Catalog of Products & Services 60 KESSLER TABLE HERMOMETER CORP. OF CONTENTS ISO 9002 REGISTERED ASTM THERMOMETERS ASTM CERTIFIED THERMOMETERS 11 - 19 24 - 29 FRACTIONAL DEGREE THERMOMETERS 31 - 33 LABORATORY THERMOMETERS 35 - 37 DEEP IMMERSION/VARI-IMMERSION 39 - 41 ENVIRONMENTAL CHAMBER 43 - 45 POCKET, MAXIMUM, SPECIALTY 47 - 49 JOINTED THERMOMETERS 51 - 53 GAUGING EQUIPMENT 55 - 59 ACCESSORIES CALIBRATION EQUIPMENT HYDROMETERS BI-METAL COMMENTARY 61 65 69 81 91 - 63 67 79 89 93 Page 7 For more information, please contact us: ExpotechUSA 10700 Rockley Road Houston, Texas 77099 USA 281-496-0900 [voice] 281-496-0400 [fax] E-mail: sales@expotechusa.com Website: www.ExpotechUSA.com CONVERSION SCALES THE CONVERSION TABLE MAY BE USED FOR CONVERTING DEGREES FAHRENHEIT TO DEGREES CENTIGRADE OR VICE VERSA. BOLD FACE NUMBERS IN THE CENTER REFER TO THE KNOWN TEMPERATURE IN EITHER CENTIGRADE OR FAHRENHEIT. EQUIVALENT TEMPERATURE IS FOUND IN THE APPROPRIATE LEFT OR RIGHT COLUMN. FORMULA FOR CONVERTING TEMPERATURE SCALES ABOVE 0 BELOW 0 O O TO CONVERT FAHRENHEIT READINGS TO CENTIGRADE: SUBTRACT 32 DEGREES AND DIVIDE THE REMAINDER BY 1.8. TO CONVERT FAHRENHEIT READINGS TO CENTIGRADE: ADD 32 DEGREES AND DIVIDE THE REMAINDER BY 1.8 TO CONVERT CENTIGRADE READING TO FAHRENHEIT: MULTIPLY BY 1.8 AND ADD 32 DEGREES TO THE RESULT. TO CONVERT CENTIGRADE READING TO FAHRENHEIT: MULTIPLY BY 1.8 AND SUBTRACT 32 DEGREES FROM THE RESULT. Page 9 ASTM THERMOMETERS Page 11 KESSLER’s rigid manufacturing tolerance and inspection ensure the production of ASTM thermometers that are well within the dimensional and accuracy specifications of E-1 and E-77 of the AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). To order a copy of test method E-77, please use catalog number ASTM E-77. PARTIAL IMMERSION ASTM 1C 1F 2C 2F 3C 3F IP CAT NO APPLICATION Partial Partial Partial Partial Partial TEMP RANGE DIV LENGTH IMMERSION 62C 62F 73C 1102 1104 1106 1108 1110 73F 1112 Partial Immersion 20 to 760OF 2 415mm 76mm CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION 1000 Acid Heat 30 to 220OF 1 375mm 152mm Immersion Immersion Immersion Immersion Immersion -20 to 150OC 0 to 302OF -5 to 300OC 20 to 580OF -5 to 400OC 1 2 1 2 1 322mm 322mm 390mm 390mm 415mm 76mm 76mm 76mm 76mm 76mm ACID HEAT ASTM 4C IP 1002 4F Acid Heat -1 to 105OC 0.5 375mm 152mm CLOUD AND POUR - LOW AND HIGH ASTM 5C 5F 6C 1C 1F 2C IP CAT NO 1006 1004 1010 Cloud & Pour, High Cloud & Pour, High Cloud & Pour, Low APPLICATION TEMP RANGE DIV LENGTH IMMERSION 6F 2F 1008 Cloud & Pour, Low -112 to 70OF 2 230mm 76mm -38 to 50OC -36 to 120OF -80 to 20OC 1 2 1 230mm 230mm 230mm l08mm l08mm 76mm DISTILLATION - LOW AND HIGH ASTM 7C 7F 8C IP 5C CAT NO 6C 8F 1014 1012 1018 APPLICATION Distillation, Low Distillation, Low Distillation, High TEMP RANGE DIV LENGTH IMMERSION 1016 Distillation, High 30 to 760OF 2 385mm total -2 to 300OC 30 to 580OF -2 to 400OC 1 2 1 385mm 385mm 385mm total total total PENSKY-MARTENS - LOW AND HIGH ASTM 9C 9F 10C 15C 15F 16C IP CAT NO 1022 1020 1026 Pensky-Martens Low Pensky-Martens Low Pensky-Martens High APPLICATION TEMP RANGE DIV LENGTH IMMERSION 10F 16F 1024 Pensky-Martens High 200 to 700OF 5 290mm 57mm CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION -5 to 110OC 20 to 230OF 90 to 370OC 0.5 1 2 290mm 290mm 290mm 57mm 57mm 57mm OPEN FLASH ASTM 11C 11F IP 28C 28F 1038 1036 Open Flash Open Flash -6 to 400OC 20 to 760OF 2 5 310mm 310mm 25mm 25mm DENSITY - WIDE RANGE (GRAVITY) ASTM 12C 12F IP 64C 64F CAT NO 1042 1040 Gravity Gravity -20 to 102OC -5 to 215OF 0.2 0.5 420mm 420mm total total LOSS ON HEAT ASTM 13C IP 47C CAT NO 1048A Loss on Heat 155 to 170OC 0.5 155mm total 1010 PARAFFIN WAX MELTING POINT ASTM 14C 14F IP 17C 17F CAT NO 1051 1050 APPLICATION Paraffin Wax Melt Pt. Paraffin Wax Melt Pt. 38 to 82OC 100 to 180OF 0.1 0.2 375mm 375mm 79mm 79mm 1102 1042 ASTM THERMOMETERS SOFTENING POINT ASTM 15C 15F 16C 16F IP 60C CAT NO 1056 1054 1060 1058 61C APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION Softening Pt. Low Softening Pt. Low Softening Pt. High Softening Pt. High -2 to 80OC 30 to 180OF 30 to 200OC 85 to 392OF 0.2 0.5 0.5 1 397mm 397mm 397mm 397mm total total total total SAYBOLT VISCOSITY ASTM 17C 17F 18C 18F 19C 19F 20C 20F 21C 21F 22C 22F IP CAT NO 1085 1066 1086 1067 1087 1068 1088 1069 1089 1075 1090 1076 23C 23F 24C 24F Viscosity Saybolt Viscosity Saybolt Say Vis & Reid Vapor Say Vis & Reid Vapor Viscosity Saybolt Viscosity Saybolt Viscosity Saybolt Viscosity Saybolt Viscosity Saybolt Viscosity Saybolt Say Vis & Oxy Stab. Say Vis & Oxy Stab. 19 to 27OC 66 to 80OF 34 to 42OC 94 to 108OF 49 to 57OC 120 to 134OF 57 to 65OC 134 to 148OF 79 to 87OC 174 to 188OF 95 to 103OC 204 to 218OF 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 275mm 275mm 275mm 275mm 275mm 275mm 275mm 275mm 275mm 275mm 275mm 275mm total total total total total total total total total total total total ENGLER VISCOSITY ASTM 23C 24C 25C IP CAT NO 1092 1093 1094 Viscosity Engler Viscosity Engler Viscosity Engler 18 to 28OC 39 to 54OC 95 to 105OC 0.2 0.2 0.2 212mm 237mm 212mm 90mm 90mm 90mm STABILITY TEST OF SOLUBLE NITROCELLULOSE ASTM 26C IP CAT NO 1120 APPLICATION Stab Test Sot Nit Cell 130 to 140OC 0.1 463mm total TURPENTINE DISTILLATION ASTM 27C IP CAT NO 1122 APPLICATION Turpentine Dist. 147 to 182OC 0.5 301mm 76mm KINEMATIC VISCOSITY ASTM 28C 28F 29C 29F 30F IP 31C 31F 34C 34F 32F CAT NO 1097G 1096G 1097I 1096I 1096M Kinematic Viscosity Kinematic Viscosity Kinematic viscosity Kinematic Viscosity Kinematic viscosity APPLICATION 36.6 to 39.4OC 97.5 to 102.5OF 52.6 to 55.4OC 127.5 to 132.5OF 207.5 to 212.5OF TEMP RANGE 0.05 0.1 0.05 0.1 0.1 DIV LENGTH IMMERSION CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION 305mm 305mm 305mm 305mm 305mm total total total total total REID VAPOR ASTM 31F IP 1003 Reid Vapor -30 to 120OF 1 305mm total ANILINE POINT ASTM 33C 33F 34C 34F 35C 35F IP 20F 21F 59F 1126 1127 1128 1129 1130 1131 Aniline Aniline Aniline Aniline Aniline Aniline Point Point Point Point Point Point -38 to 42OC -36.5 to 107.5OF 25 to 105OC 77 to 221OF 90 to 170OC 194 to 338OF 0.2 0.5 0.2 0.5 0.2 0.5 420mm 420mm 420mm 420mm 420mm 420mm 50mm 50mm 50mm 50mm 50mm 50mm 1056 TITER TEST ASTM 36C IP 1272 Titer Test -2 to 68ºC 0.2 405mm 45mm Page 13 SOLVENTS DISTILLATION ASTM 37C 38C 39C 40C 41C 42C IP 77C 78C 79C 80C 81C 82C CAT NO APPLICATION 1132 1134 1136 1138 1140 1142 Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation Solvents Distillation TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE -2 to 52OC 24 to 78OC 48 to 102OC 72 to 126OC 98 to 152OC 95 to 255OC 0.2 0.2 0.2 0.2 0.2 0.5 395mm 395mm 395mm 395mm 395mm 395mm 100mm l00mm 100mm l00mm 100mm 100mm KINEMATIC VISCOSITY ASTM 43C 43F 44C 44F 45C 45F 46C 46F 47C 47F 48C 48F IP 65C 65F 29C 29F 30C 30F 66C 66F 35C 35F 90C 90F CAT NO APPLICATION 1097B 1096B 1096Q 1096E 1096R 1096F 1096S 1096H 1096T 1096K 1097L 1096L Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic viscosity Kinematic viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity -51.6 to -34OC -61 to -29OF 18.5 to 21.5OC 66.5 to 71.5OF 23.6 to 26.4OC 74.5 to 79.5OF 48.6 to 51.4OC 19.5 to 124.5OF 58.6 to 61.4OC 137.5 to 142.5OF 80.6 to 83.4OC 177.5 to 182.5OF DIV 0.1 0.2 0.05 0.1 0.05 0.1 0.05 0.1 0.05 0.1 0.05 0.1 LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE 19 to 35OC 66 to 95OF 0.02 0.05 DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION 417mm 417mm 305mm 305mm 305mm 305mm 305mm 305mm 305mm 305mm 305mm 305mm total total total total total total total total total total total total STORMER VISCOSITY ASTM 49C IP CAT NO 1095 Stormer Viscosity 20 to 70OC 0.2 305mm 65mm GAS CALORIMETER ASTM 50F 51F IP CAT NO 1144 1146 Gas Calorimeter inlet Gas Calorimeter inlet 54 to 101OF 69 to 116OF 0.1 0.1 468mm 468mm total total BUTADINE BOILING POINT ASTM 52C IP CAT NO 1148 APPLICATION Butadine Boiling Pt. -10 to 5OC 0.1 162mm total BENZENE FREEZING POINT ASTM 53C IP CAT NO 1148C Benzene Freezing Pt. -0.6 to 10.4OC 0.1 189mm total CONGEALING POINT ASTM 54C 54F IP 18C 18F CAT NO 1048 1047 Congealing Point Congealing Point 20 to 100.6OC 68 to 213OF 0.2 0.5 310mm 310mm total total BOMB CALORIMETER ASTM 56C 56F IP CAT NO 1147 1147A Bomb Calorimeter Bomb Calorimeter 585mm 585mm total total TAG CLOSED TESTER ASTM 57C 57F IP CAT NO 1034 1032 Flash Tag Closed Low Flash Tag Closed Low -20 to 50OC -4 to 122OF 0.5 1 290mm 290mm 1272 57mm 57mm 1096E ASTM THERMOMETERS TANK GAUGING – REFILL ASTM 58C 58F 59C 59F 60C 60F IP CAT NO 1248 1252 1253 1256 1257 1260 APPLICATION Tank, Refill, Low Tank, Refill, Low Tank, Refill, Medium Tank, Refill, Medium Tank, Refill, High Tank, Refill, High TEMP RANGE -34 to 49OC -30 to 120OF -18 to 82OC 0 to 180OF 77 to 260OC 170 to 500OF DIV 0.5 1 0.5 1 1 2 LENGTH 300mm 300mm 300mm 300mm 300mm 300mm IMMERSION total total total total total total ANY OF THE ABOVE MAY BE FURNISHED WITH RED READING LENS GLASS AT ADDITIONAL COST. ADD SUFFIX“RRL” TO CATALOG NUMBER. PETROLATUM MELT POINT ASTM 61C 61F IP 16C CAT NO 1053 1052 APPLICATION Petrolatum Melt Pt. Petrolatum Melt Pt. TEMP RANGE 32 to 127OC 90 to 260OF DIV 0.2 0.5 LENGTH 380mm 380mm IMMERSION 79mm 79mm ASTM PRECISION SERIES • ETCHED STEM MERCURY-IN-GLASS THERMOMETERS MANUFACTURED IN STRICT ACCORDANCE WITH ASTM AND NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (FORMERLY NBS) SPECIFICATIONS. • EXTENSIVELY AGED AND ANNEALED FOR MINIMAL SCALE ERROR AND EXTENDED LIFE. • AUXILIARY ICE POINT REFERENCE SCALE FOR VERIFICATION OF MAIN SCALE CORRECTIONS. ASTM 62C 63C 64C 65C 66C 67C 68C 69C 70C 1296 COMPLETE ASTM 62F 63F 64F 65F 66F 67F 68F 69F 70F 1298 IP 2C 61C 12C 43C 46C 72C 73C 74C CAT NO 1300 1302 1304 1306 1308 1310 1312 1314 1316 SET OF IP 2F 12F 43F 46F 72F 73F 74F COMPLETE CELSIUS APPLICATION Precision Precision Precision Precision Precision Precision Precision Precision Precision RANGES CAT NO 1320 1322 1324 1326 1328 1330 1332 1334 1336 SET OF FAHRENHEIT ASTM 62C TEMP RANGE -38 to 2OC -8 to 32OC 25 to 55OC 50 to 80OC 75 to 105OC 95 to 155OC 145 to 205OC 195 to 305OC 295 to 405OC THROUGH APPLICATION Precision Precision Precision Precision Precision Precision Precision Precision Precision RANGES ASTM 62F 70C LENGTH 379mm 379mm 379mm 379mm 379mm 379mm 379mm 379mm 379mm IMMERSION total total total total total total total total total FURNISHED IN A VELVET-LINED PROTECTIVE CASE. TEMP RANGE -36 to 35OF 18 to 89OF 77 to 131OF 122 to 176OF 167 to 221OF 203 to 311OF 293 to 401OF 383 to 581OF 563 to 761OF THROUGH DIV 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.5 0.5 70F DIV 0.2 0.2 0.2 0.2 0.2 0.5 0.5 1.0 1.0 LENGTH 379mm 379mm 379mm 379mm 379mm 379mm 379mm 379mm 379mm IMMERSION total total total total total total total total total 1256 FURNISHED IN A VELVET-LINED PROTECTIVE CASE. 1308 Page 15 OIL IN WAX ASTM 71C 71F CAT NO 1293A 1293 APPLICATION Oil in Wax 0il in Wax TEMP RANGE -37 to 21OC -35 to 70OF DIV LENGTH IMMERSION 0.5 1 355mm 355mm 76mm 76mm KINEMATIC VISCOSITY ASTM 72C 72F 73C 73F 74C 74F CAT NO 1097A 1096A 1096U 1096C 1096D 10960 APPLICATION -19.4 to -16.6OC -2.5 to +2.5OF -41.4 to -38.6OC -42.5 to -37.5OF -55.4 to -52.6OC -67.5 to -62.5OF 0.05 0.1 0.05 0.1 0.05 0.1 DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic viscosity TEMP RANGE 305mm 305mm 305mm 305mm 305mm 305mm total total total total total total COOLANT FREEZING POINT ASTM 75F 76F CAT NO 1200 1202 Coolant Freezing Pt. Coolant Freezing Pt. -35 to 35OF -65 to +5OF 0.5 0.5 408mm 408mm 100mm 100mm SAYBOLT VISCOSITY ASTM 77F 78F 79F 80F 81F CAT NO 1077 1079 1080 1082 1084 Viscosity Viscosity Viscosity Viscosity Viscosity Saybolt Saybolt Saybolt Saybolt Saybolt 245 295 345 395 445 to to to to to 265OF 315OF 365OF 415OF 465OF 0.5 0.5 0.5 0.5 0.5 275mm 275mm 275mm 275mm 275mm total total total total total FUEL RATING ASTM 82F 82C 83F 83C 84F 84C 85F 85C 86F 86C 87F 87C CAT NO 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 Fuel Rating, Engine Fuel Rating, Engine Fuel Rating, Air Fuel Rating, Air Fuel Rating, Orifice Fuel Rating, Orifice Fuel Rating, Surge Fuel Rating, Surge Fuel Rating, Mix Fuel Rating, mix Fuel Rating, Coolant Fuel Rating, Coolant 0 to 220OF -15 to 105OC 60 to 160OF 15 to 70OC 75 to 175OF 25 to 80OC 100 to 300OF 40 to 1S0OC 200 to 350OF 95 to 174OC 300 to 400OF 150 to 205OC 2 1 1 1 1 1 2 1 2 1 1 1 165mm 165mm 174mm 174mm 387mm 387mm 314mm 314mm 170mm 170m 175mm 175mm 30mm 30mm 40mm 40mm 249m 249m 181mm 181mm 35mm 35mm 40mm 40mm VEGETABLE OIL FLASH ASTM 88C 88F CAT NO 1216 1218 APPLICATION Vegetable Oil Flash Vegetable Oil Flash 10 to 200OC 50 to 392OF 1 2 287mm 287mm 57mm 57mm SOLIDIFICATION POINT ASTM 89C 90C 91C 92C 93C 94C 95C 96C CAT NO 1220 1222 1224 1226 1228 1230 1232 1234 APPLICATION Solidification Solidification Solidification Solidification Solidification Solidification Solidification Solidification Point Point Point Point Point Point Point Point -20 to +10OC 0 to 30OC 20 to 50OC 40 to 70OC 60 to 90OC 80 to 110OC 100 to 130OC 120 to 150OC 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 370mm 370mm 370mm 370mm 370mm 370mm 370mm 370mm 76mm 76mm 76mm 76mm 76mm 76mm 76mm 76mm TANK GAUGING – REFILL ASTM 97C 97F 98C 98F CAT NO 1244 1262 1246 1264 APPLICATION TEMP RANGE DIV LENGTH Tank, Refill -18 to 49OC 0.5 300mm Tank, Refill 0 to 120OF 1 300mm Tank, Refill 16 to 82OC 0.5 300mm Tank, Refill 60 to 180OF 1 300mm (FOR COMPLETE UNITS AND CASES, SEE GAUGING SECTION, PAGE #) IMMERSION total total total total 1220 1082 1214 ASTM THERMOMETERS WEATHERING TEST ASTM 99F 99C CAT NO APPLICATION 1278 1279 TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION Weathering Test Weathering Test -58 to 41OF -50 to +5OC 0.5 0.2 305mm 305mm 35mm 35mm SOLIDIFICATION POINT ASTM 100C 101C CAT NO APPLICATION 1236 1238 Solidification Point Solidification Point 145 to 205OC 195 to 305OC 0.2 0.5 370mm 370mm 76mm 76mm SOLVENTS DISTILLATION ASTM 102C 103C 104C 105C 106C 107C CAT NO 1266 1268 1270 1273 1274 1276 Solvents Solvents Solvents Solvents Solvents Solvents Distillation Distillation Distillation Distillation Distillation Distillation 123 148 173 198 223 248 to to to to to to 177OC 202OC 227OC 252OC 277OC 302OC 0.2 0.2 0.2 0.2 0.2 0.2 395mm 395mm 395mm 395mm 395mm 395mm l00mm 100mm 100mm 100mm 100mm l00mm SAYBOLT VISCOSITY ASTM 108F 109F CAT NO 1091A 1091B Viscosity Saybolt Viscosity Saybolt 270 to 290OF 320 to 340OF 0.5 0.5 275mm 275mm total total KINEMATIC VISCOSITY ASTM 110C 110F CAT NO APPLICATION 1096V 1096N 133.6 to 136.4OC 272.5 to 277.5OF 0.05 0.1 DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION APPLICATION TEMP RANGE DIV LENGTH IMMERSION APPLICATION Bomb Calorimeter Bomb Calorimeter TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION DIV LENGTH IMMERSION Kinematic viscosity