A WORLD POWER IN CABLE SUPPLY THE CABLE A N D AC C E S S O RY C ATA LO G U E 2 0 1 1 CLEVELAND CABLE LOCATIONS 2 CLEVELAND CABLE LOCATIONS 3 We are fortunate to have a very experienced and dedicated team of people who are able to assist and advise. Additionally our policy of continuing investment in the best available technology, warehousing, handling and measuring equipment and delivery vehicles enables us to guarantee all our customers an extremely high quality service. Enquiries are welcome from customers worldwide. Our export service is efficient and reliable with the ability to ship by air or sea freight to any destination. Please feel free to contact the distribution centre of your choice for an immediate, professional and trouble free service. Middlesbrough 01642 241133 Bristol 01179 382222 Glasgow 0141 6465000 Milton Keynes 01908 221414 London 0208 3114141 Newcastle 0191 2633363 Warrington 01925 655383 CLEVELAND CABLE COMPANY As is illustrated within our catalogue, we stock a comprehensive range of cables for every conceivable application. All types shown are considered as standard items to our range and are always available for immediate delivery. Our stocks are extremely large and unrivalled in the industry. CLEVELAND CABLE COMPANY 4 CLEVELAND CABLE COMPANY Cleveland Cable Company, established in 1978, is undoubtedly the foremost distributor of electrical cables in Great Britain and possibly Europe. The Head Office and principal stocking location is located at Middlesbrough in the North East of England. This site covers an area of twelve acres and includes over 160,000 square feet of warehousing. Additionally there are regional depots at Bristol, Glasgow, London, Milton Keynes, Newcastle and Warrington. Each location holds comprehensive stocks and is equipped with the most modern handling and measuring equipment. Deliveries are made by our own fleet of purpose-designed vehicles, all of which are fitted with hydraulic lifting equipment for safe offloading onsite and also efficient collection of empty drums. MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD LAND ACQUIRED FOR FUTURE DEVELOPMENT MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD 8 GLAND SELECTION GUIDELINES There are many factors to be considered when selecting cable glands for industrial installations. Neglecting to give due attention to these factors could cause unnecessary difficulties at a crucial point in time where most inconvenience and expense can result. It is most desirable to avoid discovering that, once all other equipment is on site or installed, the glands have not been ordered or are the wrong size or type. Good practice would be to allocate some planning and preparation time to cable gland selection. This will help avoid the possible disruption which could result at a critical point of the installation process. In the event of a project schedule of cables being available Cleveland Cable Company are happy to offer a gland selection and sizing service. Please contact any of our depots for further information or assistance. Here is a summary of some aspects to carefully consider when selecting cable glands. • Identify the type of cable to be used. • Check the construction, size and material properties of the cable. • Check the type and material of the cable armour (*) • Check the short circuit fault current rating of the cable armour (**) • Check the actual diameter of the inner bedding (where present) against this catalogue. • Check the actual diameter of the lead covering (where present) against this catalogue. • Check the actual size of the overall cable diameter against this catalogue. • Check the size and type or armour or braid (where present) against this catalogue. • Check any special environmental requirements in relation to corrosion protection. • Check the material of the mating electrical enclosures to eliminate dis-similar metals. • Consider whether any protective plating is required to be applied to the cable gland. • Check the type and size of the cable entry hole in the mating electrical equipment. • Check the ingress protection rating of the electrical equipment or site standard. • Check whether a single or double seal cable gland is required. • Check whether an entry thread seal is required for IP66 (or IP67/IP68) conditions. • Check whether fixing accessories such as locknuts and serrated washers are required. • Check whether earth tags are required. (**) • Check whether shrouds are required. • Select a corresponding cable gland type from this catalogue. • For installations in Hazardous Areas, special considerations should be taken into account to ensure compliance with national or international codes of practice. • Check whether a thread conversion adaptor or reducer is required to make the installation. • Select corresponding adaptors or reducers from this catalogue. • Check whether any stopper plugs are required to close unused cable entries. • Select corresponding stopper plugs from this catalogue. Note (*): If the cable armour is of a non standard material, i.e. Aluminium Wire Armour, it may be necessary to consider an alternative cable gland material, e.g. Aluminium. Note (**): For certain medium voltage and high voltage cables where the fault current carrying capacity of the cable armour is greater that that of the standard earth tag it may be necessary to consider a cable gland utilising the a heavy Cast Integral Earth Lug (CIEL) option which can be identified in the body of this catalogue. 9 6491X (HO7V-R) PVC insulated wiring, 1.5mm2 – 630mm2 ............................................................14 Bare copper strand, soft drawn to BS6360/81, 6mm2 – 400mm2 ................................................14 6181Y PVC insulated, PVC sheathed surface wiring, 1.0mm2 – 120mm2..................................15 624*Y PVC insulated, PVC sheathed surface wiring, 1mm2 – 16mm2 ........................................15 BS5467 Mains & control, XLPE, PVC SWA, PVC, 1.5mm2 – 16mm2 including multicores..........................................................................................................................................16 BS5467 Mains, XLPE, PVC, SWA, PVC, copper conductors, 25mm2 – 400mm2 ........................17 BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 4mm2 – 16mm2 ..........................18 BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 25mm2 – 400mm2 ......................19 BS5467 Mains, XLPE, PVC, SWA, PVC, aluminium conductors, 25mm2 – 300mm2 ................20 BS7889 Mains, single core, XLPE, PVC, non-armoured, 50mm2 –1000mm2 ............................21 BS5467 Mains, single core, XLPE, PVC, aluminium wire armoured, PVC, 50mm2 – 1000mm2 ..........................................................................................................................................22 Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% Conductivity in armour, 10mm2 – 300mm2 ............................................................................................................................23 EEMUA 133 Multicore, XLPE, lead sheathed, PVC, SWA, PVC, Control cable for petro-chemical industries, 1.5mm2 – 4mm2 ........................................................................................24 EEMUA 133 Mains, XLPE, lead sheathed, PVC,SWA, PVC, for petro-chemical industries, 1.5mm2 – 16mm2 ........................................................................................................................25 EEMUA 133 Mains, XLPE, lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 25mm2 – 300mm2 ......................................................................................................................26 Cathodic Protection Cables. XLPE, PVC, and XLPE, PVC, SWA, PVC, 6mm2 – 185mm2 ..........27 Concentric, split & straight, single phase service cable, 4mm2 – 35mm2 ................................28 SECTION 2 3300V Mains Cable BS5467 Mains, single core XLPE, PVC, aluminium wire armoured, PVC, 3300V, 120mm2 – 630mm2 ..........................................................................................................................................30 BS5467 Mains three core, XLPE, PVC, SWA, PVC, 3300V, 16mm2 – 400mm2 ............................31 Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% conductivity in armour, 3300V, 16mm2 – 300mm2 ..............................................................................................................................32 EEMUA 133 Mains, XLPE, Lead sheathed, PVC, SWA, PVC, for petro-chemical industries, 3300V, 25mm2 – 300mm2 ........................................................................................................33 SECTION 3 LSZH Fixed Wiring & Mains Cables 6491B (H07Z-R) LSZH insulated wiring, 1.5mm2 – 630mm2 ..........................................................36 6181B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm2 – 35mm2 ..............................37 624*B XLPE insulated, LSZH sheathed surface wiring 1.5mm2 – 16mm2 ..................................37 BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm2 – 16mm2 including multicores .........................................................................................................................................38 BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm2 – 400mm2 ............................................................39 BS6724 Mains, single core, XLPE, LSZH, 50mm2 – 1000mm2 ..........................................................40 CONTENTS SECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables CONTENTS 10 BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH, 50mm2 – 1000mm2 ..........................................................................................................................................41 BS8436 Protected fixed wiring cable, 1mm2 – 10mm2 ......................................................................42 SECTION 4 Medium Voltage 11000V & above BS6622 Mains, single core, XLPE, CTS, PVC, aluminium wire armoured, PVC, 11000V, 50mm2 – 630mm .............................................................................................................................44 BS6622 Mains, three core, XLPE, CTS, PVC, SWA, PVC, 11000V, 25mm2 – 400mm2 ..............44 BS6622 Mains, three core, aluminium conductor XLPE, CTS, PVC, SWA, PVC, 11000V, 95mm2 – 300mm2 ..........................................................................................................................45 Triplex, BS7870, aluminium conductor XLPE, CTS,MDPE, 11000V, utility cable, 70mm2 – 300mm2 ..............................................................................................................................................46 Paper insulated, BS6480 Mains, three core, SWA, PVC, 11000V, 25mm2 – 400mm2 ............47 BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH, 11000V, 50mm2 – 630mm2 ............................................................................................................................48 BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000V, 35mm2 – 400mm2 ..............................................................................................................................................48 BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 22000V and 33000v, 95mm2 – 185mm2 ............................................................................................................................................49 SECTION 5 High voltage 33000v service and windfarm cables BS7870 Mains, single core, aluminium conductors , XLPE, CWS, MDPE, 33000v 70mm2 – 630mm2 ..............................................................................................................................................52 BS7870 Mains, single core, copper conductors , XLPE, CWS, MDPE, 33000v 70mm2 – 630mm2 ............................................................................................................................53 SECTION 6 Fire Protection, Alarm & Security Cables Mineral Insulated................................................................................................................................................56 BS5839/BS7629 Fire performance alarm and security cable, 1mm2 – 4mm2 ......................................................................................................................................................57 BS5839/BS7629 Enhanced fire performance alarm and security cable 1.5mm2 – 4mm2 ....................................................................................................................58 BS6387 Fire performance single core cable, 1.5mm2 – 16mm2 ....................................................59 BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant,1.5mm2 – 16mm2, including multicores ......................................................................60 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, 25mm2 – 400mm2 ..............................................................................................................................................61 BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant, enhanced, 1.5mm2 – 16mm2, including multicores. ..........................................................................62 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, enhanced, 25mm2 – 400mm2 .............................................................................................................................................63 11 PVC and LSZH flexible cables 218*Y (H03VV-F) PVC, PVC, 0.5mm2 – 0.75mm2....................................................................................66 318*Y (H05VV-F) PVC, PVC, 0.5mm2 – 2.5mm2 ......................................................................................66 309*Y Heat resisting PVC, PVC, 0.5mm2 – 2.5mm2 ..............................................................................67 Arctic grade low temperature flex, 1.5mm2 – 6mm2 ..........................................................................67 318*B (H05ZIZI-F) LSZH, LSZH, 0.75mm2 – 2.5mm2 ............................................................................68 YY Control cable, 0.75mm2 – 1.5mm2 ........................................................................................................69 YY Control cable, 2.5mm2 – 50mm2............................................................................................................70 SY Control cable, 0.75mm2 – 2.5mm2 ........................................................................................................71 SY Control cable, 4.0mm2 – 95mm2 ............................................................................................................72 CY Control cable, 0.5mm2 – 16mm2 ..........................................................................................................73 YY Control cable, LSZH, 0.75mm2 – 25mm2 ............................................................................................74 CY Control cable, LSZH, 0.75mm2 – 1.5mm2 ..........................................................................................74 Tri-rated and Bi-rated BS6231, switchgear and control panel wire, 0.5mm2 – 400mm2 ............................................................................................................................................75 6381Y PVC, PVC, 6mm2 – 400mm2..............................................................................................................76 2491B/6701B (H05Z-K), flexible conductor, LSZH insulated wiring, 1.5mm2 – 240mm2 ............................................................................................................................................76 Solar Energy Cables 1.5mm2 – 35mm2......................................................................................................77 Rubber flexible cables BS6500 EPR insulated, CSP sheathed, flexible power & control, 0.75 – 2.5mm2 ..................78 BS7919 EPR insulated, CSP sheathed, flexible mains 4mm2 – 16mm2 ......................................79 BS7919 EPR insulated, CSP sheathed, flexible mains, 25mm2 – 630mm2 ................................80 HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm2 – 50mm2 ..............................81 HO7RN-F EPR insulated, PCP sheathed, flexible mains, 70mm2 – 630mm2 ............................82 380*P EPR insulated, copper braided screen, PCP sheathed, flexible mains, 1mm2 – 16mm2 ..................................................................................................................................................83 BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm2 – 2.5mm2 ............83 Coil lead BS6195 EPR, CSP, 0.5mm2 – 400mm2 .....................................................................................84 Welding cable, O361TQ EPR, CSP, 16mm2 – 185mm2 ........................................................................85 Flatform and silicon cables Flatform cable, PVC, PVC, 1.5mm2 – 95mm2 ..........................................................................................86 Flatform cable, EPR, PCP, 1.5mm2 – 70mm2 ............................................................................................86 Silicon insulated, silicon sheathed, flexible cable, 0.75mm2 – 2.5mm2 ......................................87 SECTION 8 Instrumentation, Control & Communication Cables BS5308 Control and instrumentation cable, non-armoured with collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2.........................................................................................................90 BS5308 Control and instrumentation cable, non-armoured with individual and collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2 ....................................................................91 BS5308 Control and instrumentation cable, armoured with collective screen, 0.5mm2 – 2.5mm2, part 1 and part 2 ........................................................................................................92 BS5308 Control and instrumentation cable, armoured with individual and collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2 ........................................................................................93 CONTENTS SECTION 7 Flexible Cables, PVC and Rubber CONTENTS 12 BS5308 Control and instrumentation cable, lead sheathed, armoured with collective screen, 0.75mm2 – 1.5mm2, part 1 and part 2..................................................................94 BS5308 Control and instrumentation cable, lead sheathed, armoured with individual and collective screen, 0.75mm2 – 1.5mm2, part 1 and part 2 ..................................95 BS5308 part 1 core identification................................................................................................................96 BS5308 part 2 core identification................................................................................................................97 British Steel specification CES20 type 134, 0.75mm2 ........................................................................98 British Steel specification CES20 type 143, 0.75mm2 ........................................................................99 CW1308 telephone cable ............................................................................................................................100 Telephone cable to ENATS 09-6 standard..........................................................................101/102/103 Utility Industry PVC Control Cables, ENATS 09-6 2.5mm2 ..............................................................103 ENATS 09-6 section 3.6 core identification ..........................................................................................104 ENATS 09-6 section 4.5 core identification ..........................................................................................104 Petroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS3573 ................105 Defence standard screened cable type 61-12 ....................................................................................106 Defence standard 61-12 parts 4 & 5 core identification ...............................................................107 Thermocouple extension and compensating cable, 0.75mm2 ....................................................108 Thermocouple core identification ............................................................................................................109 Traffic signal cable, loop feeder cable and loop detector cable ........................................110/111 SECTION 9 Data Cables Belden equivalents ..........................................................................................................................................114 Coaxial cables ....................................................................................................................................................114 Cat 5 data cables ..............................................................................................................................................114 Cat 6 data cables ..............................................................................................................................................114 SECTION 10 Railway Cables Signalling cable types A1, A2, A3, B1 and B2, 0.75mm2 – 95mm2 ............................................116 Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm2 – 35mm2 ..............117 Train protection warning system cable..................................................................................................118 Point heater cable ............................................................................................................................................118 Axle counting cable ..............................................................................................................................119/120 Datalink cable ....................................................................................................................................................119 Copper trackside cable ..................................................................................................................................121 Power cables, 16mm2 – 95mm2 ................................................................................................................122 Trackfeeder cables, 150mm2 – 1000mm2 ..............................................................................................122 SECTION 11 Marine and Offshore Cables EPR insulated, non-armoured shipwiring cable, 1.5mm2 –6mm2 ..............................................124 EPR insulated, non-armoured shipwiring cable, 10mm2 – 630mm2 ........................................125 EPR insulated, braided armoured shipwiring cable, 1.5mm2 – 4mm2 ......................................126 EPR insulated, braided armoured shipwiring cable, 6mm2 – 300mm2 ....................................127 EPR insulated, single core braided shipwiring cable, 6mm2 – 630mm2 ..................................128 SECTION 12 Installation Accessories ......................................................................129 13 FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES PVC 14 6491X (HO7V-R) PVC Stranded plain annealed compacted circular copper conductor, PVC outer sheath. Ref 6491X. Harmonised code HO7V-R. 450/750 volts grade to BS6004. Flame propagation to BS EN 50265. CCC CODE 6491X1/5 6491X2/5 6491X4 6491X6 6491X10 6491X16 6491X25 6491X35 6491X50 6491X70 6491X95 6491X120 6491X150 6491X185 6491X240 6491X300 6491X400 6491X500 6491X630 PVC INSULATED WIRING CABLE 6491X (1.5MM2 TO 630MM2) AND BARE COPPER STRAND (6MM2 TO 400MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 WEIGHT KG/KM 7/0.53 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.50 21 35 50 71 120 180 280 380 510 720 990 1200 1500 1900 2500 3000 3950 4950 6250 Temperature limits: -15 to +70°C. •Bending radius: OVERALL DIAMETER (MM) 3.00 3.65 4.20 4.75 6.15 7.10 8.90 9.95 11.70 13.35 15.60 17.20 19.10 21.30 24.30 27.05 30.35 32.80 36.50 BRASS A2 NYLON A2 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20 20 25 25 25 32 32 40 40 50S 50S 16 16 16 16 16 16 20 20 20 25 25 25 32 32 32 40 40 50 50 4mm2-630mm2 - Brown, Black, Grey, Blue, Green/Yellow. up to 10mm2 - 3 x overall diameter. above 25mm2 - 6 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. Standard colours available: 1.5mm2 & 2.5mm2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, Violet, Pink. BARE COPPER STRAND Stranded plain annealed compacted circular copper conductor, non insulated and non sheathed. 