Thermotech underfloor heating system
Mixing unit TMix® XS
Advantages
• Compact
• Fully assembled upon delivery
• Suitable for small areas such as bathrooms and
hallways
• C
an be supplied with immersion heater to keep the
floor surface warm when the ordinary source of heat
is turned off
Product properties
Specifications
Product ID
510XX
Width/depth/height 330/80/250 mm
Air vent
Manual
Connections
Couplings, underfloor heating
Couplings to source of heating
17*2
Cu15
Immersion heater
350 W/230 V
Bars
Stainless steel 1.4301
(X5CrNi8-10) Ri25
Coupling accessories
Product ID
8 mm 1 loop.................................................. 62221
8 mm 2 loops.............................................. 62222
8 mm 4 loops.............................................. 62224
Plug 8 mm..................................................... 62225
12-mm coupling......................................... 50000-12
16-mm coupling........................................ 50000-16
20-mm coupling....................................... 50000-20
Thermotech TMix® XS is a fully assembled, compact mixing
unit intended for small areas such as bathrooms and hallways. It is designed for connection of a maximum of 4 loops
for size 8 mm, alternatively one loop for sizes 12, 16, 17 or
20 mm.
The mixing unit can be ordered in six different configurations depending on the preferred type of control. Three
of the packages include a 350-W immersion heater that
maintains a comfortable floor temperature for clinker floor
surfaces up to a maximum of 12 m2 (29 W/m2), during the
months of the year when the ordinary source of heat is turned off.
TMix® XS is delivered fully assembled and equipped with:
• Circulation pump with cable and plug
• Thermostat valve
• Couplings for underfloor heating pipes, 17 x 2 mm pipes
• Couplings to primary source of heating, Cu15
• Manual air vent
Capacity
At 50 W/m2 and 5°C (**7°C) temperature drop. Specified
lengths refer to longest loop. Applies to all versions.
8 x 1 mm pipe - **32 m loops/approx. 16 m2
12 x 2 mm pipe - **40 m loop/approx. 8 m2
16 x 2 mm pipe – 70 m loop/approx. 14 m2
17 x 2 mm pipe – 70 m loop/approx. 14 m2
20 x 2 mm pipe – 70 m loop/approx. 14 m2
• Control alternatives
In addition to the equipment above, the TMix® XS with a
350-W immersion heater is also equipped with:
• Immersion heater, 350 W
• Safety valve, 4 bar
IG500-1312
Thermotech Company Group
Phone: +46 (0)620 68 33 30, www.thermotech.eu
Thermotech Scandinavia AB fulfils the ISO standards for quality- and environment management.
Certifierad
ISO 9001
ISO 14001
1(4)
Thermotech underfloor heating system
Installation guide Thermotech TMix® XS mixing unit
Remember
Configuration
The mixing unit is intended for connection to two-pipe
systems and cannot be connected to single-pipe heating
systems. For single-pipe systems, mixing unit TMix® S is
recommended.
The mixing unit in its basic configuration is equipped with a
hand knob on the two-way valve and the appropriate control
package is chosen from the table to the left.
Optimal function and easy deaeration is achieved by letting
the mixing unit constitute the system's highest point.
2
3
1
Mixing unit packages
The TMix® XS is ordered as a pre-assembled package based
on the preferred control alternative. For detailed information see the following page.
Model
Prod.
ID*
Control
TMix® XS
Standard
51011
Thermostatic head with air
sensor 6–28°C
TMix® XS Standard with 350-W
immersion
heater
51012
TMix® XS EC
51021
TMix® XS EC with
350-W immersion heater
51022
TMix® XS ICR
51031
TMix® XS ICR
Incl. immersion
heater and
control unit with
summer and winter switch
51032
5
4
4
5
TMix® XS
The basic model of the TMix® XS mixing unit includes the
following components:
1. Circulation pump with cable and wall plug
Electronic control with actuator and wired room thermostat, and control unit
Electronic control with actuator and wireless room thermostat, and control unit.
2. Thermostat valve G15
3. Manual air vent
4. Couplings for 17 x 2 mm underfloor heating pipe
5. Couplings,Cu15
6
7
Primary flow and
return
Connection
2
3
1
TMix® XS with immersion heater
The following components are for the TMix® XS with a 350W immersion heater:
6. Immersion heater, 350 W/230 V
Primary circulation
pump
7. Safety valve, 4 bar
2(4)
Switching from left to right connection
The TMix® XS is delivered with the couplings on the right as
standard. To move the couplings to the left, the mixing unit
is disconnected from the brackets and turned.
If an immersion heater is installed, the safety valve must be
turned so that it points outwards.
Thermotech underfloor heating system
Installation guide Thermotech TMix® XS mixing unit
Information about control alternatives
To control the mixing unit when connecting to an external heat source, the TMix® XS is equipped with one of the following
control units:
TMix® XS Standard
TMix® XS EC
TMix® XS ICR
Control
Included
components
Thermostatic head with air sensor 6–28°C (51904)
MATERIAL
NAME
DRAWN BY
APPV'D BY
MATERIAL
WEIGHT
DATE
DATE
Actuator (67034)
Adapter (67028)
Wired room thermostat (67210)
Wired control unit with transformer (67412)
2013-09-13
1 of 1
SCALE
1:3
PROJECT
+46620-683330
TITLE
DWG NO.
