Thermotech underfloor heating system Mixing unit TMix® XS Advantages • Compact • Fully assembled upon delivery • Suitable for small areas such as bathrooms and hallways • C an be supplied with immersion heater to keep the floor surface warm when the ordinary source of heat is turned off Product properties Specifications Product ID 510XX Width/depth/height 330/80/250 mm Air vent Manual Connections Couplings, underfloor heating Couplings to source of heating 17*2 Cu15 Immersion heater 350 W/230 V Bars Stainless steel 1.4301 (X5CrNi8-10) Ri25 Coupling accessories Product ID 8 mm 1 loop.................................................. 62221 8 mm 2 loops.............................................. 62222 8 mm 4 loops.............................................. 62224 Plug 8 mm..................................................... 62225 12-mm coupling......................................... 50000-12 16-mm coupling........................................ 50000-16 20-mm coupling....................................... 50000-20 Thermotech TMix® XS is a fully assembled, compact mixing unit intended for small areas such as bathrooms and hallways. It is designed for connection of a maximum of 4 loops for size 8 mm, alternatively one loop for sizes 12, 16, 17 or 20 mm. The mixing unit can be ordered in six different configurations depending on the preferred type of control. Three of the packages include a 350-W immersion heater that maintains a comfortable floor temperature for clinker floor surfaces up to a maximum of 12 m2 (29 W/m2), during the months of the year when the ordinary source of heat is turned off. TMix® XS is delivered fully assembled and equipped with: • Circulation pump with cable and plug • Thermostat valve • Couplings for underfloor heating pipes, 17 x 2 mm pipes • Couplings to primary source of heating, Cu15 • Manual air vent Capacity At 50 W/m2 and 5°C (**7°C) temperature drop. Specified lengths refer to longest loop. Applies to all versions. 8 x 1 mm pipe - **32 m loops/approx. 16 m2 12 x 2 mm pipe - **40 m loop/approx. 8 m2 16 x 2 mm pipe – 70 m loop/approx. 14 m2 17 x 2 mm pipe – 70 m loop/approx. 14 m2 20 x 2 mm pipe – 70 m loop/approx. 14 m2 • Control alternatives In addition to the equipment above, the TMix® XS with a 350-W immersion heater is also equipped with: • Immersion heater, 350 W • Safety valve, 4 bar IG500-1312 Thermotech Company Group Phone: +46 (0)620 68 33 30, www.thermotech.eu Thermotech Scandinavia AB fulfils the ISO standards for quality- and environment management. Certifierad ISO 9001 ISO 14001 1(4) Thermotech underfloor heating system Installation guide Thermotech TMix® XS mixing unit Remember Configuration The mixing unit is intended for connection to two-pipe systems and cannot be connected to single-pipe heating systems. For single-pipe systems, mixing unit TMix® S is recommended. The mixing unit in its basic configuration is equipped with a hand knob on the two-way valve and the appropriate control package is chosen from the table to the left. Optimal function and easy deaeration is achieved by letting the mixing unit constitute the system's highest point. 2 3 1 Mixing unit packages The TMix® XS is ordered as a pre-assembled package based on the preferred control alternative. For detailed information see the following page. Model Prod. ID* Control TMix® XS Standard 51011 Thermostatic head with air sensor 6–28°C TMix® XS Standard with 350-W immersion heater 51012 TMix® XS EC 51021 TMix® XS EC with 350-W immersion heater 51022 TMix® XS ICR 51031 TMix® XS ICR Incl. immersion heater and control unit with summer and winter switch 51032 5 4 4 5 TMix® XS The basic model of the TMix® XS mixing unit includes the following components: 1. Circulation pump with cable and wall plug Electronic control with actuator and wired room thermostat, and control unit Electronic control with actuator and wireless room thermostat, and control unit. 2. Thermostat valve G15 3. Manual air vent 4. Couplings for 17 x 2 mm underfloor heating pipe 5. Couplings,Cu15 6 7 Primary flow and return Connection 2 3 1 TMix® XS with immersion heater The following components are for the TMix® XS with a 350W immersion heater: 6. Immersion heater, 350 W/230 V Primary circulation pump 7. Safety valve, 4 bar 2(4) Switching from left to right connection The TMix® XS is delivered with the couplings on the right as standard. To move the couplings to the left, the mixing unit is disconnected from the brackets and turned. If an immersion heater is installed, the safety valve must be turned so that it points outwards. Thermotech underfloor heating system Installation guide Thermotech TMix® XS mixing unit Information about control alternatives To control the mixing unit when connecting to an external heat source, the TMix® XS is equipped with one of the following control units: TMix® XS Standard TMix® XS EC TMix® XS ICR Control Included components Thermostatic head with air sensor 6–28°C (51904) MATERIAL NAME DRAWN BY APPV'D BY MATERIAL WEIGHT DATE DATE Actuator (67034) Adapter (67028) Wired room thermostat (67210) Wired control unit with transformer (67412) 2013-09-13 1 of 1 SCALE 1:3 PROJECT +46620-683330 TITLE DWG NO. A3 REVISION Spårvägen 8 901 31 Umeå Sweden SHEET REVISION Spårvägen 8 901 31 Umeå Sweden 2013-09-13 WEIGHT NAME DRAWN BY • • • • SHEET 1 of 1 SCALE 1:3 PROJECT +46620-683330 TITLE DWG NO. A3 APPV'D BY Product ID 67441-1 includes the following: • Actuator (67033) • Adapter (67028) • Wireless control unit (67441-0) • Wireless room thermostat (67240)* *Can be changed for wireless display thermostat (67280). Heat source regulation Thermostatic head with a twoway valve regulates the room temperature. A wired room thermostat regulates the room temperature via an actuator on the two-way valve. A wireless room thermostat regulates the room temperature via an actuator on the two-way valve. Electric boiler regulation The immersion heater has an integrated thermostat that constantly maintains the floor temperature.