450 volts grade, soft drawn to BS6360/81. CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM CB006 CB010 CB016 CB025 CB035 CB050 CB070 CB095 CB120 CB150 CB185 CB240 CB300 CB400 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 58 96 154 240 336 480 672 912 1152 1440 1776 2304 2800 3750 OVERALL DIAMETER (MM) 3.0 4.2 5.1 5.9 7.8 8.8 9.8 12.5 12.8 14.4 16.1 19.8 20.6 26.4 Temperature limits: - 15 to + 70°C *Bending radius: Up to 10mm - 3 x overall diameter. Above 25mm - 6 x overall diameter. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 15 Plain annealed stranded circular copper conductor, single core, PVC insulated, PVC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004. Brown/Grey or Blue/Grey. Flame propagation to BS EN 50265. CCC CODE CONDUCTOR STRANDING SIZE (MM2) (MM) 6181Y1 6181Y1/5 6181Y2/5 6181Y4 6181Y6 6181Y10 6181Y16 6181Y25 6181Y35 6181Y50 6181Y70 6181Y95 6181Y120 PVC INSULATED PVC SHEATHED SURFACE WIRING CABLE TYPE 6181Y (1MM2 TO 120MM2) PVC INSULATED PVC SHEATHED WIRING CABLE TYPE 624*Y (1MM2 TO 16MM2) 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 NO. OF CORES 1/1.13 1/1.38 1/1.78 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19.2.52 37/2.03 1 1 1 1 1 1 1 1 1 1 1 1 1 WEIGHT OVERALL KG/KM DIAMETER (MM) 28 4.5 36 5.1 51 6.0 75 6.8 98 7.4 150 8.8 220 10.5 340 12.5 440 13.5 540 14.38 750 15.3 1010 17.7 1250 19.3 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 25 25 25 32 SINGLE CLEAT 0.5 0.5 0.6 0.6 0.7 0.7 0.8 Temperature limits: -15 to +70°C. •Bending radius: up to 10mm2 - 3 x overall diameter. over 10mm2 - 4 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. SURFACE WIRING CABLES PVC 624*Y Plain annealed copper conductor, PVC insulated one, two or three cores laid flat with an uninsulated circuit protective conductor and PVC sheathed. Grey. Ref 6241/2/3Y 300/500 V to BS6004. Flame propagation to BS EN 50265. CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) NO. OF CORES 6241Y1BR 6241Y1/5BR 6242Y1 6242Y1/5 6242Y1/5BRBR 6242Y2/5 6242Y4 6242Y6 6242Y10 6242Y16 6243Y1 6243Y1/5 6243Y2/5 1.0 1.5 1.0 1.5 1.5 2.5 4.0 6.0 10.0 16.0 1.0 1.5 2.5 1/1.13 1/1.37 1/1.13 1/1.38 1/1.38 1/1.77 7/0.85 7/1.04 7/1.35 7.1.70 1/1.13 1/1.37 1/1.77 1 1 2 2 2 2 2 2 2 2 3 3 3 WEIGHT KG/KM (MM) 49 51 69 85 85 120 175 240 390 560 92 115 170 OVERALL DIAMETER (MM) 4.15 X 5.40 4.65 X 5.80 4.10 X 8.65 4.55 X 8.80 4.55 X 8.80 5.40 X 10.50 6.10 X 12.00 6.90 X 13.80 8.40 X 18.50 9.70 X 20.60 4.60 X 10.20 4.75 X 11.45 5.45 X 13.40 Temperature limits: -15 to +70°C. *Bending radius: Fixed 3 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC SURFACE WIRING CABLES PVC 6181Y FIXED WIRING AND MAINS CABLES PVC 16 MAINS AND CONTROL CABLES PVC Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332. CCC CODE XLPE2X1/5 XLPE3X1/5 XLPE4X1/5 XLPE5X1/5 XLPE7X1/5 XLPE8X1/5 XLPE10X1/5 XLPE12X1/5 XLPE19X1/5 XLPE27X1/5 XLPE37X1/5 XLPE48X1/5 XLPE2X2/5 XLPE3X2/5* XLPE4X2/5 XLPE5X2/5 XLPE7X2/5 XLPE10X2/5 XLPE12X2/5 XLPE19X2/5 XLPE27X2/5 XLPE37X2/5 XLPE48X2/5 XLPE2X4 XLPE3X4* XLPE4X4 XLPE5X4 XLPE7X4 XLPE12X4 XLPE19X4 XLPE27X4 XLPE2X6 XLPE3X6* XLPE4X6 XLPE5X6 XLPE7X6 XLPE2X10 XLPE3X10* XLPE4X10 XLPE5X10 XLPE7X10 XLPE2X16 XLPE3X16* XLPE4X16 XLPE5X16 XLPE7X16 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 10.0 10.0 16.0 16.0 16.0 16.0 16.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 7/1.70 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. XLPE INSULATED MAINS AND CONTROL CABLE (1.5MM2 TO 16MM2) Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - up to 6mm2 White with Black numbers. NO. OF CORES 2 3 4 5 7 8 10 12 19 27 37 48 2 3 4 5 7 10 12 19 27 37 48 2 3 4 5 7 12 19 27 2 3 4 5 7 2 3 4 5 7 2 3 4 5 7 WEIGHT OVERALL KG/KM DIAMETER (MM) 234 11.06 271 11.54 306 12.26 356 13.23 391 14.1 501 16.7 650 18 657 18.3 863 20.78 1310 25.1 1590 27.5 1900 30 312 12.4 343 12.99 392 13.86 463 14.92 509 15.96 850 20 861 21.11 1324 25.16 1760 30 2185 33 2800 36 373 13.38 421 14.05 496 15.04 573 16.35 741 18.21 1255 24.24 1690 27.61 2250 32 450 14.38 515 15.14 696 17.03 808 18.39 1100 21.9 590 16.18 781 17.76 927 19.09 1095 20.91 1500 25 893 19.06 1059 20.35 1269 21.95 1679 25.19 2150 28.1 GLAND SIZE (MM) 20/16 20/16 20/16 20S 20S 20 20 20 25 25 32 32 20S 20S 20S 20S 20 25 25 25 32 40 40 20S 20S 20 20 20 25 32 32 20S 20 20 20 25 20 20 25 25 25 25 25 25 25 32 SINGLE CLEAT 0.5 0.5 0.5 0.6 0.6 0.7 0.8 0.8 0.9 1.0 1.1 1.2 0.5 0.6 0.6 0.6 0.8 0.8 0.9 1.0 1.2 1.4 1.6 0.6 0.6 0.6 0.7 0.8 1.0 1.1 1.4 0.6 0.7 0.7 0.8 0.9 0.7 0.8 0.8 0.9 1.0 0.8 0.9 0.9 1.1 1.2 5 core - 10mm2 and 16mm2 - Brown, Black, Grey, Blue, Green/Yellow 1.5 & 2.5 - 2,3,4 core also available in white numbered cores to ESI 09-6 Should not be installed at temperatures below 0°C or above +60°C. * Additionally these cables are stocked with Brown, Blue and Green/Yellow core identification. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 17 Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332. CCC CODE 6942X25 6943X25 6944X25 6945X25 6942X35 6943X35 6944X35 6945X35 6942X50 6943X50 6944X50 6945X50 6942X70 6943X70 6944X70 6945X70 6942X95 6943X95 6944X95 6945X95 6942X120 6943X120 6944X120 6942X150 6943X150 6944X150 6942X185 6943X185 6944X185 6942X240 6943X240 6944X240 6942X300 6943X300 6944X300 6942X400 6943X400 6944X400 CONDUCTOR STRANDING SIZE (MM2) (MM) 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 400 400 7/2.14 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 61/2.85 NO. OF CORES 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 WEIGHT OVERALL KG/KM DIAMETER (MM) 1050 20 1500 23 1800 25 2200 29 1400 22 1800 26 2200 28 2800 33 1750 25 2250 28 2850 31 3850 38 2200 28 3000 32 4100 37 5100 43 3000 32 4150 37 5200 40 7700 52 3600 35 4950 40 6700 46 4250 37 6300 45 7900 49 5500 43 7650 49 9650 55 6900 48 9650 56 12400 62 8200 50 11550 59 14800 66 10100 56 14350 65 19300 75 GLAND SIZE (MM) 25 25 32 32 25 32 32 40 32 32 32 40 32 32 40 50S 40 40 50S 50 40 50S 50 40 50 50 50 50 63S 50 63S 63 50 50 75S 63S 75S 75 SINGLE CLEAT 0.8 1.0 1.0 1.2 0.9 1.1 1.2 1.4 1.0 1.2 1.4 1.6 1.2 1.4 1.6 1.8 1.4 1.6 1.8 TC9 1.4 1.8 2.0 1.6 1.8 2.0 1.8 2.0 TC9 2.0 TC9 TC10 2.0 TC10 TC11 TC9 TC11 TC12 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED MAINS CABLE (25MM2 TO 400MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC MAINS CABLES PVC FIXED WIRING AND MAINS CABLES MDPE SHEATHED MDPE SHEATHED 18 FIXED WIRING AND MAINS CABLES MDPE SHEATHED Stranded plain annealed copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts grade generally to BS5467. CCC CODE 6942PE4 6943PE4 6944PE4 6942PE6 6943PE6 6944PE6 6942PE10 6943PE10 6944PE10 6942PE16 6943PE16 6944PE16 6945PE16 CONDUCTOR SIZE (MM) STRANDING 4.0 7/0.86 4.0 7/0.86 4.0 7/0.86 6.0 7/1.06 6.0 7/1.06 6.0 7/1.06 10.0 7/1.36 10.0 7/1.36 10.0 7/1.36 16.0 7/1.74 16.0 7/1.74 16.0 7/1.74 16.0 7/1.74 Temperature limits: - 15 to + 90°C *Bending radius: NO. OF CORES 2 3 4 2 3 4 2 3 4 2 3 4 5 WEIGHT OVERALL GLAND (KG/KM) DIAMETER SIZE (MM) 344 13.4 20S 389 14.1 20S 462 15.0 20S 418 14.4 20S 480 15.1 20S 655 17.0 20 552 16.2 20 739 17.8 20 881 19.1 20 847 19.1 20 1006 20.4 20 1211 22.0 25 1606 25.2 25 SINGLE CLEAT 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.8 0.9 0.9 1.0 Should not be installed at temperatures below 0°C or above 40°C. 8 x Overall Diameter Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. FIXED WIRING AND MAINS CABLES MDPE (4MM2 TO 16MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 19 Stranded plain annealed copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts grade generally to BS5467. CCC CONDUCTOR CODE SIZE (MM) STRANDING 6942PE25 25 7/2.21 6943PE25 25 7/2.21 6944PE25 25 7/2.21 6945PE25 25 7/2.21 6942PE35 35 7/2.66 6943PE35 35 7/2.66 6944PE35 35 7/2.66 6945PE35 35 7/2.66 6942PE50 50 19/1.88 6943PE50 50 19/1.88 6944PE50 50 19/1.88 6945PE50 50 19/1.88 6942PE70 70 19/2.21 6943PE70 70 19/2.21 6944PE70 70 19/2.21 6945PE70 70 19/2.21 6942PE95 95 37/1.88 6943PE95 95 37/1.88 6944PE95 95 37/1.88 6945PE95 95 37/1.88 6942PE120 120 30/2.32 6943PE120 120 30/2.32 6944PE120 120 30/2.32 6942PE150 150 37/2.32 6943PE150 150 37/2.32 6944PE150 150 37/2.32 6942PE185 185 37/2.55 6943PE185 185 37/2.55 6944PE185 185 37/2.55 6942PE240 240 60/2.32 6943PE240 240 60/2.32 6944PE240 240 60/2.32 6942PE300 300 61/2.66 6943PE300 300 61/2.66 6944PE300 300 61/2.66 6943PE400 400 60/2.96 6944PE400 400 60/2.96 Temperature limits: - 15 to + 90°C *Bending radius: NO. OF CORES 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 WEIGHT OVERALL GLAND (KG/KM) DIAMETER SIZE (MM) 1162 22.2 25 1562 24.9 25 1895 26.8 32 2280 29.5 32 1606 25.5 25 1964 27.2 32 2393 29.5 32 2898 32.4 32 1654 25.9 25 2199 28.6 32 2763 32.1 32 3876 36.4 40 2174 29.2 32 2937 32.3 32 3967 37.4 40 5166 41.7 50S 2987 33.2 32 4036 37.0 40 5128 41.6 50S 6795 48.6 50 3561 36.4 40 4829 40.5 50S 6578 47.0 50 4258 39.4 40 6268 45.8 50S 7967 51.5 50 5423 44.3 50S 7390 49.9 50 9403 56.2 63S 6736 49.2 50 9238 55.1 63S 11898 62.4 63 7896 51.3 50 11136 60.3 63 14328 68.4 75S 13778 67.9 75S 18669 78.8 90 SINGLE CLEAT 0.9 1.0 1.1 1.2 1.1 1.1 1.2 1.4 1.1 1.2 1.4 1.6 1.2 1.4 1.6 1.8 1.4 1.6 1.8 2.0 1.6 1.6 2.0 1.6 2.0 TC9 1.8 2.0 TC9 2.0 TC9 TC10 TC9 TC10 TC11 TC11 TC14 Should not be installed at temperatures below 0°C or above 40°C. 8 x Overall Diameter Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. FIXED WIRING AND MAINS CABLES MDPE (25MM2 TO 400MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES MDPE SHEATHED FIXED WIRING AND MAINS CABLES MDPE SHEATHED FIXED WIRING AND MAINS CABLES PVC 20 MAINS CABLES WITH ALUMINIUM CONDUCTORS PVC Solid plain aluminium sectoral conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332. CCC CODE CONDUCTOR SIZE (MM2) NO. OF CORES WEIGHT KG/KM SAC4X25 SAC4X35 SAC4X50 SAC4X70 SAC4X95 SAC4X120 SAC4X150 SAC4X185 SAC4X240 SAC4X300 25 35 50 70 95 120 150 185 240 300 4 4 4 4 4 4 4 4 4 4 1235 1515 1686 2401 2905 3705 4550 5076 6104 7212 OVERALL DIAMETER (MM) 25.4 28.9 29.5 34.7 38.3 42.2 46.0 51.1 56.4 61.4 GLAND SIZE (MM) 25 32 32 40 40 50S 50 50 63S 63 SINGLE CLEAT 1.0 1.2 1.2 1.4 1.6 1.8 2.0 TC9 TC9 TC10 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED MAINS CABLE WITH ALUMINIUM CONDUCTORS (25MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 21 Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, PVC outer sheath Black. 600/1000 volts grade to BS7889/97. Flame propagation to BS EN 60332. CCC CODE CONDUCTOR STRANDING WEIGHT OVERALL SIZE (MM2) (MM) KG/KM DIAMETER (MM) 6181X50 50 19/1.78 520 13.5 6181X70 70 19/2.14 720 15.5 6181X95 95 19/2.52 985 17.5 6181X120 120 37/2.03 1215 19 6181X150 150 37/2.25 1515 21.5 6181X185 185 37/2.52 1865 23.5 6181X240 240 61/2.25 2415 26.5 6181X300 300 61/2.52 3005 29 6181X400 400 61/2.85 3810 32.5 6181X500 500 61/3.20 4890 37 6181X630 630 127/2.52 6355 42 6181X800 800 127/2.85 8075 46 6181X1000 1000 127/3.20 9860 53 BRASS A2 25 25 25 32 32 32 40 40 50S 50S 50 63S 63 NYLON SINGLE TREFOIL A2 CLEAT CLEAT 25 25 25 32 32 32 40 40 50 50 63 - 0.6 0.7 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.6 1.8 2.0 TC9 376AC04 376AC06 376AC09 376AC12 376AC15 376AC19 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown inner / Black outer. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED SINGLE CORE NON-ARMOURED MAINS CABLE (50MM2 TO 1000MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC SINGLE CORE NON-ARMOURED MAINS CABLES PVC FIXED WIRING AND MAINS CABLES PVC 22 FIXED WIRING AND MAINS CABLES Stranded plain annealed compacted circular copper conductors, XLPE insulated, PVC bedding, aluminium wire armoured, PVC outer sheath. Black. 600/100 volts grade to BS5467. Flame propagation to BS EN 60332. CCC CODE 6941AX50 6941AX70 6941AX95 6941AX120 6941AX150 6941AX185 6941AX240 6941AX300 6941AX400 6941AX500 6941AX630 6941AX800 6941AX1000 CONDUCTOR NO. OF WEIGHT OVERALL GLAND GLAND SINGLE SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE CLEAT ALI(MM) BRASS A2 (MM) 50.0 19/1.78 1 638 17.70 20 25 0.7 70.0 19/2.14 1 891 19.60 25 32 0.8 95.0 19/2.52 1 1166 21.50 25 32 0.9 120.0 37/2.03 1 1412 23.10 25 32 1.0 150.0 37/2.25 1 1800 26.00 32 40 1.1 185.0 37/2.52 1 2200 28.00 32 40 1.2 240.0 61/2.25 1 2800 32.00 40 50S 1.4 300.0 61/2.52 1 3400 33.00 40 50S 1.4 400.0 61/2.85 1 4450 38.00 40 50 1.6 500.0 61/3.2 1 5550 43.00 50S 63S 1.8 630.0 127/2.52 1 7100 47.00 50 63S 2.0 800.0 127/2.85 1 9200 55.00 63S 75S TC9 1000.0 127/3.2 1 11270 58.80 63S 75S TC10 TREFOIL CLEAT 376AC04 376AC06 376AC06 376AC10 376AC13 376AC15 376AC20 376AC22 Temperature limits: - 15 to + 90°C *Bending radius: 6 x Overall Diameter Core identification: Brown inner - Black outer Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED SINGLE CORE ARMOURED MAINS CABLE (50MM2 TO 1000MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 23 Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000 volts grade generally to BS5467 and BC295. Flame propagation to BS EN 60332. CCC CODE NCB3X10/1 NCB4X10/1 NCB3X16/1 NCB4X16/1 NCB3X25 NCB4X25 NCB3X35 NCB4X35 NCB3X50 NCB4X50 NCB3X70 NCB4X70 NCB3X95 NCB4X95 NCB3X120 NCB4X120 NCB3X150 NCB4X150 NCB3X185 NCB4X185 NCB3X240 NCB4X240 NCB3X300 NCB4X300 CONDUCTOR STRANDING SIZE (MM2) (MM) 10 10 16 16 25 25 35 35 50 50 70 70 95 95 120 120 150 150 185 185 240 240 300 300 7/1.04 7/1.04 7/1.70 7/1.70 7/2.14 7/2.14 7/2.52 7/2.52 19/1.78 19/1.78 19/2.14 19/2.14 19/2.52 19/2.52 37/2.03 37/2.03 37/2.25 37/2.25 37/2.52 37/2.52 61/2.25 61/2.25 61/2.52 61/2.52 NO. OF CORES 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 WEIGHT OVERALL KG/KM DIAMETER (MM) 896 18.9 1038 20.3 1205 23.1 1675 26.3 1550 26.9 1880 29.1 1940 29.6 2350 32.1 2360 28.4 2950 31.3 3120 32.0 4230 36.8 4310 36.7 5390 40.6 5160 40.0 6980 45.8 6610 45.1 8300 49.9 7920 49.3 10070 54.9 9930 54.5 12680 61.0 11970 59.5 15380 66.5 GLAND SIZE (MM) 20 20 25 25 25 32 32 32 32 32 32 40 40 50S 50S 50S 50S 50 50 63S 63S 63 63 75S SINGLE CLEAT 0.8 0.8 1.0 1.1 1.1 1.2 1.2 1.4 1.2 1.4 1.4 1.6 1.6 1.6 1.6 2.0 1.8 2.0 2.0 TC9 TC9 TC10 TC10 TC11 Temperature limits: -15 to +70°C. *Bending radius: up to 16mm2 - 6 x overall diameter. over 16mm2 - 8 x overall diameter. Core identification: 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED MAINS CABLE WITH 60% CONDUCTIVITY IN ARMOUR. (MINES & QUARRIES & BRITISH COAL) (10MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC MAINS CABLES FOR MINES & QUARRIES PVC FIXED WIRING AND MAINS CABLES PVC 24 EEMUA133 CONTROL CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores white with black numbers. 600/1000 volts grade to BS5467 and EEMUA 133. Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC CODE EEMUA2X1/5ESI EEMUA3X1/5ESI EEMUA4X1/5ESI EEMUA5X1/5 EEMUA7X1/5 EEMUA12X1/5 EEMUA19X1/5 EEMUA27X1/5 EEMUA37X1/5 EEMUA2X2/5ESI EEMUA3X2/5ESI EEMUA4X2/5ESI EEMUA5X2/5 EEMUA7X2/5 EEMUA12X2/5 EEMUA19X2/5 EEMUA27X2/5 EEMUA37X2/5 EEMUA5X4 EEMUA7X4 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 NO. OF CORES 2 3 4 5 7 12 19 27 37 2 3 4 5 7 12 19 27 37 5 7 WEIGHT OVERALL KG/KM DIAMETER (MM) 690 15 750 15.5 810 16 895 16.8 1072 17.7 1387 22.3 1686 24.8 2418 30 2850 32.7 800 16 870 16.5 950 17.5 1038 18.4 1180 20 1750 24.5 2450 29 3100 33 3720 36 1014 20.6 1110 21.5 GLAND SIZE (MM) 20 20 20 20 20 25 25 32 32 20 20 20 20 20 25 32 32 40 20 25 SINGLE CLEAT 0.6 0.7 0.7 0.7 0.7 0.9 1.0 1.2 1.4 0.7 0.7 0.7 0.8 0.8 1.0 1.2 1.4 1.6 0.9 0.9 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED LEAD SHEATHED CONTROL CABLE FOR PETRO-CHEMICAL INDUSTRIES (1.5MM2 TO 4MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 25 Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC CODE EEMUA2X1/5 EEMUA3X1/5 EEMUA4X1/5 EEMUA2X2/5 EEMUA3X2/5 EEMUA4X2/5 EEMUA2X4 EEMUA3X4 EEMUA4X4 EEMUA2X6 EEMUA3X6 EEMUA4X6 EEMUA2X10 EEMUA3X10 EEMUA4X10 EEMUA2X16 EEMUA3X16 EEMUA4X16 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 2.5 2.5 2.5 4.0 4.0 4.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 NO. OF CORES 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 WEIGHT OVERALL KG/KM DIAMETER (MM) 690 15 750 15.5 810 16 800 16 870 16.5 950 17.5 920 17.5 1000 17.5 1110 19 1020 18 1150 19 1400 20.5 1250 20 1530 22 1720 23 1630 23 1880 24 2150 26 GLAND SIZE (MM) 20 20 20 20 20 20 20 20 25 20 25 25 25 25 25 25 25 32 SINGLE CLEAT 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.8 0.9 1.0 1.0 1.0 1.1 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES (1.5MM2 TO 16MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC EEMUA133 MAINS CABLES PVC FIXED WIRING AND MAINS CABLES PVC 26 EEMUA133 MAINS CABLES PVC Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC CODE EEMUA2X25 EEMUA3X25 EEMUA4X25 EEMUA2X35 EEMUA3X35 EEMUA4X35 EEMUA2X50 EEMUA3X50 EEMUA4X50 EEMUA2X70 EEMUA3X70 EEMUA4X70 EEMUA2X95 EEMUA3X95 EEMUA4X95 EEMUA2X120 EEMUA3X120 EEMUA4X120 EEMUA2X150 EEMUA3X150 EEMUA4X150 EEMUA2X185 EEMUA3X185 EEMUA4X185 EEMUA2X240 EEMUA3X240 EEMUA4X240 EEMUA2X300 EEMUA3X300 CONDUCTOR STRANDING SIZE (MM2) (MM) 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 7/2.14 7/2.14 7/2.14 19/1.53 19/1.53 19/1.53 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 NO. OF CORES 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 WEIGHT OVERALL KG/KM DIAMETER (MM) 2094 27.1 2740 30 3160 32 2868 31.9 3205 32 3840 34.5 2783 28.1 3655 33.5 4530 37 3566 31.1 4675 37.5 6175 43 4678 35.1 6180 42.5 7695 47 5641 38.5 7390 46 9730 53 6660 41.8 9300 52 11530 58.5 8457 47.1 10980 56.5 14160 65 10286 52.3 13815 63 17700 65.8 16519 64.1 21173 71.5 GLAND SIZE (MM) 32 32 32 32 32 40 32 40 40 32 40 50S 40 50S 50 50S 50 63S 50S 50 63S 50 63S 63 50 63 75S 63 75S SINGLE CLEAT 1.1 1.2 1.4 1.4 1.4 1.4 1.2 1.6 1.6 1.4 1.6 1.8 1.4 1.8 2.0 1.6 2.0 TC9 1.8 TC9 TC10 2.0 TC9 TC11 TC9 TC10 TC11 TC11 TC12 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: 2 core - Brown, Blue 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES (25MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 27 Plain annealed compacted circular copper conductor, XLPE insulated, PVC outer sheath, 600/1000 volts grade generally to BS5467 & IEC 60502. Colours Black/Black or Red/Red. CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM 6181X6 6181X10 6181X16 6181X25 6181X35 6181X50 6181X70 6181X95 6181X120 6181X150 6181X185 6 10 16 25 35 50 70 95 120 150 185 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 105 150 210 305 395 515 725 1230 1355 1695 2110 *Bending radius: GLAND SIZE (MM) 20/16 20/16 20S 20S 20 20 25 25 32 32 32 Should not be installed at temperatures below 0°C or above +60°C. 4 x overall diameter. XLPE INSULATED NONARMOURED AND ARMOURED SINGLE CORE CABLE FOR CATHODIC PROTECTION (6MM2 TO 185MM2) OVERALL DIAMETER (MM) 7.2 8.1 9.0 10.6 11.6 13.0 14.9 17.5 19.2 21.3 23.4 SINGLE CORE ARMOURED CATHODIC PROTECTION CABLES PVC Plain annealed compacted circular copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade generally to IEC 60502 & BS5467. CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM 6941X6 6941X10 6941X16 6941X25 6941X35 6941X50 6941X70 6941X95 6941X120 6941X150 6941X185 6 10 16 25 35 50 70 95 120 150 185 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 285 355 435 585 685 835 1080 1375 1685 2120 2505 *Bending radius: 4 x overall diameter. OVERALL DIAMETER (MM) 11.5 12.5 13.5 15.0 16.0 17.5 19.5 21.6 23.4 26.4 28.9 GLAND SIZE (MM) 20/16 20/16 20S 20S 20 20 20 25 25 25 32 Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC SINGLE CORE NON-ARMOURED CATHODIC PROTECTION CABLES PVC FIXED WIRING AND MAINS CABLES PVC 28 SPLIT CONCENTRIC CABLES PVC Plain annealed stranded copper phase conductor, XLPE insulated surrounded by a concentric layer of plain annealed solid copper neutral conductors. XLPE insulated and plain annealed solid strand bare copper earth conductors, PVC outer sheath. Black. 600/1000 volts grade to BS 7870. CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM 4 SPLITCON 6 SPLITCON 10 SPLITCON 16 SPLITCON 25 SPLITCON 35 SPLITCON 4 6 10 16 25 35 7/0.85 7/1.04 7/1.35 7/1.70 **7/2.14 7/2.52 206 281 394 583 843 1300 OVERALL DIAMETER (MM) 9.6 11.4 12.7 14.6 18.7 23.0 GLAND SIZE (MM) 20S 20 20 25 32 40 **Stranding of neutral is the same as phase conductor except 25 sq mm which has 11 x 1.70mm. Should not be installed at temperatures below 0°C or above +60°C. Conductor identification: Brown Live/Blue Neutral. Also available in Violet outer sheath in 6mm, 10mm, 16mm & 25mm. STRAIGHT CONCENTRIC CABLES PVC Plain annealed stranded copper phase conductor, PVC insulated surrounded by a concentric layer of plain annealed solid copper neutral/earth conductors in concentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 7870 & ESI 09-7. Combined neutral and earth (CNE). CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM 4 STRCON 6 STRCON 16 STRCON 25 STRCON 35 STRCON 4 6 16 25 35 7/0.85 7/1.04 7/1.70 7/2.14 7/2.25 180 230 440 600 850 OVERALL DIAMETER (MM) 9.0 10.0 12.0 15.0 16.0 GLAND SIZE (MM) 20S 20S 20 25 25 Temperature limits: -15 to +70°C. *Bending radius: 10 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED SINGLE PHASE SPLIT AND STRAIGHT CONCENTRIC SERVICE CABLE (4MM2 TO 35MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 29 FIXED WIRING AND MAINS CABLES PVC FIXED WIRING AND MAINS CABLES 3300V PVC FIXED WIRING AND MAINS CABLES PVC 30 SINGLE CORE ARMOURED MAINS CABLES 1900/3300V Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, Aluminium wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN 60332. CCC CODE 6941AX120/3 6941AX150/3 6941AX185/3 6941AX240/3 6941AX300/3 6941AX400/3 6941AX500/3 6941AX630/3 CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT (MM) (MM) 120 37/2.03 1 1490 23.2 25 1.2 150 37/2.25 1 1870 26.3 32 1.2 185 37/2.52 1 2290 28.7 32 1.4 376AC04 240 61/2.25 1 2880 31.4 40 1.4 376AC05 300 61/2.52 1 3520 34.1 40 1.8 376AC07 400 61/2.85 1 4520 38.9 50S 1.8 376AC10 500 61/3.20 1 5680 42.8 50S 1.8 376AC12 630 127/2.52 1 7120 47.3 50 2.0 376AC15 Temperature limits: -25 to +90°C. *Bending radius: 6 x overall diameter. Core identification: Brown inner/Black outer. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED SINGLE CORE ARMOURED MAINS CABLE 3300V (120MM2 TO 630MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 31 Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN 60332. CCC CODE XLPE3X16/3 XLPE3X25/3 XLPE3X35/3 XLPE3X50/3 XLPE3X70/3 XLPE3X95/3 XLPE3X120/3 XLPE3X150/3 XLPE3X185/3 XLPE3X240/3 XLPE3X300/3 XLPE3X400/3 CONDUCTOR STRANDING SIZE (MM2) (MM) 16 25 35 50 70 95 120 150 185 240 300 400 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 NO. OF CORES 3 3 3 3 3 3 3 3 3 3 3 3 WEIGHT OVERALL KG/KM DIAMETER (MM) 1600 29.5 2060 32.3 2330 35.0 3040 34.9 3800 38.0 4730 41.4 6070 45.6 7010 48.3 8270 51.6 10310 56.5 12300 60.7 14780 65.8 GLAND SIZE (MM) 32 32 40 40 40 50S 50S 50 50 63S 63 75S SINGLE CLEAT 1.2 1.4 1.4 1.4 1.6 1.8 1.8 2.0 TC9 TC9 TC10 TC11 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown, Black, Grey. