60
KESSLER TABLE
HERMOMETER
CORP.
OF CONTENTS
ISO 9002 REGISTERED
ASTM THERMOMETERS
ASTM CERTIFIED THERMOMETERS
11 - 19
24 - 29
FRACTIONAL DEGREE THERMOMETERS
31 - 33
LABORATORY THERMOMETERS
35 - 37
DEEP IMMERSION/VARI-IMMERSION
39 - 41
ENVIRONMENTAL CHAMBER
43 - 45
POCKET, MAXIMUM, SPECIALTY
47 - 49
JOINTED THERMOMETERS
51 - 53
GAUGING EQUIPMENT
55 - 59
ACCESSORIES
CALIBRATION EQUIPMENT
HYDROMETERS
BI-METAL
COMMENTARY
61
65
69
81
91
-
63
67
79
89
93
Page 7
For more information, please contact us:
ExpotechUSA
10700 Rockley Road
Houston, Texas 77099
USA
281-496-0900 [voice]
281-496-0400 [fax]
E-mail: sales@expotechusa.com
Website: www.ExpotechUSA.com
CONVERSION SCALES
THE CONVERSION TABLE MAY BE USED FOR CONVERTING DEGREES FAHRENHEIT TO DEGREES CENTIGRADE OR VICE VERSA. BOLD
FACE NUMBERS IN THE CENTER REFER TO THE KNOWN TEMPERATURE IN EITHER CENTIGRADE OR FAHRENHEIT. EQUIVALENT
TEMPERATURE IS FOUND IN THE APPROPRIATE LEFT OR RIGHT COLUMN.
FORMULA FOR CONVERTING TEMPERATURE SCALES
ABOVE 0
BELOW 0
O
O
TO CONVERT FAHRENHEIT READINGS TO CENTIGRADE:
SUBTRACT 32 DEGREES AND DIVIDE THE REMAINDER BY 1.8.
TO CONVERT FAHRENHEIT READINGS TO CENTIGRADE:
ADD 32 DEGREES AND DIVIDE THE REMAINDER BY 1.8
TO CONVERT CENTIGRADE READING TO FAHRENHEIT:
MULTIPLY BY 1.8 AND ADD 32 DEGREES TO THE RESULT.
TO CONVERT CENTIGRADE READING TO FAHRENHEIT:
MULTIPLY BY 1.8 AND SUBTRACT 32 DEGREES FROM THE RESULT.
Page 9
ASTM
THERMOMETERS
Page 11
KESSLER’s rigid manufacturing tolerance and inspection ensure the production of ASTM thermometers that are well
within the dimensional and accuracy specifications of E-1 and E-77 of the AMERICAN SOCIETY FOR TESTING AND
MATERIALS (ASTM). To order a copy of test method E-77, please use catalog number ASTM E-77.
PARTIAL IMMERSION
ASTM
1C
1F
2C
2F
3C
3F
IP
CAT NO
APPLICATION
Partial
Partial
Partial
Partial
Partial
TEMP RANGE
DIV
LENGTH
IMMERSION
62C
62F
73C
1102
1104
1106
1108
1110
73F
1112
Partial Immersion
20 to 760OF
2
415mm
76mm
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
1000
Acid Heat
30 to 220OF
1
375mm
152mm
Immersion
Immersion
Immersion
Immersion
Immersion
-20 to 150OC
0 to 302OF
-5 to 300OC
20 to 580OF
-5 to 400OC
1
2
1
2
1
322mm
322mm
390mm
390mm
415mm
76mm
76mm
76mm
76mm
76mm
ACID HEAT
ASTM
4C
IP
1002
4F
Acid Heat
-1 to 105OC
0.5
375mm
152mm
CLOUD AND POUR - LOW AND HIGH
ASTM
5C
5F
6C
1C
1F
2C
IP
CAT NO
1006
1004
1010
Cloud & Pour, High
Cloud & Pour, High
Cloud & Pour, Low
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
6F
2F
1008
Cloud & Pour, Low
-112 to 70OF
2
230mm
76mm
-38 to 50OC
-36 to 120OF
-80 to 20OC
1
2
1
230mm
230mm
230mm
l08mm
l08mm
76mm
DISTILLATION - LOW AND HIGH
ASTM
7C
7F
8C
IP
5C
CAT NO
6C
8F
1014
1012
1018
APPLICATION
Distillation, Low
Distillation, Low
Distillation, High
TEMP RANGE
DIV
LENGTH
IMMERSION
1016
Distillation, High
30 to 760OF
2
385mm
total
-2 to 300OC
30 to 580OF
-2 to 400OC
1
2
1
385mm
385mm
385mm
total
total
total
PENSKY-MARTENS - LOW AND HIGH
ASTM
9C
9F
10C
15C
15F
16C
IP
CAT NO
1022
1020
1026
Pensky-Martens Low
Pensky-Martens Low
Pensky-Martens High
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
10F
16F
1024
Pensky-Martens High
200 to 700OF
5
290mm
57mm
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
-5 to 110OC
20 to 230OF
90 to 370OC
0.5
1
2
290mm
290mm
290mm
57mm
57mm
57mm
OPEN FLASH
ASTM
11C
11F
IP
28C
28F
1038
1036
Open Flash
Open Flash
-6 to 400OC
20 to 760OF
2
5
310mm
310mm
25mm
25mm
DENSITY - WIDE RANGE (GRAVITY)
ASTM
12C
12F
IP
64C
64F
CAT NO
1042
1040
Gravity
Gravity
-20 to 102OC
-5 to 215OF
0.2
0.5
420mm
420mm
total
total
LOSS ON HEAT
ASTM
13C
IP
47C
CAT NO
1048A
Loss on Heat
155 to 170OC
0.5
155mm
total
1010
PARAFFIN WAX MELTING POINT
ASTM
14C
14F
IP
17C
17F
CAT NO
1051
1050
APPLICATION
Paraffin Wax Melt Pt.
Paraffin Wax Melt Pt.
38 to 82OC
100 to 180OF
0.1
0.2
375mm
375mm
79mm
79mm
1102
1042
ASTM THERMOMETERS
SOFTENING POINT
ASTM
15C
15F
16C
16F
IP
60C
CAT NO
1056
1054
1060
1058
61C
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
Softening Pt. Low
Softening Pt. Low
Softening Pt. High
Softening Pt. High
-2 to 80OC
30 to 180OF
30 to 200OC
85 to 392OF
0.2
0.5
0.5
1
397mm
397mm
397mm
397mm
total
total
total
total
SAYBOLT VISCOSITY
ASTM
17C
17F
18C
18F
19C
19F
20C
20F
21C
21F
22C
22F
IP
CAT NO
1085
1066
1086
1067
1087
1068
1088
1069
1089
1075
1090
1076
23C
23F
24C
24F
Viscosity Saybolt
Viscosity Saybolt
Say Vis & Reid Vapor
Say Vis & Reid Vapor
Viscosity Saybolt
Viscosity Saybolt
Viscosity Saybolt
Viscosity Saybolt
Viscosity Saybolt
Viscosity Saybolt
Say Vis & Oxy Stab.
Say Vis & Oxy Stab.
19 to 27OC
66 to 80OF
34 to 42OC
94 to 108OF
49 to 57OC
120 to 134OF
57 to 65OC
134 to 148OF
79 to 87OC
174 to 188OF
95 to 103OC
204 to 218OF
0.1
0.2
0.1
0.2
0.1
0.2
0.1
0.2
0.1
0.2
0.1
0.2
275mm
275mm
275mm
275mm
275mm
275mm
275mm
275mm
275mm
275mm
275mm
275mm
total
total
total
total
total
total
total
total
total
total
total
total
ENGLER VISCOSITY
ASTM
23C
24C
25C
IP
CAT NO
1092
1093
1094
Viscosity Engler
Viscosity Engler
Viscosity Engler
18 to 28OC
39 to 54OC
95 to 105OC
0.2
0.2
0.2
212mm
237mm
212mm
90mm
90mm
90mm
STABILITY TEST OF SOLUBLE NITROCELLULOSE
ASTM
26C
IP
CAT NO
1120
APPLICATION
Stab Test Sot Nit Cell
130 to 140OC
0.1
463mm
total
TURPENTINE DISTILLATION
ASTM
27C
IP
CAT NO
1122
APPLICATION
Turpentine Dist.
147 to 182OC
0.5
301mm
76mm
KINEMATIC VISCOSITY
ASTM
28C
28F
29C
29F
30F
IP
31C
31F
34C
34F
32F
CAT NO
1097G
1096G
1097I
1096I
1096M
Kinematic Viscosity
Kinematic Viscosity
Kinematic viscosity
Kinematic Viscosity
Kinematic viscosity
APPLICATION
36.6 to 39.4OC
97.5 to 102.5OF
52.6 to 55.4OC
127.5 to 132.5OF
207.5 to 212.5OF
TEMP RANGE
0.05
0.1
0.05
0.1
0.1
DIV
LENGTH
IMMERSION
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
305mm
305mm
305mm
305mm
305mm
total
total
total
total
total
REID VAPOR
ASTM
31F
IP
1003
Reid Vapor
-30 to 120OF
1
305mm
total
ANILINE POINT
ASTM
33C
33F
34C
34F
35C
35F
IP
20F
21F
59F
1126
1127
1128
1129
1130
1131
Aniline
Aniline
Aniline
Aniline
Aniline
Aniline
Point
Point
Point
Point
Point
Point
-38 to 42OC
-36.5 to 107.5OF
25 to 105OC
77 to 221OF
90 to 170OC
194 to 338OF
0.2
0.5
0.2
0.5
0.2
0.5
420mm
420mm
420mm
420mm
420mm
420mm
50mm
50mm
50mm
50mm
50mm
50mm
1056
TITER TEST
ASTM
36C
IP
1272
Titer Test
-2 to 68ºC
0.2
405mm
45mm
Page 13
SOLVENTS DISTILLATION
ASTM
37C
38C
39C
40C
41C
42C
IP
77C
78C
79C
80C
81C
82C
CAT NO
APPLICATION
1132
1134
1136
1138
1140
1142
Solvents Distillation
Solvents Distillation
Solvents Distillation
Solvents Distillation
Solvents Distillation
Solvents Distillation
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
-2 to 52OC
24 to 78OC
48 to 102OC
72 to 126OC
98 to 152OC
95 to 255OC
0.2
0.2
0.2
0.2
0.2
0.5
395mm
395mm
395mm
395mm
395mm
395mm
100mm
l00mm
100mm
l00mm
100mm
100mm
KINEMATIC VISCOSITY
ASTM
43C
43F
44C
44F
45C
45F
46C
46F
47C
47F
48C
48F
IP
65C
65F
29C
29F
30C
30F
66C
66F
35C
35F
90C
90F
CAT NO
APPLICATION
1097B
1096B
1096Q
1096E
1096R
1096F
1096S
1096H
1096T
1096K
1097L
1096L
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic viscosity
Kinematic viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
-51.6 to -34OC
-61 to -29OF
18.5 to 21.5OC
66.5 to 71.5OF
23.6 to 26.4OC
74.5 to 79.5OF
48.6 to 51.4OC
19.5 to 124.5OF
58.6 to 61.4OC
137.5 to 142.5OF
80.6 to 83.4OC
177.5 to 182.5OF
DIV
0.1
0.2
0.05
0.1
0.05
0.1
0.05
0.1
0.05
0.1
0.05
0.1
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
19 to 35OC
66 to 95OF
0.02
0.05
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
417mm
417mm
305mm
305mm
305mm
305mm
305mm
305mm
305mm
305mm
305mm
305mm
total
total
total
total
total
total
total
total
total
total
total
total
STORMER VISCOSITY
ASTM
49C
IP
CAT NO
1095
Stormer Viscosity
20 to 70OC
0.2
305mm
65mm
GAS CALORIMETER
ASTM
50F
51F
IP
CAT NO
1144
1146
Gas Calorimeter inlet
Gas Calorimeter inlet
54 to 101OF
69 to 116OF
0.1
0.1
468mm
468mm
total
total
BUTADINE BOILING POINT
ASTM
52C
IP
CAT NO
1148
APPLICATION
Butadine Boiling Pt.
-10 to 5OC
0.1
162mm
total
BENZENE FREEZING POINT
ASTM
53C
IP
CAT NO
1148C
Benzene Freezing Pt.
-0.6 to 10.4OC
0.1
189mm
total
CONGEALING POINT
ASTM
54C
54F
IP
18C
18F
CAT NO
1048
1047
Congealing Point
Congealing Point
20 to 100.6OC
68 to 213OF
0.2
0.5
310mm
310mm
total
total
BOMB CALORIMETER
ASTM
56C
56F
IP
CAT NO
1147
1147A
Bomb Calorimeter
Bomb Calorimeter
585mm
585mm
total
total
TAG CLOSED TESTER
ASTM
57C
57F
IP
CAT NO
1034
1032
Flash Tag Closed Low
Flash Tag Closed Low
-20 to 50OC
-4 to 122OF
0.5
1
290mm
290mm
1272
57mm
57mm
1096E
ASTM THERMOMETERS
TANK GAUGING – REFILL
ASTM
58C
58F
59C
59F
60C
60F
IP
CAT NO
1248
1252
1253
1256
1257
1260
APPLICATION
Tank, Refill, Low
Tank, Refill, Low
Tank, Refill, Medium
Tank, Refill, Medium
Tank, Refill, High
Tank, Refill, High
TEMP RANGE
-34 to 49OC
-30 to 120OF
-18 to 82OC
0 to 180OF
77 to 260OC
170 to 500OF
DIV
0.5
1
0.5
1
1
2
LENGTH
300mm
300mm
300mm
300mm
300mm
300mm
IMMERSION
total
total
total
total
total
total
ANY OF THE ABOVE MAY BE FURNISHED WITH RED READING LENS GLASS AT ADDITIONAL COST. ADD SUFFIX“RRL” TO CATALOG
NUMBER.
PETROLATUM MELT POINT
ASTM
61C
61F
IP
16C
CAT NO
1053
1052
APPLICATION
Petrolatum Melt Pt.
Petrolatum Melt Pt.
TEMP RANGE
32 to 127OC
90 to 260OF
DIV
0.2
0.5
LENGTH
380mm
380mm
IMMERSION
79mm
79mm
ASTM PRECISION SERIES
• ETCHED STEM MERCURY-IN-GLASS THERMOMETERS MANUFACTURED IN STRICT ACCORDANCE WITH ASTM AND NATIONAL INSTITUTE
OF STANDARDS AND TECHNOLOGY (FORMERLY NBS) SPECIFICATIONS.
• EXTENSIVELY AGED AND ANNEALED FOR MINIMAL SCALE ERROR AND EXTENDED LIFE.
• AUXILIARY ICE POINT REFERENCE SCALE FOR VERIFICATION OF MAIN SCALE CORRECTIONS.
ASTM
62C
63C
64C
65C
66C
67C
68C
69C
70C
1296
COMPLETE
ASTM
62F
63F
64F
65F
66F
67F
68F
69F
70F
1298
IP
2C
61C
12C
43C
46C
72C
73C
74C
CAT NO
1300
1302
1304
1306
1308
1310
1312
1314
1316
SET OF
IP
2F
12F
43F
46F
72F
73F
74F
COMPLETE
CELSIUS
APPLICATION
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
RANGES
CAT NO
1320
1322
1324
1326
1328
1330
1332
1334
1336
SET OF
FAHRENHEIT
ASTM 62C
TEMP RANGE
-38 to 2OC
-8 to 32OC
25 to 55OC
50 to 80OC
75 to 105OC
95 to 155OC
145 to 205OC
195 to 305OC
295 to 405OC
THROUGH
APPLICATION
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
RANGES
ASTM 62F
70C
LENGTH
379mm
379mm
379mm
379mm
379mm
379mm
379mm
379mm
379mm
IMMERSION
total
total
total
total
total
total
total
total
total
FURNISHED IN A VELVET-LINED PROTECTIVE CASE.
TEMP RANGE
-36 to 35OF
18 to 89OF
77 to 131OF
122 to 176OF
167 to 221OF
203 to 311OF
293 to 401OF
383 to 581OF
563 to 761OF
THROUGH
DIV
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.5
0.5
70F
DIV
0.2
0.2
0.2
0.2
0.2
0.5
0.5
1.0
1.0
LENGTH
379mm
379mm
379mm
379mm
379mm
379mm
379mm
379mm
379mm
IMMERSION
total
total
total
total
total
total
total
total
total
1256
FURNISHED IN A VELVET-LINED PROTECTIVE CASE.
1308
Page 15
OIL IN WAX
ASTM
71C
71F
CAT NO
1293A
1293
APPLICATION
Oil in Wax
0il in Wax
TEMP RANGE
-37 to 21OC
-35 to 70OF
DIV
LENGTH
IMMERSION
0.5
1
355mm
355mm
76mm
76mm
KINEMATIC VISCOSITY
ASTM
72C
72F
73C
73F
74C
74F
CAT NO
1097A
1096A
1096U
1096C
1096D
10960
APPLICATION
-19.4 to -16.6OC
-2.5 to +2.5OF
-41.4 to -38.6OC
-42.5 to -37.5OF
-55.4 to -52.6OC
-67.5 to -62.5OF
0.05
0.1
0.05
0.1
0.05
0.1
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic viscosity
TEMP RANGE
305mm
305mm
305mm
305mm
305mm
305mm
total
total
total
total
total
total
COOLANT FREEZING POINT
ASTM
75F
76F
CAT NO
1200
1202
Coolant Freezing Pt.
Coolant Freezing Pt.
-35 to 35OF
-65 to +5OF
0.5
0.5
408mm
408mm
100mm
100mm
SAYBOLT VISCOSITY
ASTM
77F
78F
79F
80F
81F
CAT NO
1077
1079
1080
1082
1084
Viscosity
Viscosity
Viscosity
Viscosity
Viscosity
Saybolt
Saybolt
Saybolt
Saybolt
Saybolt
245
295
345
395
445
to
to
to
to
to
265OF
315OF
365OF
415OF
465OF
0.5
0.5
0.5
0.5
0.5
275mm
275mm
275mm
275mm
275mm
total
total
total
total
total
FUEL RATING
ASTM
82F
82C
83F
83C
84F
84C
85F
85C
86F
86C
87F
87C
CAT NO
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
Fuel Rating, Engine
Fuel Rating, Engine
Fuel Rating, Air
Fuel Rating, Air
Fuel Rating, Orifice
Fuel Rating, Orifice
Fuel Rating, Surge
Fuel Rating, Surge
Fuel Rating, Mix
Fuel Rating, mix
Fuel Rating, Coolant
Fuel Rating, Coolant
0 to 220OF
-15 to 105OC
60 to 160OF
15 to 70OC
75 to 175OF
25 to 80OC
100 to 300OF
40 to 1S0OC
200 to 350OF
95 to 174OC
300 to 400OF
150 to 205OC
2
1
1
1
1
1
2
1
2
1
1
1
165mm
165mm
174mm
174mm
387mm
387mm
314mm
314mm
170mm
170m
175mm
175mm
30mm
30mm
40mm
40mm
249m
249m
181mm
181mm
35mm
35mm
40mm
40mm
VEGETABLE OIL FLASH
ASTM
88C
88F
CAT NO
1216
1218
APPLICATION
Vegetable Oil Flash
Vegetable Oil Flash
10 to 200OC
50 to 392OF
1
2
287mm
287mm
57mm
57mm
SOLIDIFICATION POINT
ASTM
89C
90C
91C
92C
93C
94C
95C
96C
CAT NO
1220
1222
1224
1226
1228
1230
1232
1234
APPLICATION
Solidification
Solidification
Solidification
Solidification
Solidification
Solidification
Solidification
Solidification
Point
Point
Point
Point
Point
Point
Point
Point
-20 to +10OC
0 to 30OC
20 to 50OC
40 to 70OC
60 to 90OC
80 to 110OC
100 to 130OC
120 to 150OC
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
370mm
370mm
370mm
370mm
370mm
370mm
370mm
370mm
76mm
76mm
76mm
76mm
76mm
76mm
76mm
76mm
TANK GAUGING – REFILL
ASTM
97C
97F
98C
98F
CAT NO
1244
1262
1246
1264
APPLICATION
TEMP RANGE
DIV
LENGTH
Tank, Refill
-18 to 49OC
0.5
300mm
Tank, Refill
0 to 120OF
1
300mm
Tank, Refill
16 to 82OC
0.5
300mm
Tank, Refill
60 to 180OF
1
300mm
(FOR COMPLETE UNITS AND CASES, SEE GAUGING SECTION, PAGE #)
IMMERSION
total
total
total
total
1220
1082
1214
ASTM THERMOMETERS
WEATHERING TEST
ASTM
99F
99C
CAT NO
APPLICATION
1278
1279
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
Weathering Test
Weathering Test
-58 to 41OF
-50 to +5OC
0.5
0.2
305mm
305mm
35mm
35mm
SOLIDIFICATION POINT
ASTM
100C
101C
CAT NO
APPLICATION
1236
1238
Solidification Point
Solidification Point
145 to 205OC
195 to 305OC
0.2
0.5
370mm
370mm
76mm
76mm
SOLVENTS DISTILLATION
ASTM
102C
103C
104C
105C
106C
107C
CAT NO
1266
1268
1270
1273
1274
1276
Solvents
Solvents
Solvents
Solvents
Solvents
Solvents
Distillation
Distillation
Distillation
Distillation
Distillation
Distillation
123
148
173
198
223
248
to
to
to
to
to
to
177OC
202OC
227OC
252OC
277OC
302OC
0.2
0.2
0.2
0.2
0.2
0.2
395mm
395mm
395mm
395mm
395mm
395mm
l00mm
100mm
100mm
100mm
100mm
l00mm
SAYBOLT VISCOSITY
ASTM
108F
109F
CAT NO
1091A
1091B
Viscosity Saybolt
Viscosity Saybolt
270 to 290OF
320 to 340OF
0.5
0.5
275mm
275mm
total
total
KINEMATIC VISCOSITY
ASTM
110C
110F
CAT NO
APPLICATION
1096V
1096N
133.6 to 136.4OC
272.5 to 277.5OF
0.05
0.1
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
APPLICATION
Bomb Calorimeter
Bomb Calorimeter
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
DIV
LENGTH
IMMERSION
Kinematic viscosity
Kinematic Viscosity
TEMP RANGE
305mm
305mm
total
total
TAR ACID DISTILLATION
ASTM
111C
CAT NO
1284
APPLICATION
Tar Acid Distillation
170 to 250OC
0.2
395mm
100mm
SOLIDIFICATION POINT OF BENZENE
ASTM
112C
CAT NO
1286
APPLICATION
Solidification Benzene
TEMP RANGE
4 to 6OC
0.02
220mm
total
BITUMINOUS MATERIALS SOFTENING POINT
ASTM
113C
CAT NO
APPLICATION
1289
Bit. Mat. Sftn. Pt.
