AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4 Hypak Area Lights - HP3 and HP4 Hypak - a series of high performance building mounted luminaires providing maximum versatility. Innovative optical design, low profile fixtures, and practical mechanical layout make Hypak a complete lighting system easy to specify, install, and maintain. Hypak’s low profile design and soft light are ideal for area lighting applications where control and visual comfort are important. 1 The HP3 Series – a versatile complement to the larger HP4 luminaires. 2 These units, offering eight unique light distributions, may be wall or ceiling mounted. Low level uses include illumination of stairways, pedestrian areas, entrances, ramps, and driveways. At higher levels, the HP3 is used to illuminate industrial work spaces, aisles, and garages. The HP3 Series is a compact, low glare, high performance luminaire for HID lamps to 150 Watts. Any one of eight light distributions within a single housing are created by combining one of two lenses and a choice of three reflectors. Symmetrical and asymmetrical distributions are available. The reflector and lens design provide excellent cutoff glare control and photometric performance. The result is visual comfort and performance found with a lower number of fixtures. 3 SPECIFICATIONS - HP3 WALL MOUNT Compact, one-piece lens door made of tough molded Lexan® polycarbonate. Fresnel linear spread lens for uniform light distribution. Durable stainless steel fasteners are easily removed for fixture access. CEILING MOUNT Fresnel spread lens for uniform light distribution. Durable stainless steel fasteners are easily removed for fixture access. High-performance reflectors provide four different wall mount distributions. Extruded aluminum reflectors are Alzak® treated for long-term, uniform lighting. Long lasting silicon gaskets completely seal the fixture to protect against water and bugs. Quick disconnects included for easy reflector installation or removal. Pulse rated porcelain sockets for medium base (or E-27) HID lamps to 150 Watts. High power factor ballasts mounted to housing for maximum heat dissipation, long life, and reliable lamp starting. High-performance reflectors provide three different ceiling mount distributions. Hydroform aluminum reflectors are Alzak® treated for longterm, uniform lighting. Long lasting Silicon gaskets completely seal the fixture to protect against water and bugs. Pulse-rated porcelain sockets for medium base (or E-27) HID lamps to 150 Watts. 4 Shallow and compact, durable, heat-dissipating one-piece die cast aluminum housing. High power factor ballasts mounted to housing for maximum heat dissipation, long life, and reliable lamp starting. Quick disconnects included for easy reflector installation / removal. Durable, heat-dissipating one-piece die cast aluminum housing is shallow and compact. Optional direct conduit entry for easy, straight-through wiring. Easy surface or recessed installation. Integrally cast knockouts provided for rear 4-0 box entry or independent mounting. Housing will be pre-shipped with RDE & RSB mountings. Optional direct conduit entry for easy, straight-through wiring. Easy surface or recessed installation. Integrally cast knockouts provided for rear 4-0 box entry or independent mounting. U.L. LISTED FOR WET LOCATIONS C.S.A. LISTED APPLICATION GUIDELINES - HP3 WALL MOUNT HORIZONTAL ILLUMINANCE RECOMMENDATIONS IN FOOTCANDLES (FC) LEVEL 1 MEDIUM LIGHT LEVEL Public access area with some protection, unfenced. Moderate light required for visibility and security. Recommended light level - 0.5 FC MIN LEVEL 2 HIGH