Subject:
Equipment type
M
Manufacture
ed and submiitted for
EB-200012676 Reevision A
Model 505 IS Barrier and Leevel Shiftingg Power Sup
pply
Micro Motion, Incc.
e
examination
A
Address
Bouldeer, Co. 803001, USA
B
Basis
for exaamination
Annex II of Directtive 94/9/EC
C
S
Standard
bassis
EN 600799-0:2006
EN 600799-11:2007
EN 612411-0:2006 and EN
N 61241-11:20055
C
Code
for type of protectiion
Generaal requirements
Intrinsiic safety
´i´
Dust Evvaluation
"ibD".
II (2) G [Ex ib] IIB
B/IIC
II (2) D [Ex ibD]
THIS DOCUM
MENT IS CONFIDENTIAL, CONTA
AINS PROPRIETA
ARY INFORMAT
TION, AND SHOU
ULD NOT BE DIS
STRIBUTED, CO
OPIED OR
R
W
WITHOUT
THE EXPRESS
E
WRITT
TEN CONSENT OF
O MICRO MOTION, INC.
OTHERWISE REPRODUCED
M
Micro
Motioon, Inc.
Paage 2 of 4
SPEC, APPVL INST 505 IS BARRIER ATEX
1)
EB-20012676 Revision A
Subject and Type
IS Barrier type 505
2)
Description
The Micro Motion model 505 is a DIN rail mount IS Barrier and signal isolator, meant to supply intrinsically safe
power to the model 2200S Micro Motion Coriolis Transmitter (Reference BVS 08 ATEX E **** X) which can be
connected to any Micro Motion Coriolis Flow Sensor. The model 505 also provides three port galvanic isolation as
well as transmitting process variables to the Safe area side via 12-20mA input loop current signaling and HART
communication. The 12-20mA signal from the Hazardous area (field) side is level shifted to 4-20mA on the Safe area
(host) side.
The model 505 has three sets of screw terminals: On the Hazardous area side, Loop Supply/mA/HART input. On the
Safe area side, 18-42VDC power input and mA output/HART signaling. Hazardous area side and Safe area side are
located on opposite sides of the model 505 plastic cabinet with more than 50mm between them.
3)
Parameters
3.1
Non-intrinsically safe power supply circuit (terminals 11 – 12)
- voltage
- max. voltage
Um
DC
DC
18-42
60
V
V
Non-intrinsically safe power and signal circuits (terminals 23 – 24)
- max. voltage
Um
DC
60
V
3.2
3.3
Intrinsically Safe Output Circuit with type of protection Ex ib, for connection to a Micro Motion Model 2200S
transmitter
3.3.1 Transmitter Supply circuit (terminals 1 - 2)
- voltage
- current
- power
3.4
Uo
Io
Po
DC
28
28
0,8
V
mA
W
- for group IIC
- max. external capacitance
- max. external inductance
Co
Lo
80
30
nF
mH
- for group IIB
- max. external capacitance
- max. external inductance
Co
Lo
645
120
nF
mH
Ambient temperature range
Ta
-40 °C up to +60 °C
THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR
OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC.
Micro Motion, Inc.
Page 3 of 4
SPEC, APPVL INST 505 IS BARRIER ATEX
4)
Marking
4.1
-40 °C ≤ Ta ≤ +60°C
- type
Model 505 IS Barrier
EB-20012676 Revision A
- type of protection
0575
5)
Special conditions for safe use / Installation instructions
5.1
none
II (2) G [Ex ib] IIB/IIC
II (2) D [Ex ibD]
THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR
OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC.
Micro Motion, Inc.
Page 4 of 4