Kinematic Viscosity TEMP RANGE 305mm 305mm total total TAR ACID DISTILLATION ASTM 111C CAT NO 1284 APPLICATION Tar Acid Distillation 170 to 250OC 0.2 395mm 100mm SOLIDIFICATION POINT OF BENZENE ASTM 112C CAT NO 1286 APPLICATION Solidification Benzene TEMP RANGE 4 to 6OC 0.02 220mm total BITUMINOUS MATERIALS SOFTENING POINT ASTM 113C CAT NO APPLICATION 1289 Bit. Mat. Sftn. Pt. -1 to 175OC 0.5 4O6mm total AVIATION FUELS FREEZING POINT ASTM 114C 114F CAT NO 1290 1291 Aviation Fuel Frz. Pt. Aviation Fuel Frz. Pt. -80 to 20OC -112 to 70OF 0.5 1.0 300mm 300mm total total BOMB CALORIMETER ASTM 116C 117C CAT NO 1147B 1147C 18.9 to 25.1OC 23.9 to 30.1OC 0.01 0.01 609mm 609mm total total KINEMATIC VISCOSITY ASTM 118F 118C CAT NO 1096P 1096W APPLICATION Kinematic viscosity Kinematic viscosity 83.5 to 88.5OF 28.6 to 31.4OC 0.1 0.05 305mm 305mm COOLANT FREEZING POINT ASTM 119C 119F CAT NO 1096X 1097X APPLICATION Coolant Frz. Pt. Coolant Frz. Pt. TEMP RANGE -35.5 to -30OC -37 to -22OF 0.05 0.1 305mm 3O5mm 1096N total total 1268 total total Page 17 KINEMATIC VISCOSITY ASTM 120C 121C CAT NO 1096Y 1096Z APPLICATION Kinematic Viscosity Kinematic viscosity 38.5 to 41.5OC 98.5 to 101.5OC TEMP RANGE 0.05 0.05 DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION 305mm 305mm total total BROOKFIELD VISCOSITY ASTM 122C 123C 124C 125C CAT NO 1098A 1098B 1098C 10980 APPLICATION Brookfield viscosity Brookfield Viscosity Brookfield Viscosity Brookfield Viscosity -45 to -35OC -35 to -25OC -25 to -15OC -15 to -5OC 0.1 0.1 0.1 0.1 300mm 300mm 300mm 300mm total total total total KINEMATIC VISCOSITY ASTM 126C 126F 127C 128C 128F 129C 129F 132C CAT NO 1098E 1098F 1098G 1098H 10981 1098J 1098K 1098L APPLICATION Kinematic Viscosity Kinematic Viscosity Kinematic viscosity Kinematic Viscosity Kinematic Viscosity Kinematic Viscosity Kinematic viscosity Kinematic Viscosity -27.4 to -24.6OC -17.5 to -12.5OF -21.4 to -18.6OC -1.4 to +1.4OC 29.5 to 34.5OF 91.6 to 94.4OC 197.5 to 202.5OF 148.6 to 151.4OC 0.05 0.1 0.05 0.05 0.1 0.05 0.1 0.05 305mm 305mm 305mm 305mm 305mm 305mm 305mm 305mm total total total total total total total total TANK GAUGING – REFILL ASTM 130C 130F CAT NO 1271 1261 APPLICATION Tank Gauging, Refill Tank Gauging, Refill -7 to 110OC 20 to 220OF 0.5 1 305mm 305mm total total PRECISION-PARTIAL IMMERSION ASTM 133C CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION CAT NO APPLICATION TEMP RANGE DIV LENGTH IMMERSION 1099 Precision-Partial Immersion -38 to +2OC 0.1 379mm 76mm SLUDGE ASTM 134C 1100 Sludge 144 to 156OC 0.2 270mm 100mm 1271 Page <#> ASTM THERMOMETERS LOW TOXIC NON-MERCURY DENSITY - WIDE RANGE (GRAVITY) ASTM S12C-03 S12F-03 CAT NO 1042-S 1040-S APPLICATION TEMP RANGE APPLICATION TEMP RANGE 19 to 35OC 66 to 95OF 0.02 0.05 APPLICATION Density Wide Range Density Wide Range DIV LENGTH IMMERSION DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION TEMP RANGE DIV LENGTH IMMERSION DIV LENGTH IMMERSION -20 to 102OC -5 to 215OF 0.2 0.5 435mm 435mm total total BOMB CALORIMETER ASTM S56C-03 S56F-03 CAT NO 1147-S 1147A-S Bomb Calorimeter Bomb Calorimeter 610mm 610mm total total TANK GAUGING ASTM S59C-03 S59F-03 CAT NO 1253-S 1256-S Tank Tank -18 to 82OC 0 to 180OF 0.5 1 300mm 300mm total total PRECISION-TOTAL IMMERSION ASTM S62C-03 S62F-03 S63C-03 S63F-03 S64C-03 S64F-03 S65C-03 S65F-03 S66C-03 S66F-03 S67C-03 S67F-03 CAT NO 1300-S 1320-S 1302-S 1322-S 1304-S 1324-S 1306-S 1326-S 1308-S 1328-S 1310-S 1330-S APPLICATION Precision Precision Precision Precision Precision Precision Precision Precision Precision Precision Precision Precision -38 to 2OC -36 to 35OF -8 to 32OC 18 to 89OF 25 to 55OC 77 to 131OF 50 to 80OC 122 to 176OF 75 to 105OC 167 to 221OF 95 to 155OC 203 to 311OF 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.2 0.5 401mm 401mm 401mm 401mm 401mm 401mm 401mm 401mm 401mm 401mm 401mm 401mm total total total total total total total total total total total total SOLIDIFICATION POINT ASTM S91C-03 CAT NO 1224-S APPLICATION Solidification Point 20 to 50OC 0.1 390mm 76mm KINEMATIC VISCOSITY ASTM S120C-03 CAT NO 1096Y-S APPLICATION Kinematic Viscosity TEMP RANGE 38.6 to 41.1OC 0.05 300mm total 1042-S Page 19 ASTM CERTIFIED MASTER THERMOMETERS Page 21 PARTIAL IMMERSION ASTM 1C 1F 2C 2F 3C 3F IP CAT NO CERTIFICATION TEST POINTS 62C 62F 73C 1102-C 1104-C 1106-C 1108-C 1110-C Certified Certified Certified Certified Certified @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified test test test test test points points points points points of of of of of -20, 0, 50, 100, 150C 0, 32, 122, 212, 302F 0, 75, 150, 225, 300C 32, 150, 300, 450, 580F 0, 100, 200, 300, 370C 73F 1112-C Certified @ ASTM specified test points of 32, 200, 370, 540, 700F ACID HEAT ASTM 4C 4F IP CAT NO 1002-C 1000-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 50, 100C Certified @ ASTM specified test points of 32, 122, 215F CLOUD AND POUR - LOW AND HIGH ASTM 5C 5F 6C 1C 1F 2C IP CAT NO 1006-C 1004-C 1010-C Certified @ ASTM specified test points of -30, 0, 50C Certified @ ASTM specified test points of -30, 32, 120C Certified @ ASTM specified test points of -70, 35, 0, 20C CERTIFICATION TEST POINTS 6F 2F 1008-C Certified @ ASTM specified test points of -94, -30, 32, 70F DISTILLATION - LOW AND HIGH ASTM 7C 7F 8C IP 5C CAT NO 6C 8F CERTIFICATION TEST POINTS 1014-C 1012-C 1018-C Certified @ ASTM specified test points of 0, 50, 100, 150, 200, 250, 300C Certified @ ASTM specified test points of 32, 100, 200, 300, 400, 500, 570F Certified @ ASTM specified test points of 0, 100, 200, 300, 370C 1016-C Certified @ ASTM specified test points of 32, 200, 370, 540, 700F PENSKY-MARTENS - LOW AND HIGH ASTM 9C 9F 10C 15C 15F 16C IP CAT NO 1022-C 1020-C 1026-C Certified @ ASTM specified test points of 0, 35, 70, 150C Certified @ ASTM specified test points of 32, 100, 160, 220F Certified @ ASTM specified test points of 100, 200, 300, 370C CERTIFICATION TEST POINTS 10F 16F 1024-C Certified @ ASTM specified test points of 212, 390, 570, 700F OPEN FLASH ASTM 11C 11F IP 28C 28F CAT NO 1038-C 1036-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 100, 200, 300, 370C Certified @ ASTM specified test points of 32, 200, 370, 540, 700F DENSITY - WIDE RANGE (GRAVITY) ASTM 12C 12F IP 64C 64F CAT NO 1042-C 1040-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -20, -10, 0, 10, 20, 30, 40, 50C Certified @ ASTM specified test points of -5, 15, 32, 60, 85F LOSS ON HEAT ASTM 13C IP 47C CAT NO 1048A-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 155, 163, 170C PARAFFIN WAX MELTING POINT ASTM 14C 14F IP 17C 17F CAT NO 1051-C 1050-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 40, 50, 60, 70, 80C Certified @ ASTM specified test points of 100, 120, 140, 160, 180F 1042-C SOFTENING POINT ASTM 15C 15F 16C 16F IP 60C 61C CAT NO 1056-C 1054-C 1060-C 1058-C 1010-C CERTIFICATION TEST POINTS Certified Certified Certified Certified @ @ @ @ ASTM ASTM ASTM ASTM specified specified specified specified test test test test points points points points of of of of 0, 20, 40, 60, 80C 32, 70, 100, 140, 180F 30, 60, 90, 120, 150, 180, 200C 90, 140, 190, 240, 290, 340, 390F ASTM CERTIFIED MASTER SAYBOLT VISCOSITY ASTM 17C 17F 18C 18F 19C 19F 20C 20F 21C 21F 22C 22F IP 23C 23F 24C 24F CAT NO 1085-C 1066-C 1086-C 1067-C 1087-C 1068-C 1088-C 1069-C 1089-C 1075-C 1090-C 1076-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified specified specified specified specified specified specified test test test test test test test test test test test test points points points points points points points points points points points points of of of of of of of of of of of of 21, 25C 70, 77F 38, 41C 100, 107F 50, 54C 122, 130F 60, 64C 140, 147F 82, 86C 180, 187F 99, 102C 210, 212C ENGLER VISCOSITY ASTM 23C 24C 25C IP CAT NO 1092-C 1093-C 1094-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 20, 25C Certified @ ASTM specified test points of 40, 50C Certified @ ASTM specified test points of 95, 100C STABILITY TEST OF SOLUBLE NITROCELLULOSE ASTM 26C IP CAT NO 1120-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 130, 135, 140C TURPENTINE DISTILLATION ASTM 27C IP CAT NO 1122-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 155, 165, 175C KINEMATIC VISCOSITY ASTM 28C 28F 29C 29F 30F IP 31C 31F 34C 34F 32F CAT NO CERTIFICATION TEST POINTS 1097G-C 1096G-C 1097I-C 1096I-C 1096M-C Certified Certified Certified Certified Certified CAT NO CERTIFICATION TEST POINTS @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified test test test test test points points points points points of of of of of 0, 37.8, 39C 32, 100, 102F 0, 54.4, 55C 32, 130, 132F 32, 210, 212F REID VAPOR ASTM 31F IP 1003-C Certified @ ASTM specified test points of -20, 32, 100F ANILINE POINT ASTM 33C 33F 34C 34F 35C 35F IP 20F 21F 59F CAT NO 1126-C 1127-C 1128-C 1129-C 1130-C 1131-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified test test test test test test points points points points points points of of of of of of -35, -20, 0, 20, 40C -31, -4, 32, 68, 104F 25, 45, 65, 85, 100C 77, 113, 149, 185, 212F 100, 120, 140, 160, 170C 212, 250, 285, 320, 338F TITER TEST ASTM 36C IP CAT NO 1272-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 15, 30, 45, 65C SOLVENTS DISTILLATION ASTM 37C 38C 39C 40C 41C 42C IP 77C 78C 79C 80C 81C 82C CAT NO 1132-C 1134-C 1136-C 1138-C 1140-C 1142-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified test test test test test test points points points points points points of of of of of of 15, 30, 50C 25, 40, 55, 75C 50, 65, 80, 100C 75, 90, 105, 125C 100, 115, 130, 150C 100, 150, 200, 250C 1096E-C 1056-C 1067-C Page 23 KINEMATIC VISCOSITY ASTM 43C 43F 44C 44F 45C 45F 46C 46F 47C 47F 48C 48F IP 65C 65F 29C 29F 30C 30F 66C 66F 35C 35F 90C 90F CAT NO 1097B-C 1096B-C 1096Q-C 1096E-C 1096R-C 1096F-C 1096S-C 1096H-C 1096T-C 1096K-C 1097L-C 1096L-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified specified specified specified specified specified specified test test test test test test test test test test test test points points points points points points points points points points points points of of of of of of of of of of of of -50, -45, -40, -35, 0C -60, -50, -40, -30, +32F 0, 20, 21C 32, 68, 70F 0, 25, 26C 32, 77, 79F 0, 50, 51C 32, 122, 124F 0, 60, 61C 32, 140, 142F 0, 82.2, 83C 32, 180, 182F STORMER VISCOSITY ASTM 49C IP CAT NO 1095-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 20, 35, 50, 70C GAS CALORIMETER ASTM 50F 51F IP CAT NO 1144-C 1146-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 55, 60, 70, 75, 80, 85, 90, 85, 100F Certified @ ASTM specified test points of 70, 75, 80, 85, 90, 95, 100, 105, 110, 115F BUTADINE BOILING POINT ASTM 52C IP CAT NO 1148-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -10, 0, 5C BENZENE FREEZING POINT ASTM 53C IP CAT NO 1148C-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 5, 10C CONGEALING POINT ASTM 54C 54F IP O 18 OC 18 F CAT NO 1048-C 1047-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 20, 50, 75, 100C Certified @ ASTM specified test points of 70, 120, 170, 210F BOMB CALORIMETER ASTM 56C 56F IP CAT NO 1147-C 1147A-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 19, 21, 23, 25, 27, 29, 31, 33, 35C Certified @ ASTM specified test points of 66, 70, 74, 78, 82, 88, 92, 95F TAG CLOSED TESTER ASTM 57C 57F IP CAT NO 1034-C 1032-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -20, 25, 50C Certified @ ASTM specified test points of -3, 32, 77, 122F 1272-C 1082-C ASTM CERTIFIED MASTER TANK GAUGING – REFILL ASTM 58C 58F 59 59F 60C 60F IP CAT NO CERTIFICATION TEST POINTS 1248-C Certified @ ASTM specified test points of -30, 0, 25, 45C 1252-C Certified @ ASTM specified test points of -20, 32, 80, 120F 1253-C Certified @ ASTM specified test points of 0, 25, 55, 80C 1256-C Certified @ ASTM specified test points of 32, 80, 180, 180F 1257-C Certified @ ASTM specified test points of 100, 175, 255C 1260-C Certified @ ASTM specified test points of 212, 350, 490F (FOR COMPLETE UNITS AND CASES, SEE GAUGING SECTION, PAGE #) ANY OF THE ABOVE MAY BE FURNISHED WITH RED READING LENS GLASS AT ADDITIONAL COST. ADD SUFFIX“RRL” TO CATALOG NUMBER. PETROLATUM MELT POINT ASTM 61C 61F IP 16C CAT NO 1053-C 1052-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 40, 60, 80, 100, 120C Certified @ ASTM specified test points of 100, 150, 200, 250F ASTM PRECISION SERIES PRIMARY REFERENCE STANDARDS CERTIFIED TRACEABLE TO NIST 1256-C • THERMOMETERS AS ON FACING PAGE, CERTIFIED NIST (FORMERLY NBA) TRACEABLE AT THE ICE POINT AND FOUR POINTSON THE MAIN SCALE, AS SPECIFIED BY ASTM E-1. WITH CERTIFICATE OF CALIBRATION AS SHOWN. • IDEAL FOR USE AS PRIMARY LABORATORY REFERENCE STANDARDS. ASTM 62C 63C 64C 65C 66C 67C 68C 69C 70C IP 2C 61C 12C 43C 46C 72C 73C 74C CAT NO 1300C 1302C 1304C 1306C 1308C 1310C 1312C 1314C 1316C TEMP RANGE -38 to 2OC -8 to 32OC 25 to 55OC 50 to 80OC 75 to 105OC 95 to 155OC 145 to 205OC 195 to 305OC 295 to 405OC 62F 63F 64F 65F 66F 67F 68F 69F 70F 2F 1320C 1322C 1324C 1326C 1328C 1330C 1332C 1334C 1336C -36 to 35OF 18 to 89OF 77 to 131OF 122 to 176OF 167 to 221OF 203 to 311OF 293 to 401OF 383 to 581OF 563 to 761OF 12F 43F 46F 72F 73F 74F CORRECTIONS GIVEN AT -37 -30 -20 -7 0 10 0 25 35 0 50 60 0 75 85 0 100 110 0 150 170 0 200 235 0 300 335 -35 20 32 32 32 32 32 32 32 -15 32 80 125 168 205 300 400 570 0 50 95 145 185 240 340 460 640 EACH TEMPERATURE -10 20 45 70 95 130 190 270 370 15 70 115 160 200 275 370 520 700 0C 30C 55C 80C 105C 150C 205C 305C 400C 32 88 130 175 220 310 400 580 760 AVAILABLE INDIVIDUALLY OR IN SETS. COMPLETE SET OF FAHRENHEIT THERMOMETERS, ASTM NUMBERS 62F THROUGH 70F, EACH FURNISHED WITH NIST TRACEABLE CERTIFICATE OF CALIBRATION IN A VELVET LINED PROTECTIVE CASE. CATALOG NO. 1298-C COMPLETE SET OF CELSIUS THERMOMETERS, ASTM NUMBERS 62C THROUGH 70C, EACH FURNISHED WITH NIST TRACEABLE CERTIFICATE OF CALIBRATION IN A VELVET LINED PROTECTIVE CASE. CATALOG NO. 1296-C Page 25 OIL IN WAX ASTM 71C 71F IP CAT NO 1293A-C 1293-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -35, -18, 0, 20C Certified @ ASTM specified test points of -30, 0, 32, 70F KINEMATIC VISCOSITY ASTM 72C 72F 73C 73F 74C 74F IP CAT NO 1097A-C 1096A-C 1096U-C 1096C-C 109Th-C 10960-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified test test test test test test points points points points points points of of of of of of -19, -17.8, 0C -2, 0, 32F -41, 0C -42, -41, 32F -55, -55.9, 0C -67, -65, 32F COOLANT FREEZING POINT ASTM 75F 76F IP CAT NO 1200-C 1202-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -35, 0, 32F Certified @ ASTM specified test points of -65, -30, 32F SAYBOLT VISCOSITY ASTM 77F 78F 79F 80F 81F IP CAT NO 1077-C 1079-C 1080-C 1082-C 1084-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified test test test