LIGHT LEVEL High public access area with no protection. Lighting required for good visibility and security. Recommended light level - 1 FC MIN LEVEL 3 VERY HIGH LIGHT LEVEL Where maximum light level is required for highest visibility and security and/or accenting for sales impact. Recommended light level - 5 FC MIN HFW: HIGH FORWARD WALL DISTRIBUTION IES FILE: ITL33160 100M HFW @ 10’ (0.5 FC MIN) 33’ 100M HFW @ 10’ (1 FC MIN) 100M HFW @ 10’ (5 FC MIN) 30’ 18’ LHW: LOW HORIZONTAL WALL DISTRIBUTION IES FILE: ITL33869 100M LHW @ 3’ (0.5 FC MIN) 32’ * * * 100M LHW @ 3’ (1 FC MIN) 100M LHW @ 3’ (5 FC MIN) 27’ HORIZONTAL FC LEVELS ARE BASED ON 0% WALL REFLECTANCE. PLEASE VISIT WWW.HYDREL.COM TO DOWNLOAD DETAILED PERFORMANCE DATA IN IES FORMAT. RECOMMENDED LIGHT LEVELS FOR USE AS APPLICATION GUIDELINES ONLY, ACTUAL APPLICATIONS MAY REQUIRE DIFFERENT LEVELS. 17’ 5 APPLICATION GUIDELINES - HP3 WALL MOUNT LFW: LOW FORWARD WALL DISTRIBUTION IES FILE: ITL33163 100M LFW @ 3’ (0.5 FC MIN) 20’ 100M LFW @ 3’ (1 FC MIN) 100M LFW @ 3’ (5 FC MIN) 12’ 17’ LLW: LOW LEFT WALL DISTRIBUTION LRW: LOW RIGHT WALL DISTRIBUTION IES FILE: ITL33870 100M LLW/LRW @ 2’ (0.5 FC MIN) * * * 6 100M LLW/LRW @ 2’ (1 FC MIN) 100M LLW/LRW @ 2’ (5 FC MIN) HORIZONTAL FC LEVELS ARE BASED ON 0% WALL REFLECTANCE. PLEASE VISIT WWW.HYDREL.COM TO DOWNLOAD DETAILED PERFORMANCE DATA IN IES FORMAT. RECOMMENDED LIGHT LEVELS FOR USE AS APPLICATION GUIDELINES ONLY, ACTUAL APPLICATIONS MAY REQUIRE DIFFERENT LEVELS. APPLICATION GUIDELINES - HP3 CEILING MOUNT HSC: HIGH SYMMETRICAL DISTRIBUTION IES FILE: ITL33168 100M HSC @ 10’ (0.5 FC MIN) 100M HSC @ 10’ (1 FC MIN) 100M HSC @ 10’ (5 FC MIN) 21’ 24’ 12’ HNC: HIGH NARROW DISTRIBUTION IES FILE: ITL33171 100M HNC @ 10’ (0.5 FC MIN) 22’ 100M HNC @ 10’ (1 FC MIN) 100M HNC @ 10’ (5 FC MIN) 18’ 9’ HAC: HIGH ASYMMETRICAL DISTRIBUTION IES FILE: ITL33172 100M HAC @ 10’ (0.5 FC MIN) 22’ * * 100M HAC @ 10’ (1 FC MIN) 100M HAC @ 10’ (5 FC MIN) 18’ PLEASE VISIT WWW.HYDREL.COM TO DOWNLOAD DETAILED PERFORMANCE DATA IN IES FORMAT. RECOMMENDED LIGHT LEVELS FOR USE AS APPLICATION GUIDELINES ONLY, ACTUAL APPLICATIONS MAY REQUIRE DIFFERENT LEVELS. 10’ 7 MOUNTINGS - HP3 SNB SNB - FRONT SNB - SIDE SNB - BACK Two (2) 1/4” mounting holes for wall anchor bolts (bolts by others) SURFACE Surface mounting over recessed junction box (by others). Knockout mounting holes provided. 12 3/8” 2 1/4” 7” 11 3/8” Recessed 4-0 box (by others) Cast knockouts for 4-0 box mounting SDE/SSB - FRONT SDE SURFACE, DIRECT ENTRY Applications for direct conduit entry. Two (2) 1/2” NPS openings standard. SSB 12 3/8” 9” 6 1/4” SDE/SSB - BACK Two (2) 1/4” mounting holes for wall fasteners (fasteners by others) 1” 2 1/4” SDE: Two (2) 1/2” NPS side direct conduit entries 11 3/8” 7” 12 7/8” SSB: Two (2) 3/4” NPS side direct conduit entries in splice box SURFACE WITH SPLICE BOX Cast aluminum splice box included. 3/4” NPS openings standard. 5 7/8” RDE RDE/RSB - FRONT RDE/RSB - SIDE 12 3/8” 8” Min. RECESSED, DIRECT ENTRY Applications for direct conduit connections. Two (2) 1/2” NPS openings standard. RSB SDE/SSB - SIDE RDE/RSB - BACK Housing is held to front form with #10-24 fasteners threaded into housing. (fasteners by others) RDE: Two (2) 1/2” NPS side direct conduit entries 11 3/8” 10 5/8” 12 7/8” RSB: Two (2) 3/4” NPS side direct conduit entries in splice box RECESSED WITH SPLICE BOX Cast aluminum splice box included. 3/4” NPS side or bottom openings available. 5 11/16” 6 3/16” 11 5/8” BMS - FRONT BMS BASE, SINGLE Base mounting over recessed junction box (by others). Mounting plate provided. 