-1 to 175OC
0.5
4O6mm
total
AVIATION FUELS FREEZING POINT
ASTM
114C
114F
CAT NO
1290
1291
Aviation Fuel Frz. Pt.
Aviation Fuel Frz. Pt.
-80 to 20OC
-112 to 70OF
0.5
1.0
300mm
300mm
total
total
BOMB CALORIMETER
ASTM
116C
117C
CAT NO
1147B
1147C
18.9 to 25.1OC
23.9 to 30.1OC
0.01
0.01
609mm
609mm
total
total
KINEMATIC VISCOSITY
ASTM
118F
118C
CAT NO
1096P
1096W
APPLICATION
Kinematic viscosity
Kinematic viscosity
83.5 to 88.5OF
28.6 to 31.4OC
0.1
0.05
305mm
305mm
COOLANT FREEZING POINT
ASTM
119C
119F
CAT NO
1096X
1097X
APPLICATION
Coolant Frz. Pt.
Coolant Frz. Pt.
TEMP RANGE
-35.5 to -30OC
-37 to -22OF
0.05
0.1
305mm
3O5mm
1096N
total
total
1268
total
total
Page 17
KINEMATIC VISCOSITY
ASTM
120C
121C
CAT NO
1096Y
1096Z
APPLICATION
Kinematic Viscosity
Kinematic viscosity
38.5 to 41.5OC
98.5 to 101.5OC
TEMP RANGE
0.05
0.05
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
305mm
305mm
total
total
BROOKFIELD VISCOSITY
ASTM
122C
123C
124C
125C
CAT NO
1098A
1098B
1098C
10980
APPLICATION
Brookfield viscosity
Brookfield Viscosity
Brookfield Viscosity
Brookfield Viscosity
-45 to -35OC
-35 to -25OC
-25 to -15OC
-15 to -5OC
0.1
0.1
0.1
0.1
300mm
300mm
300mm
300mm
total
total
total
total
KINEMATIC VISCOSITY
ASTM
126C
126F
127C
128C
128F
129C
129F
132C
CAT NO
1098E
1098F
1098G
1098H
10981
1098J
1098K
1098L
APPLICATION
Kinematic Viscosity
Kinematic Viscosity
Kinematic viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic Viscosity
Kinematic viscosity
Kinematic Viscosity
-27.4 to -24.6OC
-17.5 to -12.5OF
-21.4 to -18.6OC
-1.4 to +1.4OC
29.5 to 34.5OF
91.6 to 94.4OC
197.5 to 202.5OF
148.6 to 151.4OC
0.05
0.1
0.05
0.05
0.1
0.05
0.1
0.05
305mm
305mm
305mm
305mm
305mm
305mm
305mm
305mm
total
total
total
total
total
total
total
total
TANK GAUGING – REFILL
ASTM
130C
130F
CAT NO
1271
1261
APPLICATION
Tank Gauging, Refill
Tank Gauging, Refill
-7 to 110OC
20 to 220OF
0.5
1
305mm
305mm
total
total
PRECISION-PARTIAL IMMERSION
ASTM
133C
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
CAT NO
APPLICATION
TEMP RANGE
DIV
LENGTH
IMMERSION
1099 Precision-Partial Immersion
-38 to +2OC
0.1
379mm
76mm
SLUDGE
ASTM
134C
1100
Sludge
144 to 156OC
0.2
270mm
100mm
1271
Page <#>
ASTM THERMOMETERS
LOW TOXIC NON-MERCURY
DENSITY - WIDE RANGE (GRAVITY)
ASTM
S12C-03
S12F-03
CAT NO
1042-S
1040-S
APPLICATION
TEMP RANGE
APPLICATION
TEMP RANGE
19 to 35OC
66 to 95OF
0.02
0.05
APPLICATION
Density Wide Range
Density Wide Range
DIV
LENGTH
IMMERSION
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
TEMP RANGE
DIV
LENGTH
IMMERSION
DIV
LENGTH
IMMERSION
-20 to 102OC
-5 to 215OF
0.2
0.5
435mm
435mm
total
total
BOMB CALORIMETER
ASTM
S56C-03
S56F-03
CAT NO
1147-S
1147A-S
Bomb Calorimeter
Bomb Calorimeter
610mm
610mm
total
total
TANK GAUGING
ASTM
S59C-03
S59F-03
CAT NO
1253-S
1256-S
Tank
Tank
-18 to 82OC
0 to 180OF
0.5
1
300mm
300mm
total
total
PRECISION-TOTAL IMMERSION
ASTM
S62C-03
S62F-03
S63C-03
S63F-03
S64C-03
S64F-03
S65C-03
S65F-03
S66C-03
S66F-03
S67C-03
S67F-03
CAT NO
1300-S
1320-S
1302-S
1322-S
1304-S
1324-S
1306-S
1326-S
1308-S
1328-S
1310-S
1330-S
APPLICATION
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
-38 to 2OC
-36 to 35OF
-8 to 32OC
18 to 89OF
25 to 55OC
77 to 131OF
50 to 80OC
122 to 176OF
75 to 105OC
167 to 221OF
95 to 155OC
203 to 311OF
0.1
0.2
0.1
0.2
0.1
0.2
0.1
0.2
0.1
0.2
0.2
0.5
401mm
401mm
401mm
401mm
401mm
401mm
401mm
401mm
401mm
401mm
401mm
401mm
total
total
total
total
total
total
total
total
total
total
total
total
SOLIDIFICATION POINT
ASTM
S91C-03
CAT NO
1224-S
APPLICATION
Solidification Point
20 to 50OC
0.1
390mm
76mm
KINEMATIC VISCOSITY
ASTM
S120C-03
CAT NO
1096Y-S
APPLICATION
Kinematic Viscosity
TEMP RANGE
38.6 to 41.1OC
0.05
300mm
total
1042-S
Page 19
ASTM CERTIFIED MASTER
THERMOMETERS
Page 21
PARTIAL IMMERSION
ASTM
1C
1F
2C
2F
3C
3F
IP
CAT NO
CERTIFICATION TEST POINTS
62C
62F
73C
1102-C
1104-C
1106-C
1108-C
1110-C
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
test
test
test
test
test
points
points
points
points
points
of
of
of
of
of
-20, 0, 50, 100, 150C
0, 32, 122, 212, 302F
0, 75, 150, 225, 300C
32, 150, 300, 450, 580F
0, 100, 200, 300, 370C
73F
1112-C
Certified @ ASTM specified test points of 32, 200, 370, 540, 700F
ACID HEAT
ASTM
4C
4F
IP
CAT NO
1002-C
1000-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 50, 100C
Certified @ ASTM specified test points of 32, 122, 215F
CLOUD AND POUR - LOW AND HIGH
ASTM
5C
5F
6C
1C
1F
2C
IP
CAT NO
1006-C
1004-C
1010-C
Certified @ ASTM specified test points of -30, 0, 50C
Certified @ ASTM specified test points of -30, 32, 120C
Certified @ ASTM specified test points of -70, 35, 0, 20C
CERTIFICATION TEST POINTS
6F
2F
1008-C
Certified @ ASTM specified test points of -94, -30, 32, 70F
DISTILLATION - LOW AND HIGH
ASTM
7C
7F
8C
IP
5C
CAT NO
6C
8F
CERTIFICATION TEST POINTS
1014-C
1012-C
1018-C
Certified @ ASTM specified test points of 0, 50, 100, 150, 200, 250, 300C
Certified @ ASTM specified test points of 32, 100, 200, 300, 400, 500, 570F
Certified @ ASTM specified test points of 0, 100, 200, 300, 370C
1016-C
Certified @ ASTM specified test points of 32, 200, 370, 540, 700F
PENSKY-MARTENS - LOW AND HIGH
ASTM
9C
9F
10C
15C
15F
16C
IP
CAT NO
1022-C
1020-C
1026-C
Certified @ ASTM specified test points of 0, 35, 70, 150C
Certified @ ASTM specified test points of 32, 100, 160, 220F
Certified @ ASTM specified test points of 100, 200, 300, 370C
CERTIFICATION TEST POINTS
10F
16F
1024-C
Certified @ ASTM specified test points of 212, 390, 570, 700F
OPEN FLASH
ASTM
11C
11F
IP
28C
28F
CAT NO
1038-C
1036-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 100, 200, 300, 370C
Certified @ ASTM specified test points of 32, 200, 370, 540, 700F
DENSITY - WIDE RANGE (GRAVITY)
ASTM
12C
12F
IP
64C
64F
CAT NO
1042-C
1040-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -20, -10, 0, 10, 20, 30, 40, 50C
Certified @ ASTM specified test points of -5, 15, 32, 60, 85F
LOSS ON HEAT
ASTM
13C
IP
47C
CAT NO
1048A-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 155, 163, 170C
PARAFFIN WAX MELTING POINT
ASTM
14C
14F
IP
17C
17F
CAT NO
1051-C
1050-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 40, 50, 60, 70, 80C
Certified @ ASTM specified test points of 100, 120, 140, 160, 180F
1042-C
SOFTENING POINT
ASTM
15C
15F
16C
16F
IP
60C
61C
CAT NO
1056-C
1054-C
1060-C
1058-C
1010-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
@
@
@
@
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
test
test
test
test
points
points
points
points
of
of
of
of
0, 20, 40, 60, 80C
32, 70, 100, 140, 180F
30, 60, 90, 120, 150, 180, 200C
90, 140, 190, 240, 290, 340, 390F
ASTM CERTIFIED MASTER
SAYBOLT VISCOSITY
ASTM
17C
17F
18C
18F
19C
19F
20C
20F
21C
21F
22C
22F
IP
23C
23F
24C
24F
CAT NO
1085-C
1066-C
1086-C
1067-C
1087-C
1068-C
1088-C
1069-C
1089-C
1075-C
1090-C
1076-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
test
test
test
test
test
test
points
points
points
points
points
points
points
points
points
points
points
points
of
of
of
of
of
of
of
of
of
of
of
of
21, 25C
70, 77F
38, 41C
100, 107F
50, 54C
122, 130F
60, 64C
140, 147F
82, 86C
180, 187F
99, 102C
210, 212C
ENGLER VISCOSITY
ASTM
23C
24C
25C
IP
CAT NO
1092-C
1093-C
1094-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 20, 25C
Certified @ ASTM specified test points of 40, 50C
Certified @ ASTM specified test points of 95, 100C
STABILITY TEST OF SOLUBLE NITROCELLULOSE
ASTM
26C
IP
CAT NO
1120-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 130, 135, 140C
TURPENTINE DISTILLATION
ASTM
27C
IP
CAT NO
1122-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 155, 165, 175C
KINEMATIC VISCOSITY
ASTM
28C
28F
29C
29F
30F
IP
31C
31F
34C
34F
32F
CAT NO
CERTIFICATION TEST POINTS
1097G-C
1096G-C
1097I-C
1096I-C
1096M-C
Certified
Certified
Certified
Certified
Certified
CAT NO
CERTIFICATION TEST POINTS
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
test
test
test
test
test
points
points
points
points
points
of
of
of
of
of
0, 37.8, 39C
32, 100, 102F
0, 54.4, 55C
32, 130, 132F
32, 210, 212F
REID VAPOR
ASTM
31F
IP
1003-C
Certified @ ASTM specified test points of -20, 32, 100F
ANILINE POINT
ASTM
33C
33F
34C
34F
35C
35F
IP
20F
21F
59F
CAT NO
1126-C
1127-C
1128-C
1129-C
1130-C
1131-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
points
points
points
points
points
points
of
of
of
of
of
of
-35, -20, 0, 20, 40C
-31, -4, 32, 68, 104F
25, 45, 65, 85, 100C
77, 113, 149, 185, 212F
100, 120, 140, 160, 170C
212, 250, 285, 320, 338F
TITER TEST
ASTM
36C
IP
CAT NO
1272-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 15, 30, 45, 65C
SOLVENTS DISTILLATION
ASTM
37C
38C
39C
40C
41C
42C
IP
77C
78C
79C
80C
81C
82C
CAT NO
1132-C
1134-C
1136-C
1138-C
1140-C
1142-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
points
points
points
points
points
points
of
of
of
of
of
of
15, 30, 50C
25, 40, 55, 75C
50, 65, 80, 100C
75, 90, 105, 125C
100, 115, 130, 150C
100, 150, 200, 250C
1096E-C
1056-C
1067-C
Page 23
KINEMATIC VISCOSITY
ASTM
43C
43F
44C
44F
45C
45F
46C
46F
47C
47F
48C
48F
IP
65C
65F
29C
29F
30C
30F
66C
66F
35C
35F
90C
90F
CAT NO
1097B-C
1096B-C
1096Q-C
1096E-C
1096R-C
1096F-C
1096S-C
1096H-C
1096T-C
1096K-C
1097L-C
1096L-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
test
test
test
test
test
test
points
points
points
points
points
points
points
points
points
points
points
points
of
of
of
of
of
of
of
of
of
of
of
of
-50, -45, -40, -35, 0C
-60, -50, -40, -30, +32F
0, 20, 21C
32, 68, 70F
0, 25, 26C
32, 77, 79F
0, 50, 51C
32, 122, 124F
0, 60, 61C
32, 140, 142F
0, 82.2, 83C
32, 180, 182F
STORMER VISCOSITY
ASTM
49C
IP
CAT NO
1095-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 20, 35, 50, 70C
GAS CALORIMETER
ASTM
50F
51F
IP
CAT NO
1144-C
1146-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 55, 60, 70, 75, 80, 85, 90, 85, 100F
Certified @ ASTM specified test points of 70, 75, 80, 85, 90, 95, 100, 105, 110, 115F
BUTADINE BOILING POINT
ASTM
52C
IP
CAT NO
1148-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -10, 0, 5C
BENZENE FREEZING POINT
ASTM
53C
IP
CAT NO
1148C-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 5, 10C
CONGEALING POINT
ASTM
54C
54F
IP
O
18 OC
18 F
CAT NO
1048-C
1047-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 20, 50, 75, 100C
Certified @ ASTM specified test points of 70, 120, 170, 210F
BOMB CALORIMETER
ASTM
56C
56F
IP
CAT NO
1147-C
1147A-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 19, 21, 23, 25, 27, 29, 31, 33, 35C
Certified @ ASTM specified test points of 66, 70, 74, 78, 82, 88, 92, 95F
TAG CLOSED TESTER
ASTM
57C
57F
IP
CAT NO
1034-C
1032-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -20, 25, 50C
Certified @ ASTM specified test points of -3, 32, 77, 122F
1272-C
1082-C
ASTM CERTIFIED MASTER
TANK GAUGING – REFILL
ASTM
58C
58F
59
59F
60C
60F
IP
CAT NO
CERTIFICATION TEST POINTS
1248-C
Certified @ ASTM specified test points of -30, 0, 25, 45C
1252-C
Certified @ ASTM specified test points of -20, 32, 80, 120F
1253-C
Certified @ ASTM specified test points of 0, 25, 55, 80C
1256-C
Certified @ ASTM specified test points of 32, 80, 180, 180F
1257-C
Certified @ ASTM specified test points of 100, 175, 255C
1260-C
Certified @ ASTM specified test points of 212, 350, 490F
(FOR COMPLETE UNITS AND CASES, SEE GAUGING SECTION, PAGE #)
ANY OF THE ABOVE MAY BE FURNISHED WITH RED READING LENS GLASS AT ADDITIONAL COST. ADD
SUFFIX“RRL” TO CATALOG NUMBER.
PETROLATUM MELT POINT
ASTM
61C
61F
IP
16C
CAT NO
1053-C
1052-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 40, 60, 80, 100, 120C
Certified @ ASTM specified test points of 100, 150, 200, 250F
ASTM PRECISION SERIES
PRIMARY REFERENCE STANDARDS
CERTIFIED TRACEABLE TO NIST
1256-C
• THERMOMETERS AS ON FACING PAGE, CERTIFIED NIST (FORMERLY NBA) TRACEABLE AT THE ICE POINT AND
FOUR POINTSON THE MAIN SCALE, AS SPECIFIED BY ASTM E-1. WITH CERTIFICATE OF CALIBRATION AS SHOWN.
• IDEAL FOR USE AS PRIMARY LABORATORY REFERENCE STANDARDS.
ASTM
62C
63C
64C
65C
66C
67C
68C
69C
70C
IP
2C
61C
12C
43C
46C
72C
73C
74C
CAT NO
1300C
1302C
1304C
1306C
1308C
1310C
1312C
1314C
1316C
TEMP RANGE
-38 to 2OC
-8 to 32OC
25 to 55OC
50 to 80OC
75 to 105OC
95 to 155OC
145 to 205OC
195 to 305OC
295 to 405OC
62F
63F
64F
65F
66F
67F
68F
69F
70F
2F
1320C
1322C
1324C
1326C
1328C
1330C
1332C
1334C
1336C
-36 to 35OF
18 to 89OF
77 to 131OF
122 to 176OF
167 to 221OF
203 to 311OF
293 to 401OF
383 to 581OF
563 to 761OF
12F
43F
46F
72F
73F
74F
CORRECTIONS GIVEN AT
-37
-30
-20
-7
0
10
0
25
35
0
50
60
0
75
85
0
100
110
0
150
170
0
200
235
0
300
335
-35
20
32
32
32
32
32
32
32
-15
32
80
125
168
205
300
400
570
0
50
95
145
185
240
340
460
640
EACH TEMPERATURE
-10
20
45
70
95
130
190
270
370
15
70
115
160
200
275
370
520
700
0C
30C
55C
80C
105C
150C
205C
305C
400C
32
88
130
175
220
310
400
580
760
AVAILABLE INDIVIDUALLY OR IN SETS.
COMPLETE SET OF FAHRENHEIT THERMOMETERS, ASTM NUMBERS
62F THROUGH 70F, EACH FURNISHED WITH NIST TRACEABLE
CERTIFICATE OF CALIBRATION IN A VELVET LINED PROTECTIVE CASE.
CATALOG NO. 1298-C
COMPLETE SET OF CELSIUS THERMOMETERS, ASTM NUMBERS
62C THROUGH 70C, EACH FURNISHED WITH NIST TRACEABLE
CERTIFICATE OF CALIBRATION IN A VELVET LINED PROTECTIVE CASE.