test test points points points points points 260F 310F 360F 410F 460F of of of of of 250, 300, 350, 400, 450, of of of of of of of of of of of of 32, 100, 200F 0, 50, 100C 85, 135F 25, 70C 100, 150F 30, 80C 150, 250F 50, 150C 225, 325F 100, 175C 300, 400F 160, 200C FUEL RATING ASTM 82F 82C 83F 83C 84F 84C 85F 85C 86F 86C 87F 87C IP CAT NO 1204-C 1205-C 1206-C 1207-C 1208-C 1209-C 1210-C 1211-C 1212-C 1213-C 1214-C 1215-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified specified specified specified specified specified specified test test test test test test test test test test test test points points points points points points points points points points points points VEGETABLE OIL FLASH ASTM 88C 88F IP CAT NO 1216-C 1218-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 40, 100, 150, 200C Certified @ ASTM specified test points of 110, 212, 300, 392F 1214-C SOLIDIFICATION POINT ASTM 89C 90C 91C 92C 93C 94C 95C 96C IP CAT NO 1220-C 1222-C 1224-C 1226-C 1228-C 1230-C 1232-C 1234-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified specified specified test test test test test test test test points points points points points points points points of of of of of of of of -20, -10, 0, 10C 0, 10, 20, 30C 20, 30, 40, 50C 40, 50, 60, 70C 60, 70, 80, 90C 80, 90, 100, 110C 100, 110, 120, 130C 120, 130, 140, 150C of of of of -50, 0, 20, 45C 0, 32, 70, 110F 20, 40, 60, 80C 60, 100, 140, 180F TANK GAUGING – REFILL ASTM 97C 97F 98C 98F IP CAT NO 1244-C 1262-C 1246-C 1264-C CERTIFICATION TEST POINTS Certified Certified Certified Certified @ @ @ @ ASTM ASTM ASTM ASTM specified specified specified specified test test test test points points points points 1220-C ASTM CERTIFIED MASTER WEATHERING TEST ASTM 99F 99C IP CAT NO 1278-C 1279-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -50, -25, 0, 32F Certified @ ASTM specified test points of -46, -32, -18, 0C SOLVENTS DISTILLATION ASTM 102C 103C 104C 105C 106C 107C IP CAT NO 1266-C 1268-C 1270-C 1273-C 1274-C 1276-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified test test test test test test points points points points points points of of of of of of 125, 150, 175, 200, 225, 250, 140, 165, 190, 215, 240, 265, 155, 180, 205, 230, 255, 280, 175C 200C 225C 250C 275C 300C SAYBOLT VISCOSITY ASTM 108F 109F IP CAT NO 1091A-C 1091B-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 275, 285F Certified @ ASTM specified test points of 325, 335F KINEMATIC VISCOSITY ASTM 110C 110F IP CAT NO 1096V-C 1096N-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 135, 136C Certified @ ASTM specified test points of 32, 375, 377F TAR ACID DISTILLATION ASTM 111C IP CAT NO 1284-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 170, 200, 250C SOLIDIFICATION POINT OF BENZENE ASTM 112C IP CAT NO 1286-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 4, 5, 6C BITUMINOUS MATERIALS SOFTENING POINT ASTM 113C IP CAT NO 1289-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 50, 100, 150, 175C AVIATION FUELS FREEZING POINT ASTM 114C 114F IP CAT NO 1290-C 1291-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -75, -60, -40, 0C Certified @ ASTM specified test points of -103, -76, -40, 32F BOMB CALORIMETER ASTM 116C 117C IP CAT NO 1147B-C 1147C-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 19, 20, 21, 22, 23, 24, 25C Certified @ ASTM specified test points of 24, 25, 26, 27, 28, 29, 30C KINEMATIC VISCOSITY ASTM 118F 118C IP CAT NO 1096P--C 1096W-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 32, 86, 88F Certified @ ASTM specified test points of 0, 30, 31C 1290-C COOLANT FREEZING POINT ASTM 119C 119F IP CAT NO 1096X-C 1097X-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -38, -30, 0C Certified @ ASTM specified test points of -36, -22, +32F 1268-C KINEMATIC VISCOSITY ASTM 120C 121C IP CAT NO 1096Y-C 1096Z-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 40, 41C Certified @ ASTM specified test points of 0, 100, 101C Page 27 BROOKFIELD VISCOSITY ASTM 122C 123C 124C 125C IP CAT NO 1098A-C 1098B-C 1098C-C 10980-C CERTIFICATION TEST POINTS Certified Certified Certified Certified @ @ @ @ ASTM ASTM ASTM ASTM specified specified specified specified test test test test points points points points -40, -30, -20, -10, -35C -25C -15C -5C of of of of -45, -35, -25, -15, of of of of of of of of -27, -26.1, 0C -17, -15, +32F -21, -20, 0C 0, 1C 32, 34F 0, 93.3, 94C 32, 200, 202F 0, 150, 151C KINEMATIC VISCOSITY ASTM 126C 126F 127C 128C 128F 129C 129F 132C IP CAT NO 1098E-C 1098F-C 1098G-C 1098H-C 10981-C 1098J-C 1098K-C 1098L -C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified specified specified test test test test test test test test points points points points points points points points TANK GAUGING – REFILL ASTM 130C 130F IP CAT NO 1271-C 1261-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 35, 70, 105C Certified @ ASTM specified test points of 32, 100, 160, 220F PRECISION-PARTIAL IMMERSION ASTM 133C IP CAT NO IP CAT NO 1099-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -36, -30, -24, -18, -12, -6, 0C SLUDGE ASTM 134C 1100-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 145, 150, 155C 1271-C ASTM CERTIFIED MASTER LOW TOXIC NON-MERCURY DENSITY - WIDE RANGE (GRAVITY) ASTM S12C-03 S12F-03 IP CAT NO 1042-S-C 1040-S-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of -20, -10, 0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100C Certified @ ASTM specified test points of -5, 15, 32, 60, 85, 110, 135, 160, 185, 210F BOMB CALORIMETER ASTM S56C-03 S56F-03 IP CAT NO 1147-S-C 1147A-S-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 19, 21, 23, 25, 27, 29, 31, 33, 35C Certified @ ASTM specified test points of 65, 69, 73, 77, 81, 85, 89, 93, 95F TANK GAUGING ASTM S59C-03 S59F-03 IP CAT NO 1253-S-C 1256-S-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 25, 55, 80C Certified @ ASTM specified test points of 32, 80, 130, 180F PRECISION-TOTAL IMMERSION ASTM S62C-03 S62F-03 S63C-03 S63F-03 S64C-03 S64F-03 S65C-03 S65F-03 S66C-03 S66F-03 S67C-03 S67F-03 IP CAT NO 1300-S-C 1320-S-C 1302-S-C 1322-S-C 1304-S-C 1324-S-C 1306-S-C 1326-S-C 1308-S-C 1328-S-C 1310-S-C 1330-S-C CERTIFICATION TEST POINTS Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified Certified @ @ @ @ @ @ @ @ @ @ @ @ ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM specified specified specified specified specified specified specified specified specified specified specified specified test test test test test test test test test test test test points points points points points points points points points points points points of of of of of of of of of of of of -37, -30, -20, -10, 0C -35, -15, 0, 15, 32F -7, 0, 10, 20, 30C 20, 32, 50, 70, 88F 0, 25, 35, 45, 55C 32, 80, 95, 115, 130F 0, 50, 60, 70, 80C 32, 125, 145, 160, 175F 0, 75, 85, 95, 105C 32, 168, 185, 200, 220F 0, 100, 110, 130, 150C 32, 205, 240, 275, 310F SOLIDIFICATION POINT ASTM S91C-03 IP CAT NO 1224-S-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 20, 30, 40, 50C KINEMATIC VISCOSITY ASTM S120C-03 IP CAT NO 1096Y-S-C CERTIFICATION TEST POINTS Certified @ ASTM specified test points of 0, 40, 41C n 1042-S-C 1714 Page 29 FRACTIONAL DEGREE PRECISION LABORATORY THERMOMETERS Page 31 KESSLER Precision Laboratory Thermometers are supplied in yellow back glass with PERMETCH Brand permanent pigmentation of graduations. All of these instruments are aged and annealed for extended accurate service life, and are suitable for certification. EXTREME PRECISION THERMOMETERS CELSIUS RANGES - (MERCURY CAT NO 2100 2102 2104 2106 + + + + TYPE Extreme Extreme Extreme Extreme Precision Precision Precision Precision CELSIUS RANGES - (MERCURY CAT NO 2100-3 2102-3 2104-3 2106-3 + + + + TYPE Extreme Extreme Extreme Extreme Precision Precision Precision Precision FILLED) -1 to 51OC -1 to 101OC -1 to 101OC -1 to 201OC FILLED) 2118 2120 2122 2124 + + + + TYPE Extreme Extreme Extreme Extreme Precision Precision Precision Precision -1 to 51OC -1 to 101OC -1 to 101OC -1 to 201OC FAHRENHEIT RANGES- (MERCURY CAT NO 2118-3 2120-3 2122-3 2124-3 + + + + TYPE Extreme Extreme Extreme Extreme Precision Precision Precision Precision FILLED) TEMP RANGE +30 +30 +30 +30 to to to to DIV 0.1 0.2 0.1 0.2 124 F 124OF 220OF 394OF O DIV 0.1 0.2 0.1 0.2 TOTAL 0.2 0.1 0.2 0.5 FILLED) PARTIAL DIV to to to to IMMERSION LENGTH IMMERSION 457mm 457mm 610mm 610mm Total Total Total Total 124 F 124OF 220OF 394OF O 457mm 457mm 610mm 610mm 76mm 76mm 76mm 76mm IMMERSION DIV TEMP RANGE +30 +30 +30 +30 LENGTH PARTIAL IMMERSION TEMP RANGE FAHRENHEIT RANGES- (MERCURY CAT NO TOTAL IMMERSION TEMP RANGE 0.2 0.1 0.2 0.5 LENGTH 457mm 610mm 610mm 610mm IMMERSION Total Total Total Total IMMERSION LENGTH 457mm 610mm 610mm 610mm IMMERSION 3” 3” 3” 3” + ITEMS MARKED WITH + AVAILABLE IMMEDIATELY FROM STOCK WITH NIST TRACEABLE CERTIFICATE OF CALIBRATION. ADD “-C” TO CAT. NO. EXTREME PRECISION THERMOMETERS (NON-MERCURIAL) CELSIUS RANGES - TOTAL IMMERSION CAT NO 2100-RL 2102-RL 2104-RL 2106-RL TYPE Extreme Extreme Extreme Extreme Precision Precision Precision Precision TEMP RANGE -1 to 51OC -1 to 101OC -1 to 101OC -1 to 201OC DIV LENGTH IMMERSION DIV LENGTH IMMERSION 0.1 0.2 0.1 0.2 457mm 457mm 610mm 610mm Total Total Total Total CELSIUS RANGES - PARTIAL IMMERSION CAT NO 2100-3RL 2102-3RL 2104-3RL 2106-3RL TYPE Extreme Extreme Extreme Extreme Precision Precision Precision Precision TEMP RANGE -1 to 51OC -1 to 101OC -1 to 101OC -1 to 201OC 0.1 0.2 0.1 0.2 457mm 457mm 610mm 610mm 76mm 76mm 76mm 76mm 2100 2100-RL FRACTIONAL DEGREE PRECISION THERMOMETERS EXTREME PRECISION THERMOMETERS (NON-MERCURIAL) FAHRENHEIT RANGES - TOTAL CAT NO TYPE 2118-RL 2120-RL 2122-RL 2124-RL Extreme Extreme Extreme Extreme Precision Precision Precision Precision IMMERSION TEMP RANGE +30 +30 +30 +30 FAHRENHEIT RANGES - PARTIAL CAT NO TYPE 2118-3RL 2120-3RL 2122-3RL 2124-3RL Extreme Extreme Extreme Extreme Precision Precision Precision Precision to to to to 124OF 124OF 220OF 394OF DIV LENGTH IMMERSION DIV LENGTH IMMERSION 0.2 0.1 0.2 0.5 457mm 610mm 610mm 610mm Total Total Total Total IMMERSION TEMP RANGE +30 +30 +30 +30 to to to to 124OF 124OF 220OF 394OF 0.2 0.1 0.2 0.5 457mm 610mm 610mm 610mm 3” 3” 3” 3” + ITEMS MARKED WITH + AVAILABLE IMMEDIATELY FROM STOCK WITH NIST TRACEABLE CERTIFICATE OF CALIBRATION. ADD “-C” TO CAT. NO. MANUFACTURING CHEMISTS ASSOCIATION “R” SERIES SEQUENTIAL CELSIUS RANGES FOR GENERAL RESEARCH AND TESTING PROCEDURES. CAT NO TYPE 2150 2152 2154 2156 Precision Precision Precision Precision TEMP RANGE M.C.A.R-1 M.C.A.R-2 M.C.A.R-3 M.C.A.R-4 DIV -36 to 54OC -10 to 80OC 70 to 160OC 140 to 230OC LENGTH IMMERSION LENGTH IMMERSION 0.2 0.2 0.2 0.2 406mm 406mm 406mm 406mm 76mm 76mm 76mm 76mm CELSIUS - PRECISION TEST - PARTIAL IMMERSION THIS THERMOMETER SERIES HAS BEEN DESIGNED IN CONJUNCTION WITH THE THERMOMETER COMMITTEE OF ONE OF THE CHEMICAL INDUSTRY’S LARGEST COMPANIES TO SATISFY THEIR NATIONWIDE REQUIREMENTS FOR CLOSE, ACCURATE READINGS IN BOTH LABORATORY AND PRODUCTION WORK. CAT NO TYPE 2200 2202 2204 2206 2208 2210 2212 2214 Precision Precision Precision Precision Precision Precision Precision Precision TEMP RANGE JL-1 JL-2 JL-3 JL-4 JL-5 JL-6 JL-7 JL-8 DIV -36 to 30OC -5 to 30OC 25 to 60OC 55 to 90OC 85 to 120OC 115 to 185OC 180 to 250OC 245 to 420OC 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.5 406mm 406mm 406mm 406mm 406mm 406mm 406mm 406mm 76mm 76mm 76mm 76mm 76mm 76mm 76mm 76mm FAHRENHEIT - PRECISION TEST - PARTIAL IMMERSION DESIGNED AS THE FAHRENHEIT COUNTERPARTS OF OUR POPULAR 2200 SERIES (ABOVE), THIS SERIES ALLOWS CLOSE, ACCURATE READINGS IN BOTH LABORATORY AND PRODUCTION WORK. CAT NO 2300 2302 2304 2306 2308 2310 2312 2314 2216 2316 TYPE Precision Precision Precision Precision Precision Precision Precision Precision TEMP RANGE -36 to 85OF 23 to 86OF 77 to 140OF 131 to 194OF 185 to 248OF 239 to 365OOF 356 to 482OF 473 to 788OF DIV 0.5 0.2 0.2 0.2 0.2 0.5 0.5 1.0 COMPLETE SET OF THE CELSIUS ABOVE THERMOMETERS IN VELVET-LINED CASE COMPLETE SET OF THE FAHRENHEIT ABOVE THERMOMETERS IN VELVET-LINED CASE LENGTH 406m 406mm 406mm 406mm 406mm 406mm 406mm 406mm IMMERSION 3” 3” 3” 3” 3” 3” 3” 3” 2214 2302 Page 33 LABORATORY THERMOMETERS PRECISION GRADE Page 35 Manufactured for general testing and laboratory procedures where an ASTM thermometer is not specified. Supplied with PERMETCH brand permanent pigmentation of graduations. Manufactured with greatest ease for extended and long service life. All instruments of this series comply with NIST Special Publication 250-23 and are eligible for certification. MERCURY THERMOMETERS (YELLOW GLASS) CELSIUS RANGES TOTAL IMMERSION RANGE DIV CAT NO. 2048T 2050T 2052T -35to 50OC -20 to 110OC -20 to 150OC 1 1 1 2054T 2056T 2058T 2060T 2062T 2064T* -10 -10 -10 -10 -10 -10 1 1 1 1 1 2 to to to to to to 210OC 250OC 310OC 360OC 400OC 510OC LENGTH 305mm 305mm 305mm 76MM IMMERSION CAT NO. RANGE DIV LENGTH 3” IMMERSION CAT NO. RANGE DIV LENGTH 2048 2050 2052 2053 2054 2056 2058 2060 2062 2064* 381mm 381mm 381mm 406mm 406mm 406mm -35 to 50OC -20 to 110OC -20 to 150OC -5 to 150OC 0 -10 to 210OC -10 to 250OC -10 to 310OC -10 to 360OC -10 to 400OC -10 to 510OC 1 1 1 .5 1 1 1 1 1 2 305mm 305mm 305mm 381mm 381mm 381mm 381mm 406mm 406mm 406mm FAHRENHEIT RANGES TOTAL IMMERSION RANGE DIV CAT NO. 2000T 2001T 2002T 2003T 2004T 2005T 2006T 2007T 2008T 2010T 2012T 2016T 2022T* 0 to 120OF -30 to 120OF 0 to 150OF -4 to 230OF 30 to 220OF 0 to 300OF 30 to 300OF 0 to 400OF 30 to 400OF 30 to 500OF 30 to 600OF 30 to 750OF 30 to 1000OF DUAL SCALE (CELSIUS CAT NO. 3050T 3052T 3056T 3060T AND LENGTH 1 1 1 2 1 2 1 2 2 2 2 2 5 12” 12” 12” 12” 15” 12” 15” 12” 15” 15” 15” 16” 16” 2000 2001 2002T 2003T 2004 2005 2006 2007 2008 2010 2012 2016 2022 0 to 120OF -30 to 120OF 0 to 150OF -4 to 230OF 30 to 220OF 0 to 300OF 30 to 300OF 0 to 400OF 30 to 400OF 30 to 500OF 30 to 600O F 30 to 750OF 30 to 1000OF 1 1 1 2 1 2 1 2 2 2 2 2 5 12” 12” 12” 12” 15” 12” 15” 12” 15” 15” 15” 16” 16” FAHRENHEIT) TOTAL IMMERSION RANGE DIV -20/110OC & 0/230OF -20/150OC & 0/300OF -10/260OC & 30/500OF -10/360OC & 30/700OF 1C 1C 1C 1C 2F 2F 2F 2F LENGTH CAT NO. 12” 12” 15” 16” 3062T -10/400OC & 30/750OF 1C 2F 16” * FABRICATED OF WHITE BACK BOROSILICATE GLASS FOR ACCURACY AND STABILITY. 76MM IMMERSION RANGE DIV 3050 3052 3056 3060 -20/110OC & 0/230OF -20/150OC & 0/300OF -10/260OC & 30/500OF -10/360OC & 30/700OF 1C 1C 1C 1C 3062 -10/400OC & 30/750OF 1C 2F LENGTH 2F 2F 2F 2F 12” 12” 15” 16” 16” MERCURY FILLED TEFLON ENCAPSULATED* AN ACCURATE LIQUID-IN-GLASS THERMOMETER, HERMETICALLY SEALED WITHIN A CAPSULE OF TEFLON TUBING. R E S I S T S B R E A K A G E – I M P E R V I O U S T O A C I D -C O N T A M I N A T I O N F R E E . CELSIUS RANGES CAT NO 2026T 2028T 2030T 2031T TOTAL IMMERSION TEMP RANGE DIV -20 to 10OC -20 to 150OC -10 to 210OC -10 to 250OC 1 1 1 1 LENGTH 305mm 305mm 381mm 381mm 76MM IMMERSION CAT NO TEMP RANGE DIV 2026 2028 2030 2031 -20 -20 -10 -10 to to to to 110OC 150OC 210OC 250OC * Most thermometers in this catalog, including ASTM thermometers, with top ranges not exceeding approximately 260C (or 500F) may be Teflon encapsulated. Please consult factory for specific details. 