12 3/8” BMS - SIDE BMT - TANDEM 9“ 18” 6 1/4” 11 3/8” BMT BASE, TANDEM Twin base mounting over recessed junction box (by others). 8 Four (4) set screws secure fixture to supplied mounting 12 7/8” 5 5/8” Recessed 4-0 box (by others) 12 7/8” 5 5/8” MOUNTINGS - HP3 SPM - FRONT SPM PENDANT, SINGLE Top pendant mounting below recessed junction box (by others). Set screws secure fixture to supplied mounting. TPM Recessed 4-0 box (by others) Four (4) set screws secure fixture to supplied mounting PMS - FRONT PMT - TANDEM 9” 18” 6 1/4” 11 3/8” 14 3/4” 15 1/2” 3 3/8” 4 1/8” PFD/PFS - FRONT PLASTER FRAME FOR DIRECT PFD/PFS - SIDE PFD/PFS - BACK 5/8” ENTRY 12 3/8” Eight (8) 1/4” dia. holes for attaching to dry wall plaster frame PFD: Two 1/2” NPS side direct conduit entries 11 3/4” 11 3/8” PFS PFS: Cast knockouts for 4-0 box mounting (4-0 box by others) PLASTER FRAME WITH SPLICE BOX Recessed in dry walls or ceilings. Knockouts available for Junction box (by others). SURFACE (CEILING) Mountings are Standard in Ceiling mounted versions when ordering HSC, HNC and HAC distributions. 18” PMS - SIDE 12 3/8” PFD SNB SDE SSB 12 7/8” 6 1/4” 9” 12 3/8” PMT Applications for direct conduit connections. Recessed in dry walls or ceilings. Two (2) 1/2” NPS openings standard. 5 5/8” 11 3/8” PMS POLE, TANDEM Twin Pole mounting on 2 3/8” dia. x 4” long tenon (by others) slip fitter secures with supplied fastener bolts. TPM - TANDEM 5 5/8” 12 7/8” PENDANT, TANDEM Twin pendant mounting below recessed junction box (by others). Set screws secure fixture to supplied mounting. POLE, SINGLE Pole mounting on 2 3/8” dia. x 4” long tenon (by others) slip fitter secures with supplied fastener bolts. SPM - SIDE 12 3/4” Cast knockouts for 4-0 box mounting SNB/SDE/SSB - BOTTOM SNB - SIDE Recessed 4-0 Box (by others) 12 3/8” 6 1/4” 9” 11 3/8” SDE/SSB - SIDE Two 1/2” NPS side direct conduit entries 6 1/4” 9” 1 11/16” RSB: Two (2) 3/4” NPS side direct conduit entries in splice box 9 The HP4 Series – high performance building mounted luminaires provide maximum versatility. 10 Innovative optical design, low profile fixtures and practical mechanical layout make HP4 lighting systems easy to specify, install, and maintain. HP4 low profile design and soft light are ideal for area lighting application where control and visual comfort are important. Common applications include building security, pedestrian areas, industrial work areas, garage, and parking areas. This wall mounted luminaire provides uniform light for large areas with excellent glare control to minimize intrusion. The Hypak HP4 is a versatile high performance sharp vertical cutoff luminaire capable of meeting all the needs of high level area lighting. The unit can be surface-mounted, recessed, pole, post, pendant, and base mounted to allow for maximum versatility. To insure long maintenance-free service, Hydrel uses a single die cast aluminum housing and a vandal resistant polycarbonate projecting lens. All hardware is stainless steel. Silicone gaskets assure weather and bug tight seals. 11 SPECIFICATIONS - HP4 WALL MOUNT One piece Lexan® hinged lens door is impact and vandal resistant. Stainless steel hinges provide easy door removal for fixture access. Fresnel linear spread lens of U.V. stabilized clear polycarbonate lens. Long lasting silicone gaskets provide protection against water and bugs. Durable stainless steel fasteners are easily removed for fixture access. High performance reflector is adjustable through sharp cutoff range of 70° to 85°. Unique three piece extruded aluminum reflector construction. Alzak treated aluminum for long term optical performance. Internal aiming scale is used for