A3
REVISION
Spårvägen 8
901 31 Umeå
Sweden
SHEET
REVISION
Spårvägen 8
901 31 Umeå
Sweden
2013-09-13
WEIGHT
NAME
DRAWN BY
•
•
•
•
SHEET
1 of 1
SCALE
1:3
PROJECT
+46620-683330
TITLE
DWG NO.
A3
APPV'D BY
Product ID 67441-1 includes the following:
•
Actuator (67033)
•
Adapter (67028)
•
Wireless control unit (67441-0)
•
Wireless room thermostat
(67240)*
*Can be changed for wireless display
thermostat (67280).
Heat source
regulation
Thermostatic head with a twoway valve regulates the room
temperature.
A wired room thermostat regulates
the room temperature via an actuator
on the two-way valve.
A wireless room thermostat regulates
the room temperature via an actuator
on the two-way valve.
Electric boiler
regulation
The immersion heater has an
integrated thermostat that constantly maintains the floor temperature.*
The immersion heater has an integrated thermostat that constantly maintains the floor temperature.*
The immersion heater has an integrated thermostat that constantly maintains the floor temperature.*
The thermostat does not control the
immersion heater.
The thermostat regulates the maximum room temperature.
The thermostatic head does not
control the immersion heater.
Electric boiler/
heat source
switching
Switching is performed manually.
Switching via switch on
control unit.
Heat source mode:
The thermostatic head/thermostat controls the room temperature.
Electric boiler mode:
The thermostatic head/thermostat is set to the minimum position and the
immersion heater's integrated thermostat constantly maintains the floor
temperature.*
Heat source mode:
A wireless room thermostat regulates
the room temperature. The immersion heater is turned off.
Immersion heater mode:
The immersion heater has an inteThe immersion heater is only activated if the water temperature falls be- grated thermostat that constantly
maintains the floor temperature.* The
low 25°C.
If there is a risk of this occurring during the winter months, the immersion thermostat regulates the maximum
room temperature.
heater's plug should be pulled out of the wall outlet.
No connection to heat source.
Immersion heater, 350 W
Noise
The purpose of the immersion heater is to maintain a comfortable floor temperature for surfaces up to 12 m2 (29 W/
m2). The TMix® XS with an immersion heater can also be
used for heating surfaces up to 7 m2 (50 W/m2).
Thermotech's mixing units are equipped with circulation
pumps of high quality. Despite this, the pumps are not completely quiet during operation.
* The TMix® XS with an immersion heater is intended for
clinker floors and maintains an average floor temperature
of 25 ± 1.5°C.
NB: The temperature above cannot be regulated. The specified temperatures apply to heating loops embedded in concrete with maximum c/c spacing of 200 mm.
The lowest possible noise level is attained by having a properly deaerated underfloor heating system and a correctly
dimensioned pump. Equipment with circulation pumps
should not be installed close to areas that are especially sensitive to noise, such as bedrooms.
3(4)
M
D
A
Thermotech underfloor heating system
Installation guide Thermotech TMix® XS mixing unit
Heat conducting medium
Thermostatic valve (3)
Drinking water should be used as the heat conducting medium and normally does not require treatment. If there is
risk for freezing, an anti-freeze agent must be added when
the system is filled.
The integrated mixing unit is equipped with a DN15 thermostat valve. A fully open valve has a capacity value of 1.1.
The valve can be used with thermostatic heads, with air sensors or electric actuators.
Follow the respective manufacturers' instructions for correct mixture of the anti-freeze agent in the heat conducting
medium. We recommend however, a mixture with no more
than 30% glycol. Higher percentages can damage the heating system's components.
Installation of actuator 67034 requires an adapter ring (product ID 67028).
It is important that all included system components are
oxygen-diffusion tight. Oxygen encroachment can lead to
corrosion in the heating system and deposits in the heat
conducting medium, damaging moving system components.
The circulation pump has seven selectable speeds that are
chosen using the knob above the pump housing. The choice
of speed depends on system-specific properties. We recommend speed 2 or 3 as a basic setting.
Circulation pump
Lowara EBV 15-1/65 SC
The TMix® XS can be installed on or in walls. The following
recommendations apply:
• Do not install the mixing unit directly adjoining bedrooms.
• The mixing unit must not have direct contact with the
concrete slab via metal constructions.
• Firmly secure the mixing unit. Ensure that the mixing
unit is installed on a stable structural construction so
that vibrations and problems with noise do not occur.
The mixing unit must be installed with the pump's motor
shaft horizontal.
Once the mixing unit and the underfloor heating loops are
installed, the system must be filled. Fill the mixing unit with
water from the heating system and start the mixing unit's
pump. Now deaerate using the manual air vent.
NB: Take care in shutting the air vent once the air has been
removed from the system.
Leakage test
Applicable rules and instructions are described in the documentation for pressure and leakage tests that accompany
the underfloor heating delivery. The documentation can
also be downloaded at www.thermotech.eu.
Dimensions
78
80
316
320
140
140
60
60
250
250
70
70
4(4)
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
ANGULAR:
FINISH:
DEBUR AND
BREAK SHARP
EDGES
DO NOT SCALE DRAWING
REVISION
A-01
We reserve the right to change products without prior notice. Please refer to www.thermotech.se for the latest versions of
products and installation instructions. Any prices shown exclude VAT unless otherwise stated. No liability is accepted for any
typographical errors.
Filling and deaeration
Installation
Download