1 1 1 1 LENGTH 305mm 305mm 381mm 381mm 2056 LABORATORY PRECISION GRADE MERCURY FILLED TEFLON ENCAPSULATED (CONTINUED) FAHRENHEIT RANGES CAT NO TOTAL IMMERSION TEMP RANGE DIV 2032T 2034T 2036T 2037T -4 to 230OF 0 to 300OF 30 to 400OF 30 to 500OF 2 2 2 2 LENGTH 12” 12” 15” 15” CAT NO 2001-TE 2032 2034 2036 2037 76MM IMMERSION TEMP RANGE DIV LENGTH -30 to 120OF -4 to 230OF2 0 to 300OF2 30 to 400OF 30 to 500OF 1 1 1 2 2 12” 12” 12” 15” 15” NON-MERCURIAL SAFETY LAB THERMOMETERS (WHITEBACK) IN RECOGNITION OF INCREASED WORKPLACE AND ENVIRONMENTAL CONCERNS, KESSLER HAS INTRODUCED AN EXPANDED LINE OF NON-MERCURIAL THERMOMETERS. THESE INSTRUMENTS PROVIDE THE ACCURATE, RELIABLE READINGS EXPECTED OF A KESSLER THERMOMETER, WITH AN ENVIRONMENTALLY SAFE ALCOHOL OR MINERAL SPIRITS FILLING. SEE ARTICLE LOCATED IN BACK OF CATALOG “THE NEW NON-MERCURIAL THERMOMETERS - JUST HOW GOOD ARE THEY?” NON-MERCURIAL CELSIUS RANGES CAT NO. 305mm 305mm 305mm TOTAL IMMERSION MEDIUM RANGE DIV -200 to 30OC -100 to 50OC 76MM IMMERSION MEDIUM RANGE DIV LENGTH LENGTH CAT NO. 1 1 350mm 305mm 3134-3 3130-3 Alcohol Alcohol -100 to 50OC -50 to 50OC 3300 Alcohol -35 to 50OC 1 1 3136 3134 Pentane Alcohol 3130 Alcohol - 50 to 50OC 1 305mm 3300T Alcohol - 35 to 50OC 1 305mm 3302T Min Spirits - 20 to 110 C 1 305mm 3302 Min Spirits- 20 to 110OC 3304T 3306T Min Spirits Min Spirits -20 to 150 C -10 to 210OC 1 1 305mm 381mm 3304 3306 3308 Min Spirits Min Spirits Min Spirits -20 to 150 C -10 to 210OC -10 to 250OC O O O 1 1 1 1 305mm 1 305mm 381mm 381mm NON-MERCURIAL FAHRENHEIT RANGES CAT NO. 3138 3140 3316T 3320T 3324T 3328T TOTAL IMMERSION MEDIUM RANGE DIV Alcohol Alcohol Alcohol -150 to 120F -60 to 120F -30 to 120F 2 1 1 Min Spirits Min Spirits Min Spirits -4 to 230F -0 to 300F -30 to 400F 2 2 2 LENGTH 12” 12” 12” 12” 12” 15” 3” IMMERSION CAT NO. MEDIUM RANGE 3138-3 3140-3 3316 3317 3320 3324 3328 3330 Alcohol Alcohol Alcohol Alcohol Min Spirits Min Spirits Min Spirits Min Spirits -150 to 120F -60 to 120F -30 to 120F -30 to 120F -4 to 230F -0 to 300F -30 to 400F -30 to 485F DIV LENGTH 2 1 1 0.5 2 2 2 2 12” 12” 12” 12” 12” 12” 15” 15” NON-MERCURIAL TEFLON ENCAPSULATED CELSIUS RANGES CAT NO 2038T 2039T 2040T 2041T TOTAL IMMERSION TEMP RANGE DIV -35 to 50OC -20 to 1OOC -20 to 150OC 10 to 210OC 1 1 1 1 LENGTH 305mm 305mm 305mm 381mm 76MM IMMERSION CAT NO TEMP RANGE DIV LENGTH 2038 2039 2040 2041 -35 to 50OC -20 to 1OOC -20 to 150OC -10 to 210OC 1 1 1 1 305mm 305mm 305mm 381mm 3304 FAHRENHEIT RANGES CAT NO 2042T 2043T 2044T 2045T TOTAL IMMERSION TEMP RANGE DIV - 30 to 120OF -4 to 230OF 0 to 300OF 30 to 400OF 1 2 2 2 LENGTH 12” 12” 12” 15” 76MM IMMERSION CAT NO TEMP RANGE DIV LENGTH 2042 2043 2044 2045 2046 -30 to 120OF -4 to 230OF 0 to 300OF 30 to 400OF 30 to 485OF 1 2 2 2 2 12” 12” 12” 15” 15” 3134-3 Page 37 DEEP IMMERSION EXTENDED STEM & VARI-IMMERSION THERMOMETERS Page 39 Used for temperature measurement in deep vessels, flasks, ovens, sterilizers, incubators and similar equipment where the greater depth is required for accurate reading. All graduated in 1 degree divisions. MERCURY THERMOMETERS - YELLOW GLASS CELSIUS RANGES CAT NO 3098B 3098C 3099B 3099C 3100B 3100C 3100D 3101A 3101B 3101C 3101D 3102B 3102C 3102D 3103A 3103B 3103C 3103D 3104A 3104B 3104C 3104D 3106B 3106C 3106D 3108C TEMP RANGE -20 -10 -20 -10 -20 -10 -10 -20 -20 -10 -10 -20 -10 -10 -20 -20 -10 -10 -20 -20 -10 -10 -20 -10 -10 -10 to to to to to to to to to to to to to to to to to to to to to to to to to to 150C 250C 150C 250C 150C 250C 360C 110C 150C 250C 360C 150C 250C 360C 110C 250C 250C 360C 110C 150C 250C 360C 150C 250C 360C 250C DIV 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IMMERSION 100mm 100mm 100mm 125mm 125mm 152mm 152mm 152mm 203mm 203mm 203mm 225mm 225mm 225mm 255mm 255mm 255mm 255mm 305mm 305mm 305mm 305mm 457mm 457mm 457mm 610mm LENGTH 325mm 406mm 355mm 406mm 385mm 457mm 485mm 430mm 430mm 510mm 535mm 457mm 535mm 560mm 480mm 480mm 560mm 585mm 535mm 535mm 610mm 610mm 685mm 760mm 760mm 915mm NON-MERCURIAL EXTENDED STEM THERMOMETERS - RED SPIRIT, WHITE GLASS CAT NO 3098BRL 3098CRL 30998RL 3099CRL 3134-6 3130-6 3100BRL 3100CRL 3134-9 3130-9 31028RL 3I02CRL 3134-12 3130-12 3104BRL 3104CRL 3106BRL 3106CRL TEMP RANGE -20 to 150C -10 to 250C -20 to 150C -10 to 250C -100 to 50C -50 to 50C -20 to 150C -10 to 250C -100 to 50C -50 to 50C -20 to 150C -10 to 250C -100 to 50C -50 to 50C -20 to 150C -10 to 250C -20 to 150C -10 to 250C DIV 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IMMERSION 100mm 100mm 125mm 125mm 152mm 152mm 152mm 152mm 225mm 225mm 225mm 225mm 305mm 305mm 305mm 305mm 457mm 457mm LENGTH 325mm 406mm 355mm 430mm 385mm 385mm 385mm 457mm 457mm 457mm 457mm 535mm 535mm 535mm 535mm 610mm 685mm 760mm 3100C 3100C DEEP IMMERSION EXTENDED STEM & VARI-IMMERSION OVEN THERMOMETERS - MERCURY FOR USE WITH FREEZE, THELCO AND MOST LABORATORY OVENS. ITEMS MARKED ‘*’ HAVE AN ENLARGEMENT AT THE IMMERSION POINT. CAT NO TEMP RANGE DIV IMMERSION LENGTH 3112 -10 to 300C 1 305mm 610mm 3114* 3116* 3118* 3120* 3110 3122* 0 to 70C +20 to 110C 35 to 230C -10 to 250C -10 to 200C 0 to 350C 1 1 1 1 1 1 125mm 165mm 125mm 152mm 305mm 178mm 305mm 305mm 305mm 485mm 585mm 510mm VARI-IMMERSION THERMOMETERS KESSLER VARI-IMMERSION THERMOMETERS ARE DESIGNED FOR USE IN WORK WHERE A REQUIREMENT FOR ADJUSTABLE IMMERSION DEPTH EXISTS. THE VARIIMMERSION WHEN USED IN CONJUNCTION WITH KESSLER’S TEFLON 10/18 STANDARD TAPER #4103 ADJUSTABLE ADAPTER PERMIT A VACUUM CAPABILITY NEARLY AS HIGH AS A CONVENTIONAL GROUND GLASS JOINT. THE VARI-IMMERSION IS CONSTRUCTED OF TWO TYPES OF TUBING JOINED TOGETHER JUST BELOW THE SCALE. THE STEM PORTION IS OF AN EXTREMELY FINE BORE GLASS TO MINIMIZE CORRECTION FACTORS AT IMMERSION DEPTHS OTHER THAN THE MID-POINT OF THE STEM. THE SCALE PORTION IS OF A WIDE BORE GLASS TO FACILITATE READING OF THE INSTRUMENT AND TO ACCOMMODATE THE RANGES LISTED BELOW. EACH THERMOMETER IS FURNISHED WITH AN INSTRUCTION SHEET AND LISTING OF CORRECTION FACTORS. GRADUATED IN SINGLE DEGREE DIVISIONS WITH PERMETCH MARKINGS. MERCURY FILLED CAT NO. 4100B 4100C 4100D 4102B 4102C 4102D 4104B 4104C 4104D TEMP RANGE -20 -10 -10 -20 -10 -10 -20 -10 -10 to 150ºC to 250ºC to 360ºC to 150ºC o 250ºC to 360ºC to 150ºC to 250ºC to 360ºC IMMERSION 3” to 7” (76 - 178mm) 3” to 7” (76 - 178mm) 3” to 7” (76 - 178mm) 7” to 12” (178 - 305mm) 7” to 12” (178 - 305mm) 7” to 12” (178 - 305mm) 12” to 18” (305-457mm) 12” to 18” (305-457mm) 12” to 18” (305-457mm) NON-MERCURIAL FILLED CAT NO. 4100L 4100BRL 4100CRL 4102L 4102BRL 4102CRL 4104L 4104BRL 4104CRL TEMP RANGE -100 to 50ºC -20 to 150ºC -10 to 250ºC -100 to 50ºC -20 o 150ºC -10 to 250ºC -100 to 50ºC -20 to 150ºC -10 to 250ºC IMMERSION 3” to 7” (76 - 178mm) 3” to 7” (76 - 178mm) 3” to 7” (76 - 178mm) 7” to 12” (178 - 305mm) 7” to 12” (178 - 305mm) 7” to 12” (178 - 305mm) 12” to 18” (305-457mm) 12” to 18” (305-457mm) 12” to 18” (305-457mm) 4100B Page 41 ENVIRONMENTAL CHAMBER & SPECIALTY THERMOMETERS Page 43 A precision mercury-in-glass thermometer, graduated in 0.5 degree divisions. Teflon encapsulated for extra safety, mounted in a clear polycarbonate “bottle with mineral oil (sterilized sand for Oven model 1732) for use as a “heat sink” prevents rapid change of indication when chamber is opened for inspection. MEET EPA AND FDA REQUIREMENTS. NIST TRACEABLE ENVIRONMENTAL CHAMBER BOTTLE THERMOMETERS Our Environmental Chamber bottle Thermometers are offered in several ranges to observe critical temperatures, such as Ultra Low Freezers, Blood Bank Refrigerators, Ovens and Incubators. Each chamber-bottle thermometer is mounted in a square shaped plastic bottle filled with a medium to ensure accurate readings despite the opening and closing of instrument doors. The thermometers have engraved stems and are thoroughly annealed for long-lasting accuracy. Each thermometer has its own individual serial number and has been calibrated according to NIST standards. A certificate of accuracy is included with each thermometer making it traceable to NIST. We offer these thermometers with your choice of either mercury or mineral spirits, with a Teflon coating for safety, which absorbs shock, and will contain the glass and liquid should breakage occur. The Environmental Chamber bottle also has a double magnet attached on one side so it can be attached to the walls or doors of instruments to reduce space and breakage problems. MERCURY FILLED CAT NO 1716 1718 1719 1722 1723 1720 1732 1734 TEMP RANGE -30 to 0OC -5 to +15OC -5 to 20ºC +10 to +30OC +18 to +50ºC +30 to +45OC +20 to +130OC -5 to +205ºC DIV IMMERSION 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0 Total Total Total Total Total Total Total Total APPLICATION VERIFIED AT: APPLICATION VERIFIED AT: Freezers Refrigerators Blood Bank Incubators Incubators Incubators Oven Oven -20, 0C 0, 10C 0, 15C 15, 25C 20, 37C 37, 44.5C 85, 120C 0, 180C NON-MERCURIAL CAT NO 1715RL 1716RL 1718RL 1719RL 1722RL 1723RL 1720RL 1732RL TEMP RANGE -90 to +20ºC -30 to 0OC -5 to +15OC -5 to 20ºC +10 to +30OC +18 to +50ºC +30 to +45OC +20 to +130OC DIV IMMERSION Total Total Total Total Total Total Total Total Ultra low Freezers Freezers Refrigerators Blood Bank Incubators Incubators Incubators Oven 1734RL -5 to +205ºC 1.0 Total Oven 1 0.5 0.5 0.5 0.5 0.5 0.5 1.0 -60, 0C -20, 0C 0, 10C 0, 15C 15, 25C 20, 37C 37, 44.5C 85, 120C 0, 180C AUTOCLAVE CONSTRICTED CAPILLARY DESIGN REGISTERS HIGHEST TEMPERATURE ATTAINED UNTIL MANUALLY RESET. CAT NO 1530 1531 1532 TEMP RANGE 80 to 135OC 80 to 135OC 175 to 275OC FEATURE LENGTH DIV IMMERSION FEATURE LENGTH DIV IMMERSION FEATURE LENGTH DIV IMMERSION FEATURE LENGTH DIV IMMERSION FEATURE LENGTH 305mm 0.05 DIV IMMERSION FEATURE LENGTH DIV IMMERSION Maximum Registering Maximum Registering Maximum Registering 215mm 215mm 215mm 1.0 0.5 1.0 Total Total Total LIQUID Mercury Mercury Mercury COLIFORM INCUBATOR CAT NO 1700 1701 TEMP RANGE 34.5 to 46OC 34.5 to 46OC Arrows @ 35, 37, 44.5 Arrows, @ 35, 37, 44.5 240mm 152mm 0.1 0.1 76mm Total Mercury Mercury INCU-BLOK CAT NO 1702 1702RL TEMP RANGE 24 to 57OC 24 to 57OC Arrows @ 25, 30, 37, 56 Arrows @ 25, 30, 37, 56 175mm 175mm 0.5 0.5 35mm 35mm Mercury Mineral Spirits BLOOD BANK CAT NO 1704 1704RL TEMP RANGE -5 to 20OC -5 to 20OC 4 & 6C Marked with arrows 4 & 6C Marked with arrows 152mm 152mm 1.0 1.0 Total Total Mercury Mineral Spirits ENZYMOLOGY CAT NO 1706 TEMP RANGE 24 to 38OC Extremely Sensitive 95mm Mercury TRI-TEMP CAT NO 1708 1708RL TEMP RANGE 25, 37, 56OC 25, 37, 56OC Graduated only at test pts. Graduated only at test pts. 238mm 238mm 1702 1702RL 0.5 0.5 76mm 76mm Mercury Mineral Spirits ENVIRONMENTAL CHAMBER & SPECIALTY THERMOMETERS SPECIALTY THERMOMETERS 1530 Page 45 POCKET, MAXIMUM REGISTERING AND SPECIALTY THERMOMETERS Page 47 IN RESPONSE TO AN INCREASED AWARENESS OF ENVIRONMENTAL, WORKPLACE SAFETY, AND QUALITY CONTROL CONSIDERATIONS, KESSLER HAS EXPANDED ITS LINE OF TEFLON ENCAPSULATED THERMOMETERS. MAXIMUM REGISTERING THERMOMETERS ‘EASY SHAKER’ MAXIMUM THERMOMETERS THESE THERMOMETERS ARE USEFUL FOR DETERMINING THE HIGHEST TEMPERATURE ATTAINED IN LOCATIONS WHERE IT IS INCONVENIENT OR IMPOSSIBLE TO MEASURE THE TEMPERATURE WITH A CONVENTIONAL INDICATING THERMOMETER. DESIGNED WITH A CONSTRICTION IN THE MERCURY COLUMN, THESE THERMOMETERS WILL DISPLAY AND RETAIN THE HIGHEST TEMPERATURE OBTAINED UNTIL MANUALLY ‘SHAKEN DOWN’ OR RESET, SIMILAR TO A FEVER THERMOMETER. THERMOMETERS ARE FURNISHED IN PROTECTIVE CASES WITH A POCKET CLIP OR AS A REFILL THERMOMETER ONLY. LENGTH APPROXIMATELY 5-1/2” COMPLETE WITH CAT NO REFILL UNIT ONLY CAT NO TEMP RANGE CASE TEMP RANGE DIV 1510 0 to 220OF 2 1511 30 to 300OF 2 O 1512 30 to 300 F 2 O 1513 30 to 300 F 2 1514 30 to 300OF 2 1520 -20 to 110OC 1 1522 -5 to 200OC 2 SEE ALSO AUTOCLAVE MAXIMUM REGISTERING THERMOMETER ON PAGE # 1510R 1511R 1512R 1513R 1514R 1520R 1522R 0 to 220OF 30 to 300OF 30 to 300OF 30 to 300OF 30 to 300OF -20 to 110OC -5 to 200OC DIV 2 2 2 2 2 1 2 ‘HARD SHAKER’ MAXIMUM THERMOMETERS IDENTICAL IN FUNCTION TO THE ABOVE MENTIONED THERMOMETERS, THESE UNITS ARE DESIGNED WITH A SEVERELY RESTRICTED CAPILLARY TO RESIST VIBRATION AND ARE COMMONLY USED IN SERVICE SUCH AS OIL WELL LOGGING AND GEOTHERMAL EXPLORATION. CANNOT BE RESET MANUALLY - REQUIRES A CENTRIFUGE TO RESET! CAT NO TEMP RANGE DIV LENGTH CAT NO TEMP RANGE DIV LENGTH 1636 1640 1642 1644 1662 -20 to 120OC 14 to 166OC 40 to 206OC 90 to 260OC 200 to 350OC 2 2 2 2 2 6.25” 5” 6.25” 6.25” 5” 1638 1641 1643 1645 14 to 106OC 25 to 200OC 0 to 200OF 90 to 260OF 2 2 2 2 6.25” 6.25” 5.5” 5” 1540 1544 1548 1552 1556 1559 1562 60 to 220OF 0 to 300OF 100 to 300OF 100 to 400OF 200 to 400OF 200 to 500OF 400 to 650OF 2 2 2 2 2 2 2 5.5” 5.5” 5.5” 5.5” 5.5” 5.5” 5” 1542 1546 1550 1554 1558 1560 1564 60 to 220OF 0 to 300OF 60 to 330OF 100 to 400OF 200 to 500OF 200 to 500OF 350 to 650OF 2 2 2 2 2 2 2 6.25” 6.25” 5” 6.25” 5” 6.25” 6.25” MIN-MAX THERMOMETER THERMOMETER REGISTERS HIGH AND LOW READINGS FROM LAST SETTING. PLASTIC CASE. PUSH BUTTON RESET. DUAL SCALE: -40/120ºF & -40/50ºC (MERCURY FILLED) CAT. NO. 5460 THERMOMETER REGISTERS HIGH AND LOW READINGS FROM LAST SETTING. PLASTIC CASE. MAGNETIC RESET. DUAL SCALE: -40/120ºF & -40/50ºC (MERCURY FILLED) CAT. NO. 5465 POCKET THERMOMETERS POCKET THERMOMETERS ARE FURNISHED IN PROTECTIVE CASES WITH A POCKET CLIP OR AS A REFILL THERMOMETER ONLY. LENGTH APPROXIMATELY 5-1/2”. 