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED MAINS CABLE 3300 VOLT (16MM2 TO 400MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC 3 CORE MAINS CABLES 1900/3300V PVC FIXED WIRING AND MAINS CABLES PVC 32 MAINS CABLES FOR MINES & QUARRIES 1900/3300V Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 1900/3300 volts grade generally to BS5467 and BC295. Flame propagation to BS EN 60332. CCC CODE NCB3X16/3 NCB3X25/3 NCB3X35/3 NCB3X50/3 NCB3X70/3 NCB3X95/3 NCB3X120/3 NCB3X150/3 NCB3X185/3 NCB3X240/3 NCB3X300/3 CONDUCTOR STRANDING SIZE (MM2) (MM) 16 25 35 50 70 95 120 150 185 240 300 7/1.70 19/1.35 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 NO. OF CORES 3 3 3 3 3 3 3 3 3 3 3 WEIGHT OVERALL KG/KM DIAMETER (MM) 1600 29.5 2060 32.3 2330 35.0 3040 34.9 3800 38.0 4730 41.4 6070 45.6 7110 48.3 8270 51.6 10310 56.5 12300 60.7 GLAND SIZE (MM) 32 32 40 40 40 50S 50S 50 50 63S 63 SINGLE CLEAT 1.2 1.4 1.4 1.4 1.6 1.8 1.8 2.0 TC9 TC9 TC10 Temperature limits: -15 to +70°C. *Bending radius: up to 16mm2 - 6 x overall diameter. over 16mm2 - 8 x overall diameter. Core identification: 3 core - Brown, Black, Grey Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED MAINS CABLE 3300V WITH 60% CONDUCTIVITY IN ARMOUR. (MINES & QUARRIES & BRITISH COAL) (16MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 33 Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-22 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC CODE EEMUA3X25/3 EEMUA3X35/3 EEMUA3X50/3 EEMUA3X70/3 EEMUA3X95/3 EEMUA3X120/3 EEMUA3X150/3 EEMUA3X185/3 EEMUA3X240/3 EEMUA3X300/3 CONDUCTOR STRANDING SIZE (MM2) (MM) 25 35 50 70 95 120 150 185 240 300 7/2.14 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 NO. OF CORES 3 3 3 3 3 3 3 3 3 3 WEIGHT OVERALL KG/KM DIAMETER (MM) 3400 32.5 3560 38.4 4520 38.1 5550 41.4 6770 45.0 8390 49.4 9630 52.3 11270 55.8 13720 60.9 16380 65.3 GLAND SIZE (MM) 32 40 40 50S 50S 50 50 63S 63 75S SINGLE CLEAT 1.4 1.6 1.6 1.8 2.0 2.0 TC9 TC9 TC10 TC11 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: Brown, Black, Grey. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED LEAD SHEATHED MAINS CABLE FOR PETRO-CHEMICAL INDUSTRIES 3300 VOLT (25MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PVC EEMUA133 MAINS CABLES 1900/3300V PVC 35 FIXED WIRING AND MAINS CABLES LSZH FIXED WIRING AND MAINS CABLES LSZH FIXED WIRING AND MAINS CABLES LSZH 36 6491B (HO7Z-R) LSZH Stranded plain annealed compacted circular copper conductor, low smoke and zero halogen (LSZH) outer sheath. 450/750 volts grade to BS7211. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and zero halogen (LSZH). CCC CODE 6491B1/5 6491B2/5 6491B4 6491B6 6491B10 6491B16 6491B25 6491B35 6491B50 6491B70 6491B95 6491B120 6491B150 6491B185 6491B240 6491B300 6491B400 6491B500 6491B630 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 WEIGHT KG/KM 7/0.53 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.50 22 33 49 69 116 175 273 367 510 715 990 1230 1510 1900 2490 3050 3842 4900 6334 OVERALL DIAMETER (MM) 3 3.65 4.2 4.75 6.15 7.1 8.9 9.95 11.7 13.35 15.6 17.2 19.1 21.3 24.36 27.05 30.35 32.8 36.5 BRASS A2 NYLON A2 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20 20 25 25 25 32 32 40 40 50S 50S 16 16 16 16 16 16 20 20 20 25 25 25 32 32 32 40 40 50 50 Temperature limits: -15 to +90°C. *Bending radius: up to 10mm2 - 3 x overall diameter above 25mm2 - 6 x overall diameter Standard colours available: 1.5mm2 & 2.5mm2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, Violet, Pink. 4mm2 - 630mm2 - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above +40°C. LOW SMOKE ZERO HALOGEN INSULATED WIRING CABLE 6491B (1.5MM2 TO 630MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 37 Plain annealed stranded circular copper conductor, single core, XLPE insulated, (LSZH) sheathed, Ref 6181B. 300/500 volts grade to BS7889. Brown/White or Grey/White. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and zero halogen (LSZH). CCC CODE CONDUCTOR STRANDING SIZE (MM2) (MM) 6181B1 6181B1/5 6181B2/5 6181B4 6181B6 6181B10 6181B16 6181B25 6181B35 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 NO. OF CORES 1/1.13 1/1.38 1/1.78 7/0.85 7/1.04 7/1.35 7/1.04 7/2.14 7/2.52 Temperature limits: -25 to +90°C. *Bending radius: XLPE INSULATED LSZH SHEATHED SURFACE WIRING CABLE TYPE 6181B (1MM2 TO 35MM2) XLPE INSULATED LSZH SHEATHED WIRING CABLE TYPE 624*B 2 (1MM TO 16MM2) 1 1 1 1 1 1 1 1 1 WEIGHT OVERALL KG/KM DIAMETER (MM) 28 4.5 34 5.1 49 6.0 75 6.8 99 7.4 155 8.8 225 10.5 340 12.5 440 13.5 GLAND REF (MM) 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 CLEAT SIZE 0.5 0.5 0.6 Should not be installed at temperatures below 0°C or above +40°C. up to 10mm2 - 3 x overall diameter over 10mm2 - 4 x overall diameter SURFACE WIRING CABLES LSZH 624*B Plain annealed compacted copper conductor, XLPE insulated, one, two or three cores laid flat with an uninsulated circuit protective conductor and (LSZH) sheathed. White. Ref 6241/2/3B 300/500V to BS7211 low smoke and zero halogen (LSZH). Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and zero halogen (LSZH). CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) NO.OF CORES 6241B1/5BR 6241B1/5BR 6242B1WH 6242B1/5WH 6242B1/5BRBR 6242B2/5WH 6242B4WH 6242B6WH 6242B10WH 6242B16WH 6243B1WH 6243B1/5WH 6243B2/5WH 1.5 1.5 1.0 1.5 1.5 2.5 4.0 6.0 10.0 16.0 1.0 1.5 2.5 1/1.37 1/1.37 1/1.13 1/1.37 1/1.37 1/1.77 7/0.85 7/1.04 7/1.35 7/1.70 1/1.13 1/1.37 1/1.77 1 1 2 2 2 2 2 2 2 2 3 3 3 Temperature limits: -25 to +90°C. *Bending radius: WEIGHT KG/KM (MM) 51 51 69 85 85 120 175 240 390 560 92 115 170 OVERALL DIAMETER 4.65 X 5.80 4.65 X 5.80 4.10 X 8.65 4.55 X 8.80 4.55 X 8.80 5.40 X 10.50 6.10 X 12.00 6.90 X 13.80 8.40 X 18.50 9.70 X 20.60 4.60 X 10.20 5.75 X 11.45 5.30 X 12.80 Should not be installed at temperatures below 0°C or above +40°C. Fixed = 3 x diameter Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES LSZH SURFACE WIRING CABLES LSZH 6181B FIXED WIRING AND MAINS CABLES LSZH 38 MAINS AND CONTROL CABLES LSZH Plain annealed stranded copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CODE LSF2X1/5 LSF3X1/5 LSF4X1/5 LSF5X1/5 LSF7X1/5 LSF12X1/5 LSF19X1/5 LSF27X1/5 LSF37X1/5 LSF48X1/5 LSF2X2/5 LSF3X2/5 LSF4X2/5 LSF5X2/5 LSF7X2/5 LSF12X2/5 LSF19X2/5 LSF27X2/5 LSF37X2/5 LSF48X2/5 LSF2X4 LSF3X4 LSF4X4 LSF5X4 LSF7X4 LSF12X4 LSF19X4 LSF27X4 LSF2X6 LSF3X6 LSF4X6 LSF5X6 LSF7X6 LSF2X10 LSF3X10 LSF4X10 LSF5X10 LSF7X10 LSF2X16 LSF3X16 LSF4X16 LSF5X16 LSF7X16 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 10.0 10.0 16.0 16.0 16.0 16.0 16.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 7/1.70 Temperature limits: -25 to +90°C *Bending radius: 6 x overall diameter. XLPE INSULATED LOW SMOKE ZERO HALOGEN MAINS AND CONTROL CABLE (1.5MM2 TO 16MM2) Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - Up to 6mm2 White with Black numbers. NO. OF CORES 2 3 4 5 7 12 19 27 37 48 2 3 4 5 7 12 19 27 37 48 2 3 4 5 7 12 19 27 2 3 4 5 7 2 3 4 5 7 2 3 4 5 7 WEIGHT OVERALL KG/KM DIAMETER (MM) 260 11 295 11.2 350 12.5 362 12.9 398 13.7 680 18 885 20.6 1310 25.1 1590 27.5 1958 31 270 12.2 360 12.8 410 13.5 435 14.7 520 15.6 905 21 1360 25 1760 30 2185 33 3003 37.3 381 13.1 435 13.7 495 14.8 583 16.35 760 18.2 1266 24.24 1701 27.61 2347 32.3 405 14.1 490 14.8 670 17.3 823 18.39 1100 21.9 600 16.1 750 17.9 885 19.3 1106 20.91 1500 25 905 19 990 20 1195 22 1695 25.19 2150 28.1 GLAND SIZE (MM) 20/16 20/16 20S 20S 20S 20 25 32 32 32 20S 20S 20S 20 20 25 32 32 40 40 20S 20S 20 20 20 25 32 40 20 20 20 20 25 20 20 25 25 25 25 25 25 25 32 SINGLE CLEAT 0.5 0.5 0.5 0.6 0.6 0.8 0.9 1.0 1.1 1.4 0.5 0.6 0.6 0.6 0.7 0.9 1.0 1.2 1.4 1.6 0.6 0.6 0.6 0.7 0.8 1.0 1.2 1.4 0.6 0.6 0.7 0.8 0.9 0.7 0.8 0.8 0.9 1.0 0.8 0.8 0.9 1.0 1.2 5 - 10mm2 and 16mm2 - Brown, Black, Grey, Blue, Green/Yellow. 1.5 & 2.5 - 2,3,4 core also available in white numbered cores to ESI 09-6 Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 39 Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 603323, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CODE LSF2X25 LSF3X25 LSF4X25 LSF5X25 LSF2X35 LSF3X35 LSF4X35 LSF5X35 LSF2X50 LSF3X50 LSF4X50 LSF5X50 LSF2X70 LSF3X70 LSF4X70 LSF5X70 LSF2X95 LSF3X95 LSF4X95 LSF5X95 LSF2X120 LSF3X120 LSF4X120 LSF5X120 LSF2X150 LSF3X150 LSF4X150 LSF5X150 LSF2X185 LSF3X185 LSF4X185 LSF2X240 LSF3X240 LSF4X240 LSF2X300 LSF3X300 LSF4X300 LSF3X400 LSF4X400 CONDUCTOR STRANDING SIZE (MM2) (MM) 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 120 150 150 150 150 185 185 185 240 240 240 300 300 300 400 400 7/2.14 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 NO. OF CORES 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 4 2 3 4 3 4 WEIGHT OVERALL KG/KM DIAMETER (MM) 1050 20 1500 23 1800 25 2200 29 1400 22 1800 26 2200 28 2800 33 1750 25 2250 28 2850 31 3850 38 2200 28 3000 32 4100 37 5100 43 3000 32 4150 37 5200 40 7700 52 3600 35 4950 40 6700 46 9030 56.7 4250 37 6300 45 7900 49 10752 64.31 5500 43 7650 49 9650 55 6900 48 9650 56 12400 62 8200 50 11550 59 14800 66 14350 65 19300 75 GLAND SIZE (MM) 25 25 32 32 25 32 32 40 32 32 32 40 32 32 40 50S 32 40 50S 50 40 50S 50 63S 40 50S 50 63 50S 50 63S 50 63S 63 50 63 75S 75S 75 SINGLE CLEAT 0.8 1.0 1.0 1.2 0.9 1.1 1.2 1.4 1.0 1.2 1.4 1.6 1.2 1.4 1.6 1.8 1.4 1.6 1.6 TC9 1.4 1.6 2.0 TC9 1.6 1.8 2.0 TC11 1.8 2.0 TC9 2.0 TC9 TC10 2.0 TC10 TC11 TC11 TC12 Temperature limits: -25 to +90°C. *Bending radius: 8 x overall diameter. XLPE INSULATED LOW SMOKE ZERO HALOGEN MAINS CABLE (25MM2 TO 400MM2) Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES LSZH MAINS CABLES LSZH FIXED WIRING AND MAINS CABLES LSZH 40 SINGLE CORE NON-ARMOURED MAINS CABLES LSZH Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CODE 6181B50 6181B70 6181B95 6181B120 6181B150 6181B185 6181B240 6181B300 6181B400 6181B500 6181B630 6181B800 6181B1000 CONDUCTOR STRANDING WEIGHT OVERALL BRASS SIZE (MM2) (MM) KG/KM DIAMETER A2 50 70 95 120 150 185 240 300 400 500 630 800 1000 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.52 61/3.20 127/2.52 127/2.85 127/3.20 525 730 990 1230 1525 1885 2440 3045 3855 4950 6345 8140 9860 13 15.5 18 19.5 21.5 24 27 29.5 33 37.5 42 47.5 53 25 25 25 32 32 32 40 40 50S 50S 50 63S 63 NYLON SINGLE A2 CLEAT (MM) 25 0.6 25 0.7 25 0.7 32 0.8 32 0.9 32 1.0 40 1.1 40 1.2 50 1.4 50 1.6 63 1.8 2.0 TC9 TREFOIL CLEAT 376AC04 376AC06 376AC09 376AC12 376AC15 376AC19 Temperature limits: -25 to +90°C. *Bending radius: 6 x overall diameter. Core identification: Brown inner/Black outer. Should not be installed at temperatures below 0°C or above +40°C. XLPE INSULATED LOW SMOKE ZERO HALOGEN SINGLE CORE NON-ARMOURED MAINS CABLE (50MM2 TO 1000MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 41 Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC CODE 6941AB50 6941AB70 6941AB95 6941AB120 6941AB150 6941AB185 6941AB240 6941AB300 6941AB400 6941AB500 6941AB630 6941AB800 6941AB1000 CONDUCTOR NO. OF WEIGHT OVERALLGLAND GLAND SINGLE TREFOIL CLEAT CLEAT SIZE(MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE ALI BRASS A2 (MM) (MM) 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 800.0 1000.0 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.2 127/2.52 127/2.85 127/3.2 1 1 1 1 1 1 1 1 1 1 1 1 1 638 891 1166 1412 1800 2200 2800 3400 4450 5550 7100 9200 11270 17.70 19.60 21.50 23.10 26.00 28.00 32.00 33.00 38.00 43.00 47.00 55.00 58.80 20 25 25 25 32 32 40 40 40 50S 50 63S 63S 25 32 32 32 40 40 50S 50S 50 63S 63S 75S 75S 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.4 1.6 1.8 2.0 TC9 TC10 376AC04 376AC06 376AC06 376AC10 376AC13 376AC15 376AC20 376AC22 Temperature limits: - 25 to + 90°C *Bending radius: 6 x Overall Diameter Core identification: Brown inner - Black outer Should not be installed at temperatures below 0°C or above +40°C. XLPE INSULATED LOW SMOKE ZERO HALOGEN SINGLE CORE ARMOURED MAINS CABLE (50MM2 TO 1000MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES LSZH SINGLE CORE ARMOURED MAINS CABLES LSZH FIXED WIRING AND MAINS CABLES LSZH 42 SCREENED FIXED WIRING AND MAINS CABLES TO BS 8436 Plain annealed stranded copper, XLPE insulated, tinned annealed stranded copper earth wire, bonded aluminium tube applied longitudinally, low smoke and zero halogen (LSZH) outer sheath, to BS EN 50267-1:1998 and BS EN 50268-2:2000, UV Stable. 600/1000v to BS8436, White. Acid gas emissions to BS EN 50267-2-1, smoke emissions to BS EN 50268-2 and flame retardant to BS EN 60332-1-2 (IEC 60332-1-1). CCC CODE FSX2X1WH FSX3X1WH FSX4X1WH FSX2X1/5WH FSX3X1/5WH FSX4X1/5WH FSX2X2/5WH FSX3X2/5WH FSX4X2/5WH FSX2X4WH FSX3X4WH FSX4X4WH FSX2X6WH FSX3X6WH FSX4X6WH FSX2X10WH CONDUCTOR STRANDING SIZE (MM2) (MM) 1.0 1.0 1.0 1.5 1.5 1.5 2.5 2.5 2.5 4 4 4 6 6 6 10 NO. OF CORES 7/0.44 7/0.44 7/0.44 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.35 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 WEIGHT OVERALL KG/KM DIAMETER (MM) 85 8.60 105 9.40 130 10.00 106 9.80 140 10.40 158 11.30 135 10.80 182 11.10 259 12.60 206 11.50 265 13.10 320 13.90 258 13.10 328 14.20 450 14.90 413 16.1 1 HOLE CLIP REF RCHL34 RCHL37 RCHL37 RCHL37 RCHL40 RCHL43 RCHL43 RCHL43 RCHL47 RCHL43 RCHL51 RCHL54 RCHL51 RCHL54 RCHL59 RCHL63 GLAND REF 20SA2 20SA2 20A2 20A2 20A2 20A2 20A2 20A2 20A2 20A2 25A2 25A2 25A2 25A2 25A2 25A2 Minimum installation temperature: -10°C. Maximum continuous conductors operating temperature: +90°C. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Solid cores available on request. Different sheath and core colours available on request. 10mm2 and 16mm2 available on request Also available in 300/500 volt rating. MECHANICALLY PROTECTED WIRING CABLE Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 43 FIXED WIRING AND MAINS CABLES FIXED WIRING AND MAINS CABLES 11000V, 22000V, AND 33000V FIXED WIRING AND MAINS CABLES 44 SINGLE CORE ARMOURED MAINS CABLES PVC 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, copper tape screen, PVC bedding, aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION (MM) (MM) REFERENCE 10001 50 19/1.78 1 1200 28.7 32 12 376AC04 EPKT 17B1XI 10002 70 19/2.14 1 1461 30.5 32 14 376AC05 EPKT 17B1XI 10003 95 19/2.52 1 1761 32.2 32 14 376AC06 EPKT 17C1XI 10004 120 37/2.03 1 2049 33.8 40 14 376AC07 EPKT 17C1XI 10005 150 37/2.25 1 2451 36.2 40 16 376AC08 EPKT 17C1XI 10006 185 37/2.52 1 2848 37.9 40 16 376AC09 EPKT 17C1XI 10007 240 61/2.25 1 3470 40.4 50S 16 376AC11 EPKT 17C1XI 10008 300 61/2.52 1 4103 42.6 50S 18 376AC12 EPKT 17D1XI 10009 400 61/2.85 1 4995 45.6 50S 18 376AC14 EPKT 17D1XI 10010 500 61/3.20 1 6320 50 50 20 376AC17 EPKT 17E1XI 10011 630 127/2.52 1 7840 54 63S TC9 376AC19 EPKT 17E1XI SINGLE CORE (50MM2 TO 630MM2) AND 3 CORE (25MM2 TO 400MM2) XLPE INSULATED MEDIUM VOLTAGE MAINS CABLES 11000 VOLT Temperature limits: up to 90°C. *Bending radius: Should not be installed at temperatures below 0°C or above +60°C. 12 x overall diameter. Core identification: Brown. 3 CORE MAINS CABLES PVC 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CODE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT TERMINATION (MM) (MM) REFERENCE 11KV XLPE3X25RD 25 7/2/14 3 4300 48.4 50 2.0 EPKT 17A3XIH2 11KV XLPE3X35RD 35 19/1/53 3 4491 50.5 50 2.0 EPKT 17B3XIH2 11KV XLPE3X50RD 50 19/1/78 3 5105 53.3 63S TC9 EPKT 17B3XIH2 11KV XLPE3X70RD 70 19/2/14 3 6019 56.9 63S TC9 EPKT 17B3XIH2 11KV XLPE3X95RD 95 19/2/52 3 7148 61 63 TC10 EPKT 17C3XIH2 11KV XLPE3X120RD 120 37/2/03 3 8199 64.6 75S TC11 EPKT 17C3XIH2 11KV XLPE3X150RD 150 37/2/25 3 9274 67.8 75S TC11 EPKT 17C3XIH2 11KV XLPE3X185RD 185 37/2/52 3 10706 71.9 75 TC12 EPKT 17C3XIH2 11KV XLPE3X240RD 240 61/2/25 3 13740 78.8 90 TC14 EPKT 17C3XIH2 11KV XLPE3X300RD 300 61/2/52 3 16051 84.1 90 TC14 EPKT 1D3XIH2 11KV XLPE3X400RD 400 61/2/85 3 19095 90.3 TC15 EPKT 17D3XIH2 Temperature limits: up to 90°C. *Bending radius: Should not be installed at temperatures below 0°C or above +60°C. 12 x overall diameter. Core identification: Brown, Black, Grey tapes. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 45 Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding (extruded), galvanised steel wire armour, PVC outer sheath. Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CODE 10115RD 10116RD 10117RD 10118RD 10119RD 10120RD CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 95 19/2.52 3 5800 62.6 63 TC10 120 37/2.03 3 6400 66.6 75S TC11 150 37/2.25 3 7000 68.6 75S TC11 185 37/2.52 3 7800 74.1 75 TC12 240 61/2.25 3 9800 81.2 90 TC14 300 61/2.52 3 11000 86.8 90 TC15 RAYCHEM TERMINATION REFERENCE EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17D3XIH2 Temperature limits: up to 90°C. *Bending radius: 13 x overall diameter. Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C or above +60°C. XLPE INSULATED MEDIUM VOLTAGE MAINS CABLE 11000 VOLT (95MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES 3 CORE MAINS CABLES PVC 11000V FIXED WIRING AND MAINS CABLES 46 TRIPLEX CABLES 11000V Solid or stranded aluminium conductor, XLPE insulated, copper wire screen (35mm2). MDPE outer sheath. Red. 6350/11000 volts grade to BS7870. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CODE CONDUCTOR CONDUCTOR NOMINAL SIZE (MM2) TYPE CONDUCTOR DIAMETER 11KVTRIP3X70AL 70 SOLID 9.30 11KVTRIP3X70AL 70 STRANDED 9.80 11KVTRIP3X95AL 95 SOLID 10.70 11KVTRIP3X95AL 95 STRANDED 12.16 11KVTRIP3X185AL 185 SOLID 14.90 11KVTRIP3X185AL 185 STRANDED 15.80 11KVTRIP3X300AL 300.0 SOLID 19.00 11KVTRIP3X300AL 300.0 STRANDED 20.50 NO. OF CORES WEIGHT KG/KM 3 3 3 3 3 3 3 3 2763 2650 3055 2901 4095 4060 5374 5360 DIAMETER IN TRIPLEX FORMATION 57.4 58.3 60.8 57.83 70.5 72.5 80.4 81.4 Temperature limits: -15 to +90°C. *Bending radius: 15 x overall diameter. Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C. 3 CORE UTILITY CABLE TRIPLEX FORMATION XLPE INSULATED MEDIUM VOLTAGE CABLE 11000 VOLT (70MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 47 COPPER CONDUCTOR Plain annealed copper conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CODE PILC3X25RD PILC3X35RD PILC3X50RD PILC3X70RD PILC3X95RD PILC3X120RD PILC3X150RD PILC3X185RD PILC3X240RD PILC3X300RD PILC3X400RD CONDUCTOR STRANDING SIZE (MM2) (MM) 25 35 50 70 95 120 150 185 240 300 400 7/2.14 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 No. OF CORES 3 3 3 3 3 3 3 3 3 3 3 Temperature limits: up to 65°C. *Bending radius: PAPER INSULATED MEDIUM VOLTAGE MAINS CABLE 11000 VOLT (25MM2 TO 400MM2) WEIGHT OVERALL KG/KM DIAMETER (MM) 5230 43.6 5890 42.3 6620 45.6 7820 49.7 9240 53.3 10400 56.2 11770 59.2 13550 62.8 16390 67.8 19870 73.6 23700 79.4 SINGLE RAYCHEM CLEAT TERMINATION REFERENCE 1.8 EPKT 17A3MIH2 2.0 EPKT 17B3MIH2 2.0 EPKT 17B3MIH2 2.0 EPKT 17B3MIH2 TC9 EPKT 17C3MIH2 TC9 EPKT 17C3MIH2 TC10 EPKT 17C3MIH2 TC10 EPKT 17C3MIH2 TC11 EPKT 17C3MIH2 TC12 EPKT 17D3MIH2 TC14 EPKT 17D3MIH2 Should not be installed at temperatures below 0°C or above +60°C. 13 x overall diameter. Core identification: White printed numbers on insulating papers. ALUMINIUM CONDUCTOR Plain aluminium stranded conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC CODE 10100RD 10103RD 10105RD CONDUCTOR STRANDING SIZE (MM2) (MM) 95 185 300 19/2.52 37/2.52 61/2.52 No. OF CORES 3 3 3 WEIGHT OVERALL KG/KM DIAMETER (MM) 7115 53.2 9521 63.5 13403 71.5 SINGLE RAYCHEM CLEAT TERMINATION REFERENCE TC9 EPKT 17C3MIH2 TC11 EPKT 17C3MIH2 TC12 EPKT 17D3MIH2 Temperature limits: up to 65°C. *Bending radius: Core identification: White printed numbers on insulating papers. 13 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES PAPER INSULATED MAINS CABLES PVC 11000V FIXED WIRING AND MAINS CABLES 48 SINGLE CORE ARMOURED MAINS CABLES LSZH 11000V Stranded plain annealed compacted circular copper conductor, XLPE insulated, semi-conducting tape insulated, copper tape screen, low smoke and zero halogen (LSZH) bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor U.V resistant qualities, red outer sheath cables are not recomended for outdoor installation. SINGLE CORE (50MM2 TO 630MM2) AND 3 CORE (25MM2 TO 400MM2) XLPE INSULATED LOW SMOKE ZERO HALOGEN MEDIUM VOLTAGE MAINS CABLES 11000 VOLT CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM CODE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION (MM) (MM) REFERENCE 10050 50 19/1.78 1 1200 28.7 32 12 376AC04 EPKT 17B1XI 10051 70 19/2.14 1 1461 30.5 32 14 376AC05 EPKT 17B1XI 10052 95 19/2.52 1 1761 32.2 32 14 376AC06 EPKT 17C1XI 10053 120 37/2.03 1 2049 33.8 40 14 376AC07 EPKT 17C1XI 10054 150 37/2.25 1 2451 36.2 40 16 376AC08 EPKT 17C1XI 10055 185 37/2.52 1 2848 37.9 40 16 376AC09 EPKT 17C1XI 10056 240 61/2.25 1 3470 40.4 50S 16 376AC11 EPKT 17C1XI 10057 300 61/2.52 1 4103 42.6 50S 18 376AC12 EPKT 17D1XI 10058 400 61/2.85 1 4995 45.6 50S 18 376AC14 EPKT 17D1XI 10059 500 61X3.20 1 6320 50 50 20 376AC17 EPKT 17E1XI 10060 630 127X2.52 1 7840 54 63S TC9 376AC19 EPKT 17E1XI Temperature limits: up to 90°C. *Bending radius: Should not be installed at temperatures below 0°C or above +40°C. 15 x overall diameter. Core identification: Brown. 3 CORE MAINS CABLES LSZH 11000V Stranded plain annealed compacted circular copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor U.V resistant qualities red outer sheath cables are not recomended for outdoor installation. CCC CODE 10302RD 10304RD 10306RD 10308RD 10310RD 10312RD 10314RD 10316RD 10318RD 10320RD CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLEAT (MM) (MM) 35 19/1.53 3 4501 50.5 50 TC9 50 19/1.78 3 5117 53.3 63S TC9 70 19/2.14 3 6032 56.9 63S TC9 95 19/2.52 3 7163 61 63 TC10 120 37/2.03 3 8216 64.6 75S TC11 150 37/2.25 3 9292 67.8 75 TC11 185 37/2.52 3 10726 71.9 75 TC12 240 61/2.25 3 13763 78.8 90 TC14 300 61/2.52 3 16077 84.1 90 TC14 400 70/3.15 3 19124 90.3 TC15 Temperature limits: up to 90°C. *Bending radius: RAYCHEM TERMINATION REFERENCE EPKT 17B3XIH2 EPKT 17B3XIH2 EPKT 17B3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17C3XIH2 EPKT 17D3XIH2 - Should not be installed at temperatures below 0°C or above +40°C. 12 x overall diameter. Core identification: Brown, Black, Grey tapes. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 49 Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(LSZH) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red. 12700/22000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC CODE CONDUCTOR SIZE (MM) 22KVXLPE3X95RD 95.0 STRANDING 19/2.52 Temperature limits: - 15 to + 90°C NO. OF CORES 3 WEIGHT (KG/KM) 8820 OVERALL DIAMETER 70.30 Should not be installed at temperatures below 0°C or above +40°C. *Bending radius: 12 x overall diameter Core identification: Brown, Black, Grey tapes. Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(LSZH) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red. 19000/33000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC CONDUCTOR CODE SIZE (MM) 33KVLSF3X95RD 95.0 33KVLSF3X185RD 185.0 Temperature limits: - 15 to + 90°C *Bending radius: STRANDING 19/2.52 37/2.52 NO. OF CORES 3 3 WEIGHT (KG/KM) 12020 20000 OVERALL DIAMETER 85.30 96.00 Should not be installed at temperatures below 0°C or above +40°C. 12 x overall diameter Core identification: Brown, Black, Grey tapes. 3 CORE XLPE INSULATED LOW SMOKE ZERO HALOGEN MEDIUM VOLTAGE MAINS CABLE 22000 VOLT (95MM2) AND 33000 VOLT (95MM2 / 185MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES THREE CORE MAINS CABLES 22KV AND 33KV 51 FIXED WIRING AND MAINS CABLES FIXED WIRING AND MAINS CABLES 33000V - SERVICE AND WINDFARM FIXED WIRING AND MAINS CABLES 52 SINGLE CORE MAINS CABLE MDPE 33000V WINDFARM CABLE Round stranded compacted aluminium conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape seperator, extruded black MDPE outer sheath. 33000 volts grade to BS7870, IEC 60502-2. CCC CODE 33KV1X70AL 33KV1X95AL 33KV1X120AL 33KV1X150AL 33KV1X185AL 33KV1X240AL 33KV1X300AL 33KV1X400AL 33KV1X500AL 33KV1X630AL CONDUCTOR SIZE (MM) 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 STRANDING 19/2.1 19/2.47 35/2.04 35/2.27 35/2.54 35/2.91 35/3.25 56/2.91 56/3.3 56/3.75 Rated voltage Uo/U Max operating voltage Test voltage Partial discharge level with voltage 2Uo Kv Max. perm conductor temperature Max. perm operating temperature Short circuit temperature *Minimum bending radius SINGLE CORE 33000 VOLT RATED WINDFARM CABLE ALUMINIUM CONDUCTOR (70MM TO 630MM) NO. OF CORES 1 1 1 1 1 1 1 1 1 1 WEIGHT (KG/KM) 1339 1467 1584 1720 1881 2130 2381 2723 3146 3675 OVERALL DIAMETER 36.70 38.40 39.80 41.30 43.00 45.50 47.80 50.80 54.30 58.90 19/33 Kv 36 kv 75 kv max. 5pC 90°C 130°C 250°C 12 x overall diameter Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 53 Round stranded compacted copper conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape seperator, extruded black MDPE outer sheath. 