Engineering Specification SPEC, APPVL INST 505 IS BARRIER ATEX EB-20012676 Revision: A Number of Pages: 4 Comments: Originator: RCS 7/3/08 Approved: RCS 7/3/08 Rev ECN A 1035856 Description Release to Approvals Approval Date RCS 7/3/08 THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 1 of 4 S SPEC, APPV VL INST 50 05 IS BARR RIER ATEX X S Subject: Equipment type M Manufacture ed and submiitted for EB-200012676 Reevision A Model 505 IS Barrier and Leevel Shiftingg Power Sup pply Micro Motion, Incc. e examination A Address Bouldeer, Co. 803001, USA B Basis for exaamination Annex II of Directtive 94/9/EC C S Standard bassis EN 600799-0:2006 EN 600799-11:2007 EN 612411-0:2006 and EN N 61241-11:20055 C Code for type of protectiion Generaal requirements Intrinsiic safety ´i´ Dust Evvaluation "ibD". II (2) G [Ex ib] IIB B/IIC II (2) D [Ex ibD] THIS DOCUM MENT IS CONFIDENTIAL, CONTA AINS PROPRIETA ARY INFORMAT TION, AND SHOU ULD NOT BE DIS STRIBUTED, CO OPIED OR R W WITHOUT THE EXPRESS E WRITT TEN CONSENT OF O MICRO MOTION, INC. OTHERWISE REPRODUCED M Micro Motioon, Inc. Paage 2 of 4 SPEC, APPVL INST 505 IS BARRIER ATEX 1) EB-20012676 Revision A Subject and Type IS Barrier type 505 2) Description The Micro Motion model 505 is a DIN rail mount IS Barrier and signal isolator, meant to supply intrinsically safe power to the model 2200S Micro Motion Coriolis Transmitter (Reference BVS 08 ATEX E **** X) which can be connected to any Micro Motion Coriolis Flow Sensor. The model 505 also provides three port galvanic isolation as well as transmitting process variables to the Safe area side via 12-20mA input loop current signaling and HART communication. The 12-20mA signal from the Hazardous area (field) side is level shifted to 4-20mA on the Safe area (host) side. The model 505 has three sets of screw terminals: On the Hazardous area side, Loop Supply/mA/HART input. On the Safe area side, 18-42VDC power input and mA output/HART signaling. Hazardous area side and Safe area side are located on opposite sides of the model 505 plastic cabinet with more than 50mm between them. 3) Parameters 3.1 Non-intrinsically safe power supply circuit (terminals 11 – 12) - voltage - max. voltage Um DC DC 18-42 60 V V Non-intrinsically safe power and signal circuits (terminals 23 – 24) - max. voltage Um DC 60 V 3.2 3.3 Intrinsically Safe Output Circuit with type of protection Ex ib, for connection to a Micro Motion Model 2200S transmitter 3.3.1 Transmitter Supply circuit (terminals 1 - 2) - voltage - current - power 3.4 Uo Io Po DC 28 28 0,8 V mA W - for group IIC - max. external capacitance - max. external inductance Co Lo 80 30 nF mH - for group IIB - max. external capacitance - max. external inductance Co Lo 645 120 nF mH Ambient temperature range Ta -40 °C up to +60 °C THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 3 of 4 SPEC, APPVL INST 505 IS BARRIER ATEX 4) Marking 4.1 -40 °C ≤ Ta ≤ +60°C - type Model 505 IS Barrier EB-20012676 Revision A - type of protection 0575 5) Special conditions for safe use / Installation instructions 5.1 none II (2) G [Ex ib] IIB/IIC II (2) D [Ex ibD] THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 4 of 4