easy, accurate cut-off adjustment. Pulse-rated porcelain lamp sockets accept HID lamps to 250 Watts. Housing is durable, heat dissipating one piece die-cast aluminum. Quick disconnects are included for easy removal or installation of the reflector assembly. Integral cast knockouts provided for rear 4-0 box entry or independent mounting. High power factor ballasts are mounted directly to the housing for maximum heat dissipation, long life and reliable lamp starting. Heavy-duty polyester powder coat finish for long-term fixture performance. Housing will be pre-shipped with RSB mounting. Door rod holds door in open position for easier lamp replacement and maintenance. Easy access, quarter turn fasteners quickly releases reflector assembly. Reflector assembly is counterbalanced to provide easy access to ballast wiring area for installation and maintenance. 12 U.L. LISTED FOR WET LOCATIONS C.S.A. LISTED APPLICATION GUIDELINES - HP4 WALL MOUNT HORIZONTAL ILLUMINANCE RECOMMENDATIONS IN FOOTCANDLES (FC) LEVEL 1 MEDIUM LIGHT LEVEL Public access area with some protection, unfenced. Moderate light required for visibility and security. Recommended light level - 0.5 FC MIN LEVEL 2 HIGH LIGHT LEVEL High public access area with no protection. Lighting required for good visibility and security. Recommended light level - 1 FC MIN LEVEL 3 VERY HIGH LIGHT LEVEL Where maximum light level is required for highest visibility and security and/or accenting for sales impact. Recommended light level - 5 FC MIN HP4 175M @ 70° REFLECTOR ANGLE IES FILE: ITL31755 51’ 44’ 24’ 44’ 24’ 45’ 24’ HP4 175M @ 76° REFLECTOR ANGLE IES FILE: ITL31756 51’ HP4 175M @ 85° REFLECTOR ANGLE IES FILE: ITL31757 53’ * * * HORIZONTAL FC LEVELS ARE BASED ON 0% WALL REFLECTANCE. PLEASE VISIT WWW.HYDREL.COM TO DOWNLOAD DETAILED PERFORMANCE DATA IN IES FORMAT. RECOMMENDED LIGHT LEVELS FOR USE AS APPLICATION GUIDELINES ONLY, ACTUAL APPLICATIONS MAY REQUIRE DIFFERENT LEVELS. 13 MOUNTINGS - HP4 SNB - FRONT SNB SURFACE Surface mounting over recessed junction box (by others). Knockout mounting holes provided. 16 3/8” SNB - SIDE SNB - BACK Four (4) 1/4” mounting holes for wall anchor bolts (bolts by others) 11 3/8” 6 7/8” 12” 3 5/8” 15 5/8” Recessed 4-0 box (by others) SSB - FRONT SSB SURFACE WITH SPLICE BOX For applications where conduit is run on surface. Cast aluminum splice box included. 3/4” NPS openings standard. 16 3/8” SSB - SIDE 11 3/8” 6 7/8” Cast knockouts for 4-0 box mountings SSB - BACK Four (4) 1/4” mounting holes for wall anchor bolts (bolts by others) 12” 3 5/8” 15 5/8” 17 7/16” 5 7/8” RSB - FRONT RSB RECESSED WITH SPLICE BOX (Concrete Installation) For applications where unit needs to be recessed in concrete. Cast aluminum splice box included. 3/4” NPS openings standard. Housing back box can be pre-installed. 16 3/8” Two (2) 3/4” NPS side conduit entries in splice box. RSB - SIDE RSB - BACK Housing is held to front form with #10-24 fasteners threaded into housing. (fasteners by others) 8 1/2” min. 15 5/8” 4 13/16” 17 7/16” 13 5/8” Two (2) 3/4” NPS side conduit entries in splice box. 14 MOUNTINGS - HP4 BMS BMS - FRONT BASE MOUNT, SINGLE Base mounting over recessed junction box (by others). Mounting plate provided. BMT BASE MOUNT, TANDEM Twin base mounting over recessed 4-0 box (by others). Mounting plate provided. 