP
SAE
Model: OO, T1, W1
Fluid
Fluid
Fluid Suction
Suction
Suction
BSP
SAE
GX025
2" NPT
2" NPT
G 1"
1" NPT
N/A
N/A
N/A
N/A
G 3/4"
3/4" NPT
GX05
G 2"
2" NPT
G 3/4"
12 SAE
N/A
N/A
G 1/2"
N/A
G 3/4"
3/4" NPT
GX10
G 1 1/2"
1 1/2" NPT
G 3/4"
12 SAE
N/A
N/A
G 1/2"
8 SAE
G 3/4"
3/4" NPT
GX20/30/40
G 1"
16 SAE
G 1/2"
8 SAE
G 3/8"
6 SAE
G 1/2"
8 SAE
G 3/4"
3/4" NPT
GX60/80
G 1"
16 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/4"
3/4" NPT
Alternative Outlet
Fluid Return
Model: R1, R2, R4
BSP
SAE
GX05
N/A
N/A
G 3/4"
12 SAE
N/A
N/A
G 3/4"
12 SAE
G 3/4"
3/4"NPT
GX10
N/A
N/A
G 3/4"
12 SAE
N/A
N/A
G 3/4"
12 SAE
G 3/4"
3/4"NPT
GX20/30/40
N/A
N/A
G 1/2"
8 SAE
G 3/8"
6 SAE
G 1/2"
8 SAE
G 3/4"
3/4"NPT
GX60/80
N/A
N/A
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/4"
3/4"NPT
KR Range
Model: OO, R5, T2, W2
Fluid
Fluid
Fluid Suction
Suction Suction
BSP
SAE
Fluid Outlet
Fluid
Fluid
M Option
Outlet
Outlet
SAE
BSP
Fluid
Fluid
Fluid Outlet
Outlet
Outlet
SAE
BSP
Fluid Return
Fluid
Fluid
R5 Only
Outlet
Outlet
SAE
BSP
AirAir InletAir
Inlet
Inlet
BSP
SAE
KR05
G 1"
16 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
3/8" NPT
KR10
G 1"
16 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
3/8" NPT
KR20
G 1"
16 SAE
G 1/4"
4 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
3/8" NPT
KR40
G 1"
16 SAE
G 1/4"
4 SAE
G 3/8"
6 SAE
G 3/8"
6 SAE
G 3/8"
3/8" NPT
KR80
G 1"
16 SAE
G 1/4"
4 SAE
N/A
N/A
G 3/8"
6 SAE
G 3/8"
3/8" NPT
2"
SAE Thread Designation
5"
5"
2"
0
R8
(K
=
"
75
5.
)
8
SAE
Thread
16 SAE
1 5/16’’ - 12UN-2B
12 SAE
1 1/16’’ - 12UN-2B
8 SAE
3/4’’ - 16UNF-2B
6 SAE
9/16’’ - 18UNF-2B
4 SAE
7/16’’ - 20UNF-2B
Installation Considerations
The HEYPAC GX and KR series
pumps are rugged and high
quality products and their long
service life can be increased by
correct installation.
Filtration
Suction strainers (125 or 40 micron
depending on model) are supplied
in all units fitted with a reservoir
but not included with 00, T and W
configuration pumps.
Additional system filtration to 25
micron or better is recommended.
An extended suction tube kit,
complete with suction strainer, can
be supplied for T configuration
pumps that are to be tank
mounted.
Fluids
The pumps will handle a wide range of fluids including those
with little or no lubricating properties.
Air supply - an auto drain
filter/regulator (25 micron) should
be fitted as close as possible to the
air inlet and be of sufficient size
for the air consumption
anticipated. The air drives of the
pumps are greased on assembly
and therefore should not be used
on lubricated air supplies as this
will wash out the grease and
shorten service life.
Fluids which have been satisfactorily pumped include:
Mineral Oils
Vegetable Oils
High water-based fluids
Water Glycol solutions
Water in Oil emulsions
Phosphate Esters
Silicate Esters
Grease
Liquified Gases
Water (For applications involving water, the option W should be
inserted in the pump model number).
Valves and Sytem Components
Due to HEYPAC's ability to maintain pressure at zero flow,
consideration should be given to fitting ultra low or no leakage
valves, such as poppet construction, and by so doing, the pump
will be protected from excessive cycling. A range of suitable
valves are available.
Mounting Orientation
Pumps can be mounted in any orientation with the exception
of all R configuration pumps. The R1, R2 and R5 models must
be mounted vertically with the reservoir beneath the pump
while the R3 and R4 models should be mounted horizontally.
2"
Flow Control
A suitable flow control must be used if the pump is to be
operated at or near maximum flow rate to prevent
overspeeding.
5"
5"
2"
0
R8
(K
=
"
75
5.
)
9
Accessories & Custom Solutions
Reservoir Kits
In addition to the integral R series of reservoirs
HEYPAC is able to offer larger reservoirs with 10 or
30 litre usable capacity suitable for mounting T1 or
T2 option pumps.
The reservoirs are epoxy powder - coated inside
and out and are supplied complete with fluid level
gauge, air breather/filler and pump suction tube
and strainer.
The 30 litre reservoir includes a return line filter as
standard, which is an optional extra on the 10 litre
reservoir. The 10 litre reservoir will accept a single
GX or KR series pump and the 30 litre reservoir will
accept single or twin pump installation from either
GX or KR series or a mix of both series.
A fluid level switch is an optional extra on either
size of reservoir. Larger capacity reservoirs are
available on request.
Manifold Options
The GX and KR series of pumps are available with
an integral manifold conforming to ISO standards
to enable the direct mounting of control valves.