CATALOG NO. 1296-C
Page 25
OIL IN WAX
ASTM
71C
71F
IP
CAT NO
1293A-C
1293-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -35, -18, 0, 20C
Certified @ ASTM specified test points of -30, 0, 32, 70F
KINEMATIC VISCOSITY
ASTM
72C
72F
73C
73F
74C
74F
IP
CAT NO
1097A-C
1096A-C
1096U-C
1096C-C
109Th-C
10960-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
points
points
points
points
points
points
of
of
of
of
of
of
-19, -17.8, 0C
-2, 0, 32F
-41, 0C
-42, -41, 32F
-55, -55.9, 0C
-67, -65, 32F
COOLANT FREEZING POINT
ASTM
75F
76F
IP
CAT NO
1200-C
1202-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -35, 0, 32F
Certified @ ASTM specified test points of -65, -30, 32F
SAYBOLT VISCOSITY
ASTM
77F
78F
79F
80F
81F
IP
CAT NO
1077-C
1079-C
1080-C
1082-C
1084-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
test
test
test
test
test
points
points
points
points
points
260F
310F
360F
410F
460F
of
of
of
of
of
250,
300,
350,
400,
450,
of
of
of
of
of
of
of
of
of
of
of
of
32, 100, 200F
0, 50, 100C
85, 135F
25, 70C
100, 150F
30, 80C
150, 250F
50, 150C
225, 325F
100, 175C
300, 400F
160, 200C
FUEL RATING
ASTM
82F
82C
83F
83C
84F
84C
85F
85C
86F
86C
87F
87C
IP
CAT NO
1204-C
1205-C
1206-C
1207-C
1208-C
1209-C
1210-C
1211-C
1212-C
1213-C
1214-C
1215-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
test
test
test
test
test
test
points
points
points
points
points
points
points
points
points
points
points
points
VEGETABLE OIL FLASH
ASTM
88C
88F
IP
CAT NO
1216-C
1218-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 40, 100, 150, 200C
Certified @ ASTM specified test points of 110, 212, 300, 392F
1214-C
SOLIDIFICATION POINT
ASTM
89C
90C
91C
92C
93C
94C
95C
96C
IP
CAT NO
1220-C
1222-C
1224-C
1226-C
1228-C
1230-C
1232-C
1234-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
test
test
points
points
points
points
points
points
points
points
of
of
of
of
of
of
of
of
-20, -10, 0, 10C
0, 10, 20, 30C
20, 30, 40, 50C
40, 50, 60, 70C
60, 70, 80, 90C
80, 90, 100, 110C
100, 110, 120, 130C
120, 130, 140, 150C
of
of
of
of
-50, 0, 20, 45C
0, 32, 70, 110F
20, 40, 60, 80C
60, 100, 140, 180F
TANK GAUGING – REFILL
ASTM
97C
97F
98C
98F
IP
CAT NO
1244-C
1262-C
1246-C
1264-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
@
@
@
@
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
test
test
test
test
points
points
points
points
1220-C
ASTM CERTIFIED MASTER
WEATHERING TEST
ASTM
99F
99C
IP
CAT NO
1278-C
1279-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -50, -25, 0, 32F
Certified @ ASTM specified test points of -46, -32, -18, 0C
SOLVENTS DISTILLATION
ASTM
102C
103C
104C
105C
106C
107C
IP
CAT NO
1266-C
1268-C
1270-C
1273-C
1274-C
1276-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
points
points
points
points
points
points
of
of
of
of
of
of
125,
150,
175,
200,
225,
250,
140,
165,
190,
215,
240,
265,
155,
180,
205,
230,
255,
280,
175C
200C
225C
250C
275C
300C
SAYBOLT VISCOSITY
ASTM
108F
109F
IP
CAT NO
1091A-C
1091B-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 275, 285F
Certified @ ASTM specified test points of 325, 335F
KINEMATIC VISCOSITY
ASTM
110C
110F
IP
CAT NO
1096V-C
1096N-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 135, 136C
Certified @ ASTM specified test points of 32, 375, 377F
TAR ACID DISTILLATION
ASTM
111C
IP
CAT NO
1284-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 170, 200, 250C
SOLIDIFICATION POINT OF BENZENE
ASTM
112C
IP
CAT NO
1286-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 4, 5, 6C
BITUMINOUS MATERIALS SOFTENING POINT
ASTM
113C
IP
CAT NO
1289-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 50, 100, 150, 175C
AVIATION FUELS FREEZING POINT
ASTM
114C
114F
IP
CAT NO
1290-C
1291-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -75, -60, -40, 0C
Certified @ ASTM specified test points of -103, -76, -40, 32F
BOMB CALORIMETER
ASTM
116C
117C
IP
CAT NO
1147B-C
1147C-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 19, 20, 21, 22, 23, 24, 25C
Certified @ ASTM specified test points of 24, 25, 26, 27, 28, 29, 30C
KINEMATIC VISCOSITY
ASTM
118F
118C
IP
CAT NO
1096P--C
1096W-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 32, 86, 88F
Certified @ ASTM specified test points of 0, 30, 31C
1290-C
COOLANT FREEZING POINT
ASTM
119C
119F
IP
CAT NO
1096X-C
1097X-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -38, -30, 0C
Certified @ ASTM specified test points of -36, -22, +32F
1268-C
KINEMATIC VISCOSITY
ASTM
120C
121C
IP
CAT NO
1096Y-C
1096Z-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 40, 41C
Certified @ ASTM specified test points of 0, 100, 101C
Page 27
BROOKFIELD VISCOSITY
ASTM
122C
123C
124C
125C
IP
CAT NO
1098A-C
1098B-C
1098C-C
10980-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
@
@
@
@
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
test
test
test
test
points
points
points
points
-40,
-30,
-20,
-10,
-35C
-25C
-15C
-5C
of
of
of
of
-45,
-35,
-25,
-15,
of
of
of
of
of
of
of
of
-27, -26.1, 0C
-17, -15, +32F
-21, -20, 0C
0, 1C
32, 34F
0, 93.3, 94C
32, 200, 202F
0, 150, 151C
KINEMATIC VISCOSITY
ASTM
126C
126F
127C
128C
128F
129C
129F
132C
IP
CAT NO
1098E-C
1098F-C
1098G-C
1098H-C
10981-C
1098J-C
1098K-C
1098L -C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
test
test
points
points
points
points
points
points
points
points
TANK GAUGING – REFILL
ASTM
130C
130F
IP
CAT NO
1271-C
1261-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 35, 70, 105C
Certified @ ASTM specified test points of 32, 100, 160, 220F
PRECISION-PARTIAL IMMERSION
ASTM
133C
IP
CAT NO
IP
CAT NO
1099-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -36, -30, -24, -18, -12, -6, 0C
SLUDGE
ASTM
134C
1100-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 145, 150, 155C
1271-C
ASTM CERTIFIED MASTER
LOW TOXIC NON-MERCURY
DENSITY - WIDE RANGE (GRAVITY)
ASTM
S12C-03
S12F-03
IP
CAT NO
1042-S-C
1040-S-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of -20, -10, 0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100C
Certified @ ASTM specified test points of -5, 15, 32, 60, 85, 110, 135, 160, 185, 210F
BOMB CALORIMETER
ASTM
S56C-03
S56F-03
IP
CAT NO
1147-S-C
1147A-S-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 19, 21, 23, 25, 27, 29, 31, 33, 35C
Certified @ ASTM specified test points of 65, 69, 73, 77, 81, 85, 89, 93, 95F
TANK GAUGING
ASTM
S59C-03
S59F-03
IP
CAT NO
1253-S-C
1256-S-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 25, 55, 80C
Certified @ ASTM specified test points of 32, 80, 130, 180F
PRECISION-TOTAL IMMERSION
ASTM
S62C-03
S62F-03
S63C-03
S63F-03
S64C-03
S64F-03
S65C-03
S65F-03
S66C-03
S66F-03
S67C-03
S67F-03
IP
CAT NO
1300-S-C
1320-S-C
1302-S-C
1322-S-C
1304-S-C
1324-S-C
1306-S-C
1326-S-C
1308-S-C
1328-S-C
1310-S-C
1330-S-C
CERTIFICATION TEST POINTS
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
Certified
@
@
@
@
@
@
@
@
@
@
@
@
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
ASTM
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
specified
test
test
test
test
test
test
test
test
test
test
test
test
points
points
points
points
points
points
points
points
points
points
points
points
of
of
of
of
of
of
of
of
of
of
of
of
-37, -30, -20, -10, 0C
-35, -15, 0, 15, 32F
-7, 0, 10, 20, 30C
20, 32, 50, 70, 88F
0, 25, 35, 45, 55C
32, 80, 95, 115, 130F
0, 50, 60, 70, 80C
32, 125, 145, 160, 175F
0, 75, 85, 95, 105C
32, 168, 185, 200, 220F
0, 100, 110, 130, 150C
32, 205, 240, 275, 310F
SOLIDIFICATION POINT
ASTM
S91C-03
IP
CAT NO
1224-S-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 20, 30, 40, 50C
KINEMATIC VISCOSITY
ASTM
S120C-03
IP
CAT NO
1096Y-S-C
CERTIFICATION TEST POINTS
Certified @ ASTM specified test points of 0, 40, 41C
n
1042-S-C
1714
Page 29
FRACTIONAL DEGREE PRECISION
LABORATORY THERMOMETERS
Page 31
KESSLER Precision Laboratory Thermometers are supplied in yellow back glass with PERMETCH Brand permanent pigmentation of graduations. All of these instruments are aged and annealed for extended accurate service
life, and are suitable for certification.
EXTREME PRECISION THERMOMETERS
CELSIUS RANGES - (MERCURY
CAT NO
2100
2102
2104
2106
+
+
+
+
TYPE
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
CELSIUS RANGES - (MERCURY
CAT NO
2100-3
2102-3
2104-3
2106-3
+
+
+
+
TYPE
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
FILLED)
-1 to 51OC
-1 to 101OC
-1 to 101OC
-1 to 201OC
FILLED)
2118
2120
2122
2124
+
+
+
+
TYPE
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
-1 to 51OC
-1 to 101OC
-1 to 101OC
-1 to 201OC
FAHRENHEIT RANGES- (MERCURY
CAT NO
2118-3
2120-3
2122-3
2124-3
+
+
+
+
TYPE
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
FILLED)
TEMP RANGE
+30
+30
+30
+30
to
to
to
to
DIV
0.1
0.2
0.1
0.2
124 F
124OF
220OF
394OF
O
DIV
0.1
0.2
0.1
0.2
TOTAL
0.2
0.1
0.2
0.5
FILLED)
PARTIAL
DIV
to
to
to
to
IMMERSION
LENGTH
IMMERSION
457mm
457mm
610mm
610mm
Total
Total
Total
Total
124 F
124OF
220OF
394OF
O
457mm
457mm
610mm
610mm
76mm
76mm
76mm
76mm
IMMERSION
DIV
TEMP RANGE
+30
+30
+30
+30
LENGTH
PARTIAL IMMERSION
TEMP RANGE
FAHRENHEIT RANGES- (MERCURY
CAT NO
TOTAL IMMERSION
TEMP RANGE
0.2
0.1
0.2
0.5
LENGTH
457mm
610mm
610mm
610mm
IMMERSION
Total
Total
Total
Total
IMMERSION
LENGTH
457mm
610mm
610mm
610mm
IMMERSION
3”
3”
3”
3”
+ ITEMS MARKED WITH + AVAILABLE IMMEDIATELY FROM STOCK WITH NIST TRACEABLE CERTIFICATE OF CALIBRATION.
ADD “-C” TO CAT. NO.
EXTREME PRECISION THERMOMETERS (NON-MERCURIAL)
CELSIUS RANGES - TOTAL IMMERSION
CAT NO
2100-RL
2102-RL
2104-RL
2106-RL
TYPE
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
TEMP RANGE
-1 to 51OC
-1 to 101OC
-1 to 101OC
-1 to 201OC
DIV
LENGTH
IMMERSION
DIV
LENGTH
IMMERSION
0.1
0.2
0.1
0.2
457mm
457mm
610mm
610mm
Total
Total
Total
Total
CELSIUS RANGES - PARTIAL IMMERSION
CAT NO
2100-3RL
2102-3RL
2104-3RL
2106-3RL
TYPE
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
TEMP RANGE
-1 to 51OC
-1 to 101OC
-1 to 101OC
-1 to 201OC
0.1
0.2
0.1
0.2
457mm
457mm
610mm
610mm
76mm
76mm
76mm
76mm
2100
2100-RL
FRACTIONAL DEGREE PRECISION THERMOMETERS
EXTREME PRECISION THERMOMETERS (NON-MERCURIAL)
FAHRENHEIT RANGES - TOTAL
CAT NO
TYPE
2118-RL
2120-RL
2122-RL
2124-RL
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
IMMERSION
TEMP RANGE
+30
+30
+30
+30
FAHRENHEIT RANGES - PARTIAL
CAT NO
TYPE
2118-3RL
2120-3RL
2122-3RL
2124-3RL
Extreme
Extreme
Extreme
Extreme
Precision
Precision
Precision
Precision
to
to
to
to
124OF
124OF
220OF
394OF
DIV
LENGTH
IMMERSION
DIV
LENGTH
IMMERSION
0.2
0.1
0.2
0.5
457mm
610mm
610mm
610mm
Total
Total
Total
Total
IMMERSION
TEMP RANGE
+30
+30
+30
+30
to
to
to
to
124OF
124OF
220OF
394OF
0.2
0.1
0.2
0.5
457mm
610mm
610mm
610mm
3”
3”
3”
3”
+ ITEMS MARKED WITH + AVAILABLE IMMEDIATELY FROM STOCK WITH NIST TRACEABLE CERTIFICATE OF CALIBRATION.
ADD “-C” TO CAT. NO.
MANUFACTURING CHEMISTS ASSOCIATION “R” SERIES
SEQUENTIAL CELSIUS RANGES FOR GENERAL RESEARCH AND TESTING PROCEDURES.
CAT NO
TYPE
2150
2152
2154
2156
Precision
Precision
Precision
Precision
TEMP RANGE
M.C.A.R-1
M.C.A.R-2
M.C.A.R-3
M.C.A.R-4
DIV
-36 to 54OC
-10 to 80OC
70 to 160OC
140 to 230OC
LENGTH
IMMERSION
LENGTH
IMMERSION
0.2
0.2
0.2
0.2
406mm
406mm
406mm
406mm
76mm
76mm
76mm
76mm
CELSIUS - PRECISION TEST - PARTIAL IMMERSION
THIS THERMOMETER SERIES HAS BEEN DESIGNED IN CONJUNCTION WITH THE THERMOMETER COMMITTEE OF
ONE OF THE CHEMICAL INDUSTRY’S LARGEST COMPANIES TO SATISFY THEIR NATIONWIDE REQUIREMENTS FOR
CLOSE, ACCURATE READINGS IN BOTH LABORATORY AND PRODUCTION WORK.
CAT NO
TYPE
2200
2202
2204
2206
2208
2210
2212
2214
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
TEMP RANGE
JL-1
JL-2
JL-3
JL-4
JL-5
JL-6
JL-7
JL-8
DIV
-36 to 30OC
-5 to 30OC
25 to 60OC
55 to 90OC
85 to 120OC
115 to 185OC
180 to 250OC
245 to 420OC
0.2
0.1
0.1
0.1
0.1
0.2
0.2
0.5
406mm
406mm
406mm
406mm
406mm
406mm
406mm
406mm
76mm
76mm
76mm
76mm
76mm
76mm
76mm
76mm
FAHRENHEIT - PRECISION TEST - PARTIAL IMMERSION
DESIGNED AS THE FAHRENHEIT COUNTERPARTS OF OUR POPULAR 2200 SERIES (ABOVE), THIS SERIES ALLOWS CLOSE, ACCURATE READINGS IN BOTH LABORATORY AND PRODUCTION WORK.
CAT NO
2300
2302
2304
2306
2308
2310
2312
2314
2216
2316
TYPE
Precision
Precision
Precision
Precision
Precision
Precision
Precision
Precision
TEMP RANGE
-36 to 85OF
23 to 86OF
77 to 140OF
131 to 194OF
185 to 248OF
239 to 365OOF
356 to 482OF
473 to 788OF
DIV
0.5
0.2
0.2
0.2
0.2
0.5
0.5
1.0
COMPLETE SET OF THE CELSIUS ABOVE THERMOMETERS IN VELVET-LINED CASE
COMPLETE SET OF THE FAHRENHEIT ABOVE THERMOMETERS IN VELVET-LINED CASE
LENGTH
406m
406mm
406mm
406mm
406mm
406mm
406mm
406mm
IMMERSION
3”
3”
3”
3”
3”
3”
3”
3”
2214
2302
Page 33
LABORATORY THERMOMETERS
PRECISION GRADE
Page 35
Manufactured for general testing and laboratory procedures where an ASTM thermometer is not
specified. Supplied with PERMETCH brand permanent pigmentation of graduations. Manufactured
with greatest ease for extended and long service life. All instruments of this series comply with
NIST Special Publication 250-23 and are eligible for certification.
MERCURY THERMOMETERS (YELLOW
GLASS)
CELSIUS RANGES
TOTAL IMMERSION
RANGE
DIV
CAT NO.
2048T
2050T
2052T
-35to 50OC
-20 to 110OC
-20 to 150OC
1
1
1
2054T
2056T
2058T
2060T
2062T
2064T*
-10
-10
-10
-10
-10
-10
1
1
1
1
1
2
to
to
to
to
to
to
210OC
250OC
310OC
360OC
400OC
510OC
LENGTH
305mm
305mm
305mm
76MM IMMERSION
CAT NO.
RANGE
DIV
LENGTH
3” IMMERSION
CAT NO.
RANGE
DIV
LENGTH
2048
2050
2052
2053
2054
2056
2058
2060
2062
2064*
381mm
381mm
381mm
406mm
406mm
406mm
-35 to 50OC
-20 to 110OC
-20 to 150OC
-5 to 150OC 0
-10 to 210OC
-10 to 250OC
-10 to 310OC
-10 to 360OC
-10 to 400OC
-10 to 510OC
1
1
1
.5
1
1
1
1
1
2
305mm
305mm
305mm
381mm
381mm
381mm
381mm
406mm
406mm
406mm
FAHRENHEIT RANGES
TOTAL IMMERSION
RANGE
DIV
CAT NO.
2000T
2001T
2002T
2003T
2004T
2005T
2006T
2007T
2008T
2010T
2012T
2016T
2022T*
0 to 120OF
-30 to 120OF
0 to 150OF
-4 to 230OF
30 to 220OF
0 to 300OF
30 to 300OF
0 to 400OF
30 to 400OF
30 to 500OF
30 to 600OF
30 to 750OF
30 to 1000OF
DUAL SCALE (CELSIUS
CAT NO.
3050T
3052T
3056T
3060T
AND
LENGTH
1
1
1
2
1
2
1
2
2
2
2
2
5
12”
12”
12”
12”
15”
12”
15”
12”
15”
15”
15”
16”
16”
2000
2001
2002T
2003T
2004
2005
2006
2007
2008
2010
2012
2016
2022
0 to 120OF
-30 to 120OF
0 to 150OF
-4 to 230OF
30 to 220OF
0 to 300OF
30 to 300OF
0 to 400OF
30 to 400OF
30 to 500OF
30 to 600O F
30 to 750OF
30 to 1000OF
1
1
1
2
1
2
1
2
2
2
2
2
5
12”
12”
12”
12”
15”
12”
15”
12”
15”
15”
15”
16”
16”
FAHRENHEIT)
TOTAL IMMERSION
RANGE
DIV
-20/110OC & 0/230OF
-20/150OC & 0/300OF
-10/260OC & 30/500OF
-10/360OC & 30/700OF
1C
1C
1C
1C
2F
2F
2F
2F
LENGTH
CAT NO.
12”
12”
15”
16”
3062T
-10/400OC & 30/750OF
1C 2F
16”
* FABRICATED OF WHITE BACK BOROSILICATE GLASS FOR ACCURACY AND STABILITY.
76MM IMMERSION
RANGE
DIV
3050
3052
3056
3060
-20/110OC & 0/230OF
-20/150OC & 0/300OF
-10/260OC & 30/500OF
-10/360OC & 30/700OF
1C
1C
1C
1C
3062
-10/400OC & 30/750OF
1C 2F
LENGTH
2F
2F
2F
2F
12”
12”
15”
16”
16”
MERCURY FILLED TEFLON ENCAPSULATED*
AN ACCURATE LIQUID-IN-GLASS THERMOMETER, HERMETICALLY SEALED WITHIN A CAPSULE OF TEFLON TUBING.
R E S I S T S
B R E A K A G E
–
I
M P E R V I O U S
T O
A C I D
-C
O N T A M I N A T I O N
F R E E
.
CELSIUS RANGES
CAT NO
2026T
2028T
2030T
2031T
TOTAL IMMERSION
TEMP RANGE
DIV
-20 to 10OC
-20 to 150OC
-10 to 210OC
-10 to 250OC
1
1
1
1
LENGTH
305mm
305mm
381mm
381mm
76MM IMMERSION
CAT NO TEMP RANGE DIV
2026
2028
2030
2031
-20
-20
-10
-10
to
to
to
to
110OC
150OC
210OC
250OC
* Most thermometers in this catalog, including ASTM thermometers, with top ranges not exceeding approximately
260C (or 500F) may be Teflon encapsulated. Please consult factory for specific details.
1
1
1
1
LENGTH
305mm
305mm
381mm
381mm
2056
LABORATORY PRECISION GRADE
MERCURY FILLED TEFLON ENCAPSULATED
(CONTINUED)
FAHRENHEIT RANGES
CAT NO
TOTAL IMMERSION
TEMP RANGE
DIV
2032T
2034T
2036T
2037T
-4 to 230OF
0 to 300OF
30 to 400OF
30 to 500OF
2
2
2
2
LENGTH
12”
12”
15”
15”
CAT NO
2001-TE
2032
2034
2036
2037
76MM IMMERSION
TEMP RANGE
DIV LENGTH
-30 to 120OF
-4 to 230OF2
0 to 300OF2
30 to 400OF
30 to 500OF
1
1
1
2
2
12”
12”
12”
15”
15”
NON-MERCURIAL SAFETY LAB THERMOMETERS (WHITEBACK)
IN RECOGNITION OF INCREASED WORKPLACE AND ENVIRONMENTAL CONCERNS, KESSLER HAS INTRODUCED AN EXPANDED LINE OF NON-MERCURIAL THERMOMETERS.
THESE INSTRUMENTS PROVIDE THE ACCURATE, RELIABLE READINGS EXPECTED OF A KESSLER THERMOMETER, WITH AN ENVIRONMENTALLY SAFE ALCOHOL OR MINERAL
SPIRITS FILLING. SEE ARTICLE LOCATED IN BACK OF CATALOG “THE NEW NON-MERCURIAL THERMOMETERS - JUST HOW GOOD ARE THEY?”
NON-MERCURIAL CELSIUS RANGES
CAT NO.