15 5/8” 17 5/8” 17 7/16” Recessed 4-0 box (by others) 5 15/16” SPM - FRONT 5 15/16” 5 1/2” SPM - SIDE TPM - TANDEM 5 1/2” 5 1/2” Four (4) set screws secure fixture to supplied mounting 17 5/8” 15 5/8” 6 7/8” 16 3/8” PMS - FRONT POLE, SINGLE Pole mounting on 2 3/8” dia. x 4” long tenon (by others). Slip fitter secured with supplied fastener bolts. POLE, TANDEM Twin pole mounting on 2 3/8” dia. x 4” long tenon (by others). Slip fitter secured with supplied fastener bolts. Recessed 4-0 box (by others) 5 1/2” Four (4) set screws secure fixture to supplied mounting 17 1/16” PMS PMT BMT - TANDEM 22 3/4” 6 7/8” PENDANT, SINGLE Top pendant mounting below recessed junction box (by others). Mounting plate provided. PENDANT, TANDEM Twin pendant mounting below recessed junction box (by others). Mounting plate provided. 11 3/8” 16 3/8” SPM TPM BMS - SIDE 11 3/8” 22 3/4” PMS - SIDE 11 3/8” 16 3/8” PMT - TANDEM 22 3/4” 6 7/8” 15 5/8” 19 3/4” 19” 3 3/8” 4 1/8” 15 ORDERING GUIDE - HP3 HP3 Wall Mounted EXAMPLE: HP3 150M 120 HFW SDE Model Lamps Voltage Distribution Mounting HP3 INCANDESCENT: 116I A21, med. base HID: 50S E17, med. base 70S E17, med. base 100S E17, med. base 1 150S E17, med. base 50M E17, med. base 70M E17, med. base 100M E17, med. base 150M1 E17, med. base 100H B17, med. base 120 208 220 240 277 347 120/277 TB TBV HFW LHW LFW LLW LRW HSC HNC HAC High Forward Wall Low Horizontal Wall Low Forward Wall Low Left Wall Low Right Wall High Symmetrical Ceiling High Narrow Ceiling High Asymmetrical Ceiling Notes: 1 Not available with RSB and RDE. 2 Includes two fixtures and one mounting. 3 SF is only available with 120, 277 or 347 Volt, HID only. 4 DF is only available with 208, 220 or 240 Volt, HID only. 5 NEMA twist-lock receptacle only. Photo control by others. WH 16 DNAT GR STG SND BMS Base mount, single BMT2 Base mount, tandem PFD Plaster frame, direct entry PFS Plaster frame, splice box PMS Pole, single PTM2 Pole, tandem RDE Recessed, direct entry RSB Recessed, splice box SDE Surface, direct entry SNB Surface, no box SPM Pendant, single SSB Surface, splice box TPM2 Pendant, tandem TVG SF LPI BL Options Lamp Finish 3 LPI SF Singe Fuse DF4 Double Fuse 1,5 PER Photo Control Receptable QRS Quartz Emergency Restrike BZ GN Lamp BL Black Included BZ Bronze DDB Dark Bronze DNA Natural Alum. GN Green GR Gray SND Sand STG Steel Gray TVG Terra Verde Green WH White CF Custom Finish DDB BL ORDERING GUIDE - HP4 EXAMPLE: HP4 Product HP4 250M 120 Lamp Type HID: 100S 150S 250S1 175M 200M1 250M1 250H1 ED23 ½ Mogul ED23 ½ Mogul ED28 Mogul ED28 Mogul ED28 Mogul ED28 Mogul ED28 Mogul Voltage 120 208 220 240 277 347 480 120/277 TB TBV SNB Optional Lenses2 FLG3 Flat Lens Tempered Glass FLP4 Flat Lens Polycarbonate Mounting BMS BMT5 PMS PTM5 RSB SNB SPM TPM5 Notes: 1 Not available with RSB mounting. 2 Will be used in place of standard lens. 3 175 Watt maximum, reflector is not adjustable with this lens. 4 150 Watt maximum, reflector is not adjustable with this lens. 5 Includes two fixtures and one mounting. 6 SF is only available with 120, 277 or 347 volts on HID only. 7 DF is only available with 208, 220 or 240 volts on HID only. 8 NEMA twist-lock receptacle only. Photo control by others. WH DNAT GR STG SSB SND SF Base Mount, Single Base Mount, Tandem Pole Mount, Single Pole Tandem, Mount Recessed with Splice Box Surface, No Box Single Pendant Mount Tandem Pendant Mount Surface with Splice Box TVG LPI Option SF6 Single Fuse Double Fuse DF7 PER1,8 Photo Cell Receptacle QRS Quartz Re-Strike BZ GN Lamp LPI Lamp Included DDB BL Finish BL Black BZ Bronze DDB Dark Bronze DNA Natural Alum. GN Green GR Gray SND Sand STG Steel Gray TVG Terra Verde Green WH White CF Custom Finish BL 17 Form No. 106.15 11/04 12881 Bradley Avenue, Sylmar, CA 91342 T 818.362.9465 F 818.362.6548 Email: custserv@hydrel.com www.hydrel.com ©2004 Acuity Brands, Inc. All rights reserved. “Hydrel” is a trademark of Acuity Brands, Inc.