* The immersion heater has an integrated thermostat that constantly maintains the floor temperature.* The immersion heater has an integrated thermostat that constantly maintains the floor temperature.* The thermostat does not control the immersion heater. The thermostat regulates the maximum room temperature. The thermostatic head does not control the immersion heater. Electric boiler/ heat source switching Switching is performed manually. Switching via switch on control unit. Heat source mode: The thermostatic head/thermostat controls the room temperature. Electric boiler mode: The thermostatic head/thermostat is set to the minimum position and the immersion heater's integrated thermostat constantly maintains the floor temperature.* Heat source mode: A wireless room thermostat regulates the room temperature. The immersion heater is turned off. Immersion heater mode: The immersion heater has an inteThe immersion heater is only activated if the water temperature falls be- grated thermostat that constantly maintains the floor temperature.* The low 25°C. If there is a risk of this occurring during the winter months, the immersion thermostat regulates the maximum room temperature. heater's plug should be pulled out of the wall outlet. No connection to heat source. Immersion heater, 350 W Noise The purpose of the immersion heater is to maintain a comfortable floor temperature for surfaces up to 12 m2 (29 W/ m2). The TMix® XS with an immersion heater can also be used for heating surfaces up to 7 m2 (50 W/m2). Thermotech's mixing units are equipped with circulation pumps of high quality. Despite this, the pumps are not completely quiet during operation. * The TMix® XS with an immersion heater is intended for clinker floors and maintains an average floor temperature of 25 ± 1.5°C. NB: The temperature above cannot be regulated. The specified temperatures apply to heating loops embedded in concrete with maximum c/c spacing of 200 mm. The lowest possible noise level is attained by having a properly deaerated underfloor heating system and a correctly dimensioned pump. Equipment with circulation pumps should not be installed close to areas that are especially sensitive to noise, such as bedrooms. 3(4) M D A Thermotech underfloor heating system Installation guide Thermotech TMix® XS mixing unit Heat conducting medium Thermostatic valve (3) Drinking water should be used as the heat conducting medium and normally does not require treatment. If there is risk for freezing, an anti-freeze agent must be added when the system is filled. The integrated mixing unit is equipped with a DN15 thermostat valve. A fully open valve has a capacity value of 1.1. The valve can be used with thermostatic heads, with air sensors or electric actuators. Follow the respective manufacturers' instructions for correct mixture of the anti-freeze agent in the heat conducting medium. We recommend however, a mixture with no more than 30% glycol. Higher percentages can damage the heating system's components. Installation of actuator 67034 requires an adapter ring (product ID 67028). It is important that all included system components are oxygen-diffusion tight. Oxygen encroachment can lead to corrosion in the heating system and deposits in the heat conducting medium, damaging moving system components. The circulation pump has seven selectable speeds that are chosen using the knob above the pump housing. The choice of speed depends on system-specific properties. We recommend speed 2 or 3 as a basic setting. Circulation pump Lowara EBV 15-1/65 SC The TMix® XS can be installed on or in walls. The following recommendations apply: • Do not install the mixing unit directly adjoining bedrooms. • The mixing unit must not have direct contact with the concrete slab via metal constructions. • Firmly secure the mixing unit. Ensure that the mixing unit is installed on a stable structural construction so that vibrations and problems with noise do not occur. The mixing unit must be installed with the pump's motor shaft horizontal. Once the mixing unit and the underfloor heating loops are installed, the system must be filled. Fill the mixing unit with water from the heating system and start the mixing unit's pump. Now deaerate using the manual air vent. NB: Take care in shutting the air vent once the air has been removed from the system. Leakage test Applicable rules and instructions are described in the documentation for pressure and leakage tests that accompany the underfloor heating delivery. The documentation can also be downloaded at www.thermotech.eu. Dimensions 78 80 316 320 140 140 60 60 250 250 70 70 4(4) UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: TOLERANCES: LINEAR: ANGULAR: FINISH: DEBUR AND BREAK SHARP EDGES DO NOT SCALE DRAWING REVISION A-01 We reserve the right to change products without prior notice. Please refer to www.thermotech.se for the latest versions of products and installation instructions. Any prices shown exclude VAT unless otherwise stated. No liability is accepted for any typographical errors. Filling and deaeration Installation