305mm
305mm
305mm
TOTAL IMMERSION
MEDIUM
RANGE
DIV
-200 to 30OC
-100 to 50OC
76MM IMMERSION
MEDIUM
RANGE
DIV LENGTH
LENGTH
CAT NO.
1
1
350mm
305mm
3134-3
3130-3
Alcohol
Alcohol
-100 to 50OC
-50 to 50OC
3300
Alcohol
-35 to 50OC
1
1
3136
3134
Pentane
Alcohol
3130
Alcohol
- 50 to 50OC
1
305mm
3300T
Alcohol
- 35 to 50OC
1
305mm
3302T
Min Spirits
- 20 to 110 C
1
305mm
3302
Min Spirits-
20 to 110OC
3304T
3306T
Min Spirits
Min Spirits
-20 to 150 C
-10 to 210OC
1
1
305mm
381mm
3304
3306
3308
Min Spirits
Min Spirits
Min Spirits
-20 to 150 C
-10 to 210OC
-10 to 250OC
O
O
O
1
1
1
1
305mm
1
305mm
381mm
381mm
NON-MERCURIAL FAHRENHEIT RANGES
CAT NO.
3138
3140
3316T
3320T
3324T
3328T
TOTAL IMMERSION
MEDIUM
RANGE
DIV
Alcohol
Alcohol
Alcohol
-150 to 120F
-60 to 120F
-30 to 120F
2
1
1
Min Spirits
Min Spirits
Min Spirits
-4 to 230F
-0 to 300F
-30 to 400F
2
2
2
LENGTH
12”
12”
12”
12”
12”
15”
3” IMMERSION
CAT NO. MEDIUM
RANGE
3138-3
3140-3
3316
3317
3320
3324
3328
3330
Alcohol
Alcohol
Alcohol
Alcohol
Min Spirits
Min Spirits
Min Spirits
Min Spirits
-150 to 120F
-60 to 120F
-30 to 120F
-30 to 120F
-4 to 230F
-0 to 300F
-30 to 400F
-30 to 485F
DIV LENGTH
2
1
1
0.5
2
2
2
2
12”
12”
12”
12”
12”
12”
15”
15”
NON-MERCURIAL TEFLON ENCAPSULATED
CELSIUS RANGES
CAT NO
2038T
2039T
2040T
2041T
TOTAL IMMERSION
TEMP RANGE
DIV
-35 to 50OC
-20 to 1OOC
-20 to 150OC
10 to 210OC
1
1
1
1
LENGTH
305mm
305mm
305mm
381mm
76MM IMMERSION
CAT NO TEMP RANGE
DIV
LENGTH
2038
2039
2040
2041
-35 to 50OC
-20 to 1OOC
-20 to 150OC
-10 to 210OC
1
1
1
1
305mm
305mm
305mm
381mm
3304
FAHRENHEIT RANGES
CAT NO
2042T
2043T
2044T
2045T
TOTAL IMMERSION
TEMP RANGE
DIV
-
30 to 120OF
-4 to 230OF
0 to 300OF
30 to 400OF
1
2
2
2
LENGTH
12”
12”
12”
15”
76MM IMMERSION
CAT NO TEMP RANGE
DIV
LENGTH
2042
2043
2044
2045
2046
-30 to 120OF
-4 to 230OF
0 to 300OF
30 to 400OF
30 to 485OF
1
2
2
2
2
12”
12”
12”
15”
15”
3134-3
Page 37
DEEP IMMERSION EXTENDED STEM &
VARI-IMMERSION THERMOMETERS
Page 39
Used for temperature measurement in deep vessels, flasks, ovens, sterilizers, incubators and similar equipment
where the greater depth is required for accurate reading. All graduated in 1 degree divisions.
MERCURY THERMOMETERS - YELLOW GLASS
CELSIUS RANGES
CAT NO
3098B
3098C
3099B
3099C
3100B
3100C
3100D
3101A
3101B
3101C
3101D
3102B
3102C
3102D
3103A
3103B
3103C
3103D
3104A
3104B
3104C
3104D
3106B
3106C
3106D
3108C
TEMP RANGE
-20
-10
-20
-10
-20
-10
-10
-20
-20
-10
-10
-20
-10
-10
-20
-20
-10
-10
-20
-20
-10
-10
-20
-10
-10
-10
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
150C
250C
150C
250C
150C
250C
360C
110C
150C
250C
360C
150C
250C
360C
110C
250C
250C
360C
110C
150C
250C
360C
150C
250C
360C
250C
DIV
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
IMMERSION
100mm
100mm
100mm
125mm
125mm
152mm
152mm
152mm
203mm
203mm
203mm
225mm
225mm
225mm
255mm
255mm
255mm
255mm
305mm
305mm
305mm
305mm
457mm
457mm
457mm
610mm
LENGTH
325mm
406mm
355mm
406mm
385mm
457mm
485mm
430mm
430mm
510mm
535mm
457mm
535mm
560mm
480mm
480mm
560mm
585mm
535mm
535mm
610mm
610mm
685mm
760mm
760mm
915mm
NON-MERCURIAL EXTENDED STEM THERMOMETERS - RED SPIRIT, WHITE GLASS
CAT NO
3098BRL
3098CRL
30998RL
3099CRL
3134-6
3130-6
3100BRL
3100CRL
3134-9
3130-9
31028RL
3I02CRL
3134-12
3130-12
3104BRL
3104CRL
3106BRL
3106CRL
TEMP RANGE
-20 to 150C
-10 to 250C
-20 to 150C
-10 to 250C
-100 to 50C
-50 to 50C
-20 to 150C
-10 to 250C
-100 to 50C
-50 to 50C
-20 to 150C
-10 to 250C
-100 to 50C
-50 to 50C
-20 to 150C
-10 to 250C
-20 to 150C
-10 to 250C
DIV
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
IMMERSION
100mm
100mm
125mm
125mm
152mm
152mm
152mm
152mm
225mm
225mm
225mm
225mm
305mm
305mm
305mm
305mm
457mm
457mm
LENGTH
325mm
406mm
355mm
430mm
385mm
385mm
385mm
457mm
457mm
457mm
457mm
535mm
535mm
535mm
535mm
610mm
685mm
760mm
3100C
3100C
DEEP IMMERSION EXTENDED STEM & VARI-IMMERSION
OVEN THERMOMETERS - MERCURY
FOR USE WITH FREEZE, THELCO AND MOST LABORATORY OVENS. ITEMS MARKED ‘*’ HAVE AN ENLARGEMENT AT THE IMMERSION POINT.
CAT NO
TEMP RANGE
DIV
IMMERSION
LENGTH
3112
-10 to 300C
1
305mm
610mm
3114*
3116*
3118*
3120*
3110
3122*
0 to 70C
+20 to 110C
35 to 230C
-10 to 250C
-10 to 200C
0 to 350C
1
1
1
1
1
1
125mm
165mm
125mm
152mm
305mm
178mm
305mm
305mm
305mm
485mm
585mm
510mm
VARI-IMMERSION THERMOMETERS
KESSLER VARI-IMMERSION THERMOMETERS ARE DESIGNED FOR USE IN WORK WHERE A REQUIREMENT FOR ADJUSTABLE IMMERSION DEPTH EXISTS. THE VARIIMMERSION WHEN USED IN CONJUNCTION WITH KESSLER’S TEFLON 10/18 STANDARD TAPER #4103 ADJUSTABLE ADAPTER PERMIT A VACUUM CAPABILITY NEARLY AS
HIGH AS A CONVENTIONAL GROUND GLASS JOINT. THE VARI-IMMERSION IS CONSTRUCTED OF TWO TYPES OF TUBING JOINED TOGETHER JUST BELOW THE SCALE. THE STEM
PORTION IS OF AN EXTREMELY FINE BORE GLASS TO MINIMIZE CORRECTION FACTORS AT IMMERSION DEPTHS OTHER THAN THE MID-POINT OF THE STEM. THE SCALE PORTION
IS OF A WIDE BORE GLASS TO FACILITATE READING OF THE INSTRUMENT AND TO ACCOMMODATE THE RANGES LISTED BELOW. EACH THERMOMETER IS FURNISHED WITH AN
INSTRUCTION SHEET AND LISTING OF CORRECTION FACTORS. GRADUATED IN SINGLE DEGREE DIVISIONS WITH PERMETCH MARKINGS.
MERCURY FILLED
CAT NO.
4100B
4100C
4100D
4102B
4102C
4102D
4104B
4104C
4104D
TEMP RANGE
-20
-10
-10
-20
-10
-10
-20
-10
-10
to 150ºC
to 250ºC
to 360ºC
to 150ºC
o 250ºC
to 360ºC
to 150ºC
to 250ºC
to 360ºC
IMMERSION
3” to 7” (76 - 178mm)
3” to 7” (76 - 178mm)
3” to 7” (76 - 178mm)
7” to 12” (178 - 305mm)
7” to 12” (178 - 305mm)
7” to 12” (178 - 305mm)
12” to 18” (305-457mm)
12” to 18” (305-457mm)
12” to 18” (305-457mm)
NON-MERCURIAL FILLED
CAT NO.
4100L
4100BRL
4100CRL
4102L
4102BRL
4102CRL
4104L
4104BRL
4104CRL
TEMP RANGE
-100 to 50ºC
-20 to 150ºC
-10 to 250ºC
-100 to 50ºC
-20 o 150ºC
-10 to 250ºC
-100 to 50ºC
-20 to 150ºC
-10 to 250ºC
IMMERSION
3” to 7” (76 - 178mm)
3” to 7” (76 - 178mm)
3” to 7” (76 - 178mm)
7” to 12” (178 - 305mm)
7” to 12” (178 - 305mm)
7” to 12” (178 - 305mm)
12” to 18” (305-457mm)
12” to 18” (305-457mm)
12” to 18” (305-457mm)
4100B
Page 41
ENVIRONMENTAL CHAMBER &
SPECIALTY
THERMOMETERS
Page 43
A precision mercury-in-glass thermometer, graduated in 0.5 degree divisions. Teflon encapsulated for extra safety,
mounted in a clear polycarbonate “bottle with mineral oil (sterilized sand for Oven model 1732) for use as a “heat
sink” prevents rapid change of indication when chamber is opened for inspection.
MEET EPA AND FDA REQUIREMENTS. NIST TRACEABLE
ENVIRONMENTAL CHAMBER BOTTLE THERMOMETERS
Our Environmental Chamber bottle Thermometers are offered in several ranges to observe critical
temperatures, such as Ultra Low Freezers, Blood Bank Refrigerators, Ovens and Incubators. Each
chamber-bottle thermometer is mounted in a square shaped plastic bottle filled with a medium to ensure
accurate readings despite the opening and closing of instrument doors.
The thermometers have engraved stems and are thoroughly annealed for long-lasting accuracy.
Each thermometer has its own individual serial number and has been calibrated according
to NIST standards.
A certificate of accuracy is included with each thermometer making it traceable to NIST.
We offer these thermometers with your choice of either mercury or mineral spirits, with a Teflon
coating for safety, which absorbs shock, and will contain the glass and liquid should breakage occur.
The Environmental Chamber bottle also has a double magnet attached on one side so it can be
attached to the walls or doors of instruments to reduce space and breakage problems.
MERCURY FILLED
CAT NO
1716
1718
1719
1722
1723
1720
1732
1734
TEMP RANGE
-30 to 0OC
-5 to +15OC
-5 to 20ºC
+10 to +30OC
+18 to +50ºC
+30 to +45OC
+20 to +130OC
-5 to +205ºC
DIV
IMMERSION
0.5
0.5
0.5
0.5
0.5
0.5
1.0
1.0
Total
Total
Total
Total
Total
Total
Total
Total
APPLICATION
VERIFIED
AT:
APPLICATION
VERIFIED
AT:
Freezers
Refrigerators
Blood Bank
Incubators
Incubators
Incubators
Oven
Oven
-20, 0C
0, 10C
0, 15C
15, 25C
20, 37C
37, 44.5C
85, 120C
0, 180C
NON-MERCURIAL
CAT NO
1715RL
1716RL
1718RL
1719RL
1722RL
1723RL
1720RL
1732RL
TEMP RANGE
-90 to +20ºC
-30 to 0OC
-5 to +15OC
-5 to 20ºC
+10 to +30OC
+18 to +50ºC
+30 to +45OC
+20 to +130OC
DIV
IMMERSION
Total
Total
Total
Total
Total
Total
Total
Total
Ultra low Freezers
Freezers
Refrigerators
Blood Bank
Incubators
Incubators
Incubators
Oven
1734RL
-5 to +205ºC
1.0
Total
Oven
1
0.5
0.5
0.5
0.5
0.5
0.5
1.0
-60, 0C
-20, 0C
0, 10C
0, 15C
15, 25C
20, 37C
37, 44.5C
85, 120C
0, 180C
AUTOCLAVE
CONSTRICTED CAPILLARY DESIGN REGISTERS HIGHEST TEMPERATURE ATTAINED UNTIL MANUALLY RESET.
CAT NO
1530
1531
1532
TEMP RANGE
80 to 135OC
80 to 135OC
175 to 275OC
FEATURE
LENGTH
DIV
IMMERSION
FEATURE
LENGTH
DIV
IMMERSION
FEATURE
LENGTH
DIV
IMMERSION
FEATURE
LENGTH
DIV
IMMERSION
FEATURE
LENGTH
305mm
0.05
DIV
IMMERSION
FEATURE
LENGTH
DIV
IMMERSION
Maximum Registering
Maximum Registering
Maximum Registering
215mm
215mm
215mm
1.0
0.5
1.0
Total
Total
Total
LIQUID
Mercury
Mercury
Mercury
COLIFORM INCUBATOR
CAT NO
1700
1701
TEMP RANGE
34.5 to 46OC
34.5 to 46OC
Arrows @ 35, 37, 44.5
Arrows, @ 35, 37, 44.5
240mm
152mm
0.1
0.1
76mm
Total
Mercury
Mercury
INCU-BLOK
CAT NO
1702
1702RL
TEMP RANGE
24 to 57OC
24 to 57OC
Arrows @ 25, 30, 37, 56
Arrows @ 25, 30, 37, 56
175mm
175mm
0.5
0.5
35mm
35mm
Mercury
Mineral Spirits
BLOOD BANK
CAT NO
1704
1704RL
TEMP RANGE
-5 to 20OC
-5 to 20OC
4 & 6C Marked with arrows
4 & 6C Marked with arrows
152mm
152mm
1.0
1.0
Total
Total
Mercury
Mineral Spirits
ENZYMOLOGY
CAT NO
1706
TEMP RANGE
24 to 38OC
Extremely Sensitive
95mm
Mercury
TRI-TEMP
CAT NO
1708
1708RL
TEMP RANGE
25, 37, 56OC
25, 37, 56OC
Graduated only at test pts.
Graduated only at test pts.
238mm
238mm
1702
1702RL
0.5
0.5
76mm
76mm
Mercury
Mineral Spirits
ENVIRONMENTAL CHAMBER & SPECIALTY THERMOMETERS
SPECIALTY THERMOMETERS
1530
Page 45
POCKET, MAXIMUM REGISTERING
AND SPECIALTY THERMOMETERS
Page 47
IN
RESPONSE TO AN INCREASED AWARENESS OF ENVIRONMENTAL, WORKPLACE SAFETY, AND QUALITY CONTROL CONSIDERATIONS,
KESSLER HAS EXPANDED ITS LINE OF TEFLON ENCAPSULATED THERMOMETERS.
MAXIMUM REGISTERING THERMOMETERS
‘EASY SHAKER’ MAXIMUM THERMOMETERS
THESE THERMOMETERS ARE USEFUL FOR DETERMINING THE HIGHEST TEMPERATURE ATTAINED IN LOCATIONS WHERE IT IS INCONVENIENT OR IMPOSSIBLE TO MEASURE THE
TEMPERATURE WITH A CONVENTIONAL INDICATING THERMOMETER. DESIGNED WITH A CONSTRICTION IN THE MERCURY COLUMN, THESE THERMOMETERS WILL DISPLAY AND
RETAIN THE HIGHEST TEMPERATURE OBTAINED UNTIL MANUALLY ‘SHAKEN DOWN’ OR RESET, SIMILAR TO A FEVER THERMOMETER. THERMOMETERS ARE FURNISHED IN PROTECTIVE CASES WITH A POCKET CLIP OR AS A REFILL THERMOMETER ONLY. LENGTH APPROXIMATELY 5-1/2”
COMPLETE WITH
CAT NO
REFILL UNIT ONLY
CAT NO
TEMP RANGE
CASE
TEMP RANGE
DIV
1510
0 to 220OF
2
1511
30 to 300OF
2
O
1512
30 to 300 F
2
O
1513
30 to 300 F
2
1514
30 to 300OF
2
1520
-20 to 110OC
1
1522
-5 to 200OC
2
SEE ALSO AUTOCLAVE MAXIMUM REGISTERING THERMOMETER ON PAGE #
1510R
1511R
1512R
1513R
1514R
1520R
1522R
0 to 220OF
30 to 300OF
30 to 300OF
30 to 300OF
30 to 300OF
-20 to 110OC
-5 to 200OC
DIV
2
2
2
2
2
1
2
‘HARD SHAKER’ MAXIMUM THERMOMETERS
IDENTICAL IN FUNCTION TO THE ABOVE MENTIONED THERMOMETERS, THESE UNITS ARE DESIGNED WITH A SEVERELY RESTRICTED CAPILLARY TO RESIST VIBRATION AND ARE
COMMONLY USED IN SERVICE SUCH AS OIL WELL LOGGING AND GEOTHERMAL EXPLORATION.
CANNOT BE RESET MANUALLY - REQUIRES A CENTRIFUGE TO RESET!
CAT NO
TEMP RANGE
DIV
LENGTH
CAT NO
TEMP RANGE
DIV
LENGTH
1636
1640
1642
1644
1662
-20 to 120OC
14 to 166OC
40 to 206OC
90 to 260OC
200 to 350OC
2
2
2
2
2
6.25”
5”
6.25”
6.25”
5”
1638
1641
1643
1645
14 to 106OC
25 to 200OC
0 to 200OF
90 to 260OF
2
2
2
2
6.25”
6.25”
5.5”
5”
1540
1544
1548
1552
1556
1559
1562
60 to 220OF
0 to 300OF
100 to 300OF
100 to 400OF
200 to 400OF
200 to 500OF
400 to 650OF
2
2
2
2
2
2
2
5.5”
5.5”
5.5”
5.5”
5.5”
5.5”
5”
1542
1546
1550
1554
1558
1560
1564
60 to 220OF
0 to 300OF
60 to 330OF
100 to 400OF
200 to 500OF
200 to 500OF
350 to 650OF
2
2
2
2
2
2
2
6.25”
6.25”
5”
6.25”
5”
6.25”
6.25”
MIN-MAX THERMOMETER
THERMOMETER REGISTERS HIGH AND LOW READINGS FROM LAST SETTING. PLASTIC CASE. PUSH BUTTON RESET.
DUAL SCALE: -40/120ºF & -40/50ºC (MERCURY FILLED)
CAT. NO. 5460
THERMOMETER REGISTERS HIGH AND LOW READINGS FROM LAST SETTING. PLASTIC CASE. MAGNETIC RESET.
DUAL SCALE: -40/120ºF & -40/50ºC (MERCURY FILLED)
CAT. NO. 5465
POCKET THERMOMETERS
POCKET THERMOMETERS ARE FURNISHED IN PROTECTIVE CASES WITH A POCKET CLIP OR AS A REFILL THERMOMETER ONLY. LENGTH APPROXIMATELY 5-1/2”.
5465
5460
1522
MERCURY FILLED
TEMP. RANGE
DIV
COMPLETE
CASE
W/METAL
-35 to 50OC
-10 to 110OC
-30 to 120OF
+30 to 120OF
0 to 220ºF
0 to 300ºF
100 to 450ºF
1
1
2
1
2
2
5
COMPLETE
CASE
W/PLASTIC
3147
3148
3150
3152
3154
3156
3158
COMPLETE
FACE ARMOR
REFILL
W/OPEN
3147-B
3148-B
3150-B
3152-B
3154-B
3156-B
3158-B
3147-A
3148-A
3150-A
3152-A
3154-A
3156-A
3158-A
3147-R
3148-R
3150-R
3152-R
3154-R
3156-R
3158-R
NON-MERCURIAL - (MINERAL SPIRITS FILLED)
TEMP. RANGE
DIV
COMPLETE
CASE
W/METAL
COMPLETE
CASE
W/PLASTIC
COMPLETE
FACE ARMOR
REFILL
W/OPEN
-40 to 50OC
-10 to 110OC
-40 to 120ºC
-30 to 120OF
0 to 120ºF
0 to 220ºF
1
1
2
2
1
2
3142SP
3148SP
3149SP
3150SP
3151SP
3154SP
3142SP-B
3148SP-B
3149SP-B
3150SP-B
3151SP-B
3154SP-B
3142SP-A
3148SP-A
3149SP-A
3150SP-A
3151SP-A
3154SP-A
3142-RSP
3148-RSP
3149-RSP
3150-RSP
3151-RSP
3154-RSP
0 to 300ºF
2
3156SP
3156SP-B
3156SP-A
3156-RSP
3148
ASPHALT, SOIL, AND CONCRETE TESTING THERMOMETERS
CAT NO
6300
6308
6310
6320
6400
DESIGNATION
Asphalt Testing
Asphalt Testing
Asphalt Testing
Concrete, soils
pocket Concrete
TEMP RANGE
GRAD
50 to 450OF
10 to 310OC
50 to 600OF
0 to 120OF
0 to 120OF
5
2
5
1
1
IMMERSION
Stem
Stem
Stem
Stem
Bulb
SPECIAL FEATURES
With penetration armor
With penetration armor
With penetration armor
With penetration armor
w/pocket case, plated bulb
DEEP FRY (FAST FOODS) CALIBRATION THERMOMETERS
CAT NO
6420
6420R
DESIGNATION
Fry calibration
Fry calibration
TEMP RANGE
GRAD
120 to 430OF
120 to 430OF
2
2
IMMERSION
SPECIAL FEATURES
4-6” Teflon Encapsulated, w/armor case, 16” lg.