5465 5460 1522 MERCURY FILLED TEMP. RANGE DIV COMPLETE CASE W/METAL -35 to 50OC -10 to 110OC -30 to 120OF +30 to 120OF 0 to 220ºF 0 to 300ºF 100 to 450ºF 1 1 2 1 2 2 5 COMPLETE CASE W/PLASTIC 3147 3148 3150 3152 3154 3156 3158 COMPLETE FACE ARMOR REFILL W/OPEN 3147-B 3148-B 3150-B 3152-B 3154-B 3156-B 3158-B 3147-A 3148-A 3150-A 3152-A 3154-A 3156-A 3158-A 3147-R 3148-R 3150-R 3152-R 3154-R 3156-R 3158-R NON-MERCURIAL - (MINERAL SPIRITS FILLED) TEMP. RANGE DIV COMPLETE CASE W/METAL COMPLETE CASE W/PLASTIC COMPLETE FACE ARMOR REFILL W/OPEN -40 to 50OC -10 to 110OC -40 to 120ºC -30 to 120OF 0 to 120ºF 0 to 220ºF 1 1 2 2 1 2 3142SP 3148SP 3149SP 3150SP 3151SP 3154SP 3142SP-B 3148SP-B 3149SP-B 3150SP-B 3151SP-B 3154SP-B 3142SP-A 3148SP-A 3149SP-A 3150SP-A 3151SP-A 3154SP-A 3142-RSP 3148-RSP 3149-RSP 3150-RSP 3151-RSP 3154-RSP 0 to 300ºF 2 3156SP 3156SP-B 3156SP-A 3156-RSP 3148 ASPHALT, SOIL, AND CONCRETE TESTING THERMOMETERS CAT NO 6300 6308 6310 6320 6400 DESIGNATION Asphalt Testing Asphalt Testing Asphalt Testing Concrete, soils pocket Concrete TEMP RANGE GRAD 50 to 450OF 10 to 310OC 50 to 600OF 0 to 120OF 0 to 120OF 5 2 5 1 1 IMMERSION Stem Stem Stem Stem Bulb SPECIAL FEATURES With penetration armor With penetration armor With penetration armor With penetration armor w/pocket case, plated bulb DEEP FRY (FAST FOODS) CALIBRATION THERMOMETERS CAT NO 6420 6420R DESIGNATION Fry calibration Fry calibration TEMP RANGE GRAD 120 to 430OF 120 to 430OF 2 2 IMMERSION SPECIAL FEATURES 4-6” Teflon Encapsulated, w/armor case, 16” lg. 4-6” Refill thermometer only WEATHER BUREAU METEOROLOGICAL THERMOMETERS CAT NO 6500S 6500 6502 6520 6522 6540 6542 6560 6562 DESIGNATION TEMP RANGE USWB Sling Psychrometer -30 to 120OF USWB Sling Psychrometer -20 to 120OF USWB Sling Psychrometer -30 to 50OC USWB Maximum Thermometer -20 to 120OF USWB Maximum Thermometer -25 to 65OC USWB Minimum Thermometer -40 to 110OF USWB Minimum Thermometer -40 to 45OC USWB ‘Exposed’ -38 to 110OF USWB ‘Exposed’ -38 to 45OC FOR THERMOMETER OR PSYCHROMETER REFILL TUBE ONLY ADD ‘R’ TO CATALOG NUMBER. DIV 1 1 1 1 1 1 1 1 1 IMMERSION TTL TTL TTL TTL TTL TTL TTL TTL TTL SPECIAL FEATURES POCKET & MAXIMUM REGISTERING THERMOMETERS POCKET CASE ONLY CAT NO. 3155. w/frame, handle, wicks w/frame, handle, wicks w/frame, handle, wicks w/stainless backplate w/stainless backplate w/stainless backplate w/stainless backplate w/stainless backplate w/stainless backplate 6300 6500 Page 49 JOINTED THERMOMETERS Page 51 KESSLER ST (Standard Taper) jointed thermometers are uniquely fabricated by enlarging and molding the stem glass to the required size, then precision grinding to a true standard taper for a perfect fit. This style of fabrication avoids the inherent weaknesses found in ordinary jointed thermometers built from 3 separate pieces of glass. 10/30 ST JOINTED THERMOMETERS (MERCURY FILLED) FABRICATED FROM YELLOW GLASS, ALL IN 1 DEGREE C DIVISIONS. STEM LENGTH 1” (25mm) 1.5” (38mm) 2” (51mm) 2.5” (63mm) 3” (76mm) 4” (100mm) 5” (125mm) 6” (152mm) 7” (178mm) 7.5” (190mm) 8” (203mm) 8.5” (215mm) 9” (225mm) 10” (255mm) 11” (280mm) 12” (305mm) -20 TO 110OC 3998A --------3999A --------4000A 4001A 4002A 4003A 4004A 4005A 4006A 4007A 4008A 4009A 4010A 4011A -20 TO 150OC 3998B --------3999B --------4000B 4001B 4002B 4003B 4004B 4005B 4006B 4007B 4008B 4009B 4010B 4011B -10 TO 250OC 3998C 3998.5C 3999C 3999.5C 4000C 4001C 4002C 4003C 4004C 4005C 4006C 4007C 4008C 4009C 4010C 4011C -10 TO 360OC 3998D --------3999D --------4000D 4001D 4002D 4003D 4004D 4005D 4006D 4007D 4008D 4009D 4010D 4011D 10/30 ST JOINTED THERMOMETERS (NON-MERCURIAL) FABRICATED FROM WHITE GLASS, ALL IN 1 DEGREE C DIVISIONS, MINERAL SPIRITS FILLED. STEM LENGTH 1” (25mm) 2” (51mm) 3” (76mm) 4” (100mm) 5” (125mm) 6” (152mm) 7” (178mm) 7.5” (190mm) 8” (203mm) 8.5” (215mm) 9” (225mm) 10” (255mm) 11” (280mm) 12” (305mm) -20 TO 110OC ----------------------------------------------------------------------------------------------------------------- -20 TO 150OC 3998BRL 3999BRL 4000BRL 4001BRL 4002BRL 4003BRL 4004BRL 4005BRL 4006BRL 4007BRL 4008BRL 4009BRL 4010BRL 4011BRL -10 TO 250OC 3998CRL 3999CRL 4000CRL 4001CRL 4002CRL 4003CRL 4004CRL 4005CRL 4006CRL 4007CRL 4008CRL 4009CRL 4010CRL 4011CRL 10/18 ST JOINTED THERMOMETERS FABRICATED FROM YELLOW GLASS, ALL IN 1 DEGREE C DIVISIONS. STEM LENGTH 1” 2” 3” 4” 5” (25mm) (51mm) (76mm) (100mm) (125mm) -20 TO 110OC ----------------------------------------- -20 TO 150OC 4098B 4099B ------------------------- -10 TO 250OC 4098C 4099C 4500C 4501C 4502C -10 TO 360OC 4098D 4099D 4500D ----------------- 4003CRL 4099C 4003D JOINTED THERMOMETERS 10/30 ST JOINTED THERMOMETERS (TEFLON ENCAPSULATED) NEW FROM KESSLER, THESE TEFLON ENCAPSULATED THERMOMETERS REDUCE CHANCES OF JOINT SEIZURE FROM GLASS-TO-GLASS BINDING, AND GREATLY DECREASE CHANCES OF CONTAMINATION FROM SPILLED MERCURY OR GLASS FRAGMENTS. STEM LENGTH 1” 2” 3” 4” 5” 6” (25mm) (51mm) (76mm) (100mm) (125mm) (152mm) -20 TO 150OC 4400B 4402B 4404B 4406B 4408B 4410B -10 TO 250OC 4400C 4402C 4404C 4406C 4408C 4410C 7/12 ST JOINTED ‘MICRO’ THERMOMETERS FABRICATED FROM WHITE GLASS, 150C IN 1 DEGREE C DIVISIONS, 300C IN 2 DEGREE C DIVISIONS STEM LENGTH 2cm (20mm) 3cm (30mm) 4cm (40mm) 5cm (50mm) 6cm (60mm) 7cm (70mm) 8cm (80mm) 9cm (90mm) 10cm (100mm) 0 TO 150OC 4206E 4208E 4210E 4212E 4214E 4216E 4218E 4220E 4222E 0 TO 300OC 4206F 4208F 4210F 4212F 4214F 4216F 4218F 4220F 4222F TEFLON ADJUSTABLE 10/18 ADAPTERS 10/18 STANDARD TAPER ADJUSTABLE TEFLON ADAPTER. ALLOWS VARI-IMMERSION THERMOMETERS TO BE USED IN 10/18 OR 10/30 FEMALE JOINTS. CAT NO. 4103 4206E Page 53 GAUGING EQUIPMENT 15 14 13 12 11 10 9 8 K OLO W AT E R FI R N D IN KUT G KOLOR KUT PA ST 7 6 5 E 4 GASOLINE GAUGING PASTE 3 2 Page 55 OIL SAMPLERS MIDTANK SAMPLER MAY BE USED TO OBTAIN STRATIFICATION SAMPLE FROM ANY POINT IN TANK OR PRESET TO OBTAIN SAMPLE STARTING ANY PLACE UP TO 12” FROM TANK BOTTOM. LOWERED BY MEANS OF TAPE OR CHAIN IN OPEN POSITION. A SHARP TUG ON THE LINE CLOSES THE VALVE AND SECURES SAMPLE. CAT NO MTS-12 - WITH 12” GRADUATED ACRYLIC CYLINDER CAT NO MTS-15 - WITH 16” GRADUATED ACRYLIC CYLINDER “BACON BOMB” BOTTOM SAMPLERS FOR SAMPLING OF PETROLEUM IN ACCORDANCE WITH ASTM METHOD D-275. ERROR FREE ONE LINE PICKUP OF BOTTOM SAMPLE. MAY ALSO BE USED FOR MIDPOINT SAMPLING WITH ADDITION OF SECONDARY ‘TRIP’ LINE. CAT NO 277 277A 277B 277C 277D CAPACITY 32oz 16oz 8oz 4oz 4oz Slimline Pencil type (1 1/8” OD fits narrow fill pipes WEIGHTED SAMPLER 277A WEIGHTED COPPER BEAKER OF NICKEL PLATED BRASS CONSTRUCTION. ONE QUART CAPACITY WITH CORK CLOSURE AND BRASS CHAIN SECURING CORK TO HANDLE CAT NO WCB-1 - 3/4” OPENING CAT NO WCB-2 - 1 1/2” OPENING GAUGING PASTE (FROM KOLOR KUT) WEIGHTED COPPER BEAKER OF NICKEL PLATED BRASS CONSTRUCTION. ONE QUART CAPACITY WITH CORK CLOSURE AND BRASS CHAIN SECURING CORK TO HANDLE CAT NO WFP - WATER FINDING PASTE CAT NO GGP - GASOLINE GAUGING PASTE WFP LUFKIN GAUGING TAPES GGP CHROME-NUBIAN (CN) STYLE (HALF OF THE TAPE FACE IS CHROME, HALF FLAT BLACK) PERMITS GAUGING OF BOTH LIGHT AND DARK PRODUCTS WITH ONE TAPE. MTS-15 INNAGE TAPES (REQUIRE 590 SERIES PLUMB BOB) LENGTH ENGLISH (FT & INCHES) ONLY ENGLISH-METRIC 25’ 33’ 50’ 66’ 75’ 100’ 50’ 50’ 66’ CN1290SF590 CN1291SF590 CN1293SF590 CN1294SF590 CN1295SF590 CN1296SF590 CN1293SD590 CN1293SF587 CN1294SF587 N/A N/A CN1293SMEF590 CN1294SMEF590 N/A CN1296SMEF590 Graduated in feet and tenths CN1293SMEF587 CN1294SMEF587 DUAL SCALE CN1295SF590 (50’ & 15m) (66’ & 20m) (100’ & 30m) (50’ & 15m) (66’ & 20m) PLEASE NOTE: THE ABOVE NUMBERS SPECIFY TAPES COMPLETE WITH REEL AND HANDLE. TO ORDER REFILL TAPE ONLY, ADD PREFIX ‘0’ BEFORE CATALOG NUMBER. TAPES DO NOT INCLUDE BOB. ORDER BOB SEPARATELY! LUFKIN GAUGING BOBS ENGRAVED BRASS PLUMB BOBS FOR USE WITH THE ABOVE GAUGING TAPES. 6” INNAGE BOBS 6” OUTAGE (ULLAGE) BOBS CAT NO. FEATURE CAT NO. FEATURE 590 590G 590GME 590SD Ungraduated Graduated in inches to 1/8” Graduated in inches and mm Use with SD Tapes 587 587-1/2 587GME Graduated in inches Graduated in inches to 1/8” Graduated in metric & english 590SD 590G GAUGING EQUIPMENT CYLINDRICAL BRASS CUPCASE GAUGING THERMOMETERS 12” LENGTH BY 1-3/4” DIAMETER PRINTED SCALE WITH LARGE, VIVID LINES AND NUMERALS FOR QUICK, EASY READING AT A GLANCE. TEMP RANGE DIV -10 to 110OF 0 to 200OF 1 1 COMPLETE WITH CASE 5103 5104 REFILL UNIT ONLY 5103R 5104R ENGRAVED STEM LINES AND NUMBERS ETCHED INTO THE GLASS FOR EVEN GREATER ACCURACY. TEMP RANGE DIV 0 to 90OF +10 to 100OF -10 to 100OF 0 to 200OF 0 to 220OF 20 to 260OF 100 to 300OF +30 to 450OF -50 to 50OC -35 to 50OC -30 to 100OC 0.5 0.5 1 1 1 1 1 2 0.5 0.5 1 COMPLETE WITH CASE 5108ES 5109ES 5103ES 5104ES 5106ES 5107ES 5105 5115ES 5110ES 5114ES 5112ES REFILL UNIT ONLY 5108RES 5109RES 5103RES 5104RES 5106RES 5107RES 5105R 5115RES 5110RES 5114RES 5112RES 12” LENGTH BY 1” DIAMETER ENGRAVED STEM LINES AND NUMBERS ETCHED INTO GLASS FOR ACCURACY. NARROW 1” OD PERMITS INSERTION THROUGH 1 1/2” FILL PIPES. TEMP RANGE DIV -20 to 120OF -10 to 220OF 30 to 320OF 35 to 50OC 1 2 2 0.5 COMPLETE WITH CASE 5100 5101 5102 5111 REFILL UNIT ONLY 5100R 5101R 5102R 5111R 10” LENGTH BY 1” DIAMETER ENGRAVED STEM LINES AND NUMBERS ETCHED INTO GLASS FOR ACCURACY. NARROW 1” OD PERMITS INSERTION THROUGH 1 1/2” FILL PIPES. TEMP RANGE DIV -20 to 120OF -10 to 220OF +30 to 320OF 1 2 2 COMPLETE WITH CASE 5100 5101-10 5102-10 REFILL UNIT ONLY 5100R 5101R-10 5102R-10 5104 Page 57 ASTM TANK GAUGING THERMOMETERS ASTM AND SIMILAR (NO ASSIGNED ASTM NUMBER BUT MANUFACTURED TO THE IDENTICAL SPECIFICATIONS) TANK THERMOMETERS MAY BE FURNISHED IN ANY OF THE THREE FOLLOWING CASES OR AS REFILL UNITS ONLY. STANDARD CASE (CASE ONLY - CAT NO 1259) LONG ACCEPTED FAVORITE FOR GAUGING AS SPECIFIED IN ASTM METHOD D270 MARINE CASE (CASE ONLY - CAT NO 1259CM) SPECIALLY ADAPTED WITH GROUNDING PLATE TO CONDUCT STATIC BUILDUP TO TAPE AND AWAY FROM PRODUCT. DEFLECTOR LID ON CUP OPENS ON DESCENT, CLOSES ON ASCENT TO PREVENT ‘WASHING’ EFFECT OF UNIT BEING DRAWN UP THROUGH PRODUCT AT LESSER DEPTHS. TANKMASTER CASE (CASE ONLY - CAT NO 1259TM) THE MOST VERSATILE AND WELL DESIGNED GAUGING THERMOMETER CASE ON THE MARKET TODAY. CONSTRUCTED OF DUPONT ZYTEL, IT IS IMPERVIOUS TO CHEMICALS WHICH ATTACK CONVENTIONAL MATERIALS. WILL NOT GENERATE OR CONDUCT STATIC ELECTRICITY. WEIGHTED TO AID RAPID DESCENT IN HEAVY PRODUCTS. OVERSIZED 120ML CAPACITY CUP PLUS INSULATING PROPERTIES OF ZYTEL OFFER BETTER HEAD RETENTION CAPABILITIES. EXCEEDS REQUIREMENTS OF ASTM D-270. FOR CONTINUOUS USE TO 240F, INTERMITTENT USE TO 300F. ACCEPTS THERMOMETERS WITH VARYING TOP FINISHES. FAHRENHEIT RANGES (YELLOW ASTM 58F 97F 59F 98F 130F 60F TEMP RANGE -30 to 120OF 0 to 120OF 0 to 120OF 0 to 180OF 60 to 180OF 0 to 220OF 20 to 220OF 20 to 260OF 170 to 500OF LENS TUBING STANDARD*) DIV 1 1 0.5 1 1 0.5 1 1 2 W/STANDARD 1250 1262C 1263C 1254 1264C 1240C 1261C 1294C 1258 CASE W/MARINE CASE W/TANKMASER CASE REFILL ONLY CASE W/MARINE CASE W/TANKMASER CASE REFILL ONLY 1252CM 1262CM 1263CM 1256CM 1264CM 1240CM 1261CM 1294CM 1260CM 1252TM 1262TM 1263TM 1256TM 1264TM 1240TM 1261TM 1294TM 1260TM 1252 1262 1263 1256 1264 1240 1261 1294 1260 CELSIUS RANGES (YELLOW LENS TUBING STANDARD*) ASTM 58C 97C 98C 59C 130C 60C TEMP RANGE -50 to 50OC -34 to 49OC -18 to 49OC 16 to 82OC -18 to 82OC -7 to 110OC 0 to 150OC 77 to 260OC DIV 0.5 0.5 0.5 0.5 0.5 0.5 1 1 W/STANDARD 1247C 1248C 1244C 1246C 1253C 1271C 1242C 1257C 1247CM 1248CM 1244CM 1246CM 1253CM 1271CM 1242CM 1257CM 1247TM 1248TM 1244TM 1246TM 1253TM 1271TM 1242TM 1257TM 1247 1248 1244 1246 1253 1271 1242 1257 * ANY OF THE ABOVE MAY BE FURNISHED WITH RED READING LENS AT ADDITIONAL COST. TO ORDER, ADD SUFFIX “RRL” TO CATALOG NUMBER. SMALL CUP & WOODBACK TANK THERMOMETERS SIMILAR IN APPEARANCE AND CONSTRUCTION TO ASTM THERMOMETERS ABOVE BUT WITH SMALLER CUP, SHORTER OVERALL LENGTH. NARROW OD ALLOWS PASSAGE THROUGH 1 1/2 FILL PIPE. CAT NO 5200 - RANGE -30 TO 120F IN 1 DIVISIONS COMPLETE WITH CASE CAT NO 5200R - RANGE -30 TO 120F IN 1 DIVISIONS - REFILL THERMOMETER ONLY CAT NO 5202 - RANGE -30 TO 180F IN 1 DIVISIONS COMPLETE WITH CASE CAT NO 5202R - RANGE -30 TO 180F IN 1 DIVISIONS - REFILL THERMOMETER ONLY GAUGING EQUIPMENT 1256TM 1256 1271C Page59 ACCESSORIES Page 61 Armor Cases Leatherette Cases Thermometer and Hydrometer Racks TEFLON ADJUSTABLE 10/18 ADAPTERS 10/18 STANDARD TAPER ADJUSTABLE TEFLON ADAPTER. ALLOWS VARI-IMMERSION THERMOMETERS TO BE USED IN 10/18 OR 10/30 FEMALE JOINTS. CAT NO. 4103 AVAILABLE TO FIT MOST THERMOMETERS LISTED IN THIS CATALOG. KESSLER ARMORS ARE FABRICATED FROM SEAMLESS BRASS TUBING AND ARE DOUBLE NICKEL PLATED. A RING IS FURNISHED AT THE TOP OF THE CASE FOR SUSPENSION. THE CUTOUT FRONT PORTION OF THE ARMOR ENABLES THE USER TO READ THE THERMOMETER SCALE WHILE IN THE CASE. 3250 For 6” thermometers 3252** For 12” thermometers 3251 For 15” thermometers 3253** For 6 1/4” thermometers 3254** 3256** 3257** 3258SS For 16” thermometers For 18” thermometers For 24” thermometers For 30” thermometers only available in stainless steel ACCESSORIES ARMOR CASES FOR GLASS THERMOMETERS ** ALSO AVAILABLE IN STAINLESS STEEL. ADD “SS” TO CATALOG NUMBER. LEATHERETTE STORAGE CASES WOODEN, LEATHERETTE COVERED CASE WITH VELVET LINED INTERIOR. 2 SAFETY SNAPS ON COVER. CALIBRATION CERTIFICATE MAY BE FOLDED AND STORED IN CASE WITH THERMOMETER. A ‘MUST’ FOR CERTIFIED OR EXPENSIVE THERMOMETERS TO PREVENT BREAKAGE IN STORAGE OR IN TRANSIT. CAT NO CAPACITY 3260 3262 3264 3265 3266 3267 3268 1 thermometer 1 thermometer 1 thermometer 1 thermometer 9 thermometers 9 hydrometers 10 hydrometers MAXIMUM LENGTH OF THERMOMETER 12.5” (317mm) 16.5” (420mm) 18.5” (470mm) 24.5” (620mm) 16” (406mm) 12” (305mm) 15” (381mm) PVC STORAGE CASES FOR THERMOMETERS AND HYDROMETERS CONSTRUCTED OF RUGGED APPLICATIONS. PVC PLASTIC, LINED WITH HEAVY CARPET-LIKE CUSHIONING TO PROVIDE EXCEPTIONAL DURABILITY AND PROTECTION FOR THE INSTRUMENT IN FIELD FRICTION-FIT CAP. CAT NO 3270 3272 3274 3276 8960 8962 CAPACITY MAXIMUM 1 thermometer 1 thermometer 1 thermometer 1 hydrometer 1 hydrometer 1 hydrometer 12” 16” 18” 24” 13” 15” LENGTH (305mm) (406mm) (457mm) (610mm) (330mm) (385mm) POLYPROPYLENE THERMOMETER AND HYDROMETER RACKS FRAGILE GLASS THERMOMETERS AND HYDROMETERS ARE PROTECTED AND HELD IN THE PREFERRED UPRIGHT POSITION BY PLACING THEM IN THESE RACKS. CAT NO 8990 8992 8998 TYPE Hydrometers, long form Hydrometers, short form Thermometers CAPACITY Holds 9” to 15” hydrometers Holds 6” to 9” hydrometers Holds 6” and longer thermometers THERMOMETER READING GLASS THERMOMETER READING LENS, SINGLE ELEMENT TYPE, APPROXIMATE MAGNIFICATION 4X, FOCAL LENGTH 50MM. WITH SPRING CLIP FOR ATTACHMENT DIRECTLY TO THERMOMETERS WITH OUTSIDE DIAMETER 6 TO 16MM. OBSERVATION TUBE HAS OPENING 5/32-INCH DIAMETER TO FACILITATE READING WITHOUT PARALLAX. CATALOG NO. 4300 Page 63 THERMOMETER CALIBRATION EQUIPMENT Page 65 Most laboratories are required to periodically reverify ALL their temperature measuring devices, from precision glass thermometers to bimetal dial thermometers to thermistor based electronics. The KESSLER TCB-900 offers the quality conscious laboratory the means to accurately and effectively compare these devices to an NIST Traceable Certified Thermometer, thus satisfying the mandates of good practice and the requirements of regulatory agencies. TEMPERATURE CALIBRATION SYSTEM SATISFIES THE REQUIREMENTS OF THE F.D.A. & E.P.A THE KESSLER TCB-900 THERMOMETER CALIBRATION BATH HAS BEEN DESIGNED TO PERMIT CALIBRATION AND VERIFICATION OF LIQUID-IN-GLASS THERMOMETERS, DIAL THERMOMETERS, DIGITAL THERMOMETERS AND MOST ANY TEMPERATURE INSTRUMENT THE WORKING DEPTH OF THE CONSTANT TEMPERATURE BACK IS 12”, WHICH WILL PERMIT MOST 15” TOTAL IMMERSION THERMOMETERS TO BE USED UNDER CORRECT CONDITIONS OF IMMERSION, AS WELL AS ACCOMMODATING ALL PARTIAL IMMERSION THERMOMETERS. REQUIRING THE USE OF A PRECISION TEMPERATURE COMPARATOR. THE TCB-900 HAS BEEN DESIGNED AND BUILT TO SATISFY THE REQUIREMENTS OF NIST SP 250-23 AND ASTM E-77. THE TCB-900 CONSISTS OF A CONSTANT TEMPERATURE BATH AND A SEPARATE, BUILT-IN DEWAR FLASK FOR COMPARISON OF CERTIFIED AND ‘WORKING’ THERMOMETERS. THE TCB-900 IS ENTIRELY SOLID CONTAINED, COMPACT AND LIGHTWEIGHT, REQUIRING LITTLE COUNTER SPACE. TEMPERATURES BELOW AMBIENT CAN BE ATTAINED BY CIRCULATING TAP WATER THROUGH THE BUILT IN COOLING COIL. IN THE EVENT YOUR LAB HAS REFRIGERATED RECIRCULATING EQUIPMENT, THE COOLANT CAN BE CIRCULATED THROUGH THE COIL, ALLOWING OPERATION DOWN TO APPROXIMATELY -30C, DEPENDING UPON THE CAPACITY OF YOUR EQUIPMENT. LABORATORY PRECISION The calibration bath holds temperatures to +/- 0.02C in the range of +15 to 200C. Adjustment is made by means of a dial, with a large digital readout. 