33000 volts grade to BS7870, IEC 60502-2. CCC CONDUCTOR CODE SIZE (MM) 33KVCU1X70BK 70.0 33KVCU1X95BK 95.0 33KVCU1X120BK 120.0 33KVCU1X150BK 150.0 33KVCU1X185BK 185.0 33KVCU1X240BK 240.0 33KVCU1X300BK 300.0 33KVCU1X400BK 400.0 33KVCU1X500BK 500.0 33KVCU1X630BK 630.0 STRANDING 19/2.11 19/2.48 35/2.05 35/2.28 35/2.55 35/2.92 35/3.28 56/2.93 56/3.32 56/3.77 Rated voltage Uo/U Max operating voltage Test voltage Partial discharge level with voltage Max. perm conductor temperature Max. perm operating temperature Short circuit temperature *Minimum bending radius SINGLE CORE 33000 VOLT RATED SERVICE CABLE COPPER CONDUCTOR (70MM TO 630MM) NO. OF CORES 1 1 1 1 1 1 1 1 1 1 WEIGHT (KG/KM) 1751 2043 2309 2614 2997 3596 4225 5069 6156 7570 OVERALL DIAMETER 36.50 38.20 39.60 41.20 42.90 45.40 47.80 50.60 53.90 57.60 19/33 Kv 36 kv 75 kv 2Uo Kv max. 5pC 90°C 130°C 250°C 12 x overall diameter Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIXED WIRING AND MAINS CABLES SINGLE CORE MAINS CABLE MDPE 33000V SERVICE CABLE 55 FIREPROOF CABLES FIREPROOF CABLES FIREPROOF CABLES 56 FIREPROOF CABLES - MINERAL INSULATED Solid plain annealed copper conductors, magnesium oxide insulated, solid copper sheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options: (a) Light Duty = 500 volts grade Heavy Duty = 1000 volts grade (b) Outer sheath finishes, bare copper, PVC or LSZH (c) Outer sheath colours. Orange, Red, White or Black. SIZE REF. 2L1.0 2L1.5 2L2.5 2L4.0 3L1.0 3L1.5 3L2.5 4L1.0 4L1.5 4L2.5 7L1.5 7L2.5 1H6.0 1H10 1H16 1H25 1H35 1H50 1H70 1H95 1H120 1H150 1H240 2H1.5 2H2.5 2H4.0 2H6.0 2H10 2H16 2H25 3H1.5 3H2.5 3H4.0 3H6.0 3H10 3H16 3H25 4H1.5 4H2.5 4H4.0 4H6.0 4H10 4H16 4H25 7H1.5 7H2.5 12H2.5 19H1.5 BARE SHEATHED OVERALL OVERALL GLAND KG/KM KG/KM DIAMETER DIAMETER FOR USE BARE SHEATHED WITH RPS (MM) (MM) SEALS 104.0 125.00 5.1 6.6 20 136.0 159.00 5.7 7.2 20 187.0 213.00 6.6 8.1 20 248.0 282.00 7.7 9.4 20 136.0 159.00 5.8 7.3 20 176.0 201.00 6.4 7.9 20 223.0 256.00 7.3 9 20 162.0 187.00 6.3 7.8 20 203.0 230.00 7 8.5 20 277.0 313 8.1 9.8 20 295.0 332 8.4 10.1 25 411.0 454 9.7 11.4 25 173.0 213 6.4 7.7 20 240 273 7.3 9 20 326 361 8.3 10 20 457 499 9.6 11.3 20 585 632 10.7 12.4 20 758 810 12.1 13.8 25 1016 1075 13.7 15.4 25 1324 1413 15.4 17.7 25 1612 1709 16.8 19.1 32 1949 2055 18.4 20.7 32 3050 3213 23.3 26.1 40 237 272 7.9 9.6 20 276 314 8.7 10.4 20 355 397 9.8 11.5 20 446 493 10.9 12.6 20 619 673 12.7 14.4 25 850 912 14.7 16.4 25 1178 1277 17.1 19.4 32 254 290 8.3 10 20 323 364 9.3 11 20 415 460 10.4 12.1 20 526 575 11.5 13.2 25 754 812 13.6 15.3 25 1034 1124 15.6 17.9 25 1444 1549.00 18.2 20.5 40 305 345.00 9.1 10.8 20 384 428.00 10.1 11.8 20 507 556.00 11.4 13..1 25 644 698.00 12.7 14.4 25 911 974.00 14.8 16.5 25 1286 1386.00 17.3 19.6 32 1805 1947.00 20.1 22.9 40 432 479.00 10.8 12.5 25 559 611.00 12.1 13.8 25 911 1001.00 15.6 17.9 32 992 1088.00 16.6 18.9 40 Temperature limits: PVC sheath -20 to +70°C. LSF sheath -20 to +80°C. MINERAL INSULATED CABLE (1.0MM2 TO 240MM2) SINGLE HOLE CLIP NOMINAL REFERENCE STD DRUM BARE SHEATHED LTHS (MTS) 20 22 26 30 22 24 28 24 28 32 32 37 34 28 32 37 40 47 54 59 63 71 88 30 34 37 43 47 54 67 32 37 40 43 54 59 71 37 40 43 47 54 67 79 43 47 59 63 26 28 32 37 28 30 34 30 34 37 40 43 34 34 37 43 47 54 59 67 75 79 101 37 40 43 47 54 63 75 37 43 47 51 59 71 79 43 47 51 54 63 75 88 47 54 71 71 500 500 500 500 500 500 500 500 500 500 380 285 650 510 400 275 222 170 190 155 135 110 67 500 500 500 500 500 112 80 500 500 500 184 130 100 70 500 500 195 144 110 89 60 245 195 148 112 *Bending radius: 6 x overall diameter. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 57 Plain annealed copper conductor, silicon rubber insulated aluminium/polyester tape screen, tinned annealed copper earth wire, low smoke zero halogen (LSZH) outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387. Flame retardant to BS5839-1:2003 and IEC 60332-3 CAT CWZ, BS7629-1 1997. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). CCC CODE FP2X1 FP3X1 FP4X1 FP7X1 FP12X1 FP2X1/ 5 FP3X1/ 5 FP4X1/5 FP7X1/5 FP12X1/5 FP19X1/5 FP2X2/5 FP3X2/5 FP4X2/5 FP7X2/5 FP12X2/5 FP19X2/5 FP2X4 FP3X4 FP4X4 CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND SIZE (MM2) (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF (MM) (MM) 1.0 1/1.13 2+E 90 7.5 20 28 251 1.0 1/1.13 3+E 110 8.0 20 30 251 1.0 1/1.13 4+E 135 8.8 20 34 251 1.0 1/1.13 7+E 170 10.5 20 40 252 1.0 1/1.13 12+E 270 13.7 25 54 254 1.5 1/1.38 2+E 110 8.0 20 32 251 1.5 1/1.38 3+E 130 8.4 20 34 251 1.5 1/1.38 4+E 160 9.5 20 37 251 1.5 1/1.38 7+D 230 11.3 20 43 252 1.5 1/1.38 12+D 365 15.2 25 59 254 1.5 1/1.38 19+D 540 17.8 25 67 254 2.5 1/1.78 2+E 160 9.0 20 34 252 2.5 1/1.78 3+E 200 10.5 20 40 252 2.5 1/1.78 4+E 250 11.7 20 43 252 2.5 1/1.78 7+D 285 13.7 20 54 252 2.5 1/1.78 12+D 470 17.9 25 67 254 2.5 1/1.78 19+D 720 21.4 32 79 255 4.0 7/0.85 2+E 260 11.3 20 43 252 4.0 7/0.85 3+E 315 12.1 25 47 254 4.0 7/0.85 4+E 380 13.3 25 54 254 E = Bare earth conductor. D = Drain wire Temperature limits: -10 to +80°C. *Bending radius: 6 x overall diameter. FIRE RESISTANT FIRE ALARM & SECURITY CABLE STANDARD (1.0MM2 TO 4MM2) Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 7 core and above - White with Black numbers. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIREPROOF CABLES STANDARD FIRE ALARM AND SECURITY WIRING CABLES FIREPROOF CABLES 58 ENHANCED FIRE ALARM AND SECURITY WIRING CABLES Plain annealed copper conductor, enhanced silicon rubber insulated, enhanced aluminium/polyester tape screen, tinned annealed copper earth wire, enhanced low smoke zero halogen outer sheath. Red or white. Manufactured to meet the Enhanced standard of BS5839-1 2002 +A2:2008 Clause 26.2e Enhanced and also the requirements of BS8434 - 2:2003 120 minutes and BS EN 50200 Class PH120. Fire resistant to BS7629-1:2008, BS6387:1994 clause 11 CWZ, halogen emissions to bs en 50267-2-1:1999 and low smoke standard BS EN 61034-2:2005. CCC CODE ENH2X1/5 ENH3X1/5 ENH4X1/5 ENH2X2/5 ENH3X2/5 ENH4X2/5 ENH2x4 ENH3x4 ENH4x4 CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND (MM) CORES KG/KM DIAMETER SIZE CLIP REF REF SIZE (MM2) (MM) (MM) 1.5 1/1.38 2+E 110 8.0 20 32 251 1.5 1/1.38 3+E 130 8.4 20 34 251 1.5 1/1.38 4+E 160 9.5 20 37 251 2.5 1/1.78 2+E 160 9.0 20 34 252 2.5 1/1.78 3+E 200 10.5 20 40 252 2.5 1/1.78 4+E 250 11.7 20 43 252 4.0 7/0.85 2+E 260 11.3 20 43 252 4.0 7/0.85 3+E 315 12.1 25 47 254 4.0 7/0.85 4+E 380 13.3 25 51 254 E = Bare earth conductor. Temperature limits: -40 to +90°C. *Bending radius: 6 x overall diameter. FIRE RESISTANT FIRE ALARM & SECURITY CABLE ENHANCED (1.5MM2 TO 4MM2) Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 59 Plain annealed copper conductor, mica fire resistant tape, low smoke zero halogen (LSZH) insulation. 600/1000 volts grade. Fire resistant to IEC 331 and BS6387, CWZ when tested in steel conduit. Manufactured to meet the following standards - acid gas emission to BS EN 50267, flame retardant to BS EN 60332-1-2 and smoke emission to BS7211. CCC CODE 6491F1/5 6491F2/5 6491F4 6491F6 6491F10 6491F16 CONDUCTOR SIZE (MM) 1.5 2.5 4.0 6.0 10.0 16.0 STRANDING 7/0.53 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 NO. OF CORES 1 1 1 1 1 1 WEIGHT (KG/KM) 32 43 55 85 146 198 OVERALL DIAMETER 3.30 3.75 4.30 5.00 6.80 8.00 Temperature limits: - 40 to + 90°C *Bending radius: 8 x Overall Diameter Standard colours available: Brown, Blue, Grey, Black, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. FIRE RESISTANT SINGLE CORE CABLES (1.5MM2 TO 16MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIREPROOF CABLES FIREPROOF CABLES - SINGLES FIREPROOF CABLES 60 FIREPROOF MAINS AND CONTROL CABLES LSZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke & zero halogen (LSZH) outer sheath. Black. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2 / BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3). CCC CODE 6942F1/5 6943F1/5 6944F1/5 6947F1/5 6940/12F1/5 6940/19F1/5 6940/27F1/5 6940/37F1/5 6942F2/5 6943F2/5 6944F2/5 6947F2/5 6940/12F2/5 6940/19F2/5 6940/27F2/5 6940/37F2/5 6942F4 6943F4 6944F4 6945F4 6947F4 6942F6 6943F6 6944F6 6945F6 6942F10 6943F10 6944F10 6945F10 6942F16 6943F16 6944F16 6945F16 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 6 6 6 6 10 10 10 10 16 16 16 16 NO. OF CORES 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 2 3 4 7 12 19 27 37 2 3 4 7 12 19 27 37 2 3 4 5 7 2 3 4 5 2 3 4 5 2 3 4 5 WEIGHT OUTSIDE KG/KM DIAMETER (MM) 295 12.00 324 12.50 367 13.30 463 15.30 791 20.00 1030 22.90 1534 27.90 1849 30.70 352 13.10 392 13.70 454 14.70 584 17.00 1003 22.50 1525 27.00 1990 31.60 2435 34.80 424 14.10 478 14.80 556 16.00 725 18.12 852 19.50 504 15.20 573 16.00 783 18.20 865 19.65 620 16.90 868 18.50 1029 20.00 1222 22.64 954 19.50 1136 20.80 1367 22.50 1812 26.55 GLAND SIZE (MM) 20/16 20/16 20S 20S 25 25 32 32 20S 20S 20S 20 25 32 32 40 20S 20S 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 SINGLE CLEAT 0.5 0.6 0.6 0.7 0.8 1.0 1.2 1.4 0.6 0.6 0.6 0.7 0.9 1.1 1.4 1.4 0.6 0.6 0.7 0.8 0.8 0.7 0.7 0.8 0.8 0.7 0.8 0.8 0.9 0.8 0.9 0.9 1.1 Temperature limits: -40 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above 4mm2 and 6mm2 White with Black numbers. 5 core - 10mm2 and 16mm2 - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. FIRE RESISTANT POWER AND CONTROL CABLE (1.5MM2 TO 16MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 61 Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade. Fire resistant to BS6387/BS7846 F2 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3). CCC CODE FP2X25 FP3X25 FP4X25 FP5X25 FP2X35 FP3X35 FP4X35 FP2X50 FP3X50 FP4X50 FP2X70 FP3X70 FP4X70 FP2X95 FP3X95 FP4X95 FP2X120 FP3X120 FP4X120 FP2X150 FP3X150 FP4X150 FP2X185 FP3X185 FP4X185 FP2X240 FP3X240 FP4X240 FP2X300 FP3X300 FP4X300 FP3X400 FP4X400 CONDUCTOR STRANDING SIZE (MM2) (MM) 25 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 400 7/2.14 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 NO. OF CORES 2 3 4 5 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 WEIGHT OVERALL KG/KM DIAMETER (MM) 1100 21.4 1800 26.6 2150 28.8 2700 32 1550 24.3 2200 29.1 2650 31.6 1850 26.8 2450 29.6 3100 33.2 2450 30 3200 33.3 4400 38.9 3350 34.1 4450 38.1 5650 42.9 3900 37.1 5300 41.5 7250 48.3 4650 40.3 6700 46.6 8550 52.6 5950 45.7 8050 50.9 10300 57.8 7350 50 9950 56.2 12900 64.2 8700 54.5 12050 61.3 15550 70 14800 67.7 20250 79.3 GLAND SIZE (MM) 25 32 32 32 25 32 32 32 32 40 32 40 40 40 40 50S 40 50S 50 50S 50 50 50 50 63S 50 63S 63 63S 63 75S 75S 90 SINGLE CLEAT 0.9 1.1 1.2 1.4 1.0 1.2 1.4 1.1 1.2 1.4 1.4 1.4 1.6 1.4 1.6 1.8 1.6 1.8 2.0 1.8 2.0 TC9 2.0 TC9 TC10 TC9 TC9 TC11 TC9 TC10 TC12 TC11 TC14 Temperature limits: -40 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. FIRE RESISTANT POWER CABLE (25MM2 TO 400MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIREPROOF CABLES FIREPROOF MAINS CABLES LSZH FIREPROOF CABLES 62 FIREPROOF MAINS AND CONTROL CABLES LSZH - ENHANCED Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer sheath.Black. 600/1000 grade volts. Manufactured to meet the following standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC 60332-3, BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN 50268. CCC CODE FPE2X4 FPE3X4 FPE4X4 FPE2X6 FPE3X6 FPE4X6 FPE2X10 FPE3X10 FPE4X10 FPE2X16 FPE3X16 FPE4X16 CONDUCTOR SIZE (MM) STRANDING 4.0 7/0.85 4.0 7/0.85 4.0 7/0.85 6.0 7/1.04 6.0 7/1.04 6.0 7/1.04 10.0 7/1.35 10.0 7/1.35 10.0 7/1.35 16.0 7/1.7 16.0 7/1.7 16.0 7/1.7 Temperature limits: - 40 to + 90°C *Bending radius: NO. OF CORES 2 3 4 2 3 4 2 3 4 2 3 4 WEIGHT OVERALL GLAND (KG/KM) DIAMETER SIZE (MM) 871 21.80 25 966 22.70 25 959 24.00 25 1001 23.00 25 1087 23.80 25 1252 25.20 25 1060 23.80 20 1180 24.80 25 1350 27.40 32 1290 25.90 25 1460 27.10 32 1690 28.98 32 SINGLE CLEAT 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.2 Should not be installed at temperatures below 0°C or above 40°C. 8 x Overall Diameter Core identification: 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. FIRE RESISTANT POWER AND CONTROL CABLE - ENHANCED (4MM2 TO 16MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 63 Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer sheath.Black. 600/1000 grade volts. Manufactured to meet the following standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC 60332-3, BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN 50268. CCC CODE FPE2X25 FPE3X25 FPE4X25 FPE2X35 FPE3X35 FPE4X35 FPE2X50 FPE3X50 FPE4X50 FPE2X70 FPE3X70 FPE4X70 FPE2X95 FPE3X95 FPE4X95 FPE2X120 FPE3X120 FPE4X120 FPE2X150 FPE3X150 FPE4X150 FPE2X185 FPE3X185 FPE4X185 FPE2X240 FPE3X240 FPE4X240 FPE2X300 FPE3X300 FPE4X300 FPE3X400 FPE4X400 CONDUCTOR SIZE (MM) STRANDING 25 7/2.14 25 7/2.14 25 7/2.14 35 7/2.52 35 7/2.52 35 7/2.52 50 19/1.78 50 19/1.78 50 19/1.78 70 19/2.14 70 19/2.14 70 19/2.14 95 19/2.52 95 19/2.52 95 19/2.52 120 37/2.03 120 37/2.03 120.0 37/2.03 150.0 37/2.25 150.0 37/2.25 150.0 37/2.25 185.0 37/2.52 185.0 37/2.52 185.0 37/2.52 240.0 61/2.25 240.0 61/2.25 240.0 61/2.25 300.0 61/2.52 300.0 61/2.52 300.0 61/2.52 400.0 61/2.85 400.0 61/2.85 Temperature limits: - 40 to + 90°C *Bending radius: NO. OF CORES 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 WEIGHT OVERALL GLAND (KG/KM) DIAMETER SIZE (MM) 1640 29.00 32 2070 31.10 32 2410 33.40 40 2130 31.90 32 2480 33.50 40 2920 36.10 40 2030 29.90 32 2630 33.20 40 3280 37.10 40 2580 33.30 40 3400 37.00 40 4570 45.50 50 3440 37.20 40 4550 41.20 50S 5720 46.40 50 4050 39.90 50S 5410 44.40 50S 7270 51.20 50 4740 43.10 50S 6800 49.30 50 8580 55.70 63S 6050 48.10 50 8140 53.70 63S 10300 60.80 63 7390 52.40 50 10040 58.80 63 12800 66.50 75S 8760 56.50 63S 12020 63.50 63 15410 72.10 75 14820 70.10 75S 19910 81.30 90 SINGLE CLEAT 1.2 1.4 1.6 1.4 1.4 1.6 1.2 1.4 1.6 1.4 1.6 1.8 1.6 1.8 2.0 1.6 1.8 TC9 1.8 2.0 TC9 2.0 TC9 TC10 TC9 TC10 TC11 TC9 TC10 TC12 TC12 TC14 Should not be installed at temperatures below 0°C or above 40°C. 8 x Overall Diameter Core identification: 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. FIRE RESISTANT POWER AND CONTROL CABLE - ENHANCED (25MM2 TO 400MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FIREPROOF CABLES FIREPROOF MAINS CABLES LSZH - ENHANCED 65 FLEXIBLE CABLES FLEXIBLE CABLES FLEXIBLE CABLES 66 PVC INSULATED FLEXIBLE CORDS 218*Y - 318*Y Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath. Black or White. 300/500 volts grade to BS6500. (Harmonized code HO5VV-F). Flame propagation to BS EN 50265. CCC CODE **2182Y/5 **2182Y/75 **2183Y/5 **2183Y/75 3182Y/5 3183Y/5 3182Y/75 3183Y/75 3184Y/75 3185Y/75 3182Y1 3183Y1 3184Y1 3185Y1 3182Y1/5 3183Y1/5 3184Y1/5 3185Y1/5 3182Y2/5 3183Y2/5 3184Y2/5 3185Y2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.75 0.5 0.75 0.5 0.5 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 16/0.2 24/0.2 16/0.2 24/0.2 16/0.2 16/0.2 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 Temperature limits: Fixed - -5 to +60°C. Flexing - +5 to +60°C. *Bending radius: Fixed 2 x overall diameter. Flexing 6 x overall diameter. NO. OF CORES WEIGHT KG/KM 2 2 3 3 2 3 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 36 45 44 55 52 54 59 70 85 110 69 82 105 130 95 120 150 180 145 180 220 265 OVERALL DIAMETER (MM) 5.4 5.8 5.6 6.1 6.3 6.3 6.8 7.2 7.7 8.5 7.2 7.6 8.5 9.1 8.2 8.9 10.0 11.0 9.9 10.8 11.3 12.8 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20S 20/16 20/16 20S 20S 20/16 20S 20S 20 20S 20S 20 20 Should not be installed at temperatures below 0°C. **Light flexible cords 300/300 volts grade Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. PVC INSULATED FLEXIBLE CORDS TYPE 218*Y & 318*Y (0.5MM2 TO 2.5MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 67 Plain annealed flexible copper conductors heat resisting PVC outer sheath. White 300/500 volts grade to BS6141. Flame propagation to BS EN 50265. CCC CODE 3092Y/5 3093Y/5 3094Y/5 3092Y/75 3093Y/75 3094Y/75 3095Y/75 3092Y1 3093Y1 3094Y1 3092Y1/5 3093Y1/5 3094Y1/5 3092Y2/5 3093Y2/5 3094Y2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 2.5 2.5 2.5 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 NO. OF CORES WEIGHT KG/KM 2 3 4 2 3 4 5 2 3 4 2 3 4 2 3 4 46 66 70 56 68 85 104 65 77 100 80 100 130 135 150 195 Temperature limits: Fixed - -5 to +90°C. Flexing - +5 to +90°C. PVC INSULATED FLEXIBLE CORDS TYPE 309*Y (0.5MM2 TO 2.5MM2) AND ARTIC GRADE (1.5MM2 TO 4MM2) OVERALL DIAMETER (MM) 6.3 6.5 7.2 6.8 7.2 7.7 8.5 7.2 7.6 8.5 8.2 8.9 10.0 10.0 10.8 11.8 GLAND SIZE (MM) 20/16 20/16 20/16 20S 20S 20S 20S 20S 20S 20S 20S 20S 20 20S 20 20 Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow. *Bending radius: Fixed - 2 x overall diameter. Flexing - 6 x overall diameter. Should not be installed at temperatures below 0°C. ARCTIC GRADE FLEXIBLE CORDS Plain annealed flexible copper conductors, low temperature PVC insulation, low temperature PVC outer sheath. Blue or Yellow. 300/500 volts grade to BS7919 table 44 and BS6500. Flame propagation to BS EN 50265. CCC CODE 3183AG1/5 3184AG1/5 3183AG2/5 3184AG2/5 3183AG4 3183AG6 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 2.5 2.5 4 6 Temperature limits: Flexing - 40 to + 70°C *Bending radius: 6 x overall diameter. 30/0.25 30/0.25 50/0.25 50/0.25 56/0.30 76/0.30 NO. OF CORES WEIGHT KG/KM 3 4 3 4 3 3 90 130 180 220 240 315 OVERALL DIAMETER (MM) 8.20 9.55 10.15 11.30 11.40 13.2 GLAND SIZE (MM) 20S 20S 20S 20 20 20 Core identification: 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES PVC INSULATED FLEXIBLE CORDS 309*Y FLEXIBLE CABLES 68 ZERO HALOGEN FLEXIBLE CORDS (HO5 ZIZI-F) Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) outer sheath. Black or white. 300/500 volts grade (Generally to BS6500) Harmonised code HO5 ZIZI-F. Acid gas emission to BS EN 50267-2(IEC 60754-2), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332-1). CCC CODE 3182B/75 3183B/75 3184B/75 3185B/75 3182B1 3183B1 3184B1 3185B1 3182B1/5 3183B1/5 3184B1/5 3185B1/5 3182B2/5 3183B2/5 3184B2/5 3185B2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 24/0.2 24/0.2 24/0.2 24/0.2 32/0.2 32/0.2 32/0.2 32/0.2 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 NO. OF CORES WEIGHT KG/KM 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 59 70 85 110 69 82 105 130 95 120 150 180 145 180 220 265 OVERALL DIAMETER (MM) 6.8 7.2 7.7 8.5 7.2 7.6 8.5 9.1 8.2 8.9 10 11 9.9 10.8 11.3 12.8 GLAND SIZE (MM) 20/16 20/16 20/16 20S 20/16 20/16 20S 20S 20/16 20S 20S 20 20S 20S 20 20 Temperature limits: -15 to +70°c *Bending radius: Fixed 4x overall diameter Flexing 6x overall diameter Core identification: 2 core - Brown, Blue. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Should not be installed at temperatures below 0°C. LOW SMOKE ZERO HALOGEN FLEXIBLE CORDS TYPE 318*B (0.75MM2 TO 2.5MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 69 Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC CODE YY2X/75 YY3X/75 YY4X/75 YY5X/75 YY7X/75 YY12X/75 YY18X/75 YY25X/75 YY34X/75 YY50X/75 YY65X/75 YY2X1 YY3X1 YY4X1 YY5X1 YY7X1 YY12X1 YY18X1 YY25X1 YY34X1 YY41X1 YY50X1 YY65X1 YY2X1/5 YY3X1/5 YY4X1/5 YY5X1/5 YY7X1/5 YY8X1/5 YY10X1/5 YY12X1/5 YY18X1/5 YY25X1/5 YY34X1/5 YY50X1/5 YY65X1/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 Temperature limits: -5 to +70°C. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -5°C. PVC INSULATED FLEXIBLE POWER AND CONTROL CABLE TYPE “YY” (0.75MM2 TO 1.5MM2) NO. OF CORES WEIGHT KG/KM 2 3 4 5 7 12 18 25 34 50 65 2 3 4 5 7 12 18 25 34 41 50 65 2 3 4 5 7 8 10 12 18 25 34 50 65 46 52 64 77 95 155 221 305 460 578 850 55 66 82 93 121 200 318 415 575 665 815 1055 69 87 110 124 176 230 265 290 424 565 775 1095 1390 OVERALL DIAMETER (MM) 5.6 5.7 6.2 7 7.3 9.5 11.1 13.2 16.7 18.4 23.5 6 6.1 6.7 7.5 8.1 11 12.7 15.5 18.3 19 21.3 25.6 6.6 7 7.6 8.1 9.2 11.2 12.4 13.1 14.8 18 21 24.2 28.8 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20S 20 20 25 25 32 20/16 20/16 20/16 20/16 20S 20S 20 25 25 25 32 32 20/16 20/16 20/16 20S 20S 20 20 20 25 25 32 32 40 Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES TYPE YY CONTROL CABLES FLEXIBLE CABLES 70 TYPE YY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC CODE YY2X2/5 YY3X2/5 YY4X2/5 YY5X2/5 YY7X2/5 YY8X2/5 YY12X2/5 YY18X2/5 YY25X2/5 YY34X2/5 YY3X4 YY4X4 YY5X4 YY7X4 YY3X6 YY4X6 YY5X6 YY7X6 YY3X10 YY4X10 YY5X10 YY3X16 YY4X16 YY5X16 YY3X25 YY4X25 YY5X25 YY4X35 YY5X35 YY4X50 CONDUCTOR STRANDING SIZE (MM2) (MM) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 25.0 25.0 25.0 35.0 35.0 50.0 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 196/0.40 196/0.40 196/0.40 276/0.40 276/0.40 396/0.40 Temperature limits: -5 to +70°C. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -5°C. PVC INSULATED FLEXIBLE POWER AND CONTROL CABLE TYPE “YY” (2.5MM2 TO 50MM2) NO. OF CORES WEIGHT KG/KM 2 3 4 5 7 8 12 18 25 34 3 4 5 7 3 4 5 7 3 4 5 3 4 5 3 4 5 4 5 4 106 126 159 178 272 350 403 597 885 1220 201 283 293 413 273 352 415 537 466 631 720 697 767 1151 930 1150 1679 1970 2206 2700 OVERALL DIAMETER (MM) 7.8 8.1 8.9 9.7 11.1 13.5 13.8 17.5 22 25.8 10.4 10.7 12.4 14 11.5 12.8 14.6 15.2 15.3 16.5 18.6 18.4 19.9 22.4 21.5 22.5 27.9 29 31.3 34 GLAND SIZE (MM) 20/16 20S 20S 20S 20S 20 20 25 32 32 20S 20S 20 25 20 20 25 25 25 25 25 25 32 32 32 32 40 40 40 50S Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 71 Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC CODE SY2X/75 SY3X/75 SY4X/75 SY5X/75 SY7X/75 SY12X/75 SY18X/75 SY25X/75 SY34X/75 SY2X1 SY3X1 SY4X1 SY5X1 SY7X1 SY12X1 SY18X1 SY25X1 SY34X1 SY50X1 SY2X1/5 SY3X1/5 SY4X1/5 SY5X1/5 SY7X1/5 SY12X1/5 SY18X1/5 SY25X1/5 SY34X1/5 SY50X1/5 SY2X2/5 SY3X2/5 SY4X2/5 SY5X2/5 SY7X2/5 SY12X2/5 SY18X2/5 SY25X2/5 SY34X2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 Temperature limits: -5 to +70°C. *Bending radius: Static - 10 x overall diameter. Flexing - 20 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -5°C. PVC INSULATED BRAIDED FLEXIBLE CONTROL CABLE TYPE “SY” (0.75MM2 TO 2.5MM2) NO. OF CORES WEIGHT KG/KM 2 3 4 5 7 12 18 25 34 2 3 4 5 7 12 18 25 34 50 2 3 4 5 7 12 18 25 34 50 2 3 4 5 7 12 18 25 34 78 91 104 121 135 214 293 418 610 85 95 120 123 171 276 382 437 556 955 100 143 170 173 198 341 490 606 835 1046 177 190 240 247 327 502 740 1065 1126 OVERALL DIAMETER (MM) 7.1 7.6 8.3 8.9 9.5 11.9 13.2 13.7 19 7.7 8.2 9 9.2 10.1 12.9 15 17.9 20 23.7 8.2 8.6 9.3 10 10.7 13.8 16.4 19.2 21.6 23.8 9.8 9.9 10.8 11.5 13 16.9 19.8 23.2 24.3 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20S 20S 20S 20 20/16 20/16 20/16 20/16 20/16 20S 20 20 20 25 20/16 20/16 20/16 20/16 20/16 20S 20 20 25 25 20/16 20/16 20/16 20S 20S 20 20 25 25 Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES TYPE SY CONTROL CABLES FLEXIBLE CABLES 72 TYPE SY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC CODE SY3X4 SY4X4 SY5X4 SY7X4 SY3X6 SY4X6 SY5X6 SY7X6 SY3X10 SY4X10 SY5X10 SY3X16 SY4X16 SY5X16 SY4X25 SY5X25 SY4X35 SY5X35 SY4X50 SY4X70 SY4X95 CONDUCTOR STRANDING SIZE (MM2) (MM) 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 25.0 25.0 35.0 35.0 50.0 70.0 95.0 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 196/0.40 196/0.40 276/0.40 276/0.40 396/0.40 356/0.50 485/0.50 NO. OF CORES WEIGHT KG/KM 3 4 5 7 3 4 5 7 3 4 5 3 4 5 4 5 4 5 4 4 4 323 354 392 486 343 458 572 640 563 776 855 813 900 1258 1597 2007 2046 2524 2888 4015 5176 OVERALL DIAMETER (MM) 12.2 13.4 15 16 13.4 14.6 16.7 18 17.3 19.1 21 20.5 22.4 25.2 28.2 31.2 31.3 34.3 37 41.2 47.8 GLAND SIZE (MM) 20S 20S 20 20 20S 20S 20 20 20 20 25 25 25 25 32 32 40 40 40 50S 50 Temperature limits: -5 to +70°C. *Bending radius: Static - 10 x overall diameter. Flexing - 20 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -5°C. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. PVC INSULATED BRAIDED FLEXIBLE CONTROL CABLE TYPE “SY” (4MM2 TO 95MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 73 Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned copper wire braid screen, PVC outer sheath. Grey. 300/500 volts grade generally to BS6500 and VDE 0250. CCC CODE CY2X/5 CY3X/5 CY4X/5 CY5X/5 CY7X/5 CY2X/75 CY3X/75 CY4X/75 CY5X/75 CY7X/75 CY12X/75 CY18X/75 CY25X/75 CY2X1 CY3X1 CY4X1 CY5X1 CY7X1 CY12X1 CY18X1 CY25X1 CY34X1 CY2X1/5 CY3X1/5 CY4X1/5 CY5X1/5 CY7X1/5 CY12X1/5 CY18X1/5 CY25X1/5 CY34X1/5 CY42X1/5 CY2X2/5 CY3X2/5 CY4X2/5 CY5X2/5 CY7X2/5 CY12X2/5 CY2X4 CY3X4 CY4X4 CY5X4 CY4X6 CY4X10 CY4X16 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 6.0 10.0 16.0 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 80/0.40 126/0.40 Temperature limits: Static - -20 to +80°C. Flexing - -5 to +70°C. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. PVC INSULATED BRAID SCREENED FLEXIBLE POWER AND CONTROL CABLE TYPE “CY” (0.75MM2 TO 16MM2) Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -5°C. NO. OF CORES WEIGHT KG/KM 2 3 4 5 7 2 3 4 5 7 12 18 25 2 3 4 5 7 12 18 25 34 2 3 4 5 7 12 18 25 34 42 2 3 4 5 7 12 2 3 4 5 4 4 4 41 50 66 79 102 43 52 68 80 103 161 238 316 53 64 84 100 125 209 308 420 650 61 78 104 128 159 281 396 534 720 1015 102 117 168 199 252 500 165 186 239 301 327 553 846 OVERALL DIAMETER (MM) 5.0 5.2 6.2 7.0 7.2 5.5 5.8 6.5 7.1 7.6 9.9 11.7 13.9 6.3 6.4 7.2 7.8 8.5 11.3 13.3 16.23 19.5 6.5 6.9 7.7 8.6 9.2 12.7 14.7 17.49 19.89 23.8 8 8.4 9.19 10.3 11.2 16.8 10.5 10.3 11.8 13 12.9 17.2 21 GLAND SIZE (MM) BRASS A2 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20S 20 20 20/16 20/16 20/16 20/16 20/16 20S 20 25 25 20/16 20/16 20/16 20S 20 25 25 25 32 25 20/16 20/16 20S 20S 20S 25 20S 20S 20S 20S 20S 25 32 Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow o(ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES TYPE CY CONTROL CABLES FLEXIBLE CABLES 74 TYPE YY CONTROL CABLES LSZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC CODE YY2X/75LSF YY3X/75LSF YY4X/75LSF YY5X/75LSF YY2X1LSF YY3X1LSF YY4X1LSF YY5X1LSF YY2X1/5LSF YY3X1/5LSF YY4X1/5LSF YY5X1/5LSF YY7X1/5LSF YY12X1/5LSF YY18X1/5LSF YY25X1/5LSF YY34X1/5LSF YY2X2/5LSF YY3X2/5LSF YY4X2/5LSF YY5X2/5LSF YY3X4LSF YY4X4LSF YY5X4LSF YY3X6LSF YY4X6LSF YY5X6LSF YY3X10LSF YY4X10LSF YY5X10LSF YY3X16LSF YY4X16LSF YY3X25LSF CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 25.0 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.3 56/0.3 84/0.30 84/0.3 84/0.30 80/0.40 80/0.4 80/0.40 126/0.4 126/0.4 196/0.40 NO. OF CORES WEIGHT KG/KM 2 3 4 5 2 3 4 5 2 3 4 5 7 12 18 25 34 2 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 46 52 64 77 55 66 82 93 69 87 110 124 176 290 424 565 775 106 126 159 178 201 283 293 273 352 415 466 631 720 697 767 930 Temperature limits: -5 to +70°C *Bending radius: OVERALL DIAMETER (MM) 5.6 5.7 6.2 7 6 6.1 6.7 7.5 6.6 7 7.6 8.1 9.2 13.1 14.8 18 21 7.8 8.1 8.9 9.7 10.4 10.7 12.4 11.5 12.8 14.6 15.3 16.5 18.6 18.4 19.9 21.5 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 25 32 20/16 20S 20S 20S 20S 20S 20 20 20 25 25 25 25 25 32 32 Core identification: 2 Core - Black with white numbers 3 Core and above Black with white numbers plus Green/Yellow Should not be installed at temperatures below -5°C. Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter TYPE CY CONTROL CABLES LSZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen (LSZH) outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC CODE CY2X/75LSF CY3X/75LSF CY4X/75LSF CY5X/75LSF CY2X1/5LSF CY3X1/5LSF CY4X1/5LSF CY5X1/5LSF LSZH SHEATHED POWER AND CONTROL CABLE TYPE YY (0.75MM2 TO 25MM2) AND TYPE CY (0.75MM2 TO 1.5MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 30/0.25 30/0.25 30/0.25 30/0.25 Temperature limits: -5 to 70°C *Bending radius: Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter Core identification: 2 Core - Black with White numbers 3 Core and above Black with White numbers plus Green/Yellow Should not be installed at temperatures below -5°C. NO. OF CORES WEIGHT KG/KM 2 3 4 5 2 3 4 5 43 52 68 80 61 78 104 128 OVERALL DIAMETER (MM) 5.5 5.8 6.5 7.1 6.5 6.9 7.7 8.6 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow (ccc standard stock) as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 75 Plain annealed stranded circular copper conductors, circular high temperature PVC outer sheath. UL & CSA approved also to BS6231. 600/1000 volts grade. Flame propagation to BS EN 50265 and IEC 60332-1. CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM TRI0/5 TRI/75 TRI1 TRI1/5 TRI2/5 TRI4 TRI6 TRI10 TRI16 TRI25 TRI35 TRI50 TRI70 TRI95 TRI120 BI150 BI185 BI240 BI300 BI400 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150 185 240 300 400 16/0.20 24/0.20 32/0.20 30/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1525/0.50 2013/0.50 12 15 18 23 34 50 71 123 207 303 412 607 837 1079 1280 1619 1948 2518 3112 4051 OVERALL DIAMETER (MM) 2.7 2.9 3.1 3.3 3.7 4.3 4.9 6.3 9.0 10.4 11.9 14.7 16.8 18.8 19.9 22.9 24.1 28.6 32.2 36 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 25 25 32 32 32 40 50S 50 Temperature limits: -30 to +105°C. Should not be installed at temperatures below 0°C. Standard colours available: 0.5mm2 - 2.5mm2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White, Orange, Pink, Violet. 4.0mm2 - 16mm2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White. 25.0mm2 - 120mm2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow. 150mm2 - Black, Green/Yellow. 185mm2 - 400mm2 - Black. TRI-RATED SWITCHGEAR AND CONTROL PANEL WIRE (0.5MM2 TO 400MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. FLEXIBLE CABLES TRI-RATED EQUIPMENT WIRES FLEXIBLE CABLES 76 2491B/6701B LSZH FLEXIBLE SINGLE CORES Flexible plain annealed copper conductor, low smoke zero halogen (LSZH) outer sheath to BS7211. 0.75mm/1.0mm rated at 300/500 volts grade, harmonised code HO5Z-K. 1.5mm to 240mm rated at 450/750 volts grade, harmonised code HO7Z-K. Fire resistant to BS EN 50266-1:2001 (formerly BS4066:PT1). CCC CODE 2491B/75 2491B1 2491B1/5 2491B2/5 2491B4 2491B6 6701B10 6701B16 6701B25 6701B35 6701B50 6701B70 6701B95 6701B120 6701B150 6701B185 6701B240 LOW SMOKE ZERO HALOGEN SHEATHED FLEXIBLE CABLE (1.5MM2 TO 240MM2) PVC INSULATED PVC SHEATHED FLEXIBLE CABLE (6MM2 TO 400MM2) CONDUCTOR 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 STRANDING SIZE (MM) 24/0.20 32/0.20 30/0.25 50/0.25 56/0.25 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 NO. OF CORES 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Temperature limits: - 15 to + 90°C *Bending radius: up to 35mm2 - 3 x Overall Diameter 50mm2 and above - 4 x Overall Diameter WEIGHT (KG/KM) 12 14 20 30 45 65 110 160 250 340 480 670 890 1140 1410 1710 2270 OVERALL DIAMETER 2.12 2.48 2.98 3.63 4.23 4.83 6.10 7.10 8.70 9.90 11.60 13.30 15.20 17.00 18.90 21.00 23.90 Standard colours available: 1.5mm to 6mm - Black, Blue, Brown, Grey, Orange, White, Red, Yellow, Green/Yellow. 10mm2 - 240mm2 - Black, Blue, Brown, Grey. SINGLE CORE PVC FLEXIBLE MAINS CABLES Plain annealed flexible copper conductor, PVC insulated PVC sheathed, 450/750 volts, generally to BS6004 & IEC60502. Flame propogation to BS4066 PT1 & IEC332 PT1. CCC CODE 6381Y6 6381Y10 6381Y16 6381Y25 6381Y35 6381Y50 6381Y70 6381Y95 6381Y120 6381Y150 6381Y185 6381Y240 6381Y300 6381Y400 CONDUCTOR STRANDING SIZE (MM2) (MM) 6.0 10.00 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1525/0.50 2013/0.50 Temperature limits: -15 to +70°C. *Bending radius: Up to 50mm 3 x overall diameter. Over 70mm 5 x overall diameter. NO. OF CORES WEIGHT KG/KM 1 1 1 1 1 1 1 1 1 1 1 1 1 1 105 151 208 303 401 560 748 990 1233 1528 1857 2419 3032 3937 OVERALL DIAMETER (MM) 7.7 8.8 9.9 11.4 12.7 14.6 16.1 18.6 20.2 22.5 25.1 28.3 31.2 35.4 GLAND SIZE (MM) 20/16 20S 20S 20 20 25 25 25 32 32 32 40 40 50S Standard core colours available: Black, grey, blue, brown, green/yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 77 Electroltic annealed tinned flexible copper conductor, halogen free thermosetting rubber insulation, type EI6 according to EN 50363-1 and table 4 of the TUV standard, halogen free thermosetting rubber outer sheath, type EM8 according to EN 50363-1 and table 4 of the TUV standard. Black. CCC CONDUCTOR CODE SOLAR1X1/5BK 1.5 SOLAR1X2/5BK 2.5 SOLAR1X4BK 4.0 SOLAR1X6BK 6.0 SOLAR1X10BK 10 SOLAR1X16BK 16 SOLAR1X25BK 25 SOLAR1X35BK 35 STRANDING SIZE (MM) 29/0.25 48/0.25 48/0.3 72/0.3 126/0.3 116/0.4 180/0.4 260/0.4 NO. OF CORES 1 1 1 1 1 1 1 1 WEIGHT (KG/KM) 40 49 66 86 132 188 294 390 OVERALL DIAMETER 4.90 5.35 6.00 6.55 7.60 8.60 10.80 11.90 Characteristics. Nominal voltage: AC: 0,6/1 kV; DC: 1,8 kV Ambient temperature range: -40 °C to + 90 ºC. Maximum conductor temperature: 120 ºC. Maximum short-circuit temperature: 250 °C (maximum 5 s). *Minimum bending radius (fixed): 5 x cable Ø. No flame propagation: EN 60332-1-2 / IEC 60332-1-2. No fire propagation: EN 60332-3 / IEC 60332-3. Halogen free: according to EN 50267 / IEC 60754 HCl content < 0,5%. pH > 4,3; conductivity < 10 !S/mm. Smoke density: light transmittance > 60% (according to EN 61034 / IEC 61034). SOLAR ENERGY CABLES Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES SOLAR ENERGY CABLES FLEXIBLE CABLES 78 FLEXIBLE MAINS AND CONTROL CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500. Black or White. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised code H07BN4-F. CCC CODE 3182TQ/75 3183TQ/75 3184TQ/75 3182TQ1 3183TQ1 3184TQ1 3181TQ1/5 3182TQ1/5 3183TQ1/5 3184TQ1/5 3185TQ1/5 3186TQ1/5 3187TQ1/5 3180/12TQ1/5 3180/16TQ1/5 3180/20TQ1/5 3180/27TQ1/5 3180/37TQ1/5 3181TQ2/5 3182TQ2/5 3183TQ2/5 3184TQ2/5 3185TQ2/5 3187TQ2/5 3180/12TQ2/5 3180/16TQ2/5 3180/20TQ2/5 3180/27TQ2/5 3180/37TQ2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 NO. OF CORES WEIGHT KG/KM 2 3 4 2 3 4 1 2 3 4 5 6 7 12 16 20 27 37 1 2 3 4 5 7 12 16 20 27 37 58 72 86 80 90 110 38 115 135 170 200 335 366 410 570 710 920 1260 41 160 195 245 300 424 600 780 1050 1390 1720 MEAN OVERALL DIAMETER (MM) LOWER LIMIT UPPER LIMIT 5.7 7.4 6.2 8.1 6.8 8.8 6.1 8.0 6.5 8.5 7.1 9.3 5.7 7.1 7.6 9.8 8.0 10.4 9.0 11.6 11.2 14.4 13.4 17.2 14.6 18.2 17.6 22.4 19.8 24.3 21.4 26.7 25.3 30.0 29.0 34.2 6.3 7.9 9.0 11.6 9.6 12.4 10.7 13.8 13.3 17.0 17.2 21.0 20.6 26.2 23.8 28.4 26.4 31.2 30.1 35.4 35.0 40.9 Temperature limits: -25 to +90°C. *Bending radius: Fixed - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -25°C. EPR INSULATED HOFR SHEATHED FLEXIBLE POWER AND CONTROL CABLE (0.75MM2 TO 2.5MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 79 Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised code H07BN4-F. CCC CODE 6381TQ4 6382TQ4 6383TQ4 6384TQ4 6385TQ4 6387TQ4 6380/12TQ4 6381TQ6 6382TQ6 6383TQ6 6384TQ6 6385TQ6 6387TQ6 6388TQ6 6381TQ10 6382TQ10 6383TQ10 6384TQ10 6385TQ10 6381TQ16 6382TQ16 6383TQ16 6384TQ16 6385TQ16 CONDUCTOR STRANDING SIZE (MM2) (MM) 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6 6 6 6 6 6 6 10 10 10 10 10 16 16 16 16 16 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 126/0.40 126/0.40 NO. OF CORES WEIGHT KG/KM 1 2 3 4 5 7 12 1 2 3 4 5 7 8 1 2 3 4 5 1 2 3 4 5 105 275 335 420 515 773 1183 130 370 450 565 690 904 1040 200 690 835 1020 1240 275 910 1120 1380 1695 MEAN OVERALL DIAMETER (MM) LOWER LIMIT UPPER LIMIT 7.2 9.0 11.8 15.1 12.7 16.2 14.0 17.9 15.6 19.9 19.8 24.4 24.4 30.9 7.9 9.8 13.1 16.8 14.1 18.0 15.7 20.0 17.5 22.9 21.6 26.9 25.2 29.6 9.5 11.9 17.7 22.6 19.1 24.2 20.9 26.5 22.9 29.1 10.8 13.4 20.2 25.7 21.8 27.6 23.8 30.1 26.4 33.3 Temperature limits: -25 to +90°C. *Bending radius: Fixed - 6 x overall diameter. Flexing - 7 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -25°C. EPR INSULATED HEAVY DUTY HOFR SHEATHED FLEXIBLE MAINS CABLE (4MM2 TO 16MM2 ) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES FLEXIBLE MAINS CABLES EPR,CSP FLEXIBLE CABLES 80 FLEXIBLE MAINS CABLES EPR,CSP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised code H07BN4-F. CCC CODE 6381TQ25 6382TQ25 6383TQ25 6384TQ25 6385TQ25 6381TQ35 6382TQ35 6383TQ35 6384TQ35 6385TQ35 6381TQ50 6383TQ50 6384TQ50 6385TQ50 6381TQ70 6383TQ70 6384TQ70 6385TQ70 6381TQ95 6383TQ95 6384TQ95 6385TQ95 6381TQ120 6383TQ120 6384TQ120 6385TQ120 6381TQ150 6383TQ150 6384TQ150 6381TQ185 6383TQ185 6384TQ185 6381TQ240 6383TQ240 6384TQ240 6381TQ300 6383TQ300 6384TQ300 6381TQ400 6381TQ500 6381TQ630 CONDUCTOR STRANDING SIZE (MM2) (MM) 25 25 25 25 25 35 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 500 630 196/0.40 196/0.40 196/0.40 196/0.40 196/0.40 276/0.40 276/0.40 276/0.40 276/0.40 276/0.40 396/0.40 396/0.40 396/0.40 396/0.40 360/0.50 360/0.50 360/0.50 360/0.50 475/0.50 475/0.50 475/0.50 475/0.50 608/0.50 608/0.50 608/0.50 608/0.50 756/0.50 756/0.50 756/0.50 925/0.50 925/0.50 925/0.50 1221/0.50 1221/0.50 1221/0.50 1525/0.50 1525/0.50 1525/0.50 2013/0.50 1769/0.60 2257/0.60 Temperature limits: -25 to +90°C. *Bending radius: Fixed - 5 x overall diameter. Flexing - 7 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. EPR INSULATED HOFR SHEATHED POWER AND CONTROL CABLE (25MM2 TO 630MM2) NO. OF CORES WEIGHT KG/KM 1 2 3 4 5 1 2 3 4 5 1 3 4 5 1 3 4 5 1 3 4 5 1 3 4 5 1 3 4 1 3 4 1 3 4 1 3 4 1 1 1 400 1290 1600 2140 2470 520 1308 2080 2610 3187 730 2890 3650 4450 980 3850 4880 5938 1270 4970 6390 7924 1570 6350 7750 7542 1960 7700 9780 2380 9350 11900 3100 12000 15330 3790 14910 19030 4880 6070 7460 MEAN OVERALL DIAMETER (MM) LOWER LIMIT UPPER LIMIT 12.7 15.8 24.3 30.7 26.1 33.0 28.9 36.6 32.0 40.4 14.3 17.9 26.4 31.5 29.3 37.1 32.5 41.1 34.0 43.0 16.5 20.6 34.1 42.9 37.7 47.5 39.03 49.18 18.6 23.3 38.4 48.3 42.7 54.0 48.5 55.0 20.8 26.0 43.3 54.0 48.4 61.0 54.0 64.5 22.8 28.6 47.4 60.0 53.0 66.0 57.9 58.5 25.2 31.4 52.0 66.0 58.0 73.0 27.6 34.4 57.0 72.0 64.0 80.0 30.6 38.3 65.0 82.0 72.0 91.0 33.5 41.9 72.0 90.0 80.0 101.0 37.4 46.8 41.3 52.0 45.5 56.5 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -25°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 81 Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized code type HO7RN-F. Flame propagation to EN 60332-1-2. CCC CODE 3182P1 3183P1 3184P1 3182P1/5 3183P1/5 3184P1/5 3185P1/5 3187P1/5 3180/12P1/5 3182P2/5 3183P2/5 3184P2/5 3185P2/5 3187P2/5 3180/12P2/5 3182P4 3183P4 3184P4 3185P4 6382P6 6383P6 6384P6 6385P6 6381P10 6382P10 6383P10 6384P10 6385P10 6381P16 6382P16 6383P16 6384P16 6385P16 6381P25 6382P25 6383P25 6384P25 6385P25 6381P35 6383P35 6384P35 6385P35 6381P50 6383P50 6384P50 6385P50 CONDUCTOR STRANDING (MM) SIZE (MM2) 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 10 10 10 10 10 16 16 16 16 16 25 25 25 25 25 35 35 35 35 50 50 50 50 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 126/0.40 126/0.40 196/0.40 196/0.40 196/0.40 196/0.40 196/0.40 276/0.40 276/0.40 276/0.40 276/0.40 396/0.40 396/0.40 396/0.40 396/0.40 Temperature limits: -25 to +60°C. Can be supplied suitable for up to 85°C upon special request. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. NO. OF CORES WEIGHT KG/KM 2 3 4 2 3 4 5 7 12 2 3 4 5 7 12 2 3 4 5 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 3 4 5 1 3 4 5 95 115 140 132 165 200 240 385 520 193 235 290 345 520 810 275 320 395 485 350 495 610 760 230 640 880 1060 1300 320 850 1090 1345 1680 450 1210 1394 1995 2470 605 1850 2645 2930 825 2890 3635 4450 MEAN OVERALL DIAMETER (MM) LOWER LIMIT UPPER LIMIT 6.1 8.0 6.5 8.5 7.1 9.3 7.6 9.8 8.0 10.4 9.0 11.6 11.2 14.4 14.6 18.2 17.6 22.4 9.0 11.6 9.6 12.4 10.7 13.8 13.3 17.0 17.2 21.0 20.6 26.2 11.8 15.1 12.7 16.2 14.0 17.9 15.6 19.9 13.1 16.8 14.1 18.0 15.7 20.0 17.5 22.9 9.5 11.9 17.7 22.6 19.1 24.2 20.9 26.5 22.9 29.1 10.8 13.4 20.2 25.7 21.8 27.6 23.8 30.1 26.4 33.3 12.7 15.8 24.3 30.7 26.1 33.0 28.9 36.6 32.0 40.4 14.3 17.9 29.3 37.1 32.5 41.1 34.0 43.0 16.5 20.6 34.1 42.9 37.7 47.5 39.03 49.18 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below 0°C. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. RUBBER INSULATED NEOPRENE SHEATHED FLEXIBLE POWER CABLE (1MM2 TO 50MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F FLEXIBLE CABLES 82 FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized code type HO7RN-F. Flame propagation to EN 60332-1-2. CCC CODE 6381P70 6383P70 6384P70 6385P70 6381P95 6383P95 6384P95 6385P95 6381P120 6383P120 6384P120 6381P150 6383P150 6384P150 6381P185 6383P185 6384P185 6381P240 6381P300 6381P400 6383P240 6384P240 6381P500 6381P630 CONDUCTOR STRANDING SIZE (MM2) (MM) 70 70 70 70 95 95 95 95 120 120 120 150 150 150 185 185 185 240 300 400 240 240 500 630 360/0.50 360/0.50 360/0.50 360/0.50 475/0.50 475/0.50 475/0.50 475/0.50 608/0.50 608/0.50 608/0.50 756/0.50 756/0.50 756/0.50 925/0.50 925/0.50 925/0.50 1221/0.50 1525/0.50 2257/0.50 1221/0.50 1221/0.50 1769/0.60 2257/0.60 Temperature limits: -25 to +60°C. Can be supplied suitable for up to 85°C upon special request. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. RUBBER INSULATED NEOPRENE SHEATHED FLEXIBLE POWER CABLE (70MM2 TO 630MM2) NO. OF CORES WEIGHT KG/KM 1 3 4 5 1 3 4 5 1 3 4 1 3 4 1 3 4 1 1 1 3 4 1 1 1090 3850 4830 5938 1405 4185 6320 6695 1745 5051 6453 1824 6267 8031 2202 7661 9830 2847 3495 4880 9692 12444 5301 7460 MEAN OVERALL DIAMETER (MM) LOWER LIMIT UPPER LIMIT 18.6 23.3 38.4 48.3 42.7 54.0 48.5 55.0 20.8 26.0 43.3 50 48.5 61.0 54.0 64.5 22.8 28.6 47.4 60.0 53.0 66.0 25.2 31.4 52.0 66.0 58.0 73.0 27.6 34.4 57.0 72.0 64.0 80.0 30.6 38.3 33.5 41.9 45.5 56.5 65.0 82.0 72.0 91.0 41.3 52.0 45.5 56.5 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 83 Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, tough rubber sheath. Black. 300/500 volts grade to BS6500 and BS7919. CCC CODE 3182/75 3183/75 3184/75 31821 31831 31841 31821/5 31831/5 31841/5 31851/5 31822/5 31832/5 31842/5 31852/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 24/0.20 24/0.20 24/0.20 30/0.20 30/0.20 30/0.20 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 NO. OF CORES WEIGHT KG/KM 2 3 4 2 3 4 2 3 4 5 2 3 4 5 63 78 94 77 90 110 115 135 170 195 165 195 245 290 Temperature limits: +60°C. *Bending radius: EPR INSULATED BRAIDED SCREEN FLEXIBLE MAINS AND CONTROL CABLE (1.0MM2 TO 16MM2) GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20S 20S 20S 20S 20 20 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 x overall diameter. EPR INSULATED TOUGH RUBBER SHEATH (0.75MM2 TO 2.5MM2) OVERALL DIAMETER (MM) 6.6 7.2 7.8 7.1 7.5 8.2 8.7 9.2 9.8 10.3 10.3 11.0 11.9 12.3 Core identification: 2 core - Blue, Brown. BRAIDED TOUGH RUBBER SHEATH FLEXIBLE CORDS Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, chlorosulphonated polyethylene bedding (CSP), tinned copper wire braid screen, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500/75 and 450/750 Volts grade to BS6007/75 (where applicable). Black. Flame propogation to BS 4066 PT1 and IEC 332 PT1. Heat and oil resistant and flame retardant (HOFR). CCC CODE 3802TQ1 3803TQ1 3804TQ1 3802TQ1/5 3803TQ1/5 3804TQ1/5 3802TQ2/5 3803TQ2/5 3804TQ2/5 3803TQ4 3804TQ4 6803TQ6 6804TQ6 6803TQ10 6804TQ10 6803TQ16 6804TQ16 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.0 1.0 1.0 1.5 1.5 1.5 2.5 2.5 2.5 4.0 4.0 6.0 6.0 10.0 10.0 16.0 16.0 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 84/0.30 84/0.30 90/0.40 90/0.40 126/0.40 126/0.40 Temperature limits: -25 to +90°C. *Bending radius: 8 x overall diameter. NO. OF CORES WEIGHT KG/KM 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 3 4 170 200 230 225 270 320 300 350 420 715 865 973 1166 1592 1878 1992 2452 OVERALL DIAMETER (MM) 11.1 11.4 12.1 12.3 13.1 14.2 14.8 15.6 17.0 21.3 23.6 24.8 27.1 30.7 33.3 33.8 37.2 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20S 20S 20S 20 20 25 25 25 32 32 40 40 40 4 core - Grey, Black, Brown, Blue, Green/Yellow. Should not be installed at temperatures below 0°C. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES TOUGH RUBBER SHEATH FLEXIBLE CORDS FLEXIBLE CABLES 84 COIL END LEAD FLEXIBLE MAINS CABLES Flexible tinned annealed copper conductors composite ethylene propylene rubber chlorosulphonated polyethylene (EPR-CSP) insulation to BS6195/69 Type 4. A. 300/500 volts grade C. 600/1000 volts grade D. 1900/3300 volts grade E. 3800/6600 volts grade F. 6350/11000 volts grade CONDUCTOR CCC CODE SIZE (MM2) STRANDING (MM2) TYPE 4 1/5 TYPE 4 2/5 TYPE 4 4 TYPE 4 6 TYPE 4 10 TYPE 4 16 TYPE 4 25 TYPE 4 35 TYPE 4 50 TYPE 4 70 TYPE 4 95 TYPE 4 120 TYPE 4 150 TYPE 4 185 TYPE 4 240 TYPE 4 300 TYPE 4 400 TYPE 4 500 0.5 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 16/0.20 24/0.20 32/0.20 30/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1525/0.50 2013/0.50 3679/0.40 CCC CODE TYPE 4 1/5 TYPE 4 2/5 TYPE 4 4 TYPE 4 6 TYPE 4 10 TYPE 4 16 TYPE 4 25 TYPE 4 35 TYPE 4 50 TYPE 4 70 TYPE 4 95 TYPE 4 120 TYPE 4 150 TYPE 4 185 TYPE 4 240 TYPE 4 300 TYPE 4 400 TYPE 4 500 EPR INSULATED FLEXIBLE COIL LEAD (0.5MM2 TO 400MM2) RADIAL THICKNESS OF INSULATION VOLTAGE CATEGORY MAX APPROX. A C D E F DIA. OF DIA. OF (MM) (MM) (MM) (MM) (MM) WIRES COND. (MM) (MM) 0.21 0.93 0.8 1.4 0.21 1.14 0.8 1.4 0.21 1.32 0.8 1.4 0.26 1.60 0.8 1.4 0.26 2.00 0.9 1.4 2.8 0.31 2.6 1.0 1.4 0.31 3.6 1.0 1.5 0.41 4.6 1.2 1.5 0.41 5.7 1.5 2.8 5.0 7.6 0.41 7.1 1.6 2.8 5.0 7.6 0.41 8.5 1.6 2.8 5.0 7.6 0.41 10.3 1.7 2.8 5.0 7.6 0.51 12.4 1.8 2.8 5.0 7.6 0.51 14.5 2.0 3.0 5.0 7.6 0.51 16.0 2.2 3.0 5.0 7.6 0.51 18.0 2.3 3.0 5.0 7.6 0.51 20.0 2.4 3.0 5.0 7.6 0.51 23.0 2.4 3.0 5.0 7.6 0.51 26.0 2.6 3.0 0.51 30.0 2.8 3.0 0.61 29.0 3.0 - MINIMUM OVERALL DIAMETER WEIGHT VOLTAGE CATEGORY VOLTAGE CATEGORY A C D E F A C D E (MM) (MM) (MM) (MM) (MM) KG/KM KG/KM KG/KM KG/KM 3.3 4.5 12 17 3.5 4.7 16 21 3.7 4.9 19 24 4.0 5.2 25 30 4.6 5.6 8.5 37 41 76 5.4 6.3 57 66 6.5 7.5 80 93 7.9 8.5 130 136 9.6 12.4 17.2 22.9 206 255 384 11.4 13.8 18.6 24.1 300 351 495 12.8 15.2 20.0 25.5 406 458 613 14.8 17.1 21.1 27.3 573 616 796 17.2 19.2 24.2 29.4 793 820 1020 19.7 22.0 26.3 31.5 1028 1097 1287 21.9 23.5 27.8 33.3 1285 1340 1542 24.1 25.5 29.8 35.3 1562 1635 1853 26.3 27.5 32.1 37.3 1914 1973 2225 29.3 30.5 35.1 40.3 2431 2504 2782 33.0 33.8 3024 3098 37.4 37.8 3948 4045 34.8 4920 - Temperature limits: -20 to +90°C. *Bending radius: F KG/KM 566 680 810 997 1237 1520 1804 2131 2503 3081 - Should not be installed at temperatures below -25°C. 6 x overall diameter. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 85 Tinned annealed flexible circular copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Orange. Ref 0361TQ. To BS638 Part 4. Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). CCC CODE CONDUCTOR SIZE (MM2) STRANDING (MM) WEIGHT KG/KM 0361TQ16OR 0361TQ25OR 0361TQ35OR 0361TQ50OR 0361TQ70OR 0361TQ95OR 0361TQ120OR 0361TQ185OR 16 25 35 50 70 95 120 185 513/0.20 783/0.20 1107/0.20 1566/0.20 2214/0.20 2997/0.20 608/0.50 925/0.50 235 330 440 610 840 1120 1410 2100 OUTSIDE DIAMETER (MM) 11.5 13.0 14.5 17.0 19.5 22.0 24.0 29.0 GLAND SIZE (MM) 20S 20 25 25 32 32 32 40 Temperature limits: -20 to +85°C. *Bending radius: 8 x overall diameter. EPR INSULATED FLEXIBLE WELDING CABLE TYPE 0361TQ (16MM2 TO 185MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES WELDING CABLES 0361TQ FLEXIBLE CABLES 86 RUBBER FLATFORM CABLES Flexible plain copper conductors, thermoplastic rubber insulated (TPR) thermoplastic outer sheath (TPR). Black. 600/1000 volts grade. CCC CODE FLAT4X1/5R FLAT12X1/5R FLAT4X2/5R FLAT7X2/5R FLAT12X2/5R FLAT4X4R FLAT4X6R FLAT4X10R FLAT4X16R FLAT4X25R FLAT4X35R FLAT4X50R FLAT4X70R CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 2.5 2.5 2.5 4 6 10 16 25 35 50 70 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 NO. OF CORES WEIGHT KG/KM 4 12 4 7 12 4 4 4 4 4 4 4 4 110 320 170 300 490 250 330 550 800 1350 1800 2400 3250 OVERALL MAX CURRENT DIMENSIONS RATINGS (MM) (AMPS) 16X5 22 29X5 12 19X6 30 33X7 20 51X6 20 21X7 40 24X7 52 29X9 70 35X10 95 46X14 127 51X15 157 56X17 190 63X18 242 Temperature limits: -35 to +85°C. *Bending radius: 7 and 12 core - Black cores with White numbers and one Green/Yellow. 