4-6”
Refill thermometer only
WEATHER BUREAU METEOROLOGICAL THERMOMETERS
CAT NO
6500S
6500
6502
6520
6522
6540
6542
6560
6562
DESIGNATION
TEMP RANGE
USWB Sling Psychrometer -30 to 120OF
USWB Sling Psychrometer -20 to 120OF
USWB Sling Psychrometer -30 to 50OC
USWB Maximum Thermometer -20 to 120OF
USWB Maximum Thermometer -25 to 65OC
USWB Minimum Thermometer -40 to 110OF
USWB Minimum Thermometer -40 to 45OC
USWB ‘Exposed’
-38 to 110OF
USWB ‘Exposed’
-38 to 45OC
FOR THERMOMETER OR PSYCHROMETER REFILL TUBE ONLY ADD ‘R’ TO CATALOG NUMBER.
DIV
1
1
1
1
1
1
1
1
1
IMMERSION
TTL
TTL
TTL
TTL
TTL
TTL
TTL
TTL
TTL
SPECIAL FEATURES
POCKET & MAXIMUM REGISTERING THERMOMETERS
POCKET CASE ONLY CAT NO. 3155.
w/frame, handle, wicks
w/frame, handle, wicks
w/frame, handle, wicks
w/stainless backplate
w/stainless backplate
w/stainless backplate
w/stainless backplate
w/stainless backplate
w/stainless backplate
6300
6500
Page 49
JOINTED
THERMOMETERS
Page 51
KESSLER ST (Standard Taper) jointed thermometers are uniquely fabricated by enlarging and molding the stem
glass to the required size, then precision grinding to a true standard taper for a perfect fit. This style of fabrication
avoids the inherent weaknesses found in ordinary jointed thermometers built from 3 separate pieces of glass.
10/30 ST JOINTED THERMOMETERS (MERCURY FILLED)
FABRICATED FROM YELLOW GLASS, ALL IN 1 DEGREE C DIVISIONS.
STEM LENGTH
1” (25mm)
1.5” (38mm)
2” (51mm)
2.5” (63mm)
3” (76mm)
4” (100mm)
5” (125mm)
6” (152mm)
7” (178mm)
7.5” (190mm)
8” (203mm)
8.5” (215mm)
9” (225mm)
10” (255mm)
11” (280mm)
12” (305mm)
-20
TO
110OC
3998A
--------3999A
--------4000A
4001A
4002A
4003A
4004A
4005A
4006A
4007A
4008A
4009A
4010A
4011A
-20
TO
150OC
3998B
--------3999B
--------4000B
4001B
4002B
4003B
4004B
4005B
4006B
4007B
4008B
4009B
4010B
4011B
-10
TO
250OC
3998C
3998.5C
3999C
3999.5C
4000C
4001C
4002C
4003C
4004C
4005C
4006C
4007C
4008C
4009C
4010C
4011C
-10
TO
360OC
3998D
--------3999D
--------4000D
4001D
4002D
4003D
4004D
4005D
4006D
4007D
4008D
4009D
4010D
4011D
10/30 ST JOINTED THERMOMETERS (NON-MERCURIAL)
FABRICATED FROM WHITE GLASS, ALL IN 1 DEGREE C DIVISIONS, MINERAL SPIRITS FILLED.
STEM LENGTH
1” (25mm)
2” (51mm)
3” (76mm)
4” (100mm)
5” (125mm)
6” (152mm)
7” (178mm)
7.5” (190mm)
8” (203mm)
8.5” (215mm)
9” (225mm)
10” (255mm)
11” (280mm)
12” (305mm)
-20
TO
110OC
-----------------------------------------------------------------------------------------------------------------
-20
TO
150OC
3998BRL
3999BRL
4000BRL
4001BRL
4002BRL
4003BRL
4004BRL
4005BRL
4006BRL
4007BRL
4008BRL
4009BRL
4010BRL
4011BRL
-10
TO
250OC
3998CRL
3999CRL
4000CRL
4001CRL
4002CRL
4003CRL
4004CRL
4005CRL
4006CRL
4007CRL
4008CRL
4009CRL
4010CRL
4011CRL
10/18 ST JOINTED THERMOMETERS
FABRICATED FROM YELLOW GLASS, ALL IN 1 DEGREE C DIVISIONS.
STEM LENGTH
1”
2”
3”
4”
5”
(25mm)
(51mm)
(76mm)
(100mm)
(125mm)
-20
TO
110OC
-----------------------------------------
-20
TO
150OC
4098B
4099B
-------------------------
-10
TO
250OC
4098C
4099C
4500C
4501C
4502C
-10
TO
360OC
4098D
4099D
4500D
-----------------
4003CRL
4099C
4003D
JOINTED THERMOMETERS
10/30 ST JOINTED THERMOMETERS (TEFLON ENCAPSULATED)
NEW FROM KESSLER, THESE TEFLON ENCAPSULATED THERMOMETERS REDUCE CHANCES OF JOINT SEIZURE FROM GLASS-TO-GLASS BINDING, AND
GREATLY DECREASE CHANCES OF CONTAMINATION FROM SPILLED MERCURY OR GLASS FRAGMENTS.
STEM LENGTH
1”
2”
3”
4”
5”
6”
(25mm)
(51mm)
(76mm)
(100mm)
(125mm)
(152mm)
-20
TO
150OC
4400B
4402B
4404B
4406B
4408B
4410B
-10
TO
250OC
4400C
4402C
4404C
4406C
4408C
4410C
7/12 ST JOINTED ‘MICRO’ THERMOMETERS
FABRICATED FROM WHITE GLASS, 150C IN 1 DEGREE C DIVISIONS, 300C IN 2 DEGREE C DIVISIONS
STEM LENGTH
2cm (20mm)
3cm (30mm)
4cm (40mm)
5cm (50mm)
6cm (60mm)
7cm (70mm)
8cm (80mm)
9cm (90mm)
10cm (100mm)
0
TO
150OC
4206E
4208E
4210E
4212E
4214E
4216E
4218E
4220E
4222E
0
TO
300OC
4206F
4208F
4210F
4212F
4214F
4216F
4218F
4220F
4222F
TEFLON ADJUSTABLE 10/18 ADAPTERS
10/18 STANDARD TAPER ADJUSTABLE TEFLON ADAPTER. ALLOWS VARI-IMMERSION THERMOMETERS TO BE USED IN 10/18 OR 10/30 FEMALE JOINTS.
CAT NO. 4103
4206E
Page 53
GAUGING
EQUIPMENT
15
14
13
12
11
10
9
8
K OLO
W
AT
E
R
FI
R
N
D
IN
KUT
G
KOLOR KUT
PA
ST
7
6
5
E
4
GASOLINE GAUGING PASTE
3
2
Page 55
OIL SAMPLERS
MIDTANK SAMPLER
MAY BE USED TO OBTAIN STRATIFICATION SAMPLE FROM ANY POINT IN TANK OR PRESET TO OBTAIN SAMPLE STARTING ANY PLACE UP TO 12” FROM TANK BOTTOM.
LOWERED BY MEANS OF TAPE OR CHAIN IN OPEN POSITION. A SHARP TUG ON THE LINE CLOSES THE VALVE AND SECURES SAMPLE.
CAT NO MTS-12 - WITH 12” GRADUATED ACRYLIC CYLINDER
CAT NO MTS-15 - WITH 16” GRADUATED ACRYLIC CYLINDER
“BACON BOMB” BOTTOM SAMPLERS
FOR SAMPLING OF PETROLEUM IN ACCORDANCE WITH ASTM METHOD D-275. ERROR FREE ONE LINE PICKUP OF BOTTOM SAMPLE. MAY ALSO BE USED FOR MIDPOINT SAMPLING WITH ADDITION OF SECONDARY ‘TRIP’ LINE.
CAT NO
277
277A
277B
277C
277D
CAPACITY
32oz
16oz
8oz
4oz
4oz
Slimline Pencil type (1 1/8” OD fits narrow fill pipes
WEIGHTED SAMPLER
277A
WEIGHTED COPPER BEAKER OF NICKEL PLATED BRASS CONSTRUCTION. ONE QUART CAPACITY WITH CORK CLOSURE AND BRASS CHAIN SECURING CORK TO HANDLE
CAT NO WCB-1 - 3/4” OPENING
CAT NO WCB-2 - 1 1/2” OPENING
GAUGING PASTE (FROM KOLOR KUT)
WEIGHTED COPPER BEAKER OF NICKEL PLATED BRASS CONSTRUCTION. ONE QUART CAPACITY WITH CORK CLOSURE AND BRASS CHAIN SECURING CORK TO HANDLE
CAT NO WFP - WATER FINDING PASTE
CAT NO GGP - GASOLINE GAUGING PASTE
WFP
LUFKIN GAUGING TAPES
GGP
CHROME-NUBIAN (CN) STYLE (HALF OF THE TAPE FACE IS CHROME, HALF FLAT BLACK) PERMITS GAUGING OF BOTH LIGHT AND DARK PRODUCTS WITH ONE TAPE.
MTS-15
INNAGE TAPES
(REQUIRE 590
SERIES PLUMB
BOB)
LENGTH
ENGLISH (FT & INCHES) ONLY
ENGLISH-METRIC
25’
33’
50’
66’
75’
100’
50’
50’
66’
CN1290SF590
CN1291SF590
CN1293SF590
CN1294SF590
CN1295SF590
CN1296SF590
CN1293SD590
CN1293SF587
CN1294SF587
N/A
N/A
CN1293SMEF590
CN1294SMEF590
N/A
CN1296SMEF590
Graduated in feet and tenths
CN1293SMEF587
CN1294SMEF587
DUAL SCALE
CN1295SF590
(50’ & 15m)
(66’ & 20m)
(100’ & 30m)
(50’ & 15m)
(66’ & 20m)
PLEASE NOTE: THE ABOVE NUMBERS SPECIFY TAPES COMPLETE WITH REEL AND HANDLE.
TO ORDER REFILL TAPE ONLY, ADD PREFIX ‘0’ BEFORE CATALOG NUMBER. TAPES DO NOT INCLUDE BOB. ORDER BOB SEPARATELY!
LUFKIN GAUGING BOBS
ENGRAVED BRASS PLUMB BOBS FOR USE WITH THE ABOVE GAUGING TAPES.
6” INNAGE BOBS
6” OUTAGE (ULLAGE) BOBS
CAT NO.
FEATURE
CAT NO.
FEATURE
590
590G
590GME
590SD
Ungraduated
Graduated in inches to 1/8”
Graduated in inches and mm
Use with SD Tapes
587
587-1/2
587GME
Graduated in inches
Graduated in inches to 1/8”
Graduated in metric & english
590SD
590G
GAUGING EQUIPMENT
CYLINDRICAL BRASS CUPCASE GAUGING THERMOMETERS
12” LENGTH BY 1-3/4” DIAMETER
PRINTED SCALE
WITH LARGE, VIVID LINES AND NUMERALS FOR QUICK, EASY READING AT A GLANCE.
TEMP RANGE
DIV
-10 to 110OF
0 to 200OF
1
1
COMPLETE
WITH CASE
5103
5104
REFILL
UNIT ONLY
5103R
5104R
ENGRAVED STEM
LINES AND NUMBERS ETCHED INTO THE GLASS FOR EVEN GREATER ACCURACY.
TEMP RANGE
DIV
0 to 90OF
+10 to 100OF
-10 to 100OF
0 to 200OF
0 to 220OF
20 to 260OF
100 to 300OF
+30 to 450OF
-50 to 50OC
-35 to 50OC
-30 to 100OC
0.5
0.5
1
1
1
1
1
2
0.5
0.5
1
COMPLETE
WITH CASE
5108ES
5109ES
5103ES
5104ES
5106ES
5107ES
5105
5115ES
5110ES
5114ES
5112ES
REFILL
UNIT ONLY
5108RES
5109RES
5103RES
5104RES
5106RES
5107RES
5105R
5115RES
5110RES
5114RES
5112RES
12” LENGTH BY 1” DIAMETER
ENGRAVED STEM
LINES AND NUMBERS ETCHED INTO GLASS FOR ACCURACY. NARROW 1” OD PERMITS INSERTION THROUGH 1 1/2” FILL PIPES.
TEMP RANGE
DIV
-20 to 120OF
-10 to 220OF
30 to 320OF
35 to 50OC
1
2
2
0.5
COMPLETE
WITH CASE
5100
5101
5102
5111
REFILL
UNIT ONLY
5100R
5101R
5102R
5111R
10” LENGTH BY 1” DIAMETER
ENGRAVED STEM
LINES AND NUMBERS ETCHED INTO GLASS FOR ACCURACY. NARROW 1” OD PERMITS INSERTION THROUGH 1 1/2” FILL PIPES.
TEMP RANGE
DIV
-20 to 120OF
-10 to 220OF
+30 to 320OF
1
2
2
COMPLETE
WITH CASE
5100
5101-10
5102-10
REFILL
UNIT ONLY
5100R
5101R-10
5102R-10
5104
Page 57
ASTM TANK GAUGING THERMOMETERS
ASTM
AND SIMILAR (NO ASSIGNED
ASTM
NUMBER BUT MANUFACTURED TO THE IDENTICAL SPECIFICATIONS) TANK THERMOMETERS MAY BE FURNISHED IN ANY OF THE THREE
FOLLOWING CASES OR AS REFILL UNITS ONLY.
STANDARD CASE
(CASE ONLY - CAT NO 1259)
LONG ACCEPTED FAVORITE FOR GAUGING AS SPECIFIED IN ASTM METHOD D270
MARINE CASE
(CASE ONLY - CAT NO 1259CM)
SPECIALLY ADAPTED WITH GROUNDING PLATE TO CONDUCT STATIC BUILDUP TO TAPE AND AWAY FROM PRODUCT. DEFLECTOR LID ON CUP OPENS ON DESCENT, CLOSES ON ASCENT TO
PREVENT ‘WASHING’ EFFECT OF UNIT BEING DRAWN UP THROUGH PRODUCT AT LESSER DEPTHS.
TANKMASTER CASE
(CASE ONLY - CAT NO 1259TM)
THE MOST VERSATILE AND WELL DESIGNED GAUGING THERMOMETER CASE ON THE MARKET TODAY. CONSTRUCTED OF DUPONT ZYTEL, IT IS IMPERVIOUS TO CHEMICALS WHICH ATTACK
CONVENTIONAL MATERIALS. WILL NOT GENERATE OR CONDUCT STATIC ELECTRICITY. WEIGHTED TO AID RAPID DESCENT IN HEAVY PRODUCTS. OVERSIZED 120ML CAPACITY CUP PLUS
INSULATING PROPERTIES OF ZYTEL OFFER BETTER HEAD RETENTION CAPABILITIES. EXCEEDS REQUIREMENTS OF ASTM D-270. FOR CONTINUOUS USE TO 240F, INTERMITTENT USE
TO 300F. ACCEPTS THERMOMETERS WITH VARYING TOP FINISHES.
FAHRENHEIT RANGES (YELLOW
ASTM
58F
97F
59F
98F
130F
60F
TEMP RANGE
-30 to 120OF
0 to 120OF
0 to 120OF
0 to 180OF
60 to 180OF
0 to 220OF
20 to 220OF
20 to 260OF
170 to 500OF
LENS TUBING STANDARD*)
DIV
1
1
0.5
1
1
0.5
1
1
2
W/STANDARD
1250
1262C
1263C
1254
1264C
1240C
1261C
1294C
1258
CASE
W/MARINE
CASE
W/TANKMASER
CASE REFILL ONLY
CASE
W/MARINE
CASE
W/TANKMASER
CASE REFILL ONLY
1252CM
1262CM
1263CM
1256CM
1264CM
1240CM
1261CM
1294CM
1260CM
1252TM
1262TM
1263TM
1256TM
1264TM
1240TM
1261TM
1294TM
1260TM
1252
1262
1263
1256
1264
1240
1261
1294
1260
CELSIUS RANGES (YELLOW LENS TUBING STANDARD*)
ASTM
58C
97C
98C
59C
130C
60C
TEMP RANGE
-50 to 50OC
-34 to 49OC
-18 to 49OC
16 to 82OC
-18 to 82OC
-7 to 110OC
0 to 150OC
77 to 260OC
DIV
0.5
0.5
0.5
0.5
0.5
0.5
1
1
W/STANDARD
1247C
1248C
1244C
1246C
1253C
1271C
1242C
1257C
1247CM
1248CM
1244CM
1246CM
1253CM
1271CM
1242CM
1257CM
1247TM
1248TM
1244TM
1246TM
1253TM
1271TM
1242TM
1257TM
1247
1248
1244
1246
1253
1271
1242
1257
* ANY OF THE ABOVE MAY BE FURNISHED WITH RED READING LENS AT ADDITIONAL COST. TO ORDER, ADD SUFFIX “RRL” TO CATALOG NUMBER.
SMALL CUP & WOODBACK TANK THERMOMETERS
SIMILAR IN APPEARANCE AND CONSTRUCTION TO ASTM THERMOMETERS ABOVE BUT WITH SMALLER CUP, SHORTER OVERALL LENGTH. NARROW OD ALLOWS PASSAGE THROUGH 1
1/2 FILL PIPE.
CAT NO 5200 - RANGE -30 TO 120F IN 1 DIVISIONS COMPLETE WITH CASE
CAT NO 5200R - RANGE -30 TO 120F IN 1 DIVISIONS - REFILL THERMOMETER ONLY
CAT NO 5202 - RANGE -30 TO 180F IN 1 DIVISIONS COMPLETE WITH CASE
CAT NO 5202R - RANGE -30 TO 180F IN 1 DIVISIONS - REFILL THERMOMETER ONLY
GAUGING EQUIPMENT
1256TM
1256
1271C
Page59
ACCESSORIES
Page 61
Armor Cases
Leatherette Cases
Thermometer and Hydrometer Racks
TEFLON ADJUSTABLE 10/18 ADAPTERS
10/18 STANDARD TAPER ADJUSTABLE TEFLON ADAPTER. ALLOWS VARI-IMMERSION THERMOMETERS TO BE
USED IN 10/18 OR 10/30 FEMALE JOINTS.
CAT NO. 4103
AVAILABLE TO FIT MOST THERMOMETERS LISTED IN THIS CATALOG. KESSLER ARMORS ARE FABRICATED FROM SEAMLESS BRASS TUBING AND ARE DOUBLE NICKEL PLATED.
A RING IS FURNISHED AT THE TOP OF THE CASE FOR SUSPENSION. THE CUTOUT FRONT PORTION OF THE ARMOR ENABLES THE USER TO READ THE THERMOMETER SCALE WHILE
IN THE CASE.
3250
For 6” thermometers
3252** For 12” thermometers
3251
For 15” thermometers
3253** For 6 1/4” thermometers
3254**
3256**
3257**
3258SS
For 16” thermometers
For 18” thermometers
For 24” thermometers
For 30” thermometers only available in stainless steel
ACCESSORIES
ARMOR CASES FOR GLASS THERMOMETERS
** ALSO AVAILABLE IN STAINLESS STEEL. ADD “SS” TO CATALOG NUMBER.
LEATHERETTE STORAGE CASES
WOODEN, LEATHERETTE COVERED CASE WITH VELVET LINED INTERIOR. 2 SAFETY SNAPS ON COVER. CALIBRATION CERTIFICATE MAY BE FOLDED AND STORED IN CASE WITH THERMOMETER.
A ‘MUST’ FOR CERTIFIED OR EXPENSIVE THERMOMETERS TO PREVENT BREAKAGE IN STORAGE OR IN TRANSIT.
CAT NO
CAPACITY
3260
3262
3264
3265
3266
3267
3268
1 thermometer
1 thermometer
1 thermometer
1 thermometer
9 thermometers
9 hydrometers
10 hydrometers
MAXIMUM
LENGTH OF
THERMOMETER
12.5” (317mm)
16.5” (420mm)
18.5” (470mm)
24.5” (620mm)
16” (406mm)
12” (305mm)
15” (381mm)
PVC STORAGE CASES FOR THERMOMETERS AND HYDROMETERS
CONSTRUCTED OF RUGGED
APPLICATIONS.
PVC PLASTIC, LINED WITH HEAVY CARPET-LIKE CUSHIONING TO PROVIDE EXCEPTIONAL DURABILITY AND PROTECTION FOR THE INSTRUMENT IN FIELD
FRICTION-FIT CAP.