201C in 0.2 divisions, 76mm Immersion, Simply dial in the desired temperature. Fine adjustment to standard thermometer is made by means of fine adjustment knob. 200C with protective storage case. TCB-900 Controlled Chamber 12” Ice Bath 10.5” CONTROLLER +/-0.02C Electronic solid state digital - thermometer sensor READOUT EASY, AUTOMATIC OPERATION 15C 24”length. Certified traceable to NBS at 0, 20, 40, 60, 80, 100, 120, 140, 160, 180 200C, MODEL MINIMUM TEMP MAXIMUM TEMP UNIFORMITY WORKING DEPTH LED Switchable Celsius or Fahrenheit HEATER OVERTEMP THERMOMETER READING GLASS ASTM E77 TEST METHOD “Calibration and Verification of Liquid in Glass Thermometers” COMPLETE INSTRUCTIONS 1000W CALIBRATION EQUIPMENT TCB-900 Safety control protects against overheating - screwdriver adjustable from rear of bath. DRAINS For both heated bath and ice bath SAFETY Overflow port STAINLESS STEEL Interior, steel exterior with corrosion resistant polyurethane finish. COOLING COIL VERSATILE The system includes an ice bath for performing ice points calibration. Main bath may be cooled below ambient by circulating tap water or refrigerated liquid through built in cooling loop. For operation at below ambient temperatures. MOTOR DIMENSIONS 1/15hp WEIGHT ELECTRICAL SHIPPING WEIGHT DIM 45lbs (dry) 17” 23”h x 18” x THIS PRODUCT, ALL COMPONENTS AND ACCESSORIES ARE MADE IN THE UNITED STATES OF AMERICA. 110v AC 60C 66lbs 21 x 24 x 29 in Accessories shipped separately SPECIFICATIONS SPECIFICATIONS TURNTABLE RACK holds six thermometers plus port for standard thermometer. CERTIFIED THERMOMETER range -1/ Page 67 HYDROMETERS Page 69 Popular in many applications due to small amount of product sample required to take a reading, these instruments are manufactured to strict ASTM specifications and to KESSLER’s own demanding quality control standards. ASTM HYDROMETERS - API - 6” LENGTH CAT NO ASTM 7500 7502 7504 7506 7508 7510 7512 7514 7516 7518 7520 7522 7524 7526 7528 21H 22H 23H 24H 25H 26H 27H 28H 29H 30H 31H 32H 33H 34H 35H API RANGE 0 to 6 5 to 11 10 to 16 15 to 21 20 to 26 25 to 31 30 to 36 35 to 41 40 to 46 45 to 51 50 to 56 55 to 61 60 to 66 65 to 71 70 to 76 DIV 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 CAT NO ASTM API RANGE DIV CAT NO API RANGE DIV 7530 7532 7534 7536 7539 7550 7552 7554 7556 7558 7560 7562 7564 7566 36H 37H 38H 39H ----------------------------------------- 75 to 81 80 to 86 85 to 91 90 to 96 89 to 101 -1 to 11 9 to 21 19 to 31 29 to 41 39 to 51 49 to 61 59 to 71 69 to 81 79 to 91 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 HYDROMETERS - API - 4” LENGTH ALLOW ACCURATE TESTING WITH AN EVEN SMALLER SAMPLE (4OZ) THAN ABOVE UNITS. CAT NO API RANGE 7500-4 7502-4 7504-4 7506-4 7508-4 7510-4 7512-4 7514-4 7516-4 7518-4 7520-4 7522-4 7524-4 7526-4 0 to 6 5 to 11 10 to 16 15 to 21 20 to 26 25 to 31 30 to 36 35 to 41 40 to 46 45 to 51 50 to 56 55 to 61 60 to 66 65 to 71 DIV 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 7530-4 7532-4 7534-4 7536-4 7539-4 7550-4 7552-4 7554-4 7556-4 7558-4 7560-4 7562-4 7564-4 7566-4 75 to 81 80 to 86 85 to 91 90 to 96 89 to 101 -1 to 11 9 to 21 19 to 31 29 to 41 39 to 51 49 to 61 59 to 71 69 to 81 79 to 91 ------------------------------------- 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 SHORT FORM THERMO-HYDROMETERS 7502 APPROXIMATELY 190MM (7 1/2”) LENGTH. THERMOMETERS IN BODY. CAT NO ASTM 7600 7602 7604 7606 7608 7610 7612 7614 7616 7618 ASTM LPG ----------------------------------------- API RANGE -1 to 11 9 to 21 19 to 31 29 to 41 39 to 51 49 to 61 59 to 71 69 to 81 79 to91 89 to 101 (LIQUEFIED PETROLEUM GAS) DIV 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 TEMP RANGE 0 0 0 0 0 0 0 0 0 0 to to to to to to to to to to 130OF 130OF 130OF 130OF 130OF 130OF 130OF 130OF 130OF 130OF DIV LENGTH DIV LENGTH 2 2 2 2 2 2 2 2 2 2 190mm 190mm 190mm 190mm 190mm 190mm 190mm 190mm 190mm 190mm HYDROMETER FOR TESTING OF LPG IN ACCORDANCE WITH ASTM METHODS. CAT NO ASTM 7830 8814 310H 101H SCALE RANGE 500 to 650 Kg/M3 -500 to -650 SG DIV 1.0 .001 TEMP RANGE 0 to 35OC 30 to 90OC 0.5 1.0 355mm 355mm 7608 PETROLEUM HYDROMETERS API SCALE FOR PETROLEUM PRODUCTS MANUFACTURED STRICTLY IN ACCORDANCE WITH ALL APPLICABLE ASTM SPECIFICATIONS, THESE UNITS HAVE BECOME THE INDUSTRY STANDARD FOR CLOSE ACCURATE READINGS. ALL INSTRUMENTS IN THIS SERIES ARE SUITABLE FOR CERTIFICATION AND AS SUCH SERVE AS PRIMARY REFERENCE STANDARDS IN MANY GOVERNMENTAL AND PRIVATE LABORATORIES. API SCALE FOR PETROLEUM PRODUCTS WITHOUT THERMOMETER CAT NO 7000 7002 7004 7006 7008 7010 7012 7014 7016 7018 7020 ASTM 1H 2H 3H 4H 5H 6H 7H 8H 9H 10H API RANGE -1 to 11 9 to 21 19 to 31 29 to 41 39 to 51 49 to 61 59 to 71 69 to 81 79 to 91 89 to 101 10 to 100 DIV 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 1.0 LENGTH 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm ASTM API THERMO-HYDROMETERS 380MM LENGTH - THERMOMETER IN BODY. CAT NO ASTM* API RANGE DIV TEMP RANGE DIV LENGTH 7050 51HH -1 to 11 0.1 60 to 220OF 2 380mm 7050L 51HL -1 to 11 0.1 0 to 150OF 2 380mm 7052 52HH 9 to 21 0.1 60 to 220OF 2 380mm 7052L 52HL 9 to 21 0.1 0 to 150OF 2 380mm 7054 53HM 19 to 31 0.1 30 to 180OF 2 380mm 7054L 53HL 19 to 31 0.1 0 to 150OF 2 380mm O 7056 54HM 29 to 41 0.1 30 to 180 F 2 380mm O 7056L 54HL 29 to 41 0.1 0 to 150 F 2 380mm O 7058 55HL 39 to 51 0.1 0 to 150 F 2 380mm O 7060 56HL 49 to 61 0.1 0 to 150 F 2 380mm 7062 57HL 59 to 71 0.1 0 to 150OF 2 380mm 7064 58HL 69 to 81 0.1 0 to 150OF 2 380mm 7066 59HL 79 to 91 0.1 0 to 150OF 2 380mm 7068 60HL 89 to 101 0.1 0 to 150OF 2 380mm 7076 -----10 to 30 0.2 0 to 150OF 2 380mm O 7078 -----20 to 40 0.2 0 to 150 F 2 380mm O 7080 -----30 to 50 0.2 0 to 150 F 2 380mm O 7006 7082 -----40 to 60 0.2 0 to 150 F 2 380mm O 7084 -----50 to 70 0.2 0 to 150 F 2 380mm O 7088 -----70 to 90 0.2 0 to 150 F 2 380mm 7092 -----29 to 45 0.1 0 to 150OF 2 380mm 7094 -----33 to 48 0.1 0 to 150OF 2 380mm 7096 -----19 to 45 0.1 0 to 150OF 2 380mm 7098 -----30 to 90 0.5 0 to 150OF 2 380mm * ASTM DESIGNATIONS FOR TEMPERATURE RANGES INDICATED: H (HIGH) 60/220F, M (MEDIUM) 30/180, L (LOW) 0/150F ANY OF THESE RANGES CAN BE FURNISHED WITH THE HYDROMETERS LISTED ABOVE UPON REQUEST. ASTM API THERMO-HYDROMETERS WITH THERMOMETER IN STEM USEFUL FOR TESTING OF HEAVY OIL WHERE DARK COLOR PREVENTS READING THE THERMOMETER IN THE BODY OF A CONVENTIONAL THERMOHYDROMETER. CAT NO ASTM* 7100 7102 7104 7106 7108 7110 7112 7114 71H 72H 73H 74H ----------------- API RANGE -1 to 11 9 to 21 19 to 31 29 to 41 39 to 51 49 to 61 59 to 71 69 to 81 DIV 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 TEMP RANGE 30 30 30 30 30 30 30 30 to to to to to to to to 220OF 220OF 220OF 220OF 220OF 220OF 220OF 220OF DIV 2 2 2 2 2 2 2 2 LENGTH 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 7056L 7056 Pageb71 Developed jointly with ISO (International Standards organization) standards to serve those users involved in their international transport of petroleum products, this series has been adopted by ASTM and their use sanctioned as the metric standard for petroleum hydrometers. All comply with the demanding specifications set forth in ASTM E-100-91 Graduated in Kg/M3 (Kilograms per cubic meter) @ 15 Degrees C for petroleum products. ASTM METRIC DENSITY HYDROMETERS CAT NO 7702 7704 7706 7708 7710 7712 7714 7716 7718 7720 ASTM 311H 312H 313H 314H 315H 316H 317H 318H 319H 320H DENSITY RANGE 600 to 650 650 to 700 700 to 750 750 to 800 800 to 850 850 to 900 900 to 950 950 to 1000 1000 to 1050 1050 to 1100 DIV 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 LENGTH 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm 330mm ASTM METRIC THERMOHYDROMETERS THERMOMETER IN BODY. CAT NO ASTM* 7802 7804 7806 7806M 7808 7808M 7810 7810M 7812L 7812 7814L 7814 7816L 7816 7818 7818L 7820 7820L 300HL 301HL 302HL 302HM 303HL 303HM 304HL 304HM 305HL 305HM 306HL 306HM 307HL 307HH 308HH 308HL 309HH 309HL DENSITY RANGE 600 to 650 650 to 700 700 to 750 700 to 750 750 to 800 750 to 800 800 to 850 800 to 850 850 to 900 850 to 900 900 to 950 900 to 950 950 to 1000 950 to 1000 1000 to 1050 1000 to 1050 1050 to 1100 1050 to 110 DIV 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 TEMP RANGE -20 to 65OC -20 to 65OC -20 to 65OC 0 to 85OC -20 to 65OC 0 to 85OC -20 to 65OC 0 to 85OC -20 to 65OC 0 to 85OC -20 to 65OC 0 to 85OC -20 to 65OC +20 to 105OC +20 to 105OC -20 to 65OC +20 to 105OC -20 to 65OC DIV 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LENGTH 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 380mm 7706 ASTM SPECIFIC GRAVITY SERIES SPECIFIC GRAVITY HYDROMETERS 60/60F AS SPECIFIED IN ASTM E-100-91. (ALL SUITABLE FOR CERTIFICATION). CAT NO 8001 8000 8002 8003 8004 8005 8006 8008 8010 8012 8014 8016 8020 8030 8032 8034 8036 ASTM 82H 83H 84H 85H 86H 87H 88H 89H 90H 98H 102H 103H 104H 105H GRAVITY RANGE .600 to .650 .650 to .700 .700 to .750 .650 to .750 .750 to .800 .750 to .850 .800 to .850 .850 to .900 .900 to .950 .950 to 1.000 1.000 to 1.050 1.050 to 1.100 .950 to 1.000 .650 to .700 .700 to .750 .750 to .800 .800 to .850 DIV 0.0005 0.0005 0.0005 --------0.0005 --------0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.001 0.001 0.001 0.001 LENGTH 330mm 330mm 330mm ---------330mm ---------330mm 330mm 330mm 330mm 330mm 330mm 330mm 260mm 260mm 260mm 260mm 8036 HYDROMETERS ASTM SPECIFIC GRAVITY SERIES (CONTINUED) SPECIFIC GRAVITY HYDROMETERS 60/60F AS SPECIFIED IN ASTM E-100-91. (ALL SUITABLE FOR CERTIFICATION). CAT NO 8038 8040 8042 8200 8202 8204 8206 8208 8210 8212 8214 8216 8218 8230 8232 8234 8236 8238 8240 8242 8244 8246 8248 8250 8252 8254 8256 8258 8260 8262 8264 8266 8266 ASTM 106H 107H 108H 111H 112H 113H 114H 115H 116H 117H 118H 119H 120H 125H 126H 127H 128H 129H 130H 131H 132H 133H 134H 135H 136H 137H 138H 139H 140H 141H 142H 143H 144H GRAVITY RANGE .850 to .900 .900 to .950 .950 to 1.000 1.000 to 1.050 1.050 to 1.100 1.100 to 1.150 1.150 to 1.200 1.200 to 1.250 1.250 to 1.300 1.300 to 1.350 1.350 to 1.400 1.400 to 1.450 1.450 to 1.500 1.000 to 1.050 1.050 to 1.100 1.100 to 1.150 1.150 to 1.200 1.200 to 1.250 1.250 to 1.300 1.300 to 1.350 1.350 to 1.400 1.400 to 1.450 1.450 to 1.500 1.500 to 1.550 1.550 to 1.600 1.600 to 1.650 1.650 to 1.700 1.700 to 1.750 1.750 to 1.800 1.800 to 1.850 1.850 to 1.900 1.900 to 1.950 1.950 to 2.000 DIV 0.001 0.001 0.001 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 LENGTH 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 260mm 8230 8200 SPECIFIC GRAVITY HYDROMETERS SEQUENTIAL RANGES (60/60F) 6” HYDROMETERS IN - .070 SG RANGES CAT NO 8140 8141 8142 8143 8144 8145 8146 8286 8287 8288 8289 8290 GRAVITY RANGE .590 to .660 .650 to .710 .700 to .770 .760 to .830 .820 to .890 .880 to .950 .940 to 1.010 1.000 to 1.070 1.060 to 1.130 1.120 to 1.190 1.180 to 1.250 1.240 to 1.310 DIV 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 CAT NO GRAVITY RANGE CAT NO GRAVITY RANGE 8291 8292 8293 8294 8295 8296 8297 8298 8299 8301 8303 1.300 1.360 1.420 1.480 1.540 1.600 1.660 1.720 1.780 1.840 1.910 to to to to to to to to to to to 1.370 1.430 1.490 1.550 1.610 1.670 1.730 1.790 1.850 1.920 1.980 DIV 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 6” HYDROMETERS - .100 SG RANGES CAT NO 8100 8102 8104 8106 8300 8302 8304 GRAVITY RANGE .600 to .710 .700 to .810 .800 to .910 .900 to 1.010 1.000 to 1.110 1.100 to 1.210 1.200 to 1.310 DIV 0.002 0.002 0.002 0.002 0.002 0.002 0.002 8306 8308 8310 8312 8314 8316 8318 1.300 1.400 1.500 1.600 1.700 1.800 1.900 to to to to to to to 1.410 1.510 1.610 1.710 1.810 1.910 2.010 DIV 0.002 0.002 0.002 0.002 0.002 0.002 0.002 8144 8286 Page 73 6” HYDROMETERS - .200 SG RANGES CAT NO 8320 8322 8324 GRAVITY RANGE 1.000 to 1.220 1.200 to 1.420 1.400 to 1.620 DIV CAT NO 0.005 0.005 0.005 8326 8328 8321 GRAVITY RANGE 1.600 to 1.820 1.800 to 2.000 1.100 to 1.300 LONG SPECIFIC GRAVITY HYDROMETERS SEQUENTIAL RANGES DIV 0.005 0.005 0.005 (60/60F) 13” HYDROMETERS - .070 SG RANGES CAT NO 8147 8148 8149 8150 8151 8152 8153 8270 8271 8272 8273 8274 GRAVITY RANGE .600 to .660 .650 to .710 .700 to .770 .760 to .830 .820 to .890 .880 to .950 .940 to 1.010 1.000 to 1.070 1.060 to 1.130 1.120 to 1.190 1.180 to 1.250 1.240 to 1.310 DIV 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 CAT NO GRAVITY RANGE CAT NO GRAVITY RANGE CAT NO GRAVITY RANGE 8275 8276 8277 8278 8279 8280 8281 8282 8283 8284 8285 1.300 1.360 1.420 1.480 1.540 1.600 1.660 1.720 1.780 1.840 1.910 to to to to to to to to to to to 1.370 1.430 1.490 1.550 1.610 1.670 1.730 1.790 1.850 1.920 2.010 DIV 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 12” HYDROMETERS - .100 SG RANGES CAT NO 8130 8132 8134 8136 8350 8352 8354 GRAVITY RANGE .600 to .710 .700 to .810 .800 to .910 .900 to 1.010 1.000 to 1.110 1.100 to 1.210 1.200 to 1.310 DIV 0.001 0.001 0.001 0.001 0.001 0.001 0.001 8356 8358 8360 8362 8364 8364 8366 1.300 1.400 1.500 1.600 1.700 1.800 1.900 to to to to to to to 1.410 1.510 1.610 1.710 1.810 1.910 2.010 DIV 0.001 0.001 0.001 0.001 0.001 0.001 0.001 12” HYDROMETERS - .200 SG RANGES CAT NO 8369 8370 8371 8372 8373 8374 8376 GRAVITY RANGE .900 to 1.100 1.000 to 1.220 1.100 to 1.300 1.200 to 1.300 1.300 to 1.500 1.400 to 1.620 1.600 to 1.820 DIV 0.002 0.002 0.002 0.002 0.002 0.002 0.002 12” HYDROMETERS - SPINDLE (VERY 8378 8382 8384 8386 8388 8386 LONG) 1.800 2.000 2.200 2.400 2.600 2.800 to to to to to to 2.010 2.200 2.400 2.600 2.800 3.000 DIV 0.002 0.002 0.002 0.002 0.002 0.002 RANGES A SPINDLE HYDROMETER ALLOWS THE USER TO EASILY ASCERTAIN THE GRAVITY OF AN UNKNOWN SOLUTION, SO THAT A MORE PRECISE HYDROMETER CAN BE USED FOR THE ACTUAL MEASUREMENT. CAT NO 8379 8380 8392 GRAVITY RANGE 1.000 to 1.600 1.000 to 2.000 2.000 to 3.000 DIV 0.005 0.010 .010 CAT NO 8396 8398 GRAVITY RANGE .650 to 1.000 .700 to 1.000 8382 DIV 0.1 0.005 8369 HYDROMETERS DUAL SCALE - SPECIFIC GRAVITY & BAUME SPECIFIC GRAVITY, PERHAPS THE MOST COMMONLY USED