10 x overall diameter. Should not be installed at temperatures below 0°C. Core identification: 4 core - Black, Grey, Brown, Green/Yellow. PVC FLATFORM CABLES Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black. 450/750 volts grade type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6. CCC CODE FLAT4X1/5V FLAT12X1/5V FLAT4X2/5V FLAT12X2/5V FLAT4X4V FLAT4X6V FLAT4X10V FLAT4X16V FLAT4X25V FLAT4X35V FLAT4X50V FLAT4X70V FLAT4X95V RUBBER INSULATED FLAT CABLE (1.5MM2 TO 70MM2) AND PVC INSULATED FLAT CABLE (1.5MM2 TO 95MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 2.5 2.5 4 6 10 16 25 35 50 70 95 30/0.25 30/0.25 50/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 Temperature limits: -25 to +70°C. *Bending radius: 10 x overall diameter. NO. OF CORES WEIGHT KG/KM 4 12 4 12 4 4 4 4 4 4 4 4 4 150 420 210 620 300 385 620 990 1550 2030 2650 3650 4550 OVERALL MAX CURRENT DIMENSIONS RATINGS (MM) (AMPS) 15X5 20 41X5 11 19X6 27 51X6 16 21X7 36 23X7 48 29X9 63 37X11 85 46X14 112 51X15 138 56X17 168 63X18 213 73X21 258 12 core - Black cores with white numbers and one Green/Yellow. Should not be installed at temperatures below 0°C. Core identification: 4 core - Black, Grey, Brown, Green/Yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 87 Flexible tinned annealed copper conductors, silicone insulated, silicone outer sheath. 300/500 volts grade to VDE 0250 PT816. CCC CODE BIHF2X/75 BIHF3X/75 BIHF4X/75 BIHF5X/75 BIHF7X/75 BIHF2X1 BIHF3X1 BIHF4X1 BIHF5X1 BIHF7X1 BIHF2X1/5 BIHF3X1/5 BIHF4X1/5 BIHF5X1/5 BIHF7X1/5 BIHF2X2/5 BIHF3X2/5 BIHF4X2/5 BIHF5X2/5 BIHF7X2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 NO. OF CORES WEIGHT KG/KM 2 3 4 5 7 2 3 4 5 7 2 3 4 5 7 2 3 4 5 7 53.4 63.7 83.6 101.2 124.9 59.9 78.3 94.6 116.1 144.3 82.0 98.0 122.0 148.0 187.0 135.0 152.0 188.0 230.0 293.0 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 OVERALL DIAMETER (MM) 6.5 6.9 7.9 8.6 9.3 6.7 7.5 8.1 8.9 9.6 7.6 8.0 8.8 9.6 10.4 8.9 9.1 10.1 10.9 13.1 GLAND SIZE (MM) 20/16 20/16 20/16 20S 20S 20/16 20/16 20S 20S 20S 20/16 20/16 20S 20S 20S 20S 20S 20S 20S 20 Temperature limits: -60 to +180°C. *Bending radius: Fixed - 5 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core and above - Grey, Black, Brown, Blue, Green/Yellow 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below 0°C. SILICONE INSULATED FLEXIBLE CABLE (0.75MM2 TO 2.5MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. FLEXIBLE CABLES SILICON FLEXIBLE CABLES SIHF 89 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 90 INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation, Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. PAS5308 PART 2, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. CCC CODE PT1 PT2 7100 7101 7102 7103 7104 7105 7106 7107 7136 7137 7138 7139 7140 7141 7142 7143 7173 7174 7175 7176 7177 N/A N/A 7178 7300 7301 7302 7303 7304 7305 7306 7307 7336 7337 7338 7339 7340 7341 7342 7343 7373 7374 7375 7376 7377 N/A N/A 7378 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 NO. OF PAIRS 1 2 5 10 20 30 50 1 TRIPLE 1 2 5 10 20 30 50 1 TRIPLE 1 2 5 10 20 30 50 1 TRIPLE WEIGHT OUTSIDE KG/KM DIAMETER (MM) 60 6.00 75 6.90 190 12.10 305 16.20 518 21.30 759 25.90 1251 32.90 69 6.10 69 6.30 99 7.30 242 13.30 380 17.70 684 23.50 989 28.50 1670 36.40 83 6.80 87 7.30 145 8.70 345 15.40 575 20.60 1075 27.50 1720 33.7 2750 43.6 115 8.40 BRASS A2 GLAND 20/16 20/16 20 25 32 32 50S 20/16 20/16 20/16 20 25 32 40 50S 20/16 20/16 20S 25 32 40 50S 63S 20S PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) sheath, Blue or Black, to PAS5308 Part 1, Type 1 LSZH. CCC CODE 7246 7247 7248 7249 7250 7251 INSTRUMENTATION AND CONTROL CABLES NON-ARMOURED WITH COLLECTIVE SCREEN (0.5MM2 TO 1.5MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 0.75 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 NO. OF PAIRS WEIGHT KG/KM 1 2 5 10 20 30 69 99 242 380 684 989 OVERALL DIAMETER (MM) 6.30 7.30 13.30 17.70 23.50 28.50 BRASS A2 GLAND 20/16 20/16 20 25 32 40 Temperature limits: -20 to +65°C. *Bending radius: Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. 5 x overall diameter. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 91 PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. PAS5308 PART 2, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. CCC CODE PT1 PT2 7112 7113 7114 7115 7116 7117 7149 7150 7151 7152 7153 7154 7185 7186 7187 7188 - 7312 7313 7314 7315 7316 7317 *7349 7350 7351 7352 7353 7354 7385 7386 7387 7388 - CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 NO. OF PAIRS 2 5 10 20 30 50 2 5 10 20 30 50 2 5 10 20 30 50 WEIGHT OUTSIDE KG/KM DIAMETER (MM) 161 11.00 253 14.20 408 20.10 753 26.30 1153 31.30 1900 40.70 184 11.80 299 15.30 489 21.70 920 28.80 1445 34.50 2460 44.00 242 13.70 408 17.80 714 25.50 1337 33.40 2040 40.4 3260 52.2 BRASS A2 GLAND 20S 25 32 40 40 50 20 25 32 40 50S 63S 25 25 32 50S 50 63 PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar tape screened. Complete with 0.5mm2 drain wire, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) outer sheath, Black or Blue, generally to PAS5308 Part 1, Type 1 LSZH. CCC CODE 71149 71150 71151 71152 7253 INSTRUMENTATION AND CONTROL CABLES NON-ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREENS (0.5MM2 TO 1.5MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 NO. OF PAIRS WEIGHT KG/KM 2 5 10 20 30 184 299 489 920 1445 OVERALL DIAMETER (MM) 11.80 15.30 21.70 28.80 34.50 BRASS A2 GLAND 20 25 32 40 50S Temperature limits: -20 to +65°C. *Bending radius: Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. 5 x overall diameter. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - PAS5308 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 92 INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PAS5308 PART 2, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PT1 CCC CODE 7118 7119 7120 7121 7122 7123 7124 7125 7155 7156 7157 7158 7159 7160 7161 7162 7189 7190 7191 7192 7193 7194 7195 7196 7208 7209 7210 7211 7212 7213 PT2 7318 7319 7320 7321 7322 7323 7324 7325 7355 7356 7357 7358 7359 7360 7361 7362 7389 7390 7391 7392 7393 7394 7395 7396 7408 7409 7410 7411 7412 7413 CONDUCTOR STRANDING No. OF WEIGHT OVERALL SIZE (MM2) (MM) PAIRS KG/KM DIAMETER (MM) 0.5 16/0.20 1 242 10.8 0.5 16/0.20 2 288 11.7 0.5 16/0.20 5 535 17.3 0.5 16/0.20 10 868 22.3 0.5 16/0.20 20 1466 28.5 0.5 16/0.20 30 1944 33.3 0.5 16/0.20 50 3360 41.5 0.5 16/0.20 1 TRIPLE 259 11.0 0.75 24/0.20 1 270 11.1 0.75 24/0.20 2 330 12.3 0.75 24/0.20 5 719 19.2 0.75 24/0.20 10 1150 24.7 0.75 24/0.20 20 1704 30.7 0.75 24/0.20 30 2570 36.9 0.75 24/0.20 50 4400 46.4 0.75 24/0.20 1 TRIPLE 288 11.4 1.5 7/0.53 1 312 12.3 1.5 7/0.53 2 397 13.7 1.5 7/0.53 5 918 21.5 1.5 7/0.53 10 1466 27.8 1.5 7/0.53 20 2519 35.1 1.5 7/0.53 30 3352 41.9 1.5 7/0.53 50 5310 53.4 1.5 7/0.53 1 TRIPLE 357 12.6 2.5 7/0.67 1 395 13.1 2.5 7/0.67 2 490 15.9 2.5 7/0.67 5 1430 26.5 2.5 7/0.67 10 2235 35.1 2.5 7/0.67 20 3935 46.7 2.5 7/0.67 1 TRIPLE 407 13.7 GLAND SIZE (MM) 20/16 20S 20 25 32 32 50S 20/16 20/16 20S 20 25 32 40 50S 20S 20S 20S 25 32 40 50S 63S 20S 20S 20 20 40 50 20S CLEAT SIZE (MM) 0.5 0.5 0.7 0.9 1.2 1.4 1.8 0.5 0.5 0.5 0.8 1.0 1.2 1.6 2.0 0.5 0.5 0.6 0.9 1.1 1.4 1.8 TC9 0.5 0.6 0.6 1.1 1.4 2.0 0.6 PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, low smoke zero halogen bedding (LSZH), galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Black or Blue, generally to PAS5308 Part 1, Type 2 LSZH. CCC CODE 7255 7256 7257 7258 7259 7260 7261 7289 7290 7291 7292 7293 INSTRUMENTATION AND CONTROL CABLES ARMOURED WITH COLLECTIVE SCREEN (0.5MM2 TO 2.5MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 Temperature limits: -20 to +65°C. *Bending radius: 6 x overall diameter.. 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 24/0.2 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 NO. OF PAIRS 1 2 5 10 20 30 50 1 2 5 10 20 WEIGHT OVERALL KG/KM DIAMETER (MM) 270 10.70 330 11.90 719 18.80 1150 24.30 1704 30.30 2570 36.9 4400 46.4 312 11.90 397 13.30 918 21.10 1466 27.40 2519 35.50 GLAND SIZE (MM) 20/16 20S 20 25 32 40 50S 20S 20S 25 32 40 CLEAT SIZE (MM) 0.5 0.5 0.8 1.0 1.2 1.6 2.0 0.5 0.6 0.9 1.1 1.4 Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 93 PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PAS5308 PART 2, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. CCC CODE PT1 PT2 7130 7131 7132 7133 7134 7135 7167 7168 7169 7170 7171 7172 7201 7202 7203 7204 7205 7206 7330 7331 7332 7333 7334 7335 7367 7368 7369 7370 7371 7372 7401 7402 7403 7404 7405 7406 CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND SIZE (MM2) (MM) PAIRS KG/KM DIAMETER SIZE (MM) (MM) 0.5 16/0.20 2 460 16.8 20 0.5 16/0.20 5 730 19.90 20 0.5 16/0.20 10 1202 26.90 32 0.5 16/0.20 20 1870 34.3 40 0.5 16/0.20 30 2620 40.5 50S 0.5 16/0.20 50 4180 51.5 50 0.75 24/0..20 2 518 16.60 20 0.75 24/0.20 5 805 21.00 25 0.75 24/0.20 10 1323 28.50 32 0.75 24/0.20 20 2323 36.80 40 0.75 24/0.20 30 3312 42.90 50S 0.75 24/0.20 50 5520 54.00 63S 1.5 7/0.53 2 707 19.40 20 1.5 7/0.53 5 1185 24.40 25 1.5 7/0.53 10 1668 32.50 32 1.5 7/0.53 20 2956 41.60 50S 1.5 7/0.53 30 3650 50.8 50 1.5 7/0.53 50 5640 62.6 63 CLEAT SIZE (MM) 0.7 0.8 1.1 1.4 1.6 TC9 0.7 0.9 1.2 1.6 1.8 TC9 0.8 1.0 1.4 1.8 TC9 TC10 PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Blue or Black, generally to PAS5308 Part 1, Type 2 LSZH. CCC CODE 7267 7268 7269 7270 7298 7299 7297 7296 INSTRUMENTATION AND CONTROL CABLES ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREEN (0.5MM2 TO 1.5MM2) CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 7/0.53 7/0.53 7/0.53 7/0.53 NO. OF PAIRS 2 5 10 20 2 5 10 20 WEIGHT OVERALL KG/KM DIAMETER (MM) 518 16.60 805 21.00 1323 28.50 2323 36.80 707 19.40 1185 24.40 1668 32.50 2956 41.60 GLAND SIZE (MM) 20 25 32 40 20 25 32 50S CLEAT SIZE (MM) 0.7 0.9 1.2 1.6 0.8 1.0 1.4 1.8 Temperature limits: -20 to +65°C. *Bending radius: Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. 6 x overall diameter. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - PAS5308 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 94 INSTRUMENTATION AND CONTROL CABLES - PAS5308 PAS5308 PART 1, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. PAS5308 PART 2, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. CCC CODE PT1 PT2 7821 7822 7823 7824 7825 7826 7827 7971 7972 7973 7974 7975 7976 7977 7851 7852 7853 7854 7855 7856 7857 7921 7922 7923 7924 7925 7926 7927 7951 7952 7953 7954 7955 7956 7957 CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND SIZE (MM2) (MM) PAIRS KG/KM DIAMETER SIZE (MM) (MM) (MM) 0.75 24/0.20 1 700 15.7 20 0.75 24/0.20 2 795 16.8 20 0.75 24/0.20 5 1598 25.1 25 0.75 24/0.20 10 2280 29.4 32 0.75 24/0.20 20 3630 37.3 40 0.75 24/0.20 30 4385 43.1 50S 0.75 24/0.20 50 6895 53.1 63S 1.0 1/1.13 1 710 15.8 20 1.0 1/1.13 2 828 17.0 20 1.0 1/1.13 5 1627 25.0 25 1.0 1/1.13 10 2275 29.6 32 1.0 1/1.13 20 3149 37.6 40 1.0 1/1.13 30 4420 42.6 50S 1.0 1/1.13 50 6964 53.5 63S 1.5 7/0.53 1 940 16.9 20 1.5 7/0.53 2 1051 19.0 20 1.5 7/0.53 5 1973 27.4 32 1.5 7/0.53 10 2823 33.2 32 1.5 7/0.53 20 4498 42.1 50S 1.5 7/0.53 30 6207 50.1 50 1.5 7/0.53 50 8961 61.0 63 CLEAT SIZE 0.7 0.7 1.0 1.2 1.6 1.8 TC9 0.7 0.7 1.0 1.2 1.6 1.8 TC9 0.7 0.8 1.1 1.4 1.8 2.0 TC10 Temperature limits: -20 to +63°C. *Bending radius: 5 x overall diameter. Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. Should not be installed at temperatures below 0°C. INSTRUMENTATION AND CONTROL CABLES LEAD SHEATHED ARMOURED WITH COLLECTIVE SCREEN (0.75MM2 TO 1.5MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 95 PAS5308 PART 1, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PAS5308 PART 2, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. CCC CODE PT1 PT2 7830 7831 7832 7833 7834 7835 N/A N/A N/A N/A N/A N/A 7870 7871 7872 7873 7874 7875 7930 7931 7932 7933 7934 7935 N/A N/A N/A N/A N/A N/A 7970 7971 7972 7973 7974 7975 CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND SIZE (MM2) (MM) PAIRS KG/KM DIAMETER SIZE (MM) (MM) (MM) 0.75 24/0.20 2 1280 21.5 25 0.75 24/0.20 5 1810 26.0 25 0.75 24/0.20 10 2720 32.7 32 0.75 24/0.20 20 4270 40.9 50S 0.75 24/0.20 30 6000 46.3 50S 0.75 24/0.20 50 8330 58.5 63S 1.0 1/1.13 2 1280 22.3 25 1.0 1/1.13 5 1820 27.2 25 1.0 1/1.13 10 2750 34.2 40 1.0 1/1.13 20 4350 43.8 50S 1.0 1/1.13 30 6110 51.4 50 1.0 1/1.13 50 8350 62.5 63 1.5 7/0.53 2 1680 25.5 25 1.5 7/0.53 5 2300 30.0 32 1.5 7/0.53 10 4000 40.1 50S 1.5 7/0.53 20 6300 50.2 50 1.5 7/0.53 30 8110 57.6 63S 1.5 7/0.53 50 11160 70.6 75S CLEAT SIZE 0.9 1.1 1.4 1.8 2.0 TC10 0.9 1.1 1.4 1.8 TC9 TC10 1.1 1.2 1.6 2.0 TC10 TC12 Temperature limits: -20 to +65°C. *Bending radius: 15 x overall diameter. Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. Should not be installed at temperatures below 0°C. INSTRUMENTATION AND CONTROL CABLES LEAD SHEATHED ARMOURED WITH INDIVIDUAL AND COLLECTIVE SCREENS (0.75MM2 TO 1.5MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES - PAS5308 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 96 INSTRUMENTATION AND CONTROL CABLES PAS5308 PART 1 COLOUR CODING PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A WIRE BLACK BLACK BLUE BLACK BLUE GREEN BLACK BLUE GREEN BROWN BLACK BLUE GREEN BROWN WHITE BLACK BLUE GREEN BROWN WHITE RED BLACK BLUE GREEN BROWN B WIRE BLUE GREEN GREEN BROWN BROWN BROWN WHITE WHITE WHITE WHITE RED RED RED RED RED ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE YELLOW YELLOW YELLOW YELLOW PAIR NUMBER 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 A WIRE WHITE RED ORANGE BLACK BLUE GREEN BROWN WHITE RED ORANGE YELLOW BLACK BLUE GREEN BROWN WHITE RED ORANGE YELLOW GREY BLACK BLUE GREEN BROWN WHITE B WIRE YELLOW YELLOW YELLOW GREY GREY GREY GREY GREY GREY GREY GREY VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET TURQUOISE TURQUOISE TURQUOISE TURQUOISE TURQUOISE For individual screened pairs, identification will be Black/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue , Black, Green. PAS5308 PART 1 CORE IDENTIFICATION Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 97 PART 2 COLOUR CODING PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A WIRE WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLACK BLACK BLACK BLACK BLACK YELLOW YELLOW YELLOW YELLOW YELLOW WHITE/BLUE WHITE/BLUE WHITE/BLUE WHITE/BLUE WHITE/BLUE B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY PAIR NUMBER 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 A WIRE RED/BLUE RED/BLUE RED/BLUE RED/BLUE RED/BLUE BLUE/BLACK BLUE/BLACK BLUE/BLACK BLUE/BLACK BLUE/BLACK YELLOW/BLUE YELLOW/BLUE YELLOW/BLUE YELLOW/BLUE YELLOW/BLUE WHITE/ORANGE WHITE/ORANGE WHITE/ORANGE WHITE/ORANGE WHITE/ORANGE ORANGE/RED ORANGE/RED ORANGE/RED ORANGE/RED ORANGE/RED B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY For individual screened pairs, identification will be White/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue, White, Orange. PAS5308 PART 2 CORE IDENTIFICATION Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES PAS5308 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 98 INSTRUMENTATION AND CONTROL CABLES BSC (CORUS) STANDARD Plain annealed flexible copper conductors, PVC bedding, tinned annealed copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20 part 4, Type 134. Flame propagation to BS EN 50265 and IEC 60332-1. CCC CODE CONDUCTOR STRANDING SIZE (MM2) (MM) BSC1342C BSC1343C BSC1344C BSC1347C BSC13412C BSC13419C BSC13427C BSC13437C 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 Temperature limits: -20 to +70°C. *Bending radius: 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 NO. OF CORES 2 3 4 7 12 19 27 37 WEIGHT OUTSIDE KG/KM DIAMETER (MM) 420 13.4 452 13.8 490 14.4 579 15.9 906 19.5 1091 21.5 1562 25.5 1872 28.1 GLAND SIZE (MM) 20S 20S 20S 20S 20 20 25 32 SINGLE CLEAT 0.6 0.6 0.6 0.7 0.8 0.9 1.1 1.2 Should not be installed at temperatures below 0°C. 6 x overall diameter. CORE IDENTIFICATION: NO. OF CORES 2 3 4 7 12 19 27 37 INSTRUMENTATION CABLE TO BRITISH STEEL SPECIFICATION CES20 TYPE 134 (0.75MM2) COLOUR BROWN BLUE BROWN BLUE GREEN/YLW BROWN GREY GREEN/YLW BLACK RED BLUE GREEN YELLOW WHITE BLACK BROWN RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK GRN/ORANGE GREEN/GREY BROWN/YLW BRN/WHITE BRN/BLACK BROWN/GREY VIOLET/YLW VIOLET/BLACK VIOLET/WHT RED/GREY Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 99 Tinned annealed flexible copper conductors, PVC insulated and laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Orange. 300/500 volts grade. Type 143. Flame propagation to BS EN 50265 and IEC 60332-1. CCC CODE BSC1431P BSC1432P BSC1435P BSC14310P BSC14320P BSC14330P BSC14350P CONDUCTOR STRANDING SIZE (MM2) (MM) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 NO. OF PAIRS 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 Temperature limits: -20 to +70°C. *Bending radius: 1 2 5 10 20 30 50 WEIGHT OUTSIDE KG/KM DIAMETER (MM) 260 10.70 320 11.90 672 18.80 1112 24.30 1665 30.30 2525 36.5 4137 46 GLAND SIZE (MM) 20/16 20S 20 25 32 40 50 SINGLE CLEAT 0.5 0.5 0.8 1.0 1.2 1.6 2.0 Should not be installed at temperatures below 0°C. 6 x overall diameter. CORE IDENTIFICATION ACCORDING TO ENATS 09-6 SECTION 3 PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 INSTRUMENTATION CABLE TO BRITISH STEEL SPECIFICATION CES20 TYPE 143 (0.75MM2) A WIRE BLACK BLACK BLACK BLACK BLACK BLUE BLUE BLUE BLUE BLUE ORANGE ORANGE ORANGE ORANGE GREEN GREEN GREEN BROWN BROWN GREY BLACK BLACK BLACK BLACK WHITE B WIRE BLUE ORANGE GREEN BROWN GREY WHITE ORANGE GREEN BROWN GREY WHITE GREEN BROWN GREY WHITE BROWN GREY WHITE GREY WHITE WHITE RED YELLOW VIOLET RED PAIR NUMBER 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 A WIRE WHITE WHITE BLUE BLUE BLUE GREEN GREEN GREEN RED RED RED RED RED GREY GREY ORANGE ORANGE YELLOW YELLOW BROWN TURQUOISE TURQUOISE TURQUOISE TURQUOISE TURQUOISE B WIRE YELLOW VIOLET RED YELLOW VIOLET RED YELLOW VIOLET GREY ORANGE YELLOW BROWN VIOLET YELLOW VIOLET YELLOW VIOLET BROWN VIOLET VIOLET BLACK BLUE RED ORANGE YELLOW Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES INSTRUMENTATION AND CONTROL CABLES BSC (CORUS) STANDARD INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 100 INTERNAL TELEPHONE CABLES TYPE CW1308 Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC sheathed. To BPO CW(M) 1308. Sheath colour: White. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE STRANDING (MM2) No. OF PAIRS WEIGHT KGS/KM 13000 13001 13002 13004 13005 13006 13013 13007 13008 13009 13010 13012 13014 13016 13018 13020 13022 13023 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 2 3 4 6 10 10+E 12 15 20+E 25+E 30+E 40+E 50+E 60+E 80+E 100+E 160+E 320+E 18 24 35 47 70 102 80 95 126 163 200 273 365 412 501 687 1135 2306 E. denotes earth core. Temperature limits: -20 to +70°C. OVERALL DIAMETER (MM) 3.6 4.5 5.8 6.8 8.3 8.6 9.1 9.8 10.7 11.4 12.2 15 17.5 20 22.5 24 30.5 39.5 GLAND SIZE (MM) 20/16 20/16 20/16 20/16 20/16 20S 20S 20S 20 20 20 25 25 32 32 32 40 50 *Bending radius: 5 x overall diameter. Should not be installed at temperatures below 0°C. CORE IDENTIFICATION: PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 INTERNAL TELEPHONE CABLE TYPE CW1308 A B WIRE WIRE WHITE/BLUE BLUE/WHITE WHITE/ORANGE ORANGE/WHITE WHITE/GREEN GREEN/WHITE WHITE/BROWN BROWN/WHITE WHITE/GREY GREY/WHITE RED/BLUE BLUE/RED RED/ORANGE ORANGE/RED RED/GREEN GREEN/RED RED/BROWN BROWN/RED RED/GREY GREY/RED BLACK/BLUE BLUE/BLACK BLACK/ORANGE ORANGE/BLACK BLACK/GREEN GREEN/BLACK BLACK/BROWN BROWN/BLACK BLACK/GREY GREY/BLACK PAIR NUMBER 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 A B WIRE WIRE YELLOW/BLUE BLUE/YELLOW YELLOW/ORANGE ORANGE/YELLOW YELLOW/GREEN GREEN/YELLOW YELLOW/BROWN BROWN/YELLOW YELLOW/GREY GREY/YELLOW VIOLET/BLUE BLUE/VIOLET VIOLET/ORANGE ORANGE/VIOLET VIOLET/GREEN GREEN/VIOLET VIOLET/BROWN BROWN/VIOLET VIOLET/GREY GREY/VIOLET PINK/BLUE BLUE/PINK PINK/ORANGE ORANGE/PINK PINK/GREEN GREEN/PINK PINK/BROWN BROWN/PINK PINK/GREY GREY/PINK Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 101 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE 13050 13051 13052 13053 13054 13055 13056 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.28 0.28 0.28 0.28 0.28 0.28 0.28 1/0.6 1/0.6 1/0.6 1/0.6 1/0.6 1/0.6 1/0.6 NO. OF PAIRS **2 5 10 20 30 50 100 WEIGHT OVERALL KG/KM DIAMETER (MM) 170 9 238 12.07 454 15.91 496 17.18 697 18.1 1243 26.60 1825 29.8 GLAND SIZE (MM) 20/16 20S 20 20 20 32 32 CLEAT SIZE SINGLE 0.5 0.6 0.7 0.7 0.8 1.1 1.2 Core identification: See colour chart on page 104. ** 2 pair laid up in quad formation. Temperature limits: -20 to +70°C. Should not be installed at temperatures below 0°C. Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE 13081 13083 13084 13085 13086 13087 13088 13089 13090 13091 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 NO. OF PAIRS **2 5 10 15 20 25 30 40 50 60 75 100 WEIGHT OVERALL KG/KM DIAMETER (MM) 206 10.31 333 14.1 586 17.38 796 19.5 939 22.48 1245 21.3 1400 23.9 1686 28.2 1952 32.87 2183 35 2342 37 3613 41.8 GLAND SIZE (MM) 20S 20S 20 20 25 25 25 32 32 40 40 50S CLEAT SIZE SINGLE 0.5 0.6 0.7 0.8 0.9 0.9 1.0 1.2 1.4 1.4 1.6 1.8 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE 13101 13103 13104 13105 13106 13107 13108 13109 13110 - CONDUCTOR STRANDING SIZE (MM2) (MM) 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 NO. OF PAIRS **2 5 10 15 20 25 30 40 50 100 ** 2 pair laid up in quad formation. PVC INSULATED MULTIPAIR ARMOURED CABLE TO ESI STANDARD Temperature limits: -20 to +70°C. *Bending radius: 6 x overall diameter. WEIGHT OVERALL KG/KM DIAMETER (MM) 213 10.4 379 14 650 17.8 805 20 955 21.7 1256 24.3 1413 25.9 1700 28.6 2110 31.5 3628 42 GLAND SIZE (MM) 20/16 20S 20 20 25 25 25 32 32 50S CLEAT SIZE SINGLE 0.5 0.6 0.8 0.8 0.9 1.0 1.1 1.2 1.4 1.8 Core identification: See colour chart on page 104. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES COMMUNICATION CABLES - TELEPHONE ENATS 09-6 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 102 COMMUNICATION CABLES - TELEPHONE ENATS 09-6 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE 13381 13383 13384 13385 13386 13387 13388 13389 13390 13391 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 NO. OF PAIRS **2 5 10 15 20 25 30 40 50 100 WEIGHT OVERALL KG/KM DIAMETER (MM) 208 10.17 353 13.92 606 17.49 630 18.9 854 21.06 1159 23.2 1266 26.47 1549 28.82 1923 33.5 3000 43.4 GLAND SIZE (MM) 20S 20S 20 20 25 25 32 32 32 50S CLEAT SIZE SINGLE 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.8 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE PVC INSULATED MULTIPAIR ARMOURED CABLE TO ESI STANDARD 13401 13403 13404 13405 13406 13407 13408 13409 13410 13411 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 NO. OF PAIRS **2 5 10 15 20 25 30 40 50 100 WEIGHT OVERALL KG/KM DIAMETER (MM) 223 10.3 349 13.74 599 18.14 795 19.4 900 22.34 1159 23.5 1332 25.21 1435 28 1926 31.44 3041 44.7 GLAND SIZE (MM) 20S 20S 20 20 25 25 25 32 32 50S CLEAT SIZE SINGLE 0.5 0.6 0.8 0.8 0.9 1.0 1.0 1.2 1.4 1.8 Solid tinned annealed copper, polyethylene insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5. CCC CODE 13501 13503 13504 13506 13510 13511 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 NO. OF PAIRS **2 5 10 20 50 100 WEIGHT OVERALL KG/KM DIAMETER (MM) 200 9.5 326 13.7 598 17.47 783 20.7 1823 20.74 3041 41 GLAND SIZE (MM) 20/16 20S 20 25 25 50S CLEAT SIZE SINGLE 0.6 0.7 0.9 0.9 1.8 Solid tinned, annealed copper conductors, polyethylene insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain, wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5. CCC CODE 13601 13603 13604 13606 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.5 0.5 0.5 0.5 NO. OF PAIRS 1/0.8 1/0.8 1/0.8 1/0.8 **2 pair laid up in quad formation. Temperature limits: -20 to +70°C. *Bending radius: 8 x overall diameter. **2 5 10 20 WEIGHT OVERALL KG/KM DIAMETER (MM) 260 10.9 328 14.33 602 17.22 790 20.8 GLAND SIZE (MM) 20S 20S 20 25 CLEAT SIZE SINGLE 0.5 0.6 0.7 0.9 Core identification: See colour chart on page 104. Should not be installed at temperatures below 0°C or 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 103 Stranded plain annealed copper conductor,PVC insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS6346 / ENATS 09-6. Flame retardant to IEC 60332-3-24c. CCC CONDUCTOR STRANDING CODE SIZE (MM) 6942X2/5ESI 2.5 7/0.67 6943X2/5ESI 2.5 7/0.67 6944X2/5ESI 2.5 7/0.67 6947X2/5/7 2.5 7/0.67 6940/12X2/5/7 2.5 7/0.67 6940/19X2/5/7 2.5 7/0.67 6940/27X2/5/7 2.5 7/0.67 6940/37X2/5/7 2.5 7/0.67 NO. OF CORES 2 3 4 7 12 19 27 37 WEIGHT OVERALL GLAND SIZE SINGLE (KG/KM) DIAMETER (MM) CLEAT 329 12.2 20S 0.5 396 13.5 20S 0.6 423 14.4 20 0.6 672 17.2 20 0.7 967 21.3 25 0.9 1482 25.4 25 1.1 1920 29.3 32 1.2 2185 33.1 40 1.4 Should not be installed at temperatures below 0°C or above 40°C. Temperature limits: -30 to +70°C *Bending radius: 6 x Overall Diameter Core identification: White numbered cores. COMMUNICATION CABLES - TELEPHONE ENATS 09-6 PVC AND PE INSULATED ARMOURED CABLES TO ENATS STANDARD Solid plain annealed copper conductor, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6 issue 6 section 3 table 2 - induced voltage between the pairs up to 15kv. CCC CODE 13187 13188 - CONDUCTOR STRANDING SIZE (MM) 0.5 1/0.8 0.5 1/0.8 0.5 1/0.8 Temperature limits: -20 to +70°C *Bending radius: NO. OF PAIRS 7 19 37 WEIGHT 900 1800 3000 OVERALL GLAND SINGLE DIAMETER SIZE (MM) CLEAT 22.5 25 0.9 32.1 32 1.4 41.7 50S 1.8 Should not be installed at temperatures below 0°C or above 40°C. 8 x Overall Diameter Core identification: 7 pair: centre - red & yellow. outer layer - black & violet, orange & grey**, green & brown, orange & blue**, green & brown, orange & white**. 