CAT NO
3270
3272
3274
3276
8960
8962
CAPACITY
MAXIMUM
1 thermometer
1 thermometer
1 thermometer
1 hydrometer
1 hydrometer
1 hydrometer
12”
16”
18”
24”
13”
15”
LENGTH
(305mm)
(406mm)
(457mm)
(610mm)
(330mm)
(385mm)
POLYPROPYLENE THERMOMETER AND HYDROMETER RACKS
FRAGILE GLASS THERMOMETERS AND HYDROMETERS ARE PROTECTED AND HELD IN THE PREFERRED UPRIGHT POSITION BY PLACING THEM IN THESE RACKS.
CAT NO
8990
8992
8998
TYPE
Hydrometers, long form
Hydrometers, short form
Thermometers
CAPACITY
Holds 9” to 15” hydrometers
Holds 6” to 9” hydrometers
Holds 6” and longer thermometers
THERMOMETER READING GLASS
THERMOMETER READING LENS, SINGLE ELEMENT TYPE, APPROXIMATE MAGNIFICATION 4X, FOCAL LENGTH 50MM. WITH SPRING CLIP
FOR ATTACHMENT DIRECTLY TO THERMOMETERS WITH OUTSIDE DIAMETER 6 TO 16MM. OBSERVATION TUBE HAS OPENING 5/32-INCH
DIAMETER TO FACILITATE READING WITHOUT PARALLAX.
CATALOG NO. 4300
Page 63
THERMOMETER CALIBRATION
EQUIPMENT
Page 65
Most laboratories are required to periodically reverify ALL their temperature measuring devices, from precision glass
thermometers to bimetal dial thermometers to thermistor based electronics. The KESSLER TCB-900 offers the
quality conscious laboratory the means to accurately and effectively compare these devices to an NIST Traceable
Certified Thermometer, thus satisfying the mandates of good practice and the requirements of regulatory agencies.
TEMPERATURE CALIBRATION SYSTEM
SATISFIES THE REQUIREMENTS OF THE F.D.A. & E.P.A
THE KESSLER TCB-900 THERMOMETER CALIBRATION BATH
HAS BEEN DESIGNED TO PERMIT CALIBRATION AND VERIFICATION OF
LIQUID-IN-GLASS THERMOMETERS, DIAL THERMOMETERS, DIGITAL
THERMOMETERS AND MOST ANY TEMPERATURE INSTRUMENT
THE WORKING DEPTH OF THE CONSTANT TEMPERATURE BACK IS 12”,
WHICH WILL PERMIT MOST 15” TOTAL IMMERSION THERMOMETERS
TO BE USED UNDER CORRECT CONDITIONS OF IMMERSION, AS WELL AS
ACCOMMODATING ALL PARTIAL IMMERSION THERMOMETERS.
REQUIRING THE USE OF A PRECISION TEMPERATURE COMPARATOR.
THE TCB-900 HAS BEEN DESIGNED AND BUILT TO SATISFY THE
REQUIREMENTS OF NIST SP 250-23 AND ASTM E-77.
THE TCB-900 CONSISTS OF A CONSTANT TEMPERATURE BATH AND
A SEPARATE, BUILT-IN DEWAR FLASK FOR COMPARISON OF CERTIFIED
AND ‘WORKING’ THERMOMETERS.
THE TCB-900 IS ENTIRELY SOLID CONTAINED, COMPACT AND
LIGHTWEIGHT, REQUIRING LITTLE COUNTER SPACE.
TEMPERATURES BELOW AMBIENT CAN BE ATTAINED BY CIRCULATING
TAP WATER THROUGH THE BUILT IN COOLING COIL. IN THE EVENT
YOUR LAB HAS REFRIGERATED RECIRCULATING EQUIPMENT, THE COOLANT CAN BE CIRCULATED THROUGH THE COIL, ALLOWING
OPERATION DOWN TO APPROXIMATELY -30C, DEPENDING UPON THE
CAPACITY OF YOUR EQUIPMENT.
LABORATORY
PRECISION
The calibration bath holds
temperatures to +/- 0.02C in
the range of +15 to 200C.
Adjustment is made by means of
a dial, with a large digital
readout.
201C in 0.2 divisions, 76mm Immersion,
Simply dial in the desired
temperature. Fine adjustment to
standard thermometer is made
by means of fine adjustment
knob.
200C
with protective storage case.
TCB-900
Controlled Chamber
12”
Ice Bath
10.5”
CONTROLLER
+/-0.02C
Electronic solid state digital - thermometer
sensor
READOUT
EASY,
AUTOMATIC
OPERATION
15C
24”length.
Certified traceable to NBS at 0, 20, 40,
60, 80, 100, 120, 140, 160, 180 200C,
MODEL
MINIMUM TEMP
MAXIMUM TEMP
UNIFORMITY
WORKING DEPTH
LED
Switchable Celsius or Fahrenheit
HEATER
OVERTEMP
THERMOMETER READING GLASS
ASTM E77
TEST METHOD
“Calibration and Verification of Liquid in
Glass Thermometers”
COMPLETE INSTRUCTIONS
1000W
CALIBRATION EQUIPMENT
TCB-900
Safety control protects against overheating - screwdriver adjustable from rear
of bath.
DRAINS
For both heated bath and ice bath
SAFETY
Overflow port
STAINLESS STEEL
Interior, steel exterior with corrosion resistant polyurethane finish.
COOLING COIL
VERSATILE
The system includes an ice bath
for performing ice points
calibration.
Main bath may be cooled below
ambient by circulating tap water
or refrigerated liquid through
built in cooling loop.
For operation at below ambient temperatures.
MOTOR
DIMENSIONS
1/15hp
WEIGHT
ELECTRICAL
SHIPPING WEIGHT
DIM
45lbs (dry)
17”
23”h x 18” x
THIS PRODUCT, ALL COMPONENTS
AND ACCESSORIES ARE MADE IN THE
UNITED STATES OF AMERICA.
110v AC 60C
66lbs
21 x 24 x 29 in
Accessories shipped separately
SPECIFICATIONS
SPECIFICATIONS
TURNTABLE RACK holds six thermometers plus port for standard thermometer.
CERTIFIED THERMOMETER
range -1/
Page 67
HYDROMETERS
Page 69
Popular in many applications due to small amount of product sample required to take a reading, these instruments
are manufactured to strict ASTM specifications and to KESSLER’s own demanding quality control standards.
ASTM HYDROMETERS - API - 6” LENGTH
CAT NO ASTM
7500
7502
7504
7506
7508
7510
7512
7514
7516
7518
7520
7522
7524
7526
7528
21H
22H
23H
24H
25H
26H
27H
28H
29H
30H
31H
32H
33H
34H
35H
API RANGE
0 to 6
5 to 11
10 to 16
15 to 21
20 to 26
25 to 31
30 to 36
35 to 41
40 to 46
45 to 51
50 to 56
55 to 61
60 to 66
65 to 71
70 to 76
DIV
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
CAT NO ASTM
API RANGE
DIV
CAT NO
API RANGE
DIV
7530
7532
7534
7536
7539
7550
7552
7554
7556
7558
7560
7562
7564
7566
36H
37H
38H
39H
-----------------------------------------
75 to 81
80 to 86
85 to 91
90 to 96
89 to 101
-1 to 11
9 to 21
19 to 31
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
79 to 91
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
HYDROMETERS - API - 4” LENGTH
ALLOW ACCURATE TESTING WITH AN EVEN SMALLER SAMPLE (4OZ) THAN ABOVE UNITS.
CAT NO
API RANGE
7500-4
7502-4
7504-4
7506-4
7508-4
7510-4
7512-4
7514-4
7516-4
7518-4
7520-4
7522-4
7524-4
7526-4
0 to 6
5 to 11
10 to 16
15 to 21
20 to 26
25 to 31
30 to 36
35 to 41
40 to 46
45 to 51
50 to 56
55 to 61
60 to 66
65 to 71
DIV
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
7530-4
7532-4
7534-4
7536-4
7539-4
7550-4
7552-4
7554-4
7556-4
7558-4
7560-4
7562-4
7564-4
7566-4
75 to 81
80 to 86
85 to 91
90 to 96
89 to 101
-1 to 11
9 to 21
19 to 31
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
79 to 91
-------------------------------------
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
SHORT FORM THERMO-HYDROMETERS
7502
APPROXIMATELY 190MM (7 1/2”) LENGTH. THERMOMETERS IN BODY.
CAT NO ASTM
7600
7602
7604
7606
7608
7610
7612
7614
7616
7618
ASTM LPG
-----------------------------------------
API RANGE
-1 to 11
9 to 21
19 to 31
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
79 to91
89 to 101
(LIQUEFIED PETROLEUM GAS)
DIV
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
TEMP RANGE
0
0
0
0
0
0
0
0
0
0
to
to
to
to
to
to
to
to
to
to
130OF
130OF
130OF
130OF
130OF
130OF
130OF
130OF
130OF
130OF
DIV
LENGTH
DIV
LENGTH
2
2
2
2
2
2
2
2
2
2
190mm
190mm
190mm
190mm
190mm
190mm
190mm
190mm
190mm
190mm
HYDROMETER
FOR TESTING OF LPG IN ACCORDANCE WITH ASTM METHODS.
CAT NO ASTM
7830
8814
310H
101H
SCALE RANGE
500 to 650 Kg/M3
-500 to -650 SG
DIV
1.0
.001
TEMP RANGE
0 to 35OC
30 to 90OC
0.5
1.0
355mm
355mm
7608
PETROLEUM HYDROMETERS
API SCALE FOR PETROLEUM PRODUCTS
MANUFACTURED STRICTLY IN ACCORDANCE WITH ALL APPLICABLE ASTM SPECIFICATIONS, THESE UNITS HAVE BECOME THE INDUSTRY STANDARD FOR CLOSE
ACCURATE READINGS. ALL INSTRUMENTS IN THIS SERIES ARE SUITABLE FOR CERTIFICATION AND AS SUCH SERVE AS PRIMARY REFERENCE STANDARDS IN MANY
GOVERNMENTAL AND PRIVATE LABORATORIES.
API SCALE FOR PETROLEUM PRODUCTS
WITHOUT THERMOMETER
CAT NO
7000
7002
7004
7006
7008
7010
7012
7014
7016
7018
7020
ASTM
1H
2H
3H
4H
5H
6H
7H
8H
9H
10H
API RANGE
-1 to 11
9 to 21
19 to 31
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
79 to 91
89 to 101
10 to 100
DIV
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
1.0
LENGTH
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
ASTM API THERMO-HYDROMETERS
380MM LENGTH - THERMOMETER IN BODY.
CAT NO ASTM*
API RANGE
DIV
TEMP RANGE
DIV
LENGTH
7050
51HH
-1 to 11
0.1
60 to 220OF
2
380mm
7050L
51HL
-1 to 11
0.1
0 to 150OF
2
380mm
7052
52HH
9 to 21
0.1
60 to 220OF
2
380mm
7052L
52HL
9 to 21
0.1
0 to 150OF
2
380mm
7054
53HM
19 to 31
0.1
30 to 180OF
2
380mm
7054L
53HL
19 to 31
0.1
0 to 150OF
2
380mm
O
7056
54HM
29 to 41
0.1
30 to 180 F
2
380mm
O
7056L
54HL
29 to 41
0.1
0 to 150 F
2
380mm
O
7058
55HL
39 to 51
0.1
0 to 150 F
2
380mm
O
7060
56HL
49 to 61
0.1
0 to 150 F
2
380mm
7062
57HL
59 to 71
0.1
0 to 150OF
2
380mm
7064
58HL
69 to 81
0.1
0 to 150OF
2
380mm
7066
59HL
79 to 91
0.1
0 to 150OF
2
380mm
7068
60HL
89 to 101
0.1
0 to 150OF
2
380mm
7076
-----10 to 30
0.2
0 to 150OF
2
380mm
O
7078
-----20 to 40
0.2
0 to 150 F
2
380mm
O
7080
-----30 to 50
0.2
0 to 150 F
2
380mm
O
7006
7082
-----40 to 60
0.2
0 to 150 F
2
380mm
O
7084
-----50 to 70
0.2
0 to 150 F
2
380mm
O
7088
-----70 to 90
0.2
0 to 150 F
2
380mm
7092
-----29 to 45
0.1
0 to 150OF
2
380mm
7094
-----33 to 48
0.1
0 to 150OF
2
380mm
7096
-----19 to 45
0.1
0 to 150OF
2
380mm
7098
-----30 to 90
0.5
0 to 150OF
2
380mm
* ASTM DESIGNATIONS FOR TEMPERATURE RANGES INDICATED: H (HIGH) 60/220F, M (MEDIUM) 30/180, L (LOW) 0/150F
ANY OF THESE RANGES CAN BE FURNISHED WITH THE HYDROMETERS LISTED ABOVE UPON REQUEST.
ASTM API THERMO-HYDROMETERS WITH THERMOMETER IN STEM
USEFUL FOR TESTING OF HEAVY OIL WHERE DARK COLOR PREVENTS READING THE THERMOMETER IN THE BODY OF A CONVENTIONAL THERMOHYDROMETER.
CAT NO ASTM*
7100
7102
7104
7106
7108
7110
7112
7114
71H
72H
73H
74H
-----------------
API RANGE
-1 to 11
9 to 21
19 to 31
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
DIV
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
TEMP RANGE
30
30
30
30
30
30
30
30
to
to
to
to
to
to
to
to
220OF
220OF
220OF
220OF
220OF
220OF
220OF
220OF
DIV
2
2
2
2
2
2
2
2
LENGTH
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
7056L
7056
Pageb71
Developed jointly with ISO (International Standards organization) standards to serve those users involved in
their international transport of petroleum products, this series has been adopted by ASTM and their use sanctioned as the metric standard for petroleum hydrometers. All comply with the demanding specifications set
forth in ASTM E-100-91
Graduated in Kg/M3 (Kilograms per cubic meter) @ 15 Degrees C for petroleum products.
ASTM METRIC DENSITY HYDROMETERS
CAT NO
7702
7704
7706
7708
7710
7712
7714
7716
7718
7720
ASTM
311H
312H
313H
314H
315H
316H
317H
318H
319H
320H
DENSITY RANGE
600 to 650
650 to 700
700 to 750
750 to 800
800 to 850
850 to 900
900 to 950
950 to 1000
1000 to 1050
1050 to 1100
DIV
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
LENGTH
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
330mm
ASTM METRIC THERMOHYDROMETERS
THERMOMETER IN BODY.
CAT NO ASTM*
7802
7804
7806
7806M
7808
7808M
7810
7810M
7812L
7812
7814L
7814
7816L
7816
7818
7818L
7820
7820L
300HL
301HL
302HL
302HM
303HL
303HM
304HL
304HM
305HL
305HM
306HL
306HM
307HL
307HH
308HH
308HL
309HH
309HL
DENSITY RANGE
600 to 650
650 to 700
700 to 750
700 to 750
750 to 800
750 to 800
800 to 850
800 to 850
850 to 900
850 to 900
900 to 950
900 to 950
950 to 1000
950 to 1000
1000 to 1050
1000 to 1050
1050 to 1100
1050 to 110
DIV
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
TEMP RANGE
-20 to 65OC
-20 to 65OC
-20 to 65OC
0 to 85OC
-20 to 65OC
0 to 85OC
-20 to 65OC
0 to 85OC
-20 to 65OC
0 to 85OC
-20 to 65OC
0 to 85OC
-20 to 65OC
+20 to 105OC
+20 to 105OC
-20 to 65OC
+20 to 105OC
-20 to 65OC
DIV
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LENGTH
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
380mm
7706
ASTM SPECIFIC GRAVITY SERIES
SPECIFIC GRAVITY HYDROMETERS 60/60F AS SPECIFIED IN ASTM E-100-91. (ALL SUITABLE FOR CERTIFICATION).
CAT NO
8001
8000
8002
8003
8004
8005
8006
8008
8010
8012
8014
8016
8020
8030
8032
8034
8036
ASTM
82H
83H
84H
85H
86H
87H
88H
89H
90H
98H
102H
103H
104H
105H
GRAVITY RANGE
.600 to .650
.650 to .700
.700 to .750
.650 to .750
.750 to .800
.750 to .850
.800 to .850
.850 to .900
.900 to .950
.950 to 1.000
1.000 to 1.050
1.050 to 1.100
.950 to 1.000
.650 to .700
.700 to .750
.750 to .800
.800 to .850
DIV
0.0005
0.0005
0.0005
--------0.0005
--------0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.001
0.001
0.001
0.001
LENGTH
330mm
330mm
330mm
---------330mm
---------330mm
330mm
330mm
330mm
330mm
330mm
330mm
260mm
260mm
260mm
260mm
8036
HYDROMETERS
ASTM SPECIFIC GRAVITY SERIES (CONTINUED)
SPECIFIC GRAVITY HYDROMETERS 60/60F AS SPECIFIED IN ASTM E-100-91. (ALL SUITABLE FOR CERTIFICATION).
CAT NO
8038
8040
8042
8200
8202
8204
8206
8208
8210
8212
8214
8216
8218
8230
8232
8234
8236
8238
8240
8242
8244
8246
8248
8250
8252
8254
8256
8258
8260
8262
8264
8266
8266
ASTM
106H
107H
108H
111H
112H
113H
114H
115H
116H
117H
118H
119H
120H
125H
126H
127H
128H
129H
130H
131H
132H
133H
134H
135H
136H
137H
138H
139H
140H
141H
142H
143H
144H
GRAVITY RANGE
.850 to .900
.900 to .950
.950 to 1.000
1.000 to 1.050
1.050 to 1.100
1.100 to 1.150
1.150 to 1.200
1.200 to 1.250
1.250 to 1.300
1.300 to 1.350
1.350 to 1.400
1.400 to 1.450
1.450 to 1.500
1.000 to 1.050
1.050 to 1.100
1.100 to 1.150
1.150 to 1.200
1.200 to 1.250
1.250 to 1.300
1.300 to 1.350
1.350 to 1.400
1.400 to 1.450
1.450 to 1.500
1.500 to 1.550
1.550 to 1.600
1.600 to 1.650
1.650 to 1.700
1.700 to 1.750
1.750 to 1.800
1.800 to 1.850
1.850 to 1.900
1.900 to 1.950
1.950 to 2.000
DIV
0.001
0.001
0.001
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
LENGTH
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
260mm
8230
8200
SPECIFIC GRAVITY HYDROMETERS SEQUENTIAL RANGES (60/60F)
6” HYDROMETERS IN - .070 SG RANGES
CAT NO
8140
8141
8142
8143
8144
8145
8146
8286
8287
8288
8289
8290
GRAVITY RANGE
.590 to .660
.650 to .710
.700 to .770
.760 to .830
.820 to .890
.880 to .950
.940 to 1.010
1.000 to 1.070
1.060 to 1.130
1.120 to 1.190
1.180 to 1.250
1.240 to 1.310
DIV
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
CAT NO
GRAVITY RANGE
CAT NO
GRAVITY RANGE
8291
8292
8293
8294
8295
8296
8297
8298
8299
8301
8303
1.300
1.360
1.420
1.480
1.540
1.600
1.660
1.720
1.780
1.840
1.910
to
to
to
to
to
to
to
to
to
to
to
1.370
1.430
1.490
1.550
1.610
1.670
1.730
1.790
1.850
1.920
1.980
DIV
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
6” HYDROMETERS - .100 SG RANGES
CAT NO
8100
8102
8104
8106
8300
8302
8304
GRAVITY RANGE
.600 to .710
.700 to .810
.800 to .910
.900 to 1.010
1.000 to 1.110
1.100 to 1.210
1.200 to 1.310
DIV
0.002
0.002
0.002
0.002
0.002
0.002
0.002
8306
8308
8310
8312
8314
8316
8318
1.300
1.400
1.500
1.600
1.700
1.800
1.900
to
to
to
to
to
to
to
1.410
1.510
1.610
1.710
1.810
1.910
2.010
DIV
0.002
0.002
0.002
0.002
0.002
0.002
0.002
8144
8286
Page 73
6” HYDROMETERS - .200 SG RANGES
CAT NO
8320
8322
8324
GRAVITY RANGE
1.000 to 1.220
1.200 to 1.420
1.400 to 1.620
DIV
CAT NO
0.005
0.005
0.005
8326
8328
8321
GRAVITY RANGE
1.600 to 1.820
1.800 to 2.000
1.100 to 1.300
LONG SPECIFIC GRAVITY HYDROMETERS SEQUENTIAL RANGES
DIV
0.005
0.005
0.005
(60/60F)
13” HYDROMETERS - .070 SG RANGES
CAT NO
8147
8148
8149
8150
8151
8152
8153
8270
8271
8272
8273
8274
GRAVITY RANGE
.600 to .660
.650 to .710
.700 to .770
.760 to .830
.820 to .890
.880 to .950
.940 to 1.010
1.000 to 1.070
1.060 to 1.130
1.120 to 1.190
1.180 to 1.250
1.240 to 1.310
DIV
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
CAT NO
GRAVITY RANGE
CAT NO
GRAVITY RANGE
CAT NO
GRAVITY RANGE
8275
8276
8277
8278
8279
8280
8281
8282
8283
8284
8285
1.300
1.360
1.420
1.480
1.540
1.600
1.660
1.720
1.780
1.840
1.910
to
to
to
to
to
to
to
to
to
to
to
1.370
1.430
1.490
1.550
1.610
1.670
1.730
1.790
1.850
1.920
2.010
DIV
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
12” HYDROMETERS - .100 SG RANGES
CAT NO
8130
8132
8134
8136
8350
8352
8354
GRAVITY RANGE
.600 to .710
.700 to .810
.800 to .910
.900 to 1.010
1.000 to 1.110
1.100 to 1.210
1.200 to 1.310
DIV
0.001
0.001
0.001
0.001
0.001
0.001
0.001
8356
8358
8360
8362
8364
8364
8366
1.300
1.400
1.500
1.600
1.700
1.800
1.900
to
to
to
to
to
to
to
1.410
1.510
1.610
1.710
1.810
1.910
2.010
DIV
0.001
0.001
0.001
0.001
0.001
0.001
0.001
12” HYDROMETERS - .200 SG RANGES
CAT NO
8369
8370
8371
8372
8373
8374
8376
GRAVITY RANGE
.900 to 1.100
1.000 to 1.220
1.100 to 1.300
1.200 to 1.300
1.300 to 1.500
1.400 to 1.620
1.600 to 1.820
DIV
0.002
0.002
0.002
0.002
0.002
0.002
0.002
12” HYDROMETERS - SPINDLE (VERY
8378
8382
8384
8386
8388
8386
LONG)
1.800
2.000
2.200
2.400
2.600
2.800
to
to
to
to
to
to
2.010
2.200
2.400
2.600
2.800
3.000
DIV
0.002
0.002
0.002
0.002
0.002
0.002
RANGES
A SPINDLE HYDROMETER ALLOWS THE USER TO EASILY ASCERTAIN THE GRAVITY OF AN UNKNOWN SOLUTION, SO THAT A MORE
PRECISE HYDROMETER CAN BE USED FOR THE ACTUAL MEASUREMENT.