SCIENTIFIC SCALE, IS EXPRESSED AS THE RATIO OF THE MASS (WEIGHT) OF A GIVEN VOLUME OF LIQUID TO THE IDENTICAL VOLUME OF WATER, BOTH LIQUIDS USUALLY AT AN EQUAL TEMPERATURE, MOST OFTEN 60F (15.56C). BAUME IS MOST OFTEN USED IN THE CHEMICAL INDUSTRY. THE BAUME SCALE IS EXPRESSED AS ‘LIGHT’ FOR LIQUIDS WITH A GRAVITY BELOW 1.000 SG, OR ‘HEAVY’ FOR LIQUIDS WITH A GRAVITY HEAVIER THAN 1.000 SG. IN THE ABSENCE OF THE DESIGNATION ‘LIGHT’ OR ‘HEAVY’, IT IS ASSUMED TO BE HEAVY. BAUME LIGHT (BL) IS DEFINED AS BL = (140/SG) - 130. BAUME HEAVY (BH) IS DEFINED AS BH = 145 - (145/SG). SPECIFIC GRAVITY & BAUME LIGHT CAT NO 8799.6 8799.8 8800 8801 8805 8804 8802 8802.5 8803 SPECIFIC GRAVITY .600 to 1.000 .650 to 1.000 .700 to .810 .700 to .860 .700 to 1.000 .800 to 1.000 .800 to .910 .840 to 1.000 .900 to 1.010 BAUME LIGHT DIV, SG DIV, BAUME LENGTH BAUME HEAVY DIV, SG DIV, BAUME LENGTH 0 to 26 24 to 43 42 to 55 54 to 65 64 to 73 0 to 45 0 to 55 40 to 72 0 to 70 .002 .002 .002 .002 .002 .005 .010 .010 .010 0.2 0.2 0.2 0.2 0.2 0.5 1.0 0.5 1.0 12” 12” 12” 12” 12” 12” 12” 12” 12” 100 to 10 85 to 10 70 to 45 70 to 35 70 to 10 45 to 10 45 to 25 37 to 10 25 to 10 .005 .005 .001 .002 .005 .005 .001 .002 .001 1.0 1.0 0.5 0.5 1.0 1.0 0.2 0.5 1.0 12” 12” 12” 12” 12” 12” 12” 12” 12” SPECIFIC GRAVITY & BAUME HEAVY CAT NO 8806-6 8807-6 8808-6 8809-6 8810-6 8810.5-6 8812-6 8813-6 8806 8807 8808 8809 8810 8810.5 8811 8812 8813 SPECIFIC GRAVITY 1.000 1.200 1.400 1.600 1.800 1.000 1.400 1.000 to to to to to to to to 1.220 1.420 1.620 1.820 2.020 1.400 2.000 2.000 1.000 1.200 1.400 1.600 1.800 1.000 1.000 1.400 1.000 to to to to to to to to to 1.220 1.420 1.620 1.820 2.020 1.450 1.600 2.000 2.000 0 to 26 24 to 43 42 to 55 54 to 65 64 to 73 0 to 41 40 to 72 0 to 70 .005 .005 .005 .005 .005 .010 .010 .020 0.5 0.5 0.5 0.5 0.5 1.0 1.0 1.0 6” 6” 6” 6” 6” 6” 6” 6” SPINDLE HYDROMETER (VERY LONG) RANGE A SPINDLE HYDROMETER ALLOWS THE USER TO EASILY ASCERTAIN THE GRAVITY MORE PRECISE HYDROMETER CAN BE USED FOR THE ACTUAL MEASUREMENT. CAT NO 8815 SPECIFIC GRAVITY .700 to 2.000 OF AN UNKNOWN SOLUTION, SO THAT A BAUME HEAVY 70 Lt to 70 Hvy DIV, SG .010 DIV, BAUME 1.0 LENGTH 18” 8806-6 SPINDLE THERMOHYDROMETERS (VERY LONG) RANGES A SPINDLE HYDROMETER ALLOWS THE USER TO EASILY ASCERTAIN THE GRAVITY MORE PRECISE HYDROMETER CAN BE USED FOR THE ACTUAL MEASUREMENT. CAT NO 8819 8820 8821 8822 SPECIFIC GRAVITY .600 to 1.000 1.000 to 2.000 1.000 to 2.000 .650 to 1.000 OF AN UNKNOWN SOLUTION, SO THAT A BAUME HEAVY 85 Lt to 10 Lt 0 to 72 DIV, SG .005 .010 .010 .005 DIV, BAUME 0.5 1.0 TEMP RANGE 0 0 0 0 to to to to 120OF 120OF 120OF 120OF Page 75 BAUME HYDROMETERS (MODULUS 145, TEMPERATURE 60F) 12” BAUME HEAVY HYDROMETERS CAT NO 8500 8501 8502 8503 8506 8508 8508.5 8509 8515 8510 8516 8511 RANGE, BAUME 0 to 50 0 to 70 0 to 25 0 to 35 -5 to +5 -1 to 11 5 to 15 9 to 21 15 to 25 19 to 31 25 to 35 29 to 41 DIV 0.5 1.0 0.5 0.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 CAT NO RANGE, BAUME 33 to 37 35 to 45 35 to 70 39 to 51 45 to 55 49 to 61 55 to 65 59 to 71 64 to 66.5 69 to 81 79 to 91 89 to 101 0.05 0.1 0.5 0.1 0.1 0.1 0.1 0.1 0.05 0.1 0.1 0.1 CAT NO RANGE, BAUME DIV CAT NO RANGE, BAUME DIV 8511.5 8517 8517.5 8512 8518 8513 8519 8514 8514.5 8520 8522 8524 DIV 6” BAUME HEAVY HYDROMETERS CAT NO 8550 8551 8552 8557 8563 8564 RANGE, BAUME 0 to 20 20 to 40 40 to 60 0 to 70 -1 to 11 9 to 21 DIV 0.5 0.5 0.5 1.0 0.2 0.2 8565 8566 8567 8568 8569 19 29 39 49 59 to to to to to 31 41 51 61 71 0.2 0.2 0.2 0.2 0.2 12” BAUME LIGHT HYDROMETERS CAT NO 8508LT 8509LT 8510LT 8511LT RANGE, BAUME -1 to 11 9 to 21 19 to 31 29 to 41 DIV 0.1 0.1 0.1 0.1 8512LT 8513LT 8514LT 39 to 51 49 to 61 59 to 71 0.1 0.1 0.1 TWADDLE SCALE HYDROMETERS CAT NO 8570 8571 8572 8573 8574 8575 RANGE DIV 0 to 26 24 to 50 48 to 74 70 to 104 102 to 136 134 to 160 LENGTH 0.5 0.5 0.5 0.5 0.5 0.5 9” 9” 9” 9” 9” 9” ASTM SOIL HYDROMETERS CAT NO ASTM GRAVITY RANGE CAT NO ASTM RANGE, GRMS/LITER 8650 8652 151H 152H .995 to 1.038 -5 to +60 DIV LENGTH DIV LENGTH 0.001 1 g/l 8509 280mm 280mm BRIX HYDROMETERS PER CENT SUGAR IN AQUEOUS SOLUTION @20C LENGTH: 275MM TO 330MM. CAT NO 8698 8700 8698.2 8698.4 8698.8 RANGE -5 to +5 -1 to 11 0 to 30 0 to 6 6 to 12 DIV 0.1 0.1 0.5 0.1 0.1 CAT NO 8706.8 8708 8708.2 8708.4 8710 RANGE 36 39 42 48 49 to to to to to 42 51 48 54 61 DIV 0.1 0.1 0.1 0.1 0.1 8504 HYDROMETERS BRIX HYDROMETERS (CONTINUED) PER CENT SUGAR IN AQUEOUS SOLUTION @20C LENGTH: 275MM TO 330MM. CAT NO 8702 8702.2 8702.4 8704 8704.4 8706 8706.2 8706.4 8706.6 RANGE 9 to 21 12 to 18 15 to 25 19 to 31 25 to 35 29 to 41 30 to 36 30 to 60 35 to 45 DIV CAT NO 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.5 0.1 RANGE 8710.2 8710.4 8712 8712.2 8712.4 8712.6 8714 8716 53 54 59 60 60 66 69 79 to to to to to to to to DIV 58 60 71 66 90 72 81 91 0.1 0.1 0.1 0.1 0.5 0.1 0.1 0.1 BRIX THERMOHYDROMETERS PER CENT SUGAR IN AQUEOUS SOLUTION @20C LENGTH; 305MM TO 386MM. CAT NO 8748 8750 8748.2 8748.4 8748.6 8752 8752.2 8752.4 8752.6 8754 8754.2 8754.4 8754.6 8756 8756.2 8756.4 8758 8760 8762 8762.2 8764 8766 BRIX RANGE -5 to +5 -1 to 11 0 to 30 0 to 6 5 to 11 9 to 21 10 to 16 15 to 21 -15 to 25 19 to 31 20 to 26 25 to 31 25 to 35 29 to 41 30 to 45 30 to 60 39 to 51 49 to 61 59 to 71 60 to 90 69 to 81 79 to 91 DIV 0.1 0.1 0.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.5 0.1 0.1 0.1 0.5 0.1 0.1 LENGTH TEMP RANGE LENGTH TEMP RANGE 330mm 330mm 305mm 330mm 330mm 365mm 385mm 330mm 365mm 365mm 385mm 385mm 365mm 365mm 380mm 305mm 365mm 365mm 365mm 305mm 365mm 380mm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 to to to to to to to to to to to to to to to to to to to to to to 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC 50OC BALLING SCALE THERMOHYDROMETERS FOR ALCOHOL TESTING. STANDARDIZED @68F (20C) CAT NO 8770 8772 BALLING RANGE 0 to 32 8 to 25 DIV 0.5 0.5 385mm 385mm 30 to 120OF 30 to 120OF PROOF SCALE HYDROMETERS FOR ALCOHOL TESTING. MEET NBS SPECIFICATIONS. STANDARDIZED @60/60F LENGTH 12” PROOF = % ALCOHOL BY VOLUME X 2. CAT NO 8843.5 8843.6 8843.7 8843.8 8843.9 8844 8845 8846 8847 8848 8850 PROOF RANGE 0 to 20 20 to 40 40 to 60 60 to 80 80 to 100 0 to 100 80 to 120 100 to 140 130 to 170 160 to 200 185 to 206 DIV 0.2 0.2 0.2 0.2 0.2 1.0 0.5 0.5 0.5 0.5 0.2 8752 US CUSTOMS HOUSE HYDROMETERS DUAL SCALE - PROOF & TRALLES. (TRALLES = % ALCOHOL BY VOLUME) HYDROMETER CAT NO 8843 8844 RANGE PROOF 0 to 200 DIV 2.0 RANGE TRALLES 0 to 100 DIV 2.0 LENGTH 12” Page 77 THERMOHYDROMETER WITH INTERNAL THERMOMETER, RANGE 0/120F CAT NO 8860 RANGE PROOF 0 to 200 DIV RANGE TRALLES DIV LENGTH 2.0 DIV 0 to 100 2.0 LENGTH 13” TRALLES HYDROMETER TRALLES = % ALCOHOL BY VOLUME @ 60F Not for Wine CAT NO 8780 8782 8784 8786 8788 8790 8792 TRALLES RANGE 0 to 50% 0 to 100% & Proof 0 to 5% 5 to 10% 10 to 15% 15 to 20% 20 to 25% 0.5% 1.0% 0.1% 0.1% 0.1% 0.1% 0.1% 12” 12” 9” 9” 9” 9” 9” POUNDS PER U.S. GALLON USEFUL IN DETERMINING THE ACTUAL WEIGHT OF A KNOWN VOLUME OF FUEL. USED PRINCIPALLY IN AVIATION LOADING APPLICATIONS. CAT NO 8881 8882 8883 8884 8885 RANGE, LBS./U.S. GAL 5.5 5.4 6.0 6.0 6.5 to to to to to 7.5 6.3 7.1 6.6 7.1 DIV .02 .01 .01 .01 .01 LENGTH 12” 12 1/2” 12 1/2” 12 1/2” 12 1/2” TYPE OF FUEL Full Range Gasoline JP-4 & Kerosene JP-4 Kerosene JET FUEL TESTING KIT THERMOHYDROMETER, API SCALE, RANGE 40/75 API, TEMP RANGE 0/130F, LENGTH 190MM FOR USE IN SYRINGE KIT. SCALE IS COLOR CODED AS FOLLOWS: FROM 40 TO 50 API - WHITE - MARKED KEROSENE FROM 50 TO 65 API - YELLOW - UNMARKED FROM 65 TO 75 API - GREEN - MARKED AVGAS Cat No 700 - Thermohydrometer with syringe kit consisting of rubber bulb, glass cylinder, and BUNAN pickup tube, Cat No 700-1 - Thermohydrometer only Cat No 700-2 - Syringe kit as described above, without hydrometer. SALINITY HYDROMETERS EXTREMELY SENSITIVE HYDROMETERS FOR DETERMINATION OF SPECIFIC GRAVITY. CAT NO 8900 8902 8904 RANGE DIV 1.000 to 1.011 1.010 to 1.021 1.020 to 1.031 .0002 .0002 .0002 LENGTH 9” 9” 9” 8843 SALT HYDROMETERS PERCENT SATURATION - NACL IN WATER @ 60F CAT NO 8920 8922 8924 8926 8928 RANGE DIV 0 to 15% 0 to 40% 40 to 70% 70 to 100% 0 to 100% .2% .5% .5% .5% 1.0% LENGTH 12” 13” 12” 12” 12” PERCENT NACL BY WEIGHT @ 60F CAT NO 8940 8942 RANGE 0 to 26.5% 0 to 26.5% DIV 0.5% 0.5% (20/120F) LENGTH 12” 12” PERCENT SATURATION CACL IN WATER @ 60F CAT NO 8945 RANGE 0 to 120 DIV 1.0 LENGTH 12” 8928 HYDROMETERS PEROXIDE HYDROMETER IN PLASTIC GRADUATED CYLINDER. PER CENT HYDROGEN PEROXIDE IN WATER @70F CAT NO 8950 RANGE 0 to 100 DIV LENGTH DIV LENGTH 2.0% 6” MILK HYDROMETER CAT NO 8400 8402 8404 8406 8408 8410 RANGE 14 to 42 14 to 42 0 to 120 29 to 35 24 to 37 0 to 120 1 1 1 0.2 .01 1 10.5” 12.5” 12” 6.5” 12” 12” TYPE Quevennes Quevennes - w/-10 to 40C thermometer in stem Spence Lactometer Stone Lactometer Lactometer Spence Lactometer - w/0 to 120F thermometer HYDROMETER JARS HYDROMETER JARS OF RUGGED BOROSILICATE GLASS CONSTRUCTION, FREE FROM MECHANICAL DEFECTS AND INTERNAL STAIN. HAVE BEEN CHOSEN TO SECURE MAXIMUM STABILITY. THE LISTED DIMENSIONS ARE APPROXIMATE. CAT NO F1038200 F1038300 F1038375 F1050375 F1063460 SIZE, 38 38 38 50 63 x x x x x MM 200 300 375 375 460 THE FOOT DIAMETERS WITH POUR OUT SPOUT. SIZE, INCHES 1.5 x 8 1.5 x 12 1.5 x 15 2 x 15 2.5 x 18 GRADUATED CYLINDERS CALIBRATED ON THE BASIS OF THE TRUE METRIC LITER. DOUBLE SCALES. CAT NO F450050 F450100 F450250 F450500 F4501000 CAPACITY, 50 100 250 500 1000 ML F450050 8402 SUGGESTIONS TO ASSURE ACCURATE HYDROMETER READINGS. 1 - BE SURE HYDROMETER IS CLEAN AND DRY. 2 - SMOOTH CLEAR CYLINDER OR JAR FOR LIQUID TESTED; SHOULD BE DRY OR WELL RINSED WITH PORTION OF SAMPLE. 3 - SAMPLE MUST BE THOROUGHLY MIXED BEFORE TESTING. PREFERABLY BY A STIRRER WHICH REACHES BOTTOM OF SAMPLE CONTAINER. 4 - IMMERSE HYDROMETER SLOWLY IN LIQUID TO A POINT BELOW WHICH IT NATURALLY SINKS (NOT OVER 1/8”) 5 - DO NOT MAKE READING TILL THE HYDROMETER AND LIQUID ARE AT REST AND FREE FROM AIR BUBBLES. 6 - THE TEMPERATURES OF THE HYDROMETER AND LIQUID TESTED SHOULD BE EQUAL. 7 - MORE ACCURATE READINGS RESULT WHEN THE TEMPERATURE OF THE LIQUID APPROACHES THAT OF THE SURROUNDING ATMOSPHERE. WHEN DIFFERENCES OF TEMPERATURE ARE NECESSARY AND VARY FROM THE STANDARD, THE READING CAN BE APPROXIMATED BY USE OF CORRECTED TABLES. 8 - SURFACE TENSION OF THE LIQUID AFFECTS HYDROMETER OBSERVATIONS. THE LIQUID FOR WHICH A HYDROMETER IS INTENDED MUST BE SPECIFIED SINCE IT WILL INDICATE DIFFERENTLY IN TWO LIQUIDS HAVING THE SAME DENSITY BUT DIFFERENT 9 - HYDROMETERS OF EQUIVALENT DIMENSIONS MAY BE COMPARED WITH EACH OTHER EVEN IF THE LIQUID USED DIFFERS IN SURFACE TENSION FROM THE SPECIFIED LIQUID, BUT COMPARISONS OF DISSIMILAR INSTRUMENTS, IN SUCH A LIQUID, MUST BE CORRECTED FOR THE EFFECT OF SURFACE TENSION. 10 - TO AVOID ERRORS DUE TO SPONTANEOUS CHANGES IN SURFACE TENSION SKIMMING AND FORMATION OF SURFACE FILMS OF IMPURITIES FROM APPARATUS, LIQUID OR AIR, OVERFLOW THE CYLINDER IMMEDIATELY BEFORE TAKING THE READING. 11 - TO READ THE HYDROMETER BRING THE EYE, PREFERABLY FROM BELOW, TO THE LEVEL OF THE PLANE SURFACE OF THE LIQUID. READ THE POINT WHERE THE SCALE IS CUT BY THE SURFACE LINE. 12 - ERRORS OF PARALLAX WHEN READING THERMOMETER SCALE CAN BE AVOIDED BY ALIGNING THE NEAR END OF THE MERCURY COLUMN. THE PORTIONS ON EITHER SIDE OF THE STEM AND THOSE SEEN THROUGH THE CAPILLARY SO THEY APPEAR TO BE A STRAIGHT LINE. WHEN THE EYE IS IN THIS POSITION THE LINE OF SIGHT IS NORMAL TO THE STEM. * CONDENSED LARGELY FROM BUREAU OF STANDARDS CIRCULAR NO. 16. SURFACE TENSIONS. Page 79 BIMETAL THERMOMETERS Page 81 LABORATORY AND GENERAL TEST THERMOMETERS 1 3/4” AND 2” DIAL SIZE FEATURES • • • • • • • • • • • • Models GT-100R & LT-225R easy to recalibrate using wrench on hex surface on back of dial. Type 304 stainless steel in stem and case. Head diameter: GT-100R 1.75”; LT-225R 2”. Stem diameter: .150 Standard; GT-100R available .142, LT-225R Series available .187. Corrosion resistant to most chemicals. Rustproof - Dustproof - Leakproof - Hermetically sealed. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer. Adjustable clamp for tank and tray mounting. Guaranteed accurate within 1/2 of 1% around entire dial range. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Durable - non-fragile - safe to handle. o o Over range protection is 50% up to 500 F and 10% over 500 F. STANDARD DIALo RANGES FAHRENHEIT /DIV CENTIGRADE o o o -100 to 100 2 -50 to 100 o o -40 to 160 2 o o o 0 to 140 2 -10 to 110 o o o 0 to 180 2 **0 to 50 o o o 0 to 220 2 0 to 100 o o o *25 to 125 1 0 to 150 o o 20 to 240 2 o o o 50 to 250 2 0 to 250 o o o 50 to 300 2 0 to 300 o o o 50 to 400 5 100 to 400 o o 50 to 500 5 o o 150 to 750 10 o o *200 to 1000 10 O * NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F. Model LT-225R DIV o 1 o 1 o 1/2 o 1 o 1 o 2 o 5 o 5 Model GT-100R 1 3/4” AND 2” SIZE FEATURES • • • • • • • • • • • • • Model LN-250R easy to recalibrate by loosening a socket head screw above hex connecting nut. Model numbered GT-200 supplied without recalibration device. Connection Nut: 1/4” N.P.T. standard, other sizes available at extra charge. Type 304 stainless steel in stem and case. All welded construction. Head diameter: GT-200 1 3/4”; LN-250 Series 2”. Rustproof - Dustproof - Leakproof - Hermetically sealed. Stem diameter: LN-250R 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”, including threads. Available in stem lengths up to 72”. GT-200: Standard stem length 2 1/2”, 4”, 6”. Available 8”, 12”, 18”. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer Guaranteed accurate with 1% around entire dial range. o o over-range protection 50% up to 500 F, 10% above 500 F. STANDARD DIALo RANGES FAHRENHEIT /DIV CENTIGRADE o o o -100 to 100 2 -50 to 100 o o o -40 to 160 2 -50 to 25 o o o 0 to 140 2 -10 to 110 o o o 0 to 180 2 **0 to 50 o o o 0 to 220 2 0 to 100 o o o 25 to 125 1 0 to 150 o o 20 to 240 2 o o o 50 to 250 2 0 to 250 o o o 50 to 300 2 0 to 300 o o o 50 to 400 5 100 to 400 o o 50 to 500 5 o o 150 to 750 10 o o *200 to 1000 10 O * NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F. DIV o 1 o 1 o 1 o 1/2 o 1 o 1 BIMETAL THERMOMETERS BACK CONNECTED INDUSTRIAL THERMOMETERS Model GT-200 o 2 o 5 o 5 Model LN-250R Page 83 BACK CONNECTED INDUSTRIAL THERMOMETERS AVAILABLE IN 3” AND 5” DIAL SIZES FEATURES • • • • • • • • • • • • • Model GT-300R Model GT-500R 18-8 Type 304 stainless steel. Model numbered GT-300R and GT-500R easy to recalibrate with Hex Screw. Connection Nut: 1/2” N.P.T. standard, can be supplied in other sizes at extra charge. Anti-Parallax dial avoids reading errors. White dial with large Black numbers and graduations on raised ring for surest, sharpest, easiest readability. All welded construction. Head diameters: 3” and 5”. Rustproof - Dustproof - Leakproof - Hermetically sealed. Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”, including threads. Available in stem lengths up to 72”. Extra-heavy glass crystal. Plastic or tempered crystal can be supplied at extra charge. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer. Guaranteed accurate with 1% around entire dial range. o o Over-range protection 50% up to 500 F, 10% above 500 F. STANDARD DIALo RANGES FAHRENHEIT /DIV CENTIGRADE o o o -100 to 100 2 -50 to 100 o o o -40 to 160 2 -50 to 25 o o o 0 to 140 2 -10 to 110 o o o 0 to 180 2 **0 to 50 o o o 0 to 220 2 0 to 100 o o o 25 to 125 1 0 to 150 o o 20 to 240 2 o o o 50 to 250 2 0 to 250 o o o 50 to 300 2 0 to 300 o o o 50 to 400 5 100 to 400 o o 50 to 500 5 o o 150 to 750 10 o o *200 to 1000 10 O * NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F. Special Dial Ranges and Stem Lengths Available at Extra Charge. DIV o 1 o 1 o 1 o 1/2 o 1 o 1 o 2 o 5 o 5 AVAILABLE IN 3” AND 5” DIAL SIZES FEATURES • • • • • • • • • • • • • 18-8 Type 304 stainless steel. Model numbered BC350R and BC550R easy to recalibrate with Hex Screw. Connection Nut: 1/2” N.P.T. standard, can be supplied in other sizes at extra charge. Anti-Parallax dial avoids reading errors. White dial with large Black numbers and graduations on raised ring for surest, sharpest, easiest readability. All welded construction. Head diameters: 3” and 5”. Rustproof - Dustproof - Leakproof - Hermetically sealed. Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”, including threads. Available in stem lengths up to 72”. Extra-heavy glass crystal. Plastic or tempered crystal can be supplied at extra charge. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer. Guaranteed accurate with 1% around entire dial range. o o Over-range protection 50% up to 500 F, 10% above 500 F. STANDARD DIALo RANGES FAHRENHEIT /DIV CENTIGRADE o o o -100 to 100 2 -50 to 100 o o o -40 to 160 2 -50 to 25 o o o 0 to 140 2 -10 to 110 o o o 0 to 180 2 **0 to 50 o o o 0 to 220 2 0 to 100 o o o 25 to 125 1 0 to 150 o o 20 to 240 2 o o o 50 to 250 2 0 to 250 o o o 50 to 300 2 0 to 300 o o o 50 to 400 5 100 to 400 o o 50 to 500 5 o o 150 to 750 10 o o *200 to 1000 10 O * NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F. Special Dial Ranges and Stem Lengths Available at Extra Charge. BIMETAL THERMOMETERS BOTTOM CONNECTED INDUSTRIAL THERMOMETERS Model BC-350R DIV o 1 o 1 o 1 o 1/2 o 1 o 1 o 2 o 5 o 5 Model BC-550R Page 85 ADJUSTABLE ANGLE INDUSTRIAL THERMOMETERS AVAILABLE IN 3” AND 5” DIAL SIZES FEATURES • • • • • • • • • • • • • 18-8 Type 304 stainless steel. Model numbered AA-375R and AA-575R easy to recalibrate with Hex Screw. Connection Nut: 1/2” N.P.T. standard, can be supplied in other sizes at extra charge. Anti-Parallax dial avoids reading errors. White dial with large Black numbers and graduations on raised ring for surest, sharpest, easiest readability. All welded construction. Head diameters: 3” and 5”. Rustproof - Dustproof - Leakproof - Hermetically sealed. Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”, including threads. Available in stem lengths up to 72”. Extra-heavy glass crystal. Plastic or tempered crystal can be supplied at extra charge. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer. Guaranteed accurate with 1% around entire dial range. o o Over-range protection 50% up to 500 F, 10% above 500 F. STANDARD DIALo RANGES FAHRENHEIT /DIV CENTIGRADE o o o -100 to 100 2 -50 to 100 o o o -40 to 160 2 -50 to 25 o o o 0 to 140 2 -10 to 110 o o o 0 to 180 2 **0 to 50 o o o 0 to 220 2 0 to 100 o o o 25 to 125 1 0 to 150 o o 20 to 240 2 o o o 50 to 250 2 0 to 250 o o o 50 to 300 2 0 to 300 o o o 50 to 400 5 100 to 400 o o 50 to 500 5 o o 150 to 750 10 o o *200 to 1000 10 O * NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F. Special Dial Ranges and Stem Lengths Available at Extra Charge. IMMERSE STEM AT LEAST 2” IN LIQUIDS, 4” IN GASES DIV o 1 o 1 o 1 o 1/2 o 1 o 1 o 2 o 5 o 5 BIMETAL THERMOMETERS SPECIAL USE DIAL THERMOMETERS MODEL MX325 Recalibrator The red manually operated reset pointer is turned by the center knob against either the high or low side of the permanent indicating pointer. MODEL PT50R The manual reset pointer will move up or down the range remaining at maximum or minimum temperature reading. At a glance gives present temperature together with maximum or minimum temperature since last reset. Avoid uses subject to excessive vibration. FEATURES • • • • • • • • • • • • • • • 18-8 Type 304 stainless steel construction. Corrosion resistant to most chemicals. Rustproof - Dustproof - Leakproof. Head diameter 1” - Stem 5” long by .150” diameter. White dial with large numbers and graduations easy to read from any angle. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer. Guaranteed accurate within 1/2 of 1% around dial range. Durable - Non-Fragile - Safe to Handle. o o Over range protection is 50% up to 500 F, and 10% over 500 F. Lucite unbreakable crystal - no glass to break. o Glass crystal used for temperatures over 220 F. Available Fahrenheit or Centigrade. Hard rubber carrying case with attached pencil clip. Hermetically Sealed. FEATURES • • • • • • • • • • • STANDARD DIALo RANGES FAHRENHEIT o 25 to 125 o -40 to 160 o 0 to 220 o 50 to 500 /DIV o 1 o 2 o 2 o 5 CENTIGRADE o 0 to 150 o 0 to 250 o -10 to 110 DIV o 1 o 2 o 1 • • 18-8 Type 304 stainless steel. All welded construction. Model MX 325R easy to recalibrate by loosening 3 screws on back. Anti-Parallax dial avoids reading errors. White dial with large, black numbers and graduations on raised ring for surest, sharpest, easiest readability. Head diameter 3”. Rustproof - Dustproof - Leakproof. Connection Nut: 1/2” N.P.T. standard, can be supplied in other sizes at extra charge. Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”, including threads. Available in stem lengths up to 72”. Actuated by super-sensitive bi-metallic Helix Coil - No Liquids. Bi-metallic element dampened with silicone for minimum pointer vibration and maximum heat transfer. Normal temperature indication accurate within 1% around entire dial range. Max. or Min. temperature indication accurate within 1 1/2% o o over-range protection 50% up to 500 F, 10% above 500 F. Extra-heavy glass crystal. Plastic or tempered crystal can be supplied at extra charge. Page 87 SURFACE TEMPERATURE BIMETAL DIAL THERMOMETERS 2” DIAMETER DUAL MAGNET SURFACE TEMPERATURE THERMOMETERS ARE DESIGNED TO MEASURE TEMPERATURES OF MANY DIFFERENT SURFACES. THE BASE OF THE UNIT IS PLACED ON THE SURFACE TO BE MEASURED. THE SENSING ELEMENT THEN DIRECTLY CONTACTS THE SURFACE; EXPANSION OR CONTRACTION OF THE BIMETAL ELEMENT RESULTS IN DIAL READOUT. HEIGHT: 1/2” ACCURACY: +/-2% FULL SCALE RANGE. CAT NO 312F 313F 314F 315F 330F TEMP RANGE, FAHRENHEIT CAT NO 0 to 250OF 0 to 500OF 50 to 750OF 0 to 150OF -110 to 160OF TEMP RANGE, CELSIUS 312C 313C 314C 315C 330C -20 to 120OC -20 to 250OC 10 to 400OC -20 to 65OC -70 to 70OC RANGES AND ORDERING INFORMATION STANDARD DIAL RANGES FAHRENHEIT º/DIV CENTIGRADE º/DIV 2º -75 to 175º (B) 5º -40 to 160º 2º -50 to 100º 1º 0 to 140º2º -50 to 25º 1º 0 to 180º2º -10 to 110º (a) 1º 0 to 220º (a) 2º 0 to 50º 1/2º 20 to 240º 2º 0 to 100º 1º 25 to 125º (a) 1º 0 to 150º (a) 1º 50 to 250º 2º 0 to 200º 2º 50 to 300º 2º 0 to 250º (a) 2º 50 to 400º 5º 0 to 300º 5º 50 to 500º (a) 5º 100 to 400º 5º 150 to 750º 10º *200 to 1000º 10º -100 to 100º * NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800ºF. (a) MODEL PT-50 AVAILABLE IN THESE RANGES ONLY. (b) 3” INDUSTRIAL SIZE ONLY. ORDERING INSTRUCTIONS Create catalog number by combining the following: (Model No.) + (Top Range of Thermometer) + (‘F’ or ‘C’) + (Stem Length) Example: GT100R 50 to 500F 8 in. Stem (GT100R) + (500) + (F) = (8) = GT100R500F8 Example: BC350R 0 to 140F 2-1/2 (2.5”) in. Stem (BC350R) + (140) + (F) = (2.5) = BC350R140F2 *BE SURE TO SPECIFY ANY UNUSUAL APPLICATION SUCH AS OVERRANGE, HIGH PRESSURE OR CORROSIVE CONDITIONS. GIVE DETAILS. * IF HEAD IS TO BE SUBJECTED TO TEMPERATURES IN EXCESS OF 300F, STATE TEMPERATURE. Special Quotation on Request for: •Special stem lengths •Plastic crystals (standard on PT50R, GT100R, LT225R) •Special connection nut sizes. • • • • Designed and manufactured to assure a perfect alignment of thermometer and sensing element. Industry Standard will fit the thermometers of all manufacturers. Machined from solid bar stock-304 Stainless steel. high quality of material and workmanship. STANDARD THERMOWELL THERMOMETER STEM LENGTH THERMOWELL # 304 SS 3/4” NTP 2 1/2” 4” 6” 9” 12” 18” 24” 36” TW02.5 TW04 TW06 TW09 TW12 TW18 TW24 TW36 BIMETAL THERMOMETERS BIMETAL DIAL THERMOMETER WELLS BUSHINGS FOR THERMOWELLS Page 89 COMMENTARY Page 91 THE NON-MERCURIAL THERMOMETERS: JUST HOW GOOD ARE THEY? Spirit thermometers, whether alcohol or mineral spirit filled, have a reputation for being inaccurate which is not entirely deserved. Excellent accuracy and repeatability can be obtained with spirit thermometers provided the manufacturer recognizes the differing characteristics of the media - and how each differs from mercury - and adjusts his manufacturing and calibration procedures accordingly. liquid column ends. Performing this equipment needed and that the traditional procedure over a series of temperatures acid etching procedure for marking the glass results in a series of reference marks on the be utilized. It would be virtually impossible Firstly, the media: the terms ‘alcohol’ thermometer stem which allows definition for a high volume producer who uses decals and ‘mineral spirits’ (as well as toloul, and placement of the graduations which and/or silk screening procedures for his ther- butanol and pentane) are often referred to make up the scale. Let us suppose the mometer markings to produce simply as ‘spirit’ with little or no distinction. example of a -10/250C range thermometer. thermometers of this caliber. Each material, however, has different De facto industry standardsfor a mercury characteristics and is appropriate for thermometer would suggest defining the differing temperature applications. In our ‘points’ of 0 and 200C; by interpolation opinion, alcohol is an excellent medium for and extrapolation a graduated scale can be low temperature applications within the devised which will yield satisfactory temperature limits of approximately -100C accuracy assuming: to +50C. We use butanol for temperatures 1) a linear curve of expansion (mercury is A weakness, even of well-designed and well- below -100C down to approximately -200C. very linear) and made non-mercurial thermometers, relates to We discontinued the use of Tuloul and 2) a perfectly uniform capillary tubing those designed for partial Tolune altogether a number of years ago within the thermometer. immersion. Since the volume of the EXACTLY WHAT IS.... SPIRIT? capillary must be somewhat larger than that when these items were placed on the of a similar mercury thermometer, there is suspected carcinogen list. Mineral spirits have a workable range from -30C to +200C under normal circumstances and up to SO WHAT ARE THE NEGATIVES TO CONSIDER? MULTIPLE CALIBRATION POINTS ARE NEEDED more liquid exposed to ambient temperatures which can vary widely. The influence of this ambient temperature can 250C if correctly pressurized. KESSLER has always been cautious on affect the indication of the thermometer, per- Secondly, cleanliness: Thermometers assumptions which affect the accuracy of haps markedly. Partial immersion in general must be CLEAN to function well the instrument. Accordingly our thermometers are calibrated anticipat- and have a long, accurate life. Clean in this procedures call for three, not two, ing indoor, climate controlled conditions context means not just the absence of dirt calibrations points on a -10/250C mercury (25C (77F) is often cited as the standard). and visible impurities but also the absence thermometer. Consider that partial immersion thermometer being used for outdoor testing during a frigid of moisture and oxygen in the sealed instru- Alaskan winter or during midday in July in ment. SPECIALIZED GRADUATING EQUIPMENT IS A MUST CALIBRATION (CHARTING IS OF PARAMOUNT IMPORTANCE ation for ALL partial immersion thermometers; ‘spirit’ thermometers are simply more sensi- THE CURVE OF EXPANSION OF THE MEDIUM) Arizona. Conditions of use are a consider- A mineral spirits thermometer is entirely tive to changes in ambient temperatures that another challenge. We have determined their mercury that in order to obtain acceptable accuracy, counterparts. Thirdly, proper calibration: Let me we must calibrate this thermometer at 0, 50, use an illustration. Calibration in this 100, 150, 200 and 250C; spacing of the context means to subject an ungraduated graduations changes somewhat between thermometer to a known, carefully each pair of points, while adjusting for the controlled temperature under correct non-linear expansion curve of the medium. conditions of immersion, allow it to come to This type of adjusted spacing requires that equilibrium and mark the stem where the the manufacturer has the graduating HOW ABOUT SEPARATIONS IN THE COL- Partial Immersion: The second downside to spirit thermometers +/- one scale division low scale. is the tendency for the liquid column to separate. This separation of the liquid +/- 1.5 scale division high scale column is a condition and NOT a defect. Separations occur primarily in shipping or ie. on a -10/250C partial immersion when stored for long periods of time in a thermometer we would call 0 degrees low horizontal position. The preferred storage scale, 125 degrees mid scale, 250C high mode is in a vertical position (such as in our scale. thermometer rack) when not in use. Complete instructions for rejoining separations are included with all KESSLER COMMENTARY UMN? FOR TECHNICAL INFORMATION PLEASE CONSULT FACTORY. thermometers; as ever, if you experience difficulty, please phone us for no charge technical service. HOW ABOUT RESPONSE TIME? A third (potentially negative) characteristic to consider is response time. Typically non-mercurial thermometers take longer to come to equilibrium than their mercury counterparts, normally by a factor of approximately 50%. While this is not significant is most applications, certain procedures which require an extremely quick response time (such as a melt point index) may not be good candidates for use of a non-mercurial thermometer. It is in consideration of all above concerns that KESSLER has defined the following accuracy requirements for our non-mercurial thermometers: Total Immersion: +/- one scale division, full scale. Page 93 For more information, please contact us: ExpotechUSA 10700 Rockley Road Houston, Texas 77099 USA 281-496-0900 [voice] 281-496-0400 [fax] E-mail: sales@expotechusa.com Website: www.ExpotechUSA.com