19 pair: centre - centre and first layer as 7 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. 37 pair: centre, first and second layer as 19 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. **denotes carrier pairs. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES UTILITY INDUSTRY PVC CONTROL CABLES, ENATS 09-6 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 104 CORE IDENTIFICATION ACCORDING TO ENATS 3.6 AND 4.5 SECTION 3.6 COLOUR CODING PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ENATS 09-6 SECTION 3.6 AND 4.5 CORE IDENTIFICATION A WIRE BLACK BLACK BLACK BLACK BLACK BLUE BLUE BLUE BLUE BLUE ORANGE ORANGE ORANGE ORANGE GREEN GREEN GREEN BROWN BROWN GREY BLACK BLACK BLACK BLACK WHITE B WIRE BLUE ORANGE GREEN BROWN GREY WHITE ORANGE GREEN BROWN GREY WHITE GREEN BROWN GREY WHITE BROWN GREY WHITE GREY WHITE WHITE RED YELLOW VIOLET RED PAIR NUMBER 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 A WIRE WHITE WHITE BLUE BLUE BLUE GREEN GREEN GREEN RED RED RED RED RED GREY GREY ORANGE ORANGE YELLOW YELLOW BROWN TURQUOISE TURQUOISE TURQUOISE TURQUOISE TURQUOISE B WIRE YELLOW VIOLET RED YELLOW VIOLET RED YELLOW VIOLET GREY ORANGE YELLOW BROWN VIOLET YELLOW VIOLET YELLOW VIOLET BROWN VIOLET VIOLET BLACK BLUE RED ORANGE YELLOW All two pair cables are in quad formation and colour coded in rotation Blue, Orange, Green, Brown. SECTION 4.5 COLOUR CODING PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 A WIRE WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLACK BLACK BLACK BLACK BLACK YELLOW YELLOW YELLOW YELLOW YELLOW B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY All two pair cables are in quad formation and colour coded in rotation - White, Red, Blue, Orange. For 30 pair cables the formation will be 3 X 10 pair units numbered - 1, 2 and 3. Each unit is lapped with coloured tape for identification as follows UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT10 BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW VIOLET If sub-units are used, binders for corresponding sub-units shall be the same colour. For 40 pair cables the formation will be 2 X 20 pair units numbered - 1 and 2. For 50 pair cables the formation will be 5 X 10 pair units numbered - 1, 2 3, 4 and 5. For 100 pair cables the formation will be 5 X 20 pair units numbered - 1, 2, 3, 4 and 5. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 105 Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, PE outer sheath. Black. To CW1128A. Flame propogation to BS4066 PT1 and IEC 332 PT1. CCC CODE STRANDING (MM) NO. OF CORES WEIGHT KG/KM OVERALL DIAMETER GLAND SIZE 13030 13031 13032 13034 13035 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 5 10 20 50 100 48 82 182 317 613 6.83 7.41 11.48 15.5 21.78 20/16 20/16 20 25 32 CLEAT SIZE (MM) 0.5 0.7 0.9 Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled solid polyethylene bedding, galvanised steel wire armour, PE outer sheath. Black. To BPO CW 1128A/1198A. (Concentric construction). Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE 13040 13041 13042 13043 13044 PETROLEUM JELLY FILLED TELEMETRY CABLE TO CW1128, CW1128/1198 AND BS3573 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.196 0.196 0.196 0.196 0.196 NO. OF PAIRS 1/0.5 1/0.5 1/0.5 1/0.5 1/0.5 5 10 20 50 100 WEIGHT OVERALL KG/KM DIAMETER (MM) (MM) 199 10.63 276 12.4 461 16.23 920 21.66 1416 26.58 GLAND SIZE SINGLE 20S 20S 20 25 32 CLEAT SIZE 0.5 0.5 0.7 0.9 1.1 Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, collective aluminium/mylar tape screen, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To BS3573 and CW1128/1198. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC CODE 13150 13151 13153 13154 CONDUCTOR STRANDING SIZE (MM2) (MM) 0.63 0.63 0.63 0.63 NO. OF PAIRS 1/0.9 1/0.9 1/0.9 1/0.9 5 10 20 50 WEIGHT OVERALL KG/KM DIAMETER (MM) (MM) 392 16.7 620 19.9 1078 24.8 2155 34.5 GLAND SIZE SINGLE 20 20 25 40 CLEAT SIZE 0.7 0.8 1.0 1.6 COLOUR SCHEME FOR BS3573 - UNIT CONSTRUCTION PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 A WIRE WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY Cables may be manufactured using 5pair sub-units coloured as 1-5 and 6-10 UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT 10 BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW VIOLET If sub-units are used binders for corresponding sub-units shall be the same colour. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES COMMUNICATION CABLES PETROLEUM JELLY FILLED INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 106 DEFENCE STANDARD 61-12 CONTROL CABLES Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder tape, tinned annealed copper wire braid screen, PVC outer sheath. Black. 440 volts grade. To Ministry of Defence Standard DEF 61-12 (Part 4 for 7/0.2 conductors, Part 5 for 16/0.2 conductors). Flame propogation to BS4066 PT1 and IEC 332 PT1. CCC CODE 722C 723C 724C 726C 728C 7212C 7218C 7225C 7236C 7250C 7260C 1622C 1623C 1624C 1626C 1628C 16210C 16212C 16218C 16225C 16236C 16250C 16260C CONDUCTOR STRANDING SIZE (MM2) (MM2) 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 NO. OF CORES WEIGHT KG/KM 2 3 4 6 8 12 18 25 36 50 60 2 3 4 6 8 **10 12 18 25 36 50 60 23 27 32 55 69 83 110 150 200 270 310 69 79 92 120 146 190 198 250 320 450 564 670 OVERALL DIAMETER (MM) 4.1 4.3 4.6 5.9 6.0 7.2 8.5 9.8 11.2 13.0 13.8 6.9 7.2 7.7 8.7 8.9 11.8 11.0 12.5 14.6 16.7 18.5 20.3 GLAND SIZE (MM) 16 16 16 16 16 16 20 20 20 25 25 16 16 16 20 20 20 20 20 25 25 32 32 Tinned annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulation, non-hygroscopic binder tape, tinned annealed copper wire braid screen, low smoke and zero halogen (LSZH) outer sheath. Black. 440 volt grade. Generally to ministry of Defence Standard DEF61-12 Part 5 LSF. CCC CODE LSF1622C LSF1623C LSF1624C LSF1626C LSF16212C LSF16218C LSF16225C CONDUCTOR STRANDING SIZE (MM2) (MM2) 0.50 0.5 0.5 0.5 0.5 0.5 0.5 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 ** Laid up in a pair configuration. Temperature limits: -55 to +70°C. *Bending radius: NO. OF CORES WEIGHT KG/KM 2 3 4 6 12 18 25 69 79 92 120 198 250 320 OVERALL DIAMETER (MM) 6.9 7.2 7.7 8.7 11.0 12.5 14.6 GLAND SIZE (MM) 16 16 16 20 20 20 25 Core identification: See colour chart on page 107. Should not be installed at temperatures below 0°C. 6 x overall diameter. DEFENCE STANDARD SCREENED MULTICORE CABLE ‘C’ TYPE Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 107 COLOUR CODING CORE NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 36 COLOUR RED BLUE GREEN YELLOW WHITE BLACK BROWN VIOLET ORANGE PINK TURQUOISE GREY RED/BLUE GREEN/RED YELLOW/RED WHITE/RED RED/BLACK YELLOW/BLUE YELLOW/BLUE WHITE/BLUE BLUE/BLACK ORANGE/BLUE GREEN/BLUE GREY/BLUE YELLOW/GREEN WHITE/GREEN GREEN/BLACK ORANGE/GREEN GREY/GREEN YELLOW/BROWN WHITE/BROWN BROWN/BLACK GREY/BROWN YELLOW/VIOLET VIOLET/BLACK VIOLET/BLACK WHITE/VIOLET Where 2 colours are shown the core is striped e.g. Red/Blue - the core is striped Red with Blue. DEFENCE STANDARD 61-12 PARTS 4 & 5 CORE IDENTIFICATION INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES DEFENCE STANDARD 61-12 CONTROL CABLES INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 108 COMPENSATING AND THERMOCOUPLE CABLES NON-ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1. NO OF PAIRS SIZE (MM2) 1 2 5 10 20 0.75 0.75 0.75 0.75 0.75 STRANDING OVERALL GLAND (MM) DIAMETER SIZE (MM) (MM) 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 6.7 7.7 13.7 18.1 23.9 Temperature limits: -30 to +105°C. *Bending radius: 20/16 20/16 25 25 32 JX CCC CODE 7500 7501 7503 7505 7507 KCB KX CCC CCC CODE CODE (WAS VX) 7530 7570 7531 7571 7533 7573 7537 7575 7539 7577 TX CCC CODE 7550 7551 7553 7557 7559 Core identification: See colour chart on page 93. Should not be installed at temperatures below 0°C. 5 x overall diameter. ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1. NO OF PAIRS SIZE (MM2) 1 2 5 10 20 0.75 0.75 0.75 0.75 0.75 Temperature limits: -30 to +105°C. *Bending radius: 6 x overall diameter. PVC INSULATED COLLECTIVE SCREENED THERMOCOUPLE EXTENSION AND COMPENSATING CABLE (0.75MM2) STRANDING OVERALL GLAND (MM) DIAMETER SIZE (MM) (MM) 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 11.1 12.3 19.2 24.7 30.7 20/16 20/16 20 25 32 JX CCC CODE 7600 7601 7603 7605 7607 KCB KX CCC CCC CODE CODE (WAS VX) 7640 7700 7641 7701 7643 7703 7645 7705 7647 7707 TX CCC CODE 7660 7661 7663 7665 7667 Core identification: See colour chart on page 109. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 109 COLOUR CODING EX JX KX NX TX UX VX +- +- +- +- +- +- +- CODE BRITISH BS1843: 1952 +- +- +- +- +- +- +- AMERICAN ANSI +- +- +- +- +- GERMAN DIN +- +- +- +- RC/SC KCB +- +- IEC 584-3 +- COLOUR CODING OF THERMOCOUPLE EXTENSION AND COMPENSATING CABLE +- +- +- +- +- IEC 584-3 INTRINSICALLY SAFE INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES COMPENSATING AND THERMOCOUPLE CABLES INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 110 TRAFFIC SIGNALLING CABLES TRAFFIC CONTROL CABLE WITH ARMOUR Plain annealed solid copper conductors, PVC insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath, colour orange, generally to BS6346/87 CCC CODE TRAF4X1 TRAF8X1 TRAF12X1 TRAF16X1 TRAF20X1 TRAF4X1/5 TRAF8X1/5 TRAF12X1/5 TRAF16X1/5 TRAF20X1/5 TRAF8X1ESWA* CONDUCTOR STRANDING SIZE (MM2) (MM) 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.0 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.38 1/1.38 1/1.13 NO. OF CORES WEIGHT KG/KM 4 8 12 16 20 4 8 12 16 20 8 325 413 567 774 905 363 534 704 836 1040 533 OVERALL DIAMETER (MM) 13.3 15.6 17.9 19.9 22.0 12.5 15.8 18.5 20.0 21.5 16.3 GLAND SIZE (MM) 20S 20S 20 20 25 20S 20 20 20 25 20 LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, PVC insulated, PVC sheathed, colour orange, generally to BS6346/87, 600/1000v grade. CCC CODE PVC INSULATED ARMOURED TRAFFIC SIGNAL CABLE, LOOP FEEDER CABLE AND LOOP DETECTOR CABLE TRAF8X1NA TRAF12X1NA TRAF8X1E* CONDUCTOR STRANDING SIZE (MM2) (MM) 1.0 1.0 1.0 1/1.13 1/1.13 1/1.13 NO. OF CORES WEIGHT KG/KM 8 12 8 218 305 523 OVERALL DIAMETER (MM) 12.6 13.5 14.49 BRASS A2 GLAND 20 25 25 Temperature limits: -15 to +70°C. Core identification: 4 core - Red, Blue, Yellow, Green. 8 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange. * includes additional 6mm2 integral earth conductor 12 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue Violet. 16 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red. 20 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, Violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red, Violet/Red, Orange/Red, Green/Red, Blue/White. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 111 LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene outer sheath, colour orange, 600/1000v grade. CCC CODE LOOP2X1/5 LOOP4X1/5 LOOP2X2/5 LOOP4X2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 2.5 2.5 1/1.38 1/1.38 1/1.78 1/1.78 NO. OF CORES WEIGHT KG/KM 2 (1pr) 4 (2pr) 2 (1pr) 4 (2pr) 80 123 110 180 OVERALL DIAMETER (MM) 9.0 9.1 9.3 10.7 GLAND SIZE (MM) 20S 20S 20S 20S Temperature limits: -15 to +70°C. *Bending radius: Core identification: 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. 6 x overall diameter. Should not be installed at temperatures below 0°C. TRAFFIC CONTROL CABLE ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, polyethylene outer sheath. Generally to BS6346/87. Outer sheath colour: Orange. 600/1000 volts grade. CCC CODE LOOP2X1/5SWA LOOP4X1/5SWA LOOP2X2/5SWA LOOP4X2/5SWA CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 2.5 2.5 1/1.38 1/1.38 1/1.78 1/1.78 NO. OF CORES WEIGHT KG/KM 2 (1pr) 4 (2pr) 2 (1pr) 4 (2pr) 235 300 279 383 OVERALL DIAMETER (MM) 11.8 12.7 12.5 15.0 GLAND SIZE (MM) 20S 20S 20S 20 Temperature limits: -15 to +70°C. *Bending radius: Core identification: 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. 6 x overall diameter. Should not be installed at temperatures below 0°C. LOOP DETECTOR CABLE Tinned flexible copper conductor, ethylene propylene rubber insulated (EPR), polychloroprene sheathed (PCP), 600/100v generally to BS6500 + BS6195, sheath colour black. CCC CODE LOOP1/5 LOOP2/5 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 2.5 NO. OF CORES WEIGHT KG/KM 1 1 53.8 64.0 30/.025 50/0.25 Temperature limits: -30 to +85°C. *Bending radius: 6 x overall diameter. PVC INSULATED ARMOURED TRAFFIC SIGNAL CABLE, LOOP FEEDER CABLE AND LOOP DETECTOR CABLE OVERALL DIAMETER (MM) 7.0 7.9 GLAND SIZE (MM) 20S 20S Should not be installed at temperatures below -25°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TRAFFIC SIGNALLING CABLES 113 DATA AND COAXIAL CABLES DATA AND COAXIAL CABLES 114 DATA, COAXIAL AND LAN CABLES BELDEN EQUIVALENTS: 8138/SWA/LSF 8 PAIR 28AWG COLLECTIVE SCREEN PLUS STEEL WIRE ARMOUR,LSF SHEATH. 8471 1 PAIR 16AWG UNSCREENED, PVC SHEATH. 8471/LSF 1 PAIR 16AWG UNSCREENED, PVC SHEATH. 8719 1 PAIR 16AWG COLLECTIVE SCREEN, PVC SHEATH. 8719/LSF 1 PAIR 16AWG COLLECTIVE SCREEN, LSF SHEATH. 8723/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN ,LSOH SHEATH. 8723/SWA/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN PLUS STEEL WIRE ARMOUR, LSF SHEATH. 8760 1 PAIR 18AWG COLLECTIVE SCREEN. PVC SHEATH. 8760/LSF 1 PAIR 18AWG COLLECTIVE SCREEN. LSOH SHEATH. 8761 1 PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. 8761/LSF 1 PAIR 22AWG INDIVIDUAL SCREEN, LSOH SHEATH. 1 PAIR 20AWG COLLECTIVE SCREEN, PVC SHEATH. 8762 8762/LSF 1 PAIR 20AWG COLLECTIVE SCREEN, LSOH SHEATH. 3 PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. 8777 8778 6 PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH. 1 PAIR 22AWG COLLECTIVE SCREEN, PVC SHEATH. 9182 9463 TWIN AXIAL 20AWG, PVC SHEATH. 9463/SWA/PVC TWIN AXIAL 20AWG PLUS STEEL WIRE ARMOUR, PVC SHEATH. 9501 1 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9501/LSF 1 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9502 2 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9502/LSF 2 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9503 3 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9503LSF 3 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9504 4 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9504LSF 4 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9505LSF 5 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9506 6 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH. 9506LSF 6 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9729 2 PAIR 24AWG INDIVIDUAL SCREEN, PVC SHEATH. 9773 3 PAIR 18AWG INDIVIDUAL SCREEN, PVC SHEATH. 9841LSF 1 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. 9842LSF 2 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH. DATA AND COAXIAL CABLES COAXIAL CABLES CT100 CT100LSOH WF100BK WC100BK WF125BR CT125 CT125LSOH CT125BR CT125RBS CT167 CT167RBS RG11AU RG11SWA RG58 RG59BU RG59LSOH RG59SWA RG62AU RG62SWA URM202 URM203 URM70 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, PE DIELECTRIC, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, DIRECT BURIAL SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH. 75OHMDOUBLESCREENED,LOWLOSSCOAX,FOAMFILLED,DIRECTBURIALSHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. 75OHMBRAIDEDSCREEN,SOLIDPEDIELECTRICPLUSSTEELWIREARMOUR,PVCSHEATH. 50 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, LSOH SHEATH. 75OHMBRAIDEDSCREEN,SOLIDPEDIELECTRICPLUSSTEELWIREARMOUR,PVCSHEATH. 93 OHM BRAIDED SCREEN, PETUBE AND THREAD, PVC SHEATH. 93 OHM BRAIDED SCREEN, PETUBE AND THREAD PLUS SWA, PVC SHEATH. 75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH. UTP CABLES 4UTPCAT5E 4UTPCAT5EBU 4UTPCAT5ELSF 4FTPCAT5E 4FTPCAT5ELSF 4UTPCAT5EDUCT 4FTPCAT5EDUCT 4FTPCAT5ESWA 4UTPCAT6 4UTPCAT6LSF ENHANCED UNSCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH. ENHANCED UNSCREENED 4 PAIR CAT 5 E, BLUE PVC SHEATH. ENHANCED UNSCREENED 4 PAIR CAT 5 E, LSFVIOLET SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E, LSFVIOLET SHEATH. ENHANCED UNSCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E PLUS SWA, LSF BLACK SHEATH. UNSCREENED 4 PAIR CAT 6, GREY PVC SHEATH. UNSCREENED 4 PAIR CAT 6, LSFVIOLET SHEATH. 115 RAILWAY CABLES RAILWAY CABLES RAILWAY CABLES 116 RAILWAY SIGNALLING CABLES Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS76552.3 for types B1, LSZH insulated for types A1, A2, A3. Heavy duty PCP RS2 sheath for types A1 & B1, LSZH sheath for types A2 & A3. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). RAILWAY CABLES SIGNALING (0.75MM2 - 95MM2) CCC CODE RAIL CODE A11X/75BR A11X/75RD A11X/75OR A11X/75GY A11X/75VIR A11X/75BK A11X115BK A21X/75 A21X115 A32X/75 A34X/75 A36X/75 A310X/75 A314X/75 A336X/75 A348X/75 B11X2/5 B11X10 B11X35 B22X1/5 B22X2/5 B22X10 B22X16 B22X35 B22X70 B22X95 B24X/75 B24X1/5 B24X2/5 B24X10 B27X/75 B27X1/5 B27X2/5 B210X/75 B210X1/5 B210X2/5 B212X/75 B26PX/75 B212X1/5 B212X2/5 B219X/75 B219X1/5 B219X2/5 B227X/75 B227X1/5 B227X2/5 B237X/75 B237X1/5 B237X2/5 B248X/75 B248X1/5 B248X2/5 6/120002 6/120003 6/120004 6/120005 6/120006 6/120007 6/120008 6/120020 6/120024 6/120040 6/120041 6/120042 6/120043 6/120044 6/120045 6/120046 6/120061 6/120062 6/120063 6/120081 6/120082 6/120083 6/120113 6/120084 6/120085 6/120086 6/120087 6/120088 6/120089 6/120090 6/120091 6/120092 6/120093 6/120094 6/120095 6/120096 6/120111 6/120097 6/120098 6/120099 6/120100 6/120101 6/120102 6/120103 6/120104 6/120105 6/120106 6/120107 6/120108 6/120109 6/120110 Temperature limits: -25 to +85°C. *Bending radius: RAIL TYPE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SIZE CORES (KG/KM) DIAMETER SIZE (MM2) A1 Brown 0.75 7/0.37 1 16 2.95 N/A A1 Red 0.75 7/0.37 1 16 2.95 N/A A1 Orange 0.75 7/0.37 1 16 2.95 N/A A1 Grey 0.75 7/0.37 1 16 2.95 N/A A1 Violet 0.75 7/0.37 1 16 2.95 N/A A1 Black 0.75 7/0.37 1 16 2.95 N/A A1 Black 1.15 16/0.30 1 20 3.25 N/A A2 0.75 7/0.37 1 30 4.50 N/A A2 1.15 16/0.30 1 35 4.80 20/16 A3 0.75 7/0.37 2 67 7.75 20/16 A3 0.75 7/0.37 4 108 9.20 20S A3 0.75 7/0.37 6 160 11.10 20S A3 0.75 7/0.37 10 259 14.35 25 A3 0.75 7/0.37 14 495 15.75 25 A3 0.75 7/0.37 36 752 24.20 32 A3 0.75 7/0.37 48 963 27.50 40 B1 2.5 7/0.67 1 34 8.05 20/16 B1 10 7/1.35 1 205 10.60 20S B1 35 19/1.53 1 495 14.50 25 B2 1.5 7/0.53 2 135 10.75 20S B2 2.5 7/0.67 2 170 11.80 20 B2 10 7/1.35 2 443 16.85 25 B2 16 7/1.70 2 625 18.80 25 B2 35 19/1.53 2 1232 25.05 32 B2 70 19/2.14 2 2043 64.80 75 B2 95 19/2.52 2 2945 74.70 90 B2 0.75 7/0.37 4 150 11.50 20S B2 1.5 7/0.53 4 220 12.30 20 B2 2.5 7/0.67 4 295 13.35 20 B2 10 7/1.35 4 675 19.0 32 B2 0.75 7/0.37 7 225 13.25 20 B2 1.5 7/0.53 7 370 14.20 25 B2 2.5 7/0.67 7 500 15.50 25 B2 0.75 7/0.37 10 280 16.20 25 B2 1.5 7/0.53 10 401 17.50 25 B2 2.5 7/0.67 10 680 19.20 25 B2 0.75 7/0.37 12 321 16.65 25 B2 0.75 7/0.37 6pr 469 22.15 32 B2 1.5 7/0.53 12 410 18.00 25 B2 2.5 7/0.67 12 730 19.80 25 B2 0.75 7/0.37 19 425 19.15 25 B2 1.5 7/0.53 19 615 20.80 32 B2 2.5 7/0.67 19 815 22.95 32 B2 0.75 7/0.37 27 606 22.60 32 B2 1.5 7/0.53 27 897 25.00 32 B2 2.5 7/0.67 27 1200 27.65 40 B2 0.75 7/0.37 37 786 22.60 32 B2 1.5 7/0.53 37 1126 28.25 40 B2 2.5 7/0.67 37 1600 31.25 40 B2 0.75 7/0.37 48 972 28.95 40 B2 1.5 7/0.53 48 1280 31.60 40 B2 2.5 7/0.67 48 1960 35.10 50S Core identification: Black with white numbers. 8 x overall diameter. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 117 Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS7655-3.2. Heavy duty PCP RS2 sheath for types C1 + C2, LSZH sheath for types D1, D2, E1+E2. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC CODE RAIL CODE RAIL TYPE C11X2/5 C22X2/5 C24X2/5 C27X2/5 C210X2/5 C212X2/5 C216X2/5 D11X/75 D11X1/5 D11X2/5 D11X10 D11X35 D22X1/5 D22X2/5 D22X10 D22X16 D22X35 D24X1/5 D27X1/5 D210X1/5 D212X1/5 D219X1/5 D227X/75 D227X1/5 D227X2/5 D237X/75 D237X1/5 D237X2/5 D248X/75 D248X1/5 D248X2/5 E11X2/5 E22X2/5 E24X2/5 E27X2/5 E210X2/5 E212X2/5 6/120130 6/120140 6/120141 6/120142 6/120143 6/120144 6/120145 6/120211 6/120212 6/120213 6/120214 6/120215 6/120216 6/120217 6/120218 6/1220226 6/120219 6/120223 6/120228 6/120231 6/120234 6/120237 6/120238 6/120239 6/120240 6/120241 6/120242 6/120243 6/120244 6/120245 6/120246 6/120172 6/120170 6/120171 6/120173 6/120174 6/120175 C1 C2 C2 C2 C2 C2 C2 D1 D1 D1 D1 D1 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 E1 E2 E2 E2 E2 E2 CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SIZE CORES (KG/KM) DIAMETER SIZE (MM2) 2.5 50/0.25 1 174 12.60 25 2.5 50/0.25 2 342 16.85 25 2.5 50/0.25 4 445 18.65 25 2.5 50/0.25 7 590 42.40 50 2.5 50/0.25 10 784 25.55 40 2.5 50/0.25 12 868 26.25 40 2.5 50/0.25 16 980 28.65 40 0.75 7/0.37 1 25 7.30 20/16 1.5 7/0.53 1 30 7.65 20/16 2.5 7/0.67 1 34 8.05 20/16 10 7/1.35 1 205 10.60 20S 35 19/1.53 1 495 14.50 25 1.5 7/0.53 2 135 10.75 20S 2.5 7/0.67 2 170 11.80 20 10 7/1.35 2 443 16.85 25 16 7/1.70 2 625.0 20.9 32 35 19/1.53 2 1232 25.05 40 1.5 7/0.53 4 200.0 13.2 25 1.5 7/0.53 7 370.0 15.8 25 1.5 7/0.53 10 401.0 19.4 32 1.5 7/0.53 12 410.0 17.3 32 1.5 7/0.53 19 615.0 23.1 32 0.75 7/0.37 27 606 22.60 32 1.5 7/0.53 27 897 25.00 32 2.5 7/0.67 27 1200 27.65 40 0.75 7/0.37 37 786 25.55 32 1.5 7/0.53 37 1126 28.25 40 2.5 7/0.67 37 1600 31.25 40 0.75 7/0.37 48 972 28.95 40 1.5 7/0.53 48 1280 31.60 40 2.5 7/0.67 48 1960 35.10 50S 2.5 50/0.25 1 174 12.60 20 2.5 50/0.25 2 342 16.85 25 2.5 50/0.25 4 445 18.65 25 2.5 50/0.25 7 590 21.20 32 2.5 50/0.25 10 784 25.55 32 2.5 50/0.25 12 868 26.25 40 Temperature limits: -25 to +85°C. *Bending radius: 8 x overall diameter. Core identification: Black with white numbers. RAILWAY CABLES SIGNALING (0.75MM2 - 35MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. RAILWAY CABLES RAILWAY SIGNALLING CABLES RAILWAY CABLES 118 RAILWAY TRAIN PROTECTION WARNING CABLES Flexible tinned copper conductors to BS6360, EPR insulated to BS7655-2.3, separate drain wire,single aluminium tape screen (polyester backed). Black Heavy duty PCP RS2 sheath to BS7655 for type C3, LSZH sheath for type E3. Manufactured to Network Rail specification NR/PS/SIG/OOOO5 (formerly RT/E/PS/00005). CCC CODE RAIL CODE RAIL TYPE C3TPWS E3TPWS 6/160086 6/160090 C3TPWS E3TPWS CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SIZE (MM) 2.5 2.5 CORES (KG/KM) DIAMETER 50/0.25 50/0.25 1PR 1PR 250 250 17.50 17.50 SIZE 25 25 Temperature limits: -25 to +85°C. *Bending radius: 8 x overall diameter. RAILWAY CABLES TRAIN PROTECTION WARNING POINT HEATER RAILWAY POINT HEATER CABLES Flexible tinned copper conductor to B6360, EPR insulation type GP4 to BS7655, black PCP type EM2 sheath to BS7655. Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly R/E/PS/40045). CCC CODE RAIL CODE 3184PH1/5 3188PH1/5 3188PH2/5 6388PH4 6388PH6 6388PH10 6388PH16 6/150002 6/153002 6/153103 - CONDUCTOR SIZE (MM2) 1.5 1.5 2.5 4.0 6.0 10.0 16.0 STRANDING NO. OF CORES 30/0.25 30/0.25 50/0.25 56/0.30 84/0.30 75/0.40 118/0.40 4 8 8 8 8 8 8 WEIGHT OVERALL (KG/KM) DIAMETER 220 460 510 830 1040 1799 2480 14.32 18.44 23.36 23.60 25.60 31.70 36.20 GLAND SIZE 25 25 32 32 32 40 50S Temperature limits: -30 to +70°C. Core identification: 4 core - Yellow, Yellow, Blue, Blue. 8 core - Yellow, Yellow, Blue, Blue, Brown, Brown, Black, Black. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 119 Solid plain annealed copper conductors, polyethylene insulation, petroleum jelly filled, polyethylene outer sheath. Manufactured to Network Rail specification RT/E/PS/0031. CCC CODE RAIL CODE F1D0902 F1D0910 F1D0912 F1D0919 F1D0924 F1D1402 F1D1410 F1D1412 F1D1419 F1D1424 6/170001 6/170002 6/170003 6/170004 6/170005 6/170121 6/170122 6/170123 6/170124 6/170125 CONDUCTOR STRANDING SIZE (MM2) 0.63 1/0.9 0.63 1/0.9 0.63 1/0.9 0.63 1/0.9 0.63 1/0.9 1.5 1/1.4 1.5 1/1.4 1.5 1/1.4 1.5 1/1.4 1.5 1/1.4 NO. OF PAIRS 2 10 12 19 24 2 10 12 19 24 WEIGHT OVERALL (KG/KM) DIAMETER 165 526 633 1034 1326 318 1020 1691 1691 2419 13.20 21.60 24.80 31.20 33.80 23.40 30.00 32.00 37.30 42.30 GLAND SIZE 25 32 32 40 50S 32 40 50S 50S 50S Core identification: RAILWAY CABLES AXLE COUNTING CABLES AND DATALINK PAIR NO 1 2 3 4 5 6 7 8 9 10 11 12 A WIRE WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED YELLOW YELLOW B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE PAIR NO 13 14 15 16 17 18 19 20 21 22 23 24 A WIRE YELLOW YELLOW YELLOW VIOLET VIOLET VIOLET VIOLET VIOLET TURQUOISE TURQUOISE TURQUOISE TURQUOISE B WIRE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN Two pair cables laid up in quad formation colour coded in rotation, Orange, White, Green, Black. Temperature limits: -40 to +70°C. *Bending radius: 15 x overall diameter RAILWAY DATALINK CABLE Solid copper conductor, polythylene insulation, aluminium/polyethylene laminated moisture barrier, polyethylene sheath black or blue. To BR1932. CCC CODE RAIL CODE STRANDING NO. OF CORES DATALINK2X1/27 DATALINK2X1/27BU DATALINK2X1/27LSF 6/166065 6/166065 6/166065 1/1.27 1/1.27 1/1.27 2 2 2 Temperature limits: PE sheath -40 to + 70°C LSZH sheath -10 to + 50°C WEIGHT OVERALL (KG/KM) DIAMETER 136 136 136 12.47 12.47 12.47 GLAND SIZE 25 25 25 *Bending radius: 15 x overall diameter Core identification: Blue, Red. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. RAILWAY CABLES RAILWAY AXLE COUNTING CABLES RAILWAY CABLES 120 RAILWAY AXLE COUNTING CABLE NON ARMOURED Solid tinned annealed copper conductors, polyethylene insulation (type 03 to BS6234), petroleum jelly filled (XPS and XQS types only), glass fibre weave, aluminium/polymer laminate tape, polyetheylene sheath XPS type (type 03C to BS6234) or LSZH XPZ type. Manufactured to Network Rail specification RT/E/PS/0031. Spec AzLM axle counter cable NRL2SIG30060. CCC CODE RAIL CODE CABLE TYPE XPS0902 XPS0910 XPS0912 XPS0919 XPS0924 XPS1402 XPS1410 XPS1412 XPS1419 XPS1424 XPZ0902 XPZ0910 XPZ0912 XPZ0919 XPZ0924 XPZ1402 XPZ1410 XPZ1412 XPZ1419 XPZ1419 006/170007 006/170008 006/170009 006/170034 006/170035 006/170036 006/170037 006/170038 006/170039 006/170040 006/170023 006/170024 006/170025 006/170026 006/170027 006/170028 006/170029 006/170030 006/170031 006/170032 XPS XPS XPS XPS XPS XPS XPS XPS XPS XPS XPZ XPZ XPZ XPZ XPZ XPZ XPZ XPZ XPZ XPZ CONDUCTOR STANDING NO. OF SIZE (MM) PAIRS 0.63 0.63 0.63 0.63 0.63 1.5 1.5 1.5 1.5 1.5 0.63 0.63 0.63 0.63 0.63 1.5 1.5 1.5 1.5 1.5 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/1.4 1/1.4 1/1.4 1/1.4 1/1.4 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/1.4 1/1.4 1/1.4 1/1.4 1/1.4 WEIGHT OVERALL (KG/KM) DIAMETER 2 10 12 19 24 2 10 12 19 24 2 10 12 19 24 2 10 12 19 24 215 530 584 810 982 320 910 1016 1460 1787 200 424 468 632 746 314 807 909 1284 1548 13.8 24.7 26.4 31.4 34.5 16.4 31.4 33.8 40.8 45.0 13.8 24.7 26.4 31.4 34.5 16.4 31.4 33.8 40.8 45.0 Temperature limits: - 25 to + 85°C *Bending radius: 7.5 x overall diameter Core identification: Table 6 core colours: Table 7 layer make-up: RAILWAY AXLE COUNTING CABLE NON ARMOURED PAIR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CORE COLOURS White White White White White Red Red Red Red Red Yellow Yellow Yellow Yellow Yellow Violet Violet Violet Violet Violet Turquoise Turquoise Turquoise Turquoise Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown NO. OF PAIRS 2 10 12 19 24 PAIR NOS. IN EACH LAYER CENTRE 1ST LAYER 1&2 1&2 3 -> 10 1 -> 3 4 -> 12 1 2 -> 7 1&2 3 -> 10 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 121 Solid plain annealed copper conductors to BS6360, polytheylene insulation, petroleum jelly filled, corrugated steel armour, polytheylene outer sheath. Manufactured to Network Rail specification NR/PS/TEL/00015 (formerly RT/E/PS/00015). CCC CODE RAIL CODE 13781 13784 13786 13788 13790 6/168061 6/168063 6/168064 6/168065 6/168066 CONDUCTOR STRANDING SIZE (MM2) 0.63 1/0.9 0.63 1/0.9 0.63 1/0.9 0.63 1/0.9 0.63 1/0.9 Temperature limits: -25 to +85°C. Core identification: 2 PAIR (laid up in quad formation) PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 A WIRE WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED NO. OF PAIRS 2 10 20 30 50 WEIGHT OVERALL (KG/KM) DIAMETER 250 520 820 915 1550 19.00 23.80 27.60 30.9 35.70 GLAND SIZE 20 25 32 32 32 Bending radius: 10 x overall diameter. B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY 20 PAIR (laid up in 4x5 pair) PAIR NUMBER 1 2 3 4 5 SUB-UNIT (CODE A) A WIRE WHITE WHITE WHITE WHITE WHITE B WIRE BLUE ORANGE GREEN BROWN GREY PAIR NUMBER 1 2 3 4 5 SUB-UNIT (CODE B) A WIRE RED RED RED RED RED B WIRE BLUE ORANGE GREEN BROWN GREY Each unit is lapped with coloured tape for identification as follows: UNIT NUMBER 1 2 3 4 UNIT CODE A B C D COLOUR OF BINDINGS BLUE BLUE ORANGE ORANGE 30 PAIR (laid up in 3x10 pair) 50 PAIR (laid up in 5x10 pair) PAIR NUMBER 1 2 3 4 5 6 7 8 9 10 COPPER TRACKSIDE CABLE SUB-UNIT (CODE A) A WIRE WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED Each unit is lapped with coloured tape for identification as follows: B WIRE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY UNIT NUMBER 1 2 3 4 5 COLOUR OF BINDINGS BLUE ORANGE GREEN BROWN GREY Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. RAILWAY CABLES RAILWAY COPPER TRACKSIDE COMMUNICATION CABLES RAILWAY CABLES 122 RAILWAY POWER AND TRACK FEEDER CABLES POWER CABLES Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath, Black to BR880 06/142639. 600/1000 volts grade to BS 5467. CCC CODE RAIL CODE SAC2X16NA SAC2X25NA SAC2X35NA SAC2X50NA SAC2X70NA SAC2X95NA SAC4X70NA 6/142419 6/142519 6/142609 6/142629 6/142639 6/142644 6/151469 CONDUCTOR SIZE (MM2) 16 25 35 50 70 95 70 Temperature limits: +90°C. *Bending radius: NO. OF CORES WEIGHT (KG/KM) OVERALL DIAMETER GLAND SIZE 2 2 2 2 2 2 4 420 455 525 620 840 1020 1750 14.30 16.60 18.00 20.40 22.80 26.20 30.60 25 25 25 32 32 40 40 Core identification: 2 core - Brown, Blue. 4 core - Blue, Brown, Black, Grey. 8 x overall diameter. RAILWAY CABLES POWER & TRACK FEEDER TRACK FEEDER CABLES Uncompacted circular stranded aluminium to BS6360 or uncompacted circular stranded tinned copper to BS6360. CSP sheathed type RS4 to BS6899, black. Manufactured to Network Rail specification NR/PS/ELP/21101 (formerly RT/E/S/21101). CCC CODE RAIL CODE POLARITY TRACK150 TRACK161 TRACK240 TRACK500 TRACK500CU TRACK630CU TRACK800 TRACK1000 TRACK240LSF TRACK800LSF TRACK1000LSF 6/116601 6/132340 6/132990 6/132840 6/132992 6/116612 6/132991 6/116610 - NEGATIVE NEGATIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE NEGATIVE POSITIVE CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SIZE CORES (KG/KM) DIAMETER SIZE (MM2) 150 AL 37/2.25 1 540 19.40 25 161 CU 91/1.53 1 1887 24.80 32 240 AL 61/2.25 1 1076 28.30 40 500 AL 61/3.20 1 2245 40.20 50 500 CU 91/2.65 1 5291 40.60 50 630 CU 127/2.52 1 6692 44.20 63S 800 AL 127/2.85 1 3255 48.50 63S 1000 AL 127/3.20 1 3943 53.00 63 240 AL 61/2.25 1 1076 28.3 40 800 AL 127/2.85 1 3255 48.5 63S 1000 AL 127/3.2 1 3943 53.0 63 Temperature limits: -25°C to +85°C. *Bending radius: Aluminium conductor - 10x overall diameter Copper conductor - 8x overall diameter Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 123 MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES 124 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2. CCC CODE 6571TQ1/5 6572TQ1/5 6573TQ1/5 6574TQ1/5 6575TQ1/5 6576TQ1/5 6577TQ1/5 6578TQ1/5 6570/10TQ1/5 6570/12TQ1/5 6570/19TQ1/5 6570/27TQ1/5 6570/30TQ1/5 6570/37TQ1/5 6571TQ2/5 6572TQ2/5 6573TQ2/5 6574TQ2/5 6575TQ2/5 6576TQ2/5 6577TQ2/5 6578TQ2/5 6570/10TQ2/5 6570/12TQ2/5 6570/19TQ2/5 6570/27TQ2/5 6570/30TQ2/5 6570/37TQ2/5 6571TQ4 6572TQ4 6573TQ4 6574TQ4 6575TQ4 6577TQ4 6571TQ6 6572TQ6 6573TQ6 6574TQ6 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 NO. OF CORES WEIGHT KG/KM 1 2 3 4 5 6 7 8 10 12 19 27 30 37 1 2 3 4 5 6 7 8 10 12 19 27 30 37 1 2 3 4 5 7 1 2 3 4 49 125 150 180 190 240 275 295 360 440 740 970 1015 1220 63 160 190 240 280 470 355 398 519 650 860 1220 1270 1610 90 240 280 360 425 530 115 305 370 475 OVERALL DIAMETER (MM) 5.5 8.9 9.4 10.3 11.0 12.2 12.5 13.3 16.2 16.4 19.3 23.5 24.3 26.0 6.0 9.8 10.4 11.4 12.6 16.9 13.7 15.3 17.7 18.3 21.7 26.3 27.1 29.5 6.9 12.0 12.7 13.9 15.3 17.7 7.5 13.1 13.9 15.4 UKOOA CODE WF102 WF202 WF302 WF402 WF502 WF702 WFA02 WFB02 WFC02 WFD02 WF103 WF203 WF303 WF403 WF503 WF703 WFA03 WFB03 WFC03 WFD03 WF104 WF204 WF304 WF404 WF504 WF704 WF106 WF206 WF306 WF406 Core identification: White with Black numbers. Single cores available in either Black or Green/Yellow outer sheath. Should not be installed at temperatures below -15°C. EPR INSULATED NON-ARMOURED SHIPWIRING CABLE (1.5MM2 TO 6MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 125 Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2. CCC CODE 6571TQ10 6572TQ10 6573TQ10 6574TQ10 6571TQ16 6572TQ16 6573TQ16 6574TQ16 6571TQ25 6572TQ25 6573TQ25 6574TQ25 6571TQ35 6572TQ35 6573TQ35 6574TQ35 6571TQ50 6572TQ50 6573TQ50 6574TQ50 6571TQ70 6573TQ70 6574TQ70 6571TQ95 6573TQ95 6574TQ95 6571TQ120 6573TQ120 6571TQ150 6571TQ185 6571TQ240 6571TQ300 6571TQ400 6571TQ500 6571TQ630 CONDUCTOR STRANDING SIZE (MM2) (MM) 10 10 10 10 16 16 16 16 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 95 95 95 120 120 150 185 240 300 400 500 630 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 19/1.35 19/1.35 19/1.35 19/1.35 19/1.53 19/1.53 19/1.53 19/1.53 19/1.78 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 37/1.78 37/1.78 37/1.78 37/2.03 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 91/2.36 91/2.65 127/2.52 NO. OF CORES WEIGHT KG/KM 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 3 4 1 3 4 1 3 1 1 1 1 1 1 1 165 470 595 745 230 655 830 1045 380 1090 1340 1680 490 1310 1630 2130 640 1720 2210 2840 870 3080 3950 1150 4060 5170 1440 5130 1770 2200 2780 3450 4400 5600 6910 OVERALL DIAMETER (MM) 9.0 16.0 17.2 18.9 10.1 18.3 19.5 21.7 12.4 22.9 24.4 27.1 13.6 25.3 27.1 30.1 15.5 29.0 30.9 34.6 17.5 35.3 39.2 19.6 40.3 45.1 21.4 44.4 23.8 26.3 29.5 32.6 36.7 40.5 44.4 UKOOA CODE WF110 WF210 WF310 WF410 WF116 WF216 WF316 WF416 WF125 WF225 WF325 WF425 WF135 WF235 WF335 WF435 WF150 WF250 WF350 WF450 WF170 WF370 WF470 WF195 WF395 WF495 WF10A WF30A WF10B WF10C WF10D WF10E WF10F WF10G WF10H Single core cables are available in Black or Green/Yellow outer sheath. Temperature limits: -30 to +85°C. *Bending radius: up to 25mm - 4 x overall diameter. above 25mm - 6 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. EPR INSULATED NON-ARMOURED SHIPWIRING CABLE (10MM2 TO 630MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES 126 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61304-1,2. CCC CODE 6582TQ1/5 6583TQ1/5 6584TQ1/5 6585TQ1/5 6586TQ1/5 6587TQ1/5 6580/12TQ1/5 6580/19TQ1/5 6580/27TQ1/5 6580/37TQ1/5 6582TQ2/5 6583TQ2/5 6584TQ2/5 6585TQ2/5 6586TQ2/5 6587TQ2/5 6580/12TQ2/5 6580/19TQ2/5 6580/27TQ2/5 6580/37TQ2/5 6582TQ4 6583TQ4 6584TQ4 6585TQ4 6587TQ4 CONDUCTOR STRANDING SIZE (MM2) (MM) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 NO. OF CORES WEIGHT KG/KM 2 3 4 5 6 7 12 19 27 37 2 3 4 5 6 7 12 19 27 37 2 3 4 5 7 300 325 395 407 425 525 790 1090 1515 1870 350 400 470 485 550 635 990 1390 1990 2500 480 530 585 700 897 OVERALL DIAMETER (MM) 13.3 13.8 15.0 15.2 16.5 17.2 21.7 24.7 29.3 33.2 14.2 15.0 16.1 16.9 18.2 18.5 23.9 27.6 33.2 36.7 16.6 17.3 18.4 20.2 22.7 UKOOA CODE WB202 WB302 WB402 WB702 WBA02 WBB02 WBC02 WBD02 WB203 WB303 WB403 WB503 WB703 WBA03 WBB03 WBC03 WBD03 WB204 WB304 WB404 WB504 WB704 Temperature limits: -30 to +85°C. *Bending radius: 6 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. EPR INSULATED BRAIDED ARMOUR SHIPWIRING CABLE (1.5MM2 TO 4MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 127 Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61304-1,2. CCC CODE 6582TQ6 6583TQ6 6584TQ6 6582TQ10 6583TQ10 6584TQ10 6582TQ16 6583TQ16 6584TQ16 6582TQ25 6583TQ25 6584TQ25 6582TQ35 6583TQ35 6584TQ35 6582TQ50 6583TQ50 6584TQ50 6582TQ70 6583TQ70 6584TQ70 6582TQ95 6583TQ95 6584TQ95 6582TQ120 6583TQ120 6584TQ120 6582TQ150 6583TQ150 6584TQ150 6583TQ185 6584TQ185 6583TQ240 6584TQ240 6583TQ300 6584TQ300 CONDUCTOR STRANDING SIZE (MM2) (MM) 6 6 6 10 10 10 16 16 16 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120 150 150 150 185 185 240 240 300 300 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 19/1.35 19/1.35 19/1.35 19/1.53 19/1.53 19/1.53 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 37/1.78 37/1.78 37/1.78 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 61/2.25 61/2.25 61/2.52 61/2.52 NO. OF CORES WEIGHT KG/KM 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 570 635 760 750 930 1080 1020 1190 1450 1500 1800 2500 1810 2400 2880 2510 3000 3670 2940 3980 4840 3813 5290 6310 4692 6480 7770 5634 7700 9400 9550 11520 12300 14840 14850 17938 OVERALL DIAMETER (MM) 17.9 18.7 20.1 21.0 22.4 24.0 23.7 24.9 26.9 29.0 30.7 33.6 31.0 34.0 36.2 36.0 38.1 41.0 36.0 42.8 46.1 40.9 48.5 52.6 44.9 52.9 57.4 48.9 57.9 63.1 63.8 69.6 71.5 78.3 78.8 84.9 UKOOA CODE WB206 WB306 WB406 WB210 WB310 WB410 WB216 WB316 WB416 WB225 WB325 WB425 WB235 WB335 WB435 WB250 WB350 WB450 WB270 WB370 WB470 WB295 WB395 WB495 WB20A WB30A WB40A WB20B WB30B WB40B WB30C WB40C WB30D WB40D WB30E WB40E Temperature limits: -30 TO +85°C. *Bending radius: 6 x overall diameter Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. EPR INSULATED BRAIDED ARMOURED SHIPWIRING CABLE (6MM2 TO 300MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES 128 MARINE AND OFFSHORE CABLES Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSZH) bedding tinned phosphor bronze braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts grade to IEC90092-353, IEC60331-21, IEC60332-2, IEC60332-222, IEC60751-2,2 and IEC61034-1,2. CCC CODE 6591TQ6 6591TQ10 6591TQ16 6591TQ25 6591TQ35 6591TQ50 6591TQ70 6591TQ95 6591TQ120 6591TQ150 6591TQ185 6591TQ240 6591TQ300 6591TQ400 6591TQ500 6591TQ630 CONDUCTOR STRANDING SIZE (MM2) (MM) 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 7/1.04 7/1.35 7/1.70 19/1.35 19/1.53 19/1.78 19/2.14 37/1.78 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 91/2.36 91/2.65 127/2.52 NO. OF CORES WEIGHT KG/KM 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 245 320 395 565 740 940 1270 1600 1930 2330 3000 3710 4480 5340 6540 8000 OVERALL DIAMETER (MM) 11.7 13.4 14.5 17.3 18.4 20.3 22.7 25.0 27.2 29.5 33.1 36.6 40.0 43.9 48.1 52.3 UKOOA CODE WAB06 WAB10 WAB16 WAB25 WAB35 WAB50 WAB70 WAB95 WABOA WABOB WABOC WABOD WABOE WABOF WABOG WABOH Temperature limits: -30 to +85°C. *Bending radius: 6 x overall diameter. Core identification: White. Should not be installed at temperatures below -15°C. EPR INSULATED SINGLE CORE BRAIDED SHIPWIRING CABLE (6MM2 TO 630MM2) Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 129 INSTALLATION ACCESSORIES INSTALLATION ACCESSORIES 131 LML LML Products Limited Since its inception in 1968, LML has designed, manufactured and supplied a comprehensive range of copper tube terminals including bespoke specials. With in-house tooling and electroplating facilities, LML will always provide a solution for its quality focused customers in compliance with BS EN ISO 9001:2000 Copper Tube Terminals LML terminals are manufactured from seamless copper tube to BS EN 12449 and feature bell mouth entry up to 400mm2 and chamfered entry from 500mm2 to 1000mm2. All terminals and splices (other than parallel splices) are provided with an inspection hole to ensure the conductor is fully inserted before crimping. Internal barrel diameters suit standard cables as defined in BS EN 6360. Standard finish is bright electro tin plating to BS EN 1872. Other finishes can be provided, e.g. nickel or silver. Terminals are independently tested to comply with BS EN 61238-1, and are also approved for military use and by London Underground. Crimp Tooling LML Products also supply a large range of manual hydraulic tools for crimping terminals from 1.5mm2 to 1000mm2. LML also supplies a range of hydraulic crimping tools with rechargeable battery. Med/High Voltage Crimp Terminals LML Products manufactures a range of copper tube terminals to suit 11kv and 33kv. We also manufacture water blocked splices and terminals. www. cmp-products .com SERVICES AND SUPPORT FROM CMP PRODUCTS CMP CMP PRODUCTS CMP Products offers a comprehensive training program for the installation of it's products. Whether you just need a video to show you how it's done, require practical demonstrations at your premises or indeed you require training on site for large groups, CMP is able to assist. We offer certified training on all of our products with all attendees receiving a training certificate following successful completion of the course to demonstrate competence. CERTIFIED TRAINING AVAILABLE • • • • • • • • for designers/specifiers for installers for a QA, QC Personnel installation video's available for all products in multiple languages for design engineers to assist with correct product selection to keep up with the latest standards wherever you need it, when you need it ALSO AVAILABLE from CMP Products • Breather Drain Plugs • Adaptors & Reducers • Stopper Plugs • Unions • Locknuts • Serrated Washers • Earth Tags • Entry Thread Seals • Shrouds 135 RAXTON LIMITED Raxton products are designed to solve the fundamental difficulties which exist due to the variety of thread forms currently in use within the electrical industry. These thread forms are predominantly Isometric, Imperial, N.P.T., BSP and PG. Problems caused by dissimilar threads can occur in many environments including industrial, EExd, EExe and mining. Raxton conversions are fully approved to meet these requirements, being certified by leading test authorities including BASEEFA, SIRA, ISSEP, KEMA, DET NORSKE VERITAS and Standards Association of Australia. They are marked accordingly. Standard material is brass and readily available alternatives include mild steel, stainless steel and aluminium. Our EExe range is also available in glass filled nylon. ADAPTORS REDUCERS HEXAGON HEAD PLUGS RIGHT ANGLE ADAPTORS MALE TO MALE ADAPTORS UNIONS STOPPING PLUGS EARTH LEAD ADAPTORS THREADED EARTH PLATES NYLON GLANDS SCREWED NIPPLING COUPLERS BUSHES SHROUDS LOCKNUTS/LOCKRINGS EARTH TAGS WASHERS Legrand cable management solutions... LEGRAND CA B L E M A N AG E M E N T www.legrand.co.uk 138 W. J. FURSE & COMPANY LIMITED E-Klips is a division of W J Furse & Co Ltd, a multi-disciplined engineering and marketing company employing nearly 200 people worldwide. We are the largest UK manufacturer of a comprehensive range of industrial fasteners, which are made available to the electrical/mechanical industry. They provide a quick, efficient method of fixing without drilling or bracket making. Our commitment to quality has set industry standards while our new designs bring you all the benefits of E-Klips continuous product development philosophy. Wholly manufactured in the UK, E-Klips fasteners can be found throughout Europe and in many other countries in the world where our unequalled combination of speed and quality is properly appreciated. This combination can give you savings of up to 60% over a complete installation – a very significant competitive advantage! E-Klips are available for every type of installation through our established distributor network who are fully supported by our stocks and service. So, if you would like to use the faster fastener, simply specify E-Klips and put your opposition in the shade. 139 W. J. FURSE & COMPANY LIMITED As a recognised world leader in the Earthing and Lightning Protection Industry, W J Furse has a proven track record spanning over one hundred years. The range complies with the requirements of relevant British and World standards, and our design and manufacturing quality control systems are independently assessed and approved to ISO9001. W J Furse can also offer a level of competitiveness, service and technical support that is the envy of competitors both in the UK and overseas. Our extensive range includes the following: Earth Rods Copperbond, solid copper and stainless steel. Earth Pits Lightweight, high performance plastic and regular duty concrete pits. Fittings Clamps, bonds, clips and accessories in copper and aluminium alloys and plastics suitable for flat tape and solid circular conductor systems. Conductors An extensive range of copper and aluminium conductors available bare and PVC covered. Specialist Products Including weldable and adhesive conductor clips and earth rod seals. Furseweld Process An exothermic welding process with a simple self contained method of forming high quality electrical connections which do not require external power or heat source, making the process completely portable. 140 FRAMING AND SUPPORT SYSTEMS AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL 141 AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL *These items require a separate M10X40 cone bolt Tel : 01642 217341 Fax: 01642 253723 em ai l : sales@bilcourt. co. uk • • • • • • • • • Cables & leads Cable management Heating & ventilation Distribution, switchgear & enclosures Lamps Lighting products Security & emergency Site equipment. tools & fixings Wiring accessories MEMBER offering a great deal more Middlesbrough Branch Milton Keynes Branch Warrington Branch Riverside Park Road, Middlesbrough, Cleveland TS2 1QW 7 Fitzhamon Court, Wolverton Mill South, Milton Keynes MK12 6LB Tel: Sales 01642 241133 / Admin 254234 Fax: Sales 01642 226171 / Admin 226474 Tel: 01908 221414 Fax: 01908 221661 2 Bishops Court, Calver Road, Winwick Quay, Warrington WA2 8QY Email: miltonkeynes@clevelandcable.com Tel: 01925 655383 Fax: 01925 655989 Email: warrington@clevelandcable.com Email: sales@clevelandcable.com Website: www.clevelandcable.com Bristol Branch London Branch Bilcourt Electrical Distributors Ltd St. Georges Industrial Estate, St. Andrews Road, Avonmouth, Bristol BS11 9HS Crabtree Manorway South, Belvedere, Kent DA17 6AB Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: 0208 311 4141 Fax: 0208 320 5454 Tel: 01642 217341 Fax: 01642 253723 Email: london@clevelandcable.com Email: sales@bilcourt.co.uk Glasgow Branch Newcastle Branch Aberdeen Office 56 Clydesmill Road, Cambuslang Investment Park, Cambuslang, Glasgow G32 8RE Fisher Street Industrial Estate, Walker, Newcastle Upon Tyne NE6 4LT Westhill Business Centre, Arnhall Business Park, Westhill, Aberdeen AB32 6UF Tel: 0191 2633363 Fax: 0191 2630601 Tel: Sales 01224 330565 Fax: Sales 01224 330564 Tel: 01179 382222 Fax: 01179 382220 Email: bristol@clevelandcable.com Tel: 0141 646 5000 Fax: 0141 646 5001 Email: glasgow@clevelandcable.com Email: newcastle@clevelandcable.com