CAT NO
8379
8380
8392
GRAVITY RANGE
1.000 to 1.600
1.000 to 2.000
2.000 to 3.000
DIV
0.005
0.010
.010
CAT NO
8396
8398
GRAVITY RANGE
.650 to 1.000
.700 to 1.000
8382
DIV
0.1
0.005
8369
HYDROMETERS
DUAL SCALE - SPECIFIC GRAVITY & BAUME
SPECIFIC GRAVITY, PERHAPS THE MOST COMMONLY USED SCIENTIFIC SCALE, IS EXPRESSED AS THE RATIO OF THE MASS (WEIGHT) OF A GIVEN VOLUME OF LIQUID TO THE
IDENTICAL VOLUME OF WATER, BOTH LIQUIDS USUALLY AT AN EQUAL TEMPERATURE, MOST OFTEN 60F (15.56C).
BAUME IS MOST OFTEN USED IN THE CHEMICAL INDUSTRY. THE BAUME SCALE IS EXPRESSED AS ‘LIGHT’ FOR LIQUIDS WITH A GRAVITY BELOW 1.000 SG, OR ‘HEAVY’
FOR LIQUIDS WITH A GRAVITY HEAVIER THAN 1.000 SG. IN THE ABSENCE OF THE DESIGNATION ‘LIGHT’ OR ‘HEAVY’, IT IS ASSUMED TO BE HEAVY. BAUME LIGHT (BL) IS
DEFINED AS BL = (140/SG) - 130. BAUME HEAVY (BH) IS DEFINED AS BH = 145 - (145/SG).
SPECIFIC GRAVITY & BAUME LIGHT
CAT NO
8799.6
8799.8
8800
8801
8805
8804
8802
8802.5
8803
SPECIFIC GRAVITY
.600 to 1.000
.650 to 1.000
.700 to .810
.700 to .860
.700 to 1.000
.800 to 1.000
.800 to .910
.840 to 1.000
.900 to 1.010
BAUME LIGHT
DIV, SG
DIV, BAUME
LENGTH
BAUME HEAVY
DIV, SG
DIV, BAUME
LENGTH
0 to 26
24 to 43
42 to 55
54 to 65
64 to 73
0 to 45
0 to 55
40 to 72
0 to 70
.002
.002
.002
.002
.002
.005
.010
.010
.010
0.2
0.2
0.2
0.2
0.2
0.5
1.0
0.5
1.0
12”
12”
12”
12”
12”
12”
12”
12”
12”
100 to 10
85 to 10
70 to 45
70 to 35
70 to 10
45 to 10
45 to 25
37 to 10
25 to 10
.005
.005
.001
.002
.005
.005
.001
.002
.001
1.0
1.0
0.5
0.5
1.0
1.0
0.2
0.5
1.0
12”
12”
12”
12”
12”
12”
12”
12”
12”
SPECIFIC GRAVITY & BAUME HEAVY
CAT NO
8806-6
8807-6
8808-6
8809-6
8810-6
8810.5-6
8812-6
8813-6
8806
8807
8808
8809
8810
8810.5
8811
8812
8813
SPECIFIC GRAVITY
1.000
1.200
1.400
1.600
1.800
1.000
1.400
1.000
to
to
to
to
to
to
to
to
1.220
1.420
1.620
1.820
2.020
1.400
2.000
2.000
1.000
1.200
1.400
1.600
1.800
1.000
1.000
1.400
1.000
to
to
to
to
to
to
to
to
to
1.220
1.420
1.620
1.820
2.020
1.450
1.600
2.000
2.000
0 to 26
24 to 43
42 to 55
54 to 65
64 to 73
0 to 41
40 to 72
0 to 70
.005
.005
.005
.005
.005
.010
.010
.020
0.5
0.5
0.5
0.5
0.5
1.0
1.0
1.0
6”
6”
6”
6”
6”
6”
6”
6”
SPINDLE HYDROMETER (VERY LONG) RANGE
A SPINDLE HYDROMETER ALLOWS THE USER TO EASILY ASCERTAIN THE GRAVITY
MORE PRECISE HYDROMETER CAN BE USED FOR THE ACTUAL MEASUREMENT.
CAT NO
8815
SPECIFIC GRAVITY
.700 to 2.000
OF AN UNKNOWN SOLUTION, SO THAT A
BAUME HEAVY
70 Lt to 70 Hvy
DIV, SG
.010
DIV, BAUME
1.0
LENGTH
18”
8806-6
SPINDLE THERMOHYDROMETERS (VERY LONG) RANGES
A SPINDLE HYDROMETER ALLOWS THE USER TO EASILY ASCERTAIN THE GRAVITY
MORE PRECISE HYDROMETER CAN BE USED FOR THE ACTUAL MEASUREMENT.
CAT NO
8819
8820
8821
8822
SPECIFIC GRAVITY
.600 to 1.000
1.000 to 2.000
1.000 to 2.000
.650 to 1.000
OF AN UNKNOWN SOLUTION, SO THAT A
BAUME HEAVY
85 Lt to 10 Lt
0 to 72
DIV, SG
.005
.010
.010
.005
DIV, BAUME
0.5
1.0
TEMP RANGE
0
0
0
0
to
to
to
to
120OF
120OF
120OF
120OF
Page 75
BAUME HYDROMETERS (MODULUS 145, TEMPERATURE 60F)
12” BAUME HEAVY HYDROMETERS
CAT NO
8500
8501
8502
8503
8506
8508
8508.5
8509
8515
8510
8516
8511
RANGE, BAUME
0 to 50
0 to 70
0 to 25
0 to 35
-5 to +5
-1 to 11
5 to 15
9 to 21
15 to 25
19 to 31
25 to 35
29 to 41
DIV
0.5
1.0
0.5
0.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
CAT NO
RANGE, BAUME
33 to 37
35 to 45
35 to 70
39 to 51
45 to 55
49 to 61
55 to 65
59 to 71
64 to 66.5
69 to 81
79 to 91
89 to 101
0.05
0.1
0.5
0.1
0.1
0.1
0.1
0.1
0.05
0.1
0.1
0.1
CAT NO
RANGE, BAUME
DIV
CAT NO
RANGE, BAUME
DIV
8511.5
8517
8517.5
8512
8518
8513
8519
8514
8514.5
8520
8522
8524
DIV
6” BAUME HEAVY HYDROMETERS
CAT NO
8550
8551
8552
8557
8563
8564
RANGE, BAUME
0 to 20
20 to 40
40 to 60
0 to 70
-1 to 11
9 to 21
DIV
0.5
0.5
0.5
1.0
0.2
0.2
8565
8566
8567
8568
8569
19
29
39
49
59
to
to
to
to
to
31
41
51
61
71
0.2
0.2
0.2
0.2
0.2
12” BAUME LIGHT HYDROMETERS
CAT NO
8508LT
8509LT
8510LT
8511LT
RANGE, BAUME
-1 to 11
9 to 21
19 to 31
29 to 41
DIV
0.1
0.1
0.1
0.1
8512LT
8513LT
8514LT
39 to 51
49 to 61
59 to 71
0.1
0.1
0.1
TWADDLE SCALE HYDROMETERS
CAT NO
8570
8571
8572
8573
8574
8575
RANGE
DIV
0 to 26
24 to 50
48 to 74
70 to 104
102 to 136
134 to 160
LENGTH
0.5
0.5
0.5
0.5
0.5
0.5
9”
9”
9”
9”
9”
9”
ASTM SOIL HYDROMETERS
CAT NO
ASTM
GRAVITY RANGE
CAT NO
ASTM
RANGE, GRMS/LITER
8650
8652
151H
152H
.995 to 1.038
-5 to +60
DIV
LENGTH
DIV
LENGTH
0.001
1 g/l
8509
280mm
280mm
BRIX HYDROMETERS
PER CENT SUGAR IN AQUEOUS SOLUTION @20C LENGTH: 275MM TO 330MM.
CAT NO
8698
8700
8698.2
8698.4
8698.8
RANGE
-5 to +5
-1 to 11
0 to 30
0 to 6
6 to 12
DIV
0.1
0.1
0.5
0.1
0.1
CAT NO
8706.8
8708
8708.2
8708.4
8710
RANGE
36
39
42
48
49
to
to
to
to
to
42
51
48
54
61
DIV
0.1
0.1
0.1
0.1
0.1
8504
HYDROMETERS
BRIX HYDROMETERS (CONTINUED)
PER CENT SUGAR IN AQUEOUS SOLUTION @20C LENGTH: 275MM TO 330MM.
CAT NO
8702
8702.2
8702.4
8704
8704.4
8706
8706.2
8706.4
8706.6
RANGE
9 to 21
12 to 18
15 to 25
19 to 31
25 to 35
29 to 41
30 to 36
30 to 60
35 to 45
DIV
CAT NO
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.5
0.1
RANGE
8710.2
8710.4
8712
8712.2
8712.4
8712.6
8714
8716
53
54
59
60
60
66
69
79
to
to
to
to
to
to
to
to
DIV
58
60
71
66
90
72
81
91
0.1
0.1
0.1
0.1
0.5
0.1
0.1
0.1
BRIX THERMOHYDROMETERS
PER CENT SUGAR IN AQUEOUS SOLUTION @20C LENGTH; 305MM TO 386MM.
CAT NO
8748
8750
8748.2
8748.4
8748.6
8752
8752.2
8752.4
8752.6
8754
8754.2
8754.4
8754.6
8756
8756.2
8756.4
8758
8760
8762
8762.2
8764
8766
BRIX RANGE
-5 to +5
-1 to 11
0 to 30
0 to 6
5 to 11
9 to 21
10 to 16
15 to 21
-15 to 25
19 to 31
20 to 26
25 to 31
25 to 35
29 to 41
30 to 45
30 to 60
39 to 51
49 to 61
59 to 71
60 to 90
69 to 81
79 to 91
DIV
0.1
0.1
0.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.5
0.1
0.1
0.1
0.5
0.1
0.1
LENGTH
TEMP RANGE
LENGTH
TEMP RANGE
330mm
330mm
305mm
330mm
330mm
365mm
385mm
330mm
365mm
365mm
385mm
385mm
365mm
365mm
380mm
305mm
365mm
365mm
365mm
305mm
365mm
380mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
50OC
BALLING SCALE THERMOHYDROMETERS
FOR ALCOHOL TESTING. STANDARDIZED @68F (20C)
CAT NO
8770
8772
BALLING RANGE
0 to 32
8 to 25
DIV
0.5
0.5
385mm
385mm
30 to 120OF
30 to 120OF
PROOF SCALE HYDROMETERS
FOR ALCOHOL TESTING. MEET NBS SPECIFICATIONS. STANDARDIZED @60/60F LENGTH 12” PROOF = % ALCOHOL BY VOLUME X 2.
CAT NO
8843.5
8843.6
8843.7
8843.8
8843.9
8844
8845
8846
8847
8848
8850
PROOF RANGE
0 to 20
20 to 40
40 to 60
60 to 80
80 to 100
0 to 100
80 to 120
100 to 140
130 to 170
160 to 200
185 to 206
DIV
0.2
0.2
0.2
0.2
0.2
1.0
0.5
0.5
0.5
0.5
0.2
8752
US CUSTOMS HOUSE HYDROMETERS
DUAL SCALE - PROOF & TRALLES. (TRALLES = % ALCOHOL BY VOLUME)
HYDROMETER
CAT NO
8843
8844
RANGE PROOF
0 to 200
DIV
2.0
RANGE TRALLES
0 to 100
DIV
2.0
LENGTH
12”
Page 77
THERMOHYDROMETER
WITH INTERNAL THERMOMETER, RANGE 0/120F
CAT NO
8860
RANGE PROOF
0 to 200
DIV
RANGE TRALLES
DIV
LENGTH
2.0
DIV
0 to 100
2.0
LENGTH
13”
TRALLES HYDROMETER
TRALLES = % ALCOHOL BY VOLUME @ 60F Not for Wine
CAT NO
8780
8782
8784
8786
8788
8790
8792
TRALLES RANGE
0 to 50%
0 to 100% & Proof
0 to 5%
5 to 10%
10 to 15%
15 to 20%
20 to 25%
0.5%
1.0%
0.1%
0.1%
0.1%
0.1%
0.1%
12”
12”
9”
9”
9”
9”
9”
POUNDS PER U.S. GALLON
USEFUL IN DETERMINING THE ACTUAL WEIGHT OF A KNOWN VOLUME OF FUEL. USED PRINCIPALLY IN AVIATION LOADING APPLICATIONS.
CAT NO
8881
8882
8883
8884
8885
RANGE, LBS./U.S. GAL
5.5
5.4
6.0
6.0
6.5
to
to
to
to
to
7.5
6.3
7.1
6.6
7.1
DIV
.02
.01
.01
.01
.01
LENGTH
12”
12 1/2”
12 1/2”
12 1/2”
12 1/2”
TYPE
OF
FUEL
Full Range
Gasoline
JP-4 & Kerosene
JP-4
Kerosene
JET FUEL TESTING KIT
THERMOHYDROMETER, API SCALE, RANGE 40/75 API, TEMP RANGE 0/130F, LENGTH 190MM FOR USE IN SYRINGE KIT. SCALE IS COLOR CODED AS FOLLOWS:
FROM 40 TO 50 API - WHITE - MARKED KEROSENE
FROM 50 TO 65 API - YELLOW - UNMARKED
FROM 65 TO 75 API - GREEN - MARKED AVGAS
Cat No 700 - Thermohydrometer with syringe kit consisting of rubber bulb, glass cylinder, and BUNAN pickup tube,
Cat No 700-1 - Thermohydrometer only
Cat No 700-2 - Syringe kit as described above, without hydrometer.
SALINITY HYDROMETERS
EXTREMELY SENSITIVE HYDROMETERS FOR DETERMINATION OF SPECIFIC GRAVITY.
CAT NO
8900
8902
8904
RANGE
DIV
1.000 to 1.011
1.010 to 1.021
1.020 to 1.031
.0002
.0002
.0002
LENGTH
9”
9”
9”
8843
SALT HYDROMETERS
PERCENT SATURATION - NACL IN WATER @ 60F
CAT NO
8920
8922
8924
8926
8928
RANGE
DIV
0 to 15%
0 to 40%
40 to 70%
70 to 100%
0 to 100%
.2%
.5%
.5%
.5%
1.0%
LENGTH
12”
13”
12”
12”
12”
PERCENT NACL BY WEIGHT @ 60F
CAT NO
8940
8942
RANGE
0 to 26.5%
0 to 26.5%
DIV
0.5%
0.5% (20/120F)
LENGTH
12”
12”
PERCENT SATURATION CACL IN WATER @ 60F
CAT NO
8945
RANGE
0 to 120
DIV
1.0
LENGTH
12”
8928
HYDROMETERS
PEROXIDE HYDROMETER
IN PLASTIC GRADUATED CYLINDER. PER CENT HYDROGEN PEROXIDE IN WATER @70F
CAT NO
8950
RANGE
0 to 100
DIV
LENGTH
DIV
LENGTH
2.0%
6”
MILK HYDROMETER
CAT NO
8400
8402
8404
8406
8408
8410
RANGE
14 to 42
14 to 42
0 to 120
29 to 35
24 to 37
0 to 120
1
1
1
0.2
.01
1
10.5”
12.5”
12”
6.5”
12”
12”
TYPE
Quevennes
Quevennes - w/-10 to 40C thermometer in stem
Spence Lactometer
Stone Lactometer
Lactometer
Spence Lactometer - w/0 to 120F thermometer
HYDROMETER JARS
HYDROMETER JARS OF RUGGED BOROSILICATE GLASS CONSTRUCTION, FREE FROM MECHANICAL DEFECTS AND INTERNAL STAIN.
HAVE BEEN CHOSEN TO SECURE MAXIMUM STABILITY. THE LISTED DIMENSIONS ARE APPROXIMATE.
CAT NO
F1038200
F1038300
F1038375
F1050375
F1063460
SIZE,
38
38
38
50
63
x
x
x
x
x
MM
200
300
375
375
460
THE FOOT DIAMETERS
WITH POUR OUT SPOUT.
SIZE, INCHES
1.5 x 8
1.5 x 12
1.5 x 15
2 x 15
2.5 x 18
GRADUATED CYLINDERS
CALIBRATED ON THE BASIS OF THE TRUE METRIC LITER. DOUBLE SCALES.
CAT NO
F450050
F450100
F450250
F450500
F4501000
CAPACITY,
50
100
250
500
1000
ML
F450050
8402
SUGGESTIONS
TO ASSURE ACCURATE HYDROMETER READINGS.
1 - BE SURE HYDROMETER IS CLEAN AND DRY.
2 - SMOOTH CLEAR CYLINDER OR JAR FOR LIQUID TESTED; SHOULD BE DRY OR WELL RINSED
WITH PORTION OF SAMPLE.
3 - SAMPLE MUST BE THOROUGHLY MIXED BEFORE TESTING. PREFERABLY BY A STIRRER
WHICH REACHES BOTTOM OF SAMPLE CONTAINER.
4 - IMMERSE HYDROMETER SLOWLY IN LIQUID TO A POINT BELOW WHICH IT NATURALLY
SINKS (NOT OVER 1/8”)
5 - DO NOT MAKE READING TILL THE HYDROMETER AND LIQUID ARE AT REST AND
FREE FROM AIR BUBBLES.
6 - THE TEMPERATURES OF THE HYDROMETER AND LIQUID TESTED SHOULD BE EQUAL.
7 - MORE ACCURATE READINGS RESULT WHEN THE TEMPERATURE OF THE LIQUID APPROACHES
THAT OF THE SURROUNDING ATMOSPHERE. WHEN DIFFERENCES OF TEMPERATURE ARE
NECESSARY AND VARY FROM THE STANDARD, THE READING CAN BE APPROXIMATED BY USE
OF CORRECTED TABLES.
8 - SURFACE TENSION OF THE LIQUID AFFECTS HYDROMETER OBSERVATIONS. THE LIQUID FOR
WHICH A HYDROMETER IS INTENDED MUST BE SPECIFIED SINCE IT WILL INDICATE
DIFFERENTLY IN TWO LIQUIDS HAVING THE SAME DENSITY BUT DIFFERENT
9 - HYDROMETERS OF EQUIVALENT DIMENSIONS MAY BE COMPARED WITH EACH OTHER EVEN
IF
THE LIQUID USED DIFFERS IN SURFACE TENSION FROM THE SPECIFIED LIQUID, BUT
COMPARISONS OF DISSIMILAR INSTRUMENTS, IN SUCH A LIQUID, MUST BE CORRECTED FOR
THE EFFECT OF SURFACE TENSION.
10 - TO AVOID ERRORS DUE TO SPONTANEOUS CHANGES IN SURFACE TENSION SKIMMING AND
FORMATION OF SURFACE FILMS OF IMPURITIES FROM APPARATUS, LIQUID OR AIR,
OVERFLOW THE CYLINDER IMMEDIATELY BEFORE TAKING THE READING.
11 - TO READ THE HYDROMETER BRING THE EYE, PREFERABLY FROM BELOW, TO THE LEVEL OF
THE PLANE SURFACE OF THE LIQUID. READ THE POINT WHERE THE SCALE IS CUT BY THE
SURFACE LINE.
12 - ERRORS OF PARALLAX WHEN READING THERMOMETER SCALE CAN BE AVOIDED BY
ALIGNING THE NEAR END OF THE MERCURY COLUMN. THE PORTIONS ON EITHER SIDE OF
THE STEM AND THOSE SEEN THROUGH THE CAPILLARY SO THEY APPEAR TO BE A STRAIGHT
LINE.
WHEN THE EYE IS IN THIS POSITION THE LINE OF SIGHT IS NORMAL TO THE STEM.
* CONDENSED LARGELY FROM BUREAU OF STANDARDS CIRCULAR NO. 16.