The GX20 to GX80 and KR05 to KR40 pumps can be
supplied fitted with a manifold conforming to
ISO 4401-03-02-0-94 and the KR05 to KR40 pumps
can also be fitted with a manifold conforming to
ISO 4401-02-01-94.
The manifolds are available with both BSP and SAE
(UNF) service port threads.
System Accessories
Smoothing Kits to suppress the slight pressure
pulsations generated by the reciprocating pump
mechanism when perfectly smooth flow is required.
Fluid Level Switches for use with R1, R2, R5, 10
and 30 litre reservoirs to warn of low fluid level,
supplied complete with DIN connector.
2"
Return Line Filters 20 micron nominal rated for
use with GX20, 30 and 40 pumps when fitted to R1,
R2 and 10 litre reservoirs.
5"
5"
2"
0
R8
(K
=
"
75
5.
)
10
Valves
A wide range of directional control and pressure reducing
valves are available to suit all air driven pumps. The valves
have been selected for their no or ultra-low leakage
characteristics and are typically of poppet construction.
Directional Control Valves are available in 3 or 4 port
configurations for the control of single or double acting
cylinders or other diverting functions. The range of valve
operators include direct solenoid, in most popular voltages
and also an EEx rated option for explosive environments,
air pilot and lever operated. The valve mountings conform
to ISO 4401-03-02-0-94 and therefore the valve may be
directly fitted to all pumps with options M or M3 or on to
manifolds conforming to the ISO 4401-03-02-0-94
standard. The lever operated valve is also available in a
body ported version with 1/4" NPT port threads. The
solenoid and air operated valves are rated to a maximum
pressure of 315 bar while the lever operated valve is rated
to 400 bar. Maximum flow rates should not exceed 20
litres per minute.
Pressure Reducing Valves conforming to ISO 4401 are available in flange
or stackable mount configuration and compliment the directional valve
range. Maximum inlet pressure is 315 bar and five reduced pressure ranges
between 1 - 31.5 and 5 - 315 bar are available. Adjustment is by socket
head screw or hand knob.
Custom Solutions - While the standard range
of our air driven pumps covers a wide range of
applications we are always happy to look at
developing pumps for specific applications not
covered by standard products. In the past
specials have been produced for underground
mine operation, NACE approved units for sour
gas and pumps in stainless steel. If you should
have a special application then please contact
the technical staff at HEYPAC or your local
distributor who will be pleased to assist you.
Extended Suction Tube Kit including suction
strainer for use where basic pumps are being
installed in customer’s reservoir.
Noise Muffler Kit to reduce exhausting air noise
to a lower level than the standard exhaust silencer
fitted to every pump.
2"
Further details of all these accessories
are available from HEYPAC or your
local distributor.
5"
5"
2"
0
R8
(K
=
"
75
5.
)
11
GX40 B
S
N
00
Fluid/air pressure ratio:
GX025 - 2.5:1
GX05 - 5:1
GX20 - 20:1
GX30 - 30:1
GX60 - 60:1
GX80 - 80:1
M W DM**
GX10 - 10:1
GX40 - 40:1
Port threads:
N - NPT (GX025 only)
B - BSP
S - SAE (US Standard)
Dynamic fluid seals:
C - Carbon filled PTFE
S - Polyethylene
P - Polyurethane (Standard on GX40, GX60 and GX80)
O - Special options upon request
Static fluid seals:
N - Nitrile
V - Viton
E - EPDM Ethylene Propylene
Pump configuration:
00 - Basic Pump
T1 - As 00 Plus Tank Mounting Flange
W1 - As 00 Plus Wall Mounting Bracket
R1 - Power Pack Including 2.5 l Reservoir & Mounting Bracket
R2 - Power Pack Including 4.5 l Reservoir & Mounting Bracket
R3 - Horizontal Mounting Version of R1
R4 - Horizontal Mounting Version of R2
Manifold options:
M - Pump With ISO 4401-03-02-0-94
Manifold fitted (GX20 to 80 only)
Water option:
W - Pump for use with water (GX05 to 80 only)
Standard GX025 is water compatible
Design modifications:
DM** (e.g DM14 - Low Temperature Seals.)
Other options upon request
KR PUMP RANGE
GX PUMP RANGE
Ordering Information
KR40
B
P
V
00
M DM**
Fluid/air pressure ratio:
KR10 - 10:1
KR05 - 5:1
KR40 - 40:1
KR20 - 20:1
KR80 - 80:1
Port threads:
B - BSP
S - SAE (US Standard)
Dynamic fluid seals:
P - Polyurethane
C - Carbon Filled PTFE (US Standard)
Static fluid seals:
V - Viton (Standard)
E - EPDM Ethylene Propylene
Pump configuration:
00 - Basic pump
T2 - As 00 Plus Tank Mounting Flange
W2 - As 00 Plus Wall Mounting Brackets
R5 - 2.5 l Reservoir & Mounting Bracket
Manifold options:
M2 - Pump with
ISO 4401-02-01-0-94 Manifold Fitted
M3 - Pump with
ISO 4401-03-02-0-94 Manifold Fitted
(M Option not available on KR80)
Design modifications:
DM** (e.g DM27 - Liquid Gas Application Pump)
Other options upon request.
abcdef
If you require more information or assistance with ordering codes
please contact your distributor
GXKR10/01
HEYPAC LIMITED
Unit 3, The Royston Centre, Lynchford Road,
Ash Vale, Surrey GU12 5PQ
UK
Tel: +44 (0) 1252 511 003 Fax: +44 (0) 1252 519 003
Email: enquiries@heypac.co.uk
www.heypac.co.uk
HEYPAC INCORPORATED
1029 John R Road, Rochester Hills, MI 48307 USA
Tel: +1 248 652 3500 Fax: +1 248 652 1717
Email: answers@heypac.com
www.heypac.com
12