SURFACE TENSIONS.
Page 79
BIMETAL
THERMOMETERS
Page 81
LABORATORY AND GENERAL TEST THERMOMETERS
1 3/4” AND 2” DIAL SIZE
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
Models GT-100R & LT-225R easy to recalibrate using wrench on hex surface on back of dial.
Type 304 stainless steel in stem and case.
Head diameter: GT-100R 1.75”; LT-225R 2”.
Stem diameter: .150 Standard; GT-100R available .142, LT-225R Series available .187.
Corrosion resistant to most chemicals.
Rustproof - Dustproof - Leakproof - Hermetically sealed.
Bi-metallic element dampened with silicone for minimum pointer
vibration and maximum heat transfer.
Adjustable clamp for tank and tray mounting.
Guaranteed accurate within 1/2 of 1% around entire dial range.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Durable - non-fragile - safe to handle.
o
o
Over range protection is 50% up to 500 F and 10% over 500 F.
STANDARD DIALo RANGES
FAHRENHEIT
/DIV
CENTIGRADE
o
o
o
-100 to 100
2
-50 to 100
o
o
-40 to 160
2
o
o
o
0 to 140
2
-10 to 110
o
o
o
0 to 180
2
**0 to 50
o
o
o
0 to 220
2
0 to 100
o
o
o
*25 to 125
1
0 to 150
o
o
20 to 240
2
o
o
o
50 to 250
2
0 to 250
o
o
o
50 to 300
2
0 to 300
o
o
o
50 to 400
5
100 to 400
o
o
50 to 500
5
o
o
150 to 750
10
o
o
*200 to 1000
10
O
* NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F.
Model LT-225R
DIV
o
1
o
1
o
1/2
o
1
o
1
o
2
o
5
o
5
Model GT-100R
1 3/4” AND 2” SIZE
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
Model LN-250R easy to recalibrate by loosening a socket head
screw above hex connecting nut.
Model numbered GT-200 supplied without recalibration device.
Connection Nut: 1/4” N.P.T. standard, other sizes available at extra charge.
Type 304 stainless steel in stem and case.
All welded construction.
Head diameter: GT-200 1 3/4”; LN-250 Series 2”.
Rustproof - Dustproof - Leakproof - Hermetically sealed.
Stem diameter: LN-250R 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”,
including threads. Available in stem lengths up to 72”.
GT-200: Standard stem length 2 1/2”, 4”, 6”. Available 8”, 12”, 18”.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Bi-metallic element dampened with silicone for minimum pointer
vibration and maximum heat transfer
Guaranteed accurate with 1% around entire dial range.
o
o
over-range protection 50% up to 500 F, 10% above 500 F.
STANDARD DIALo RANGES
FAHRENHEIT
/DIV
CENTIGRADE
o
o
o
-100 to 100
2
-50 to 100
o
o
o
-40 to 160
2
-50 to 25
o
o
o
0 to 140
2
-10 to 110
o
o
o
0 to 180
2
**0 to 50
o
o
o
0 to 220
2
0 to 100
o
o
o
25 to 125
1
0 to 150
o
o
20 to 240
2
o
o
o
50 to 250
2
0 to 250
o
o
o
50 to 300
2
0 to 300
o
o
o
50 to 400
5
100 to 400
o
o
50 to 500
5
o
o
150 to 750
10
o
o
*200 to 1000
10
O
* NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F.
DIV
o
1
o
1
o
1
o
1/2
o
1
o
1
BIMETAL THERMOMETERS
BACK CONNECTED INDUSTRIAL THERMOMETERS
Model GT-200
o
2
o
5
o
5
Model LN-250R
Page 83
BACK CONNECTED INDUSTRIAL THERMOMETERS
AVAILABLE IN 3” AND 5” DIAL SIZES
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
Model GT-300R
Model GT-500R
18-8 Type 304 stainless steel.
Model numbered GT-300R and GT-500R easy to recalibrate with Hex Screw.
Connection Nut: 1/2” N.P.T. standard, can be supplied
in other sizes at extra charge.
Anti-Parallax dial avoids reading errors. White dial with large Black numbers
and graduations on raised ring for surest, sharpest, easiest readability.
All welded construction.
Head diameters: 3” and 5”.
Rustproof - Dustproof - Leakproof - Hermetically sealed.
Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”,
including threads. Available in stem lengths up to 72”.
Extra-heavy glass crystal. Plastic or tempered crystal can
be supplied at extra charge.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Bi-metallic element dampened with silicone for minimum pointer
vibration and maximum heat transfer.
Guaranteed accurate with 1% around entire dial range.
o
o
Over-range protection 50% up to 500 F, 10% above 500 F.
STANDARD DIALo RANGES
FAHRENHEIT
/DIV
CENTIGRADE
o
o
o
-100 to 100
2
-50 to 100
o
o
o
-40 to 160
2
-50 to 25
o
o
o
0 to 140
2
-10 to 110
o
o
o
0 to 180
2
**0 to 50
o
o
o
0 to 220
2
0 to 100
o
o
o
25 to 125
1
0 to 150
o
o
20 to 240
2
o
o
o
50 to 250
2
0 to 250
o
o
o
50 to 300
2
0 to 300
o
o
o
50 to 400
5
100 to 400
o
o
50 to 500
5
o
o
150 to 750
10
o
o
*200 to 1000
10
O
* NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F.
Special Dial Ranges and Stem Lengths Available at Extra Charge.
DIV
o
1
o
1
o
1
o
1/2
o
1
o
1
o
2
o
5
o
5
AVAILABLE IN 3” AND 5” DIAL SIZES
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
18-8 Type 304 stainless steel.
Model numbered BC350R and BC550R easy to recalibrate with Hex Screw.
Connection Nut: 1/2” N.P.T. standard, can be supplied
in other sizes at extra charge.
Anti-Parallax dial avoids reading errors. White dial with large Black numbers
and graduations on raised ring for surest, sharpest, easiest readability.
All welded construction.
Head diameters: 3” and 5”.
Rustproof - Dustproof - Leakproof - Hermetically sealed.
Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”,
including threads. Available in stem lengths up to 72”.
Extra-heavy glass crystal. Plastic or tempered crystal can
be supplied at extra charge.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Bi-metallic element dampened with silicone for minimum pointer
vibration and maximum heat transfer.
Guaranteed accurate with 1% around entire dial range.
o
o
Over-range protection 50% up to 500 F, 10% above 500 F.
STANDARD DIALo RANGES
FAHRENHEIT
/DIV
CENTIGRADE
o
o
o
-100 to 100
2
-50 to 100
o
o
o
-40 to 160
2
-50 to 25
o
o
o
0 to 140
2
-10 to 110
o
o
o
0 to 180
2
**0 to 50
o
o
o
0 to 220
2
0 to 100
o
o
o
25 to 125
1
0 to 150
o
o
20 to 240
2
o
o
o
50 to 250
2
0 to 250
o
o
o
50 to 300
2
0 to 300
o
o
o
50 to 400
5
100 to 400
o
o
50 to 500
5
o
o
150 to 750
10
o
o
*200 to 1000
10
O
* NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F.
Special Dial Ranges and Stem Lengths Available at Extra Charge.
BIMETAL THERMOMETERS
BOTTOM CONNECTED INDUSTRIAL THERMOMETERS
Model BC-350R
DIV
o
1
o
1
o
1
o
1/2
o
1
o
1
o
2
o
5
o
5
Model BC-550R
Page 85
ADJUSTABLE ANGLE INDUSTRIAL THERMOMETERS
AVAILABLE IN 3” AND 5” DIAL SIZES
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
18-8 Type 304 stainless steel.
Model numbered AA-375R and AA-575R easy to
recalibrate with Hex Screw.
Connection Nut: 1/2” N.P.T. standard, can be supplied
in other sizes at extra charge.
Anti-Parallax dial avoids reading errors. White dial with large Black
numbers and graduations on raised ring for surest,
sharpest, easiest readability.
All welded construction.
Head diameters: 3” and 5”.
Rustproof - Dustproof - Leakproof - Hermetically sealed.
Stem diameter: 1/4”. Standard stem lengths:
2 1/2”, 4”, 6”, 9”, 12”, 18”, 24”,
including threads. Available in stem lengths up to 72”.
Extra-heavy glass crystal. Plastic or tempered crystal can
be supplied at extra charge.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Bi-metallic element dampened with silicone for minimum pointer
vibration and maximum heat transfer.
Guaranteed accurate with 1% around entire dial range.
o
o
Over-range protection 50% up to 500 F, 10% above 500 F.
STANDARD DIALo RANGES
FAHRENHEIT
/DIV
CENTIGRADE
o
o
o
-100 to 100
2
-50 to 100
o
o
o
-40 to 160
2
-50 to 25
o
o
o
0 to 140
2
-10 to 110
o
o
o
0 to 180
2
**0 to 50
o
o
o
0 to 220
2
0 to 100
o
o
o
25 to 125
1
0 to 150
o
o
20 to 240
2
o
o
o
50 to 250
2
0 to 250
o
o
o
50 to 300
2
0 to 300
o
o
o
50 to 400
5
100 to 400
o
o
50 to 500
5
o
o
150 to 750
10
o
o
*200 to 1000
10
O
* NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800 F.
Special Dial Ranges and Stem Lengths Available at Extra Charge.
IMMERSE STEM AT LEAST 2” IN LIQUIDS, 4” IN GASES
DIV
o
1
o
1
o
1
o
1/2
o
1
o
1
o
2
o
5
o
5
BIMETAL THERMOMETERS
SPECIAL USE DIAL THERMOMETERS
MODEL MX325
Recalibrator
The red manually operated reset pointer is turned by the center knob against
either the high or low side of the permanent indicating pointer.
MODEL PT50R
The manual reset pointer will move up or down the range remaining at maximum
or minimum temperature reading. At a glance gives present temperature together
with maximum or minimum temperature since last reset. Avoid uses subject to
excessive vibration.
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
18-8 Type 304 stainless steel construction.
Corrosion resistant to most chemicals.
Rustproof - Dustproof - Leakproof.
Head diameter 1” - Stem 5” long by .150” diameter.
White dial with large numbers and graduations easy to read from any angle.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Bi-metallic element dampened with silicone for minimum pointer
vibration and maximum heat transfer.
Guaranteed accurate within 1/2 of 1% around dial range.
Durable - Non-Fragile - Safe to Handle.
o
o
Over range protection is 50% up to 500 F, and 10% over 500 F.
Lucite unbreakable crystal - no glass to break.
o
Glass crystal used for temperatures over 220 F.
Available Fahrenheit or Centigrade.
Hard rubber carrying case with attached pencil clip.
Hermetically Sealed.
FEATURES
•
•
•
•
•
•
•
•
•
•
•
STANDARD DIALo RANGES
FAHRENHEIT
o
25 to 125
o
-40 to 160
o
0 to 220
o
50 to 500
/DIV
o
1
o
2
o
2
o
5
CENTIGRADE
o
0 to 150
o
0 to 250
o
-10 to 110
DIV
o
1
o
2
o
1
•
•
18-8 Type 304 stainless steel.
All welded construction.
Model MX 325R easy to recalibrate by loosening 3 screws on back.
Anti-Parallax dial avoids reading errors. White dial with large,
black numbers and graduations on raised ring for surest,
sharpest, easiest readability.
Head diameter 3”.
Rustproof - Dustproof - Leakproof.
Connection Nut: 1/2” N.P.T. standard, can be supplied in
other sizes at extra charge.
Stem diameter: 1/4”. Standard stem lengths: 2 1/2”, 4”, 6”, 9”,
12”, 18”, 24”, including threads.
Available in stem lengths up to 72”.
Actuated by super-sensitive bi-metallic Helix Coil - No Liquids.
Bi-metallic element dampened with silicone for minimum
pointer vibration and maximum heat transfer.
Normal temperature indication accurate within 1% around entire
dial range. Max. or Min. temperature indication
accurate within 1 1/2%
o
o
over-range protection 50% up to 500 F, 10% above 500 F.
Extra-heavy glass crystal. Plastic or tempered crystal can be
supplied at extra charge.
Page 87
SURFACE TEMPERATURE BIMETAL DIAL THERMOMETERS
2” DIAMETER DUAL MAGNET SURFACE TEMPERATURE THERMOMETERS ARE DESIGNED TO MEASURE TEMPERATURES OF MANY
DIFFERENT SURFACES. THE BASE OF THE UNIT IS PLACED ON THE SURFACE TO BE MEASURED. THE SENSING ELEMENT THEN DIRECTLY
CONTACTS THE SURFACE; EXPANSION OR CONTRACTION OF THE BIMETAL ELEMENT RESULTS IN DIAL READOUT.
HEIGHT: 1/2” ACCURACY: +/-2% FULL SCALE RANGE.
CAT NO
312F
313F
314F
315F
330F
TEMP RANGE, FAHRENHEIT
CAT NO
0 to 250OF
0 to 500OF
50 to 750OF
0 to 150OF
-110 to 160OF
TEMP RANGE, CELSIUS
312C
313C
314C
315C
330C
-20 to 120OC
-20 to 250OC
10 to 400OC
-20 to 65OC
-70 to 70OC
RANGES AND ORDERING INFORMATION
STANDARD DIAL RANGES
FAHRENHEIT
º/DIV
CENTIGRADE
º/DIV
2º
-75 to 175º (B)
5º
-40 to 160º
2º
-50 to 100º
1º
0 to 140º2º
-50 to 25º
1º
0 to 180º2º
-10 to 110º (a)
1º
0 to 220º (a)
2º
0 to 50º
1/2º
20 to 240º
2º
0 to 100º
1º
25 to 125º (a)
1º
0 to 150º (a)
1º
50 to 250º
2º
0 to 200º
2º
50 to 300º
2º
0 to 250º (a)
2º
50 to 400º
5º
0 to 300º
5º
50 to 500º (a)
5º
100 to 400º
5º
150 to 750º
10º
*200 to 1000º
10º
-100 to 100º
* NOT RECOMMENDED FOR CONTINUOUS USE ABOVE 800ºF.
(a) MODEL PT-50 AVAILABLE IN THESE RANGES ONLY.
(b) 3” INDUSTRIAL SIZE ONLY.
ORDERING INSTRUCTIONS
Create catalog number by combining the following:
(Model No.) + (Top Range of Thermometer) +
(‘F’ or ‘C’) + (Stem Length)
Example: GT100R 50 to 500F 8 in. Stem
(GT100R) + (500) + (F) = (8) = GT100R500F8
Example: BC350R 0 to 140F 2-1/2 (2.5”) in. Stem
(BC350R) + (140) + (F) = (2.5) = BC350R140F2
*BE SURE TO SPECIFY ANY UNUSUAL APPLICATION SUCH AS OVERRANGE, HIGH PRESSURE OR CORROSIVE CONDITIONS. GIVE DETAILS.
* IF HEAD IS TO BE SUBJECTED TO TEMPERATURES IN EXCESS OF 300F, STATE TEMPERATURE.
Special Quotation on Request for:
•Special stem lengths
•Plastic crystals (standard on PT50R, GT100R, LT225R)
•Special connection nut sizes.
•
•
•
•
Designed and manufactured to assure a perfect alignment of
thermometer and sensing element.
Industry Standard will fit the thermometers of all manufacturers.
Machined from solid bar stock-304 Stainless steel.
high quality of material and workmanship.
STANDARD THERMOWELL
THERMOMETER
STEM LENGTH
THERMOWELL #
304 SS 3/4” NTP
2 1/2”
4”
6”
9”
12”
18”
24”
36”
TW02.5
TW04
TW06
TW09
TW12
TW18
TW24
TW36
BIMETAL THERMOMETERS
BIMETAL DIAL THERMOMETER WELLS
BUSHINGS FOR THERMOWELLS
Page 89
COMMENTARY
Page 91
THE
NON-MERCURIAL THERMOMETERS:
JUST
HOW
GOOD
ARE THEY?
Spirit thermometers, whether alcohol or mineral spirit filled, have a reputation for being inaccurate which is not entirely
deserved. Excellent accuracy and repeatability can be obtained with spirit thermometers provided the manufacturer
recognizes the differing characteristics of the media - and how each differs from mercury - and adjusts his
manufacturing and calibration procedures accordingly.
liquid column ends. Performing this
equipment needed and that the traditional
procedure over a series of temperatures
acid etching procedure for marking the glass
results in a series of reference marks on the
be utilized. It would be virtually impossible
Firstly, the media: the terms ‘alcohol’
thermometer stem which allows definition
for a high volume producer who uses decals
and ‘mineral spirits’ (as well as toloul,
and placement of the graduations which
and/or silk screening procedures for his ther-
butanol and pentane) are often referred to
make up the scale. Let us suppose the
mometer markings to produce
simply as ‘spirit’ with little or no distinction.
example of a -10/250C range thermometer.
thermometers of this caliber.
Each material, however, has different
De facto industry standardsfor a mercury
characteristics and is appropriate for
thermometer would suggest defining the
differing temperature applications. In our
‘points’ of 0 and 200C; by interpolation
opinion, alcohol is an excellent medium for
and extrapolation a graduated scale can be
low temperature applications within the
devised which will yield satisfactory
temperature limits of approximately -100C
accuracy assuming:
to +50C. We use butanol for temperatures
1) a linear curve of expansion (mercury is
A weakness, even of well-designed and well-
below -100C down to approximately -200C.
very linear) and
made non-mercurial thermometers, relates to
We discontinued the use of Tuloul and
2) a perfectly uniform capillary tubing
those designed for partial
Tolune altogether a number of years ago
within the thermometer.
immersion. Since the volume of the
EXACTLY WHAT IS....
SPIRIT?
capillary must be somewhat larger than that
when these items were placed on the
of a similar mercury thermometer, there is
suspected carcinogen list. Mineral spirits
have a workable range from -30C to +200C
under normal circumstances and up to
SO WHAT ARE THE
NEGATIVES TO
CONSIDER?
MULTIPLE CALIBRATION
POINTS ARE NEEDED
more liquid exposed to ambient
temperatures which can vary widely. The
influence of this ambient temperature can
250C if correctly pressurized.
KESSLER has always been cautious on
affect the indication of the thermometer, per-
Secondly, cleanliness: Thermometers
assumptions which affect the accuracy of
haps markedly. Partial immersion
in general must be CLEAN to function well
the instrument. Accordingly our
thermometers are calibrated anticipat-
and have a long, accurate life. Clean in this
procedures call for three, not two,
ing indoor, climate controlled conditions
context means not just the absence of dirt
calibrations points on a -10/250C mercury
(25C (77F) is often cited as the standard).
and visible impurities but also the absence
thermometer.
Consider that partial immersion thermometer
being used for outdoor testing during a frigid
of moisture and oxygen in the sealed instru-
Alaskan winter or during midday in July in
ment.
SPECIALIZED GRADUATING
EQUIPMENT IS A MUST
CALIBRATION
(CHARTING
IS OF
PARAMOUNT IMPORTANCE
ation for ALL partial immersion thermometers;
‘spirit’ thermometers are simply more sensi-
THE CURVE
OF EXPANSION OF THE MEDIUM)
Arizona. Conditions of use are a consider-
A mineral spirits thermometer is entirely
tive to changes in ambient temperatures that
another challenge. We have determined
their mercury
that in order to obtain acceptable accuracy,
counterparts.
Thirdly, proper calibration: Let me
we must calibrate this thermometer at 0, 50,
use an illustration. Calibration in this
100, 150, 200 and 250C; spacing of the
context means to subject an ungraduated
graduations changes somewhat between
thermometer to a known, carefully
each pair of points, while adjusting for the
controlled temperature under correct
non-linear expansion curve of the medium.
conditions of immersion, allow it to come to
This type of adjusted spacing requires that
equilibrium and mark the stem where the
the manufacturer has the graduating
HOW ABOUT
SEPARATIONS IN THE COL-
Partial Immersion:
The second downside to spirit thermometers
+/- one scale division low scale.
is the tendency for the liquid column to
separate. This separation of the liquid
+/- 1.5 scale division high scale
column is a condition and NOT a defect.
Separations occur primarily in shipping or
ie. on a -10/250C partial immersion
when stored for long periods of time in a
thermometer we would call 0 degrees low
horizontal position. The preferred storage
scale, 125 degrees mid scale, 250C high
mode is in a vertical position (such as in our
scale.
thermometer rack) when not in use.
Complete instructions for rejoining
separations are included with all KESSLER
COMMENTARY
UMN?
FOR TECHNICAL INFORMATION PLEASE CONSULT FACTORY.
thermometers; as ever, if you experience difficulty, please phone us for no charge technical service.
HOW ABOUT RESPONSE
TIME?
A third (potentially negative) characteristic to
consider is response time. Typically
non-mercurial thermometers take longer
to come to equilibrium than their mercury
counterparts, normally by a factor of approximately 50%. While this is not
significant is most applications, certain
procedures which require an extremely quick
response time (such as a melt point index)
may not be good candidates for use of a
non-mercurial thermometer.
It is in consideration of all above concerns
that KESSLER has defined the following
accuracy requirements for our
non-mercurial thermometers:
Total Immersion:
+/- one scale division, full scale.
Page 93
For more information, please contact us:
ExpotechUSA
10700 Rockley Road
Houston, Texas 77099
USA
281-496-0900 [voice]
281-496-0400 [fax]
E-mail: sales@expotechusa.com
Website: www.ExpotechUSA.com
Download